Académique Documents
Professionnel Documents
Culture Documents
Compact C Range
Sludge pumping
Typical applications include: Domestic and industrial efuents Hydrated lime slurry Sludge Shear sensitive latex emulsion Milk curds, sauces, fruit juices Industrial chemicals and detergents Starch slurries Coating clays, gypsum and silicate Paper stocks Agricultural slurries
A competitively priced progressing cavity pump, with a compact construction and maximum performance characteristics.
Materials of construction Available in cast iron or stainless steel, with a choice of rotor and stator materials to suit individual applications e.g. hard chrome plated rotor or natural rubber stator.
High pressure / long haul pumping Can offer considerable project cost savings by utilizing small bore pipework and eliminating the need for a series of pumps, when pumping over long distances or with high head requirements.
Low running speeds Reduced wear for a longer working pump life which extends the periods between routine maintenance. Think of the savings that could be realized on abrasive applications.
To minimize the impact on the environment, this has been printed on recycled paper
Compact unit As the drive forms an integral part of the unit, the pump is ideal for space-saving installations.
Gentle pumping action Minimizes shear and crush damage to the pumped product.
Surface mounted Making it easier, cleaner and less hazardous for maintenance.
Up to 28ft suction lift Deep sumps can be easily pumped without the use of submersible equipment.
Plug in shaft Ease of maintenance when assembling or dismantling, with extraction facility.
Viscous products and heavy solids The pump can be supplied with a square inlet and auger to convey viscous slurries and heavy solids into the pumping element. Shaft sealing options Packed gland or single and double mechanical seals are available.
Sealed joints Fully sealed drive train to maximize life and minimize downtime.
Versatile Can be installed vertically or horizontally to suit the application. Can be run in either direction.
Robust drives Specially selected drives and gearboxes for longer life. Options include electric motor drive units supplied as overhead v-belt driven, direct-coupled or variable speed drives with mechanical variable speed or frequency inverter.
Duracoat coating Rotors can be supplied with Monoos range of specialized coatings to help extend the life of the rotors through improved wear and corrosion resistance.
Handles gas entrainment No air or gas locking in the pump. The positive seal formed by the interference t between rotor and stator enables the pump to self prime and it also allows tri-phase liquids i.e. solids, gases and liquids to be handled easily.
Product Dimensions
MODEL C21B C21D C22A C22B C22D C23A C23B C23K A 17 23 17 23 38 21 26 26 A1 5 10 5 10 21 7 12 12 B 12 17 12 17 32 15 21 21 C 5 5 5 5 5 5 5 5 D 11/4 11/4 11/4 11/4 11/2 1/
1 2
E 6 6 6 6 6 6 6 6
F 3 3 3 3 3 3 3 3
G 5 5 5 5 5 5 5 5
H 6 6 6 6 6 6 6 6
A1
DISMANTLING DISTANCE
A B D C
E G H
MODEL C17B C17D C18A C18B C18D C19A C19B C1AA C1AB C1BA A 58 103 49 69 110 55 73 58 85 71 A1 32 55 19 35 61 21 39 24 43 25 B 47 88 38 54 94 43 61 46 69 54 C 11 16 11 15 16 12 12 12 16 17 D 6 8 6 6 8 8 8 8 8 10 E 12 16 12 13 16 14 14 14 16 18 F 6 9 6 6 9 6 6 6 9 9 G 7 11 7 8 11 8 8 8 11 11 H 12 14 12 12 14 12 12 12 14 14
11/2 11/2
MODEL C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK C13D C2XA C2XB C1XD C14A C14B C14D C15A C15B C15D C16A C16B C16D C17A
A 30 39 43 50 58 65 73 79 96 46 22 30 54 31 39 58 33 46 70 38 53 86 44
A1 12 18 22 27 32 35 39 43 48 21 5 12 26 10 18 31 12 22 40 14 27 48 17
B 23 30 35 41 47 54 61 67 79 37 16 23 43 22 30 47 26 35 57 29 51 71 33
C 6 9 9 9 11 11 12 12 17 9 6 6 11 9 9 11 9 11 13 9 13 15 11
D 2 3 3 4 6 6 8 8 10 3 2 2 3 3 3 3 3 3 4 4 4 6 6
E 8 9 9 10 12 12 14 14 18 9 8 9 10 9 9 10 9 10 11 10 11 13 12
F 3 4 4 5 6 6 6 6 9 4 3 4 5 4 4 5 4 5 6 5 6 6 6
G 5 6 6 6 7 7 8 8 11 6 5 5 6 6 6 6 6 6 7 6 7 8 7
H 6 8 8 10 12 12 12 12 14 8 6 6 10 8 8 10 8 10 10 12 12 12 12
A1
DISMANTLING DISTANCE
A B D C
E G H F
MODEL S14A S14K S15A S15K S16A S16K S17A S17K S18A S18K
A 31 39 33 43 38 50 44 58 49 65
A1 10 18 12 22 14 27 17 32 19 35
B 21 29 23 33 27 39 31 45 36 52
C 9 9 9 9 11 11 13 13 13 13
D 7x7 7x7 7x7 7x7 8x8 8x8 9x9 9x9 9x9 9x9
E 9 9 9 9 10 10 12 12 12 12
F 4 4 4 4 5 5 6 6 6 6
G 6 6 6 6 6 6 7 7 7 7
H 8 8 8 8 10 10 12 12 12 12
A1
DISMANTLING DISTANCE
A B D C
E G H F
All dimensions in inches and for guidance only. Flanges to ANSI B16.1, B16.5 and NPT pipe thread. Dimension A1 is the preferred dismantling space. For full certied drawings, please contact Monoo.
Performance Data
K BUILD 991 C1BK 727 C1AK 550 C19K 427
CAPACITY GPM
616 414
TWO STAGE C1BB C1AB C19B C18B C17B C16B C15B C14B C2XB C23B C22B
FOUR STAGE
218 156
113 C15A / S15A 64 47 10.7 C2XA 26 C23A 15 C22A 7 C21B 0 87 175 C21D 350 C22D C13D C14A / S14A
Motor/Baseplate Dimensions
MODEL C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK C13D C2XA C2XB C1XD C14A C14B C14D C15A C15B C15D C16A C16B C16D C17A C17B C17D C18A C18B C18D C19A C19B C1AA C1AB C1BA LENGTH 51 66 70 77 97 104 114 120 137 72 44 52 80 57 66 84 60 72 109 64 92 127 81 97 145 87 110 151 96 114 99 126 112 WIDTH 12 12 14 14 14 17 17 17 21 14 12 12 17 12 12 14 12 14 17 14 17 21 14 14 21 14 17 21 17 17 17 21 21 HEIGHT 12 19 19 19 24 24 26 26 21 19 12 12 19 19 19 19 19 19 24 19 24 19 23 24 29 23 26 21 26 26 26 29 29 MODEL S14A S14K S15A S15K S16A S16K S17A S17K S18A S18K LENGTH 57 66 60 70 65 77 81 97 87 104 WIDTH 12 12 12 14 14 14 14 14 14 17 HEIGHT 19 19 19 19 19 19 23 24 23 24 MODEL C21B C21D C22A C22B C22D C23A C23B C23K LENGTH 39 45 39 45 61 43 49 49 WIDTH 12 12 12 12 12 12 12 12 HEIGHT 12 12 12 12 12 12 12 12
Length
Width
All dimensions in inches and refer to the largest selected drive. Dimensions are for guidance only, for full certied drawings, please contact Monoo.
Europe Mono Pumps Ltd, Martin Street Audenshaw, Manchester M34 5JA, England T. +44 (0)161 339 9000 E. info@mono-pumps.com D.M.I EST, 56 rue du Pont 88300 Rebeuville, France T. +33 (0)3 29 94 26 88 E. dmi-est@dmi-est.fr
Americas Monoo Inc., 10529 Fisher Road Houston, Texas 77041, USA T. +1 713 980 8400 E. inquire@monoo.com Monoo S.A., Ing Huergo 2239 (1842) Monte Grande Pcia. de Buenos Aires, Argentina T. +54 11 4290 9940/50 E. info@monoo.com.ar
Australasia Mono Pumps (Australia) Pty Ltd 338-348 Lower Dandenong Road Mordialloc, Victoria 3195 Australia T. 1800 333 138 E. ozsales@mono-pumps.com Mono Pumps (New Zealand) Ltd PO Box 71-021, Fremlin Place Avondale, Auckland 7 New Zealand T. +64 (0)9 829 0333 E. info@mono-pumps.co.nz
Asia Mono Pumps Ltd No. 500 YaGang Road Lujia Village, Malu Jiading District Shanghai 201801, P.R. China T. +86 (0)21 5915 7168 E. monoshanghai@nov.com
www.monoo.com
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoos standard terms and conditions of sale, available on request. Monoo products are marketed outside North America under the mark Mono. Literature reference: MFI-C/R1 2008 Monoo is a registered trademark of Mono Pumps Ltd.
Produced on recycled paper
Height
Compact C Range
Typical Applications Domestic and industrial effluent Hydrated lime slurry Sludge Shear sensitive latex emulsion Milk curds, sauces, fruit juices Industrial chemicals and detergents Starch slurries Coating clays, gypsum and silicate Paper stocks Agricultural slurries
A competitively priced progressing cavity pump, with a compact construction and maximum performance characteristics.
Capacity Pressure
Compact unit Materials of construction High pressure / long haul pumping Low running speeds Duracoat coating Viscous products and Heavy Solids Gentle pumping action Up to 28ft suction lift Inspection cover Robust drives
As the drive forms an integral part of the unit, the pump is ideal for space-saving installations. Available in cast iron or stainless steel, with a choice of rotor and stator materials to suit individual applications e.g. hard chrome plated rotor or natural rubber stator. Can offer considerable project cost savings by utilizing small bore pipework and eliminating the need for a series of pumps, when pumping over long distances or with high head requirements. Reduced wear for a longer working pump life which extends the periods between routine maintenance. Think of the savings that could be realized on abrasive applications. Rotors can be supplied with Monoflos range of specialized coatings to help extend the life of the rotors through improved wear and corrosion resistance. The pump can be supplied with a square inlet and auger to convey viscous slurries and heavy solids into the pumping element. Minimizes shear and crush damage to the pumped product. Deep sumps can be easily pumped without the use of submersible equipment. Available for applications where rag content is a problem. Specially selected drives and gearboxes for longer life. Options include electric motor drive units supplied as overhead v-belt driven, direct-coupled or variable speed drives with mechanical variable speed or frequency inverter.
Performance Data
K BUILD 991 727 C1AK 550 C19K 427
CAPACITY GPM
616 414
TWO STAGE C1BB C1AB C19B C18B C17B C16B C15B C14B C2XB C23B C22B
FOUR STAGE
C1BK
C18K / S18K C17K / S17K C16K / S16K C15K / S15K C14K / S14K C1XK
44
C23K 0 58 87
Dimensions
MODEL LENGTH WIDTH HEIGHT C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK C13D C2XA C2XB C1XD C14A C14B C14D C15A C15B C15D C16A C16B C16D C17A C17B C17D C18A C18B C18D C19A C19B C1AA C1AB C1BA 51 66 70 77 97 104 114 120 137 72 44 52 80 57 66 84 60 72 109 64 92 127 81 97 145 87 110 151 96 114 99 126 112 12 12 14 14 14 17 17 17 21 14 12 12 17 12 12 14 12 14 17 14 17 21 14 14 21 14 17 21 17 17 17 21 21 12 19 19 19 24 24 26 26 21 19 12 12 19 19 19 19 19 19 24 19 24 19 23 24 29 23 26 21 26 26 26 29 29 F 2 3 3 4 6 6 8 8 10 3 2 2 3 3 3 3 3 3 4 4 4 6 6 6 8 6 6 8 8 8 8 8 10 G 2 3 3 4 6 6 8 8 10 2 2 2 3 3 3 3 3 3 4 4 4 6 6 6 6 6 6 8 8 8 8 8 10 MODEL S14A S14K S15A S15K S16A S16K S17A S17K S18A S18K MODEL C21B C21D C22A C22B C22D C23A C23B C23K LENGTH WIDTH HEIGHT 39 45 39 45 61 43 49 49 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 F&G 11/4 11/4 1 /4
1
Length
Width
All dimensions in inches and for guidance only. Flanges to ANSI B16.1, B16.5 and NPT pipe thread.
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-C/R1 Flyer Monoflo is a registered trademark of Mono Pumps Ltd.
Height
1 1 NOV 2006
SELECTION PROCEDURE
PUMP SIZING 1 From the pre-selection table (page 5) select the pump model which initially meets the required capacity / pressure criteria. (Refer to NOTES on page 4) 2 Referring to the performance data in sections 2 & 3 if particle size is a factor then refer to the table labelled SOLIDS HANDLING (inches) on the performance graph to verify the pumps suitability. 3 If variable speed is required then select at maximum capacity. 4 On the y-axis (Capacity) identify the required flow then move horizontally until intersection at the required differential pressure.(see 5). 5 Slip Correction for Viscosity a) If Viscosity is equal to or greater than six (6) stokes then select on the zero PSI pressure line to determine the pump speed required for the duty. From the point of intersection on the curve move vertically down to the x-axis labelled Speed to obtain the required RPM. b) If the viscosity is less than six (6) stokes then the following procedure applies:Use the method given here as Figs. 1 and 2 to estimate Slip and calculate the required pump speed. Slip Correction for Viscosity n = np - [ (np - no) f ] or n = np - f.ns where n = corrected duty speed no = rpm at zero PSI for duty flow rate (from water performance curves) np = rpm at duty pressure for duty flow rate (from water performance curves (Fig 1)) np-no = Slip speed = ns From viscous slip curve (Fig 2) read slip factor f f x ns = slip speed correction = f.ns Corrected Speed for Duty n = np - f.ns
SLIP FACTOR (f)
Example
176
PERFORMANCE CURVES BASED ON WATER AT 68F
132
CAPACITY (gpm)
0 PSI 58 PSI
88
44 no np
100
200
300
400
500
SPEED RPM
Fig 1 Duty 88gpm, 58 PSI 100 centistokes (viscosity in pump) Corrected Duty Speed n = np - [ (np - no) f ] n = 410 - [ (410-300) x .78 ] = 324 rpm or n = np - f.ns n = 410 - 85.5 = 324 rpm
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Fig 2 Note: There is no slip correction necessary for water or product with a viscosity of one (1) centistoke.
Published information other than that marked certified is to be used as a guide only
1 2 NOV 2006
SELECTION PROCEDURE
6 When RPM is established identify: a) Maximum viscosity as indicated at the top of the performance curve labelled Viscosity Limits. Refer to page 3, Tolerance guidelines - Viscosity Limits. b) Abrasion capability as indicated at the top of the performance curve labelled Abrasion zone. Refer to page 3, Tolerance guidelines - Abrasion zone. If any of the parameters in steps 1 to 6 (b) do not meet the required criteria then re-select from (1) above with the next largest pump size. c) Rotor selection against temperature as indicated in the shaded area of the performance curve for the duty speed identified. Refer to Tolerance guidelines - Rotor selection. d) Absorbed power which is read on the y-axis (Absorbed power) at the differential pressure intersection point (BHP). If the product is viscous then note also the absorbed power on the zero pressure line (FHP) for use later in calculation. 7 If the pump meets the above criteria go to the PUMP CONFIRMATION SECTION. If no pump can be identified then please contact Monoflo for assistance. PUMP CONFIRMATION Having determined the pump size the following steps are necessary: 1 Read the NPSH required from the pump curve at the duty flowrate. Check that the N.P.S.H. required is less than N.P.S.H. available. 2 Note the starting torque required on the performance curve in the table labelled STARTING TORQUE against the selected rotor. 3 If the product is viscous obtain both Starting Torque (f T) and Power Additive (f FHP) factors from the Viscosity Curve graph read at the known viscosity in Stokes. 4 Confirm stator suitability for the product. (Refer to page 3, Tolerance guidelines - Stator selection) 5 Confirm material compatibility and availability for the pump chosen. 6 Select mechanical seal (standard) or packed gland as required. DRIVE Information obtained from the PUMP CONFIRMATION section will be used to determine the required drive. 1 If product is water like, then the absorbed power (BHP) will be as obtained in the PUMP SIZING section, step 6, item (d). Go to step 4. 2 Multiplying the pump starting torque by the starting torque factor obtained in the PUMP CONFIRMATION section, item 3 will give you the starting torque required for the given viscosity. (ie T(ft-lb) x fT = Starting torque at viscosity).(Refer to section DRIVE, items 5 and 6) 3 To obtain the power absorbed at the known viscosity then the full viscous calculation is: Viscous Brake Horsepower (V BHP) = Viscous frictional H.P. + W.H.P. a) Viscous Frictional Horsepower FHP x f FHP. FHP as identified in Pump Sizing section step 6, item (d) (zero PSI pressure). f FHP factor as identified in Pump Confirmation section step 3. Multiply FHP by correction factor f FHP to give frictional horsepower when handling the viscous product. b) Water Horsepower (WHP) is BHP - FHP BHP as identified in Pump Sizing section step 6, item (d) (at duty pressure). FHP as identified in Pump Sizing section step 6, item (d) (at zero PSI pressure). WHP is BHP - FHP c) Add viscous frictional horsepower to water horsepower to obtain BHP absorbed when handling a viscous product i.e. a + b.
4 Determine the motor input power required by allowing for the efficiency of the drive arrangement as follows: Efficiency % Drive Arrangement D.C. to a synchronous speed motor 100 D.C. to a fixed speed geared motor 92 D.C. to a variable speed geared motor 80 (D.C. = Direct Coupled) Therefore input power = BHP (or vBHP) divided by the efficiency.(ie. Input power required for a close coupled CB pump with a direct coupled fixed speed geared motor = BHP (or vBHP) / 0.92)
1 3 OCT 2007
SELECTION PROCEDURE
5 Starting torque capabilities will be affected by the type of drive selected and method of starting. Generally motors wired for D.O.L. start on a 3 phase supply will provide 200% FLT (Full Load Torque). Motors wired for Star/Delta start on a 3 phase supply typically provide 50-70% FLT. Single phase motors (capacitor start) typically provide 200% FLT. In all cases reference should be made to the motor manufacturers performance tables. D.O.L. is the preferred method of starting a PC pump. 6 If starting is via an inverter type of drive then 125% FLT availability only is assumed. The correct matching of drive motor/inverter/pump is a specialised skill. Breakout torque and continuous slow running can cause problems. Always refer an inverter application to a specialist drive company, ensuring that they are aware of the full duty parameters to enable them to select the appropriate drive package. 7 Starting with a soft starter should be referred to the manufacturers specification, but typically starting torque will be 150% FLT. 8 Care should be taken when selecting other types of drives to ensure sufficient starting torque is available, i.e. single phase, hydraulic drives, air motors, engines etc. If in doubt refer to Monoflo. TOLERANCE GUIDELINES Rotor Selection Consider maximum fluid temperature, ambient temperature, operating speed and duration of running. All these factors affect stator temperature, in borderline cases select the higher temperature rotor. Fixed Speed If selection falls exactly between rotor types then select the higher temperature rotor. Variable Speed For variable speed drives select the rotor at maximum speed and maximum temperature. Mark 0 Rotors Mark 0 rotors are designed for use with water like liquids, i.e. less than 200 centistokes, or abrasive liquids. Use where either of the following details apply i) ii) iii) Pressure per stage is greater than twenty nine (29) PSI or Suction required is greater then ten (10) feet H 20 or Medium/heavy abrasion type liquids.
Mark 0 rotors must not be selected for use in conjunction with RH, RV & RJ stators. Please consult Monoflo. Stator Selection Performance curves based on RR and RA stator materials. RR, RA, RH and RV are Mono stator material codes and are contained in the stator selection for each model. Please note that the following must be adhered to when selecting the stator grades: (RH) Refer to page 8 to identify starting torque and temperature rotor requirements. (RV) Refer to page 9 for limitations on speed & pressure The power absorbed must be increased by a factor of 1.2 Applications above 50oC (88oF) should be refered back to Mono Pumps Ltd.
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
1 4 NOV 2006
STATUS
SELECTION PROCEDURE
NOTES Flow Rate The expected accuracy of progressing cavity pumps is 10% of pump maximum flowrate as shown by the Product Manual Curves. If specific duty points must be achieved ensure that Monoflo are aware of this. Viscosity limits The viscosity limits are shown in logarithmic scale and indicate maximum recommended viscosities in the pump for the speed selected. Abrasion zone The abrasion zone provides a guide to the pumps ability to handle abrasive products at different speeds with acceptable component life. Pressure has a proportional effect on wear therefore increasing the number of stages at constant pressure will significantly improve component life. PUMP ROTATION (DOG/SOG) The pump rotation is normally assumed anticlockwise (when looking on the pump drive shaft end) such that SOG (Suction-On-Gland) flow conditions prevail (ie, product enters at the suction chamber and leaves at the discharge chamber). PRESSURE LIMITATIONS The construction of each different range of pumps will result in maximum discharge pressures and maximum differential pressures that may differ depending upon the specific model, direction of rotation and port fittings. It is therefore important to check that both the differential pressure plus the inlet pressure do not exceed the maximum discharge pressure for the pump selected. Please refer to section 5-13 pages 1 & 2. TEMPERATURE LIMITATIONS Temperature limitations are dependant on material combinations used. If duty temperatures are outside the limits shown for a particular combination please contact Monoflo for guidance. Compact Range The normal maximum running temperature is 212F. SPEED LIMITATIONS If speeds below 50rpm are required then please contact Monoflo for assistance.
Published information other than that marked certified is to be used as a guide only
COMPACT
1 5
ALL CURRENT
SEPT 2008
SINGLE STAGE
TWO STAGE
FOUR STAGE
C1DA C1CA C1CB C1BB C1AB C19B C18B C17B C16B C15B C14B C2XB C23B C22B C21B C18D C17D C16D C15D C14D C1XD C13D C22D C21D
175 350
C1CK C1BK
726 550
CAPACITY GPM
616
C1BA
413
C1AA
314
C1AK C19K
CAPACITY GPM
C19A
253 217 156 112
C18K / S18K C17K / S17K C16K / S16K C15K / S15K C14K / S14K C1XK C23K
0 58 87
63 49
26 15
C23A C22A
87
Published information other than that marked certified is to be used as a guide only
1 6
SEPT 2008
Range Design Mk No
Monobloc Compact Monobloc Compact Square Inlet Monobloc Monobloc (January 2007) 5.7 gpm @ 1750 rpm 14.5 gpm @ 1750 rpm 44.0 gpm @ 1500 rpm 57.2 gpm @ 1500 rpm 96.8 gpm @ 1000 rpm 162.9 gpm @ 800 rpm 250.9 gpm @ 700 rpm 347.8 gpm @ 600 rpm 427.0 gpm @ 500 rpm 550.5 gpm @ 450 rpm 726.4 gpm @ 400rpm 990.6 gpm @ 350 rpm 1937.2 gpm @ 270 rpm 1276.8 gpm @ 270 rpm Single stage Two stage Four stage Single stage - extended pitch Cast Iron Stainless steel Code 1
C S 1 2
1 2 3 X 4 5 6 7 8 9 A B C D
Size
Stages
A B D K C S 1 5 8 0 1 3 5 R M P A B H / A 1 2 3
Casing Material
Rotating Parts 1
Rotor Mk No
Mk1 (Standard) Mk3 (Temperature) Mk5 (Temperature) RA, RR etc. Mechanical Seal Packed Gland Refer to product manual section 2 & 3, drive selections
C C Range
1 Design Mk 1
X Size 0X
A Single Stage
C Cast Iron
1 Mk 1 Rotor
R Nitrile Stator
1 7 NOV 2006
1000
Starting Torque
Power Additive
100
10
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
1 8 NOV 2006
MARK 5 ROTOR
When selecting pumps fitted with RH stators, please use the above rotor selection chart which indicates rotor type and recommended pump breakout torque multiplier for a given fluid temperature. The torque multiplier is required to allow for increased interference between rotor and stator. Notes 1. Mark zero rotors are not to be used with RH or RJ stators. 2. Rated speed is the maximum speed shown for each pump model as indicated on the appropriate performance curve. 3. If the pump is to be operating for less than 15 minutes per hour then select the next larger rotor size (i.e. if mark 5 rotor is initially selected then select mark 3).
COMPACT
1 9
ALL CURRENT
OCT 2007
SPEED / PRESSURE DERATE WHEN USING RV STATORS (UP TO 50oC) (880F) (Moulded to metal stators only)
100%
NOT SUITABLE
75%
Rated Speed
50%
25%
COMPACT
C21B
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 2 1
104 68 32
0.5
Limit for water like products Capacities below this line require verification by Monoflo. 0 0
PSI
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.14
0.40
5.9
5.2
5.2
5.2
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 1 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C21B SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C21D
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 2 1
1.5
MARK 5 MARK 3 PSI
0 174 261 348
MARK 1 MARK 0 4
104 68 32
0.5
Limit for water like products Capacities below this line require verification by Monoflo. 0
PSI
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.14
0.40
11.8
10.3
10.3
10.3
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 1 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C21D SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C22A
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
15
3.5
MARK 5 PSI
176
13
3.0
MARK 0
MARK 3 MARK 1
0 29 43 58 87
140 104 68 32
2.0
1.0
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 1.0
PSI 1.5
0.6 0.4
58 29
0.8 0.5
0.2 0
0 200 400 600 800 1000 Pump Speed (rpm) 1200 1400 1600 1800
0.3 0
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.14
0.40
7.4
5.9
5.9
5.9
Published information other than that marked certified is to be used as a guide only
0.8
87
1.1
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 2 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C22A SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C22B
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
15
3.5
MARK 5 PSI
0 58 87 116 174
13
3.0
MARK 0
MARK 3 MARK 1
2.0
1.0
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 1.6
2.0
174
116 87 58
PSI
1600
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.14
0.40
11.8
7.4
7.4
7.4
Published information other than that marked certified is to be used as a guide only
1.4
1.8
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 2 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C22B SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C22D
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
15
3.5
MARK 5 PSI
0 116 174 232 348
13
MARK 3
3.0
MARK 1 MARK 0
2.0
1.0
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 3.2
4.2
348
PSI
400
600
1200
1400
1600
1800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.14
0.40
23.6
20.6
20.6
20.6
Published information other than that marked certified is to be used as a guide only
2.8
3.7
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 2 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C22D SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C23A
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32
26
6
PSI MARK 5 MARK 3
0 29 58 87
22
5
MARK 1 MARK 0
17
13
1
Limit for water like products Capacities below this line require verification by Monoflo.
0 1.6
2.1
87 58 29 0
PSI
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.20
0.80
18.4
11.0
11.0
11.0
Published information other than that marked certified is to be used as a guide only
1.4
1.9
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 3 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved -10C (14F) 70C (158F) Yes Max 1500rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS NB mm (inch) ORIENTATION OPTION STANDARD SPECIFICATION OPTION
Can be rotated
1 B.S.P.
1 N.P.T.
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION Can be rotated STANDARD 1 B.S.P. OPTION 1 N.P.T.
COMMENTS
SEALING ARRANGEMENT PUMP SIZE C23A SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C23B
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32
26
22
5 MARK 1 MARK 0
17
13
1 Limit for water like products Capacities below this line require verification by Monoflo.
3.0
4.0
116 58
0.5 0
0 200 400 600 800 1000 Pump Speed (rpm) 1200
PSI
0.7 0
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.20
0.80
25.8
18.4
18.4
18.4
Published information other than that marked certified is to be used as a guide only
2.5
174
3.4
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 3 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS NB mm (inch) ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION Can be rotated STANDARD 1 B.S.P. OPTION 1 N.P.T.
COMMENTS
SEALING ARRANGEMENT PUMP SIZE C23B SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C2XA
CURRENT
MEDIUM 10
LIGHT 2
12
MARK 5 MARK 3 PSI 0 29 58 87
44
10
MARK 1
MARK 0 68 32
26
17
2
Limit for water like products Capacities below this line require verification by Monoflo.
0 3.0
PSI
4.0
87
58 29 0
0.5 0
0 200 Rotor Selection 400 600 800 1000 1200 1400 1600 1800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.24
0.94
17.7
13.3
13.3
13.3
Published information other than that marked certified is to be used as a guide only
2.5
3.4
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE X 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
31
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 50 (2) 50 (2) ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C2XA SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C2XB
CURRENT
MEDIUM 50 20 10
LIGHT 2
Viscosity Limits (Stokes)
NIL
Abrasion Zones
100
0.01
230 212
52
MARK 5 MARK 3 44
10
PSI
0 58 116 174
MARK 1 MARK 0
35
26
17
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 6
8.0
174 116 58 0
5 4 3 2 1 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.24
0.94
32.5
22.1
22.1
22.1
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE X 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
31
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 50 (2) 50 (2) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C2XB SHAFT DIAMETER 32mm (1.25) STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C13D
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32
26
6
PSI MARK 5 MARK 3
0 116 232 348
22
5
MARK 1 MARK 0
18
13
1
Limit for water like products Capacities below this line require verification by Monoflo.
0
6.0
8.0
348 232 116
1.0 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
20
70
50
50
50
Published information other than that marked certified is to be used as a guide only
5.0
6.7
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 3 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ RR RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C13D03
C13D CURRENT
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 65 (2.5) 65 (2.5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
OPTION ANSI B16.5 Class 300 125 RF JIS B2210 10 20 kgf ANSI B16.5 Class 300 150 RF JIS B2210 10 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C13D SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1XD
CURRENT
MEDIUM 50 20 10
LIGHT 2
Viscosity Limits (Stokes)
NIL
Abrasion Zones
100
0.01
230 212
53
PSI
0 116 232 348
MARK 3 44
10
MARK 1 MARK 0
35
8
32
26
18
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 12
12
348 232 116 0
10 8 6 4 2 0
10 8 6 4 2 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
24
88
60
60
60
Published information other than that marked certified is to be used as a guide only
Temperature (F)
MARK 5
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE X 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
31
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C1XD03
C1XD CURRENT
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 80 (3.1) 80 (3.1) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
OPTION ANSI B16.5 Class 300 RF 20 kgf JIS B2210 10 ANSI B16.5 Class 300 RF 20 kgf JIS B2210 10
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1XD SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL SingleDouble DIN 24960 OPTIONAL PACKED GLAND 6 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C14A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212
20
66.0
15
PSI
0 29 58
140 104
MARK 1 MARK 0
87
68 32
39.6
26.4
13.2
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 3
PSI
67 58
4.0
2.7
29
1
0
1.3
100
200
300
400
500
600
700
800
900
1000
0.24
0.87
36.88
22.1
22.1
22.1
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 4 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 65 (2.5) 65 (2.5) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C14A SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C14B
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212
20
66
15
MARK 5 MARK 3 PSI
0 87 116 145 174
140 104 68 32
52
12
MARK 0
MARK 1
39
26
13
3
Limit for water like products Capacities below this line require verification by Monoflo.
0 6
174
145 116 87 58
5.3
29 0
2.7
100
Rotor Selection
200
300
400
500
600
700
800
900
1000
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.24
0.87
66.4
36.8
36.8
36.8
Published information other than that marked certified is to be used as a guide only
PSI
8.0
Temperature (F)
176
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 4 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 65 (2.5) 65 (2.5) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C14B SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C14D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212 176
20
66
15
MARK 5 MARK 3 PSI
0 218
140 104 68 32
52
12
MARK 0
MARK 1
290 348
39
26
13
3
Limit for water like products Capacities below this line require verification by Monoflo.
0 12
PSI
16
12
174 116
72 0
100
200
300
400
600
700
800
900
1000
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
Above data represents tests on water @ 20C using RR and RA stator materials.
30
150
100
100
100
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 4 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C14D03
C14D CURRENT
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 80 (3) 80 (3) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
OPTION ANSI B16.5 Class 300 JIS B2210 10 20kgf ANSI B16.5 Class 300 JIS B2210 10 20kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C14D SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C15A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230
20
110
25
MARK 5 MARK 3 PSI
88
20
MARK 1
MARK 0
87 68 32
66
15
44
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo.
0 5
4 3 2 1 0
87
58 29 0
100
Rotor Selection
200
300
400
Pump Speed (rpm)
500
600
700
800
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
0.40
1.38
62.7
36.7
36.7
36.7
Published information other than that marked certified is to be used as a guide only
PSI
6.7
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 5 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 80 (3) 80 (3) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C15A SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C15B
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
20
(Stokes)
230 212
110
25
MARK 5 MARK 3 PSI
176
88
20
MARK 1
0 87 130 174
140 104 68 32
MARK 0 66
15
44
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo.
0 10
13.4 PSI
145
6 4 2 0
116 87 58 29 0
100
200
300
400
500
600
700
800
0.28
1.06
118.0
73.8
73.8
73.8
Published information other than that marked certified is to be used as a guide only
174
10.7
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 5 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL NB mm (inch) 80 (3) 80 (3) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
BODY MATERIAL
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C15B SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C15D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230 212 176 140 104 68
20
110
25
MARK 5 MARK 3
0
88
20
MARK 1
218 348
MARK 0
66
15
32
44
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo.
0 20
348
15
290 232
20.1
10
174 116
13.4
58 0
6.7
200
300
500
600
700
800
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
10
32
350
150
150
150
Published information other than that marked certified is to be used as a guide only
PSI
26.8
Temperature (F)
PSI
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 5 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C15D03
C15D CURRENT
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 100 (4) 100 (4) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
OPTION ANSI B16.5 Class 300 JIS B2210 10 20 kgf ANSI B16.5 Class 300 JIS B2210 10 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C15D SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C16A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230 212 176
20
40
MARK 5 MARK 3 MARK 1 PSI
0 29 58 87
154
35
140 104 68 32
132
30
MARK 0
110
25
88
20
66
15
44
10
22
Limit for water like products Capacities below this line require verification by Monoflo. 10.7
87 58
0 8
8.0
4
29
5.4
2
0
2.7
100
Rotor Selection
200
300
400
500
600
700
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.47
1.57
103.5
62.7
62.7
62.7
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 6 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 100 (4) 100 (4) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C16A SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C16B
CURRENT
LIGHT 2 0.01
230 212 176 140 PSI 104 0 131 68 32 174 Temperature (F)
176
40
MARK 5 MARK 3
154
35
MARK 1 MARK 0
132
30
110
25
88
20
66
15
44
10
22
Limit for water like products Capacities below this line require verification by Monoflo.
0 15
PSI
20.1
174
10
145 116 87
13.4
58 29 0
6.7
0
0 100
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.47
1.41
184.4
110.7
110.7
110.7
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 6 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 100 (4) 100 (4) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C16B SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C16D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230 212 176
20
40
MARK 5
154
35
MARK 1
MARK 3 PSI
0
140 104 68 32
132
30
MARK 0
218 348
110
25
88
20
66
15
44
10
22
Limit for water like products Capacities below this line require verification by Monoflo. 40.2
348
0 30
20
26.8
10
116 58 0
13.4
200
300
500
600
700
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
10
34
560
350
350
350
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 6 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C16D03
C16D CURRENT
SEPT 2006
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS NB BODY mm MATERIAL (inch) Cast Iron St. Steel 125 (5) 125 (5)
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.1 PN 40 BS EN 1092 Section 3.1 PN 40
SPECIFICATION
OPTION ANSI B16.5 Class 300 JIS B2210 10 20 kgf ANSI B16.5 Class 300 JIS B2210 10 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C16D SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C17A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2 0.01
230
50
MARK 5 PSI
0
45
MARK 3
29 58
40 35
MARK 1
87
MARK 0
68 32
132 110 88 66 44 22 0
30 25 20 15 10 5 0 12
Limit for water like products Capacities below this line require verification by Monoflo. 16.0 13.4 10.7
58
PSI
87
10 8 6 4 2 0
8.0
29
5.4 2.7 0
100
Rotor Selection
200
300
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.55
1.73
162.3
73.8
73.8
73.8
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 7 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C17A SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C17B
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2 0.01
230
50
MARK 5 PSI
0
45
MARK 3
87 145 174
40 35
MARK 1
MARK 0
132 110 88 66 44 22 0
30 25 20 15 10 5 0 20
Limit for water like products Capacities below this line require verification by Monoflo. 26.9
PSI
174 145 116
15
20.1
10
87 58
13.4
29 0
6.7
100
Rotor Selection
200
300
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.55
1.73
332.0
184.4
184.4
184.4
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 7 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A
1000
100
10
0.1
0.01
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C17B SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C17D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2 0.01
230 212 176 140 104 68
50
MARK 5 PSI
0
45
MARK 3
40 35
MARK 1
MARK 0
132 110 88 66 44 22 0
30 25 20 15 10 5 0
Limit for water like products Capacities below this line require verification by Monoflo.
32
40
348
30
290 232
40.2
20
174 116
26.8
10
58 0
13.4
200
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
14
42
750
500
500
500
Published information other than that marked certified is to be used as a guide only
PSI
53.6
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 7 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
COMPACT
2 C17D03
C17D CURRENT
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (5.9) 150 (5.9) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS NB BODY mm MATERIAL (inch) Cast Iron St. Steel 125 (5) 125 (5)
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.1 PN 40 BS EN 1092 Section 3.1 PN 40
SPECIFICATION
OPTION ANSI B16.5 Class 300 JIS B2210 10 20 kgf ANSI B16.5 Class 300 JIS B2210 10 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C17D SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C18A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2
230 212
50
Viscosity Limits (Stokes)
60
MARK 5 MARK 3 PSI
220
50
MARK 1 MARK 0
132
176
40
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
0 12
16.1
87
10 8
13.4 10.7
58
6 4 2 0
29
100
Rotor Selection
200
300
Pump Speed (rpm)
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
Above data represents tests on water @ 68F using RR and RA stator materials.
0.63
2.09
184.4
132.8
132.8
132.8
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 8 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0 0 0 30 20 40 50 10 Pump Capacity (m/h) 88 132 176 220 44 Pump Capacity (gpm) 60 264
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section ? No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section ? No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH
Chlorosulphonated PE
RV Fluoroelastomer Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 125 (5) 125 (5) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C18A SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C18B
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2
230 212
500
100
50
Viscosity Limits (Stokes)
PSI
176 0 87 145 140 104 68 32
MARK 1 MARK 0
174
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo. 0
0 24
32
174 145 116 87
20 16 12 8 4 0
26 21 16 10 5 0
58 29 0
100
Rotor Selection
200
300
Pump Speed (rpm)
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = n p - no, f x ns = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
Above data represents tests on water @ 68F using RR and RA stator materials.
12
43
368.8
276.6
276.6
276.6
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 8 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0 0 0 30 20 40 50 10 Pump Capacity (m/h) 88 132 176 220 44 Pump Capacity (gpm) 60 264
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No -5C (23F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black RV Fluoroelastomer Black RW Nitrile Rubber White High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C18B SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C18D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2
230 212 176
0 174 261
50
Viscosity Limits (Stokes)
60
MARK 5 MARK 3 PSI
220
50
MARK 1 MARK 0
140 104 68 32
348
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
0 50
67.0 53.6
348 290 232
40 30 20 10 0
174 116 58 0
300
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
Above data represents tests on water @ 20C using RR and RA stator materials.
13
44
1000
600
600
600
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 8 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0 0 0 30 20 40 50 10 Pump Capacity (m/h) 88 132 176 220 44 Pump Capacity (gpm) 60 264
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 100C (212F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black *RY/RK Urethane Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines. *Consult Monoflo for specific applications.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (2.56) 150 (2.56) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS NB BODY mm MATERIAL (inch) Cast Iron St. Steel 150 (2.56) 150 (2.56)
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.1 PN 40 BS EN 1092 Section 3.1 PN 40 SPECIFICATION OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C18D SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single/Double DIN 24960 OPTIONAL PACKED GLAND 6 r i n g s , 1 5 s q u a re
Published information other than that marked certified is to be used as a guide only
COMPACT
C19A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2
230 212 176
50
MARK 5 308
70
140 104 68 32
264
60
220
50
87
176
40
132
30
88
20
44
10
0 15
Limit for water like products Capacities below this line require verification by Monoflo. 20.1
87
10
58
13.4
29 0
6.7
100
Rotor Selection
200
Pump Speed (rpm)
300
400
450
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
Above data represents tests on water @ 68F using RR and RA stator materials.
0.71
2.20
202.9
147.5
147.5
147.5
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
352
80
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1000
0.1
0 0 44 88 132 176 220 264 308 352 Pump Capacity (m/h) 88 132 176 220 264 308 352 Pump Capacity (gpm)
44
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RJ RR Nitrile Rubber Black High Nitrile Chlorosulphonated PE Rubber Black Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (6) 150 (6) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C19A SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C19B
CURRENT
HEAVY
Abrasion Zones
MEDIUM 100
Viscosity Limits (Stokes)
LIGHT 20 10 2
230 212
1000
500
50
352
80
MARK 5 MARK 3 MARK 1 MARK 0 PSI
0 87 130
308
70
264
60
174
220
50
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo. 37.5
174
0 28 24 20 16 12 8 4 0
43 0 87
PSI
100
200
300
400
450
0.71
2.20
405.7
368.8
368.8
368.8
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1000
0.1
0 0 44 88 132 176 220 264 308 352 Pump Capacity (m/h) 88 132 176 220 264 308 352 Pump Capacity (gpm)
44
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (6) 150 (6) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C19B SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1AA
CURRENT
MEDIUM
Abrasion Zones
LIGHT 50 20 10 2
230
90
MARK 3
80 70
MARK 1
58 87 104 68 32
MARK 0
60 50 40 30 20 10 0 20
26.8
87
Limit for water like products Capacities below this line require verification by Monoflo.
15
58
20.1
10
29
13.4
5
0
6.7
50
Rotor Selection
100
150
200
250
300
350
400
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.80
2.76
295.0
258.1
258.1
258.1
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
440
100
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE A 4
1000
0.1
0 0 60 40 80 20 Pump Capacity (m/h) 264 176 352 88 Pump Capacity (gpm) 100
440
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes see Section 1 No RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black RV Fluoroelastomer Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 150 (6) 150 (6) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1AA SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1AB
CURRENT
MEDIUM
Abrasion Zones
LIGHT 50 20 10 2
230 212
90
MARK 3
PSI
0 130 174 176 140 104
80 70
MARK 1
MARK 0
68 32
60 50 40 30 20 10 0 40
53.6
174
Limit for water like products Capacities below this line require verification by Monoflo.
