CABLEADO ESTRUCTURADO
Ing. Jos Joskowicz Instituto de Ingeniera Elctrica, Facultad de Ingeniera Universidad de la Repblica Montevideo, URUGUAY Octubre 2008 Versin 8
Cableado Estructurado
Pgina 1
Redes Corporativas
Temario
Temario ................................................................................................................... 2 1 Introduccin...................................................................................................... 5 2 ANSI/TIA/EIA-569 Espacios y canalizaciones para telecomunicaciones en edificios comerciales ............................................................................................... 6 2.1 2.2 2.3 2.4 Introduccin .............................................................................................. 6 Instalaciones de Entrada........................................................................... 8 Sala de Equipos ........................................................................................ 8 Canalizaciones de Back-Bone................................................................ 9 Canalizaciones externas entre edificios............................................. 9 Canalizaciones Subterrneas ..................................................... 9 Canalizaciones directamente enterradas.................................... 9 Backbone areos........................................................................ 9 Canalizaciones en tneles ........................................................ 10 Canalizaciones montantes verticales........................................ 10 Canalizaciones montantes horizontales ................................... 10 2.4.1.1 2.4.1.2 2.4.1.3 2.4.1.4 2.4.2 2.4.2.1 2.4.2.2 2.5 2.6
2.4.1
Canalizaciones internas................................................................... 10
Salas de Telecomunicaciones ................................................................ 11 Canalizaciones horizontales ................................................................... 12 Tipos de Canalizaciones.................................................................. 13 Secciones de las canalizaciones ..................................................... 16 Distancias a cables de energa ........................................................ 17
reas de trabajo...................................................................................... 18
3 ANSI/J-STD-607 Tierras y aterramientos para los sistemas de telecomunicaciones de edificios comerciales ........................................................ 19 3.1 3.2 3.3 3.4 Introduccin ............................................................................................ 19 TMGB (Barra principal de tierra para telecomunicaciones)..................... 19 TGB (Barras de tierra para telecomunicaciones) .................................... 21 TBB (Backbone de tierras)...................................................................... 21
4 ANSI/TIA/EIA-568 Cableado de telecomunicaciones para edificios comerciales ........................................................................................................... 22 4.1 4.2 Introduccin ............................................................................................ 22 ANSI/TIA/EIA 568-B.1............................................................................. 26 Instalaciones de Entrada ................................................................. 26
4.2.1
Cableado Estructurado
Pgina 2
Redes Corporativas 4.2.2 Distribuidor o repartidor principal y secundarios (Main / Intermediate Cross-Connect) .............................................................................................. 26 4.2.3 4.2.4 4.2.5 4.2.6 Distribucin central de cableado (Back-bone distribution)............. 28 Distribuidores o repartidores Horizontales (Horizontal Corss-Connect) 30 Distribucin Horizontal de cableado (Horizontal Distribution) .......... 32 Cableado Horizontal en oficinas abiertas ...................................... 33
4.2.6.1 Dispositivos de mltiples conectores de telecomunicaciones (Multi-User Telecommunications Outlet Assembly).................................. 34 4.2.6.2 4.2.7 Puntos de Consolidacin .......................................................... 35 reas de Trabajo ............................................................................. 37
4.3 ANSI/TIA/EIA 568-B.2: Balanced Twisted-Pair Cabling Components (Componentes de cableados UTP).................................................................... 39 4.3.1 4.3.2 4.3.3 Caractersticas mecnicas de los cables para cableado horizontal . 40 Caractersticas elctricas de los cables para cableado horizontal ... 41 Caractersticas de transmisin de los cables para cableado horizontal 41 Atenuacin................................................................................ 41 Prdida por Retorno ................................................................. 42 Diafona (Cross-talk) .............................................................. 45 ACR (Atenuation Crosstalk Ratio) ............................................ 49 Retardo de propagacin ........................................................... 51 Diferencias de Retardo de propagacin (Delay Skew) ............. 51
4.4 ANSI/TIA/EIA 568-B.3 Optical Fiber Cabling Components (Componentes de cableado de Fibra ptica)............................................................................. 52 4.4.1 Introduccin a las fibras pticas....................................................... 52 Evolucin de la transmisin ptica............................................ 52 Sistemas de fibra ptica ........................................................... 54 Factores que afectan la perfomance de los sistemas pticos... 59 Construccin de cables de fibras pticas ................................. 60 4.4.1.1 4.4.1.2 4.4.1.3 4.4.1.4 4.4.2 4.4.3 4.4.4 4.4.5 5 5.1
Cableado Estructurado
Pgina 3
Redes Corporativas 5.2 5.3 5.4 5.5 6 7 Seleccin del proveedor.......................................................................... 65 Ejecucin ................................................................................................ 66 Certificacin ............................................................................................ 66 Mantenimiento ........................................................................................ 68
