EN 1057 - TYPE Y

Size

Nom. Dia.
(Outside)

(PREVIOUSLY BS 2871 TABLE Y)


Max. Working Pressures*

Nom. Wall
Thickness

Half Hard

mm

mm

mm

bar

6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108

6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108

0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.5
1.5
2.0
2.0
2.0
2.5

188
136
106
87
87
72
69
55
54
45
47
37
33
29

*Based on designated temper at 65C

Hard

bar+

223
161
126
104
104
85
84
65
65
54
56
45
39
34

144
105
82
67
67
55
53
42
41
34
36
28
25
22

bar

1 bar = 0.1N/mm = 10 5 N/m

ADDED
TOUGHNESS &
DURABILITY

Usage: Underground w orks and heav y duty requirements including hot and cold w ater
supply, gas reticulation, sanitary plumbing, heating and general engineering.

EN 1057 - TYPE X
Size

Nom. Dia.
(Outside)

(PREVIOUSLY BS 2871 TABLE X)


Max. Working Pressures*

Nom. Wall
Thickness

Half Hard

Hard

Annealed

bar+

bar+

161
118
93
76
71
67
62
48
51
43
33
27
29
20
17
18

102
75
59
48
45
43
39
31
33
27
21
17
18
13
10
12

mm

mm

mm

bar+

6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
133
159

6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
133
159

0.6
0.6
0.6
0.6
0.7
0.8
0.9
0.9
1.2
1.2
1.2
1.2
1.5
1.5
1.5
2.0

133
97
77
63
58
56
51
40
42
35
27
20
24
17
14
15

*Based on designated temper at 65C

Annealed

+1

bar = 0.1N/mm = 10 5 N/m

ECONOMICAL
AND
STRONG

Usage: Abov e groundserv ices including drinking w ater supply, hot and cold w ater systems,
sanitation, central heating and other general purpose applications.

EN 1057 - TYPE Z

(PREVIOUSLY BS 2871 TABLE X)

Size

Nom. Dia.
(Outside)

Nom. Wall
Thickness

Max. Working Pressures*

mm

mm

mm

bar+

6
8
10
12
15
18
22
28
35
42

6
8
10
12
15
18
22
28
35
42

0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.8

113
98
78
64
50
50
41
32
30
28

54
66.7
76.1
108
133
159

54
66.7
76.3
108
133
159.5

0.9
1.0
1.2
1.2
1.5
1.5

*Based on material in hard drawn condition at 65C

25
20
19
17
16
15
1 bar = 0.1N/mm = 10 5 N/m

Usage: Abov e groundserv ices including drinking w ater supply, hot and cold w ater systems,
sanitation, central heating and other general purpose applications.

LOW COST
UTILITY
RANGE

MECHANICAL PROPERTIES OF TUBE TO EN 1057


Temper

Nom. Dia.
(Outside)

MPa*

Minimum
Elongation

Hardness**

R220 Annealed
R250 Half Hard
R250 Half Hard
R290 Hard

6 to 54mm
6 to 66.7mm
6 to 159mm
6 to 267mm

220
250
250
290

40%
30% #
20% #
3%

40 to 70