30
40.2
145 116
20
87 58
26.8
10
29 0
13.4
50
Rotor Selection
100
150
200
Pump Speed (rpm)
250
300
350
400
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3
0.80
2.56
626.9
479.4
479.4
479.4
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
440
100
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE A 4
1000
0.1
0 0 60 20 40 80 Pump Capacity (m/h) 264 176 352 88 Pump Capacity (gpm) 100
440
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RJ High Nitrile Rubber Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL NB mm (inch) 150 (6) 150 (6) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Cast Iron
Vertical
Can be rotated
St. Steel
Vertical
Can be rotated
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1AB SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1BA
CURRENT
MEDIUM
Abrasion Zones
LIGHT 50 20 10 5
MARK 5
PSI
0 43 72 87
100 90 80 70 60 50 40 30 20 10 0 30
Limit for water like products Capacities below this line require verification by Monoflo. 40.2
87
20
58
26.8
29
10
0
13.4
50
Rotor Selection
100
150
200
250
300
350
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.98
3.86
516.3
442.5
442.5
442.5
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
660
150
230 212
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE B 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0 0 0 50 750 100 125 150 25 Pump Capacity (m/h) 110 220 330 440 550 660 Pump Capacity (gpm)
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes see Section 1 No -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RH RR
Black
Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel NB mm (inch) 200 (8) 200 (8) ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1BA SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1BB
CURRENT
HEAVY 1000
500
100
Viscosity Limits (Stokes)
50
20
10
5
230 212 176 140 104 68 32
MARK 5
PSI
0 116 145 174
440 396 352 308 264 220 176 132 88 44 0 80 Limit for water like products Capacities below this line require verification by Monoflo PSI
174 145 116 87
53
26
58 29 0
50
100
Rotor Selection
250
300
350
n = corrected duty speed, no = rpm @ 0 psi, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.98
2.95
1032
590
590
590
Published information other than that marked certified is to be used as a guide only
Temperature (F)
660
GENERAL DATA
10000 1000 100 3 10 2 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph 1 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1
Light Corrosive SF SF TH TO SF HCP
5
Medium Corrosive SF HCP SF TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo. Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 8.0 8.0 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 8.0 8.0
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1BB SHAFT DIAMETER 140 mm OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1CA
CURRENT
HEAVY 1000
LIGHT 50 20 10
230
500
100
Viscosity Limits (Stokes)
PSI
29 58 87
Limit for water like products Capacities below this line require verification by Monoflo
50 Rotor Selection
100
200
250
270
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.18
4.13
885
663
663
663
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 1000 100 3 10 2 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph 1 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1
Light Corrosive SF SF TH TO SF HCP
5
Medium Corrosive SF HCP SF TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1CA SHAFT DIAMETER 140 mm OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1CB
CURRENT
LIGHT 50 20 10
230 212 176 104 68 32
500
100
Viscosity Limits (Stokes)
0 58 87
550 440 330 220 110 0 134 Limit for water like products Capacities below this line require verification by Monoflo
174
106 80 53 26 0
174
116
87 58 0
BAR
50
100
200
250
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.18
4.72
1770
1327
1327
1327
Temperature (F)
PSI
80
GENERAL DATA
10000 1000 100 3 10 2 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph 1 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1
Light Corrosive SF SF TH TO SF HCP
5
Medium Corrosive SF HCP SF TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1CB SHAFT DIAMETER 140 mm OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1DA
CURRENT
HEAVY 1000 500
Abrasion Zones
50
20
230 212 176 140 104
MARK 3
68 32
29 58 87
Limit for water like products Capacities below this line require verification by Monoflo
67 53 40 26 13 0
87 58 29 0
PSI
50
Rotor Selection
100
200
250
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.18
4.13
958
737
737
737
Published information other than that marked certified is to be used as a guide only
Temperature (F)
MARK 5
GENERAL DATA
10000 1000 100 3 10 2 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph 1 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1
Light Corrosive SF SF TH TO SF HCP
5
Medium Corrosive SF HCP SF TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1DA SHAFT DIAMETER 140 mm OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C23K
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1 0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 Temperature (F)
1000
10
PSI CONSULT MONOFLO
0 44
40 35 31
9 8 7
MARK 1
87
32
26 22 18
6 5 4
13 8 4 0
3 2 1 0 2.4
87
Limit for water like products Capacities below this line require verification by Monoflo. 3.2
73 58 44 29 15 0
1.8
2.4
1.2
1.6
0.6
0.8
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR stator material.
SLIP FACTOR (f)
0.20
0.80
11.80
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 7 6 Pump N.P.S.H. Required Meters head of water 5 4 3 2 1 0 1 2 3 4 5 Correction Factor 6 7 0 0 2 4 6 8 Pump Capacity (m/h) 9 18 26 35 Pump Capacity (gpm) 10 44 PUMP N.P.S.H(R) CURVE SIZE 3K
1000
100
10
0.1
0.01
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FITTINGS NB mm (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel COMMENTS ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
SEALING ARRANGEMENT PUMP SIZE C23K SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1XK
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10
Viscosity Limits
20
2
(Stokes)
0.01
230 212 176
12
MARK 1
0 43
140 104 68 32
44
10
35
26
17
2
Limit for water like products Capacities below this line require verification by Monoflo.
0 2
2.7
29 14
1.3
PSI
200
Rotor Selection
400
600
Pump Speed (rpm)
800
1000
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.24
0.94
22.1
Published information other than that marked certified is to be used as a guide only
43
Temperature (F)
61
14
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 7 6
Pump N.P.S.H. Required Meters head of water PUMP N.P.S.H(R) CURVE SIZE XK
1000
100
5 4 3 2
10
0.1
1 0
0 0
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 50 (2) 50 (2) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS NB BODY mm MATERIAL (inch) Cast Iron St. Steel 50 (2) 50 (2)
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1XK SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C14K
CURRENT
LIGHT 1 0.01
230 212 PSI 0 43 58 87 176 140 104 68 32
22
CONSULT MONOFLO
MARK 1
Limit for water like products Capacities below this line require verification by Monoflo.
PSI
600
800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.24
0.87
36.9
Published information other than that marked certified is to be used as a guide only
87 72 58 43 29 14 0
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5
PUMP N.P.S.H(R) CURVE SIZE 4K
1000
4
Pump N.P.S.H. Required Meters head of water
100
10
0.1
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 65 (2.5) 65 (2.5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION 90 end cover Can be rotated Can be rotated STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C14K SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C15K
CURRENT
HEAVY 500
0.01
230 212
40
CONSULT MONOFLO
PSI 0 43 58
154
35
MARK 1
110
25
88
20
66
15
44
10
22
Limit for water like products Capacities below this line require verification by Monoflo.
0 6
PSI
5 4 3 2 1 0
0 100
Rotor Selection
29 14 0
200
300
400
500
600
700
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.40
1.38
88.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 4.6 4 Pump N.P.S.H. Required Meters head of water PUMP N.P.S.H(R) CURVE SIZE 5K
1000
100
10
0.1
0 0 5 10 15 20 25 30 35 38 Pump Capacity (m/h) 44 66 88 110 132 154 167 Pump Capacity (gpm)
22
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo. STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 80 (3) 80 (3) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION 90 end cover Can be rotated Can be rotated STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C15K SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C16K
CURRENT
LIGHT 1 0.01
230 212
PSI
220
50
MARK 1
0 43 58
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
13.4
58 43 29 14 0
8 6 4 2 0
100
Rotor Selection
200
400
500
600
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.47
1.57
147.5
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 PUMP N.P.S.H(R) CURVE SIZE 6K
1000
100
10
0.1
251
ROTATING PARTS CODE GUIDE CODE ABRASION ROTOR FLEXISHAFT DRIVE SHAFT DRIVE SHAFT PINS BUSHES LEGEND COMMENTS 1 Medium BD HCP UM SX SX HCP N/A N/A Medium SF HCP UM SX SX HCP N/A N/A 3 Heavy TS HCP UM SX SX HCP N/A N/A 4 Light SF UM SF SF HCP N/A N/A 5 Medium SF HCP UM SF SF HCP N/A N/A 8
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 100 (4) 100 (4) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION 90 end cover Can be rotated Can be rotated STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C16K SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C17K
CURRENT
LIGHT 1 0.01
230 212 176 PSI 140 104 68 32 0 43 58 87 Temperature (F)
352
80
220
50
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
300
400
500
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.55
1.73
184.4
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 PUMP N.P.S.H(R) CURVE SIZE 7K 5 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0
0 10 20 30 40 50 60 70 79
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C17K SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C18K
CURRENT
LIGHT 1 0.01
230 212 176 140 104 68 Temperature (F)
100
CONSULT MONOFLO
PSI 0 43 58
90
MARK 1
80
32
264 220
176 132 88
40 30 20
Limit for water like products Capacities below this line require verification by Monoflo.
44 0
20.1
58
10
43 29
13.4
14 0
6.7
0
0 100 200 Pump Speed (rpm)
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.63
2.09
295.0
Published information other than that marked certified is to be used as a guide only
PSI
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6.5 6 5 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7
0 10 20 30 40 50 60 70 80 90 100
1000
100
10
0.1
0.01
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 125 (5) 125 (5) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C18K SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C19K
CURRENT
HEAVY 500 572 528 484 440 396 Pump Capacity (gpm) 100
LIGHT 1 0.01
230 212 Temperature (F) PSI 176 140 104 68
70 60 50 40 30 20 10 0 30
40.2 Absorbed Power (hp)
PSI Limit for water like products Capacities below this line require verification by Monoflo.
20
10
87 72 58 43 29 14 0
26.8
13.4
0
0 100 200 Pump Speed (rpm)
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
0 300 400
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.71
2.20
331.9
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
6
1000
100
Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
10
0.1
0.01
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (6) 150 (6) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C19K SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1AK
CURRENT
HEAVY 500 Viscosity Limits (Stokes)
20
10
0.01
230 212 176 Temperature (F)
792
180
CONSULT MONOFLO
704
160
PSI MARK 1
140 104 68 32
616
140
0 43 58
528
120
440
100
352
80
264
60
176
40
Limit for water like products Capacities below this line require verification by Monoflo.
88
20
0 30
PSI
58
20
43 29
26.8
10
14 0
13.4
0 0 50
Rotor Selection
100
150
200
250
300
350
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.80
2.76
442.5
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 PUMP N.P.S.H(R) CURVE SIZE AK 5 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph
1000
100
10
0.1
0
0 20 40 60 80 100 120 140 160165
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 150 (6) 150 (6) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1AK SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
COMPACT
C1BK
CURRENT
HEAVY 500 Viscosity Limits (Stokes) 1056 968 880 792 100
Limit for water like products Capacities below this line require verification by Monoflo.
PSI 58 43 29 14 0
100
200
250
270
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.98
3.86
590.0
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE BK 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000
100
10
0.1
0.01
0
0 40 80 120 160 200 225
BD: 4140 Steel; MQ: Alloy Steel; SF: 316 Stainless; SX: 304 or 410 Stainless; TO, TH & TS: Tool steel; HCP: Hard Chrome Plating; N/A: Not applicable. Check the compatibility of the material with the pumped product. If alternative materials are required please consult Monoflo.
STATOR SELECTION GUIDE Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS NB mm (inch) 200 (8) 200 (8) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN BODY MATERIAL Cast Iron St. Steel ORIENTATION OPTION STANDARD SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
Vertical Vertical
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
ORIENTATION
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1BK SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
LIGHT 50 0 2 10
230 212 176
500
Viscosity Limits
(Stokes)
140 104 68
1100 PSI 880 660 440 220 0 134 Limit for water like products Capacities below this line require verification by Monoflo
0 58 87 32
107 80 53 26 0 PSI
87 58 29 0
50
100
200
250
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.18
4.72
1770
1327
1327
1327
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 1000 100 3 10 2 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph 1 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 9 4
1
Light Corrosive SF SF TH TO SF HCP
5
Medium Corrosive SF HCP SF TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Color Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 10.0 10.0
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE C1CK SHAFT DIAMETER 140 mm OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
4 1 NOV 2006
When ordering parts you will need to have the following information ready. 1. The full parts code e.g. TS C041 2525. If the parts cannot be identified or the full parts code is unknown then other information will be needed. 2. 3. 4. 5. NOTE The pump type and order number have been inserted on the facsimile nameplate, this nameplate is fixed onto the pump in a prominent position. The actual certified pump parts list was also enclosed within the O&M instructions. This should be used in conjunction with the exploded views when ordering new parts. The pump type C14AC41RMA. The part description Rotor/Stator/Shaft etc. The material required or the rotating parts code. The pump serial number.
Published information other than that marked certified is to be used as a guide only
4 2 NOV 2006
MATERIALS PARTS IDENTIFICATION The items to be ordered can be identified in several ways. Many rotating parts will carry their parts number etched on them. The exact part number for the component used in your pump can be identified from the parts listing, which can be found inside the Operating and Maintenance Instructions booklet which accompanied your pump. An example of which is at the back of this section. If you do not know the description of your part, this again can be found using the Operating and Maintenance Instructions or the relevant section from this manual. For this you would need the typical pump drawing and the drawing reference number page. It is also possible to identify the part if you have the full pump code. Refer to the pump coding information in the relevant section in this manual. An example of how this can be done now follows. Firstly lets look at how the pump coding is drawn up. Example of Compact Range Coding Sheet follows on next page.
Published information other than that marked certified is to be used as a guide only
4 3 SEPT 2008
Range Design Mk No
Monobloc Compact Monobloc Compact Square Inlet Monobloc Monobloc (January 2007) 5.7 gpm @ 1750 rpm 14.5 gpm @ 1750 rpm 44.0 gpm @ 1500 rpm 57.2 gpm @ 1500 rpm 96.8 gpm @ 1000 rpm 162.9 gpm @ 800 rpm 250.9 gpm @ 700 rpm 347.8 gpm @ 600 rpm 427.0 gpm @ 500 rpm 550.5 gpm @ 450 rpm 726.4 gpm @ 400rpm 990.6 gpm @ 350 rpm 1937.2 gpm @ 270 rpm 1276.8 gpm @ 270 rpm Single stage Two stage Four stage Single stage - extended pitch Cast Iron Stainless steel Code 1
C S 1 2
1 2 3 X 4 5 6 7 8 9 A B C D
Size
Stages
A B D K C S 1 5 8 0 1 3 5 R M P A B H / A 1 2 3
Casing Material
Rotating Parts 1
Rotor Mk No
Mk1 (Standard) Mk3 (Temperature) Mk5 (Temperature) RA, RR etc. Mechanical Seal Packed Gland Refer to product manual section 2 & 3, drive selections
C C Range
1 Design Mk 1
X Size 0X
A Single Stage
C Cast Iron
1 Mk 1 Rotor
R Nitrile Stator
Published information other than that marked certified is to be used as a guide only
4 4 NOV 2006
The maximum number of characters in any pump coding can be fifteen. The following pump characters can be described within these limits. PUMP RANGE DESIGNATION Represents the range description. PUMP MARK NO. As modifications are made to the pump design so the mark number will be up stroked. PUMP CAPACITY OR SIZE Represents the pump size with the specified range. NO. OF STAGES Represents the number of complete stages within the rotor/stator element and would be indicated as A for single stage, B for two stage, D for four stage and K for single stage, extended pitch. PUMP BODY MATERIAL General material description of pressure boundary items i.e. suction and delivery parts. ROTATING PARTS CODE Identifies the material combination code for the main rotating parts in contact with the fluid being pumped. ROTOR MARK NO. Identifies standard or temperature variant rotor. STATOR MATERIAL Identifies the stator material by using the second letter of any standard resilient stator material code i.e. A for RA. SEALING ARRANGEMENT Identifies mechanical seal or packed gland. BUILD OPTION Identifies drive interface to suit drive type required. OBLIQUE SYMBOL(/) The oblique symbol separates the basic pump code from the standard variation code.
Published information other than that marked certified is to be used as a guide only
4 5 NOV 2007
THE STANDARD VARIATION CODE The standard variation code identifies one or more design features that are different from the standard pump build. This code is used to specify features that will be built into the pump to satisfy the customer specification. Each pump coding system is designed to suit the characters for each range and inevitable there is limited consistency across the range of pump systems. The example pump code we will be looking at is C14AC41RMA. The First Position C = Compact Range. The Second Position 1 = Design Mark 1. Third and Fourth 4A = The pump size and no. of stages in this case size four single stage. Fifth Position C = Material of construction - in this case cast iron. The Sixth Position 4 = The rotating parts code in this case code 4. With this number we are able to specify the correct parts number for all rotating parts.
Published information other than that marked certified is to be used as a guide only
4 6 NOV 2006
Seventh Position 1 = The rotor mark number in this case mark 1. Eighth Position R = The stator material in this case RR (Nitrile Rubber). Ninth Position M = Seal type in this case mechanical seal. Tenth Position A = Build option. This identifies the drive interface with regard to shaft diameter, flange sizes etc.
Published information other than that marked certified is to be used as a guide only
4 7 NOV 2006
PUMP = Compact
Quantity Per Pump 4 4 8 4 1 2 2 3 1 1 1 1 1 1 1 3 4 4 4 4 4 4 1 1 1 4 4 4 4 4 4 4 4 1 0.5 0.5 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 4 14 20 14 1 2 4 4 4 4
4 8 NOV 2006
PARTS NUMBERING SYSTEM The part numbers are made up of four descriptive fields:1. 2. 3. 4. 1. 2. 3. Material Pump Range and Size Item Classification Number Variation Code The material code will be 2 characters i.e. SF, MM, MB. The pump range and size will consist of four characters i.e. C041. The item classification will consist of two numbers and these numbers indicate the standard component.
i.e. 22 = Stator 25 = Rotor 32 = Shaft etc. (See Appendix A) 4. The last two characters the variation code generally indicates the variance from the standard component.
Published information other than that marked certified is to be used as a guide only
4 9 NOV 2006
Published information other than that marked certified is to be used as a guide only
4 10 NOV 2007
MATERIALS MATERIAL CODES Listed below a general list of materials used in the pumps, these are the main materials with high usage and are for a guide only, this is not a complete list and if you have any problems or queries you should contact Monoflo. Description BD CD MQ SB SF ST SX TH TO ZG Alloy Steel Cast Iron Alloy Steel Stainless Steel Stainless Steel Cast Stainless Steel Stainless Steel Tool Steel Tool Steel Gasket Material
Published information other than that marked certified is to be used as a guide only
4 11 NOV 2007
MATERIALS STATORS CODE RA RE RH RJ RR RV DESCRIPTION Black Natural Rubber Grade A Ethylene Propylene Rubber (EPR) Chlorosulponated P.E. (CSM) High Nitrile Rubber Nitrile Rubber (NBR) Fluoroelastomer (FKM) MAXIMUM TEMP F 158 266 230 230 230 302
Published information other than that marked certified is to be used as a guide only
4 12 NOV 2006
Operating and Maintenance Instructions will be supplied with your pump. Additional copies can be obtained by contacting your Monoflo Representative.
Published information other than that marked certified is to be used as a guide only
SECTION 5-1 SECTION 5-2 SECTION 5-3 SECTION 5-4 SECTION 5-5 SECTION 5-6 SECTION 5-7 SECTION 5-8 SECTION 5-9
Materials of Construction General Arrangements Gland Section Dimensions Packing / Seal Details Flange Dimensions Rotor Dimensions Stator Dimensions Gearbox Cross Drilling Differential and Discharge Pressure
MATERIALS OF CONSTRUCTION
COMPONENT BODY GLAND FOLLOWER SUCTION CHAMBER SUCTION CHAMBER EXTENSION 01A 08A 23A CAST IRON CAST IRON CAST STAINLESS STEEL CAST IRON STAINLESS STEEL CAST STAINLESS STEEL CAST IRON STAINLESS STEEL CAST STAINLESS STEEL CAST IRON SPHEROIDAL CAST IRON STAINLESS STEEL CAST STAINLESS STEEL ALLOY STEEL STAINLESS STEEL CARBON STEEL STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CAST IRON CAST STAINLESS STEEL MATERIAL CD CD ST CD SF ST CD SF ST CD CF SF ST *BD *SF MQ SF *SF *SX CD ST SPEC BS EN 1561 BS EN 1561 BS 3100 BS EN 1561 BS EN 10088 BS 3100 BS EN 1561 BS EN 10088 BS 3100 BS EN 1561 BS 2789 BS EN 10088 BS 3100 ASTM A322 BS EN 10088 BS EN 10277 BS EN 10088 BS EN 10088 BS EN 10088 BS EN 1561 BS 3100 DESCRIPTION/GRADE E N- G JL - H B 1 9 5 EN-GJL-HB195 316C16F EN-GJL-HB195 X2CrNiMo17-12-2 316C16F EN-GJL-HB195 X2CrNiMo17-12-2 316C16F EN-GJL-HB195 400/18 or 420/12 X2CrNiMo17-12-2 316C16F 4140 X2CrNiMo17-12-2 20NiCrMoS2-2 X2CrNiMo17-12-2 X2CrNiMo17-12-2 X2CrNi18-9 or X12Cr13 EN-GJL-HB195 316C16F
23B
END COVER
24A
Published information other than that marked certified is to be used as a guide only
COMPACT ALL 2
Published information other than that marked certified is to be used as a guide only
MODEL C21B C21D C22A C22B C22D C23K C23A C23B MODEL C21B C21D C22A C22B C22D C23K C23A C23B All dimensions in inches Note:
A 16.89 22.56 16.89 22.56 37.76 20.47 26.18 26.18 J1 1.54 1.54 1.54 1.54 1.54 1.54 1.54 1.54
B 11.65 440 296 440 822 383 528 528 J2 11.69 17.36 11.69 17.36 32.40 15.12 20.83 20.83
C 5.24 5.24 5.24 5.24 5.39 5.39 5.39 5.39 K 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59
D 1 " 1 " 1 " 1 " 1 1 1 1 K1 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24
E 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 L 3.94 3.94 3.94 3.94 3.94 3.94 3.94 3.94
F 11.61 17.28 11.61 17.28 32.32 15.04 20.75 20.75 L1 2.36 2.36 2.36 2.36 2.91 2.91 2.91 2.91
H1 3.15 3.15 3.15 3.15 3.94 3.94 3.94 3.94 N 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35
J 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 P 5.67 5.67 5.67 5.67 5.83 5.83 5.83 5.83
D is British Standard pipe (B.S.P. or NPT) designation Rp Q and Q1 are bolt diameters * Refer to section 5-2, page 1
Published information other than that marked certified is to be used as a guide only
D1
MODEL C13D C2XA C2XB C1XD C14A C14B C14D C15A C15B C15D C16A C16B C16D C17A C17B C17D C18A C18B C18D C19A C19B C1AA C1AB C1BA MODEL C13D C2XA C2XB C1XD C14A C14B C14D C15A C15B C15D C16A C16B C16D C17A C17B C17D C18A C18B C18D C19A C19B C1AA C1AB C1BA
A 45.67 22.28 29.49 53.66 30.75 38.82 57.56 33.15 45.63 69.92 37.80 53.35 85.67 43.71 58.18 103.39 49.05 68.58 109.68 54.88 73.07 58.11 85.00 70.63 K 0.63 0.59 0.59 0.71 0.63 0.63 0.71 0.63 0.71 0.91 0.71 0.91 0.87 0.91 0.91 1.18 0.91 0.87 1.18 0.87 0.87 0.87 1.18 1.18
B 36.61 16.10 23.31 42.76 21.69 29.76 46.65 24.49 34.72 57.36 28.50 40.79 71.18 32.68 47.17 87.56 38.03 54.10 93.86 42.48 60.67 45.71 69.13 53.78 K1 0.24 0.24 0.24 0.24 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.87 0.31 0.31 0.87 0.31 0.31 0.31 0.31 0.31
C 9.06 6.18 6.18 10.91 9.06 9.06 10.91 8.66 10.91 12.56 9.29 12.56 14.53 11.06 11.06 15.83 11.06 14.49 15.83 12.40 12.40 12.40 15.83 16.81 L 3.94 3.94 3.94 4.33 3.94 3.94 4.33 3.94 4.33 5.51 4.33 5.51 6.30 5.51 5.51 9.06 5.51 6.30 9.06 6.30 6.30 6.30 9.06 9.06
D 2.56 1.97 1.97 3.15 2.56 2.56 3.15 3.15 3.15 3.94 3.94 3.94 4.92 4.92 4.92 5.91 4.92 4.92 5.91 5.91 5.91 5.91 5.91 8.87 L1 2.91 3.15 3.15 3.15 3.94 3.94 3.94 3.94 3.94 5.12 3.94 5.12 5.51 5.12 5.12 5.71 5.12 5.51 6.69 7.87 7.87 7.87 7.87 7.87
D1 1.96 1.96 1.96 1.96 2.55 2.55 3.14 3.14 3.14 3.93 3.93 3.93 4.92 4.92 4.92 4.92 4.92 4.92 5.90 5.90 5.90 5.90 5.90 7.87
E 5.75 3.54 3.54 5.98 5.75 5.75 5.98 5.75 5.98 7.01 5.98 7.01 7.68 7.01 7.01 220 7.01 7.68 220 7.68 7.68 7.68 8.46 8.46 M 5.51 4.72 4.72 6.30 5.51 5.51 6.30 5.51 6.30 7.09 6.30 7.09 7.87 7.09 7.09 11.02 7.09 7.87 11.02 7.87 7.87 7.87 11.02 11.02
F 37.36 16.61 23.82 44.53 22.83 30.91 48.70 25.16 37.40 59.84 29.49 44.02 74.53 34.17 48.66 91.14 39.53 58.39 98.66 43.66 61.85 46.89 72.80 60.39 M1 3.94 4.33 4.33 4.33 5.12 5.12 5.12 5.12 6.06 6.30 6.06 6.06 7.09 6.69 6.69 7.40 6.69 7.09 8.66 9.45 9.45 9.45 10.24 10.24 N 4.41 3.35 3.35 4.92 4.41 4.41 4.92 4.41 4.92 5.91 4.92 5.91 6.30 5.91 5.91 8.86 5.91 6.30 8.86 6.30 6.30 6.30 8.86 8.86
H 1.57 1.57 1.57 1.57 1.57 1.57 1.77 1.57 2.36 1.77 2.36 2.36 2.17 1.97 1.97 3.54 1.97 2.76 3.43 2.76 2.76 2.76 2.76 3.94
1.26 1.10 1.10 1.50 1.26 1.26 1.50 1.26 1.50 1.73 1.50 1.73 1.85 1.73 1.73 2.32 1.73 1.85 2.32 1.85 1.85 1.85 2.32 2.32 P 8.94 7.48 7.48 9.65 8.94 8.94 9.65 9.13 9.65 11.02 10.04 11.02 12.60 12.20 12.20 16.14 12.20 12.60 16.14 13.58 13.58 13.58 16.14 17.72
J1 3.15 1.54 1.54 2.87 3.15 3.15 2.87 3.15 2.87 3.39 2.87 3.39 3.78 3.39 3.39 3.94 3.39 3.78 3.94 3.78 3.78 3.79 3.94 3.94 Q M10 M8 M8 M12 M10 M10 M12 M10 M12 M12 M12 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
J2 37.76 16.69 23.90 45.20 23.03 31.10 49.13 25.35 37.44 60.63 29.53 44.33 75.20 34.68 49.17 93.78 40.04 58.66 100.08 43.94 62.13 47.17 73.42 61.61 Q1 M8 M8 M8 M8 M10 M10 M12 M10 M12 M12 M12 M12 M16 M12 M12 M16 M12 M16 M20 M16 M16 M16 M20 M20
All dimensions in inches Note: Q and Q1 are bolt diameters * Refer to section 5-2, page 1
Published information other than that marked certified is to be used as a guide only
MODEL C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK MODEL C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK All dimensions in inches Note:
A 29.53 38.82 43.39 50.08 58.19 65.12 73.07 79.02 95.94 K 0.59 0.63 0.63 0.71 0.91 0.91 0.87 0.87 1.18
B 23.35 29.76 34.72 40.79 47.17 54.09 60.67 66.61 79.09 K1 0.24 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31
C 6.18 9.06 8.66 9.29 11.06 11.02 12.40 12.40 16.81 L 0.39 3.94 3.94 4.33 5.51 5.51 6.30 6.30 9.45
D 1.97 2.56 3.15 3.94 4.92 4.92 5.91 5.91 7.87 L1 3.15 3.94 3.94 3.94 5.12 5.12 7.87 7.87 7.87
E 3.66 5.75 5.75 5.98 7.01 7.01 7.68 7.68 8.46 M 4.72 5.51 5.51 6.30 7.09 7.09 7.87 7.87 11.02
F 23.86 30.91 35.39 41.77 48.66 55.59 61.85 67.80 85.71 M1 4.33 5.12 5.12 6.06 6.69 6.69 9.45 9.45 11.02
H 1.57 1.57 1.57 2.36 1.97 1.97 2.76 2.76 3.94 N 3.35 4.41 4.41 4.92 5.91 5.91 6.30 6.30 8.86
J 1.10 1.26 1.26 1.50 1.73 1.73 1.85 1.85 2.32 P 7.48 8.94 9.13 10.04 12.20 12.20 13.58 13.58 17.72
J1 1.54 3.15 3.15 2.87 3.39 3.39 3.78 3.78 3.94 Q M8 M10 M10 M12 M16 M16 M16 M16 M16
J2 23.94 31.10 35.59 41.81 49.17 56.10 62.13 68.07 86.93 Q1 M8 M10 M10 M12 M12 M12 M16 M16 M20
Published information other than that marked certified is to be used as a guide only
MODEL S14A S14K S15A S15K S16A S16K S17A S17K S18A S18K MODEL S14A S14K S15A S15K S16A S16K S17A S17K S18A S18K All dimensions in inches Note:
A 30.75 38.82 33.15 43.39 37.80 50.08 43.70 58.19 49.05 65.12 K 0.63 0.63 0.63 0.63 0.71 0.71 0.91 0.91 0.91 0.91
B 20.71 28.78 23.11 33.35 26.54 38.82 30.59 45.08 35.91 51.97 K1 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31
C 10.04 10.04 10.04 10.04 11.26 11.26 13.11 13.11 13.15 13.15 L 3.94 3.94 3.94 3.94 4.33 4.33 5.51 5.51 5.51 5.51
D 6.50 x 6.50 6.50 x 6.50 6.50 x 6.50 6.50 x 6.50 7.87 x 7.87 7.87 x 7.87 9.45 x 9.45 9.45 x 9.45 9.45 x 9.45 9.45 x 9.45 L1 3.94 3.94 3.94 3.94 3.94 3.94 5.51 5.51 5.51 5.51
E 5.75 5.75 5.75 5.75 5.98 5.98 7.01 7.01 7.01 7.01 M 5.51 5.51 5.51 5.51 6.30 6.30 7.09 7.09 7.09 7.09
F 22.83 30.91 25.16 35.39 29.49 41.77 34.17 48.66 39.53 55.59 M1 5.12 5.12 5.12 5.12 6.06 6.06 6.69 6.69 6.69 6.69
H 1.57 1.57 1.57 1.57 2.36 2.36 1.97 1.97 1.97 1.97 N 4.41 4.41 4.41 4.41 4.92 4.92 5.91 5.91 5.91 5.91
J 1.26 1.26 1.26 1.26 1.50 1.50 1.73 1.73 1.73 1.73 P 9.29 9.29 9.29 9.29 10.24 10.24 12.20 12.20 12.20 12.20
J1 3.15 3.15 3.15 3.15 2.87 2.87 3.39 3.39 3.39 3.39 Q M10 M10 M10 M10 M12 M12 M16 M16 M16 M16
J2 23.03 31.10 25.35 35.59 29.53 41.81 34.68 49.17 40.04 56.10 Q1 M10 M10 M10 M10 M12 M12 M12 M12 M12 M12
Published information other than that marked certified is to be used as a guide only
COMPACT
5-2 6
ALL CURRENT
SEPT 2008
P N
K2
K1
J3 Q1 Q1
J2 Q
J1
M2
M1
L1
L1
H G F1
H F E
A1 10.0 9.8
C 22.9 25.8
D 7.8 9.8
F 34.9 36.8
H 3.9 4.3
J1
J2 36.9 36.8
11.2
3.3
4.7
K1
K2
L1 8.6 10.6
M1 11.0 13.3
M2 11.4 13.3
P 18.7 20.1
Q1
1.5
0.3
0.8
11.0
14.1
9.8
M24
M20
Published information other than that marked certified is to be used as a guide only
COMPACT
5-2 7
ALL CURRENT
SEPT 2008
P N
K2
K1
J3 Q1 Q1
J2 Q
J1
J T
M2
M1
L1
L1
H2 G F1
H2 F
H1 E
H U
A1 10.0 9.8
D 7.87 9.8
F 35.9 37.7
H1
H2 100 110
J 30 108 30
J1
J2 929 927
3.0
235
25
K1
K2
L1 8.6 10.6
M1 11.0 13.3
M2 11.4 13.3
P 18.7 20.1
Q1
0.3
0.8
10.6
12.9
9.8
M20
M20
136
184
75
215
Published information other than that marked certified is to be used as a guide only
Pump Size C21B C21D C22A C22B C22D C23A C23B C23K C2XA C2XB
Drive Type
Shaft Diameter mm
Pin Joint
32
M032139G
1.40
0.28
0.53
45
M045139G
1.46
0.31
1.73
NOTE: All seal working lengths are to DIN L1K dimensions. This table is not to be used for standard or DIN L1N working length seals. All seals use M type seat except for 85mm which uses BS type. This table is not necessarily compatible with any other seal type - check with Monoflo Technical Dept.
Published information other than that marked certified is to be used as a guide only
Pump Size
Drive Type
Shaft Diameter mm 32
C1XK C13D C14K C14A C14B C15K C15A C1XD C14D C15B C16K C16A C15D C16B C17K C17A C17B C18K C18A C16D C18B C19K C19A C19B C1AK C1AA C17D C18D C1AB C1BK C1BA
Pin Joint
M032139G
Pin Joint
45
M045139G
1.46
0.31
1.61
Pin Joint
55
M055139G
1.48
0.39
1.36
Pin Joint
65
M065139G
1.59
0.47
1.32
Pin Joint
85
M085139G
1.87
0.49
1.30
Pin Joint
85
M085139G
1.87
0.49
2.28
NOTE: All seal working lengths are to DIN L1K dimensions. This table is not to be used for standard or DIN L1N working length seals. All seals use M type seat except for 85mm which uses BS type. This table is not necessarily compatible with any other seal type - check with Monoflo.
Published information other than that marked certified is to be used as a guide only
E CRS F
H APPROX. TO OBSTRUCTION
PUMP C21B C21D C22A C22B C22D C23A C23B C23K C2XA C2XB C13D C1XB C14K C14A C14B C15K C15A C1XD C14D C15B C16K C16A C15D C16B C17K C17A C17B C18K C18A C16D C18B C19K C19A C19B C1AK C1AA C17D C18D C1AB C1BK C1BA
C1BB C1CA C1CB C1CK C1DA
B (mm)
1.89
32
2.36
1.73
2.80
3.39
0.35
1.57
2.56
45
3.07
2.56
3.94
4.80
0.43
1.57
2.95
55
3.58
2.56
4.60
5.51
0.43
1.81
3.54
65
4.17
3.23
5.28
6.02
0.51 0.51
1.50
4.33
85
5.12
3.23
6.30
7.40
0.51 0.51
1.38
4.52
85
5.70
3.85
6.77
7.87
0.51 0.51
3.74
(BLOC)
(BARESHAFT)
Published information other than that marked certified is to be used as a guide only
Pump Model(s) C21B C21D C22A C22B C22D C23K C23A C23B C2XA C2XB C1XK C13D C14A C14B C14K C15A C15K C1XD C14D C15B C16A C16K C15D C16B C17A C17B C17K C18A C18K C16D C18B C19A C19B C19K C1AA C1AK C17D C18D C1AB C1BA C1BK C1BB C1CA C1CB C1CK C1DA
0.39
0.49 0.59
0.59
Published information other than that marked certified is to be used as a guide only
COMPACT
5-5 1
ALL CURRENT
SEPT 2008
ANSI FLANGE DIMENSIONS SINGLE & TWO STAGE MODELS PLUS C21D & C22D (INCH)
B E G F A C H
DIA D
Pump Construction
Pump Model(s) C21B C21D C22A C22B C22D C23A C23B C23K C1XK C2XA C2XB C14A C14B C14K C15A C15B C15K
Dimensions A B C
(Number)
H 1 1
2 3 ANSI B16-1 Class 125 4 6 8 8 9 NPT THREAD 2 3 ANSI B16-5 Class 150 4 6 10 12 10
0.62 (4) 0.75 (4) 0.75 (4) 0.88 (8) 0.88 (8) 0.88 (8) 0.98 (12)
Cast Iron
C16A C16B C16K C17A C17B C17K C18A C18B C18K C19A C19B C19K C1AA C1AB* C1AK* C1BA* C1BK* C1BB* C1CA* C1CB* C1CK* C1DA* C21B C21D C22A C22B C22D C23A C23B C23K C1XK C2XA C2XB C14A C14B C14K C15A C15B C15K
6 7.5 9 11 13.5 16 16
0.75 (4) 0.75 (4) 0.75 (8) 0.75 (8) 0.75 (8) 1.0 (12) 1.0 (12)
Stainless Steel
C16A C16B C16K C17A C17B C17K C18A C18B C18K C19A C19B C19K C1AA C1AB* C1AK* C1BA* C1BK* C1BB* C1CA* C1CB* C1CK* C1DA*
Published information other than that marked certified is to be used as a guide only
COMPACT
5-5 2
ALL CURRENT
MAY 2008
B E G F A C
DIA D
Pump Models
Dimensions (inches) A 3 4 6 8 2 3 4 6 8 3 4 6 8 2 3 4 6 8 B 7.5 9 11 13.5 6.5 8.25 10 12.5 15 7.5 9 11 13.5 6.5 8.25 10 12.5 15 C D (N u m b e r) E F 0.75 0.95 0.98 1.1 0.87 1.18 1.34 1.54 1.69 0.95 0.95 0.98 1.1 0.87 1.18 1.34 1.54 1.69 G
C13D C1XD C14D C15D C 16D C17D C18D C13D C1XD Cast Iron C14D Discharge C15D Flange C16D C17D C18D C13D C1XD C14D Stainless Steel C15D Suction Flange C16D C17D C18D C13D C1XD Stainless Steel C14D Discharge C15D Flange C16D C17D C18D
All dimensions in inches.
6 0.75 (4) 7.5 0.75 (8) 9.5 0.87 (8) 11.75 0.87 (8) 5 0.75 (8) 4.17 6.6 0.87 (8) 5.71 7.87 0.87 (8) 7 10.6 0.87 (12) 9.69 13 1 (12) 11.81 6 0.75 (4) 5 7.5 0.75 (8) 6.18 9.5 0.87 (8) 8.5 11.75 0.87 (8) 5 0.75 (8) 3.62 6.6 0.87 (8) 5 7.87 0.87 (8) 6.18 10.6 0.87 (12) 8.5 13 1 (12) 10.63
0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
Published information other than that marked certified is to be used as a guide only
Extended Pitch Pump C23K C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK C1CK L 13.86 13.86 16.81 16.81 18.39 18.39 23.39 23.39 28.07 28.07 32.68 32.68 36.10 36.10 40.31 40.31 46.73 46.73 58.66 58.66 74.80 Weight lbs 3.2 3.2 6.0 2.7 10.6 4.8 7.4 16.3 34.8 15.8 55.6 25.2 34.5 76.1 49.4 108.9 74.3 163.8 131.1 289.0 573.2
Single Stage Pump C22A C23A C2XA C14A C15A C16A C17A C18A C18A C19A C19A C1AA C1AA C1BA C1BA C1CA C1CA C1DA L 184 7.24 205 8.07 9.57 243 284 11.18 346 13.62 419 16.50 482 18.98 528 20.79 593 23.35 678 26.69 33.83 40.90 53.12 Weight lbs 0.4 0.9 1.5 3.3 1.6 3.4 2.8 6.2 5.4 11.9 9.3 20.5 14.7 32.4 19.9 43.9 28.5 62.8 43.6 96.1 165.7 286.6 379.1
Two Stage Pump C21B C22B C23B C2XB C14B C15B C16B C17B C18B C19B C1AB C1BB C1CB L 184 7.24 12.99 330 13.86 352 18.35 466 19.33 491 24.45 621 733 28.86 33.46 850 948 37.32 41.54 10551 48.19 1224 60.07 74.80 Weight lbs 0.43 0.9 0.75 1.7 3.3 1.48 10.4 4.7 5 11.0 10.1 22.3 17 37.5 59.7 27.1 37.6 82.9 116.0 1 183.0 83 293.2 573.2
Four Stage Pump C21D C22D C23D C2XD C14D C15D C16D C17D C18D L 328 12.91 641 25.24 25.98 660 825 32.48 924 36.38 1159 45.59 54.53 1385 64.69 1643 70.63 1794 Weight lbs 0.76 1.7 1.58 3.5 6.3 2.88 5.51 12.1 9.15 20.2 17.98 39.6 66.5 30.15 108.1 49.04 146.2 66.3
Published information other than that marked certified is to be used as a guide only
STATOR IDENTIFICATION
DIA B
Extended Pitch Pump C23K C1XK C14K C15K C16K C17K C18K C19K C1AK C1BK C1CK A 11.34 14.29 17.09 21.65 25.94 30.59 33.94 38.23 44.05 53.31 68.77 B 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.75 12.75
Weight lb 5.7 12.1 15.4 28.7 50.7 79.4 103.6 190.0 170.0 293.2 410.0
Single Stage Pump C22A C23A C2XA C14A C15A C16A C17A C18A C19A C1AA C1BA C1CA C1DA A 5.47 5.63 7.09 9.02 11.42 13.66 16.10 17.87 20.04 23.15 27.99 34.99 46.06 B 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.75 12.75 12.75
Weight lb 2.9 2.9 6.2 8.8 15.4 24.3 39.7 52.9 97.0 90.4 152.1 202.8 264.5
Two Stage Pump C21B C22B C23B C2XB C14B C15B C16B C17B C18B C19B C1AB C1BB C1CB A 5.47 11.14 11.34 14.30 17.09 21.65 25.94 30.59 33.94 38.23 44.05 53.50 68.77 B 2.24 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.74 12.75
Weight lb 2.9 6.0 5.7 12.1 15.4 28.7 50.7 79.4 103.6 189.6 169.8 403.4 410.0
Four Stage Pump C21D C22D C13D C1XD C14D C15D C16D C17D C18D A 11.14 22.44 23.11 28.98 33.15 42.13 50.55 59.61 66.10 B 2.24 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09
Weight lb 5.7 12.1 11.66 24.64 17.16 57.2 101.2 151.8 204.6
All dimensions in inches Note: The above dimensions and weights being approximate only, are intended to serve as a guide to component identification where this is in doubt.
Published information other than that marked certified is to be used as a guide only
0.07 A
D H P.C.D.
Aj6
Fj6
ANTI-PISTONING GROOVE, 0.5mm DEEP OVER LENGTH C (POSITION AROUND SHAFT OPTIONAL). NOTE: THIS FEATURE IS NOT REQUIRED IF EXISTING KEYWAY IS SUPPLIED (SEE NOTE ABOVE) B* NOTE: *DIM B REPRESENTS LENGTH OF SHAFT FROM FLANGE TO FACE & MINIMUM WORKING LENGTH OF SHAFT AT DIAMETER A NOTE: FACE MOUNT OPTIONS CAN BE OFFERED (Eg D80C FACE MOUNT) IF FLANGE NOT AVAILABLE. Pump Body Pump Size Aj6 B C D H11 E 120 C21B C21D C22A C22B C23K C23A C23B C1XK C2XA C2XB 19 40 180.1 6 140 160 120 20 40 180.1 6 140 160 Fj6 80 95 110 80 95 110 G 2.5 3.0 3.5 2.5 3.0 3.5 C
EQUI-SP
J 4 OFF
J 7 or 8 9 or 10 9 or 10 7 or 8 9 or 10 9 or 10
Build Ref. M G F E B A
Published information other than that marked certified is to be used as a guide only
0.1 A
D H P.C.D.