Cableado Estructurado
Pgina 4
Redes Corporativas
1 Introduccin
Hasta 1985 no existan estndares para realizar cableados para los sistemas de telecomunicaciones corporativos. Cada sistema tena sus propios requerimientos acerca de las caractersticas del cableado que necesitaban. Los sistemas telefnicos requeran tpicamente cables multipares, con requerimientos elctricos y mecnicos acordes a las seales telefnicas. Los equipos informticos (por esa poca generalmente Main-Frames con terminales) requeran cableados con caractersticas especiales, dependientes de la marca de los equipos que usaban. Generalmente los propios fabricantes de Main-Frames provean tambin el cableado necesario para su conexin a los terminales. En esa poca no era extrao encontrar en una misma instalacin par trenzado para el servicio telefnico, multipar trenzado blindado para las terminales del mini-computador, coaxial para la naciente red de PCs, twin-axial para las terminales del computador central, coaxial para el circuito cerrado de vigilancia por TV, etc. A medida que las tecnologas de los sistemas de informacin comenzaron a madurar, ms y ms organizaciones y empresas comenzaron a requerir de estos sistemas, cada uno de los que requera de su tipo de cable, conectores, y prcticas de instalacin. Con cada cambio tecnolgico en los sistemas de informacin tambin era necesario cambiar el cableado. En 1985, la CCIA (Computer Communications Industry Association) solicit a la EIA (Electronic Industries Alliance) realizar un estndar referente a los sistemas de cableado. En esa fecha se entendi que era necesario realizar un estndar que contemplara todos los requerimientos de cableado de los sistemas de comunicaciones, incluyendo voz y datos, para el rea corporativa (empresarial) y residencial. La EIA asign la tarea de desarrollar estndares de cableado al comit TR-41. El foco principal del comit al desarrollar estos estndares consisti en asegurarse de que eran independientes tanto de las tecnologas de los sistemas de comunicaciones como de los fabricantes. El resultado de este esfuerzo, llevado a cabo desde 1985 hasta el da de hoy, ha sido la realizacin y aceptacin de un conjunto de recomendaciones (llamadas estndares) acerca de las infraestructuras de cableado para los edificios comerciales y residenciales. En esta instancia, se estudiarn los siguientes estndares de infraestructura de cableado: ANSI/TIA/EIA-569 Commercial Building Standards for Telecommunications Pathways and Spaces. ANSI/J-STD-607 Grounding and Bonding Telecommunications in Commercial Buildings. Requirements for
Cableado Estructurado
Pgina 5
Redes Corporativas
Desde Octubre de 2004 est vigente la revision B de la recomendacin, conocida como ANSI/TIA/EIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces, Este estndar tiene en cuenta tres conceptos fundamentales relacionados con telecomunicaciones y edificios: Los edificios son dinmicos. Durante la existencia de un edificio, las remodelaciones son comunes, y deben ser tenidas en cuentas desde el momento del diseo. Este estndar reconoce que existirn cambios y los tiene en cuenta en sus recomendaciones para el diseo de las canalizaciones de telecomunicaciones. Los sistemas de telecomunicaciones son dinmicos. Durante la existencia de un edificio, las tecnologas y los equipos de telecomunicaciones pueden cambian dramticamente. Este estndar reconoce este hecho siendo tan independiente como sea posible de proveedores y tecnologas de equipo.
Cableado Estructurado
Pgina 6
Redes Corporativas Telecomunicaciones es ms que voz y datos. El concepto de Telecomunicaciones tambin incorpora otros sistemas tales como control ambiental, seguridad, audio, televisin, alarmas y sonido. De hecho, telecomunicaciones incorpora todos los sistemas que transportan informacin en los edificios.
Es de fundamental importancia entender que para que un edificio quede exitosamente diseado, construido y equipado para soportar los requerimientos actuales y futuros de los sistemas de telecomunicaciones, es necesario que el diseo de las telecomunicaciones se incorpore durante la fase preliminar de diseo arquitectnico. El estndar identifica seis componentes en la infraestructura edilicia: Instalaciones de Entrada Sala de Equipos Canalizaciones de Montantes (Back-bone) Salas de Telecomunicaciones Canalizaciones horizontales reas de trabajo
Cableado Estructurado
Pgina 7
Redes Corporativas
Cableado Estructurado
Pgina 8
Redes Corporativas o Vibraciones o Altura adecuada o Iluminacin o Consumo elctrico o Prevencin de incendios o Aterramientos
Cableado Estructurado
Pgina 9
Redes Corporativas Protecciones mecnicas, carga sobre los puntos de fijacin, incluyendo tormentas y vientos
2.4.1.4 Canalizaciones en tneles La ubicacin de las canalizaciones dentro de tneles debe ser planificada de manera que permita el correcto acceso al personal de mantenimiento, y tambin la separacin necesaria con otros servicios. 2.4.2 Canalizaciones internas Las canalizaciones internas de backbone, generalmente llamadas montantes son las que vinculan las instalaciones de entrada con la sala de equipos, y la sala de equipos con las salas de telecomunicaciones. Estas canalizaciones pueden ser ductos, bandejas, escalerillas portacables, etc. Es muy importante que estas canalizaciones tengan los elementos cortafuegos de acuerdo a las normas corporativas y/o legales. Las canalizaciones montantes pueden ser fsicamente verticales u horizontales. 2.4.2.1 Canalizaciones montantes verticales Se requieren para unir la sala de equipos con las salas de telecomunicaciones o las instalaciones de entrada con la sala de equipos en edificios de varios pisos. Generalmente, en edificios de varios pisos, las salas de telecomunicaciones se encuentran alineados verticalmente, y una canalizacin vertical pasa por cada piso, desde la sala de equipos. Estas canalizaciones pueden ser realizadas con ductos, bandejas verticales, o escalerillas portacables verticales. No se admite el uso de los ductos de los ascensores para transportar los cables de telecomunicaciones. 2.4.2.2 Canalizaciones montantes horizontales Si las salas de telecomunicaciones no estn alineadas verticalmente, son necesarios tramos de montantes horizontales. Estas canalizaciones pueden ser realizadas con ductos, bandejas horizontales, o escalerillas portacables. Pueden ser ubicadas sobre el cielorraso, debajo del piso, o adosadas a las paredes.
