Developing Energy Efficient Building Envelope (Roof)

Abdulkader Bengali, HeadSales & Marketing, Indian Sub Continent


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Agenda
Why Insulation ??? Energy Conservation Building Code Insulation
Energy Conservation Building Code
Selection Criteria Insulation Material Comparison

Roof System
Wall System

Why Insulation ???


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Where Energy goes from a house


Energy Costs are going through the roof, walls and windows

Energy Demand Roof & Wall

Need for High Efficient, Insulated Building Envelope

The Most Cost-effective Method for Decreasing Greenhouse Gas Emissions

Building Insulation

Curbing Global Energy Demand Growth: The Energy Productivity Opportunity Diana Farrell, McKinsey Global Institute May 2007

Energy Conservation Building Code (ECBC)


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Energy Conservation Building Code


Prescriptive Method

Trade Off Method


Whole Building Performance Method
Envelope Performance Factor (EPF)

Insulation Selection Criteria & Comparison


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

U Value
Amount heat transmitted in
unit time
through unit area of a material or construction and the boundary air films,

induced by unit temperature difference between the environments on each side.


Units of U are W/m2-C (Btu/h-ft2-F)

U = k/t
thickness)

(k = thermal conductivity of material & t = Area = 1 m2

T1 = 1 oC

U = 13 W/sqm K
(6 RCC Slab)

T2 = 0 oC

R Value Thermal resistance


The reciprocal of the time rate of heat flow
through a unit area
induced by a unit temperature difference between two defined surfaces of material or construction

Units of R are m2-C/W (h-ft2-F/Btu).

R = 1/U = t/k
(k = thermal conductivity of material & t = thickness)

Selection Criteria Insulation System for Concrete Building Envelope


Thermal Performance

Selection Thermal Resistance (R-Value) not on density & thickness


Eliminates or minimizes thermal bridging Ideal Location

Durable (weather-ability)

Functional
Absorbs minimum moisture

Should not be exposed to fire risks


Safe & Durable (aging and functional use)

Cell Structure Insulation Material


Foamular Metric eXtruded PolyStyrene (XPS) PolyUrethane Foam (PUF)

Expanded PolyStyrene (EPS)

Product ComparisonMoisture Absorption


Insulation should absorb minimum moisture for best thermal performance
Very low water absorption per ASTM C578 standard Property
Water Absorption, Vol. %
< 0.3c 2.0 - 4.0c 2.0 - 5.0e 115 - 287 5.0d 2.5 - 3.0e 144 - 176

XPSa

EPSa

SPUb

Water Vapor Permeance


perm ng/Pa.s.m2 1.1e 63

Thermal Resistance
F.ft2.h/btu Km2/W 5.0 0.88 3.1 - 4.2 0.55 - 0.74 6.2 1.10

XPS Extruded Polystyrene ; EPS Expanded Polystyrene ; SPU Sprayed Polyurethane

Notes : a. Data from ASTM C-578 ; b. Data from ASTM C-1029; c. Tested 24 hr ; d. Tested 96 hr ; e. Desiccant Method

Product Comparison R Value retention CRREL : 80% Minimum Acceptable


Moisture content affects thermal resistance
Select an insulation product ( for building envelope ) which retains its thermal resistance R Value

Retain R Value v/s Exposure to time @ 70% RH

XPS New Wetting Curves for Common Roof Insulations, U.S. Army Corps of Engineers Cold Regions Research and Engineering Laboratory (CRREL) April 1991

Prescriptive Method - Roof


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Roof Assembly: Insulation Requirements


As per Energy

Conservation Building Code (ECBC) 2007

Insulation Material Comparison

98 XPS = 116PUF = 175EPS = 420Bead Mortar=770 AAC = 2345 Clay Brick

R= 3.5 (m2 K/W) = 19.9 (F ft2 h/Btu)


XPS = Extruded Polystyrene; PUF = Polyurethane Foam; EPS = Expanded Polystyrene; AAC = Aerated Autoclave Concrete

Roof Insulation - System


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Roof Assembly: Insulation Requirements


As per Energy

Conservation Building Code (ECBC) 2007

Roof System U Values


Chemical Waterproofing Layer

75

150

Cement Screed

Chemical Waterproofing Layer

Brick Batt Coba

25

200

200

RCC Slab

RCC Slab

U Value : 3.19 W/m2.K

U Value : 2.61 W/m2.K

U Value for 24 hour use : 0.261 W/m2.K


As per ECBC

U Value for daytime use : 0.409 W/m2.K


Tile Screed Extruded Polystyrene Insulation

Geo Textile
Water Proofing Layer

Screed

U Value: 0.237 W/m2.K


RCC Slab

A layer of Insulation reduces U value by >10 times

75

Roof System
Screed Pavers Pebbles / Gravels Tile

Protective Membrane (Geo Textile)

Extruded Polystyrene Insulation Material Screed Mortar

Water Proofing Layer

Concrete Slab

PRMA System Types

Long Lasting Durability Dallas Forth Worth International Airport


Project Highlights PRMA System

3,036 squares re-roofed


88% of existing insulation reused $180,000 saved in new material cost $15,000 saved in hauling/landfill $100,000 saved in labor costs

Environmental Benefits Usable insulation recycled New product resource consumption minimized

Saving in Fossil fuels


Recycled insulation continues to save energy

Prescriptive Method - Wall


THE PINK PANTHER & 1964 2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2009 Owens Corning.

Wall Assembly: Insulation Requirements


As per Energy

Conservation Building Code (ECBC) 2007

U VALUE COMPARISON WALL SYSTEM


Single (Brick) Wall
Single (Brick) Wall + ACP ACP Double Wall (Brick) with air gap

9 thick cement plaster

air gap

U value: ~1.78

U value: ~1.40

U value: ~0.93

insulation on external fascade

U value: ~0.39 Single (Brick) Wall + 50mm Insulation

U value: ~0.40 Brick Wall + ACP + 50mm Insulation

U value: ~0.37 Double Wall + air gap + 50mm insulation


Source: Owens Corning

Unit in W/m2.K

Wall Solutions - External Insulation (Wet Cladding Paint )

Wall Solutions - External Insulation (Wet Cladding Tile )

Hangzhou Palm Bay

Wall Solutions - External Insulation (Dry Cladding ACP / Stone)


Metal Finish

Beijing Orient Plaza

Stone Finish

Wall Solutions - Internal Insulation (Dry & Wet)