Ak6
Fj6
ANTI-PISTONING GROOVE, 0.5mm DEEP OVER LENGTH C (POSITION AROUND SHAFT OPTIONAL).
NOTE: *DIM B REPRESENTS LENGTH OF SHAFT FROM FLANGE FACE & MINIMUM WORKING LENGTH OF SHAFT AT DIAMETER A B*
EQUI-SP
I 4 OFF
Pump Body
Pump Size C13D C14B C14A C14K C15A C15K C1XD C16K C14D C16A C15B C15D C17B
A k6
D H11
E 200
J 11 or 12 9 or 10 11 or 12 14 14
Build Ref. A B A B A
30
80
550.1
30
80
550.1
11.2
C16B C18K C17K C18A C17A C16D C19B 40 100 600.1 14.2
250
180
215
14
65
0105
C18B C1AK C19K C1AA C19A C17D C1BK C18D C1BA C1AB C1BB C1CA C1CB C1CK C1DA
4 4 4 4 5 5
14 14 14 18 18 (8 off) 18
85 85 85 85 140 140
A B A B A B
60 90 75
700.1 55 50
Published information other than that marked certified is to be used as a guide only
PUMP
COMPACT CURRENT
VOLUME
COMPACT MAXIMUM DIFFERENTIAL AND DISCHARGE PRESSURES FOR BRITISH STANDARD PORT FITTINGS AS SHOWN FOR EACH PUMP MODEL & SIZE
MAX. DIFFERENTIAL PRESSURE - PSI SOG Stages Pump Size 1 2 3 X 4 5 6 7 8 9 A B C D 87 87 87 87 87 87 87 87 87 87 87 87 87 174 174 174 174 174 174 174 174 174 174 174 174 174 348 348 348 348 348 348 348 348 348 65 65 58 58 58 58 58 58 58 58 58 58 58 130 130 130 58 58 58 58 58 58 58 58 58 58 232 232 232 232 232 232 232 232 232 232 232 232 145 145 145 145 145 145 145 145 145 145 232 232 232 232 232 232 232 232 232 232 232 232 232 363 363 363 363 363 363 363 363 363 232 232 58 58 58 58 58 58 58 58 58 58 58 232 232 232 58 58 58 58 58 58 58 58 58 58 232 232 232 232 232 232 232 232 232 1 2 4 1 DOG 2 4 1 MAX. DISCHARGE PRESSURE - PSI SOG 2 4 1 DOG 2 4
NOTE 1) Figures shown are based on temperatures of 68f. If operating temperatures are excessive (above 122F) contact Monoflo to confirm pressure ratings. 2) SOG : Suction on Gland DOG : Delivery on Gland 3) For the optional port fittings contact Monoflo to confirm maximum pressure ratings when high temperatures are experienced.
Published information other than that marked certified is to be used as a guide only
COMPACT
K BUILD ONLY
CURRENT
MAX. DISCHARGE PRESSURE SOG 232 232 145 116 116 145 116 145 116 116 58 DOG 232 58 58 58 58 58 58 58 58 58 58
Published information other than that marked certified is to be used as a guide only
Epsilon Range
Typical Applications
A range of technically engineered progressing cavity pumps, designed to give least whole life costs and reduced spares requirements.
Capacity up to 1850 gpm Digested sewage sludge, primary and secondary sludge Pressure up to 350 psi Mineral processing Industrial chemicals, detergents, Temperature 14oF up to 230oF polyethylene glycol Crude oil, hydraulic oil, waste oil Starches, liquified potato peel, cocoa butter Kaolin slurry, coating slurry, natural and synthetic latex Mine water
PowerDrive transmission
IO
WARR
Wearing components are eliminated between the drive end and the pumping element, offering you increased reliability. No lubrication is needed, therefore product contamination is eliminated. Pump lifetime cost is reduced due to lower spares costs. A shorter PowerDrive is available where space saving is a priority. Monoflos PowerDrive is backed by a 10 year warranty. Minimizes overall dimensions, giving you a shorter pump length. Eliminates the need for coupling and guard. A large number of Epsilon components are interchangeable with the Compact C Range, reducing inventory holding. Available in cast iron or stainless steel, with a choice of rotor and stator materials to suit individual applications e.g. hard chrome plated rotor or natural rubber stator. Reduced wear for a longer working pump life which extends the periods between routine maintenance. Think of the savings that could be realized on abrasive applications. Minimizes shear and crush damage to the pumped product, whilst maintaining a steady flow when pumping products with a high solids content. Rotors can be supplied with Monoflos range of specialized coatings to help extend the life of the rotors through improved wear and corrosion resistance Can offer considerable project cost savings by utilizing small bore pipework and eliminating the need for a series of pumps, when pumping over long distances or with high head requirements. Available for applications where rag content is a problem. Specially selected fixed and variable speed drives for longer life, due to flange mounted drive.
Bloc construction Interchangeable components Materials of construction Low running speeds Gentle pumping action Duracoat coating High pressure / long haul pumping Inspection cover Robust drives
NT
Y E AR
Performance Data
MODEL MODEL SIZE SIZE 991 12K E1BK 727 550 427 348 E17K 250 253 E16K E18 218 E17 156 E16 113 E15 E14K 44 63 E14 50 E1X 26 E13 E13K 15 E12 7 E11 0 0 58 87 0 0 87 175 350 E1AK E19K E18K 414 E1A 315 E19 MODEL SIZE K BUILD 1850 E1E 1277 E1D 925 E1C 616 E1B NUMBER OF STAGES SINGLE TWO FOUR
CAPACITY GPM
163 E15K 97
CAPACITY GPM
*E1BB models and above, and various 4 stage options are bareshaft and not available on a form folded baseplate. For guidance in selecting a pump or the dimensions for 4 stage and large Epsilon models, please contact Monoflo.
DIFFERENTIAL PRESSURE-PSI
DIFFERENTIAL PRESSURE-PSI
Dimensions
SMALL EPSILON MODELS - STANDARD POWERDRIVE MODEL E11B E11D E12A E12B E12D E13K E13A E13B E1XA LENGTH WIDTH HEIGHT 45 51 45 51 66 53 47 53 50 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 F&G 11/4 11/4 11/4 11/4 11/2 11/2 11/2 11/2 2 SHORT POWERDRIVE MODELS MODEL LENGTH WIDTH HEIGHT F & G E14A E14B E14K E15A E15B E15K E16A E16B E16K E17A E17B E17K E18A E18B E18K E19A E19B E19K E1AA E1AB E1AK E1BA E1BK 65 78 73 72 89 82 82 112 94 101 121 115 146 134 124 120 139 139 129 159 150 146 170 14 17 14 14 17 17 17 20 17 17 20 20 20 20 20 20 20 20 25 20 20 20 20 19 19 19 19 19 19 19 24 19 23 24 24 23 26 24 26 26 26 26 29 26 29 29 3 3 3 3 3 3 4 4 4 6 6 6 6 6 8 8 8 8 8 8 8 8
Brochure AllEpsilon dimensions in inches and for guidance only. Flanges to ANSI B16.1, B16.5 and NPT pipe thread.
STANDARD POWERDRIVE MODELS MODEL LENGTH WIDTH HEIGHT F & G E14A E14B E14K E15A E15B E15K E16A E16B E16K E17A E17B E17K E18A E18B E18K E19A E19B E19K E1AA E1AB E1AK E1BA E1BK 74 86 82 80 98 91 91 125 103 114 133 130 119 149 136 136 154 154 145 172 166 161 183 14 17 14 14 17 17 17 20 17 17 20 20 20 20 20 20 20 20 25 20 20 20 20 19 19 19 19 19 19 19 24 19 23 24 24 23 26 24 26 26 26 26 29 26 29 29 3 3 3 3 3 3 4 4 4 6 6 6 6 6 6 8 8 8 8 8 8 8 8
Length F
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-E Flyer Rev1 Monoflo and PowerDrive are registered trademarks of Mono Pumps Ltd.
Width
Height
EPSILON
ALL 1
INDEX 1
Dec 2007
This product manual contains selection guidelines, performance data and general data for the Monoflo Epsilon Range of progressing cavity pumps.
Section 1:
Pump and Drive Selection Procedure for Epsilon (inc K Build) Range Models.
Section 2:
Performance and General data for each model size for one, two and four stage pumps where appropriate.
Section 3:
Section 4:
Section 5:
Technical Manual.
Section 6:
Vertical Pumps
EPSILON
ALL CURRENT SELECTION PROCEDURE
1 1
Dec 2007
PUMP SIZING 1 From the pre-selection table (page 5) select the pump model which initially meets the required capacity / pressure criteria. (Refer to NOTES on page 4) 2 Referring to the performance data in sections 2 & 3 if particle size is a factor then refer to the table labelled SOLIDS HANDLING (inches) on the performance graph to verify the pumps suitability. 3 If variable speed is required then select at maximum capacity. 4 On the y-axis (Capacity) identify the required flow then move horizontally until intersection at the required differential pressure.(see 5). 5 Slip Correction for Viscosity a) If Viscosity is equal to or greater than six (6) stokes then select on the zero PSI pressure line to determine the pump speed required for the duty. From the point of intersection on the curve move vertically down to the x-axis labelled Speed to obtain the required RPM. b) If the viscosity is less than six (6) stokes then the following procedure applies:Use the method given here as Figs. 1 and 2 to estimate Slip and calculate the required pump speed. Slip Correction for Viscosity n = np - [ (np - no) f ] or n = np - f.ns where n = corrected duty speed no = rpm at zero PSI for duty flow rate (from water performance curves) np = rpm at duty pressure for duty flow rate (from water performance curves (Fig 1)) np-no = Slip speed = ns From viscous slip curve (Fig 2) read slip factor f f x ns = slip speed correction = f.ns Corrected Speed for Duty n = np - f.ns
Example
176
PERFORMANCE CURVES BASED ON WATER AT 68F
CAPACITY (gpm)
132
0 PSI 58 PSI
88
44 no
np
100
200
300
400
500
SPEED RPM
Fig 1 Duty 88gpm, 58 PSI 100 centistokes (viscosity in pump) Corrected Duty Speed n = np - [ (np - no) f ] n = 410 - [ (410-300) x .78 ] = 324 rpm or n = np - f.ns n = 410 - 85.5 = 324 rpm
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Fig 2 Note: There is no slip correction necessary for water or product with a viscosity of one (1) centistoke.
EPSILON
1 2
Dec 2007
ALL CURRENT
6 When RPM is established identify: a) Maximum viscosity as indicated at the top of the performance curve labelled Viscosity Limits. Refer to page 3, Tolerance guidelines - Viscosity Limits. b) Abrasion capability as indicated at the top of the performance curve labelled Abrasion zone. Refer to page 3, Tolerance guidelines - Abrasion zone. If any of the parameters in steps 1 to 6 (b) do not meet the required criteria then re-select from (1) above with the next largest pump size. c) Rotor selection against temperature as indicated in the shaded area of the performance curve for the duty speed identified. Refer to Tolerance guidelines - Rotor selection. d) Absorbed power which is read on the y-axis (Absorbed power) at the differential pressure intersection point (BHP). If the product is viscous then note also the absorbed power on the zero pressure line (FHP) for use later in calculation. 7 If the pump meets the above criteria go to the PUMP CONFIRMATION SECTION. If no pump can be identified then please contact Monoflo for assistance. PUMP CONFIRMATION Having determined the pump size the following steps are necessary: 1 Read the NPSH required from the pump curve at the duty flowrate. Check that the N.P.S.H. required is less than N.P.S.H. available. 2 Note the starting torque required on the performance curve in the table labelled STARTING TORQUE against the selected rotor. 3 If the product is viscous obtain both Starting Torque (f T) and Power Additive (f FHP) factors from the Viscosity Curve graph read at the known viscosity in Stokes. 4 Confirm stator suitability for the product. (Refer to page 3, Tolerance guidelines - Stator selection) 5 Confirm material compatibility and availability for the pump chosen. 6 Select mechanical seal (standard) or packed gland as required. Information obtained from the DRIVE PUMP CONFIRMATION section will be used to determine the required drive. 1 If product is water like, then the absorbed power (BHP) will be as obtained in the PUMP SIZING section, step 6, item (d). Go to step 4. 2 Multiplying the pump starting torque by the starting torque factor obtained in the PUMP CONFIRMATION section, item 3 will give you the starting torque required for the given viscosity. (ie T(ft-lb) x fT = Starting torque at viscosity).(Refer to section DRIVE, items 5 and 6) 3 To obtain the power absorbed at the known viscosity then the full viscous calculation is: Viscous Brake Horsepower (V BHP) = Viscous frictional H.P. + W.H.P. a) Viscous Frictional Horsepower FHP x f FHP. FHP as identified in Pump Sizing section step 6, item (d) (zero PSI pressure). f FHP factor as identified in Pump Confirmation section step 3. Multiply FHP by correction factor f FHP to give frictional horsepower when handling the viscous product. b) Water Horsepower (WHP) is BHP - FHP BHP as identified in Pump Sizing section step 6, item (d) (at duty pressure). FHP as identified in Pump Sizing section step 6, item (d) (at zero PSI pressure). WHP is BHP - FHP c) Add viscous frictional horsepower to water horsepower to obtain BHP absorbed when handling a viscous product i.e. a + b.
4 Determine the motor input power required by allowing for the efficiency of the drive arrangement as follows: Efficiency % Drive Arrangement D.C. to a synchronous speed motor 100 D.C. to a fixed speed geared motor 92 D.C. to a variable speed geared motor 80 (D.C. = Direct Coupled) Therefore input power = BHP (or vBHP) divided by the efficiency.(ie. Input power required for a close coupled CB pump with a direct coupled fixed speed geared motor = BHP (or vBHP) / 0.92)
EPSILON
ALL CURRENT
1 3
Dec 2007
SELECTION PROCEDURE
5 Starting torque capabilities will be affected by the type of drive selected and method of starting. Generally motors wired for D.O.L. start on a 3 phase supply will provide 200% FLT (Full Load Torque). Motors wired for Star/Delta start on a 3 phase supply typically provide 50-70% FLT. Single phase motors (capacitor start) typically provide 200% FLT. In all cases reference should be made to the motor manufacturers performance tables. D.O.L. is the preferred method of starting a PC pump. 6 If starting is via an inverter type of drive then 125% FLT availability only is assumed. The correct matching of drive motor/inverter/pump is a specialised skill. Breakout torque and continuous slow running can cause problems. Always refer an inverter application to a specialist drive company, ensuring that they are aware of the full duty parameters to enable them to select the appropriate drive package. 7 Starting with a soft starter should be referred to the manufacturers specification, but typically starting torque will be 150% FLT. 8 Care should be taken when selecting other types of drives to ensure sufficient starting torque is available, i.e. single phase, hydraulic drives, air motors, engines etc. If in doubt refer to Monoflo. TOLERANCE GUIDELINES Rotor Selection Consider maximum fluid temperature, ambient temperature, operating speed and duration of running. All these factors affect stator temperature, in borderline cases select the higher temperature rotor. Fixed Speed If selection falls exactly between rotor types then select the higher temperature rotor. Variable Speed For variable speed drives select the rotor at maximum speed and maximum temperature. Mark 0 Rotors Mark 0 rotors are designed for use with water like liquids, i.e. less than 200 centistokes, or abrasive liquids. Use where either of the following details apply i) Pressure per stage is greater than two (29) PSI or ii) Suction required is greater then three (10) Feet H20 or iii) Medium/heavy abrasion type liquids. Mk 0 rotors must not be selected for use in conjunction with RH , R V & R J stators. Stator Selection Performance curves based on RR and RA stator materials. RR, RA, RH and RV are Mono stator material codes and are contained in the stator selection for each model. Please note that the following must be adhered to when selecting the stator grades: (RH) Refer to page 8 to identify starting torque and temperature rotor requirements.
(RV) Refer to page 9 for limitations on speed & pressure. The power absorbed must be increased by a factor of 1.2. Applications above 50oC (88oF) Should be refered back to Monoflo.
Published information other than that market certified is to be used as a guide only
PUMP MODEL
EPSILON
ALL
SECTION
1 4
PAGE
DATE
STATUS
CURRENT
Dec 2007
SELECTION PROCEDURE
Flow Rate The expected accuracy of progressing cavity pumps is 10% of pump maximum flowrate as shown by the Product Manual Curves. If specific duty points must be achieved ensure that Monoflo are aware of this. Viscosity limits The viscosity limits are shown in logarithmic scale and indicate maximum recommended viscosities in the pump for the speed selected. Abrasion zone The abrasion zone provides a guide to the pumps ability to handle abrasive products at different speeds with acceptable component life. Pressure has a proportional effect on wear therefore increasing the number of stages at constant pressure will significantly improve component life. NOTES PUMP ROTATION (DOG/SOG) The pump rotation is normally assumed anticlockwise (when looking on the pump drive shaft end) such that SOG (Suction-On-Gland) flow conditions prevail (ie, product enters at the suction chamber and leaves at the discharge chamber). PRESSURE LIMITATIONS The construction of each different range of pumps will result in maximum discharge pressures and maximum differential pressures that may differ depending upon the specific model, direction of rotation and port fittings. Please see Section 5. It is therefore important to check that both the differential pressure plus the inlet pressure do not exceed the maximum discharge pressure for the pump selected. TEMPERATURE LIMITATIONS Temperature limitations are dependant on material combinations used. If duty temperatures are outside the limits shown for a particular combination please contact Monoflo for guidance. SPEED LIMITATIONS If speeds below 50rpm are required then please contact Monoflo for assistance.
Published information other than that marked certified is to be used as a guide only
EPSILON
ALL
1 5 Dec 2007
CURRENT
MODEL MODEL SIZE SIZE 990.6 12K E1BK 726.4 550.3 427.0 347.8 E17K 250.9 E1AK E19K E18K
MODEL SIZE K BUILD 1849.2 E1E 1276.8 E1D 924.6 E1C 616.4 E1B 413.8 E1A 314.8 E19 253.1 E18 CAPACITY GPM 217.9 E17 156.3 E16 E15
112.2 E14K 63.4 E14 49.7 E1X 26.4 E13 E13K 14.9 E12 6.6 E11
44.0
0 0 58 87
0 0 87 174 348
DIFFERENTIAL PRESSURE-PSI
DIFFERENTIAL PRESSURE-PSI
Published information other than that marked certified is to be used as a guide only
1 6
May 2008
Standard Variation 12 13 14 15
Stages
A 1 E Epsilon Range 1 Design Mk 1 6 Size 06 A C Single Stage Cast Iron 8 Code 8 Rot Parts 1 Mk 1 Rotor R M A eMech ch Seal - St. Stl Flexi Seal - Std Build Option A Nitrile Stator
Published information other than that marked certified is to be used as a guide only
EPSILON
ALL CURRENT
1 7
Dec 2007
10000 1000
Viscosity in pump Stokes Starting Torque Power Additive
100
EPSILON
CURRENT
1 8
Dec 2007
NO SELECTION
MARK 5 ROTOR
% of rated speed
When selecting pumps fitted with RH stators please use the above rotor selection chart which indicates rotor type and recommended pump breakout torque multiplier for a given fluid temperature. The torque multiplier is required to allow for increased interference between rotor and stator. Notes 1 Mark zero rotors are not to be used with RH stators. 2 3 Rated speed is the maximum speed shown for each pump model as indicated on the appropriate performance curve. If the pump is to be operating for less than 15 minutes per hour then select the next larger rotor size (ie. if mark 5 rotor is initially selected then select mark 3).
Fluid temperature
EPSILON
1 9
ALL CURRENT
Dec 2007
SPEED / PRESSURE DERATE WHEN USING RV STATORS (UP TO 50oC) (880F) (Moulded to metal stators only)
100%
NOT SUITABLE
75%
Rated Speed
50%
25%
PUMP MODEL
EPSILON
ALL
SECTION
1 10
Dec 2007
PAGE
DATE
STATUS
CURRENT
CIP flow rates (hence pump speeds) should be maximised to achieve highest level of cleanability. Pumps fitted with CIP by pass ports will permit higher flow rates without the need to increase pump speed. The use of neat active caustic and acid chemicals is not recommended. Proprietary cleaning agents should be used in line with manufacturers instructions. Note A (C.I.P. process) i) ii) iii) iv) Pumps with Mark 1 Rotors must be limited to 50% of maximum pump speed. Pumps with Mark 3 and 5 Rotors do not have any limitation and can be cleaned as defined above. Pumps with Mark 0 Rotors: Please refer to Monoflo. For C.I.P. processes that differ to the one above please contact Monoflo for C.I.P. process confirmation.
Published information other than that marked certified is to be used as a guide only
EPSILON
E11B 6 174 1750 GPM PSI rpm
EPSILON
E11B
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 2 1
230 212
MARK 5 MARK 3 MARK 1 4 Pump Capacity (m/h) Pump Capacity (gpm) 1.0 MARK 0 PSI
0 87 130 174
140 104 68 32
0.5
Limit for water like products Capacities below this line require verification by Monoflo. 0 0
PSI
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.14
0.40
5.9
5.2
5.2
5.2
Published information other than that marked certified is to be used as a guide only
1.6
Temperature (F)
176
EPSILON
E11B CURRENT
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500 rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E11B CURRENT
FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Vertical
EPSILON
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
1.23 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 A SRF10/1/63
EPSILON
E11D 6 348 1750 GPM PSI rpm
EPSILON
E11D
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 2 1
230 212
1.5
MARK 5 MARK 3 MARK 1 PSI
0 174 261 348
140 104 68 32
MARK 0
0.5
Limit for water like products Capacities below this line require verification by Monoflo. 0
PSI
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 VISCOSITY IN PUMP (CENTISTOKES)
0.14
0.40
11.8
10.3
10.3
10.3
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
EPSILON
E11D CURRENT
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500 rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E11D CURRENT
FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Vertical
EPSILON
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
EPSILON
E12A 15 87.0 1750 GPM PSI rpm
EPSILON
E12A
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
3.5
MARK 5 PSI
0 29 43 58 87
13
3.0
MARK 0
MARK 3 MARK 1
140 104 68 32
2.0
1.0
0 1.0
Limit for water like products Capacities below this line require verification by Monoflo. 1.5
PSI
87 58 29 0
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.14
0.40
7.4
5.9
5.9
5.9
Published information other than that marked certified is to be used as a guide only
0.8
1.1
Temperature (F)
176
EPSILON
E12A CURRENT
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500 rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E12A CURRENT
FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Vertical
EPSILON
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
STATUS
EPSILON
E12B 15 174 1750 GPM PSI rpm
EPSILON
E12B
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
3.5
MARK 5 PSI
0 58 87 116 174
13
3.0
MARK 0
MARK 3 MARK 1
140 104 68 32
2.0
1.0
Limit for water like products Capacities below this line require verification by Monoflo.
0 1.6
116 87 58 0
PSI
1600
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.14
0.40
11.8
10.3
10.3
10.3
Published information other than that marked certified is to be used as a guide only
1.4
174
2.0 1.8
Temperature (F)
176
EPSILON
E12B CURRENT
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500 rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E12B CURRENT
FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Vertical
EPSILON
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Mechanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
EPSILON
E12D 15 348 1750 GPM PSI rpm
EPSILON
E12D
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1
Viscosity Limits (Stokes) 230 212
3.5
MARK 5 PSI
0 116 174 232 348
13
3.0
MARK 0
MARK 3 MARK 1
140 104 68 32
2.0
1.0
Limit for water like products Capacities below this line require verification by Monoflo.
0 3.2
PSI
400
600
1200
1400
1600
1800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.14
0.40
23.6
20.6
20.6
20.6
Published information other than that marked certified is to be used as a guide only
2.8
348
4.2 3.7
Temperature (F)
176
EPSILON
E12D CURRENT
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) Yes Max 1500 rpm Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E12D CURRENT
FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Vertical
EPSILON
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
EPSILON
E13A 25 87 1500 GPM PSI rpm
EPSILON
E13A
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212
6
MARK 5
PSI
0 29 58 87
22
5
MARK 0
MARK 3 MARK 1
140 104 68 32
17
13
1
Limit for water like products Capacities below this line require verification by Monoflo.
0 1.6
58 29 0
PSI
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.20
0.80
18.4
11.0
11.0
11.0
Published information other than that marked certified is to be used as a guide only
1.4
87
2.1 1.9
Temperature (F)
176
EPSILON
E13A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 03 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph
1000 100
10
1 0.1
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV Black
Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E13A CURRENT
GENERAL DATA
FITTINGS INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN
RANGE
NB (inch) -
Orientation Vertical
EPSILON
Can be rotated
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
RF40/1
GA
CHF032
GB
Published information other than that marked certified is to be used as a guide only
EPSILON
E13B 25 174 1500 GPM PSI rpm
EPSILON
E13B
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32
26
6 MARK 5
PSI
0 58 116 174
22
5 MARK 0
MARK 3 MARK 1
17
13
1 Limit for water like products Capacities below this line require verification by Monoflo.
3.0
4.0
116 58 0
PSI
1400
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.20
0.80
25.8
18.4
18.4
18.4
Published information other than that marked certified is to be used as a guide only
2.5
174
3.4
Temperature (F)
EPSILON
E13B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 03 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph
1000 100
10
1 0.1
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV Black
Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E13B CURRENT
GENERAL DATA
FITTINGS INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN
RANGE
NB (inch) -
Orientation Vertical
EPSILON
Can be rotated
COMMENTS
FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Can be rotated Standard 1 " B.S.P. Option 1 " N.P.T.
RANGE
NB (inch) -
Orientation Horizontal
EPSILON
COMMENTS
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
1.47 174 174 174 174 2.01 174 174 174 174 2.95 4.02 AVAILABLE SPEEDS rpm MOTOVARIO MONO REF. REF. RF50/1 GX HP 1.47 A 2.01 2.46 174 174 174 174 174
BUILD
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
Published information other than that marked certified is to be used as a guide only
EPSILON
E13D
CURRENT
MEDIUM 50 20
LIGHT 2
NIL
Abrasion Zones
0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32
6
MARK 5 PSI
0 116 232 348
22
5
MARK 0
MARK 3 MARK 1
18
13
1
Limit for water like products Capacities below this line require verification by Monoflo.
0
6.0
8.0
348 232 116 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.20
0.79
51.6
36.8
36.8
36.8
Published information other than that marked certified is to be used as a guide only
5.0
6.7
Temperature (F)
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 03403
E13D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON 2 2
SPECIFICATION
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
Vertical Vertical
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
OPTION ANSI B16.5 Class 300 RF JIS B2210 20 kgf ANSI B16.5 Class 300 RF JIS B2210 20 kgf
EPSILON
Horizontal Horizontal
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E041
45mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1XA 47 87 1500 GPM PSI rpm
EPSILON
E1XA
CURRENT
MEDIUM 10
LIGHT 2
12
MARK 3
44
MARK 1
35
MARK 0 68 32
26
17
Limit for water like products Capacities below this line require verification by Monoflo.
PSI 87 58 29 0
1200
1400
1600
1800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.24
0.94
17.7
13.3
13.3
13.3
Published information other than that marked certified is to be used as a guide only
Temperature (F)
10
EPSILON
E1XA CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes. Section 1 Yes RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV Black Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1XA CURRENT
2 0X103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 50 2 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
EPSILON
2 50
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
OPTION ANSI B16.5 Class 300 RF JIS B2210 20 kgf ANSI B16.5 Class 300 RF JIS B2210 20 kgf
2 50 2 50
Horizontal Horizontal
EPSILON
St. Steel COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL
RANGE
EPSILON
32mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
BUILD
Published information other than that marked certified is to be used as a guide only
EPSILON
E1XB 47 174 1500 GPM PSI rpm
EPSILON
E1XB
CURRENT
MEDIUM 50 20 10
LIGHT 2
Viscosity Limits (Stokes)
NIL
Abrasion Zones
100
0.01
230 212
MARK 5 44
10
PSI
0 58 116 174
MARK 3 MARK 1
MARK 0
35
26
17
0 6
Limit for water like products Capacities below this line require verification by Monoflo. 8.0
174 116 58 0
5 4 3 2 1 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.24
0.94
32.5
22.1
22.1
22.1
Published information other than that marked certified is to be used as a guide only
Temperature (F)
EPSILON
E1XB CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes. Section 1 Yes RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV Black Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1XB CURRENT
2 0X203
May 2008
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron 50 2.5 2.5 50 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
EPSILON
St. Steel
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 50 2 2 50 Horizontal Horizontal
OPTION ANSI B16.5 Class 300 RF JIS B2210 20 kgf ANSI B16.5 Class 300 RF JIS B2210 20 kgf
EPSILON
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL
RANGE
EPSILON
45mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 299 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 256 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
Published information other than that marked certified is to be used as a guide only
EPSILON
E1XD
CURRENT
MEDIUM 50 20 10
LIGHT 2
Viscosity Limits (Stokes)
NIL
Abrasion Zones
100
0.01
230 212 176 140 104 68 32
44
10
MARK 3 MARK 1
MARK 0
35
26
18
0 12
Limit for water like products Capacities below this line require verification by Monoflo. 12
348 232 116 0
10 8 6 4 2 0
10 8 6 4 2 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.23
0.94
64.9
44.3
44.3
44.3
Published information other than that marked certified is to be used as a guide only
Temperature (F)
MARK 5
PSI
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes. Section 1 Yes RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV Black Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 XD403
E1XD CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron 2.5 2.5 Vertical Vertical
OPTION ANSI B16.1 Class 125 FF JIS B2210 10 kgf ANSI B16.5 Class 150 FF JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 2 2 Horizontal Horizontal
OPTION ANSI B16.5 Class 300 RF JIS B2210 20 kgf ANSI B16.5 Class 300 RF JIS B2210 20 kgf
EPSILON
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E051
55mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E14A 64 87 1000 GPM PSI rpm
EPSILON
E14A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212
100
50
20
PSI
0 29 58 87
140 104 68 32
MARK 1 MARK 0
39.6
26.4
13.2
0 3
Limit for water like products Capacities below this line require verification by Monoflo. PSI
67
4.0
58 29
2.7
1
0
1.3
100
200
300
400
500
600
700
800
900
1000
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.24
0.87
36.88
22.1
22.1
22.1
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
EPSILON
E14A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 04 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH Black
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E14A CURRENT
2 04103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 2.5 65 2.5 65 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron 2.5 65 2.5 65 Horizontal Horizontal
STANDARD
OPTION
EPSILON
St. Steel COMMENTS
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 40 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E14A SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD B
272 308 343 381 419 459 500 542 52 58 65 72 80 87 87 95 87 103 87 MAXIMUM PRESSURE IN PSI
BUILD
129 162 179 197 215 234 254 274 295 316 410 491 24 31 34 37 41 45 87 87 48 87 87 52 87 87 56 87 87 60 87 87 78 87 87 95 87 87 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD
257 324 358 394 431 469 508 548 590 633 49 62 68 75 82 89 87 87 97 87 87 104 112 120 87 87 87 87 87 87 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 389 500 26 29 33 36 40 44 87 48 87 52 87 57 87 60 87 74 87 95 87 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 542 586 632 52 58 65 75 80 87 87 87 95 87 87 103 111 120 87 87 87 87 87 87 MAXIMUM PRESSURE IN PSI
SRF20/1/80
EPSILON
E14B 64 174 1000 GPM PSI rpm
EPSILON
E14B CURRENT PERFORMANCE DATA
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212
20
15
MARK 5 MARK 3 PSI
0 87 116 145 174
52
12
MARK 0
140 104 68 32
MARK 1
39
26
13
3
Limit for water like products Capacities below this line require verification by Monoflo. PSI
174 145 116 87 58 29 0
0 6
8.0
5.3
2.7
100
Rotor Selection
200
300
400
500
600
700
800
900
1000
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.24
0.87
66.4
36.8
36.8
36.8
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
Temperature (F)
176
EPSILON
2 04202
Dec 2007
E14B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 04 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RH Black Chlorosulphonated PE RJ Black High Nitrile RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E14B CURRENT
2 04203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 2.5 65 2.5 65 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 2.5 65 2.5 65 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E14B SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 174 174 174 174 350 174 174 174 174 380 174 174 174 174 411 174 174 174 174 443 174 174 174 174 545
BUILD
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD B
272 308 343 381 419 459 500 542 52 58 65 72 80 87 95 103 MAXIMUM PRESSURE IN PSI 159 159 145 145
BUILD
129 162 179 197 215 234 254 274 295 316 410 491 24 31 34 37 41 45 48 174 174 52 56 60 78 95 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
SRF10/1/63
BUILD
257 324 358 394 431 469 508 548 590 633 49 62 68 75 82 89 97 104 112 120 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 136 153 172 190 210 230 250 271 293 316 389 500 26 29 33 36 40 44 48 52 57 60 74 95 174 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174
SRF10/1/63
BUILD A
BUILD
272 308 343 381 419 459 500 542 586 632 52 58 65 72 80 87 95 103 111 120 174 174 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174
SRF20/1/80
EPSILON
E14D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2
Viscosity Limits (Stokes)
NIL 0.01
230 212 176 140 104 68 32
20
15
MARK 5 MARK 3 PSI
0 218 290 348
52
12
MARK 0
MARK 1
39
26
13
3
Limit for water like products Capacities below this line require verification by Monoflo. PSI
348 290 218 174 116 72 0
0 12
16 12 8 4 0
9 6 3 0
100
200
300
400
600
700
800
900
1000
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 20C using RR and RA stator materials.
0.31
1.18
110.6
73.8
73.8
73.8
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 04 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RH Black Chlorosulphonated PE RJ Black High Nitrile RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 04403
E14D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON 3 3
SPECIFICATION
STANDARD
OPTION
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
Horizontal Horizontal
EPSILON
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E061
45mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E15A 106 87 800 GPM PSI rpm
EPSILON
E15A
CURRENT
LIGHT 10 2 0.01
230
1000 110
500
100
50
Viscosity Limits (Stokes)
20
25
MARK 5 MARK 3 PSI
0 29 58 87
212
88
20
MARK 1
140 104 68 32
MARK 0
66
15
44
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo. PSI
87 58 29 0
5 4 3 2 1 0
100
Rotor Selection
200
300
400
Pump Speed (rpm)
500
600
700
800
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.40
1.38
62.7
36.7
36.7
36.7
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
EPSILON
E15A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 05 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH Black
Chlorosulphonated PE
RR Black Nitrile
RV Black
Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E15A CURRENT
2 05103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 3 80 3 80 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 3 80 3 80 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E15A SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 87 87 87 87 87 87 299 MAXIMUM PRESSURE IN PSI 72 72 72 72 72 72 72 72 72 72 256 MAXIMUM PRESSURE IN PSI 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 72 72 72 72
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD B
272 308 343 381 419 459 500 542 52 58 65 72 80 87 87 95 87 103 87 MAXIMUM PRESSURE IN PSI
BUILD
129 162 179 197 215 234 254 274 295 316 410 491 24 31 34 37 41 45 87 87 48 87 87 52 87 87 56 87 87 60 87 87 78 87 87 95 87 87 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD
257 324 358 394 431 469 508 548 590 633 49 62 68 75 82 89 87 87 97 87 87 104 112 120 87 87 87 87 87 87 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 389 500 26 29 33 36 40 44 87 48 87 52 87 57 87 60 87 74 87 95 87 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 542 586 632 52 58 65 72 80 87 87 87 95 87 87 103 111 120 87 87 87 87 87 87 MAXIMUM PRESSURE IN PSI
SRF20/1/80
EPSILON
E15B 101 174 800 GPM PSI rpm
EPSILON
E15B CURRENT PERFORMANCE DATA
HEAVY 1000 500 100
Viscosity Limits
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230
50
(Stokes)
20
110
25
MARK 5 MARK 3 PSI
0 87 130 174
212
88
20
MARK 1
140 104 68 32
MARK 0
44
66
15
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo.
0 10
PSI
174 145
13.4
6 4 2 0
116 87 58 29 0
100
200
300
400
500
600
700
800
0.28
1.06
118.0
73.8
73.8
73.8
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
10.7
Temperature (F)
176
EPSILON
E15B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 05 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E15B CURRENT
2 05203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 3 80 3 80 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICA TION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 80 3 3 80 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E15B SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
BUILD
103
136
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 159 159 159 159 159 159 159 302 159 159 159 159 159 159 159 329
145 145 145 145 145 356 145 145 145 145 145 384 414 444 576 690
276
MAXIMUM PRESSURE IN PSI 145 145 145 98 145 145 145 145 122 145 145 145 145 146 130 130 130 130 164 130 130 130 130 203 116 116 116 244
101 101
101 101
101 101
BUILD
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 241 174 174 174 174 174 174 174 174 174 267 174 174 174 174 174 174 174 174 174 294 174 174 174 174 174 174 174 322
174 174 174 174 174 174 380 411 443 545 700
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 159 159 159 159 159 159 159 159 159 159 159 145 145 145 145 145 130 130 130 130 130
174
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF10/1/63
BUILD A
BUILD
272 308 343 381 419 459 500 52 58 65 72 80 87 95 MAXIMUM PRESSURE IN PSI 174 159 159 145 174 159 159 145
SRF20/1/80
BUILD
154 172 210 230 250 271 293 316 389 500 29 33 40 44 48 52 57 60 74 95 174 174 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
SRF50/1/100
EPSILON
E15D
CURRENT
LIGHT 10 2 0.01
230 212 176 140 104 68 32
1000 110
500
100
50
Viscosity Limits (Stokes)
20
25
MARK 5 MARK 3 PSI
0 218 348
88
20
MARK 1
MARK 0
66
15
44
10
22
5
Limit for water like products Capacities below this line require verification by Monoflo. PSI
348 290 232 174 116 58 0
0 20
15 10 5 0
200
300
500
600
700
800
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.39
1.25
258
111
111
111
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 05 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 05403
E15D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 4 4 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
EPSILON
St. Steel
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E081
65mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E16A 154 87 700 GPM PSI rpm
EPSILON
E16A
CURRENT
MEDIUM
Abrasion Zones
LIGHT 10 2 0.01
230 212 176
20
40
MARK 3 MARK 1 MARK 0
154
35
PSI
0 29 58 87
140 104 68 32
132
30
110
25
88
20
66
15
44
10
22
0 8
Limit for water like products Capacities below this line require verification by Monoflo. 10.7
87 58 29
6 4 2 0
100
Rotor Selection
200
300
400
500
600
700
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.57
103.5
62.7
62.7
62.7
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
MARK 5
EPSILON
E16A CURRENT
10000
GENERAL DATA
POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 06 4 Pump N.P.S.H. Required Meters head of water
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 5C (41F) -5C (23F) -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No 5C (41F) 100C (212F) None No RA Black Natural RE Ethylene Propylene RH Black
Chlorosulphonated PE
RR Black Nitrile
RV Black
Fluoroelastomer
*RY/RK Urethane
70C (158F) 130C (266F) 110C (230F) None Yes None Yes Yes Section 1 No
Temperatures are for continuous operating conditions. Refer to Section 1 for derating. *Consult Monoflo for specific applications.