Cableado Estructurado
Pgina 10
Redes Corporativas
Si es necesario disponer de ms de una sala de telecomunicaciones en un mismo piso, se recomienda interconectarlas con canalizaciones del tipo montante. Los tamaos recomendados para las salas de telecomunicaciones son las siguientes (se asume un rea de trabajo por cada 10 m2): rea utilizable 500 m2 800 m 1.000 m La figura muestra una recomendaciones TIA-569
2 2
Tamao recomendado de la sala de telecomunicaciones 3 m x 2.2 m 3 m x 2.8 m 3 m x 3.4 m de telecomunicaciones tpica segn las
sala
Cableado Estructurado
Pgina 11
Redes Corporativas
Las salas de telecomunicaciones deben estar apropiadamente iluminadas. Se recomienda que el piso, las paredes y el techo sean de colores claros (preferiblemente blancos), para mejorar la iluminacin. No debe tener cielorraso. Es recomendable disponer de sobre piso, o piso elevado. Se deben tener en cuenta los requerimientos elctricos de los equipos de telecomunicaciones que se instalarn en estas salas. En algunos casos, es recomendable disponer de paneles elctricos propios para las salas de telecomunicaciones. Todas los accesos de las canalizaciones a las salas de telecomunicaciones deben estar selladas con los materiales antifuego adecuados. Es recomendable disponer de ventilacin y/o aires acondicionados de acuerdo a las caractersticas de los equipos que se instalarn en estas salas.
Cableado Estructurado
Pgina 12
Redes Corporativas 2.6.1 Tipos de Canalizaciones El estndar TIA-569 admite los siguientes tipos de canalizaciones horizontales: Ductos bajo piso
En estos casos los ductos son parte de la obra civil. Bajo el piso se puede realizar una malla de ductos, disponiendo de lneas determinadas para telecomunicaciones, energa, etc. En las reas de trabajo se dispone de puntos de acceso a los ductos bajo piso, utilizando torretas, periscopios u otro tipo de accesorios. Como regla general, debe preverse una seccin de 650 mm2 por cada rea de trabajo de 3 puestos que alimente el ducto. Ductos bajo piso elevado
Los pisos elevados consisten en un sistema de soportes sobre el que apoyan lozas generalmente cuadradas. Son generalmente utilizados en
Cableado Estructurado
Pgina 13
Redes Corporativas salas de equipos y salas de telecomunicaciones. Sin embargo pueden ser tambin utilizados para oficinas. Debajo de este sistema de soportes puede ser instalado un sistema de ductos para cableado de telecomunicaciones, de energa, etc. No se recomienda tender cables sueltos debajo del piso elevado. Las lozas de los pisos elevados deben ser perforadas en los lugares correspondientes a las reas de trabajo, y sobre stas perforaciones se deben ubicar torretas u otro tipo de accesorios adecuados para la terminacin de los cables. Existen varios tipos de estos accesorios, algunos de los cuales quedan a ras del piso. Ductos aparentes
Los ductos aparentes pueden ser metlicos o de PVC, rgidos en ambos casos. No se recomiendan ductos flexibles para las canalizaciones horizontales. Las caractersticas de estos ductos y de su instalacin deben ser acordes a los requisitos arquitectnicos y edilicios. Se recomienda que no existan tramos mayores a 30 metros sin puntos de registro e inspeccin, y que no existan ms de dos quiebres de 90 grados en cada tramo.
Cableado Estructurado
Pgina 14
Las bandejas portacables consisten en estructuras rgidas, metlicas o de PVC, generalmente de seccin rectangular (en forma de U). La base y las paredes laterales pueden ser slidas o caladas. Las bandejas de este tipo pueden o no tener tapa. Las bandejas se instalan generalmente sobre el cielorraso, aunque pueden ser instaladas debajo del cielorraso, o adosadas a las paredes.
Ductos sobre cielorraso Ductos sobre los cielorrasos pueden ser utilizados, siempre y cuando su acceso sea sencillo, por ejemplo, removiendo planchas livianas de cielorraso. Los ductos o bandejas sobre cielorraso deben estar adecuadamente fijados al techo, por medio de colgantes. No se recomienda que estn directamente apoyadas sobre la estructura propia del cielorraso. Los cables sobre cielorraso no pueden estar sueltos, apoyados directamente sobre el cielorraso, sino que deben estar dentro de ductos o bandejas.
Cableado Estructurado
Pgina 15
Redes Corporativas
Ductos perimetrales
Los ductos perimetrales pueden ser usados para llegar con el cableado horizontal hasta las reas de trabajo, en caso de oficinas cerradas o tipo boxes. 2.6.2 Secciones de las canalizaciones Las secciones de las canalizaciones horizontales dependen de la cantidad de cables que deben alojar y del dimetro externo de los mismos. En el diseo se debe recordar que cada rea de trabajo debe disponer por lo menos de dos cables UTP (tpicamente de dimetro entre 4.5 y 5.5 mm). Asimismo se debe tener en cuenta el crecimiento futuro, dejando espacio en las canalizaciones para cables adicionales. En la siguiente tabla se pueden calcular las secciones de canalizaciones necesarias en funcin de la cantidad de cables y su dimetro, para un factor de llenado estndar. Las celdas de fondo blanco indican la cantidad de cables.