Published information other than that marked certified is to be used as a guide only
EPSILON
E16A CURRENT
2 06103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 100 4 4 100 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICA TION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 4 100 100 4 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E16A SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
BUILD
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 26 29 33 36 40 44 87 48 87 52 87 57 87 60 87 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 52 58 65 72 80 87 87 87 95 87 87 MAXIMUM PRESSURE IN PSI
SRF20/1/80
BUILD
154 172 210 230 250 271 293 316 389 500 29 33 40 44 48 52 87 87 57 87 87 60 87 87 74 87 87 95 87 87 MAXIMUM PRESSURE IN PSI
SRF50/1/100
EPSILON
E16B 154 174 700 GPM PSI rpm
EPSILON
E16B
CURRENT
LIGHT 10 2 0.01
230 212 176 PSI 0 131 140 104 68 32 Temperature (F)
20
176
40
154
35
MARK 0
MARK 1
132
30
110
25
174
88
20
66
15
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
22
0 15
10
13.4
58 29 0
6.7
0
0 100
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.41
184.4
110.7
110.7
110.7
Published information other than that marked certified is to be used as a guide only
EPSILON
E16B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 06 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH Black
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E16B CURRENT
2 06203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 4 100 100 4 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 100 4 100 4 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E16B SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 159 159 159 159 159 159 267 159 159 159 159 159 159 294 145 145 145 145 145 145 322 130 130 130 130 130 350
CHF052
GK
BUILD
191 HP 2.95 4.02 5.36 6.46 7.37 10.05 12.33 145 145 145
MAXIMUM PRESSURE IN PSI 145 145 145 145 145 145 145 145 145 145 130 130 130 130 130 120 130 130 130 130 130 149 130 130 130 130 130 130 165 130 130 130 130 130 130 189
RF80/1
GL
BUILD
86
95
MAXIMUM PRESSURE IN PSI USE GK 174 174 174 174 174 174 174 174 294 174 174 174 174 174 174 174 174 174 322 174 174 174 174 174 174 174 174 174 350 174 174 174 174 174 174 174 174 380
CHF062
GM
174 174
BUILD
191 HP 4.02 5.36 6.43 7.37 10.05 12.33 14.75 20.11 24.80 29.50
241
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159
USE GK,GL OR GM
RF100/1
GN
174
174
174 174
BUILD
391 HP 10.05 12.33 14.75 20.11 24.80 29.50 174 174 174 174 174 174
420
451
RF125/1
GQ
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
154 172 210 230 250 271 293 316 389 29 33 40 44 48 52 57 60 74 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174
SRF50/1/100
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 57 61 75 MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
EPSILON
E16D
CURRENT
LIGHT 10 2 0.01
230 212 176
1000 176
500
100
50
Viscosity Limits (Stokes)
20
40
MARK 3 MARK 1 MARK 0
MARK 5
154
35
PSI
0 218 348
140 104 68 32
132
30
110
25
88
20
66
15
44
10
22
0 30
Limit for water like products Capacities below this line require verification by Monoflo. 40.2
348
20
26.8
10
116 58 0
13.4
200
300
500
600
700
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.39
1.33
413
258
258
258
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 06 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 06403
E16D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICATION
STANDARD
OPTION
5 5
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 5 5 Horizontal Horizontal
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
EPSILON
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E101
85mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E17A 220 87 600 GPM PSI rpm
EPSILON
E17A CURRENT PERFORMANCE DATA
MEDIUM
Abrasion Zones
LIGHT 20 10 2 0.01
230
50
MARK 5 PSI
0 29 58 87
212
45 40 35
MARK 1
140 104 68 32
MARK 0
132 110 88 66 44 22 0
30 25 20 15 10 5 0 12
Limit for water like products Capacities below this line require verification by Monoflo. PSI
87
10 8 6 4 2 0
58 29 0
5.4 2.7 0
100
Rotor Selection
200
300
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
1.73
162.3
73.8
73.8
73.8
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
Temperature (F)
MARK 3
176
EPSILON
E17A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 07 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E17A CURRENT
2 07103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 5 125 5 125 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 5 125 125 5 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E17A SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 87 87 87 87 87 87 294 87 87 87 87 87 87 322 87 87 87 87 87 87 350 87 87 87 87 87 380 87 87 87 87 411 443 545
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF20/1/80
BUILD
154 172 210 230 250 271 293 316 389 29 33 40 44 48 52 87 87 57 87 87 60 87 87 74 87 87 MAXIMUM PRESSURE IN PSI
SRF50/1/100
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 87 87 87 57 87 87 87 61 87 87 87 75 87 87 87 MAXIMUM PRESSURE IN PSI
EPSILON
E17B 220 174 600 GPM PSI rpm
EPSILON
E17B
CURRENT
LIGHT 20 10 2 0.01
230
500
100
50
Viscosity Limits (Stokes)
50
MARK 5 PSI
0 87 145 174
212
40 35
MARK 1
140 104 68 32
MARK 0
132 110 88 66 44 22 0
30 25 20 15 10 5 0 20
Limit for water like products Capacities below this line require verification by Monoflo. PSI
174 145 116
15 10 5 0
87 58 29 0
100
Rotor Selection
200
300
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
1.73
332.0
184.4
184.4
184.4
Published information other than that marked certified is to be used as a guide only
Temperature (F)
45
MARK 3
176
EPSILON
2 07202
Dec 2007
E17B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 07 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH Black
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E17B CURRENT
2 07203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 5 125 5 125 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 5 125 5 125 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E17B SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
BUILD
CHF052
GK
BUILD
267 HP 5.36 6.43 7.37 10.05 12.33 101 101 101 101 69 HP 4.02 5.36 6.43 7.37 10.05 12.33 159 159 159 159
BUILD
87 87 87 120
87 87 87 149
87 87 165
72 72 189
72 236 261
MAXIMUM PRESSURE IN PSI 159 159 159 159 159 215 159 159 159 159 159 159 159 159 294 145 145 145 145 322 145 145 145 145 350
CHF062
GM
130 130
BUILD
191 HP 6.43 7.37 10.05 12.33 14.75 20.11 24.80 29.50 159 159 159 159
241
380
MAXIMUM PRESSURE IN PSI 159 159 159 159 159 159 159 159 159
RF100/1
GN
BUILD
72 HP 5.36 6.43 7.37 10.05 12.33 14.75 20.11 174 174 174 174 174 174 230 HP 10.05 12.33 14.75 20.11 24.80 29.50 174 174 174 174 174 174
94
104
127
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 255 174 174 174 174 174 174 174 280 174 174 174 174 174 174 306
CHF082
GP
BUILD
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
RF125/1
GQ
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
EPSILON
E17D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2 0.01
230 212 176 140 104 68 32
50
MARK 5 PSI
0 218 290 348
45 40 35
MARK 1
MARK 3
MARK 0
132 110 88 66 44 22 0
30 25 20 15 10 5 0
Limit for water like products Capacities below this line require verification by Monoflo. PSI
348 290 232 174 116 58 0
40 30 20 10 0
200
400
500
600
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 20C using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
1.68
553
369
369
369
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 07 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 07403
E17D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICA TION
STANDARD
OPTION
5 5
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
EPSILON
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E121
85mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E18A 255 87 500 GPM PSI rpm
EPSILON
E18A
CURRENT
LIGHT 20 10 2
230 212 176 0 29 58 140 104 68 87 32
1000 264
500
100
50
Viscosity Limits (Stokes)
60
PSI
50
MARK 1 MARK 0
132
176
40
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo. 16.1
87 58 29 0
0 12
10 8 6 4 2 0
100
Rotor Selection
200
300
Pump Speed (rpm)
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.63
2.09
184.4
132.8
132.8
132.8
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
EPSILON
E18A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 08 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
RV
Fluoroelastomer
Black
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E18A CURRENT
2 08103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 5 5 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 5 5 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 20 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E18A SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF50/1/100
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 87 87 87 57 87 87 87 61 87 87 87 75 87 87 87 MAXIMUM PRESSURE IN PSI
EPSILON
E18B 255 174 500 GPM PSI rpm
EPSILON
E18B
CURRENT
LIGHT 20 10 2
230 212 176 140 104 68 32
1000 264
60
500
100
50
Viscosity Limits (Stokes)
PSI
0 87 145 174
MARK 1 MARK 0
176
40
132
30
88
20
44
10
0 24
Limit for water like products Capacities below this line require verification by Monoflo. 32 26 21 16 10 5 0
20 16 12 8 4 0
100
Rotor Selection
200
300
Pump Speed (rpm)
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = n p - no, f x ns = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.47
1.69
368.8
276.6
276.6
276.6
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
EPSILON
E18B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 08 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 100C (212F) None No RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
*RY/RK Urethane
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating. *Consult Monoflo for specific applications.
Published information other than that marked certified is to be used as a guide only
EPSILON
E18B CURRENT
2 08203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 125 5 5 125 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICA TION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 125 5 5 125 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 20 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E18B SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
BUILD
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 174 174 174 174 174 174
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 57 61 75 MAXIMUM PRESSURE IN PSI 174 174 174 174
7.37 174 174 174 174 174 174 A SRF100/1/125 10.05 174 174 174 174 174 174 174 12.09 174 174 174 174 174 174 174
EPSILON
E18D
CURRENT
MEDIUM
Abrasion Zones
LIGHT 20 10 2
230 212 176 140 104 68 32
50
Viscosity Limits (Stokes)
60
MARK 5 MARK 3 PSI
0 174 261 348
220
50
MARK 0
MARK 1
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo. 67.0 53.6 40.2 26.8 13.4 0
0 50
40 30 20 10 0
300
400
500
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 bar/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 bar, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 20C using RR and RA stator materials.
0.51
1.73
738
443
443
443
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 08 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 3 4 5 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 100C (212F) None No RA Black Natural RE Ethylene Propylene RR Black Nitrile *RY/RK Urethane
Temperatures are for continuous operating conditions. Refer to Section 1 for derating. *Consult Monoflo for specific applications.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 08403
E18D CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICATION
STANDARD
OPTION
6 6
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
EPSILON
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 6 6 Horizontal Horizontal
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E121
85mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E19A 317 87 450 GPM PSI rpm
EPSILON
E19A
CURRENT
LIGHT 20 10 2
230 212 176 140 104 68 32
1000 352
80
500
100
Viscosity Limits (Stokes)
50
308
70
264
60
220
50
87
176
40
132
30
88
20
44
10
0 15
Limit for water like products Capacities below this line require verification by Monoflo. PSI
87
20.1
10
58 29 0
13.4
6.7
100
Rotor Selection
200
Pump Speed (rpm)
300
400
450
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 2 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials.
0.71
2.20
202.9
147.5
147.5
147.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
EPSILON
E19A CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 09 4
1000 100
3 10 2
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E19A CURRENT
2 09103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 150 6 150 6 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 6 150 6 150 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E19A SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 87 87 87 57 87 87 87 61 87 87 87 75 87 87 87 MAXIMUM PRESSURE IN PSI
EPSILON
E19B 317 174 450 GPM PSI rpm
EPSILON
E19B
CURRENT
HEAVY
Abrasion Zones
MEDIUM 100
Viscosity Limits (Stokes)
LIGHT 20 10 2
230 212
1000 352
500
50
80
MARK 5 MARK 3 MARK 1 MARK 0 PSI
0 87 130 174
308
70
264
60
220
50
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo. 37.5
174
0 28 24 20 16 12 8 4 0
43 0 87
PSI
100
200
300
400
450
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.71
2.20
405.7
368.8
368.8
368.8
Published information other than that marked certified is to be used as a guide only
Temperature (F)
EPSILON
E19B CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 09 4
1000 100
3 10 2
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E19B CURRENT
2 09203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 6 150 6 150 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 6 150 6 150 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E19B SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
MAXIMUM PRESSURE IN PSI 174 174 174 174 174 174 391 174 174 174 174 174 174 420 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
MAXIMUM PRESSURE IN PSI 116 116 116 116 116 116 116 116
Published information other than that marked certified is to be used as a guide only
BUILD
10.05 130 130 130 130 130 130 12.33 130 130 130 130 130 130
EPSILON
E1AA 423 87 400 GPM PSI rpm
EPSILON
E1AA
CURRENT
LIGHT 50 20 10 2
230 212 176 140 104 68 32
500
100
90
MARK 3
MARK 5
PSI
0
80 70
MARK 1
58 87
MARK 0
60 50 40 30 20 10 0 20
Limit for water like products Capacities below this line require verification by Monoflo. PSI
87 58
15 10
29
5 0
6.7 0
50
Rotor Selection
100
150
200
250
300
350
400
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.80
2.76
295.0
258.1
258.1
258.1
Published information other than that marked certified is to be used as a guide only
Temperature (F)
100
EPSILON
E1AA CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 10 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes Section 1 No RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile RV
Fluoroelastomer
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1AA CURRENT
2 10103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 150 6 6 150 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 150 6 6 150 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E1AA SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
EPSILON
2 10104
E1AA CURRENT
Dec 2007
191
215
241
294
322
350
380
RF100/1
GR
BUILD
72
94
104
127
158
175
189
236
260
87 87 87 87 87 87 87 87 87
87 87 87 87 87 87 87 87 87
87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
CHF082
GS
BUILD
169
199
220
87 87 87 87 87
87 87 87
87 87 87
24.80 29.50
BUILD
280
306
333
87 87 87 87 87
87 87 87 87 87
87 87 87 87 87 87 87 87 87
RF125/1
GU
Published information other than that marked certified is to be used as a guide only
2 10105
Dec 2007
BUILD
BUILD
164 182 200 219 238 279 300 322 31 35 38 42 45 53 87 87 87 87 87 87 87 57 61 MAXIMUM PRESSURE IN PSI
EPSILON
E1AB 422 174 400 GPM PSI rpm
EPSILON
E1AB
CURRENT
LIGHT 50 20 10 2
230
500
100
Viscosity Limits (Stokes)
90
MARK 3
MARK 5
212
PSI
0 130 174 176 140 104 68 32
80 70
MARK 1
MARK 0
60 50 40 30 20 10 0 40
Limit for water like products Capacities below this line require verification by Monoflo. PSI
174 145 116 87 58 29 0
30 20 10 0
0 50
Rotor Selection
MK0 ROTOR SELECTION SLIP CORRECTION TEST PARAMETERS
100
150
200
Pump Speed (rpm)
250
300
350
400
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.80
2.56
626.9
479.4
479.4
479.4
Published information other than that marked certified is to be used as a guide only
Temperature (F)
100
EPSILON
E1AB CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 10 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1AB CURRENT
2 10203
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 6 150 6 150 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 6 150 6 150 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E1AB SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
EPSILON
2 10204
E1AB CURRENT
Dec 2007
78
87
105
126
140
169
199
220
266
CHF102
GV
BUILD
280
306
333
RF125/1
GW
Published information other than that marked certified is to be used as a guide only
2 10205
Dec 2007
BUILD
EPSILON
E1AD
CURRENT
HEAVY 1000 500 MEDIUM
Abrasion Zones
50
20
10
2
230 212 176 140 104 68 32
90 80 70 MARK 0
MARK 3 MARK 1
PSI
0 261 348
60 50 40 30 20 10 0 Limit for water like products Capacities below this line require verification by Monoflo PSI
348 261 174 87 0
80 64 48 32 16 0
107 86 64 43 21 0
Temperature (F)
440
100
MARK 5
50 Rotor Selection
100
150
250
300
350
400
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
EPSILON
0.78
2.44
1253
958
958
958
Published information other than that marked certified is to be used as a guide only
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 10 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RJ Black High Nitrile RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating. Utilises 2 off E102 stators.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 10403
E1AD CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 8 200 8 200 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.5 Class 150 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 200 8 8 200 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.5 Class 300 BS EN 1092 Section 3.1 PN 40 JIS B2210 20 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300 JIS B2210 20 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E151
100mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1BA 660 87 350 GPM PSI rpm
EPSILON
E1BA
CURRENT
MEDIUM
Abrasion Zones
LIGHT 50 20 10 5
230 212 176 0 43 72 87 140 104 68 32
MARK 5
PSI
100 90 80 70 60 50 40 30 20 10 0 30
Limit for water like products Capacities below this line require verification by Monoflo. PSI
87
40.2
20
58 29 0
26.8
10
13.4
50
Rotor Selection
100
150
200
250
300
350
MK0 rotor is only to be used when viscosity is < 200cst and pressure is > 29 PSI/stage OR > 3m suction lift. n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.98
3.86
516.3
442.5
442.5
442.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
150
EPSILON
E1BA CURRENT
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 12 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RH
Chlorosulphonated PE
RR Black Nitrile
Black
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1BA CURRENT
2 12103
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 8 200 8 200 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 8 200 8 200 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEALING ARRANGEMENT PUMP SIZE E1BA SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
EPSILON
2 12104
E1BA CURRENT
Dec 2007
78
87
105
126
140
169
199
220
266
CHF102
GV
BUILD
280
306
72 72 72 72 72
58 58 58 58 58
58 58 58 58 58
RF125/1
GW
Published information other than that marked certified is to be used as a guide only
2 12105
Dec 2007
BUILD
EPSILON
E1BB
CURRENT
HEAVY 1000 660 616 572 528 484 150 140 130 120 110 MARK 0 500 100
Viscosity Limits (Stokes)
MEDIUM
Abrasion Zones
LIGHT 50 20 10 5
230 212 176 140 104 68 32
PSI
0 116 145 174
440
100 90 80 70 60 50 40 30 20 10 0 60 Limit for water like products Capacities below this line require verification by Monoflo PSI
174 145 116 87
80
40
54
20
58 29 0
27
50 Rotor Selection
100
150
200
250
300
350
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
EPSILON
0.98
2.95
1032
590
590
590
Published information other than that marked certified is to be used as a guide only
Temperature (F)
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE 12 4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
1000 100
10
1 0.1
0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RE Ethylene Propylene RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 12203
E1BB CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICATION
STANDARD
OPTION
8 8
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E151
100mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1BD
CURRENT
LIGHT 50 20 10 5
230
500
Viscosity Limits
100
(Stokes)
MARK 3
MARK 5
232 290
MARK 1 MARK 0
348
440
100
220
50
Limit for water like products Capacities below this line require verification by Monoflo
100 80 60 40 20 0
134 107 80 53 26 0
PSI
0
100
300
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
EPSILON
0.98
2.95
2065
1180
1180
1180
Published information other than that marked certified is to be used as a guide only
0 120
160
Temperature (F)
PSI
212
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RR Black Nitrile
Temperatures are for continuous operating conditions. Utilises 2 off E122 stators. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 12403
E1BD CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS 8 8 Vertical Vertical OPTION Can be rotated Can be rotated STANDARD
SPECIFICATION
OPTION
EPSILON
BS EN 1092 Section 3.1 PN 16 ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 8 8 Horizontal Horizontal
STANDARD
OPTION
EPSILON
BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300 BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E201
140/160*
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details. 140 for MS. 160 for PG*
Published information other than that marked certified is to be used as a guide only
EPSILON
E1CA
CURRENT
MEDIUM
Abrasion Zones
LIGHT 50 20 10
230
PSI
29 58 87
Limit for water like products Capacities below this line require verification by Monoflo 67
87 58 29 0
40 30 20 10 0
53 40 26 13 0
50 Rotor Selection
100
200
250
270
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
EPSILON
1.18
4.13
885
663
663
663
Published information other than that marked certified is to be used as a guide only
PSI
Temperature (F)
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 1 on how to use this graph
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes. Section 1 No RR Black Nitrile RV Black Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 15103
E1CA CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICATION
STANDARD
OPTION
10 10
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel 10 10 Horizontal Horizontal
STANDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E151
100mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1CB
CURRENT
HEAVY 1000 990 880 770 660 225 MARK 3 200 MARK 0 175 150 MARK 1 500 100
Viscosity Limits
MEDIUM
Abrasion Zones
LIGHT 50 20 10
230 212 140 104 68 32
(Stokes)
MARK 5
0 58 87 174
125 100 75 50 25 0 100 Limit for water like products Capacities below this line require verification by Monoflo PRESSURE LIMITATION SEE SECTION 1
134
60 40 20 0
174
116
80
87 58 0
53 26 0
PSI
50
100
200
250
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
EPSILON
1.18
4.72
1770
1327
1327
1327
Published information other than that marked certified is to be used as a guide only
80
107
Temperature (F)
PSI
176
GENERAL DATA
10000 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE
1000 100
10
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes RA Black Natural RR Black Nitrile
Temperatures are for continuous operating conditions. 2 single stage E151 stators used in pump build. Refer to Section 1 for derating.
Published information other than that marked certified is to be used as a guide only
EPSILON
2 15203
E1CB CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON 12 12
SPECIFICATION
STANDARD
OPTION
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
STANDARD
OPTION
EPSILON
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E201
140/160*
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details. 140 for MS. 160 for PG.*
Published information other than that marked certified is to be used as a guide only
EPSILON
E1DA
CURRENT
HEAVY 1000 1320 1188 1056 924 300 270 MARK 1 240 210 MARK 0 MARK 3 500
MEDIUM
Abrasion Zones
LIGHT 50 20
230 212 176 140 104 68 32 87
100
Viscosity Limits (Stokes)
50 PSI
0 29 58
Limit for water like products Capacities below this line require verification by Monoflo 80 67
87 58 29 0
50 40 30 20 10 0
53 40 26 13 0
PSI
50 Pressure Limitation
100
200
250
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
EPSILON
1.18
4.13
958
737
737
737
Published information other than that marked certified is to be used as a guide only
Temperature (F)
PSI
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 1 on how to use this graph
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -5C (23F) 110C (230F) None Yes Temperatures are for continuous operating conditions. Refer to Section 1 for derating. RR Black Nitrile
Published information other than that marked certified is to be used as a guide only
EPSILON
2 16103
E1DA CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron
EPSILON
SPECIFICATION
STANDARD
OPTION
10 10
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
STA NDARD
OPTION
EPSILON
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E151
100mm
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1EA
CURRENT
50
20
230
Viscosity Limits
(Stokes)
450 MARK 3 400 350 300 250 200 150 100 50 0 100 80 60 40 20 0
87 58 29 0
MARK 5
PSI
0 29
MARK 1 MARK 0
58 87
Limit for water like products Capacities below this line require verification by Monoflo 134 107 80 53 26 0
PSI
50
150
200
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 1 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
EPSILON
1.37
4.13
1475
1106
1106
1106
Published information other than that marked certified is to be used as a guide only
Temperature (F)
212
4 Pump N.P.S.H. Required Meters head of water Refer to Section 1 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
10 1 0.1 0.01
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS -5C (23F) 110C (230F) None Yes Temperatures are for continuous operating conditions. Refer to Section 1 for derating. RR Black Nitrile
Published information other than that marked certified is to be used as a guide only
EPSILON
2 20103
E1EA CURRENT
Dec 2007
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY NB ORIENTATION MATERIAL (inch) Cast Iron St. Steel COMMENTS
12 12
SPECIFICATION
STANDARD
OPTION
EPSILON
Vertical Vertical
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
STANDARD
OPTION
EPSILON
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data
SEAL BODY SIZE Shaft For Seal (mm) Standard MS Single DIN 24960 PG CI Pump Graphited Acrylic/ Glass Yarn Option PG SS Pump Lubricated Aramid Yarn
E201
140/160*
COMMENTS
- Diameter. CI - Cast Iron. SS - Stainless Steel. MS - Machanical Seal. PG - Packed Gland. Refer to Section 5 for further details. 140 for MS. 160 for PG.*
Published information other than that marked certified is to be used as a guide only
EPSILON
E13K 44 87 1500 GPM PSI rpm
EPSILON
E13K
CURRENT
MEDIUM 20 10
LIGHT
Abrasion Zones
NIL 1 0.01
Viscosity Limits (Stokes) 230 212 176 140 104 68 32 Temperature (F)
10 9 8 7 Pump Capacity (m/h) 6 5 4 3 2 1 0 2.4 Absorbed Power (kW) 1.8 1.2 0.6 0
Limit for water like products Capacities below this line require verification by Monoflo. CONSULT MONOFLO
PSI
0 44
MARK 1
87
3.2
87 58 44 29 15 0
PSI
200
400
600
800
1000
1200
1400
1600
1800
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR stator material.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.20
0.80
11.80
Published information other than that marked certified is to be used as a guide only
73
EPSILON
E13K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 7 6 Pump N.P.S.H. Required Meters head of water 5 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7 0 8 17 26 35 Pump Capacity (GPM) 44 PUMP N.P.S.H(R) CURVE SIZE 3K
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Ye s -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E13K
CURRENT
GENERAL DATA
FITTINGS BODY MATERIAL Cast Iron St. Steel COMMENTS NB (inch) INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal NB Nominal Bore OPTION Can be rotated STANDARD 1 B.S.P. SPECIFICATION OPTION 1 N.P.T.
COMMENTS
SEALING ARRANGEMENT PUMP SIZE E 13K SHAFT DIAMETER 32mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 5 rings, 8 square
Published information other than that marked certified is to be used as a guide only
BUILD
443 545
2.01 2.46
Published information other than that marked certified is to be used as a guide only
BUILD
158 200 235 254 275 296 317 394 411 468 508 548 633 823 980 30 38 45 48 52 56 87 60 87 75 87 87 87 78 87 87 87 89 87 87 87 96 87 87 87 104 120 156 186 87 87 87 87 87 87 87 87 87 87 87 87 MAXIMUM PRESSURE IN PSI
BUILD
136 154 172 210 230 271 293 339 415 530 829 26 29 33 40 44 52 87 87 56 87 87 65 87 87 79 87 87 101 158 87 87 87 87 MAXIMUM PRESSURE IN PSI
BUILD
BUILD
210 230 271 293 339 415 530 829 40 44 52 56 65 79 87 87 101 158 87 87 87 87 MAXIMUM PRESSURE IN PSI
SF10C-RF40/1
BUILD
308 344 419 459 542 586 679 830 58 65 80 87 103 111 129 158 MAXIMUM PRESSURE IN PSI 87 87 87 87 87 87
SF10C-RF40/1
(2 pole motors)
EPSILON
E14K 97 58 800 GPM PSI rpm
EPSILON
E14K
3
E14K01 Dec 2007
CURRENT
LIGHT 1 0.01
230 212 176 140 104 68 32
22
CONSULT MONOFLO
MARK 1
61 52 44 35 26 17 8 0
6.7
58 43 29 14 0 PSI
400
Pump Speed (rpm)
600
800
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.24
0.87
36.9
Published information other than that marked certified is to be used as a guide only
EPSILON
E14K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5
PUMP N.P.S.H(R) CURVE SIZE 4K
4
Pump N.P.S.H. Required Meters head of water
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph
0 0
Pump Capacity (GPM)
26
52
79
96
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Ye s -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E14K
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 2.5 2.5 2.5 65 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 2.5 65 2.5 65
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION 90? end cover Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 14K SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
191
215
241
267
294
322
350
380
411
443
545
700
58 58 58 58 58
58 58 58 58 58 58
58 58 58 58 58 58 58 158
58 58 58 58 58 58 58 180 58 58 58 58 58 58 299
MAXIMUM PRESSURE IN PSI
58 58 58 58 58 58
58 58 58 58 58 58
58 58 58 58 58 58
58 58 58 58 58
58 58 58 58 58
58 58 58 58 58 58 58 58 58
102
119
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58 58 195
58 58 58 58 58 58 58 58 58 58 256
MAXIMUM PRESSURE IN PSI
103
136
157
58 58
276
302
58 58 58 241
58 58 58 58 267
58 58 58 58 294
58 58 58 58 322
58 58 58 58 350
58 58 58 58 380
58 58 58 58 411
58 58 58 58 443
58 58 58 545
MONO REF.
GH
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD B
272 308 343 381 419 459 500 542 52 58 65 72 80 87 58 95 58 103 58 MAXIMUM PRESSURE IN PSI
BUILD
129 162 179 197 215 234 254 274 295 316 410 491 24 31 34 37 41 45 58 58 48 58 58 52 58 58 56 58 58 60 58 58 78 58 58 95 58 58 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD
257 324 358 394 431 469 508 548 590 633 49 62 68 75 82 89 58 58 97 58 58 104 112 120 58 58 58 58 58 58 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 389 500 26 29 33 36 40 58 44 58 48 58 52 58 57 58 60 58 74 58 95 58 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 542 586 632 52 58 65 72 80 87 58 58 95 58 58 103 111 120 58 58 58 58 58 58 MAXIMUM PRESSURE IN PSI
SRF20/1/80
EPSILON
E15K 162 58 700 GPM PSI rpm
EPSILON
E15K
3
E15K01 Dec 2007
CURRENT
LIGHT 1 0.01
230 212
40
CONSULT MONOFLO
PSI 0 43 58
154
35
MARK 1
110
25
88
20
66
15
44
10
22
Limit for water like products Capacities below this line require verification by Monoflo.
200
300
400
500
600
700
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.40
1.38
88.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
EPSILON
E15K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 4.6 4 Pump N.P.S.H. Required Meters head of water PUMP N.P.S.H(R) CURVE SIZE 5K
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E15K
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 3 80 3 80 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION 90? end cover Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 15K SHAFT DIAMETER 45mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD B
272 308 343 381 419 459 500 542 52 58 65 72 80 87 58 95 58 103 58 MAXIMUM PRESSURE IN PSI
BUILD
129 162 179 197 215 234 254 274 295 316 410 491 24 31 34 37 41 45 58 58 48 58 58 52 58 58 56 58 58 60 58 58 78 58 58 95 58 58 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD
257 324 358 394 431 469 508 548 590 633 49 62 68 75 82 89 58 58 97 58 58 104 112 120 58 58 58 58 58 58 MAXIMUM PRESSURE IN PSI
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 389 500 26 29 33 36 40 44 58 48 58 52 58 57 58 60 58 74 58 95 58 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 542 586 632 52 58 65 72 80 87 58 58 95 58 58 103 111 120 58 58 58 58 58 58 MAXIMUM PRESSURE IN PSI
SRF20/1/80
EPSILON
E16K 250 58 600 GPM PSI rpm
EPSILON
E16K
3
E16K01 Dec 2007
CURRENT
LIGHT 1 0.01
230 212
CONSULT MONOFLO
220
50
MARK 1
0 43 58
140 104 68 32
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
100
Rotor Selection
200
400
500
600
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.57
147.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
PSI
176
EPSILON
E16K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 5 Pump N.P.S.H. Required Meters head of water 4 3 2 1 0 0 44 88 132 176 220 250 PUMP N.P.S.H(R) CURVE SIZE 6K
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Ye s -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E16K
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 4 100 4 100 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 4 100 4 100
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION 90? end cover Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 16K SHAFT DIAMETER 55mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 10 square
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF10/1/63
BUILD A
136 153 172 190 210 230 250 271 293 316 26 29 33 36 40 44 58 48 58 52 58 57 58 60 58 MAXIMUM PRESSURE IN PSI
BUILD
272 308 343 381 419 459 500 52 58 65 72 80 87 58 58 95 58 58 MAXIMUM PRESSURE IN PSI
SRF20/1/80
BUILD
154 172 210 230 250 271 293 316 389 500 29 33 40 44 48 52 58 58 57 58 58 60 58 58 74 58 58 95 58 58 MAXIMUM PRESSURE IN PSI
SRF50/1/100
EPSILON
E17K 348 58 500 GPM PSI rpm
EPSILON E17K
3
E17K01 Dec 2007
CURRENT
LIGHT 1 0.01
230 212 PSI 176 140 104 68 32
Temperature (F)
60
0 43 58
220
50
176
40
132
30
88
20
44
10
Limit for water like products Capacities below this line require verification by Monoflo.
0 20
Absorbed Power (KW)
16 12 8 4 0 200
Pump Speed (rpm)
58 43 29 14 0
300
400
500
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
1.73
184.4
Published information other than that marked certified is to be used as a guide only
PSI
EPSILON
E17K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 5 Pump N.P.S.H. Required Meters head of water 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7
0 44 88 132 176 220 264 308 347
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Ye s -5C (23F) 110C (230F) None Yes RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E17K
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 5 125 5 125 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 5 125 125 5
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 17K SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
70
84
98
122
146
164
203
245
58 58 58 58
58 58 58 58 58
267
294
322
350
58 58 58 58 69
58 58 58
191
215
241
294
322
58
58
58 58
72
94
104
127
158
175
58 58 58
58 58 58 58
255
280
RF125/1
GQ
24.80 29.50
58
58 58
58 58
58 58 58
58 58 58
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
SRF50/1/100
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 58 58 58 57 58 58 58 61 58 58 58 75 58 58 58 MAXIMUM PRESSURE IN PSI
EPSILON
E18K 427 58 450 GPM PSI rpm
EPSILON
E18K
3
E18K01 Dec 2007
CURRENT
HEAVY 500 440 396 352 308 Pump Capacity (GPM) 264 220 176 132 88 44 0 Pump Capacity (m3/h) 100 100 50
LIGHT 1 0.01
230 212 176 140 104 68 32 Temperature (F)
CONSULT MONOFLO 90
MARK 1
PSI 0 43 58
10
13.4
14 0
6.7
0 0 100
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.63
2.09
295.0
Published information other than that marked certified is to be used as a guide only
EPSILON
E18K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6.5 6 5 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7
0 44 88 132 176 220 264 308 352 396 440
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E18K
SECTION PAGE
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 5 125 5 125 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 125 5 125 5
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 18K SHAFT DIAMETER 65mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
70
84
98
122
146
164
203
245
58 58 58 58
58 58 58 58 58
CHF052
GK
267
294
322
350
58 58 58 58
69
86
95
58 58 58
191
215
58
58
58 58
72
94
104
127
158
175
58 58 58
58 58 58 58
280
306
RF125/1
GQ
24.80 29.50
58 58
58 58
58 58 58 58 58
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
164 182 200 219 238 279 300 322 393 31 35 38 42 45 53 58 58 58 57 58 58 58 61 58 58 58 75 58 58 58 MAXIMUM PRESSURE IN PSI
EPSILON
E19K 550 58 400 GPM PSI rpm
EPSILON
E19K
3
E19K01 Dec 2007
CURRENT
LIGHT 1 0.01
230 212 Temperature (F) PSI 0 58 176 140 104 68 32
80 70 60 50 40 30 20 10 0 30
PSI
Limit for water like products Capacities below this line require verification by Monoflo.
40.2
Absorbed Power (HP)
20
58 43 29 14 0
26.8
10
13.4
0 0
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
0 100 200
Pump Speed (rpm)
300
400
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.71
2.20
331.9
Published information other than that marked certified is to be used as a guide only
EPSILON
E19K
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Meters head of water
6
10 1 0.1 0.01 1 2 4 5 3 Correction Factor 6 7 Refer to Section 2 on how to use this graph
0
0 88
176
264
352
440
528
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS -10C (14F) 70C (158F) None Yes 5C (41F) 130C (266F) None Ye s -5C (23F) 110C (230F) None Ye s RA Natural Rubber Black RE Ethylene Propylene Black RR Nitrile Rubber Black
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E19K
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 6 150 6 150 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 6 150 6 150
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 SPECIFICATION OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E 19K SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
Published information other than that marked certified is to be used as a guide only
BUILD
BUILD
164 182 200 219 238 279 300 322 31 35 38 42 45 53 58 58 58 58 58 58 58 57 61 MAXIMUM PRESSURE IN PSI
EPSILON
E1AK 726 58 350 GPM PSI rpm
EPSILON
E1AK
CURRENT
HEAVY 500 Viscosity Limits (Stokes) 792 704 616 528 440 180 100
LIGHT 10 2 1 0.01
230 212 176 PSI 140 104 68 32 Temperature (F)
20
CONSULT MONOFLO
0 43 58
352 264
80 60
40 20 0 30
PSI 58 Limit for water like products Capacities below this line require verification by Monoflo.
20
43 29
26.8
10
14 0
13.4
0 0 50
Rotor Selection
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.80
2.76
442.5
Published information other than that marked certified is to be used as a guide only
EPSILON
E1AK
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 6 5 Pump N.P.S.H. Required Meters head of water 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7
0 88
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1AK
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 6 6 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E1AK SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 12.5 square
Published information other than that marked certified is to be used as a guide only
EPSILON
3 E1AK04
E1AK CURRENT
Dec 2007
191
215
241
294
322
350
58 58
58 58
58 58 58
58 58 58 58
58 58 58 58 58
58 58 58 58 58 58
RF100/1
GR
72
94
104
127
158
175
189
236
260
58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58
CHF082
GS
126
140
169
199
220
266
CHF102
GT
24.80 29.50
58 58
58 58
58 58
58 58
58 58 58
BUILD
280
306
333
MAXIMUM PRESSURE IN PSI
24.80
58 58 58
58 58 58 58 58
RF125/1
GU
29.50 40.23
Published information other than that marked certified is to be used as a guide only
3 E1AK05
Dec 2007
BUILD
BUILD
164 182 200 219 238 279 300 322 31 35 38 42 45 53 58 58 58 58 58 58 58 57 61 MAXIMUM PRESSURE IN PSI
EPSILON
E1BK 991 58 270 GPM PSI rpm
EPSILON
E1BK
CURRENT
1
230 212 176
140 104 68 32
Limit for water like products Capacities below this line require verification by Monoflo.
PSI 58 43 29 14 0
100
200
250
270
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F using RR and RA stator materials.
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.98
3.86
590.0
Published information other than that marked certified is to be used as a guide only
EPSILON
E1BK
CURRENT
GENERAL DATA
10000 1000 100 VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 5 PUMP N.P.S.H(R) CURVE SIZE BK 4 Pump N.P.S.H. Required Meters head of water Refer to Section 2 on how to use this graph 1 2 4 5 3 Correction Factor 6 7
10 1 0.1 0.01
0
0 176
352
528
704
800 990
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft - Standard Flexishaft - Short Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated UM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE
Material Code Material Description Colour Temperature Minimum Maximum Performance De-rating Food Approved COMMENTS
Specified temperatures are for continuous conditions. Refer to Section 1 for de-rating guidelines.
Published information other than that marked certified is to be used as a guide only
EPSILON
E1BK
CURRENT
GENERAL DATA
FLANGE / FITTINGS BODY MATERIAL Cast Iron St. Steel NB (inch) 8 8 INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN ORIENTATION Vertical Vertical OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN ORIENTATION Horizontal Horizontal OPTION Can be rotated Can be rotated STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16
SPECIFICATION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf Japanese Sewage Spec. ANSI B16.5 Class 150 JIS B2210 10 kgf
COMMENTS
NB Nominal Bore. This may vary depending on flange specification. Refer to Section 5 for full flange data.
SEALING ARRANGEMENT PUMP SIZE E1BK SHAFT DIAMETER 85mm STANDARD MECHANICAL SEAL Single DIN 24960 OPTIONAL PACKED GLAND 6 rings, 15 square
Published information other than that marked certified is to be used as a guide only
EPSILON
3 E1BK04
E1BK CURRENT
Dec 2007
54
65
78
87
105
126
140
169
199
220
266
58 58 58 58 58 58
58 58 58 58 58 58 58
58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
58 58 58 58 58 58 58 58
CHF102
GV
Published information other than that marked certified is to be used as a guide only
3 E1BK05
Dec 2007
BUILD
SECTION 4
EPSILON
ALL CURRENT
4 1
Dec 2007
When ordering parts you will need to have the following information ready. 1. The full parts code e.g. BD C041 2525. If the parts cannot be identified or the full parts code is unknown then other information will be needed. 2. 3. 4. 5. NOTE The pump type and order number have been inserted on the facsimile nameplate, this nameplate is fixed onto the pump in a prominent position. The actual certified pump parts list was also enclosed within the O&M instructions. This should be used in conjunction with the exploded views when ordering new parts. The pump type E14AC11RMA. The part description Rotor/Stator/Shaft etc. The material required or the rotating parts code. The pump serial number.
Published information other than that marked certified is to be used as a guide only
4 2 Dec 2007
MATERIALS PARTS IDENTIFICATION The items to be ordered can be identified in several ways. Many rotating parts will carry their parts number etched on them. The exact part number for the component used in your pump can be identified from the parts listing, which can be found inside the Operating and Maintenance Instructions booklet which accompanied your pump. An example of which is at the back of this section. If you do not know the description of your part, this again can be found using the Operating and Maintenance Instructions or the relevant section from this manual. For this you would need the typical pump drawing and the drawing reference number page. It is also possible to identify the part if you have the full pump code. Refer to the pump coding information in the relevant section in this manual. An example of how this can be done now follows. Firstly lets look at how the pump coding is drawn up. Example of Epsilon Range Coding Sheet follows on next page.
Published information other than that marked certified is to be used as a guide only
4 3
Dec 2007
Standard Variation 12 13 14 15
Stages
A 1 E Epsilon Range 1 Design Mk 1 6 Size 06 A C Single Stage Cast Iron 8 Code 8 Rot Parts 1 Mk 1 Rotor R M A ech Seal Mech Seal -- St. St. Stl Stl Flexi Build Option A Nitrile Stator
Published information other than that marked certified is to be used as a guide only
4 4 Dec 2007
The maximum number of characters in any pump coding can be fifteen. The following pump characters can be described within these limits. PUMP RANGE DESIGNATION Represents the range description. PUMP MARK NO. As modifications are made to the pump design so the mark number will be up stroked. PUMP CAPACITY OR SIZE Represents the pump size with the specified range. NO. OF STAGES Represents the number of complete stages within the rotor/stator element and would be indicated as A for single stage, B for two stage, D for four stage and K for single stage, extended pitch. PUMP BODY MATERIAL General material description of pressure boundary items i.e. suction and delivery parts. ROTATING PARTS CODE Identifies the material combination code for the main rotating parts in contact with the fluid being pumped. ROTOR MARK NO. Identifies standard or temperature variant rotor. STATOR MATERIAL Identifies the stator material by using the second letter of any standard resilient stator material code i.e. A for RA. SEALING ARRANGEMENT / FLEXISHAFT MATERIAL Identifies mechanical seal or packed gland & stainless steel or titanium flexishaft. BUILD OPTION Identifies drive interface to suit drive type required. OBLIQUE SYMBOL(/) The oblique symbol separates the basic pump code from the standard variation code.
Published information other than that marked certified is to be used as a guide only
EPSILON
ALL CURRENT
4 5
Dec 2007
THE STANDARD VARIATION CODE The standard variation code identifies one or more design features that are different from the standard pump build. This code is used to specify features that will be built into the pump to satisfy the customer specification. Each pump coding system is designed to suit the characters for each range and inevitable there is limited consistency across the range of pump systems. The example pump code we will be looking at is E14AC11RM A. The First Position E = Endurance Range. The Second Position 1 = Design Mark 1. Third and Fourth 4A = The pump size and no. of stages in this case size four single stage. Fifth Position C = Material of construction - in this case cast iron. The Sixth Position 1 = The rotating parts code in this case code 1. With this number we are able to specify the correct parts number for all rotating parts.
On the following pages there is an example of the rotating parts code page from section 2. We have been given a rotating parts code of 1 from the pump coding. Refering to the table you will see that this is for medium abrasive and non-corrosive products. Looking down you will see that the shaft would be made from SX (Stainless Steel) and the rotor is made from BD (Alloy Steel) and is HCP (Hard Chrome Plated), this procedure continues for the remaining items. Referring to the parts listed on page 8 these two parts would be SX C041 3250 and BD C041 2525. If there are still problems with parts identification or parts ordering, contact Monof l o and ask for the Sales Office Spares.
Published information other than that marked certified is to be used as a guide only
4 6 Dec 2007
Seventh Position 1 = The rotor mark number in this case mark 1. Eighth Position R = The stator material in this case RR (Nitrile Rubber). Ninth Position M = Seal type in this case mechanical seal and stainless steel flexishaft. Tenth Position A = Build option. This identifies the drive interface with regard to shaft diameter, flange sizes etc.
Published information other than that marked certified is to be used as a guide only
EPSILON
4 7
Dec 2007
ALL CURRENT
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP UM Halar Coated SX SX HCP 1 Light Corrosive SF UM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP UM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
ROTATING PARTS CODE GUIDE Code Abrasion Corrosion Rotor Flexishaft Shaft - Mech Seal Shaft - Packed Seal Medium Non - corrosive BD HCP SM Halar Coated SX SX HCP 1 Light Corrosive SF SM Halar Coated SF SF HCP 5 Medium Corrosive SF HCP SM Halar Coated SF SF HCP 8
Comments
BD - Alloy Steel. SF/SX - Stainless Steel. UM - Titanium. HCP - Hard Chrome Plate. If alternative materials are required please refer to Monoflo. Corrosion: Check suitability of materials for corrosion resistance.
Published information other than that marked certified is to be used as a guide only
EPSILON
ALL CURRENT
4 8
Dec 2007
CARBON STL. TAPER PLUG 1/4 NPT ST.STL. TAPER PLUG 1/8 NPT TORL SEAL RING 0425 - 30 BK NITR TORL SEAL RING 0425 - 30 BK NITR TORL SEAL RING 0166 - 24 BK NITR TORL SEAL RING 0166 - 24 BK NITR MAL IRON TAPER PLUG 1/2BSP MAL IRON TAPER PLUG 1/2BSP SNGL. COIL SPR WASHER M8 STEEL HEX. NUT M8 STEEL BRIGHT WASHER M8 SIGL . COIL SPR WASHER M8 TORL SEAL RING 0895 - 30 BK NITR TORL SEAL RING 0895 - 30 BK NITR TORL SEAL RING 0895 - 30 BK NITR DO NOT RE ORDER ST.STL SOC HD CAPSCREW M4 X 30 MAL IRON TAPER PLUG 1/2BSP BODY-STD C.I. NP E RANGE SOG PACK SIZE = 100 NP E RANGE SOG PACK SIZE = 100 M / SEAL 45mm DIN24960 - Sic / Sic THROWER GUARD GASKET - GLAND STATOR - MTM NITRILE RUBBER SUCTN. CHAMB. C.I. BS4504 16/11RF SUCTION. CHAMBER EXT. CASTING SUCTION. CHAMBER EXTENSION TUBE END COVER C.I. BS5404 16/11 RF ROTOR (H.C.P.) FLEXISHAFT S.S. (COATED) DRIVE CLAMP ASSEMBLY DRIVE CLAMP PIN SHAFT PIN S.S. DRIVE SHAFT THROWER (NITRILE RUBBER) SUPPORT FOOT MECH SEAL CARRIER ABUTMENT RING ST.STL. 45mm DIA SLEEVE ADAPTOR FLANGE TIE ROD M.S. TIE ROD M.S.
Published information other than that marked certified is to be used as a guide only
4 9 Decs 2007
PARTS NUMBERING SYSTEM The part numbers are made up of four descriptive fields:1. 2. 3. 4. 1. 2. 3. Material Pump Range and Size Item Classification Number Variation Code The material code will be 2 characters i.e. SF, MM, MB. The pump range and size will consist of four characters i.e. C041. The item classification will consist of two numbers and these numbers indicate the standard component.
i.e. 22 = Stator 25 = Rotor 32 = Shaft etc. (See Appendix A) 4. The last two characters the variation code generally indicates the variance from the standard component.
Published information other than that marked certified is to be used as a guide only
4 10 Dec 2007
Published information other than that marked certified is to be used as a guide only
4 11 Dec 2007
MATERIALS MATERIAL CODES Listed below a general list of materials used in the pumps, these are the main materials with high usage and are for a guide only, this is not a complete list and if you have any problems or queries you should contact Monoflo. Description BD CD MQ SB SF SM ST SX TH TO UM ZG Alloy Steel Cast Iron Alloy Steel Stainless Steel Stainless Steel Stainless Steel for Flexishafts Cast Stainless Steel Stainless Steel Tool Steel Tool Steel Titanium Gasket Material
Published information other than that marked certified is to be used as a guide only
4 12 Dec 2007
MATERIALS STATORS CODE RA RE RH RJ RR RV DESCRIPTION Black Natural Rubber Grade A MAXIMUM TEMP F 158 266 230 230 230 302
Ethylene Propylene Rubber (EPR) Chlorosulponated P.E. (CSM) High Nitrile Rubber Nitrile Rubber (NBR) Fluoroelastomer (FKM)
Published information other than that marked certified is to be used as a guide only
4 13 Dec 2007
Operating and Maintenance Instructions will be supplied with your pump. Additional copies can be obtained by contacting your Monoflo Representative.
Published information other than that marked certified is to be used as a guide only
Flange Dimensions Casting Tappings Rotor Dimensions Stator Dimensions Gearbox Cross Drilling Differential and Discharge Pressures
MATERIALS OF CONSTRUCTION
SPEC BS EN 1561 BS EN 1561 BS EN 10088 BS 3100 BS EN 1561 BS EN 10088 BS 3100 BS EN 1561 BS 2789 BS EN 10088 BS 3100 ASTM A322 BS EN 10088 BS 2TA11 BS EN 10088 BS EN 10088 BS EN 10088 BS EN 1561 BS 3100
DESCRIPTION/GRADE EN-GJL-HB195 EN-GJL-HB195 X2CrNiMo17-12-2 316C16F EN-GJL-HB195 X2CrNiMo17-12-2 316C16F EN-GJL-HB195 400/18 or 420/12 X2CrNiMo17-12-2 316C16F 4140 X2CrNiMo17-12-2 T1 - GAL - 4V X17CrN: 16.2 X2CrNiMo17-12-2 X2CrNi18-9 or X12Cr13 EN-GJL-HB195 316C16F
23A
23B
END COVER
24A
CAST IRON STAINLESS STEEL CAST STAINLESS STEEL CAST IRON STAINLESS STEEL CAST STAINLESS STEEL CAST IRON SPHEROIDAL CAST IRON STAINLESS STEEL CAST STAINLESS STEEL ALLOY STEEL STAINLESS STEEL TITANIUM STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CAST IRON CAST STAINLESS STEEL
Published information other than that marked certified is to be used as a guide only
EPSILON
5-2 1
ALL 2
Dec 2007
Pump Model C-1B E-1B C-1D E-1D C-2A E-2A C-2B E-2B C-2D E-2D C-3A E-3A C-3B E-3B C-3K E-3K C-XA E-XA C-XB E-XB C-XK E-XK C-4A E-4A C-4B E-4B C-4K E-4K C-5A E-5A C-5B E-5B C-5K E-5K C-6A E-6A C-6B E-6B C-6K E-6K C-7A E-7A C-7B E-7B C-7K E-7K C-8A E-8A C-8B E-8B C-8K E-8K C-9A E-9A C-9B E-9B C-9K E-9K C-AA E-AA C-AB E-AB C-AK E-AK C-BA E-BA C-BK E-BK E-CA E-DA E-EA
Minimum Dismantling Distance (inch) 4.13 105 4.52 115 4.13 105 4.52 115 4.52 115 3.54 90 3.54 90 3.54 90 4.52 115 4.52 115 4.52 115 3.93 100 3.93 100 3.93 100 4.33 110 4.33 110 4.33 110 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 5.11 130 9.84 9.84 9.84
Recommended Dismantling Distance (inch) 4.52 9.84 4.52 9.84 20.66 6.49 11.81 11.81 5.31 11.81 11.81 9.84 17.91 17.91 12.20 22.44 22.40 14.37 26.77 26.77 16.92 31.49 31.49 18.70 34.64 34.64 20.86 38.97 38.97 24.01 43.30 43.30 25.19 47.63 28.93 40.78 61.92
Published information other than that marked certified is to be used as a guide only
N K1 J3 Q1 H G Q1 H F F1 E K1 J4 J2 J1 J Q K
L1
M1
L1
M1
MODEL E11B B012 B014 E11D E12A B022 E12B B024 E12D E13K B03K B031 E13A E13B B032 MODEL E11B B012 B014 E11D B021 E12A B022 E12B E12D E13K B031 E13A E13B
A1 4.13 4.52 4.13 4.52 4.52 3.54 3.54 3.54 J4 17.24 22.91 17.24 22.91 19.64
B 17.48 23.14 17.48 23.14 37.16 25.59 19.88 25.59 K 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59
C 5.23 5.23 5.23 5.23 5.39 5.39 5.39 5.39 K1 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
D 11/4 11/4 11/4 11/4 11/2 11/2 11/2 11/2 L 3.93 3.93 3.93 3.93 3.93 3.93 3.93 3.93
E 3.66 3.66 3.66 3.66 3.66 3.66 3.66 3.66 L1 2.36 2.36 2.36 2.36 2.91 2.91 2.91 2.91
13.54 13.54 13.54 M 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72
23.54 11.96 11.96 N 3.34 3.34 3.34 3.34 3.34 3.34 3.34 3.34
H 1.57 1.57 1.57 1.57 1.57 1.57 1.57 1.57 P 5.74 5.74 5.74 5.74 5.90 5.90 5.90 5.90
J 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 Q /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16
5
J1 1.53 1.53 1.53 1.53 1.53 1.53 1.53 1.53 Q1 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16
J2
13.38 13.38 13.38 Wt 27.55 31.52 27.33 31.30 51.36 41.44 39.93 41.44
All dimensions in inches Note: D is British Standard pipe (B.S.P. or NPT) designation Rp. Q and Q1 are bolt diameters. Wt is the pump weight in lbs. Flanges are ANSI std.
Published information other than that marked certified is to be used as a guide only
R Q M1 M1 L4 L3 L2 L1 L T S T1 N1 P1 T1 N1 P1 K J H1 H G F P N M 3
Model E11B E11D E12A E12B E12D E13K E13A E13B Model E11B E11D E12A E12B E12D E13K E13A E13B
B 17.48 23.14 17.48 23.14 37.16 25.59 19.88 25.59 L4 17.24 22.91 17.24 22.91 19.64
C 10.55 10.55 10.55 10.55 10.70 10.70 10.70 10.70 M 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 NOTE:
D 1 1 1 1 1 1 1 1 M1 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 N 3.93 3.93 3.93 3.93 3.93 3.93 3.93 3.93
E 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 N1 2.36 2.36 2.36 2.36 2.91 2.91 2.91 2.91
F 5.43 5.43 5.43 5.43 5.43 5.43 5.43 5.43 P 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72
G 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 P1 3.14 3.14 3.14 3.14 3.93 3.93 3.93 3.93
13.54 13.54 13.54 Q 3.34 3.34 3.34 3.34 3.34 3.34 3.34 3.34
23.54 11.96 11.96 S 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94
K 1.57 1.57 1.57 1.57 1.57 1.57 1.57 1.57 T /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16
5
L 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 T1 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16 5 /16
L1 1.53 1.53 1.53 1.53 1.53 1.53 1.53 1.53 Wt 39.24 42.99 39.02 42.99 63.05 52.02 47.39 52.69
D is British Standard Pipe (B.S.P. OR NPT) Designation Rp T and T1 are bolt diameters Wt is pump weight in lbs. Dimensions in inches
Flanges are ANSI std.
Published information other than that marked certified is to be used as a guide only
P N
D1
K1
K1
J3
J2
J1
Q1
L1
M1
Q1
L1
M1
H G
H F E
D 2 3 L 3.93 4.33
D1 2 2 L1 3.14 3.14
All dimensions in inches Note: Q and Q1 are bolt diameters Wt is pump weight in lbs. Flanges are ANSI std.
Published information other than that marked certified is to be used as a guide only
EPSILON
B-2 5
ALL CURRENT
May 2008
R
Q
D1
M1
M1
L3
L2
L1
T S
T1
N1 P1 K J
T1 K
N1 P1
A 33.89 44.29
A1 4.52 4.52
B 22.40 30.94
C 11.49 17.28
D 2 3
D1 2 2
E 1.96 3.14
F 5.43 8.35
G 3.54 5.74
H 14.72 16.85
J 8.18 15.39
K 1.57 1.57
L 0.98 1.26
L1 1.53 3.15
L2 14.56 17.00
L3 8.18 15.39
M 0.59 0.63
M1 0.23 0.23
N 3.93 4.33
N1 3.14 3.14
P 4.72 5.51
P1 4.33 4.33
Q 3.44 4.40
R 7.48 8.94
S 0.94 1.38
T /16 5 /16
5
T1 /16 5 /16
5
Wt 72.75 85.98
NOTE:
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H4
H3
G1
H2
H1
M3
M2
M1
L2
L2
K2 J3
K1 J2 J1
M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K
A 46.85 59.33 54.92 53.66 71.77 63.89 63.97 85.78 76.25 76.14 94.05 90.62 J1 5.74 5.74 5.74 5.74 5.98 5.74 5.98 7.00 5.98 7.00 7.00 7.00
A1 55.08 67.56 63.15 61.89 80.00 72.13 72.20 96.38 84.49 86.73 104.65 101.22 J2 22.71 27.12 27.71 27.04 34.68 27.04 33.62 42.12 33.62 41.53 44.96 41.53
B 37.79 50.27 45.86 44.99 60.86 55.23 54.68 73.22 66.96 65.11 83.03 79.60 J3 16.22 24.29 24.29 18.17 28.85 28.85 22.04 34.33 34.33 25.07 39.56 39.56
C 9.05 9.05 9.05 8.66 10.90 8.66 9.29 12.55 9.29 11.02 11.02 11.02 K1 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
D* 3 3 3 3 3 3 4 4 4 6 6 6 K2 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
E 4.40 4.40 4.40 4.40 4.92 4.40 4.92 5.90 4.92 5.90 5.90 5.90 L1 3.93 3.93 3.93 3.93 4.33 3.93 4.33 5.51 4.33 5.51 5.51 5.51
F 8.93 8.93 8.93 9.13 9.64 9.13 10.03 11.02 10.03 12.20 12.20 12.20 L2 3.93 3.93 3.93 3.93 3.93 3.93 3.93 5.11 3.93 5.11 5.11 5.11
G1 0.62 0.62 0.62 0.62 0.70 0.62 0.70 0.90 0.70 0.90 0.90 0.90 M1 5.51 5.51 5.51 5.51 6.29 5.51 6.29 7.08 6.29 7.08 7.08 7.08
G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 M2 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
H1 1.25 1.25 1.25 1.25 1.49 1.25 1.49 1.73 1.49 1.73 1.73 1.73 M3 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
L1
N2
N2
N1
H2 3.14 3.14 3.14 3.14 2.87 3.14 2.87 3.38 2.87 3.38 3.38 3.38 N 1 ** 3 /8 3 /8 3 /8 3 /8 /2 /8 1 /2 5 /8 1 /2
1 3
H3 22.91 27.32 22.91 27.24 34.72 27.24 33.66 42.44 33.66 42.04 45.47 42.04 N 2 ** 3 /8 3 /8 /8 /8 1 /2 3 /8 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2
3 3
H4 16.22 24.29 24.29 18.62 28.85 28.85 22.04 34.33 34.33 25.07 39.56 39.56
/8 /8 5 /8
5 5
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H4
H3
G1
H2
H1
M3
M2
M1
L2
L2
K2 J3
K1 J2 J1
A 81.25 108.00 97.32 94.29 112.48 112.48 103.46 131.10 124.36 119.19 141.81
A1 91.85 119.45 107.91 105.69 123.86 123.86 114.86 N/A 135.75 N/A N/A
B 70.23 93.58 86.29 81.88 100.07 100.07 91.06 115.23 111.96 103.14 124.96
C 11.06 14.48 11.02 12.40 12.40 12.40 12.40 15.86 12.40 16.85 16.85
D* 6 6 6 8 8 8 8 8 8 10 10
E 5.90 6.29 5.90 6.29 6.29 6.29 6.29 8.85 6.29 8.85 8.85
F 12.20 12.59 12.20 13.58 13.58 13.58 13.58 16.14 13.58 17.71 17.71
G1 0.90 0.86 0.90 0.86 0.86 0.86 0.86 1.18 0.86 1.18 1.18
G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.86 0.86
L1
N2
N2
N1
H1 1.73 1.85 1.73 1.85 1.85 1.85 1.85 2.32 1.85 2.32 2.32
H2 3.38 3.77 3.38 3.77 3.77 3.77 3.77 3.93 3.77 3.93 3.93
H3 41.81 51.65 41.81 46.45 46.45 46.45 52.28 73.73 52.28 78.62 74.99
H4 30.43 46.49 46.49 36.88 55.07 55.07 40.23 45.78 61.14 32.48 57.79
J1 7.00 7.67 7.00 7.67 7.67 7.67 7.67 8.66 7.67 8.66 8.66
J2 41.29 51.37 41.29 46.18 46.18 46.18 52.00 73.11 52.00 78.70 75.07
J3 30.43 46.49 46.49 36.80 55.07 55.07 40.23 45.78 61.14 31.18 56.49
K1 1.96 2.75 1.96 2.75 2.75 2.75 2.75 2.75 2.75 3.54 3.54
K2 1.96 2.75 1.96 2.75 2.75 2.75 2.75 2.75 2.75 3.54 3.93
L1 5.51 6.29 5.51 6.29 6.29 6.29 6.29 9.05 6.29 9.05 9.05
L2 5.11 5.51 5.11 7.87 7.87 7.87 7.87 7.87 7.87 8.66 8.66
M1 7.08 7.87 7.08 7.87 7.87 7.87 7.87 11.02 7.87 11.02 11.02
M2 6.69 7.08 6.69 9.44 9.44 9.44 9.44 10.23 9.44 11.02 11.02
M3 6.69 7.08 6.69 9.44 9.44 9.44 9.44 10.23 9.44 11.02 11.02
N 1 ** 5 /8
5 5 5 5 5 5 5
/8 /8 /8 /8 /8 /8
N 2 ** 1 /2 5 /8 1 /2 5 /8 5 /8
5 5 5 5
/8 /8
/8 5 /8 5 /8
5
/8 /8 3 /4
3
/8
/4
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
DISMANTLING DISTANCE *
F E
G2
G2
H4
H3
G1
H2
H1
M3
M2
M1
L2
L2
K2 J3
K1 J2 J1
M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K
A 38.58 51.06 46.65 45.39 62.89 55.63 55.03 73.23 67.36 63.58 81.77 78.07 J1 5.74 5.74 5.74 5.74 5.98 5.74 5.98 7.00 5.98 7.00 7.00 7.00
A1 46.73 59.17 54.80 53.50 70.98 63.74 63.19 83.78 75.47 74.13 92.24 88.62 J2 14.44 18.86 14.44 18.78 25.79 18.78 24.72 29.57 24.72 28.98 32.91 28.98
B 29.53 42.00 37.60 36.73 51.96 46.97 45.78 60.66 58.07 52.56 70.75 67.05 J3 16.22 24.29 24.29 18.74 28.85 28.85 22.04 34.33 34.33 25.07 39.56 39.56
C 9.05 9.05 9.05 8.66 10.90 8.66 9.29 12.55 9.29 11.02 11.02 11.02 K1 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
D* 3 3 3 3 3 3 4 4 4 6 6 6 K2 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
E 4.40 4.40 4.40 4.40 4.92 4.40 4.92 5.90 4.92 5.90 5.90 5.90 L1 3.93 3.93 3.93 3.93 3.93 3.93 4.33 5.51 4.33 5.51 5.51 5.51
F 8.93 8.93 8.93 9.13 9.64 9.13 10.03 11.02 10.03 12.20 12.20 12.20 L2 3.93 3.93 3.93 3.93 3.93 3.93 3.93 5.11 3.93 5.11 5.11 5.11
G1 0.62 0.62 0.62 0.62 0.70 0.62 0.70 0.90 0.70 0.90 0.90 0.90 M1 5.51 5.51 5.51 5.51 6.29 5.51 6.29 7.08 6.29 7.08 7.08 7.08
G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 M2 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
L1
N2
N2
N1
H1 1.25 1.25 1.25 1.25 1.49 1.25 1.49 1.73 1.49 1.73 1.73 1.73 M3 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
H2 3.14 3.14 3.14 3.14 2.87 3.14 2.87 3.38 2.87 3.38 3.38 3.38 N 1 **
3 3 3 3 1
H3 14.64 19.06 14.64 18.98 25.82 18.98 24.76 29.88 24.76 29.49 33.18 29.49 N 2 **
3 3 3 3 1
H4 16.22 24.29 24.29 18.62 28.85 28.85 22.04 34.33 34.33 25.07 39.56 39.56
/8 /8 /8 /8 /8
/8 /8 /8 /8 /8
/2
3
/2 /2 /2 /2 /2 /2
3 1 1 1 1 1
/2
5
/8 /8 /8 /8
/2
5 5 5
s1
/2
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified
NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
DISMANTLING DISTANCE *
F E
G2
G2
H4
H3
G1
H2
H1
M3
M2
M1
L2
L2
K2 J3
K1 J2 J1
A 68.97 92.87 85.03 79.13 97.32 97.32 88.11 117.83 109.02 104.76 128.58
A1 79.45 104.21 95.51 90.43 108.62 108.62 99.33 N/A 120.24 N/A N/A
B 57.95 78.38 24.02 66.73 84.92 84.92 75.71 101.97 96.61 87.91 111.73
C 11.02 14.44 11.02 12.40 12.40 12.40 15.86 12.40 16.85 16.85 16.85
D* 6 6 6 8 8 8 8 8 8 10 10
E 5.90 6.29 5.90 6.29 6.29 6.29 6.29 8.85 6.29 8.85 8.85
F 12.20 12.59 12.20 13.58 13.58 13.58 13.58 16.14 13.58 17.71 17.71
G1 0.90 0.86 0.90 0.86 0.86 0.86 0.86 1.18 0.90 1.18 1.18
G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.90 0.90
L1
N2
N2
N1
H1 1.73 1.85 1.73 1.85 1.85 1.85 1.85 2.32 1.85 2.32 2.32
H2 3.38 3.77 3.38 3.77 3.77 3.77 3.77 3.93 3.77 3.93 3.93
H3 29.53 36.46 29.53 31.30 31.30 31.30 36.93 60.47 36.93 63.39 61.77
H4 30.43 46.49 46.49 36.88 55.07 55.07 40.23 45.78 61.14 32.48 57.79
J1 7.00 7.67 7.00 7.67 7.67 7.67 7.67 8.66 7.67 8.66 8.66
J2 29.02 36.18 29.02 31.02 31.02 31.02 36.65 59.84 36.65 63.46 61.85
J3 30.43 46.49 46.49 38.88 55.07 55.07 40.23 45.78 61.14 31.18 56.49
K1 1.96 2.75 1.96 2.75 2.75 2.75 2.75 2.75 2.75 3.54 3.54
K2 1.96 2.75 1.96 2.75 2.75 2.75 2.75 2.75 2.75 3.54 3.93
L1 5.51 6.29 5.51 6.29 6.29 6.29 6.29 9.05 6.29 9.05 9.05
L2 5.11 5.51 5.11 7.87 7.87 7.87 7.87 7.87 7.87 8.66 8.66
M1 7.08 7.87 7.08 7.87 7.87 7.87 7.87 11.02 7.87 11.02 11.02
M2 6.69 7.08 6.69 9.40 9.40 9.40 9.40 10.23 9.40 11.02 11.02
M3 6.69 7.08 6.69 9.40 9.40 9.40 9.40 10.23 9.40 11.02 11.02
N 1 **
5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8
N 2 **
1/2 5/8 1/2 5/8 5/8 5/8 5/8 5/8 5/8 3/4 3/4
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified
NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H4
H3
G1
H2
H1
L2
M2
M3
M1
L2
K2 J3
K1 J2 J1
M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K
A 46.85 59.33 54.92 53.66 71.77 63.89 63.97 85.78 73.25 76.14 94.05 90.62 J1 5.74 5.74 5.74 5.74 5.98 5.74 5.98 7.00 5.98 7.00 7.00 7.00
A1 55.08 67.56 63.15 61.89 80.00 72.13 72.20 96.38 84.49 86.73 88.65 101.22 J2 28.77 33.18 28.77 33.26 40.90 33.26 40.98 49.48 40.98 48.22 51.65 48.22
B 37.79 50.27 45.86 44.99 60.86 55.23 54.68 73.22 66.96 65.11 83.03 79.60 J3 10.15 18.22 18.22 12.40 22.63 22.63 14.68 26.96 26.96 18.38 32.87 32.87
C 9.05 9.05 9.05 8.66 10.90 8.66 9.29 12.55 9.29 11.02 11.02 11.02 K1 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
D* 3 3 3 3 3 3 4 4 4 6 6 6 K2 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96
E 4.40 4.40 4.40 4.40 4.92 4.40 4.92 5.90 4.92 5.90 5.90 5.90 L1 3.93 3.93 3.93 3.93 4.33 3.93 4.33 5.51 4.33 5.51 5.51 5.51
F 8.93 8.93 8.93 9.13 9.64 9.13 10.03 11.02 10.03 12.20 12.20 12.20 L2 3.93 3.93 3.93 3.93 3.93 3.93 3.93 5.11 3.93 5.11 5.11 5.11
G1 0.62 0.62 0.62 0.62 0.70 0.62 0.70 0.90 0.70 0.90 0.90 0.90 M1 5.51 5.51 5.51 5.51 6.29 5.51 6.29 7.08 6.29 7.08 7.08 7.08
G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 M2 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
H1 1.25 1.25 1.25 1.25 1.49 1.25 1.49 1.73 1.49 1.73 1.73 1.73
L1
N2
N2
N1
H2 3.14 3.14 3.14 3.14 2.87 3.14 2.87 3.42 2.87 3.38 3.38 3.38 N 1 ** 3 /8 3 /8 3 /8 /8 /2 3 /8 1 /2 5 /8 1 /2
3 1 5
H3 28.97 33.38 28.97 33.46 40.94 33.46 41.02 49.80 41.02 48.74 52.16 48.74 N 2 ** 3 /8 3 /8 3 /8
1 3 /8 /2 3 /8 1 /2 1 /2 1 /2 1 /2 1 /2 1
H4 10.15 18.22 18.22 12.40 22.63 22.63 14.68 26.96 26.96 18.38 32.87 32.87
5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
/8 /8 5 /8
5
/2
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
DISMANTLING DISTANCE *
F E
G2
G2
H4
H3
G1
H2
H1
L2
M2
M3
M1
L2
K2 J3
K1 J2 J1
D* 6 6 6 8 8 8 8 8 8
L1
N2
N2
N1
N 1 ** 5 /8 5 /8 5 /8 5 /8 5 /8 5 /8
5 5
/8 /8 /8
N 2 ** 1 /2 5 /8 1 /2 5 /8 5 /8 5 /8 5 /8 5 /8
5
/8
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified
NOTE: For bareshaft pump dimensions see page 299 & 300
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H4
H3
G1
H2
H1
L2
M2
M3
M1
L2
K2 J3
M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K M ODEL E 14A E 14B E 14K E 15A E 15B E 15K E 16A E 16B E 16K E 17A E 17B E 17K A 38.58 51.06 46.65 45.39 62.87 55.63 55.07 73.23 67.36 63.58 81.77 78.09 J1 5.74 5.74 5.74 5.74 5.98 5.74 5.98 7.00 5.98 7.00 7.00 7.00 A1 46.73 59.27 54.80 53.50 70.98 63.74 63.19 83.78 75.47 74.13 92.24 88.62 J2 20.51 24.92 20.51 25.00 32.00 25.00 32.09 36.93 32.09 35.66 39.37 35.66 B 29.53 42.00 37.60 36.73 51.96 46.97 45.78 60.66 58.07 52.56 70.25 67.05 J3 10.15 18.22 18.22 12.40 22.63 22.63 14.68 26.96 26.96 18.38 32.87 32.87
K1 J2
C 9.05 9.05 9.05 8.66 10.90 8.66 9.29 12.55 9.29 11.02 11.02 11.02 K1 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96 D* 3 3 3 3 3 3 4 4 4 6 6 6 K2 1.57 1.57 1.57 1.57 2.36 1.57 2.36 2.36 2.36 1.96 1.96 1.96 E 4.40 4.40 4.40 4.40 4.92 4.40 4.92 5.90 4.92 5.90 5.90 5.90 L1 3.93 3.93 3.93 3.93 4.33 3.93 4.33 5.51 4.33 5.51 5.51 5.51 F 8.93 8.93 8.93 9.13 9.64 9.13 10.03 11.02 10.03 12.20 12.20 12.20 L2 3.93 3.93 3.93 3.93 3.93 3.93 3.93 5.11 3.93 5.11 5.11 5.11 G1 0.62 0.62 0.62 0.62 0.70 0.62 0.70 0.90 0.70 0.90 0.90 0.90 M1 5.51 5.51 5.51 5.51 6.29 5.51 6.29 7.08 6.29 7.08 7.08 7.08 G2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 M2 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69 H1 1.25 1.25 1.25 1.25 1.49 1.25 1.49 1.73 1.49 1.73 1.73 1.73 M3 5.11 5.11 5.11 5.11 6.06 5.11 6.06 6.69 6.06 6.69 6.69 6.69
L1
N2
N2
N1
J1
H2 3.14 3.14 3.14 3.14 2.87 3.14 2.87 3.38 2.87 3.38 3.38 3.38 N 1 ** 3 /8 3 /8 3 /8 3 /8 1 /2
3 1
H3 20.70 25.13 20.76 25.20 32.05 25.20 32.05 37.24 32.05 36.18 39.88 36.18 N 2 ** 3 /8 3 /8 3 /8 3 /8
s1 3 1 1 1
H4 20.62 18.22 18.22 12.40 22.63 22.63 14.68 29.96 29.96 18.38 32.87 32.87
/2
/8
/2 5 /8 1 /2 5 /8 5 /8 5 /8
/2
/8
/2 /2 1 /2 1 /2 1 /2
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H4
H3
G1
H2
H1
L2
M2
M3
M1
L2
K2 J3
K1 J2 J1
D* 6 6 6 8 8 8 8 8 8
L1
N2
N2
N1
N 1 ** 5 /8 5 /8 5 /8 5 /8
5 5 5
/8
N 2 ** 1 /2 5 /8 1 /2 5 /8 5 /8 /8 /8 5 /8 5 /8
5 5
/8 /8 5 /8 5 /8
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified
NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
F E
G2
G2
H5
G2
H4
H3
G1
H2
H1
M3
L2 M2
L2 M2
M1
L2
K3 J4
K2 J3
K1 J2 J1
M ODEL E 1B A E 1B K M ODEL E 1B A E 1B K
D* 10 10 J4 31.18 56.49
L1
N2
N2
N2
N1
H5 32.48 57.79 N 1 ** 5 /8 5 /8 N 2 ** 3 /4 3 /4
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
A B D C
F E
G2
G2
H5
G2
H4
H3
G1
H2
H1
M3
L2 M2
L2 M2
M1
L2
K3 J4
K2 J3
K2 J2 J1
D* 10 10 J4 31.18 56.49
L1
N2
N2
N2
N1
H5 32.48 57.79 N 1 **
5 5
N 2 **
3 3
/8 /8
/4 /4
* **
D im ensions show n are for pum ps w ith ANSI ports. C learance holes for m etric bolts specified
NOTE: For bareshaft pump dimensions see pages 299 & 300
Published information other than that marked certified is to be used as a guide only
A B D C
F E G2
G2
H4 N2 N2
H3
G1
H2
H1
M3 L2
L2 M2
M1
N1
K2 J3
K1 J2 J1
L1
Published information other than that marked certified is to be used as a guide only
A B D C
F E G2
G2
H4 N2 N2
H3
G1
H2
H1
M3 L2
L2 M2
M1
N1
K2 J3
K1 J2 J1
L1
Published information other than that marked certified is to be used as a guide only
B-2 18
May 2008
Weight = W (lbs) Model E13D E1XD E14D E15D E16D E17D E18D A 53.74 70.70 82.28 102.20 120.39 139.92 151.77 A1 9.05 10.03 30.70 39.56 47.36 54.52 61.22 B 40.74 55.55 64.29 81.29 97.08 111.22 122.59 C 12.99 15.15 17.99 20.90 23.30 28.70 29.17 D 2 3 3 4 6 6 8 D1 2 3 3 4 6 6 8 E 2.91 3.85 3.77 5.07 5.35 6.69 6.69 F 2.36 3.14 3.14 4.33 4.44 5.51 5.51 G 1.96 4.80 4.84 6.10 6.10 7.59 7.59 H 6.49 6.85 7.87 8.93 10.27 12.91 12.91 J 15.47 25.39 31.85 40.27 48.26 54.68 60.03 K 25.47 31.33 34.84 43.81 52.28 58.81 69.05 L 1.77 1.57 1.77 1.77 2.16 3.14 3.14 L1 1.57 1.57 1.77 1.77 2.16 3.54 3.54 M 0.31 0.39 0.39 0.47 0.62 0.78 0.78
U /16 3 /8 1 /2 1 /2 5 /8 5 /8 3 /4
5
U1 /16 5 /16 1 /2 1 /2 5 /8 5 /8 3 /4
L, L1, Q & Q1 = Minimum Foundation Pad Sizes. U, U1 = Holding-Down Bolt Diameters. T = Shaft Diameter Notes: 1. 2. All dimensions in inches and for guidance only. For all certified drawings refer to Monoflo. Shaft diameters are to BD4506:1970 and keyways to BS 4235:1982 Part 1/ISO R773. Dimensions shown are for pumps with ANSI ports.
Published information other than that marked certified is to be used as a guide only
U1
P1 Q1 L1
P1 Q1 L2 J1 J
W = Weight (lbs)
Model E1BB E1CA E1DA E1EA A 163.77 157.91 169.76 227.44 A1 48.62 28.93 40.78 28.93 B 133.54 126.10 137.95 186.96 C 30.23 31.81 31.81 40.47 D 10 10 10 12 D1 10 10 10 12 E 7.08 7.08 7.08 10.15 F 5.86 5.86 5.86 8.62 G 8.11 8.11 8.11 11.49 H 13.18 13.18 13.18 16.18 J 84.80 97.36 97.36 125.23 J1 39.84 51.45 51.45 58.85 K 52.55 33.34 44.76 71.88 L 3.14 3.14 3.14 L1 3.54 3.93 3.93 3.93* L2 3.54 3.93 3.93 3.93 M 0.78 0.78 0.78 1.37
/4 3 /4 3 /4 13/16
3
/4 3 /4 3 /4 15 /16
3
U1
H, H1, Q & Q1 = Minimum Foundation Pad Sizes. T = Shaft Diameter. U = Holding-Down Bolt Diameters. Notes: 1. 2. * All dimensions in inches and for guidance only. For full certified drawings refer to Monoflo Shaft diameters are to BS 4506:1970 and keyways to BS 4235:1982 Part 1/ISO R773 L1 at discharge is 4.92 Dimensions shown are for pumps with ANSI ports.
Published information other than that marked certified is to be used as a guide only
D1 M2 N4 U1 P3 Q3 L2 J2 J3 M2 M2 M1 N5 N3 P1 Q1 U1 L J1 U1 P1 Q1 L J H G N2 Q P U T M N1 N
U1 P2 Q2 L1
W = Weight (lbs) Model E1AD E1BD E1CB Model E1AD E1BD E1CB Model E1AD E1BD E1CB Model E1AD E1BD E1CB A 201.92 242.36 215.94 J 39.68 49.96 58.85 A1 41.14 47.24 28.93 J1 48.85 50.70 55.03 B 171.65 203.07 175.47 J2 45.07 53.54 35.31 C 30.27 39.29 40.47 J3 117.87 210.51 185.74 D 8 10 12 L 3.54 4.52 3.93 D1 8 10 12 L1 3.54 4.52 3.93 E 7.12 10.15 10.15 L2 3.54 4.52 3.93 F 5.94 8.62 8.62 M 0.98 1.37 1.37 G 8.11 11.49 11.49 M1 0.78 0.78 0.78 H 13.18 16.81 16.81 M2 0.86 0.86 0.86
H, H1, Q & Q1 = Minimum Foundation Pad Sizes. T = Shaft Diameter. U = Holding-Down Bolt Diameters. F = keyway length. W = Weight in lbs. Notes: 1. 2. All dimensions in inches and for guidance only. For full certified drawings refer to Monoflo Shaft diameters are to BS 4506:1970 and keyways to BS 4235:1982 Part 1/ISO R773. Dimensions shown are for pumps with ANSI ports.
Published information other than that marked certified is to be used as a guide only
B-2
19
Feb 2008
A SECTION A-A
Pump E14A E14K E14B E15A E15K E15B E16A E16K E16B E17A E17K E17B E18A E18K E18B E19A E19K E19B E1AA E1AK
8.22
3.85
3.14
2.75
1.37
7.87
1.48
0.39
10.59
5.07
4.33
3.93
1.96
9.84
2.09
0.55
11.37
5.35
4.48
3.93
2.16
9.84
2.31
0.62
Published information other than that marked certified is to be used as a guide only
B-2
20
Feb 2008
A B C F
A
SECTION A-A
A 6.69
B 5.51
C 4.72
D 2.75
E 2.72
F 0.78
NB: Bareshaft pumps E1AB, E1BA & E1BK are supplied with an E Range body (E121 0100) All dimensions in inches and for guidance only.
Published information other than that marked certified is to be used as a guide only
B-2
21
Feb 2008
Small Pumps Pump E11B E12A E12B E13A E13B E1XA E1XB Bloc Construction 28.66 26.43 30.86 35.27 41.88 61.79 77.16 1&2 Stage Pumps Pump E14A E14B E15A E15B E16A E16B E17A E17B E18A E18B E19A E19B E1AA E1AB E1BA E1BB E1CA E1CB E1DA E1EA Bloc Construction 83.77 112.43 127.86 189.59 198.41 260.14 277.78 379.19 293.91 429.90 473.99 718.70 568.79 901.68 928.14 n/a n/a n/a n/a n/a Bareshaft 130.07 158.73 174.16 235.89 244.71 328.48 357.14 458.56 403.44 555.56 606.27 850.98 701.06 1056.01 1032.46 1355.84 1267.65 2976.23 1488.11 3582.50 Pump E11D E12D E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD Bareshaft 39.68 39.68 44.09 48.50 52.91 72.75 85.89 Pump E13K E14K E15K E16K E17K E18K E19K E1AK E1BK
K-Build Pumps Bloc Construction 41.88 114.64 143.30 235.89 372.58 423.28 683.43 758.38 1194.90 Bareshaft 52.91 160.93 189.59 282.19 451.94 533.51 815.70 912.71 1349.22
4 Stage Pumps Bloc Construction 30.86 50.70 n/a n/a n/a n/a n/a n/a n/a n/a n/a Bareshaft 41.88 63.93 77.16 123.45 174.16 253.53 399.03 694.45 952.39 1686.53 333.18
Published information other than that marked certified is to be used as a guide only
EPSILON
5-3 1
ALL CURRENT
Feb 2008
Pump size E11B E11D E12A E12B E12D E13A E13K E13B E1XA E1XB
Drive Type
Shaft dia. mm
Flexishaft
32 32
M032139G
1.39 35.5
0.27 7
0.53 13.5
45 45
M045139G
37 1.45
0.31 8
44.0 1.73
Note: All seal working lengths are to DIN L1K dimensions. This table is not to be used for standard or DIN L1N working length seals. All seals use 'M' type seats except for 3.34which uses 'BS' type. This table is not necessarily compatible with any other seal type - check with Monoflo Technical Dept.
Published information other than that marked certified is to be used as a guide only
EPSILON
5-3 2
ALL CURRENT
Feb 2008
Pump Size
Drive Type
Shaft Diameter mm
Flexishaft
45
M045139G
1.45
0.31
1.61
Flexishaft
55
M055139G
1.45
0.39
1.35
Flexishaft
65
M065139G
1.59
0.47
1.31
NOTE: All seal working lengths are to DIN L1K dimensions. This table is not to be used for standard or DIN L1N working length seals. All seals use M type seat except for 3.34 which uses BS type. This table is not necessarily compatible with any other seal type - check with Monoflo Technical Dept.
Published information other than that marked certified is to be used as a guide only
EPSILON
5-3 3
ALL CURRENT
Feb 2008
Pump Size
Drive Type
Shaft Diameter mm
Flexishaft
85
M085139G
1.87
0.49
1.29
85
M085139G
1.87
0.49
2.28
NOTE: All seal working lengths are to DIN L1K dimensions. This table is not to be used for standard or DIN L1N working length seals. All seals use M type seat except for 3.34 which uses BS type. This table is not necessarily compatible with any other seal type - check with Monoflo Technical Dept.
Published information other than that marked certified is to be used as a guide only
EPSILON
5-3 4
ALL CURRENT
Feb 2008
P201
P203
10A
P202
65A
Grub Screw Mechanical Seal Lipseal (Optional) Seal Housing Abutment Ring
66A
66A
P201
P202
Pump Models
Drive Type
E13D
Flexishaft1
M032139G
E1XD
Flexishaft1
M035139G
35
1.35
E14D
Flexishaft1
M045139G
45
1.45
E15D
Flexishaft1
M055139G
55
1.47
E16D
Flexishaft1
M065139G
65
1.59
E17D E18D
Flexishaft1
M085139G
85
1.87
* For seals other than the Crane 2100 please refer to the manufacturer's instructions.
Published information other than that marked certified is to be used as a guide only
EPSILON
5-4 1
ALL CURRENT
May 2008
ANSI FLANGE DIMENSIONS SINGLE & 2 STAGE MODELS PLUS E11D & E12D (INCH)
B E G F A C H
DIA D
Pump Construction
Pump Model(s) E11B E11D E12A E12B E12D E13A E13B E13K
E1XA
Flange Specification
Dimensions A B C
(Number)
H 1 1
NPT THREAD 2 ANSI B16-1 Class 125 3 4 6 8 10 ANSI B16-5 Class 150 (Steel) NPT THREAD 2 3 ANSI B16-5 Class 150 4 8 10 12 12 6 7.5 9 11 13.5 16 19 4.75 6 7.5 9.5 11.75 14.25 17 0.75 (4) 0.75 (4) 0.75 (8) 0.88 (8) 0.88 (8) 1.0 (12) 1.0 (12) 3.62 5 6.19 8.5 10.62 12.75 15 0.75 0.94 0.94 1 1.00 1.12 1.18 1.25 0.06 0.06 0.06 0.06 0.06 0.06 0.11 12 6 7.5 9 11 13.5 16 19 4.75 6 7.5 9.5 11.75 14.25 17 0.62 (4) 0.75 (4) 0.75 (4) 0.88 (8) 0.88 (8) 1.0 (12) 1.0 (12) 15 0.63 0.75 0.94 1.00 1.10 1.18 1.25 0.11
E16A E16B E16K E17A E17B E17K E18A E18B E18K E19A E19B E19K E1AA E1AB* E1AK E1BA* E1BK * E1BB E1CA E1DA E1CB E1EA E11B E12A E12B E12D E13A E13B E13K
E1XA
1 1
E16A E16B E16K E17A E17B E17K E18A E18B E18K E19A E19B E19K E1AA E1AB* E1AK E1BA* E 1BK* E1BB E1CA E1DA E1CB E1EA
All dimensions in inches. * Compatible Flange. ** E1XB suction flange 3NB, discharge flange 2NB
Published information other than that marked certified is to be used as a guide only
EPSILON
5-4 2
ALL CURRENT
May 2008
DIA D
Pump Construction
Pump Models E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD
Flange Specification ANSI B16.1 CLASS 125 ANSI B16.5 CLASS 150 (Steel) ANSI B16.1 CLASS 250
A 2 3 4 6 8 8 10 2 3 4 6 8 10 2 3 4 5 6 8 2 3 4 6 8 10
B 6 7.5 9 11 13.5 13.5 16 6.5 8.25 10 12.5 15 17.5 6 7.5 9 11 13.5 16 6.5 8.25 10 12.5 15 17.5
Dimensions (mm) C D (No.) E 4.75 0.75 (4) 6 0.75 (4) 7.5 0.75 (8) 9.5 0.88 (8) 11.75 0.88 (8) 11.75 0.88 (8) 10.6 14.25 1 (12) 12.75 5 0.75 (4) 4.15 6.6 0.86 (8) 5.7 7.8 0.86 (8) 7 10.6 0.86 (12) 9.7 13 1 (12) 11.8 15.25 1.14 (16) 14 4.75 0.75 (4) 3.6 6 0.75 (4) 5 7.5 0.75 (8) 6.2 9.5 0.86 (8) 8.5 11.75 0.86 (8) 14.25 1 (12) 12.75 5 0.75 (4) 3.6 6.6 0.86 (8) 5 7.9 0.86 (8) 6.2 10.6 0.86 (12) 8.5 13 1 (12) 10.6 15.25 1.14 (16) 12.75
F 0.86 0.75 0.94 1 1.1 1.1 1.18 0.9 1.2 1.3 1.5 1.7 1.9 0.75 0.9 0.9 0.9 1.1 1.2 0.75 1.2 1.3 1.5 1.7 1.9
0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
Published information other than that marked certified is to be used as a guide only
EPSILON
5-5 1
ALL CURRENT
Feb 2008
TAPPINGS
CAST IRON END COVER ST. THRO. PUMP E11B E11D E12A E12B E12D E13K E13A E13B E13D E1XK E1XA E1XB E1XD E14K E14A E14B E14D E15K E15A E15B E15D E16K E16A E16B E16D E17K E17A E17B E17D E18K E18A E18B E18D E19A E19B E1AK E1AA E1AB E1BK E1BA E1BB E1CA E1CB E1DA E1EA " BSP
3
P501
P100232S
P100232S
P100210S
P100210S
/8"
BSP
P100332S
P100332S
P100310S
P100310S
" BSP
P100432S
P100432S
P100410S
P100410S
P100532S
P100532S
P100510S
P100510S
Published information other than that marked certified is to be used as a guide only
Extended Pitch Pump E13K E1XK E14K E15K E16K E17K E18K E19K E1AK E1BK L 13.86 352 16.81 427 18.39 467 594 23.39 28.07 713 830 32.68 917 36.10 1024 40.31 1187 46.73 58.66 1490 Weight lbs 3.2 1.5 2.7 6 10.6 4.8 7.4 16.3 15.8 34.8 25.2 55.6 34.5 76.1 49.4 108.9 163.8 74.3 289 131.1
Single Stage Pump E12A E13A E1XA E14A E15A E16A E17A E18A E19A E1AA E1BA E1CA E1DA E1EA L 184 7.24 205 8.07 243 9.57 284 11.18 346 13.62 419 16.50 482 18.98 528 20.79 593 23.35 678 26.69 816 32.13 40.00 1016 52.16 1325 72.79 Weight lbs 0.4 0.9 3.3 1.5 3.4 1.6 6.2 2.8 11.90 5.4 20.50 9.3 32.40 14.7 19.9 43.9 28.5 62.8 96.1 43.6 165.8 75.2 306.4 139 368.2 167 707.7
Two Stage Pump E11B E12B E13B E1XB E14B E15B E16B E17B E18B E19B E1AB E1BB E1CB L 184 7.24 330 12.99 13.86 352 18.35 466 19.33 491 621 24.45 733 28.86 850 33.46 948 37.32 1055 41.54 1224 48.19 1506 59.29 1956 77.00 Weight lbs 0.43 0.9 0.75 1.7 1.48 3.3 10.4 4.7 5 11 22.3 10.1 17 37.5 27.1 59.7 37.6 82.9 52.6 116 83 183 141 310.9 326 718.7
Four Stage Pump E11D E12D E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD L 12.91 328 641 25.24 25.98 660 825 32.48 924 36.38 1159 45.59 1385 54.53 1643 64.69 1794 70.63 95.98 2438 2942 115.82 Weight lbs 0.76 1.7 3.5 1.58 2.88 6.3 5.51 12.1 20.2 9.15 39.6 17.98 30.15 66.5 108.1 49.04 66.3 146.2 383.6 174 705.5 320
Published information other than that marked certified is to be used as a guide only
STATOR IDENTIFICATION
DIA B
Extended Pitch Pump E13K E1XK E14K E15K E16K E17K E18K E19K E1AK E1BK A 11.34 14.29 17.09 21.65 25.94 30.59 33.94 38.23 44.05 53.31 B 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.75
Weight lbs 5.7 12.1 15.4 28.7 50.7 79.4 103.6 190.0 170.0 293.2
Single Stage Pump E12A E13A E1XA E14A E15A E16A E17A E18A E19A E1AA E1BA E1CA E1DA E1EA A 5.47 5.63 7.09 9.02 11.42 13.66 16.10 17.87 20.04 23.15 27.99 34.21 46.06 67.91 B 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.75 12.74 12.74 15.98
Weight lbs 2.9 2.9 6.2 8.8 15.4 24.3 39.7 52.9 97.0 90.4 152.1 202.8 264.6 928.1
Two Stage Pump E11B E12B E13B E1XB E14B E15B E16B E17B E18B E19B E1AB E1BB E1CB A 5.47 11.14 11.34 14.30 17.09 21.65 25.94 30.59 33.94 38.23 44.05 53.30 USES 2 X E1CA B 2.24 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09 8.27 8.74 10.74
Weight lbs 2.9 6.0 5.7 12.1 15.4 28.7 50.7 79.4 103.6 189.6 169.8 293.6
Four Stage Pump E11D E12D E13D E1XD E14D E15D E16D E17D E18D E1AD E1BD A 11.14 22.44 23.11 28.98 33.15 42.13 50.55 59.61 66.10 USES 2 X E1AB USES 2 X E1BB B 2.24 2.24 2.56 3.27 3.74 4.72 5.71 6.30 7.09
Weight lbs 5.7 12.1 11.66 24.64 17.16 57.2 101.2 152.8 204.6
All dimensions in inches Note: The above dimensions and weights being approximate only, are intended to serve as a guide to component identification where this is in doubt.