Dimetro interno de la canalizacin Denominacin del ducto (mm) 15,8 20,9 (pulgadas) 1/2 3/4 3,3 1 6 4,6 1 5 5,6 0 4 6,1 0 3 7,4 0 2
Cableado Estructurado
Pgina 16
Redes Corporativas
Dimetro interno de la canalizacin Denominacin del ducto (mm) 26,6 35,1 40,9 52,5 62,7 77,9 (pulgadas) 1 1 1/4 1 1/2 2 2 1/2 3 3,3 8 16 20 30 45 70 4,6 8 14 18 26 40 60 5,6 7 12 16 22 36 50 6,1 6 10 15 20 30 40 7,4 3 6 7 14 17 20
2.6.3 Distancias a cables de energa Las canalizaciones para los cables de telecomunicaciones deben estar adecuadamente distanciadas de las canalizaciones para los cables de energa. Las distancias mnimas se indican en la siguiente tabla. Las celdas en fondo blanco indican la separacin mnima
Potencia < 2 kVA Lneas de potencia no blindadas, o equipos elctricos prximos a canalizaciones no metlicas Lneas de potencia no blindadas, o equipos elctricos prximos a canalizaciones metlicas aterradas Lneas de potencia en canalizaciones metlicas aterradas prximos a canalizaciones metlicas aterradas 2 - 5 kVA > 5 kVA
127 mm
305 mm
610 mm
64 mm
152 mm
305 mm
76 mm
152 mm
Cableado Estructurado
Pgina 17
Redes Corporativas
Cableado Estructurado
Pgina 18
Redes Corporativas
de
En octubre de 2002 ha sido publicado el estndar ANSI/J-STD--607-A-2002. El propsito de este documento es brindar los criterios de diseo e instalacin de las tierras y el sistema de aterramiento para edificios comerciales, con o sin conocimiento previo acerca de los sistemas de telecomunicaciones que sern instalados. Este estndar incluye tambin recomendaciones acerca de las tierras y los sistemas de aterramientos para las torres y las antenas. Asimismo, el estndar prev edificios compartidos por varias empresas, y ambientes con diversidad de productos de telecomunicaciones. Este nuevo estndar se basa en el ANSI/TIA/EIA-607 publicado en Agosto de 1994, y lo actualiza, incluyendo criterios de aterramientos para torres y antenas, tablas para el clculo del dimetro de conductores y barras de aterramiento, etc.
Cableado Estructurado
Pgina 19
Redes Corporativas AWG mm mm2). Asimismo, debe estar correctamente identificado mediante etiquetas adecuadas. Es recomendable que el conductor de tierra de telecomunicaciones no sea ubicado dentro de canalizaciones metlicas. En caso de tener que alojarse dentro de canalizaciones metlicas, stas deben estar elctricamente conectadas al conductor de tierra en ambos extremos. La TMGB (Telecomunications Main Grounding Busbar) es el punto central de tierra para los sistemas de telecomunicaciones. Se ubica en las Instalaciones de Entrada, o en la Sala de Equipos. Tpicamente hay una nica TMGB por edificio, y debe ser ubicada de manera de minimizar la distancia del conductor de tierra hasta el punto de aterramiento principal del edificio.
La TMGB debe ser una barra de cobre, con perforaciones roscadas segn el estndar NEMA. Debe tener como mnimo 6 mm de espesor, 100 mm de ancho y largo adecuado para la cantidad de perforaciones roscadas necesarias para alojar a todos los cables que lleguen desde las otras barras de tierra de
Cableado Estructurado
Pgina 20
Redes Corporativas telecomunicaciones. Deben considerarse perforaciones para los cables necesarios en el momento del diseo y para futuros crecimientos.
Cableado Estructurado
Pgina 21
Redes Corporativas
para
edificios
El estndar ANSI/TIA/EIA-568 y sus recientes actualizaciones especifican los requerimientos de un sistema integral de cableado, independiente de las aplicaciones y de los proveedores, para los edificios comerciales. Se estima que la vida productiva de un sistema de cableado para edificios comerciales debe ser de 15 a 25 aos. En este perodo, las tecnologas de telecomunicaciones seguramente cambien varias veces. Es por esto que el diseo del cableado debe prever grandes anchos de banda, y ser adecuado tanto a las tecnologas actuales como a las futuras. El estndar especifica: Requerimientos mnimos para cableado de telecomunicaciones dentro de un ambiente de oficina, para distintas tecnologas de cables (cobre y fibra). Topologa y distancias recomendadas. Parmetros de desempeo de los medios de comunicacin (cables de cobre, fibra).
Este estndar ha tenido las siguientes versiones ANSI/TIA/EIA 568-A Commercial Standard. (Octubre 1995) Building Telecommunications Cabling
ANSI/TIA/EIA 568-A-1 Propagation Delay and Delay Skew Specifications for 100 ohm 4-pair Cable. (Setiembre 1997) ANSI/TIA/EIA 568-A-2 Corrections and Additions to TIA/EIA-568-A. (Agosto 1998) ANSI/TIA/EIA 568-A-3 Hybrid Cables. (Diciembre 1998) ANSI/TIA/EIA 568-A-4 Production Modular Cord NEXT Loss Test Meted and Requirements for UTP Cabling. (Diciembre 1999) ANSI/TIA/EIA 568-A-5 Transmissoin Performance Specifications for 4-pair 100 ohm Category 5e Cabling. (Enero 2000)
ANSI/TIA/EIA 568-B.1 Commercial Building Telecommunications Cabling Standard, Part 1: General Requirements. (Abril 2001) ANSI/TIA/EIA 568-B.1-1 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 1 - Minimum 4-Pair UTP and 4-Pair ScTP Patch Cable Bend Radius (Mayo 2001)
Cableado Estructurado
Pgina 22
Redes Corporativas ANSI/TIA/EIA 568-B.1-2 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 2 - Grounding and Bonding Requirements for Screened Balanced Twisted-Pair Horizontal Cabling (Febrero 2003) ANSI/TIA/EIA 568-B.1-3 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 3 - Supportable Distances and Channel Attenuation for Optical Fiber Applications by Fiber Type (Febrero 2003) ANSI/TIA/EIA 568-B.1-4 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 4 - Recognition of Category 6 and 850 nm Laser-Optimized 50/125 m Multimode Optical Fiber Cabling (Febrero 2003) ANSI/TIA/EIA 568-B.1-5 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 5 - Telecommunications Cabling for Telecommunications Enclosures (Marzo 2004) ANSI/TIA/EIA 568-B.1-7 Telecommunications Cabling Standard, Part 1: General Requirements - Addendum 7 - Guidelines for Maintaining Polarity Using Array Connectors (Enero 2006)