Published information other than that marked certified is to be used as a guide only
EPSILON
5-8 1
ALL CURRENT
Feb 2008
0.07 A
D H P.C.D.
Aj6
Fj6
ANTI-PISTONING GROOVE, 0.1 DEEP OVER LENGTH C (POSITION AROUND SHAFT OPTIONAL). NOTE: THIS FEATURE IS NOT REQUIRED IF EXISTING KEYWAY IS SUPPLIED (SEE NOTE ABOVE) B* NOTE: *DIM B REPRESENTS LENGTH OF SHAFT FROM FLANGE TO FACE & MINIMUM WORKING LENGTH OF SHAFT AT DIAMETER A NOTE: FACE MOUNT OPTIONS CAN BE OFFERED (Eg D80C FACE MOUNT) IF FLANGE NOT AVAILABLE. Pump Body Pump Size Aj6
(mm)
J 4 OFF
D H11
E 4.72
J
5 3
Build Ref. M G F E B A
/16 /8 /8 /8 /8 /8
32 32 32 32 32 32
E11B E11D E12A E12B E12D E13K E13A E13B E1XK E1XA
19
1.57
0.71 0.70
0.23
3 3 3 3
20
1.57
0.71 0.70
0.23
5.51 6.29
Published information other than that marked certified is to be used as a guide only
EPSILON
5-8 2
ALL CURRENT
Feb 2008
0.1 A
D H P.C.D.
Ak6
Fj6
ANTI-PISTONING GROOVE, 0.1 DEEP OVER LENGTH C (POSITION AROUND SHAFT OPTIONAL). C
NOTE: *DIM B REPRESENTS LENGTH OF SHAFT FROM FLANGE FACE & MINIMUM WORKING LENGTH OF SHAFT AT DIAMETER A B*
I 4 OFF
Pump Body
Ak6
(mm)
D H11
E 7.87
I
7
Build Ref. A B A B A
30
3.14
2.16 2.14
0.44 6.29
3
45 45 55 55 65
30
3.14
2.16 2.14
0.44
7 9 9
0.15 10.43
40
3.93
2.36 2.34
65
0105
E18B E19A 9 E19K E19B E1AA E1AK B E1AB E1BA E1BK 60 4.72 50 4.72
2.75 2.73
85 85 85 85
A B A B
0.15
2.75 2.73
0.71
11.81 13.70
11
Published information other than that marked certified is to be used as a guide only
PUMP
EPSILON
SECTION
PAGE DATE
5-9
1 Feb 2008
VOLUME
CURRENT
EPSILON MAXIMUM DIFFERENTIAL AND DISCHARGE PRESSURES FOR BRITISH STANDARD PORT FITTINGS AS SH OWN FOR EACH PUMP MODEL & SIZE
MAX. DIFFERENTIAL PRESSURE - PSI SOG Stages Pump Size 1 2 3 X 4 5 6 7 8 9 A B C D E 87 87 87 87 87 87 87 87 87 87 87 87 174 174 174 174 174 174 174 174 174 174 174 174
* 12-165 rpm 6-270 rpm
MAX. DISCHARGE PRESSURE - PSI SOG D 232 232 232 232 232 232 232 232 232 A B 232 232 232 232 232 232 232 232 232 232 232 232 232 D 362 362 580 580 580 580 580 580 580 A DOG B 232 232 232 232 232 232 232 232 232 232 232 232 232 D 232 232 232 232 232 232 232 232 232
DOG D 348 348 348 348 348 348 348 348 348 A B 130 130 130 130 130 130 130 130 130 130 130 130
* 9-225 rpm 6-270 rpm
65 65 65 65 65 65 65 65 65 65 65 65
* 4.5-250 rpm 3.5-370 rpm
232 232 232 232 232 232 232 232 232 232 232 232 232
232 232 232 232 232 232 232 232 232 232 232 232 232
65
232
232
NOTE 1) Figures shown are based on temperatures of 68F. If operating temperatures are excessive (above 122F) contact Monoflo to confirm pressure ratings. 2) SOG : Suction on Gland DOG : Delivery on Gland 3) For the optional port fittings contact Monoflo to confirm maximum pressure ratings when high temperatures are experienced. * Limited to pressures at speeds shown, eg: 174 PSI at 165rpm, 87 PSI at 270rpm.
Published information other than that marked certified is to be used as a guide only
EPSILON
K BUILD ONLY
5-9
2 Feb 2008
CURRENT
MAX. DISCHARGE PRESSURE SOG 232 232 232 232 8 232 232 232 232 8 232 DOG 232 232 232 232 232 232 232 232 232
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
EPSILON
ALL
SECTION
6 1
PAGE
DATE
STATUS
CURRENT
Mar 2008
Published information other than that marked certified is to be used as a guide only
6 2
May 2008
Description Epsilon Vertical 2008 98.6 gpm @ 1000 rpm 162.9 gpm @ 800 rpm 250.9 gpm @ 700 rpm 347.8 gpm @ 600 rpm 427.0 gpm @ 500 rpm 550.3 gpm @ 450 rpm 726.4 gpm @ 400rpm 990.6 gpm @ 350 rpm Single stage Two stage Single stage - extended pitch Cast Iron Stainless steel Code 1 Code 5 Code 8 Mk 0 (Oversized) Mk1 (Standard) Mk3 (Temperature) Mk5 (Temperature) RA, RR etc. Mechanical Seal - Std Flexishaft Packed Gland - Std Flexishaft Mechanical Seal - Short Flexishaft Packed Gland - Short Flexishaft Refer to product manual section 2 & 3, selections
For special requirements contact Monoflo
Standard Variation 12 13 14 15
A B K C S 1 5 8
Rotor Mk No Stator Material Flexishaft / Seal Type Build Option / Variation Example
0 1 3 5 R M P R S
drive
A B
/ A 1 2 3
P Epsilon Vertical
1 Design Mk 1
6 Size 06
1 Mk 1 Rotor
R M A ech Seal - St. Stl Flexi Mech Seal - Std Flexi Build Option A Nitrile Stator
Published information other than that marked certified is to be used as a guide only
6 3 May 2008
P 14A P 14B P 14K P 15A P 15B P 15K P 16A P 16B P 16K P 17A P 17B P 17K P 18A P 18B P 18K P 19A P 19B P 19K P 1A A P 1A B P 1A K P 1B A P 1B K
A 46.85 59.33 54.92 53.66 71.77 63.90 63.98 85.79 76.26 76.14 94.06 90.63 81.26 108.07 97.32 94.29 112.48 112.48 103.46 131.10 124.37 120.00 141.81
B 30.91 43.39 38.98 36.46 53.82 46.69 43.03 64.29 55.31 52.68 69.25 67.17 55.24 81.18 71.30 66.77 84.96 84.96 75.94 102.64 96.85 84.53 106.34
C 6.38 6.38 6.38 7.36 7.36 7.36 9.96 9.96 9.96 11.93 11.93 11.93 13.90 13.90 13.90 13.86 13.86 13.86 13.86 13.86 13.86 19.80 19.80
D 9.57 9.57 9.57 9.84 10.59 9.84 10.98 11.54 10.98 11.54 12.87 11.54 12.13 12.99 12.13 13.66 13.66 13.66 13.66 14.61 13.66 15.67 15.67
H J
E 1.18 1.18 1.18 1.18 1.18 1.18 1.22 1.22 1.22 1.22 1.22 1.22 1.22 1.22 1.22 1.34 1.34 1.34 1.34 1.54 1.34 1.54 1.54
F 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.26 1.26 1.26 1.26 1.42 1.26 1.42 1.42
H 15.94 15.94 15.94 15.94 15.94 15.94 18.11 18.11 18.11 18.11 18.11 18.11 18.11 18.11 18.11 20.47 20.47 20.47 20.47 25.20 20.47 25.20 25.20
J 12.60 12.60 12.60 12.60 12.60 12.60 14.88 14.88 14.88 14.88 14.88 14.88 14.88 14.88 14.88 17.24 17.24 17.24 17.24 21.65 17.24 21.65 21.65
K 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 16 16 16 16 20 16 20 20
L 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.18 1.02 1.18 1.18
M 13.98 13.98 13.98 13.98 13.98 13.98 16.14 16.14 16.14 16.14 16.14 16.14 16.14 16.14 16.14 18.50 18.50 18.50 18.50 23.03 18.50 23.03 23.03
Published information other than that marked certified is to be used as a guide only
W, M, CP
ALL 1a
INDEX
Published information other than that marked certified is to be used as a guide only
W ALL CURRENT
1 1
March 2007
PUMP SIZING 1 From the pre-selection table (page 5) select the pump model which initially meets the required capacity / pressure criteria. (Refer to NOTES on page 4) 2 If particle size is a factor then refer to the table labelled SOLIDS HANDLING (mm) on the performance graph to verify the pumps suitability. 3 If variable speed is required then select at maximum capacity. 4 On the y-axis (Capacity) identify the required flow then move horizontally until intersection at the required differential pressure. 5 Slip Correction for Viscosity a) If Viscosity is equal to or greater than six (6) stokes then select on the zero bar pressure line to determine the pump speed required for the duty. From the point of intersection on the curve move vertically down to the x-axis labelled Speed to obtain the required RPM. b) If the viscosity is less than six (6) stokes then the following procedure applies:Use the method given here as Figs. 1 and 2 to estimate Slip and calculate the required pump speed. Slip Correction for Viscosity n = np - [ (np - no) f ] or n = np - f.ns where n = corrected duty speed no = rpm at zero bar for duty flow rate (from water performance curves) np = rpm at duty pressure for duty flow rate (from water performance curves (Fig 1)) np-no = Slip speed = ns From viscous slip curve (Fig 2) read slip factor f f x ns = slip speed correction = f.ns Corrected Speed for Duty n = np - f.ns
Example
176 PERFORMANCE CURVES O BASED ON WATER AT 68 F CAPACITY gallons/minute 132
SI 0P
88
58
PS
44
no
100 200 300 400
np
500
SPEED RPM
Fig 1 Duty 88 Gallons/Minute, 58 PSI 100 centistokes (viscosity in pump) Corrected Duty Speed n = np - [ (np - no) f ] n = 410 - [ (410-300) x .78 ] = 324 rpm or n = np - f.ns n = 410 - 85.5 = 324 rpm
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Fig 2 Note: There is no slip correction necessary for water or product with a viscosity of one (1) centistoke.
1 2
March 2007
6 When RPM is established identify: a) Maximum viscosity as indicated at the top of the performance curve labelled Viscosity Limits. Refer to page 4, Tolerance guidelines Viscosity Limits. b) Abrasion capability as indicated at the top of the performance curve labelled Abrasion zone. Refer to page 4, Tolerance guidelines Abrasion zone
Information obtained from the PUMP DRIVE CONFIRMATION section will be used to determine the required drive. 1 If product is water like, then the absorbed power (BHP) will be as obtained in the PUMP SIZING section, step 6, item (c). Go to step 4. 2 Multiplying the pump starting torque by the starting torque factor obtained in the PUMP CONFIRMATION section, item 2 will give you the starting torque required for the given viscosity. (ie T(Nm) x fT = Starting torque at viscosity).(Refer to section DRIVE, items 5 and 6) 3 To obtain the power absorbed at the known viscosity then the full viscous calculation is: Viscous Brake Horsepower (V BHP) = Viscous frictional H.P. + W.H.P. a) Viscous Frictional Horsepower FHP x f FHP. FHP as identified in Pump Sizing section step 6, item (c) (zero bar pressure). f FHP factor as identified in Pump Confirmation section step 2. Multiply FHP by correction factor f FHP to give frictional horsepower when handling the viscous product. b) Water Horsepower (WHP) is BHP - FHP BHP as identified in Pump Sizing section step 6, item (c) (at duty pressure). FHP as identified in Pump Sizing section step 6, item (c) (at zero bar pressure). WHP is BHP - FHP c) Add viscous frictional horsepower to water horsepower to obtain BHP absorbed when handling a viscous product i.e. a + b. 4 Determine the motor input power required by allowing for the efficiency of the drive arrangement as follows: Close coupled pumps only Drive Arrangement. Efficiency % D.C. to a synchronous speed motor 100 D.C. to a fixed speed geared motor 92 D.C. to a variable speed geared motor 80 (D.C. = Direct Coupled)
If any of the parameters in steps 1 to 6 (b) do not meet the required criteria then re-select from (1) above with the next larger pump size.
c) Rotor selection against temperature as indicated in the shaded area of the performance curve for the duty speed identified. Refer to Tolerance guidelines - Rotor selection. d) Absorbed power which is read on the y-axis (Absorbed power) at the differential pressure intersection point (BHP). If the product is viscous then note also the absorbed power on the zero pressure line (FHP) for use later in calculation. 7 If the pump meets the above criteria go to the PUMP CONFIRMATION SECTION. If no pump can be identified then please contact Mono Pumps Ltd for assistance. PUMP CONFIRMATION Having determined the pump size the following steps are necessary: 1 Note the starting torque required on the performance curve in the table labelled STARTING TORQUE against the selected rotor. 2 If the product is viscous obtain both Starting Torque (f T) and Power Additive (f FHP) factors from the Viscosity Curve graph read at the known viscosity in Stokes. 3 Confirm stator suitability for the product. (Refer to page 3, Tolerance guidelines - Stator selection) 4 Confirm material compatability and availability for the pump chosen. 5 Confirm availability of packed gland or mechanical seal for the pump chosen.
W ALL CURRENT
1 3 Oct 2007
SELECTION PROCEDURE
Standard pumps Drive Arrangement D.C. to a synchronous speed motor D.C. to a fixed speed geared motor D.C. to a variable speed geared motor Vee drive (D.C. = Direct Coupled) Efficiency % 100 92 80 97 Bridging and Blocking When product characteristics are such that bridging or blocking of the pump inlet hopper is likely, then the possible selections are: i) Pump fitted with large diameter helical conveyor. ii) Pump fitted with integral bridge breaker. Not available on W032, W034. Bridge Breaker Drive Selection Two drive types are available: fixed or variable speed: Fixed Speed: To be used when bridging or blockage is likely to be intermittent or a rare occurrence. Variable Speed: To be used when bridging or blockage is inevitable, ensuring the most efficient operating speed for the breaker can be achieved. Select the drive type required from the bridge breaker driver selection charts in this section. IMPORTANT NOTE ON SELECTION WHEN HANDLING DE-WATERED SLUDGES IN THE REGION OF 20% DRY SOLIDS AND OVER, ESPECIALLY WHEN THERE IS THE LIKELIHOOD OF BLOCKING OR BRIDGING, REFERENCE SHOULD ALWAYS BE MADE TO "MONOFLO". FOR THE CORRECT SELECTION TO BE VERIFIED. TOLERANCE GUIDELINES Rotor Selection As standard, all W range use Mk 0 rotors. Consider maximum fluid temperature, ambient temperature, operating speed and duration of running. All these factors affect stator temperature, in borderline cases select the higher temperature rotor. Fixed speed If selection falls exactly between rotor types then select the higher temperature rotor. Variable speed For variable speed drives select the rotor at maximum speed and maximum temperature. Stator Selection Performance curves based on RR and RA stator materials. Other stator material codes are contained in the stator selection for each model. Please note that the following must be adhered to when selecting the stator grades: (RH) Refer to page 7 to identify starting torque and temperature rotor requirements.
Therefore input power = BHP (or vBHP) divided by the efficiency (ie. Input power required for a close coupled W pump with a direct coupled fixed speed geared motor = BHP (or vBHP) / 0.92) 5 Starting torque capabilities will be affected by the type of drive selected and method of starting. Generally motors wired for D.O.L. start on a 3 phase supply will provide 200% FLT (Full Load Torque). Motors wired for Star/Delta start on a 3 phase supply typically provide 50-70% FLT. Single phase motors (capacitor start) typically provide 200% FLT. In all cases reference should be made to the motor manufacturers performance tables. D.O.L. is the preferred method of starting a PC pump. 6 If starting is via an inverter type of drive then 125% FLT availability only is assumed. The correct matching of drive motor/inverter/pump is a specialised skill. Breakout torque and continuous slow running can cause problems. Always refer an inverter application to a specialist drive company, ensuring that they are aware of the full duty parameters to enable them to select the appropriate drive package. 7 Starting with a soft starter should be referred to the manufacturers specification, but typically starting torque will be 150% FLT. 8 Care should be taken when selecting other types of drives to ensure sufficient starting torque is available, i.e. single phase, hydraulic drives, air motors, engines etc. If in doubt refer to Monoflo.
Published information other than that marked certified is to be used as a guide only
W ALL CURRENT
1 4
Oct 2007
(RV) Refer to page 9 for limitations on speed & pressure The power absorbed must be increased by a factor of 1.2 Applications above 50oC (88oF) should be refered back to Mono Pumps Ltd.
TEMPERATURE LIMITATIONS Tempe rature limitations are dependant on material combinations used. If duty temperatures are outside the limits shown for a particular combination please contact Monoflo for guidance. W Range The normal maximum running temperature is 212F which is the limitation of the joint seal covers. SPEED LIMITAT IONS If speeds below 50rpm are required then please contact Monoflo for assistance.
Flow Rate The expected accuracy of progressing cavity pumps is 10% of pump maximum flowrate as shown by the Product Manual Curves. If specific duty points must be achieved ensure that Monoflo are aware of this. Viscosity limits The viscosity limits are shown in logarithmic scale and indicate maximum recommended viscosities in the pump for the speed selected. Abrasion zone The abrasion zone provides a guide to the pumps ability to handle abrasive products at different speeds with acceptable component life. Pressure has a proportional effect on wear therefore increasing the number of stages at constant pressure will significantly improve component life. NOTES PUMP ROTATION The pump rotation is anti-clockwise (when looking on the pump drive shaft end) such that SOG (Suction-On-Gland) flow conditions prevail (ie, product enters at the hopper and leaves at the discharge chamber). The W Range of pumps cannot be operated in reverse. PRESSURE LIMITATIONS The construction of each different range of pumps will result in maximum discharge pressures and maximum differential pressures that may differ depending upon the specific model, direction of rotation and port fittings. For W Range limitations refer to Section 1 page 8. It is therefore important to check that both the differential pressure plus the inlet pressure do not exceed the maximum discharge pressure for the pump selected.
1 5
ALL CURRENT
March 2007
947
W161
682
W151
379
W121
216
W122
W124
W101
CAPACITY (gallons/minute) 176
W102 W104
W091
150
W092
W081
125
W082
W071
77
W072
W074
W061
45
W062
W051
23
W052
W054
W041
5.2
W042
W031
0 0 87
W032
174
W034
348 522 696
PRESSURE (PSI)
Published information other than that marked certified is to be used as a guide only
1 6
A LL CURRE NT
March 2007
W 0 0 0 0 0 0 0 1 1 1 1 3 4 5 6 7 8 9 0 2 5 6 1 2 4 6 8 A B C D H J H D E S L B C 1 2 A 3
PUMP STAGES
PACKED GLAND PUMP DESIGN DESIGN NUMBER STATOR MAT'L ROTATING PARTS TYPICAL BASIC PUMP CODING
'G' - Standard Bloc 'H' - Standard Bareshaft 'C' - Bareshaft - Mono Australia Only C W 0 6 4 C E 'A' - ANSI + Access Ports 'E' - Standard ANSI 'J' - Japan FULL PUMP CODING TO BE STAMPED ON PUMP NAMEPLATE
Published information other than that marked certified is to be used as a guide only
1 7 March 2007
NO SELECTION
MARK 5 ROTOR
10
% of rated speed
When selecting pumps fitted with RH stators please use the above rotor selection chart which indicates rotor type and recommended pump breakout torque multiplier for a given fluid temperature. The torque multiplier is required to allow for increased interference between rotor and stator. NOTES 1 Mark zero rotors are not to be used with RH stators. 2 3 Rated speed is the maximum speed shown for each pump model as indicated on the appropriate performance curve. If the pump is to be operating for less than 15 minutes per hour then select the next larger rotor size. (ie. if mark 5 rotor is initially selected then select mark 3 ).
1 8
March 2007
ALL CURRENT
W RANGE 2 & 4 STAGE MAXIMUM DIFFERENTIAL & DISCHARGE PRESSURES FOR BRITISH STANDARD/ANSI PORT FITTINGS FOR STANDARD BUILD AND LARGE AUGER AS SHOWN FOR EACH PUMP MODEL AND SIZE MAX. DIFFERENTIAL PRESSURES PSI SOG Stages 1 2 4 6 8 Pump Size 03 87 174 348 174 348 522 696 87 04 174 348 05 87 87 174 348 522 696 06 07 348 87 174 08 87 174 348 522 696 174 09 87 10 87 174 348 12 174 348 87 87 15 87 16 MAX. DISCHARGE PRESSURES PSI SOG 1 2 4 8 6 116 116 116 116 116 116 116 116 116 116 116 203 203 203 203 203 203 203 203 203 377 377 377 377 377 377 377 377 551 551 551 725 725 725
W RANGE 2 & 4 STAGE MAXIMUM DIFFERENTIAL & DISCHARGE PRESSURES FOR JIS PORT FITTINGS FOR STANDARD BUILD AND LARGE AUGER AS SHOWN FOR EACH PUMP MODEL AND SIZE MAX. DIFFERENTIAL PRESSURES PSI SOG Stages 1 2 4 6 8 Pump Size 154 290 87 03 154 87 04 290 154 05 290 87 06 290 154 87 07 154 290 87 08 290 87 154 09 154 87 10 154 290 87 154 87 290 12 15 87 87 16
NOTE 1) 2) 3) Figures shown are based on temperatures of 68F. If operating temperatures are excessive (above 122F) contact Monoflo to confirm pressure ratings. For the optional port fittings, contact Monoflo to confirm maximum pressure ratings w hen high temperatures are experienced. For Bridge Breaker models, reduce discharge pressure by 14.5 PSI.
MAX. DISCHARGE PRESSURES PSI SOG 6 1 2 4 8 116 116 116 116 116 116 116 116 116 116 116 174 174 174 174 174 174 174 174 174 319 319 319 319 319 319 319 319
Published information other than that marked certified is to be used as a guide only
1 9
ALL CURRENT
OCT 2007
SPEED / PRESSURE DERATE WHEN USING RV STATORS (UP TO 50oC) (880F) (Moulded to metal stators only)
100%
NOT SUITABLE
75%
Rated Speed
50%
25%
W
032
2 03201
March 2007
CURRENT
1000
500
Viscosity Limits (Stokes)
100
70
230 212
140 104 68 0
MARK 0
116
174
Limit for water like products Capacities below this line require verification by Monoflo. PSI
174 145 116 87 58 29 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.n s)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68C using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.2
0.75
26
18.5
18.5
18.5
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monflo. Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RJ Black High Nitrile W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
informatio n
oth er
than
that
marked
cer tified
is
to
be
used
as
gu ide
o nly
2 03203
March 2007
032 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP Bareshaft Yes Monobloc
Ye s
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Refer to Monoflo Internal dimensions (mm) See Volume 2 Options Refer to Monoflo
RANGE W COMMENTS
Orientation Vertical
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION Option Refer to Monoflo Standard 1 BSP Option 1 NPT
RANGE W COMMENTS
Orientation Horizontal
SEAL RANGE BODY SIZE B031 Mk1 SHAFT FOR SEAL 32 STANDARD TYPE PG CI Pump Graphited Acrylic/ Glass Yarn SS Pump Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
W COMMENTS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal. Refer to Volume 2 for full gland details.
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 032
SECTION PAGE
DATE
2 03204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
034
2 03401
March 2007
CURRENT
1000
500
Viscosity Limits (Stokes)
100
70
230 212
140 104
MARK 0
116
68 0
232
348
Limit for water like products Capacities below this line require verification by Monoflo
348 232 116 0
PSI
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.2
0.75
52
37
37
37
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1 1
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo. Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
in formation
o ther
th an
th at
marked
cer tified
is
to
b e
used
as
g uide
only
2 03403
March 2007
034 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Ye s Yes AVAILABLE No BRIDGEBREAKER FIXED SPEED No VARIABLE SPEED No LARGE AUGER BARESHAFT No MONOBLOC No
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OPTION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION STANDARD BS EN 1092 Section 3.2 PN 40 BS EN 1092 Section 3.1 PN 40 OPTION ANSI B16.5 Class 300 RF JIS B2210 20 kgf ANSI B16.5 Class 300 RF JIS B2210 20 kgf NOM BORE (mm) See Vol 2 See Vol 2
RANGE
SEAL
RANGE W COMMENTS
STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG
Refer to Vol 2
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 034
SECTION PAGE
DATE
2 03404
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
041
2 04101
March 2007
MEDIUM
CURRENT
1000
500
Viscosity Limits (Stokes)
100
230 212 176
MARK 3 25
15
10
5 Limit for water like products Capacities below this line require verification by Monoflo
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.22
37
22
22
22
Published information other than that marked certified is to be used as a guide only
Temperature (F)
W 041 CURRENT
VISCOSITY ADDITIVES
2 04102
March 2007
10000
STARTING TORQUE POWER ADDITIVE
1000
100
10
0.1
0.01
4
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo. Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) None Yes -5C (32F) None Yes 110C (230F) 110C (230F) Black Natural W RA Black
Chlorosulphonated PE
W RH Black
W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
2 04103
March 2007
041 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Ye s
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OPTION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STA NDARD OPTION NOM BORE (mm) See Vol 2 See Vol 2
RANGE
ORIENTATION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B041 SHAFT FOR SEAL (mm) 45 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 041
SECTION PAGE
DATE
2 04104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
042
2 04201
March 2007
CURRENT
DATA
100
Abrasion Zones
60
230 212
25
MARK 3 MARK 1
PSI
140 104 68 0
20 MARK 0
58 116
15
174
10
Limit for water like products Capacities below this line require verification by Monoflo
PSI
174 116 58 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.22
66
37
37
37
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
information
oth er
th an
th at
marked
cer tified
is
to
be
used
as
gu ide
o nly
2 04203
March 2007
042 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OPTION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICA TION OPTION STANDARD OPTION NOM BORE (mm) See Vol 2 See Vol 2
RANGE
ORIENTATION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B041 SHAFT FOR SEAL (mm) 45 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 042
SECTION PAGE
DATE
2 04204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
044
2 04401
March 2007
CURRENT
1000
500
Viscosity Limits (Stokes)
100
60
230 212
25
MARK 3 MARK 1
PSI
140 104
20 MARK 0 15
145 217
68 0
10
348
5 Limit for water like products Capacities below this line require verification by Monoflo
6.0
PSI
348
4.0
290 217
2.0
145 72 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.22
110
74
74
74
Published information other than that marked certified is to be used as a guide only
Temperature (C)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes 5C (41F) 150C (300F) Yes. Section 4 No W RA Black Natural W RH W RJ W RR Black Nitrile W RV Black Fluoroelastomer
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Pu blished
info rmation
other
than
that
marked
cer tified
is
to
be
u sed
as
guid e
on ly
2 04403
March 2007
044 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS
PUMP BRIDGEBREAKER
AVAILABLE Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION
OPTION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD BS EN 1092 Section 3.2 PN 16 BS EN 1092 Section 3.1 PN 16 OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf NOM BORE (mm) See Vol 2 See Vol 2
RANGE
SEAL RANGE W COMMENTS BODY SIZE B061 SHAFT FOR SEAL (mm) 55 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 044
SECTION PAGE
DATE
2 04404
March 2007
STATUS
CURRENT
DRIVE SELECTION
350 rpm
W
051
2 05101
March 2007
MEDIUM 50
230 212
CURRENT
1000
500
Viscosity Limits (Stokes)
100
MARK 3 60 MARK 1
140 104
50
MARK 0
PSI
0 29 58 87
68 0
40
30
20
10 Limit for water like products Capacities below this line require verification by Monoflo 0 3.0
PSI
87
2.0
58
1.0
29 0
0 Rotor Selection
100
300
350
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.4
1.57
63
37
37
37
Published information other than that marked certified is to be used as a guide only
Temperature (C)
176
2 05102
March 2007
10000
STARTING TORQUE
1000
POWER ADDITIVE
100
10 1
0.1 0.01 1
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) None Yes -5C (32F) None Yes 110C (230F) 110C (230F) Black Natural W RA Black
Chlorosulphonated PE
W RH Black
W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
051 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OP TION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
OPTION
STA NDARD
OPTION
90 end cover ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 Can be rotated JIS B2210 10 kgf BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B041 SHAFT FOR SEAL (mm) 45 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 051
SECTION PAGE
DATE
STATUS
CURRENT
DRIVE SELECTION
W
052
2 05201
March 2007
MEDIUM 50
230 212
CURRENT
1000
500
Viscosity Limits (Stokes)
100
50
MARK 3 MARK 1
PSI
40 MARK 0 30
0 87 130 174
140 104 68 0
20
10 Limit for water like products Capacities below this line require verification by Monoflo
PSI
174 130 87 43 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.4
1.57
118
74
74
74
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
info rmation
other
than
that
marked
certified
is
to
be
u sed
as
guid e
on ly
2 05203
March 2007
052 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Ye s
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION
OPTION
RANGE
OPTIONS
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B061 SHAFT FOR SEAL (mm) 55 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 052
SECTION PAGE
DATE
2 05204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
054
2 05401
March 2007
CURRENT
MEDIUM 50
230 212
1000
500
Viscosity Limits (Stokes)
100
50
MARK 3 MARK 1
PSI
40 MARK 0 30
0 217 348
140 104 68 0
20
10 Limit for water like products Capacities below this line require verification by Monoflo
PSI
348 290 217 145 72 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.4
1.57
258
110
110
110
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
info rmation other than that marked cer tified is to be u sed as a guid e on ly
Pu blished
2 05403
March 2007
054 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Ye s
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICA TION OP TION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STA NDARD BS EN 1092 Section 3.1 PN 40 BS EN 1092 Section 3.1 PN 40 OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf NOM BORE (mm) See Vol 2 See Vol 2
RANGE
SEAL RANGE W COMMENTS BODY SIZE B071 SHAFT FOR SEAL (mm) 65 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 054
SECTION PAGE
DATE
2 05404
March 2007
STATUS
CURRENT
DRIVE SELECTION
350 rpm
W
061
2 06101
March 2007
CURRENT
MEDIUM 50
Viscosity Limits (Stokes)
1000
500
100
230
60
MARK 0
58
87
40
20
Limit for water like products Capacities below this line require verification by Monoflo
PSI
87 58 29 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.89
103
63
63
63
Published information other than that marked certified is to be used as a guide only
Temperature (F)
2 06102
March 2007
100000
VISCOSITY ADDITIVES
1000
STARTING TORQUE
POWER ADDITIVE
100
10
0.1 0.01 1
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) None Yes -5C (32F) None Yes 110C (230F) 110C (230F) Black Natural W RA Black
Chlorosulphonated PE
W RH Black
W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
2 06103
March 2007
061 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OPTION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION NOM BORE (mm) See Vol 2 See Vol 2
RANGE
ORIENTATION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 20 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B061 SHAFT FOR SEAL (mm) 55 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 061
SECTION PAGE
DATE
2 06104
March 2007
STATUS
CURRENT
DRIVE SELECTION
MEDIUM 100
Viscosity Limits (Stokes)
1000 80
500
50
40
230 212 176
MARK 3 70 MARK 1
0 87 130 174
104
60
MARK 0
PSI
68 0
50
40
30
20
10
0 10.0
Limit for water like products Capacities below this line require verification by Monoflo
PSI
174 130 87 43
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty Speed, no = rpm @ 0PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.ns Slip Corrected Speed (n = np - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials.
FOOD Check customer CIP process if available. Refer to section 2 for CIP APPLICATIONS suitability. SOLIDS HANDLING (Inches) Hard Angular W 0.41 STARTING TORQUE (lbf.ft) Mark 1 110 Mark 3 110 Mark 5 110 Soft and Mark 0 compressible 1.89 184
Published
in formation
o ther
th an
th at
marked
cer tified
is
to
b e
used
as
g uide
only
Temperature ( F)
0
140
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
2 06203
March 2007
062 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OP TION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION NOM BORE (mm) See Vol 2 See Vol 2
RANGE
ORIENTATION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B071 SHAFT FOR SEAL (mm) 65 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 062
SECTION PAGE
DATE
2 06204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
064
2 06401
March 2007
MEDIUM 50 40
230 212
CURRENT
1000 80
500
Viscosity Limits (Stokes)
100
MARK 3 MARK 1
348
140 104
60
MARK 0
PSI
68 0
40
20
Limit for water like products Capacities below this line require verification by Monoflo
PSI
348 290 217 145 72 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.89
413
258
258
258
Published information other than that marked certified is to be used as a guide only
Temperature (F)
0 217
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
2 06403
March 2007
064 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OP TION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STA NDARD BS EN 1092 Section 3.1 PN 40 BS EN 1092 Section 3.1 PN 40 OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf NOM BORE (mm) See Vol 2 See Vol 2
RANGE
SEAL RANGE W COMMENTS BODY SIZE B091 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
2 06404
March 2007
064 CURRENT
DRIVE SELECTION
Published information other than that marked certified is to be used as a guide only
W
071
2 07101
March 2007
CURRENT
MEDIUM 50
1000
500
100
Viscosity Limits (Stokes)
100
80
60
40
20
Limit for water like products Capacities below this line require verification by Monoflo
PSI
87 58 29 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.2
162
74
74
74
Published information other than that marked certified is to be used as a guide only
Temperature (F)
2 07102
March 2007
10000
STARTING TORQUE POWER ADDITIVE
1000
100
10
0.1
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) None Yes -5C (32F) None Yes 110C (230F) 110C (230F) Black Natural W RA Black
Chlorosulphonated PE
W RH Black
W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
2 07103
March 2007
071 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OP TION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION OPTION STANDARD OPTION NOM BORE (mm) See Vol 2 See Vol 2
RANGE
ORIENTATION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B071 SHAFT FOR SEAL (mm) 65 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 071
SECTION PAGE
DATE
2 07104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
072
2 07201
March 2007
CURRENT
MEDIUM 50 30
230 212
1000
500
PSI
0 87 130
140 104
100 MARK 0 80
174
68 0
60
40
20
Limit for water like products Capacities below this line require verification by Monoflo
15.0
PSI
174 130 87
10.0
5.0
43 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.2
332
184
184
184
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Pu blish ed
in formation
o ther
than
that
marked
cer tified
is
to
b e
used
as
g uide
only
2 07203
March 2007
072 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B071 SHAFT FOR SEAL (mm) 65 STANDA RD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 072
SECTION PAGE
DATE
2 07204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
074
2 07401
March 2007
CURRENT
MEDIUM 50 30
230 212
1000
500
PSI
0 217 290
140 104
100 MARK 0 80
348
68 0
60
40
20
Limit for water like products Capacities below this line require verification by Monoflo PSI
348 290
30.0
20.0
217 145
10.0
72 0
100
300
350
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.2
553
442
442
442
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
in formation
o ther
th an
th at
marked
cer tified
is
to
b e
used
as
g uide
only
2 07403
March 2007
074 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes Refer to Mono AVAILABLE Yes BRIDGEBREAKER FIXED SPEED Yes VARIABLE SPEED Yes LARGE AUGER BARESHAFT Yes MONOBLOC Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN SPECIFICATION OPTION Refer to Monoflo Refer to Monoflo INTERNAL DIMENSIONS (mm) See Volume 2 See Volume 2 OPTIONS Refer to Monoflo Refer to Monoflo BODY MATERIAL Cast Iron
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
OPTION
OPTION ANSI B16.5 Class 300 JIS B2210 20 kgf ANSI B16.5 Class 300 JIS B2210 20 kgf
SEAL RANGE W COMMENTS BODY SIZE E121 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 074
SECTION PAGE
DATE
2 07404
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
081
2 08101
March 2007
CURRENT
MEDIUM 50 MARK 5
230 212 176 140
1000
500
Viscosity Limits (Stokes)
100
160
104 68 0
120
87
80
40 Limit for water like products Capacities below this line require verification by Monoflo 0
9.0 6.0
PSI
87 58 87 0
3.0
200
300
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.63
2.44
184
133
133
133
Published information other than that marked certified is to be used as a guide only
Temperature (F)
2 08102
March 2007
10000
VISCOSITY ADDITIVES
STARTING TORQUE POWER ADDITIVE
1000
100 10 1
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes Section 1 No -5C (23F) None Yes -5C (32F) None Yes 110C (230F) 110C (230F) Black Natural W RA Black
Chlorosulphonated PE
W RH Black
W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
081 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICA TION
RANGE
OPTION
OPTION ANSI B16.1 Class 125 JIS B2210 10 kgf ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B071 SHAFT FOR SEAL (mm) 65 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 081
SECTION PAGE
DATE
2 08104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
082
2 08201
March 2007
CURRENT
MEDIUM 50 40
230 212
1000
500
Viscosity Limits (Stokes)
100
130 174
140 104 68 0
80
60
40
20
Limit for water like products Capacities below this line require verification by Monoflo PSI
174 130 87 43 0
200
300
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.63
2.44
369
277
277
277
Published information other than that marked certified is to be used as a guide only
Temperature (F)
140
MARK 3
PSI
0 87
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) Yes. Section 1 No -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RH W RJ W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
information
oth er
th an
th at
marked
cer tified
is
to
be
used
as
gu ide
o nly
082 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B091 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 082
SECTION PAGE
DATE
2 08204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
084
2 08401
March 2007
CURRENT
MEDIUM 50 40
230 212
1000
500
Viscosity Limits (Stokes)
100
174 261
140 104 68 0
348
80
60
40
20
Limit for water like products Capacities below this line require verification by Monoflo
348
30.0 20.0
10.0
72 0
PSI
200
300
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.63
2.44
738
443
443
443
Published information other than that marked certified is to be used as a guide only
Temperature (F)
140
MARK 3
PSI
0
176
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
information
oth er
th an
th at
marked
cer tified
is
to
be
used
as
gu ide
o nly
2 08403
March 2007
084 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes Refer to Mono AVAILABLE Yes BRIDGEBREA KER FIXED SPEED Yes VARIABLE SPEED Yes LARGE AUGER BARESHAFT Yes MONOBLOC Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.5 Class 300 BS EN 1092 Section 3.1 PN 40 JIS B2210 20 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300 JIS B2210 20 kgf
SEAL RANGE W COMMENTS BODY SIZE E121 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 084
SECTION PAGE
DATE
2 08404
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
088
2 08801
March 2007
MEDIUM
CURRENT
1000
100
230 212
PSI
0
348
140 104
100
MARK 0
522
68 0
80
696
60
40
20 Limit for water like products Capacities below this line require verification by Monoflo
696 522 348
0 50.0
PSI
50 Rotor Selection
150
200
250
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.59
1.81
1475
885
885
885
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
W 088
Preliminary
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating. Utilises 2 off E084 stator.
info rmation other than that marked cer tified is to be u sed as a guid e on ly
Pu blished
W 088
Preliminary
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest to the gland section of the pump) DESIGN SPECIFICATION Option Refer to Monoflo Internal Dimensions (mm) 800 x 450 800 x 450 Option Refer to Monoflo
RANGE
Refer to Monoflo
Refer to Monoflo
COMMENTS
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN SPECIFICATION
RANGE
Option
Standard BS1560 Section 3.1 Class 600 BS1560 Section 3.1 Class 600
COMMENTS
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL 100 STANDARD TYPE PG CI Pump Graphited Acrylic/ Glass Yarn SS Pump Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal. Refer to Volume 2 for full gland details.