ANSI/TIA/EIA 568-B.2 Commercial Building Telecommunications Cabling Standard - Part 2: Balanced Twisted Pair Cabling Components (Mayo 2001) ANSI/TIA/EIA 568-B.2-1 Commercial Building Telecommunications Cabling Standard, Part 2 Addendum 1 - Transmission Performance Specifications for 4-Pair 100 Ohm Category 6 Cabling (Junio 2002) ANSI/TIA/EIA 568-B.2-2 Commercial Building Telecommunications Cabling Standard - Part 2: Balanced Twisted-Pair Cabling Components - Addendum 2 (Diciembre 2001) ANSI/TIA/EIA 568-B.2-3 Commercial Building Telecommunications Cabling Standard - Part 2: Balanced Twisted-Pair Cabling - Addendum 3 - Additional Considerations for Insertion Loss and Return Loss Pass/Fail Determination (Marzo 2002) ANSI/TIA/EIA 568-B.2-4 Commercial Building Telecommmications Cabling Standard - Part 2: Balanced Twisted Pair Components - Addendum 4 Solderless Connection Reliability Requirements for Copper Connecting Hardware (Junio 2002) ANSI/TIA/EIA 568-B.2-5 Commercial Building Telecommmications Cabling Standard - Part 2: Balanced Twisted Pair Components - Addendum 5 Corrections to TIA/EIA-568-B.2 (Enero 2003) ANSI/TIA/EIA 568-B.2-6 Commercial Building Telecommmications Cabling Standard - Part 2: Balanced Twisted Pair Components - Addendum 6 Category 6 Related Component Test Procedures (Diciembre 2003)
Cableado Estructurado
Pgina 23
Redes Corporativas ANSI/TIA/EIA 568-B.2-7 Commericial Building Telecommunications Cabling Standards Part 2 - Balanced Twisted Pair Cabling Components Addendum 7 - Reliability Requirements for Connecting Hardware used in Balanced Twisted-Pair Cabling (Agosto 2007) ANSI/TIA/EIA 568-B.2-10 Transmission Performance Specifications for 4Pair 100 Ohm Augmented Category 6 Cabling (Marzo 2008) ANSI/TIA/EIA 568-B.2-11 Commercial Building Telecommmications Cabling Standard - Part 2: Balanced Twisted Pair Components - Addendum 11 Specification for Increased Diameter of 4-Pair UTP and SCTP Cable (Diciembre 2005)
ANSI/TIA/EIA 568-B.3 Optical Fiber Cabling Components. (Abril 2000) ANSI/TIA/EIA 568-B.3-1 Optical Fiber Cabling Components Standard Addendum 1 - Additional Transmission Performance Specifications for 50/125 um Optical Fiber Cables (Abril 2002)
El ltimo estndar publicado por la TIA es el ANSI/TIA/EIA 568-B. Es una revisin del ANSI/TIA/EIA 568-A, publicado originalmente en 1995. El nuevo estndar incluye el documento central del original y los adendum (TSB-67, TSB-72, TSB75 y TSB-95) [1]. Est armado en 3 partes: ANSI/TIA/EIA 568-B.1 indica los requerimientos generales. Provee informacin acerca del planeamiento, instalacin y verificacin de cableados estructurados para edificios comerciales. Establece parmetros de desempeo de los cableados. Uno de los mayores cambios de este documento, es que reconoce nicamente la categora 5e o superiores. ANSI/TIA/EIA 568-B.2 detalla los requerimientos especficos de los cables de pares trenzados balanceados, a nivel de sus componentes y de sus parmetros de transmisin ANSI/TIA/EIA 568-B.3 especifica los componentes de fibra ptica admitidos para cableados estructurados.
Cableado Estructurado
Pgina 24
Redes Corporativas
Cableado Estructurado
Pgina 25
Redes Corporativas
4.2.1 Instalaciones de Entrada Se corresponde con la definicin del estndar TIA-569. Ver 2.2. Se define como el lugar en el que ingresan los servicios de telecomunicaciones al edificio y/o dnde llegan las canalizaciones de interconexin con otros edificios de la misma corporacin (por ejemplo, si se trata de un campus). Las instalaciones de entrada pueden contener dispositivos de interfaz con las redes publicas prestadoras de servicios de telecomunicaciones, y tambin equipos de telecomunicaciones. Estas interfaces pueden incluir borneras (por ejemplo telefnicas) y equipos activos (por ejemplo modems). El Punto de demarcacin, lmite de responsabilidades entre los prestadores de servicio y las empresas que ocupan el edificio, se encuentra tpicamente en esta sala. Estos puntos de demarcacin pueden ser las borneras de terminacin del cableado de planta externa, o equipos activos (por ejemplo mdems HDSL). En ste ltimo caso, estos equipos activos provistos por los prestadores de servicios tambin pueden ubicarse en las Sala de Equipos. (Ver 2.3) 4.2.2 Distribuidor o repartidor principal y secundarios (Main / Intermediate Cross-Connect) La estructura general del cableado se basa en una distribucin jerrquica del tipo estrella, con no ms de 2 niveles de interconexin. El cableado hacia las reas de trabajo parte de un punto central, generalmente la Sala de Equipos. Aqu se ubica el Distribuidor o Repartidor principal de cableado del edificio. Partiendo de ste distribuidor principal, para llegar hasta las reas de trabajo, el cableado puede pasar por un Distribuidor o Repartidor secundario y por una Sala de Telecomunicaciones.
Cableado Estructurado
Pgina 26
Redes Corporativas El estndar no admite ms de dos niveles de interconexin, desde la sala de equipos hasta la sala de Telecomunicaciones. Estos dos niveles de interconexin brindan suficiente flexibilidad a los cableados de back-bone.
Sala de Equipos
Distribuidor Principal
Sala de Telecomunicaciones
Distribuidor Secundario
BackBone
Sala de Telecomunicaciones
Sala de Telecomunicaciones
rea de Trabajo
rea de Trabajo
rea de Trabajo
Cableado Horizontal
rea de Trabajo
rea de Trabajo
El Distribuidor o repartidor principal de cableado se encuentra tpicamente en la Sala de Equipos (Ver 2.3). A este repartidor llegan los cables de los equipos comunes al edificio (PBX, Servidores centrales, etc.) y son cruzados hacia los cables de distribucin central (cables montantes o de Back-Bone). El distribuidor o repartidor principal (a veces llamado MDF = Main Distributoin Frame) puede estar constituido por regletas, patcheras u otros elementos de interconexin. Generalmente est dividido en dos reas, una a la que llegan los cables desde los equipos centrales (por ejemplo PBX) y otra a la que llegan los cables de distribucin central (back-bone).
Cableado Estructurado
Pgina 27
Redes Corporativas
Main Cross-Connect
Cables hacia los equipos (por ejemplo PBX)
En la figura se muestra un distribuidor principal realizado con regletas, al que llegan los cables desde los equipos centrales (por ejemplo, desde una PBX) y del que salen los cables montantes o cables de back-bone. 4.2.3 Distribucin central de cableado (Back-bone distribution) La funcin del back-bone es proveer interconexin entre los armarios de telecomunicaciones y las salas de equipos y entre las salas de equipos y las instalaciones de entrada. Los sistemas de distribucin central de cableado incluyen los siguientes componentes: Cables montantes Repartidores principales y secundarios Terminaciones mecnicas Cordones de interconexin o cables de cruzadas para realizar las conexiones entre distintos cables montantes
Cableado Estructurado
Pgina 28
Redes Corporativas El diseo de los sistemas de distribucin central de cableado deben tener en cuenta las necesidades inmediatas y prever las posibles ampliaciones futuras, reservando lugar en el diseo de las canalizaciones, previendo cables con la cantidad adecuada de conductores, diseando la cantidad de regletas o elementos de interconexin en los repartidores principales e intermedios, etc. El esquema de la distribucin central de cableado debe seguir la jerarqua en forma de estrella indicada en 4.2.2 , de manera de no tener ms de 2 puntos de interconexin desde los equipos hasta los puntos de interconexin horizontal (Armario de Telecomunicaciones). El estndar admite los siguientes cables para el Back-Bone: Cables UTP de 100 ohm (par trenzado sin malla) Cables de Fibra ptica multimodo de 50/125 m Cables de Fibra tpica multimodo de 62.5/125 m Cables de Fibra tpica monomodo Cable STP-A de 150 ohm (par trenzado con malla).
Los cables coaxiales, ya no estn admitidos en el estndar. El cable STP-A de 150 ohm, si bien es admitido, no se recomienda para instalaciones nuevas. La eleccin del tipo de cable y la cantidad de pares a utilizar depende de los servicios existentes y los futuros previstos. Para servicios telefnicos clsicos, se debe disponer de cables de cobre (UTP), a razn de un par por cada servicio telefnico (interno, fax, MODEM, etc.). Los servicios telefnicos comunes necesitan tpicamente de un par para funcionar, mientras que servicios especiales pueden requerir de dos o ms pares (por ejemplo, telfonos con ampliaciones de botoneras, consolas de telefonista, etc.). Asimismo, algunas PBX que disponen de telfonos hbridos requieren de 2 pares por cada uno de stos telfonos. Es recomendable prever un crecimiento de por lo menos un 50% respecto a la cantidad de cables necesarias inicialmente. A diferencia de los servicios telefnicos clsicos, los servicios de datos (o de telefona IP) generalmente no requieren de pares de cobre desde la sala de equipos. Este tipo de servicios generalmente puede soportarse mediante el tendido de Fibras pticas, desde la sala de equipos (o centro de cmputos) hasta los armarios de telecomunicaciones. Por esta razn, los tendidos de back-bone generalmente se componen de cables UTP y de cables de Fibras pticas, en nmero apropiada para las necesidades presentes y previsiones futuras. Las distancias mximas para los cables montantes dependen de las aplicaciones (telefona, datos, video, etc.) que deban transmitirse por ellas. Como reglas generales, el estndar establece las distancias mximas presentadas a continuacin:
Cableado Estructurado
Pgina 29
Redes Corporativas
Tipo de Cable
Sala de Sala de Distribuidor Telecomunicaciones Telecomunicaciones Secundario hasta hasta Distribuidor hasta Distribuidor Distribuidor Principal Secundario Principal
UTP
800 m
300 m
500 m
2.000 m 3.000 m
300 m 300 m
1.700 m 2.700 m
Es de hacer notar que no todas las aplicaciones podrn funcionar adecuadamente con estas distancias mximas. Por ejemplo, si se pretende tener transmisin de datos sobre UTP en el back-bone, la distancia mxima para su correcto funcionamiento ser de 90 m (y no 800 m como indica el mximo del estndar). 4.2.4 Distribuidores o repartidores Horizontales (Horizontal Corss-Connect) Los cables montantes (back-bone) terminan en los distribuidores o repartidores horizontales, ubicados en la Sala de Telecomunicaciones. Estos repartidores horizontales deben disponer de los elementos de interconexin adecuados para la terminacin de los cables montantes (ya sean de cobre o fibra ptica). Asimismo, a los repartidores horizontales llegan los cables provenientes de las reas de trabajo (cableado horizontal, de all su nombre de repartidores horizontales), el que tambin debe ser terminado en elementos de interconexin adecuado. La funcin principal de los repartidores horizontales es la de interconectar los cables horizontales (provenientes de las reas de trabajo) con los cables montantes (provenientes de la sala de equipos). Eventualmente, en la Sala de Telecomunicaciones, puede haber equipos de telecomunicaciones, los que son incorporados al repartidor horizontal para su interconexin hacia la sala de equipos (a travs del back-bone) y/o hacia las reas de trabajo (a travs del cableado horizontal).