Pu blished
info rmation
other
than
that
marked
cer tified
is
to
be
u sed
as
guid e
on ly
W
091
2 09101
March 2007
CURRENT
MEDIUM 100
1000
500
Viscosity Limits (Stokes)
230
212
140
120
MARK 0
58
104
87
68
80
40 Limit for water like products Capacities below this line require verification by Monoflo 0
PSI
87 58 29 0
200
250
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.71
2.76
203
148
148
148
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
2 09102
March 2007
10000
VISCOSITY ADDITIVES
1000 100
STARTING TORQUE
POWER ADDITIVE
10 1
0.1 0.01 1
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (32F) 110C (230F) None Yes Black Natural W RA Black Nitrile W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
2 09103
March 2007
091 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B091 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 091
SECTION PAGE
DATE
2 09104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
092
2 09201
March 2007
CURRENT
MEDIUM 100 65
230 212 176 140 104
1000
500
Viscosity Limits (Stokes)
PSI
0
87
MARK 0 120
130
68 0
174
80
40 Limit for water like products Capacities below this line require verification by Monoflo
174
130 87 43 0
PSI
200
250
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.71
2.76
406
369
369
369
Published information other than that marked certified is to be used as a guide only
Temperature (F)
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
information
oth er
th an
th at
marked
cer tified
is
to
be
used
as
gu ide
o nly
2 09203
March 2007
092 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Ye s
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B091 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 092
SECTION PAGE
DATE
2 09204
March 2007
STATUS
CURRENT
DRIVE SELECTION
200 rpm
W
101
2 10101
March 2007
CURRENT
MEDIUM 100
1000
160
MARK 0
58
120
0
87
80
40
Limit for water like products Capacities below this line require verification by Monoflo
PSI
87 58 29 0
200
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.79
3.15
325
258
258
258
Published information other than that marked certified is to be used as a guide only
W 101 CURRENT
VISCOSITY ADDITIVES
STARTING TORQUE
2 10102
March 2007
10000
1000
100
10
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (32F) 110C (230F) None Yes Black Natural W RA Black Nitrile W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
2 10103
March 2007
101 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes
Yes
BRIDGEBREA KER AVAILABLE Yes FIXED SPEED Yes VARIABLE SPEED Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STA NDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 90 end cover BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Can be rotated Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE B091 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 101
SECTION PAGE
DATE
2 10104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
102
2 10201
March 2007
CURRENT
MEDIUM 100 80
1000
174
MARK 0 120
80
40 Limit for water like products Capacities below this line require verification by Monoflo PSI
174 130
87 43 0
200
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.79
3.15
630
479
479
479
Published information other than that marked certified is to be used as a guide only
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RJ Black High Nitrile W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
Published
information
oth er
th an
th at
marked
cer tified
is
to
be
used
as
gu ide
o nly
2 10203
March 2007
102 CURRENT
GENERAL DATA
BUILD OPTIONS RANGE W COMMENTS PUMP BARESHAFT MONOBLOC Yes Refer to Mono AVAILABLE Yes BRIDGEBREA KER FIXED SPEED Yes VARIABLE SPEED Yes LARGE AUGER BARESHAFT Yes MONOBLOC Yes
FLANGE / FITTINGS
INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN
SPECIFICATION
RANGE
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STA NDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.2 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE E121 SHAFT FOR SEAL (mm) 85 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 102
SECTION PAGE
DATE
2 10204
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
104
2 10401
March 2007
MEDIUM
CURRENT
1000
100
80
230
MARK 3 200
PSI
0
MARK 1
261
160 MARK 0
348
104 68 0
120
80
40 Limit for water like products Capacities below this line require verification by Monoflo PSI
348
261 174 87 0
50
150
200
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.79
2.44
1254
959
959
959
Published information other than that marked certified is to be used as a guide only
Temperature (F)
W 104
CURRENT
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RJ Black High Nitrile W RR Black Nitrile
Temperatures are for continuous operating conditions. Utilises two E102 stators. Refer to Section 1 page 7 for derating.
in formation o ther than that marked cer tified is to b e used as a g uide only
Pu blish ed
2 10403
March 2007
104 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 800 x 450 Refer to Monoflo ORIENTATION Vertical OPTION
SPECIFICATION
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.5 Class 300 BS EN 1092 Section 3.1 PN 40 JIS B2210 20 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300 JIS B2210 20 kgf
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
W
121
2 12101
March 2007
CURRENT
MEDIUM 100
1000 340
500
Viscosity Limits (Stokes)
230
212 176
MARK 1
0 43
140 104
72 87
68 0
Limit for water like products Capacities below this line require verification by Monoflo
PSI
87 58 29 0
50
150
200
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.0
3.0
516
443
443
443
Published information other than that marked certified is to be used as a guide only
Temperature (F)
2 12102
March 2007
10000
STARTING TORQUE POWER ADDITIVE
1000
100
10
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (32F) 110C (230F) None Yes Black Natural W RA Black Nitrile W RR
Temperatures are for continuous operating conditions. Refer to Section 1 Page 7 for derating.
Published information other than that marked certified is to be used as a guide only
2 12103
March 2007
121 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 800 x 450 Refer to Monoflo ORIENTATION Vertical OPTION SPECIFICATION INTERNAL DIMENSIONS (mm) 800 x 450 OPTIONS Refer to Monoflo
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W 121
SECTION PAGE
DATE
2 12104
March 2007
STATUS
CURRENT
DRIVE SELECTION
W
122
2 12201
March 2007
CURRENT
PERFORMANCE DATA
500
MEDIUM 100
Abrasion Zones
MARK 1
104 68 0
MARK 0
PSI
Limit for water like products Capacities below this line require verification by Monoflo
PSI
50
150
200
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.0
3.0
1032
590
590
590
Published information other than that marked certified is to be used as a guide only
Temperature (F)
W 122
Preliminary
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS 0C (32F) 70C (158F) None Yes -5C (23F) 110C (230F) None Yes W RA Black Natural W RR Black Nitrile
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
in formation o ther than that marked cer tified is to b e used as a g uide only
Pu blish ed
2 12203
March 2007
122 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 800 x 450 Refer to Monoflo ORIENTATION Vertical OPTION
SPECIFICATION
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
W
124
CURRENT
PERFORMANCE DATA
500
MEDIUM 100
Abrasion Zones
MARK 1
104 68 0
MARK 0
PSI
Limit for water like products Capacities below this line require verification by Monoflo
PSI
50
150
200
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
1.0
3.0
2065
1180
1180
1180
Published information other than that marked certified is to be used as a guide only
Temperature (F)
2 12402
124 CURRENT
MAR 2007
GENERAL DATA
10000
VISCOSITY ADDITIVES
1000
100
10
0.1 0.01 1 2
3 4 5 Correction Factor
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS
W
Published information other than that marked certified is to be used as a guide only
2 12403
March 2007
124 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 1000 x 450 Refer to Monoflo ORIENTATION Vertical OP TION
SPECIFICATION
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
OPTION
STANDARD
OPTION
BS EN 1092 Section 3.2 PN 40 ANSI B16.1 Class 250 BS EN 1092 Section 3.1 PN 40 ANSI B16.5 Class 300
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDA RD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2
OPTIONS
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
W
151
2 15101
March 2007
CURRENT
PERFORMANCE DATA
Abrasion Zones
MEDIUM 100
500
Viscosity Limits (Stokes)
PSI
0 29
230 212
140 104 68 0
500
MARK 0
58 87
400
300
200
100
Limit for water like products Capacities below this line require verification by Monoflo
PSI
87 58 29 0
40 Rotor Selection
120
160
200
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
1.18
4.13
885
664
664
664
Published information other than that marked certified is to be used as a guide only
Temperature (F)
176
W 151
Preliminary
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS
Pu blish ed
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
in formation o ther than that marked cer tified is to b e used as a g uide only
2 15103
March 2007
151 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 800 x 450 Refer to Monoflo ORIENTATION Vertical OP TION
SPECIFICATION
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STANDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
W
161
2 16101
March 2007
CURRENT
PERFORMANCE DATA
500
MEDIUM 100
Abrasion Zones
1000 MARK 1
MARK 3
0 29 58 87
MARK 0 800
600
PSI
400
200 Limit for water like products Capacities below this line require verification by Monoflo 0 50.0 40.0 30.0 20.0 10.0 0
29 0
87 58
PSI
0 Rotor Selection
150
200
n = corrected duty speed, no = rpm @ 0 PSI, np = rpm @ duty press. ns = Slip Speed = np - no, f x ns = Slip Speed Correction = f.n s Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Above data represents tests on water @ 68F using RR and RA stator materials. Check customer CIP process if available. Refer to Section 2 for CIP suitability
1.18
4.13
959
738
738
738
Published information other than that marked certified is to be used as a guide only
Temperature (F)
230 212
W 161
Preliminary
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
STATOR SELECTION GUIDE RANGE Item Material Temperature Minimum Maximum Derating Food Approved COMMENTS
Pu blish ed
Temperatures are for continuous operating conditions. Refer to Section 1 page 7 for derating.
in formation o ther than that marked cer tified is to b e used as a g uide only
2 16103
March 2007
161 CURRENT
GENERAL DATA
FLANGE / FITTINGS INLET (For clarification the INLET is defined as the port nearest the gland section of the pump) DESIGN RANGE BODY MATERIAL Cast Iron W St. Steel COMMENTS Vertical 800 x 450 Refer to Monoflo ORIENTATION Vertical OPTION
SPECIFICATION
FLANGE / FITTINGS
OUTLET (For clarification the OUTLET is defined as the port furthest from the gland section of the pump) DESIGN
SPECIFICATION
RANGE
ORIENTATION
OPTION
STA NDARD
OPTION
Horizontal Horizontal
ANSI B16.1 Class 125 BS EN 1092 Section 3.1 PN 16 JIS B2210 10 kgf Japanese Sewage Spec. BS EN 1092 Section 3.1 PN 16 ANSI B16.5 Class 150 JIS B2210 10 kgf
SEAL RANGE W COMMENTS BODY SIZE E151 SHAFT FOR SEAL (mm) 100 STANDARD TYPE PG CI PUMP Graphited Acrylic / Glass Yarn SS PUMP Lubricated Aramid Yarn PG Refer to Vol 2 OPTIONS MS Single/Double DIN 24960
= diameter. CI = Cast Iron. SS = Stainless Steel. PG = Packed Gland. MS = Mechanical Seal Refer to Volume 2 for full gland details
Published information other than that marked certified is to be used as a guide only
Chapter 1
1. 2. 3. Spares Ordering Procedure Parts Identification Parts Numbering System
3 1
March 2007
When ordering parts you will need to have the following information ready. 1. The full parts code e.g. RA E041 2205. If the parts cannot be identified or the full parts code is unknown then other information will be needed. 2. 3. 4. NOTE The pump type and order number have been inserted on the facsimile nameplate, this nameplate is fixed onto the pump in a prominent position. The actual certified pump parts list was also enclosed within the O&M instructions. This should be used in conjunction with the sectional arrangement drawing when ordering new parts. The pump type CW051AH2A1. The part description Rotor/Stator/Shaft etc. The material required or the rotating parts code.
Published information other than that marked certified is to be used as a guide only
3 1
March 2007
MATERIALS PARTS IDENTIFICATION The items to be ordered can be identified in several ways. Many rotating parts will carry their parts number etched on them. The exact part number for the component used in your pump can be identified from the parts listing, which can be found inside the Operating and Maintenance Instructions booklet which accompanied your pump. An example of which is at the back of this section. If you do not know the description of your part, this again can be found using the Operating and Maintenance Instructions or the relevant section from this manual. For this you would need the typical pump drawing and the drawing reference number page. It is also possible to identify the part if you have the full pump code. Refer to the pump coding information in the relevant section in this manual. An example of how this can be done now follows. Firstly lets look at how the pump coding is drawn up. Example of W Range Coding Sheet follows on next page.
Published information other than that marked certified is to be used as a guide only
3 2
March 2007
W 0 0 0 0 0 0 0 1 1 1 1 3 4 5 6 7 8 9 0 2 5 6 1 2 4 6 8 A B C D H J H D E S L B C 1 2 A 1
PUMP STAGES
PACKED GLAND PUMP DESIGN DESIGN NUMBER STATOR MAT'L ROTATING PARTS TYPICAL BASIC PUMP CODING
'G' - Standard Bloc 'H' - Standard Bareshaft 'C' - Bareshaft - Mono Australia Only C W 0 6 4 C E 'A' - ANSI + Access Ports 'E' - Standard ANSI 'J' - Japan FULL PUMP CODING TO BE STAMPED ON PUMP NAMEPLATE
Published information other than that marked certified is to be used as a guide only
3 3
March 2007
The maximum number of characters in any pump coding can be fifteen. The following pump characters can be described within these limits but not necessary in this order. PUMP BODY MATERIAL General material description of pressure boundary items i.e. suction and delivery parts. PUMP RANGE DESIGNATION Represents the range description. PUMP CAPACITY OR SIZE Represents the pump size with the specified range. NO. OF STAGES Represents the number of complete stages within the rotor/stator element and would be indicated as 1, 2, 4, 6, 8 etc. STATOR MATERIAL Identifies the stator material by using the second letter of any standard resilient stator material code i.e. A for RA. For non-standard resilient/rigid materials 0 to 9 are used. ROTATING PARTS CODE Identifies the material combination code for the main rotating parts in contact with the fluid being pumped. OBLIQUE SYMBOL(/) The oblique symbol separates the basic pump code from the standard variation code.
Published information other than that marked certified is to be used as a guide only
3 4
March 2007
THE STANDARD VARIATION CODE The standard variation code identifies one or more design features that are different from the standard pump build. This code is used to specify features that will be built into the pump to satisfy the customer specification. Each pump coding system is designed to suit the characters for each range and inevitable there is limited consistency across the range of pump systems. The example pump code we will be looking at is CW052AL2A1. The First Position C = Material of construction in this case Cast Iron. The Second Position W = The range. Third, Fourth and Fifth Position 052 = The pump size and no. of stages size five single stage. The Sixth Position A = Build option (dependant on primer mover selected) Seventh Position L = Feed auger type - In this case large auger Eighth Position 2 = The mark number, this would be used if there was a major change in the pumps design.
Published information other than that marked certified is to be used as a guide only
3 5 March2007
Ninth Position A = The stator material From this information received we can identify and order the correct stator. We have the pump range, size and know the stator material i.e. RA. The stator parts code would be RA E051 2205. The 2205 indicating the stator is explained in a later session. * W Range pumps utilise stators from our industrial E Range The ninth position is the second letter of the stator material i.e. RA, RH, RR, RV etc (except when 0 or 9 is used). The Tenth Position 1 = The rotating parts code. With this number we are able to specify the correct parts number for all rotating parts. In this case for the Rotor, Shaft, Pins and Bushes.
On the next page there is an example of the rotating parts code page from the performance data section. We have been given a rotating parts code of the pump coding across the row rotating parts code, till you find 1. You will see that this is for medium abrasive and non corrosive products. Looking down you will see that the shaft would be made from SX (Stainless) and is HCP (Hard Chrome Plated), the rotor is made from BD (Alloy Steel) and is also HCP, this procedure continues for the remaining items, i.e. these two parts would be SX CO61 3220 and BD CO52 2525 If there is a problem with parts identification or parts ordering, contact Monoflo and ask for the sales Office - Spares.
Published information other than that marked certified is to be used as a guide only
3 6
March 2007
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
Published information other than that marked certified is to be used as a guide only
3 7
March 2007
P101 P102 P103 P104 P109 06A 15A 01A 24A P202 P203 P204 08A 10A 65A P211 25A 32A 38A P401 P402 P403 P404 P405 P406 P422 P423 27A 27B 28A 28B 29A 29B 29C 38B 38C 42A 75A 75B P501 P502 P503 P504 P505 P506 P507 P508 P513 P514 P515 P517 P518 P519 P520 P530 P531 P532 20B 20M 20H 23A 23B 59A 62A 62B 95A P601 P602 P603 P604 22A
S114282F W114252F W114052F N114102F N111102F SF E012 0600 PS B061 1560 CD B061 0100 CD E051 2400 K114290F W114050F N114100F CD E081 0800 ZG E081 0800 CD B061 6500 P100132S BD C052 2521 SX C061 3220 MB W052 3830 S110810P S110810P C107602P C107602P T101082P T101082P A114262F A114262F TO C061 2700 TO C061 2700 RR B061 2810 RR B061 2810 TH B061 2900 TH B061 2900 SB B061 2920 SF W052 3843 SF W052 3843 RR B061 4200 SF B0617500 SF B061 7500 P100432S P100832S W113252F W113052F N113102F W113252F W113052F N113102F F114222F W114252F W114052F S145262F W115052F W115252F N115102F A115241F W115052F W113252F ZG E061 2020 ZG C061 2030 ZG W052 2038 MB W052 2308 MB W052 2339 MB C081 5900 MA E052 6200 MB W052 6208 MS W052 9500 K114302F W114302F W114052F N114102F RR E052 2205
STEEL STUD M10 x 40(1D) SNGL.COIL SPR.WASHER M10 STEEL BRIGHT WASHER M10 STEEL HEX.NUT M10 STEEL HEX.NUT M5 NP E RANGE SOG PACK SIZE -100 NP THROWER GUARD BODY-STD C.I. END COVER C.I. BS4504 16/11RF ST.STL.HEX.HD BOLT M10 x 45 ST. STL. BRIGHT WASHER M10 ST.STL.HEX NUT M10 GLAND FOLLOWER-STD C.I. PACKG GLAND PACKING SET 6 RINGS GLAND SELECTION- STD C.I. MAL.IRON TAPER PLUG 1/8" BSP ROTOR - MKO HCP DRIVE SHAFT HCP HELICAL CONV - L. AUGER (0.75M) TORL SEAL RING 0545 - 30 BK NITR TORL SEAL RING 0545 - 30 BK NITR SPIRAL RET. RING S. S.60MM SHFT SPIRAL RET. RING S. S.60MM SHFT TIE - SEALING COVER TIE - SEALING COVER ST.STL.SOC.CAP SCREW M10 x 35 ST.STL.SOC.CAP SCREW M10 x 35 COUPLING ROD BUSH COUPLING ROD BUSH SEALING COVER SEALING COVER COUPLING ROD PIN COUPLING ROD PIN SHAFT PIN S.S. COUPLING END COUPLING END THROWER (NITRILE RUBBER) SLEAVE (ROTOR SHAFT) SLEAVE (ROTOR SHAFT) MAL IRON TAPER PLUG 1/2"BSP MAL IRON TAPER PLUG 1. 1/2"BSP SNGL. COIL SPR.WASHER.M8 STEEL BRIGHT WASHER M8 STEEL HEX NUT M8 SNGL. COIL SPR WASHER M8 STEEL BRIGHT WASHER M8 STEEL HEX NUT M8 ST.HEX.HD.SCREW M10 x25 SNGL. COIL SPR.WASHER.M10 STEEL BRIGHT WASHER M10 STEEL STUD M12 x 35 (1.5D) STEEL BRIGHT WASHER M12 SNGL. COIL SPR WASHER M12 STEEL HEX NUT M12 H.T.STL SOC CAP SCREW M12 x 30 STEEL BRIGHT WASHER M12 SNGL. COIL SPR.WASHER.M8 GASKET GLAND INSPECTION PORT GASKET GASKET - THROAT/FEED CHAMBER THROAT - LARGE AUGER (0.75) FEED CHAMBER INSPECTION FRONT COVER PLATE SUPPORT FOOT SUPPORT FOOT - LARGE AUGER TIE ROD M.S. STL.HEX.HD.BOLT M10 x 50 SNGL.COIL SPR.WASHER M10 STEEL BRIGHT WASHER M10 STEEL HEX NUT M10 STATOR - MTM NITRILE RUBBER
4 4 4 4 1 1 2 1 1 2 2 2 1 1 1 2 1 1 1 1 8 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 4 4 4 4 4 2 2 2 4 4 4 4 10 10 10 1 1 1 1 1 1 1 1 4 4 4 4 4 1
Published information other than that marked certified is to be used as a guide only
3 8
March 2007
MATERIALS PARTS NUMBERING SYSTEM The part numbers are made up of four descriptive fields:1. 2. 3. 4. 1. 2. 3. Material Pump Range and Size Item Classification Number Variation Code The material code will be 2 characters i.e. SF, MM, MB. The pump range and size will consist of three or four characters i.e. LR21, E081, D40. The item classification will consist of two numbers and these numbers indicate the standard component.
i.e. 22 = Stator 25 = Rotor 32 = Shaft etc. (See Appendix A) 4. The last two characters the variation code generally indicates the variance from the standard component.
i.e. 2502 Temperature Rotor Mk III 2520 Rotor H.C.P. (Hard Chrome Plated) Wherever possible the variation codes are standardised between ranges. The format of the part numbers are as the following examples:Material SF SF RR Pump Range and Size E081 D30 LN21 Item Numbers 32 25 22 Classification Code 20 00 00
Published information other than that marked certified is to be used as a guide only
3 9
March 2007
Published information other than that marked certified is to be used as a guide only
3 10
March 2007
MATERIALS MATERIAL CODES Listed below a general list of materials used in the pumps, these are the main materials with high usage and are for a guide only, this is not a complete list and if you have any problems or queries you should contact Monoflo. Description BD CD CF MB MM SA SB SF SO ST SX TH TO TS Alloy Steel Cast Iron Cast Iron Mild Steel Mild Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Tool Steel Tool Steel Tool Steel
Published information other than that marked certified is to be used as a guide only
3 11
March 2007
RA
Grade A
158
RE RH RJ
Ethylene Propylene Rubber (EPR) Chlorosulponated P.E. (CSM) High Nitrile Rubber
RR
230
RV
Fluoroelastomer (FKM)
302
Published information other than that marked certified is to be used as a guide only
Chapter 2
Operating and Maintenance Instructions can be obtained by contacting your Monoflo Representative.
W ALL 2
INDEX
March 2007
SECTION W-1 SECTION W-2 SECTION W-3 SECTION W-4 SECTION W-5 SECTION W-6 SECTION W-7 SECTION W-8 SECTION W-9 SECTION W-10 SECTION W-11 SECTION W-12 SECTION W-13 SECTION W-14
PRE-SELECTION TABLE PUMP CODING TABLE ROTATING PARTS CODING MATERIALS OF CONSTRUCTION ROTOR IDENTIFICATION STATOR IDENTIFICATION BEARING IDENTIFICATION GLAND PACKING DETAILS GLAND SECTION DIMENSIONS FLANGE DIMENSIONS THROAT DETAILS PUMP DIMENSIONS BARESHAFT PUMP WEIGHTS MAXIMUM DIFFERENTIAL PRESSURES
Published
information
other
than
that
marked
certified
is
to
be
used
as
guide
only
3 W1-1
March 2007
ALL CURRENT
946
W161
682
W151
378
W121
215
W122
W124
W101
CAPACITY (gallons/minute) 176
W102 W104
W091
149
W092
W081
125
W082
W071
77
W072
W074
W061
44
W062
W051
22
W052
W054
W041
5
W042
W031
0 0 87
W032
1769
W034
58 522 696
PRESSURE (PSI)
Published information other than that marked certified is to be used as a guide only
PUMP RANGE
W-3 W2-1
March 2007
MODEL
STATUS
ALL CURRE NT
W 0 0 0 0 0 0 0 1 1 1 1 3 4 5 6 7 8 9 0 2 5 6 1 2 4 6 8 A B C D H J H D E S L B C 1 2 A 1
PUMP STAGES
PACKED GLAND PUMP DESIGN DESIGN NUMBER STATOR MAT'L ROTATING PARTS TYPICAL BASIC PUMP CODING
'G' - Standard Bloc 'H' - Standard Bareshaft 'C' - Bareshaft - Mono Australia Only C W 0 6 4 C E 'A' - ANSI + Access Ports 'E' - Standard ANSI 'J' - Japan FULL PUMP CODING TO BE STAMPED ON PUMP NAMEPLATE
Published information other than that marked certified is to be used as a guide only
3 W3-1
March 2007
ALL 2
1
Light Corrosive SF TH TO SF HCP
5
Medium Corrosive SF HCP TH TO SF HCP
BD - Alloy Steel. SF/SX - Stainless Steel. TH/TO - Tool Steel. HCP - Hard Chrome Plate If alternative materials are required please refer to Monoflo Corrosion: Check Suitability of materials for corrosion resistance.
Published information other than that marked certified is to be used as a guide only
3 W4-1
March 2007
ALL 2
MATERIAL CAST IRON CAST IRON STAINLESS STEEL GRAPHITED ACRYLIC / GLASS YARN LUBRICATED ARAMID YARN MILD STEEL STAINLESS STEEL MILD STEEL STAINLESS STEEL CAST IRON MILD STEEL
CODE CD CD ST ZG ZH MB SF MB SF SO CD MA MB SF ST BD SF SF TS MB SF SB SF SF CD ST SF
10A
GLAND PACKING
23A
HOPPER
BSEN10025 BS1449 BSEN10025 BS1449 BS1449 BS1452 BS3100 BSEN10025 BS1449 BS3100 ASTMA322 BS970 BS970 BS4659 BSEN10025 BS970 BS970 BS970 BS970 BS14512 BS3100 BS970
GRADE S275 316S11 OR 316S13 GRADE S275 316S11 OR 316S13 304 GRADE 220 OR 260 GRADE A1 GRADE S275 316S11 OR 316S13 316C16F 4140 (HCP) 316S31 316S31 (HCP) BD3 (HCP) GRADE S275 316S31 431S29 (HCP) 316S31 316S31 (HCP) GRADE 220 OR 260 316C16F 316S31
23B
FEED CHAMBER
24A
END COVER
25A
ROTOR
26A
32A
SHAFT
GLAND SECTION
COUPLING END
Published information other than that marked certified is to be used as a guide only
3 W5-1
March 2007
ALL 2
A B
SINGLE STAGE
MODEL W041 W051 W061 W071 W081 W091 W101 W121 W151 W161 A 11.22 13.66 16.54 19.02 20.91 23.43 26.77 32.16 38.19 50.27 B 9.06 11.50 13.46 16.18 18.07 20.16 23.50 24.96 34.25 46.42 C 1.57 1.97 2.36 2.76 3.11 3.48 4.02 4.80 5.91 5.91 WEIGHT 6.2 11.9 20.5 32.3 43.8 62.7 95.9 165.4 334.4 402.6
TWO STAGE
MODEL W032 W042 W052 W062 W072 W082 W092 W102 W122 A 13.86 19.33 24.45 28.86 33.46 37.37 41.53 48.23 57.24 B 11.85 17.20 21.69 28.86 33.46 37.32 41.54 48.23 53.39 C 0.98 1.57 1.97 2.36 2.76 3.07 3.46 3.98 4.80 WEIGHT 3.1 10.3 20.5 34.5 53.9 75.7 106.3 156.4 310.2
FOUR STAGE
MODEL W034 W044 W054 W064 W074 W084 W104 W124 A 26.54 36.50 45.63 54.53 64.69 70.67 93.86 112.44 B 24.17 33.66 42.64 51.06 60.63 66.61 90.00 108.58 C 0.98 1.57 1.97 2.36 2.76 3.07 3.98 4.80 WEIGHT 6.6 20.5 37.0 64.2 108.5 146.1 352.0 594.0
All dimensions in inches All weights in pounds Note Dimensions and weights are approximate only. They are intended to serve as a guide to component identification where this is in doubt.
Published information other than that marked certified is to be used as a guide only
3 W6-1
March 2007
ALL 2
DIA B
SINGLE STAGE
MODEL W041 W051 W061 W071 W081 W091 W101 W121 W151 W161 A 9.02 11.42 13.66 16.10 17.87 20.04 23.15 27.99 34.21 46.06 B 3.74 4.72 5.71 5.98 7.05 7.76 8.74 10.75 12.76 12.76 WEIGHT 4.4 9.2 16.7 22.7 30.6 48.0 64.7 121.0 198.0 264.0
TWO STAGE
MODEL W032 W042 W052 W062 W072 W082 W092 W102 W122 A 11.34 17.09 21.65 25.94 30.59 33.94 38.23 44.06 53.31 B 2.56 3.74 4.72 5.71 5.98 7.05 7.76 8.74 10.75 WEIGHT 3.3 8.4 18.3 31.9 42.9 58.1 91.1 122.8 298.3
FOUR STAGE
MODEL W034 W044 W054 W064 W074 W084 W104 W124 A 23.11 33.15 42.13 50.55 59.61 66.10 B 2.56 3.74 4.72 5.71 5.98 7.05 WEIGHT 7.7 17.2 35.6 62.0 83.6 113.1
All dimensions in inches All weights in pounds Note Dimensions and weights are approximate only. They are intended to serve as a guide to component identification where this is in doubt.
Published information other than that marked certified is to be used as a guide only
SECTION PAGE DATE W RANGE BEARING IDENTIFICATION Bearing Housing (Where Used)
SPECIFICATION BS3134-1979 (ISO 355) No. 6307 (No. 2RS)
3 W7-1
March 2007
ALL 2
MODEL
W032 W034 W042 W051 W061 W054 W071 W081 W064 W091 W101 W074 W102 W104 W151 W124 W041 W044 W052
P110 P111
40 x 90 x 25.25
P110 P111
No. 31311 (No. 7FB) No. 31313 (No. 7GB) No. 31316 (No. 7GB) No. 31318 (No. 7GB) No. 30322 (No. 2GB) No. 31311 (No. 7GB)
55 x 120 x 31.5
65 x 140 x 36
Published information other than that marked certified is to be used as a guide only
3 W8-1
March 2007
ALL 2
PUMP BODY E012 B041 B061 B071 B091 B/E121 B/E151 E201
NUMBER OF RINGS 5
PACKING SECTION 8 10 10
12.5 12.5 15
DRAWING NUMBER E012 1000 AC1 1000 E081 1000 E101 1000 B091 1000 E121 1000 E151 1000 E201 1000
15 7 18
MODEL W032 W034 W041 W042 W051 W044 W052 W061 W054 W062 W071 W072 W081 W064 W082 W091 W092 W101 W074 W084 W102 W121 W104 W122 W151 W161 W124
Published information other than that marked certified is to be used as a guide only
3 W9-1
March 2007
ALL 2
DIA B
DIA A
DIA C
E F
H APPROX TO OBSTRUCTION
MODEL W032 W034 W041 W042 W044 W052 W061 W054 W062 W071 W072 W081 W064 W082 W091 W092 W101 W074 W084 W102 W121 W104 W122 W151 W161 W124
A 48 65 75
B 32 45 55
C 60 78 91 106
D 44 65 65 82
E 71 100 117
F 86 122 140
G 9 11 11 13
H 18 40 46
90
65
134
153
38
110
85
130
82
160
188
13
35
85 100 160
98 98 118
13 13 17
90 90 90
Published information other than that marked certified is to be used as a guide only
3 W10-1
March 2007
ALL 2
G F
DIA D
PUMP MODEL CW032 CW042 CW051 CW052 CW061 CW062 CW071 CW072 CW081 CW082 CW091 CW092 CW101 CW102 CW121 CW151 CW161 CW034 CW044 CW054 CW064 CW074 CW084 CW104 CW122 CW124 SW032 SW042 SW051 SW052 SW061 SW062 SW071 SW072 SW081 SW082 SW091 SW092 SW101 SW102 SW121 SW122 SW151 SW161 SW034 SW044 SW054 SW064 SW074 SW084 SW104 SW124
FLANGE STD. BSP THREAD TO BS21 BS EN 1092 SECT 3.2 PN16 DIN 2533-16 (CAST IRON) BS EN 1092 SECT 3.1 PN16 (CAST IRON) BS EN 1092 SECT 3.1 PN40 DIN 2545-40 (CAST IRON)
A 65 80 100 125 150 200 250 50 80 100 125 150 200 40 65 80 100 125 150 200 250 50 80 100 125 150 200
B 185 200 220 250 285 340 405 165 200 235 270 300 375 150 185 200 220 250 285 340 405 165 200 235 270 300 375
C No x D E 1 BSP outlet provided 145 4 x 18 122 160 8 x 18 138 180 8 x 18 158 210 8 x 18 188 240 8 x 22 212 295 12 x 22 268 355 125 160 190 220 250 320 110 145 160 180 210 240 295 355 125 160 190 220 250 320 12 x 26 8 x 19 8 x 18 8 x 22 8 x 26 8 x 26 12 x 31 4 x 18 4 x 18 8 x 18 8 x 18 8 x 18 8 x 22 12 x 22 12 x 26 8 x 18 8 x 18 8 x 22 8 x 26 8 x 26 12 x 3 320 102 138 162 188 218 284 88 122 138 158 188 212 268 320 102 138 162 188 218 284
F 20 22 24 26 26 30 26 22 24 24 26 28 37 16 18 20 20 22 22 24 26 19 24 24 26 28 34
G 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
All dimensions in mm
Published information other than that marked certified is to be used as a guide only
3 W10-2
March 2007
ALL 2
G F
DIA D
PUMP MODEL CW032 CW041 CW042 CW051 CW052 CW061 CW062 CW071 CW072 CW081 CW082 CW091 CW092 CW101 CW102 CW121 CW151 CW122 CW161 CW034 CW044 CW054 CW064 CW074 CW084 CW104 CW124 SW032 SW041 SW042 SW051 SW052 SW061 SW062 SW071 SW072 SW081 SW082 SW091 SW092 SW101 SW102 SW121 SW151 SW122 SW161 SW034 SW044 SW054 SW064 SW074 SW084 SW104 SW124
A 80
B 191 229 279 343 406 165 210 254 318 381 381 445 127 191 229 279 343 406 165 210 254 318 381 445
C No x D E 1 NPT outlet provided 152 191 241 298 362 127 168 200 270 330 330 387 98 152 191 241 298 362 127 168 200 270 330 387 4 x 19 8 x 19 8 x 22 8 x 22 12 x 25 8 x 19 8 x 22 8 x 22 12 x 22 12 x 25 12 x 25 16 x 28 4 x 16 4 x 19 8 x 19 8 x 22 8 x 22 12 x 25 4 x 19 8 x 22 8 x 22 12 X 22 12 x 25 16 x 28 106 145 176 246 303 270 324 73 127 157 216 270 324 91 127 157 216 270 324
F 19 24 25 28 30 22 28 32 37 41 41 48 18 25 25 26 29 33 22 28 32 37 41 48
ANSI B16.1 CLASS 250 (CAST IRON) ANSI B16.5 CLASS 300 (CARBON STL.)
2 2 2 2 2 2 2 2 3 3 3 3 3 2 2 2 2 2 2
All dimensions in mm
Published information other than that marked certified is to be used as a guide only
3 W10-3
ALL 2
March 2006
G F
DIA D
C PUMP MODEL CW032 CW041 CW042 CW051 CW052 CW061 CW062 CW071 CW072 CW081 CW082 CW091 CW092 CW101 CW102 CW121 CW122 CW151 CW161 CW104 CW124 CW034 CW044 CW054 CW064 CW074 CW084 SW032 SW041 SW042 SW051 SW052 SW061 SW062 SW071 SW072 SW081 SW082 SW091 SW092 SW101 SW102
SW121 SW151 SW161
A 3
B 7.50 9.00 11.00 13.50 16.00 15 17.5 6.50 8.25 10.00 12.50 15.00 5.00 7.50 9.00 11.00 13.50 16.00 6.50 8.25 10.00 12.50 15.00 17.5
C No x D E 1 NPT outlet provided 6.00 7.50 9.50 11.75 14.25 13 15.25 5.00 6.62 7.88 10.62 13.00 3.88 6.00 7.50 9.50 11.75 14.25 5.00 6.62 7.88 10.62 13.00 15.25 4 x 0.75 8 x 0.75 8 x 0.88 8 x 0.88 12 x 1.00 12 x 1.00 16 x 1.25 8 x 0.62 8 x 0.88 8 x 0.88 12 x 0.88 12 x 1.00 4 x 0.62 4 x 0.75 8 x 0.75 8 x 0.88 8 x 0.88 12 x 1.00 8 x 0.75 8 x 0.75 8 x 0.75 12 x 0.75 12 x 1.00 16 x 1.25 10.62 12.75 4.19 5.69 6.94 9.69 11.94 2.88 5.00 6.19 8.50 10.62 12.75 3.62 5.00 6.19 8.50 10.62 12.75
F 0.75 0.94 1.00 1.12 1.19 1.62 1.89 0.88 1.12 1.25 1.44 1.62 0.69 0.94 0.94 1.00 1.12 1.19 0.88 1.12 1.25 1.44 1.62 1.89
4 6 8
ANSI B16.5 CLASS 150 (CARBON STL.) ANSI B16.5 CLASS 300 (CARBON STL.) ANSI B16.1 CLASS 250 (CAST IRON)
10 8 10 2 3 4 6 8 1.5 3
0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06
4 6 8 10 2 3 4 6 8 10
W ALL 2
3 W11-1
March 2007
B
(x no. of holes)
F
(x no. of holes)
A
13.78 19.69 25.59 25.59 25.59 31.50 31.50 31.50 39.37 39.37
B
9.84 9.84 14.17 14.17 14.17 17.72 17.72 17.72 17.72 17.72
C
16.93 22.83 28.74 28.74 28.74 34.65 34.65 34.65 42.52 42.52
D
12.99 12.99 17.32 17.32 17.32 20.87 20.87 20.87 20.87 20.87
E
0.59 0.59 0.59 0.59 0.59 0.67 0.67 0.67 0.59 0.59
F
3.94x4 4.33x5 5.51x5 5.51x5 5.51x5 5.55x6 5.55x6 5.55x6 5.91x8 5.91x8
G
0.59 0.59 0.63 0.63 0.63 0.59 0.59 0.59 0.59 0.59
H
3.94x3 3.94x3 5.35x3 5.35x3 5.35x3 4.92x4 4.92x4 4.92x4 4.92x5 4.92x5
DIA J J
0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55
A
12.60 12.60 13.78 13.78 19.69 19.69 25.59 25.59 25.59 25.59 25.59 25.59 31.50 31.50
B
6.69 6.69 9.84 9.84 9.84 9.84 14.17 14.17 14.17 14.17 14.17 14.17 17.72 17.72
C
15.75 15.75 16.93 16.93 22.83 22.83 28.74 28.74 28.74 28.74 28.74 28.74 34.65 34.65
D
9.84 9.84 12.99 12.99 12.99 12.99 17.32 17.32 17.32 17.32 17.32 17.32 20.87 20.87
E
0.79 0.79 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.67 0.67
F
3.54x4 3.54x4 3.94x4 3.94x4 4.33x5 4.33x5 5.51x5 5.51x5 5.51x5 5.51x5 5.51x5 5.51x5 5.55x6 5.55x6
G
0.79 0.79 0.59 0.59 0.59 0.59 0.63 0.63 0.63 0.63 0.63 0.63 0.59 0.59
H
4.13x2 4.13x2 3.94x3 3.94x3 3.94x3 3.94x3 5.35x3 5.35x3 5.35x3 5.35x3 5.35x3 5.35x3 4.92x4 4.92x4
J
0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55
Published information other than that marked certified is to be used as a guide only
3 W11-2
March 2007
ALL 2
B
(x no. of holes)
F
(x no. of holes)
B
9.84 9.84 9.84 9.84 14.17 14.17 14.17 14.17 14.17 14.17 17.72 17.72 17.72 17.72 17.72
C
32.68 32.68 32.68 32.68 42.52 42.52 42.52 42.52 42.52 42.52 42.52 42.52 42.52 42.52 42.52
D
12.99 12.99 12.99 12.99 17.32 17.32 17.32 17.32 17.32 17.32 20.87 20.87 20.87 20.87 20.87
E
0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59 0.59
F
6.30x5 6.30x5 6.30x5 6.30x5 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7 5.91x7
G
0.59 0.59 0.59 0.59 0.63 0.63 0.63 0.63 0.63 0.63 0.59 0.59 0.59 0.59 0.59
H
3.94x3 3.94x3 3.94x3 3.94x3 5.35x3 5.35x3 5.35x3 5.35x3 5.35x3 5.35x3 4.92x4 4.92x4 4.92x4 4.92x4 4.92x4
DIA J
J
0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55
Published information other than that marked certified is to be used as a guide only
3 W12-1
March 2007
ALL CURRENT
Pump Model 032 034 041 042 044 051 052 054 061 062 064 071 072 074 081 082 084 091 092 101 102 104* 121 122 124* 151 161 * 2 x 2 stage stators
518
169
374
782
230
490
1005
282
594
1209
339
707
1384
394
802
1552
444
906
523
1054 1054 598 1241 1241
735
1036
3 W12-2
March 2007
ALL 2
N3
N2 Q
N2N T
P2 Q2 U L K MODEL
W032 W034 W041 W042 W044 W051 W052 W054 W061 W062 W064 W071 W072 W074 W081 W082 W084 W091 W092 W101 W102 W121 A 45.51 64.49 52.13 59.96 78.23 62.76 73.19 98.43 72.64 88.54 116.69 80.08 94.57 81.81 101.61 94.76 112.95 97.83 A1 B 40.20 32.80 46.61 56.26 43.90 34.21 42.09 51.77 59.41 70.04 54.53 44.17 54.41 65.00 75.87 91.77 64.41 53.62 65.91 77.95 105.31 92.05 69.49 57.48 83.98 71.97 121.22 106.34 71.26 59.25 90.24 76.97 128.90 114.02 70.16 83.39 101.57 88.35 86.46 73.23 111.69 96.81 82.32 97.28 P1 2.91 2.91 3.94 3.94 3.94 3.94 3.94 5.12 3.94 5.12 5.51 5.51 5.51 5.71 5.51 5.51 6.69 7.87 7.87 7.87 7.87 8.66 P2 2.91 2.91 3.94 3.94 3.94 3.94 3.94 5.12 3.94 5.12 5.51 5.51 5.51 5.71 5.51 5.51 6.69 7.87 7.87 7.87 7.87 8.66 C 13.66 17.87 17.91 17.87 18.82 18.58 18.78 22.56 19.02 22.64 24.65 22.60 22.60 22.60 24.65 24.61 24.61 24.61 C1 7.40 9.65 9.69 9.69 10.63 10.35 10.59 11.97 10.79 12.05 13.27 12.01 12.01 14.88 12.01 13.27 14.88 13.23 13.23 13.23 14.88 14.88 Q1 3.94 3.94 5.12 5.12 5.12 5.12 6.06 6.30 6.06 6.69 7.09 7.09 7.09 7.40 7.09 7.09 8.66 9.45 9.45 9.45 10.24 11.02 D
1 NPT
P1 Q U J
F 1.97 3.15 3.15 3.15 3.15 3.15 3.15 4.33 3.15 4.33 4.45 4.33 4.33 4.33 4.45 4.45 4.45 4.45 G 5.31 8.23 8.23 8.23 8.23 8.23 8.23 10.59 8.23 10.59 10.59 10.59 10.59 10.59 11.38 11.38 11.38 11.38 H 3.78 5.75 5.75 5.75 5.98 5.75 5.98 7.01 5.98 7.01 7.68 7.01 7.01 7.68 7.01 7.68 8.46 7.68 7.68 7.68 8.46 8.46 T 24 35 35 35 35 35 35 50 35 50 55 50 50 50 55 55 55 55 J K 23.31 11.34 23.58 24.37 26.14 9.84 25.91 18.03 27.68 33.39 34.25 12.28 34.13 22.60 35.28 42.36 41.61 14.57 41.73 26.85 43.15 50.83 43.03 17.01 42.91 31.50 46.38 63.54 43.03 18.78 45.08 34.84 47.72 70.24 51.73 20.43 51.54 39.80 55.47 22.52 55.12 44.45 55.20 31.97 U 5/16 3/8 3/8 3/8 1/2 3/8 1/2 5/8 1/2 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8
P U H G
M1 0.24 0.24 0.31 0.31 0.31 0.24 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.39 0.31 0.31 0.39 0.31 0.31 0.31 0.31 0.31 W 6.69 6.69 9.84 9.84 9.84 9.84 9.84 9.84 14.17 14.17 14.17 14.17 14.17 14.17 14.17 14.17 14.17 17.72 17.72 17.72 17.72 17.72 M2 0.24 0.24 0.31 0.31 0.31 0.24 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.87 0.31 0.31 0.39 0.31 0.31 0.31 0.31 0.31 X
2 3 3 3 3 3 4 4 4 6 6 6 6 6 6 8 8 8 8 8 10 Q2 3.94 3.94 5.12 5.12 5.12 5.12 6.06 6.30 6.06 6.69 7.09 7.09 7.09 7.40 7.09 7.09 8.66 9.45 9.45 9.45 10.24 11.02
E 1.97 3.86 3.86 3.86 3.86 3.86 3.86 5.08 3.86 5.08 5.35 5.08 5.08 5.08 5.35 5.35 5.35 5.35
L1 1.57 1.57 1.57 1.77 1.77 1.57 1.97 1.77 2.36 2.36 2.17 2.44 2.44 3.15 2.44 2.44 3.15 2.76 2.76 2.76 2.76 3.54
L2 1.57 1.57 1.57 1.57 1.77 1.57 2.36 1.77 2.36 2.36 2.17 2.44 2.44 3.54 2.44 2.76 3.54 2.76 2.76 2.76 2.76 3.94
M 0.59 0.63 0.63 0.63 0.71 0.71 0.71 0.91 0.71 0.91 0.87 0.91 0.91 1.18 0.91 0.87 1.18 0.87 0.87 0.87 1.18 1.18
N 1.10 1.26 1.26 1.26 1.50 1.26 1.50 1.73 1.50 1.73 1.85 1.73 1.73 2.32 1.73 1.85 2.32 1.85 1.85 1.85 2.32 2.32 X1
N1 1.54 3.15 3.15 3.15 2.87 3.15 2.87 3.39 2.87 3.39 3.78 3.39 3.39 3.94 3.39 3.78 3.94 3.78 3.78 3.78 3.94 3.94 X2
N2 23.31 23.86 26.26 26.06 28.11 34.45 34.17 36.06 41.54 42.05 43.90 43.19 43.19 47.36 43.19 45.59 48.35 51.89 51.89 56.65 55.63 55.04 X3
N3 11.34 24.37 9.84 18.07 33.39 12.28 22.60 42.36 14.57 26.85 50.83 17.01 31.50 64.37 18.78 34.69 71.06 20.43 39.80 18.74 44.45 33.46 X4
MODEL
W032 W034 W041 W042 W044 W051 W052 W054 W061 W062 W064 W071 W072 W074 W081 W082 W084 W091 W092 W101 W102 W121
P 3.94 4.33 4.33 4.33 4.72 4.33 4.72 5.91 4.72 5.91 6.69 5.91 5.91 9.45 5.91 6.69 9.45 6.69 6.69 6.69 9.45 9.45
Q 4.72 5.51 5.51 5.51 6.30 5.51 6.30 7.09 6.30 7.09 7.87 7.09 7.09 11.02 7.09 7.87 11.02 7.87 7.87 7.87 11.02 11.02
R 3.35 4.41 4.41 4.41 4.92 4.41 4.92 5.91 4.92 5.91 6.30 5.91 5.91 8.86 5.91 6.30 8.86 6.30 6.30 6.30 8.86 8.86
S 7.28 8.35 9.13 9.13 9.65 9.72 10.24 11.22 11.22 12.20 12.60 12.99 12.99 15.94 12.99 13.39 15.94 14.17 14.17 14.17 15.94 17.72
S1
16.22 16.73 17.13 18.11 20.28 20.67 20.67 23.62 20.67 24.21 22.64 25.79
U1 5/16 5/16 3/8 3/8 1/2 3/8 1/2 1/2 1/2 1/2 5/8 5/8 5/8 3/4 5/8 5/8 3/4 5/8 5/8 5/8 3/4 3/4
U2 5/16 5/16 3/8 3/8 1/2 3/8 1/2 1/2 1/2 1/2 5/8 5/8 5/8 3/4 5/8 5/8 3/4 5/8 5/8 5/8 3/4 3/4
V 12.60 12.60 13.78 13.78 13.78 19.69 19.69 19.69 25.59 25.59 25.59 25.59 25.59 25.59 25.59 25.59 25.59 31.50 31.50 31.50 31.50 31.50
21.57 21.57 27.48 27.48 33.86 33.86 33.86 33.86 33.86 33.86 39.76 39.76
18.54 22.80 22.80 22.80 23.82 23.82 23.82 23.82 23.82 23.82 23.82 23.82
4.53 4.53 4.53 4.53 5.31 5.31 5.31 5.31 5.31 5.31 5.71 5.71
16.50 16.50 16.50 16.50 17.13 17.13 17.13 17.13 17.13 17.13 18.03 18.03
4.57 4.57 4.57 4.57 4.57 4.57 4.57 4.57 4.57 4.57 18.03 18.03
T = Shaft Diameter
NOTE 1. All dimensions in inches except 'T' (in millimetres) and . for guidance only. For full certified draw ings refer to Monoflo. 2. Shaft diameters are to BS 4506 : 1970 and keyways to BS 4235 : 1982 Part 1 ISO 4773.