Cableado Estructurado
Pgina 30
Redes Corporativas
Cables montantes Paneles de interconexin con Back-Bone (Back-bone) Cableado Horizontal
Sala de Telecomunicaciones
Area de
Equipos activos de Telecomunicaciones
Trabajo
Tpicamente los repartidores horizontales, ubicados en las salas de telecomunicaciones, consisten en paneles de interconexin, en los que terminan los cableados horizontales y los cableados de backbone. Estos paneles de interconexin permiten, mediante el uso de cables de interconexin, conectar cualquier cable horizontal con cualquier cable de backbone o equipo activo. Los paneles de interconexin pueden ser patcheras con conectores del tipo RJ45 o regletas de diversos formatos. Sin embargo, estos paneles deben cumplir con las caractersticas mecnicas y elctricas que se especifican en los estndares de acuerdo a la categora (5e, 6, etc.) del sistema. De la misma manera, los cables de interconexin (generalmente llamados patch cords o cordones de patcheo) tambin deben cumplir con las caractersticas mecnicas y elctricas de acuerdo a su categora. En el caso de disponer de equipos activos en el armario de telecomunicaciones (tpicamente hubs, switches, etc.), se admite conectar directamente los paneles del cableado horizontal a los equipos activos, mediante cables de interconexin adecuados (por ejemplo cordones de patcheo).
Cableado Estructurado
Pgina 31
Redes Corporativas 4.2.5 Distribucin Horizontal de cableado (Horizontal Distribution) La distribucin horizontal es la parte del cableado de telecomunicaciones que conecta las reas de trabajo con los distribuidores o repartidores horizontales, ubicados en el Armario o Sala de Telecomunicaciones. La distribucin horizontal incluye: Cables de distribucin horizontal Conectores de telecomunicaciones en las reas de trabajo (dnde son terminados los cables de distribucin horizontal) Terminaciones mecnicas de los cables horizontales Cordones de interconexin (Patch-cords) en el Armario o Sala de Telecomunicaciones. Puede incluir tambin Puntos de Consolidacin
El cableado de distribucin horizontal debe seguir una topologa del tipo estrella, con el centro en el armario o sala de telecomunicaciones, y los extremos en cada una de las reas de trabajo. Los conectores de telecomunicaciones en las reas de trabajo deben ser conectados mediante un cable directamente al panel de interconexin ubicado en el armario de telecomunicaciones. No se admiten empalmes ni uniones, salvo en caso de existir un punto de consolidacin (ver 4.2.6.2). La distancia mxima para el cable de distribucin horizontal es de 90 m, medida en el recorrido del cable, desde el conector de telecomunicaciones en el rea de trabajo hasta el panel de interconexin en el armario de telecomunicaciones. Los cordones de interconexin (patch-cords) utilizados en las reas de trabajo y en el armario de telecomunicaciones no deben ser ms largos que 10 m en conjunto (completando una distancia de 100 m de punta a punta. Se recomienda que los cordones de interconexin en cada extremo no superen los 5 m Los cables reconocidos para la distribucin horizontal son: UTP o ScTP de 100 y cuatro pares Fibra ptica multimodo de 50/125 m Fibra ptica multimodo de 62.5/125 m Cable STP-A de 150 . Este cable es an reconocido pero no recomendado para nuevas instalaciones.
Cada rea de trabajo debe estar equipada con un mnimo de 2 conectores de telecomunicaciones. Uno de ellos tpicamente es asociado con servicios de voz y el otro con servicios de datos, aunque esta distincin puede de hecho no existir. Uno de los conectores del rea de trabajo debe estar conectado a un cable UTP de 100 y cuatro pares, de categora 3 o superior, aunque para instalaciones nuevas se recomienda categora 5e o superior.
Cableado Estructurado
Pgina 32
Redes Corporativas El segundo de los conectores del rea de trabajo debe estar conectado a algunos de los siguientes tipos de cables: UTP de 100 y cuatro pares, de categora 5e o superior 2 cables de Fibra ptica multimodo de 50/125 m 2 cables de Fibra ptica multimodo de 62.5/125 m
En el diseo de cada instalacin se debe decidir la tecnologa ms conveniente para el cableado horizontal. Es muy comn en reas de oficinas utilizar nicamente cableado de cobre (UTP) para los 2 o ms conectores en las reas de trabajo. En este caso es altamente recomendable que todos ellos sean de categora 5e o superior, a pesar de que la norma admite que uno de ellos sea de categora inferior.
4.2.6 Cableado Horizontal en oficinas abiertas Como se describi en los captulos anteriores, el cableado horizontal consiste en tramos rgidos de cable, que comienzan en los armarios de telecomunicaciones y terminan en las reas de trabajo. Los puntos flexibles existen nicamente dentro de los armarios de telecomunicaciones (dnde puede interconectarse cualquier rea de trabajo a cualquier equipo o cable de backbone) y en las propias reas de trabajo (dnde mediante patch-cords pueden conectarse los PCs, telfonos, impresoras, etc.) Sin embargo, en varios edificios comerciales, las oficinas tienen cierta movilidad. Es comn encontrar oficinas del tipo boxes, dnde las divisiones son realizadas con componentes livianos (madera, yeso, tabiques, etc.). La disposicin de estas oficinas puede variar con el tiempo, de acuerdo a los nuevos requerimientos locativos de las empresas. Recordando que los sistemas de cableado estructurado estn pensados para una vida til de 15 a 25 aos, resulta claro que el cableado horizontal requiere de cierta movilidad que hasta ahora no ha sido contemplada. Es por esto que se ha incluido en la recomendacin la posibilidad de incluir dos tipos de sistemas que permiten cierta flexibilidad en el cableado horizontal:
Cableado Estructurado
Pgina 33
Redes Corporativas 4.2.6.1 Dispositivos de mltiples conectores de telecomunicaciones (Multi-User Telecommunications Outlet Assembly)
Los Dispositivos de mltiples conectores de telecomunicaciones son puntos de terminacin del cableado horizontal consistentes en varios conectores en una misma caja, tpicamente ubicada en puntos cercanos a varias reas de trabajo. Desde estos puntos, pueden tenderse cordones modulares (del tipo patch-cords) de hasta 20 m, los que deben ser conectados directamente a los equipos de las reas de trabajo. Los cables horizontales que parten del repartidor horizontal son terminado en forma fija (rgida) a los conectores ubicados en los Dispositivos de mltiples conectores de telecomunicaciones.
Estas cajas (Dispositivos de mltiples conectores de telecomunicaciones) deben ser ubicadas en lugares accesibles. No se admite que estn sobre el cielorraso. Cada uno de los cordones de interconexin que parten de estos puntos, hasta las reas de trabajo, deben estar debidamente etiquetados en ambas puntas, con identificadores nicos. Un mismo Dispositivo de mltiples conectores de telecomunicaciones puede tener hasta 12 conectores. Las distancias mximas desde los Dispositivo de mltiples conectores de telecomunicaciones hasta las reas de trabajo pueden variar, de acuerdo a las distancias de los cables horizontales que llegan a estos dispositivos, de manera
Cableado Estructurado
Pgina 34
Redes Corporativas que las distancia total (punta a punta) no supere los 100 m. La siguiente tabla indica las distancias mximas admisibles, en funcin de los tramos marcados como A, B y C en la figura anterior:
Tramo A (m) Tramo B (m) Tramo C (m) Distancia total (m)
5 5 5 5 5
90 85 80 75 70
5 9 13 17 22
100 99 98 97 97
En la caja que contiene a las mltiples conectores de telecomunicaciones debe indicarse claramente cual es la distancia mxima de los cables modulares de interconexin. 4.2.6.2 Puntos de Consolidacin
Los puntos de Consolidacin son lugares de interconexin entre cableado horizontal proveniente del repartidor horizontal y cableado horizontal que termina en las reas de trabajo o en los Dispositivo de mltiples conectores de telecomunicaciones. Dado que el cableado horizontal es rgido, la idea es tener un punto intermedio que permita, en caso de reubicaciones de oficinas (y por lo tanto de reas de trabajo), re-cablear nicamente parte del cableado horizontal (el que va desde el punto de consolidacin hasta las nuevas reas de trabajo). El punto de consolidacin no es un punto de interconexin flexible, sin un punto de interconexin rgido. Las reconexiones ocurren nicamente cuando se mueven las reas de trabajo y es necesario tender nuevos cables. En estos casos, en lugar de tender nuevos cables hasta los armarios de telecomunicaciones,
Cableado Estructurado
Pgina 35
Redes Corporativas pueden tenderse nuevos cables hasta los puntos de consolidacin, y mantener los cables desde estos puntos hasta los armarios de telecomunicaciones.
Como puede verse, los puntos de consolidacin son tiles para prever futuros cambios en los lugares de las reas de trabajo, pero no tan frecuentes como para que requieran de Dispositivos de mltiples conectores de telecomunicaciones. Cuando existen puntos de consolidacin, la distancia total de cable, desde el rea de trabajo, hasta el armario de telecomunicaciones (incluyendo el pasaje por el punto de consolidacin) no debe exceder los 90 m Se recomienda que los puntos de consolidacin, de ser necesarios, estn a ms de 15 m de la sala de telecomunicaciones, para evitar efectos adicionales que se pueden producir en tramos cortos de cables, producidos por rebotes en los puntos de interconexin. No se admite ms de un punto de consolidacin por cada cable horizontal. Un mismo punto de consolidacin puede servir hasta 12 reas de trabajo.
Cableado Estructurado
Pgina 36
Redes Corporativas 4.2.7 reas de Trabajo Las reas de trabajo incluyen los conectores de telecomunicaciones y los cordones de interconexin (Patch-cords) hasta el equipamiento (por ejemplo, PC, telfono, impresora, etc.). El tipo de equipamiento que se instale en las reas de trabajo no es parte de recomendacin. Se recomienda que la distancia del cordn de interconexin no supere los 5 m. Los cables UTP son terminados en los conectores de telecomunicaciones en jacks modulares de 8 contactos, en los que se admiten dos tipos de conexiones, llamados T568A y T568B. Esta denominacin no debe confundirse con el nombre de la norma ANSI/TIA/EIA 568-A o ANSI/TIA/EIA 568-B, ya que representan cosas bien diferentes. La norma actualmente vigente es la ANSI/TIA/EIA 568-B, en la que se admiten dos formas de conectar los cables en los conectores modulares. Estas dos formas de conexin son las que se denominan T568A y T568B. La siguiente figura indica la disposicin de cada uno de los hilos en un cable UTP, para ambos tipos de conexiones:
T568A
T568B
Cableado Estructurado
Pgina 37
Redes Corporativas
Los cables de fibra ptica son terminados en el rea de trabajo en conectores dobles, es decir, que permiten la terminacin de dos hilos de fibra.
Se recomienda utilizar el conector 568SC, pero se admiten otros tipos de conectores de dimensiones adecuadas. La figura muestra un conector del tipo 568SC y un cordn de interconexin de fibra ptica con su correspondiente terminacin 568SC
Cableado Estructurado
Pgina 38