3 W12-3
March 2007
ALL 2
P2 U2
Q2 U1 K
P1 L1
Q1
P U L H L G
L2
MODEL
W074 W084 W102 W121 W151 W161
D 6 8 8 10 10 10
133.66 106.34 27.32 141.34 114.02 27.32 124.13 96.81 27.32 109.61 82.32 27.32 132.20 98.74 33.46 144.06 110.59 33.46
47.20 63.54 48.19 70.24 55.59 44.45 55.67 31.97 53.35 55.59 53.35 67.44
N2
N3
47.36 64.37 48.35 71.06 55.63 44.45 55.04 33.46 53.54 56.18 53.54 68.03
MODEL
W074 W084 W102 W121 W151 W161
Q 11.02 11.02
Q1 7.40
Q2 7.40
T 70 70 70 70 75 75
X1
X3 17.13 17.13
X4 4.57
8.66 8.66 11.02 10.24 10.24 8.66 11.02 11.02 11.02 10.63 12.99 18.70 13.39 10.63 12.99 18.70 13.39
25.59 14.17 33.86 23.82 25.59 14.17 33.86 23.82 31.50 17.72 39.76 23.82 31.50 17.72 39.37 17.72 39.37 17.72
1. All dimensions in inches except 'T' (in millimetres) and . for guidance only. For full certified drawings refer to Monoflo. 2. Shaft diameters are to BS 4506 : 1970 and keyways to BS 4235 : 1982 Part 1 ISO 4773.
Published information other than that marked certified is to be used as a guide only
SECTION PAGE DATE W RANGE LARGE AUGER PUMP DIMENSIONS BLOC VERSIONS
A A1 B VxW C1 C
3 W12-4
March 2007
ALL 2
E S R F D M2 M1 M
N3
N2
N1 N
P2 U2 L2
Q2 U1 K
P1 Q1 L1 J
P U H G
MODEL W042 W044 W052 W054 W062 W064 W072 W074 W082 W084 W092 W102 MODEL W042 W044 W052 W054 W062 W064 W072 W074 W082 W084 W092 W102
A1 64.29 82.05 70.91 94.02 87.20 115.08 94.72 131.97 112.80 101.42 139.09 120.20 108.82 121.93 N 1.26 1.50 1.50 1.73 1.73 1.85 1.89 2.32 2.01 2.32 2.01 2.40 N1 3.15 2.87 2.87 3.39 3.39 3.78 3.39 3.94 3.78 3.94 3.78 3.94
B 57.56 75.08 63.94 85.98 79.17 105.94 86.69 121.61 92.28 128.66 99.65 111.50 N2 30.59 30.83 30.43 31.22 40.59 41.38 40.55 41.77 41.18 41.85 41.02 41.65
C1 6.73 6.97 6.97 8.03 8.03 9.13 8.03 10.35 9.13 10.43 9.17 10.43
D 3 3 3 4 4 6 6 6 6 8 8 8 P1 7.09 7.09 8.27 8.27 9.84 9.84 11.22 11.22 13.78 13.78 15.35 16.73
H 5.75 5.98 5.98 7.01 7.01 7.68 7.17 8.46 7.99 8.46 7.99 8.74 Q2 5.12 5.12 6.06 6.30 6.69 7.09 7.09 7.40 7.48 8.66 9.45 10.24
J 30.51 30.51 30.51 30.55 40.39 40.83 40.39 41.06 40.67 41.14 40.71 41.14 R 4.41 4.92 4.92 5.91 5.91 6.30 6.89 8.86 8.86 8.86 8.86 9.84
K 25.87 42.68 32.24 53.39 37.56 63.11 44.88 79.88 50.55 86.93 56.73 68.58 S 11.10 11.61 12.20 13.19 14.76 15.55 5.71 18.31 19.88 19.88 19.88 21.65
L1 1.57 1.77 2.36 1.77 2.36 2.17 2.44 3.15 3.15 3.15 2.76 2.76 U 3/8 1/2 1/2 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8
L2 1.57 1.77 2.36 1.77 2.36 2.17 2.44 3.54 3.15 3.54 2.76 2.76 U1 3/8 1/2 1/2 1/2 1/2 5/8 5/8 3/4 3/4 3/4 5/8 3/4
M 0.63 0.71 0.71 0.91 0.91 0.87 0.91 1.18 2.56 1.18 2.56 0.98 U2 3/8 1/2 1/2 1/2 1/2 5/8 5/8 3/4 3/4 3/4 5/8 3/4
M1 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.39 0.39 0.39 0.31 0.31 V 29.53 29.53 29.53 29.53 39.37 39.37 39.37 39.37 39.37 39.37 39.37 39.37
M2 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.87 0.39 0.87 0.31 0.31 W 9.84 9.84 9.84 9.84 14.17 14.17 14.17 14.17 14.17 14.17 17.72 17.72
N3 P 25.87 4.33 42.68 4.72 32.24 4.72 53.39 5.91 37.56 5.91 63.23 6.69 44.88 9.06 80.71 9.45 50.55 9.45 87.76 9.06 56.73 9.45 68.58 12.60
P2 3.94 3.94 3.94 5.12 5.12 5.51 5.51 5.71 5.51 6.69 7.87 7.87
Q 5.51 6.30 6.30 7.09 7.09 7.87 10.63 11.02 11.02 11.02 11.02 14.17
Q1 8.27 8.27 9.45 9.45 11.42 11.42 13.19 13.19 15.75 15.75 16.93 18.70
T 35 35 35 50 50 55 50 55 55
1. All dimensions in inches except 'T' (in millimetres) and . for guidance only For full certified drawings refer to Monoflo. 2. Shaft diameters are to BS 4506 : 1970 and keyways to BS 4235 : 1982 Part 1 ISO 4773.
Published information other than that marked certified is to be used as a guide only
SECTION PAGE DATE W RANGE LARGE AUGER PUMP DIMENSIONS BARESHAFT VERSIONS
A B VxW
3 W12-5
March 2007
ALL 2
E S D R M2 M1 M F
N3
N2
N1 N T
P2 U2 L2
Q2 U1 K
P1 L1
Q1
P U L H L G
D 6 8 8 10 10 10
T 70 70 70 75 75 75
1. All dimensions in inches except 'T' (in millimetres) and for gui dance only For full certified drawings refer to Monoflo. 2. Shaft diameters are to BS 4506 : 1970 and keyways to BS 4235 : 1982 Part 1 ISO 4773.
Published information other than that marked certified is to be used as a guide only
SECTION PAGE DATE W RANGE LARGE AUGER PUMP DIMENSIONS BARESHAFT VERSIONS
3 W12-6
March 2007
ALL 2
MODEL A B C W104 187.99 35.08 152.91 W124 214.41 41.69 172.72 MODEL N1 W104 9.25 W124 9.06 T = Shaft Diameter NOTE N2 53.58 63.98
D 8 10
E 7.09 10.00
F 5.91 8.46
J 53.39 52.76
L 2.76 3.54
M2 0.87 0.91
M3 0.87 0.91
N 1.97 3.43
1. All dimensions in inches except 'T' (in millimetres) and for guidance only. For full certified drawings refer to Monoflo. 2. Shaft diameters are to BS 4506 : 1970 and keyways to BS 4235 : 1982 Part 1 ISO 4773.
Published information other than that marked certified is to be used as a guide only
W ALL
3 W13-1
March 2007
70 97
143 119 119 169 165 187 282 246 310 458 306 367
629
96 211 264
Refer to Monoflo
240
290
Refer to Monoflo
187
233
Refer to Monoflo
213 262
Refer to Monoflo
290
385
Refer to Monoflo
319
244
271 376
Refer to Monoflo
436
Refer to Monoflo
330
Refer to Monoflo
460 609
Refer to Monoflo
508 675
Refer to Monoflo
396 535
Refer to Monoflo
484 598
Refer to Monoflo
354 418
702
517 788
Refer to Monoflo
546 860
Refer to Monoflo
486 770
Refer to Monoflo
535 814
Refer to Monoflo
392
552 838
647 931
Refer to Monoflo
713 1003
Refer to Monoflo
664 970
Refer to Monoflo
728 990
Refer to Monoflo
550
700
858
Refer to Monoflo
924
Refer to Monoflo
772
Refer to Monoflo
834
Refer to Monoflo
631
884
1043
Refer to Monoflo
1115
Refer to Monoflo
1100
Refer to Monoflo
1144
Refer to Monoflo Refer to Monoflo Refer to Monoflo Refer to Monoflo Refer to Monoflo Refer to Monoflo
902
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
W
ALL
W14-1
March 2007
VOLUME
W RANGE-MAXIMUM DIFFERENTIAL & DISCHARGE PRESSURES FOR BRITISH STANDARD/ANSI PORT FITTINGS FOR STANDARD BUILD AND LARGE AUGER AS SHOWN FOR EACH PUMP MODEL AND SIZE
MAX. DIFFERENTIAL PRESSURE - BAR SOG 1 2 4 6 8 87 87 87 87 87 87 87 87 87 87 87 174 174 174 174 174 174 174 174 174 348 348 348 348 348 348 348 MAX. DISCHARGE PRESSURES - BAR SOG 1 2 4 6 8 116 116 116 116 116 116 116 116 116 116 116 203 203 203 203 203 203 203 203 203 377 377 377 377 377 377 377
W RANGE-MAXIMUM DIFFERENTIAL & DISCHARGE PRESSURES FOR JIS PORT FITTINGS FOR STANDARD BUILD AND LARGE AUGER AS SHOWN FOR EACH PUMP MODEL AND SIZE
MAX. DIFFERENTIAL PRESSURE - BAR SOG 1 2 4 6 8
87 87 87 87 87 87 87 87 87 87 87
MAX. DISCHARGE PRESSURES - BAR SOG 1 2 4 6 8 116 116 116 116 116 116 116 116 116 116 116 174 174 174 174 174 174 174 174 174 319 319 319 319 319 319 319
NOTE 1) Figures shown are based on temperatures of 68F. If operating temperatures are excessive (above 122F) contact Monoflo Ltd to confirm pressure ratings. 2) For the optional port fittings, contact Monoflo to confirm maximum pressure ratings when high temperatures are experienced. 3) For Bridge Breaker models, reduce discharge pressures by 14.5 PSI.
Published information other than that marked certified is to be used as a guide only
ML Range Pumps
A pin-joint pump available in bare shaft configurations
ML Frame
Typical Applications
A range of pumps designed to be directly interchangeable with traditional pin joint style pumps.
Sludges and lime slurry Mineral processing Pressure up to 225 psi Industrial chemicals, detergents, pastes and gels Temperature 14oF up to 230oF Crude oil, waste oil, oily/water separations Fruit slurries, sauces, starches Coating slurry, starch and clays Mine water Capacity
up to 380 gpm
Easy maintenance Materials of construction Low running speeds Gentle pumping action Up to 28ft suction lift High pressure / long haul pumping Versatile
Simple pin type universal joint drive assembly for easy on-site maintenance. Available in cast iron or stainless steel housings, with a choice of rotor and stator materials to suit individual applications e.g. tool steel rotor or natural rubber stator. Reduced wear for a longer working pump life which extends the periods between routine maintenance. Think of the savings that could be realized on abrasive applications. Minimizes shear and crush damage to the pumped product, whilst maintaining a steady flow when pumping products with a high solids content. Deep sumps can be easily emptied without the use of submersible equipment. Can offer considerable project cost savings by utilizing small bore pipework and eliminating the need for a series of pumps, when pumping over long distances or with high head requirements. Can be run in either direction.
Performance Data
380 1ML10H 255 1ML12 140 1ML10
CAPACITY GPM
2ML10H 2ML12 2ML10 2ML8 2ML6 2ML4 2ML3 2ML2 60 75 120 3ML2 3ML12 3ML10 3ML8 3ML6 3ML4 3ML3
Dimensions
MODEL 1ML2 2ML2 3ML2 1ML3 2ML3 3ML3 1ML4 2ML4 3ML4 1ML6 2ML6 3ML6 1ML8 2ML8 3ML8 1ML10 2ML10 3ML10 1ML10H 2ML10H 1ML12 2ML12 3ML12 1ML12H 2ML12H A 17 201/2 241/16 22 /4
1
B 75/16 10 147/16 10 157/16 203/4 13 201/4 27 177/16 287/16 391/16 203/16 32 45 21 321/4 42 271/4 42 31 461/2 62 383/4 62
C 4 4 4 5 5 5 7 7 7 8 8 8 111/2 111/2 111/2 111/2 111/2 111/2 111/2 111/2 141/2 141/2 141/2 141/2 141/2
D 31/4 31/4 31/ 4 4 4 51/2 51/2 51/2 61/4 61/4 61/4 8 8 8 93/4 93/4 93/4 93/4 93/4 121/2 121/2 121/2 121/2 121/
G 81/2 101/2 12 11 /2
1
I 41/4 41/4 41/4 5 5 5 7 7 7 71/2 71/2 71/2 9 9 9 11 11 11 11 11 131/2 131/2 131/2 131/2 131/2
J 11/2 11/2 11/2 2 2 2 3 3 3 43/8 43/8 43/8 49/16 49/16 49/16 53/8 53/8 53/8 53/8 53/8 6 6 6 6 6
Suction Discharge 1 1 1 1 /2
1 3 3 3
A C
/4 /4 /4
1 /4
1
281/16 33 30 37 441/4 39 493/4 603/16 46 583/8 7013/16 53 631/2 73 581/2 73 70 851/2 101 773/4 101
75/16 75/16 9 9 9 111/4 111/4 111/4 14 14 14 1611/16 1611/16 1611/16 1611/16 1611/16 21 21 21 21 21
9 113/16 71/4 8 141/2 101/15 153/4 1313/16 93/4 17 129/16 9 141/2 123/8 15 123/8 141/2 12 14 173/4 14
511/16 511/16 7 7 7 89/16 89/16 89/16 91/4 91/4 91/4 131/2 131/2 131/2 131/2 131/2 18 18 18 18 18
B
SUCTION PORT DELIVERY PORT
I J
All dimensions in inches and for guidance only. Flanges to ANSI B16.1, B16.5 and NPT pipe thread.
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-ML/R1 Monoflo is a registered trademark of Mono Pumps Ltd.
ML ALL CURRENT
1 1 MAY 2008
SELECTION PROCEDURE
PUMP SIZING 1 From the pre-selection table (page 5) select the pump model which initially meets the required capacity / pressure criteria. (Refer to NOTES on page 4) 2 Referring to the performance data in sections 2 & 3 if particle size is a factor then refer to the table labelled SOLIDS HANDLING (inches) on the performance graph to verify the pumps suitability. 3 If variable speed is required then select at maximum capacity. 4 On the y-axis (Capacity) identify the required flow then move horizontally until intersection at the required differential pressure.(see 5). 5 Slip Correction for Viscosity a) If Viscosity is equal to or greater than six (6) stokes then select on the zero PSI pressure line to determine the pump speed required for the duty. From the point of intersection on the curve move vertically down to the x-axis labelled Speed to obtain the required RPM. b) If the viscosity is less than six (6) stokes then the following procedure applies:Use the method given here as Figs. 1 and 2 to estimate Slip and calculate the required pump speed. Slip Correction for Viscosity n = np or n = np - f.ns where n = corrected duty speed no = rpm at zero PSI for duty flow rate (from water performance curves) np = rpm at duty pressure for duty flow rate (from water performance curves (Fig 1)) np-no = Slip speed = ns From viscous slip curve (Fig 2) read slip factor f f x ns = slip speed correction = f.ns Corrected Speed for Duty n = np - f.ns
SLIP FACTOR (f)
Example
176
PERFORMANCE CURVES BASED ON WATER AT 68F
CAPACITY (GPM)
132
0 PSI 60 PSI
88
44 no
np
100
200
300
400
500
SPEED RPM
Fig 1 Duty 88gpm, 60 PSI 100 centistokes (viscosity in pump) Corrected Duty Speed n = np - [ (np - no) f ] n = 410 - [ (410-300) x .78 ] = 324 rpm or n = np - f.ns n = 410 - 85.5 = 324 rpm
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Fig 2 Note: There is no slip correction necessary for water or product with a viscosity of one (1) centistoke.
Published information other than that marked certified is to be used as a guide only
ML ALL CURRENT
1 2 MAY 2008
SELECTION PROCEDURE
6 When RPM is established identify: a) Maximum viscosity as indicated at the top of the performance curve labelled Viscosity Limits. Refer to page 3, Tolerance guidelines - Viscosity Limits. b) Abrasion capability as indicated at the top of the performance curve labelled Abrasion zone. Refer to page 3, Tolerance guidelines - Abrasion zone. If any of the parameters in steps 1 to 6 (b) do not meet the required criteria then re-select from (1) above with the next largest pump size. c) Rotor selection against temperature as indicated in the shaded area of the performance curve for the duty speed identified. Refer to Tolerance guidelines - Rotor selection. d) Absorbed power which is read on the y-axis (Absorbed power) at the differential pressure intersection point (BHP). If the product is viscous then note also the absorbed power on the zero pressure line (FHP) for use later in calculation. 7 If the pump meets the above criteria go to the PUMP CONFIRMATION SECTION. If no pump can be identified then please contact Monoflo for assistance. PUMP CONFIRMATION Having determined the pump size the following steps are necessary: 1 Read the NPSH required from the pump curve at the duty flowrate. Check that the N.P.S.H. required is less than N.P.S.H. available. 2 Note the starting torque required on the performance curve in the table labelled STARTING TORQUE against the selected rotor. 3 If the product is viscous obtain both Starting Torque (f T) and Power Additive (f FHP) factors from the Viscosity Curve graph read at the known viscosity in Stokes. 4 Confirm stator suitability for the product. (Refer to page 3, Tolerance guidelines - Stator selection) 5 Confirm material compatibility and availability for the pump chosen. 6 Select mechanical seal (standard) or packed gland as required. Information obtained from the PUMP DRIVE CONFIRMATION section will be used to determine the required drive. 1 If product is water like, then the absorbed power (BHP) will be as obtained in the PUMP SIZING section, step 6, item (d). Go to step 4. 2 Multiplying the pump starting torque by the starting torque factor obtained in the PUMP CONFIRMATION section, item 3 will give you the starting torque required for the given viscosity. (ie T(lb-ft) x fT = Starting torque at viscosity).(Refer to section DRIVE, items 5 and 6) 3 To obtain the power absorbed at the known viscosity then the full viscous calculation is: Viscous Brake Horsepower (V BHP) = Viscous frictional H.P. + W.H.P. a) Viscous Frictional Horsepower FHP x f FHP. FHP as identified in Pump Sizing section step 6, item (d) (zero PSI pressure). f FHP factor as identified in Pump Confirmation section step 3. Multiply FHP by correction factor f FHP to give frictional horsepower when handling the viscous product. b) Water Horsepower (WHP) is BHP - FHP BHP as identified in Pump Sizing section step 6, item (d) (at duty pressure). FHP as identified in Pump Sizing section step 6, item (d) (at zero PSI pressure). WHP is BHP - FHP c) Add viscous frictional horsepower to water horsepower to obtain BHP absorbed when handling a viscous product i.e. a + b.
4 Determine the motor input power required by allowing for the efficiency of the drive arrangement as follows: Efficiency % Drive Arrangement D.C. to a synchronous speed motor 100 D.C. to a fixed speed geared motor 92 D.C. to a variable speed geared motor 80 (D.C. = Direct Coupled) Therefore input power = BHP (or vBHP) divided by the efficiency.(ie. Input power required for a close coupled CB pump with a direct coupled fixed speed geared motor = BHP (or vBHP) / 0.92)
ML ALL CURRENT
1 3 MAY 2008
SELECTION PROCEDURE
5 Starting torque capabilities will be affected by the type of drive selected and method of starting. Generally motors wired for D.O.L. start on a 3 phase supply will provide 200% FLT (Full Load Torque). Motors wired for Star/Delta start on a 3 phase supply typically provide 50-70% FLT. Single phase motors (capacitor start) typically provide 200% FLT. In all cases reference should be made to the motor manufacturers performance tables. D.O.L. is the preferred method of starting a PC pump. 6 If starting is via an inverter type of drive then 125% FLT availability only is assumed. The correct matching of drive motor/inverter/pump is a specialised skill. Breakout torque and continuous slow running can cause problems. Always refer an inverter application to a specialist drive company, ensuring that they are aware of the full duty parameters to enable them to select the appropriate drive package. 7 Starting with a soft starter should be referred to the manufacturers specification, but typically starting torque will be 150% FLT. 8 Care should be taken when selecting other types of drives to ensure sufficient starting torque is available, i.e. single phase, hydraulic drives, air motors, engines etc. If in doubt refer to Monoflo. TOLERANCE GUIDELINES Rotor Selection Consider maximum fluid temperature, ambient temperature, operating speed and duration of running. All these factors affect stator temperature, in borderline cases select the higher temperature rotor. Fixed Speed If selection falls exactly between rotor types then select the higher temperature rotor. Variable Speed For variable speed drives select the rotor at maximum speed and maximum temperature. Stator Selection Performance curves based on Buna and Natural stator materials.
Stator Options
Code CR CB CQ CF D escrip tio n N atural R ubber EPDM N itrile R ubber F luoroelastom er M ax T em p F 158 266 230 300
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
ML ALL CURRENT
1 4 MAY 2008
STATUS
SELECTION PROCEDURE
NOTES Flow Rate The expected accuracy of progressing cavity pumps is 10% of pump maximum flowrate as shown by the Product Manual Curves. If specific duty points must be achieved ensure that Monoflo are aware of this. Pressure has a proportional effect on wear therefore increasing the number of stages at constant pressure will significantly improve component life. PUMP ROTATION (DOG/SOG) The pump rotation is normally assumed clockwise (when looking on the pump drive shaft end) such that SOG (Suction-On-Gland) flow conditions prevail (ie, product enters at the suction chamber and leaves at the discharge chamber). PRESSURE LIMITATIONS The construction of each different range of pumps will result in maximum discharge pressures and maximum differential pressures that may differ depending upon the specific model, direction of rotation and port fittings. It is therefore important to check that both the differential pressure plus the inlet pressure do not exceed the maximum discharge pressure for the pump selected.
MAX DIFFERENTIAL PRESSURE - PSI SOG DOG 2 3 1 2 180 270 30 30 MAX DISCHARGE PRESSURE - PSI SOG DOG 2 3 1 2 210 300 30 30
TEMPERATURE LIMITATIONS Temperature limitations are dependant on material combinations used. If duty temperatures are outside the limits shown for a particular combination please contact Monoflo for guidance. SPEED LIMITATIONS If speeds below 50rpm are required then please contact Monoflo for assistance.
1 90
3 30
1 120
3 30
NOTE: 1. Figures shown are based on temperatures of 68OF 2. SOG: Suction on Gland DOG: Delivery on Gland 3: For optional part fittings contact Monoflo to confirm maximum pressure ratings when high temperatures are experienced.
Published information other than that marked certified is to be used as a guide only
ML
1 5
ALL CURRENT
MAY 2008
252
TWO STAGE
108 1ML10 80 1ML08 CAPACITY GPM 44.5 1ML06 20 1ML04 8 1ML03 2.875 1ML02 0 0 90 180 270 2ML02 3ML02 2ML03 2ML03 2ML04 3ML04 2ML06 3ML06 2ML08 3ML08 2ML10 3ML10
Published information other than that marked certified is to be used as a guide only
ML ALL CURRENT
1 6 NOV 2008
Description 1 1 2 3 M 2
Pump Code 3 4 5 6
Type Designation
10
11
0 0 2
0.26 USG/100 rpm 0.26 USG/100 rpm 0.86 Maximum Pump Capacity at Maximum Speed & Zero Pressure 2.02 USG/100 rpm 5.2 USG/100 rpm 11.7 USG/100 rpm 18.8 USG/100 rpm 43.5 USG/100 rpm Casting Materials Rotating Parts Code Cast Iron 316 Stainless Steel Plated Alloy Steel 316 Stainless Steel EPDM Stator Material Fluroelstomer Nitrile Natural Rubber Standard Parts Variations Standard Mk1 Rotor, Packed Gland Example: 1 M L -
2 C S D S B F Q R A A A A A A
Do not modify a pump with any variations without first finding out if your pump and the new variation is compatible. Note: For Standard Part Variations other than AAA consult Monoflo.
Published information other than that marked certified is to be used as a guide only
ML ALL CURRENT
1 7 MAY 2008
10000
1000
Starting Torque
Power Additive
100
10
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
ML
1 8
ALL CURRENT
MAY 2008
CR Black Natural
CQ Nitrile
14F (-10C) 41F (5C) 23F (-5C) 158F (70C) 266F (130C) 230F (110C) None None None Yes Yes Yes Temperatures are for continuous operating conditions
CV Refer to Speed/Pressure derate graph for limitations. The power absorbed must be increased by a factor of 1.2. Applications above (88F) 50C Should be refered back to Monoflo.
SPEED / PRESSURE DERATE WHEN USING CF STATORS (UP TO 50oC) (880F) (Moulded to metal stators only)
100%
NOT SUITABLE
75%
Rated Speed
50%
25%
ML
1ML02 2.875 90 1200 GPM PSI RPM
ML 1ML02 CURRENT
2 1 MAY 2008
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI 0 30
1.5
60
0.5
90
0 0.3
PSI 90 60 30 0
55 Durometer
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI
1.5
0 30
0.5
60
200
400
800
1000
1200
Temperature (F)
225 200
Temperature (F)
70 Durometer
225 200
ML 1ML02 CURRENT
2 2 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.08
0.31
10 1 0.1 0.01
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Published information other than that marked certified is to be used as a guide only
ML
2ML02 2.875 180 1200 GPM PSI RPM
ML 2ML02 CURRENT
2 3 MAY 2008
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI 0 60
1.5
120
0.5
180
0 0.6
55 Durometer
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI
1.5
0 60
0.5
120
200
400
800
1000
1200
Temperature (F)
225 200
Temperature (F)
70 Durometer
225 200
ML 2ML02 CURRENT
2 4 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.08
0.31
10 1 0.1 0.01
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Published information other than that marked certified is to be used as a guide only
ML
3ML02 2.875 270 1200 GPM PSI RPM
ML 3ML02 CURRENT
2 5 MAY 2008
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI 0 90
1.5
180
0.5
270
0 0.8
55 Durometer
CONTACT MONOFLO
MARK 3
2.5
150 100 50
MARK 1
PSI
1.5
0 90
0.5
180
200
400
800
1000
1200
Temperature (F)
225 200
Temperature (F)
70 Durometer
225 200
ML 3ML02 CURRENT
2 6 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.08
0.31
10 1 0.1 0.01
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Published information other than that marked certified is to be used as a guide only
ML
1ML03 8 90 1000 GPM PSI RPM
ML 1ML03 CURRENT
2 7 MAY 2008
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 30 60
90
1
PSI 90 60 30 0
55 Durometer
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 30
60
1
100
200
300
400
500
Pump Speed
600
700
800
900
1000
Temperature (F)
225 200
Temperature (F)
70 Durometer
225 200
ML 1ML03 CURRENT
2 8 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.12
0.48
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
ML
2ML03 8 180 1000 GPM PSI RPM
ML 2ML03 CURRENT
2 9 MAY 2008
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 60
120
180
1
55 Durometer
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 60
120
1
100
200
300
400
500
Pump Speed
600
700
800
900
1000
Temperature (F)
225 200
Temperature (F)
70 Durometer
225 200
ML 2ML03 CURRENT
2 10 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.12
0.48
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
ML
3ML03 8 270 1000 GPM PSI RPM
ML 3ML03 CURRENT
2 11 MAY 2008
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 90
180
270
1
CONTACT MONOFLO
MARK 3 MARK 1
150 100 50
PSI
5
0 90
180
1
100
200
300
400
500
Pump Speed
600
700
800
900
1000
Temperature (F)
55 Durometer
225 200
Temperature (F)
70 Durometer
225 200
ML 3ML03 CURRENT
2 12 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.12
0.48
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
ML
1ML04 20 90 1000 GPM PSI RPM
ML 1ML04 CURRENT
2 13 MAY 2008
20
70 Durometer
225
MARK 3 MARK 1
15
150 100 50
PSI
0
10
30 60
90
PSI 90 60 30 0
55 Durometer
225
MARK 3 MARK 1
15
150 100 50
PSI
0
10
30
60
0
100
200
300
400
600
700
800
900
1000
Temperature (F)
CONTACT MONOFLO
200
Temperature (F)
CONTACT MONOFLO
200
ML 1ML04 CURRENT
2 14 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.16
0.62
3.5
3.5
10 1 0.1 0.01
12
18
24
Published information other than that marked certified is to be used as a guide only
ML
2ML04 20 180 1000 GPM PSI RPM
ML 2ML04 CURRENT
2 15 MAY 2008
20
70 Durometer
225
MARK 3 MARK 1
15
150 100 50
PSI 0
10
60 120
180
55 Durometer
CONTACT MONOFLO
225
MARK 3 MARK 1
15
150 100 50
PSI 0
10
60
120
0
100
200
300
400
600
700
800
900
1000
Temperature (F)
200
Temperature (F)
CONTACT MONOFLO
200
ML 2ML04 CURRENT
2 16 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.16
0.62
10 1 0.1 0.01
12
18
24
Published information other than that marked certified is to be used as a guide only
ML
3ML04 20 270 1000 GPM PSI RPM
ML 3ML04 CURRENT
2 17 MAY 2008
225
70 Durometer
MARK 3 MARK 1
15
150 100
PSI
50 0
10
0 90 180
270
0 4
55 Durometer
CONTACT MONOFLO
225
MARK 3 MARK 1
15
150 100
PSI
50 0
10
90
5
180
0
100
200
300
400
600
700
800
900
1000
Temperature (F)
200
Temperature (F)
200
ML 3ML04 CURRENT
2 18 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.16
0.62
10.5
10.5
10 1 0.1 0.01
12
18
24
Published information other than that marked certified is to be used as a guide only
ML
1ML06 44.5 90 900 GPM PSI RPM
ML 1ML06 CURRENT
2 19 MAY 2008
45 40
MARK 3 MARK 1
CONTACT MONOFLO
35
30 25 20 15 10 5 0 4
PSI 0 30 60 90
PSI
3
90
2 1 0 45 40 35
225 200 150 100 50 0
60 30 0
MARK 3 MARK 1
CONTACT MONOFLO
30 25 20 15 10 5 0
PSI 0 30
60
150
300
600
750
900
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 1ML06 CURRENT
2 20 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.22
0.87
15
15
10 1 0.1 0.01
12
18
24
30
36
42
48
Published information other than that marked certified is to be used as a guide only
ML
2ML06 44.5 180 900 GPM PSI RPM
ML 2ML06 CURRENT
2 21 MAY 2008
45 40 35
MARK 3 MARK 1
CONTACT MONOFLO
30 25 20 15
10 5 0 6 5
4 3 2 1 0 45 40 35
MARK 3 MARK 1
CONTACT MONOFLO
30 25 20 15
PSI 0 60
120
10 5 0
150
300
600
750
900
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 2ML06 CURRENT
2 22 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.22
0.87
30
30
10 1 0.1 0.01
12
18
24
30
36
42
48
Published information other than that marked certified is to be used as a guide only
ML
3ML06 44.5 270 900 GPM PSI RPM
ML 3ML06 CURRENT
2 23 MAY 2008
45 40 35
MARK 3 MARK 1
CONTACT MONOFLO
30 25 20 15 10 5 0 10 8
PSI 270
180
4 2 0 45 40 35
CONTACT MONOFLO
90 0
MARK 3 MARK 1
30 25
PSI 0
20 15 10 5 0
90
180
150
300
600
750
900
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 3ML06 CURRENT
2 24 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.22
0.87
45
45
10 1 0.1 0.01
12
18
24
30
36
42
48
Published information other than that marked certified is to be used as a guide only
ML
1ML08 80 90 750 GPM PSI RPM
ML 1ML08 CURRENT
2 25 MAY 2008
225 200 150 100 50 0
80
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50
0
40
30 60
30 20
90
10 0
6 5 4 3 2 1 0 80
PSI 90 60 30 0
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50 40
0 30 60
30 20
10 0
150
300
450
Pump Speed (rpm)
600
750
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 1ML08 CURRENT
2 26 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.25
40
40
10 1 0.1 0.01
10
20
30
40
50
60
70
80
90
Published information other than that marked certified is to be used as a guide only
ML
2ML08 80 180 750 GPM PSI RPM
ML 2ML08 CURRENT
2 27 MAY 2008
225 200 150 100 50 0
80
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50 40
0 60 120
30 20
180
10 0
12 10 8 6 4 2 0 80
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50 40
0 60 120
30 20
10 0
150
300
450
Pump Speed (rpm)
600
750
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 2ML08 CURRENT
2 28 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.25
80
80
10 1 0.1 0.01
10
20
30
40
50
60
70
80
90
Published information other than that marked certified is to be used as a guide only
ML
3ML08 80 270 750 GPM PSI RPM
ML 3ML08 CURRENT
2 29 MAY 2008
225 200 150 100 50 0
80
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50 40
0 90 180
30 20
270
10 0 20
16 12 8 4 0 80
CONTACT MONOFLO
MARK 3
70
MARK 1
60
PSI
50 40
0 90 180
30 20
10 0
150
300
450
Pump Speed (rpm)
600
750
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 3ML08 CURRENT
2 30 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.31
1.25
120
120
10 1 0.1 0.01
10
20
30
40
50
60
70
80
90
Published information other than that marked certified is to be used as a guide only
ML
1ML10 108 90 600 GPM PSI RPM
ML 1ML10 CURRENT
2 31 MAY 2008
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 30 60
40
90
20
0 8
PSI 90 60 30
6 4 2 0 120
55 Durometer
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 30
40
60
20
100
200
400
500
600
Temperature (F)
225 200
Temperature (F)
120
70 Durometer
225 200
ML 1ML10 CURRENT
2 32 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.39
1.57
60
60
10 1 0.1 0.01
15
30
45
60
75
90
105 120
Published information other than that marked certified is to be used as a guide only
ML
2ML10 108 180 600 GPM PSI RPM
ML 2ML10 CURRENT
2 33 MAY 2008
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 60 120
40
180
20
0 15
PSI
12 9 6 3 0 120
180 120 60 0
55 Durometer
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 60
40
120
20
100
200
400
500
600
Temperature (F)
225 200
Temperature (F)
120
70 Durometer
225 200
ML 2ML10 CURRENT
2 34 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.39
1.57
100
100
10 1 0.1 0.01
15
30
45
60
75
90
105 120
Published information other than that marked certified is to be used as a guide only
ML
3ML10 108 270 600 GPM PSI RPM
ML 3ML10 CURRENT
2 35 MAY 2008
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 90 180 270
40
20
0 24
20 16 12 8 4 0 120
55 Durometer
CONTACT MONOFLO
MARK 3
100
150 100 50
MARK 1
80
PSI
60
0 90
40
180
20
100
200
400
500
600
Temperature (F)
225 200
Temperature (F)
120
70 Durometer
225 200
ML 3ML10 CURRENT
2 36 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.39
1.57
150
150
10 1 0.1 0.01
15
30
45
60
75
90
105 120
Published information other than that marked certified is to be used as a guide only
ML
1ML12 252 90 600 GPM PSI RPM
ML 1ML12 CURRENT
2 37 MAY 2008
270
CONTACT MONOFLO
MARK 3
240 210
MARK 1
180
PSI
150
0
120
30 60
90 60
90
30 0 20
PSI 90 60 30 0
Temperature (F)
55 Durometer
CONTACT MONOFLO
MARK 3 MARK 1
180
PSI
150 120
0 30
90 60
60
30 0
100
200
400
500
600
Temperature (F)
70 Durometer
ML 1ML12 CURRENT
2 38 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.90
60
60
10 1 0.1 0.01
40
80
120 160
Published information other than that marked certified is to be used as a guide only
ML
2ML12 252 180 600 GPM PSI RPM
ML 2ML12 CURRENT
2 39 MAY 2008
270
CONTACT MONOFLO
MARK 3
240 210
MARK 1
180
PSI
150 120
0 60 120
90 60
180
MARK 3 MARK 1
180
PSI
150
0
120
60
90 60
120
30 0
100
200
400
500
600
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 2ML12 CURRENT
2 40 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.90
120
120
10 1 0.1 0.01
40
80
120 160
Published information other than that marked certified is to be used as a guide only
ML
3ML12 252 270 600 GPM PSI RPM
ML 3ML12 CURRENT
2 41 MAY 2008
270
CONTACT MONOFLO
MARK 3
240 210
MARK 1
180
PSI
150
0
120
90 180
90 60
270
MARK 3 MARK 1
180
PSI
150
0
120
90
90 60
180
30 0
100
200
400
500
600
Temperature (F)
55 Durometer
Temperature (F)
70 Durometer
ML 3ML12 CURRENT
2 42 MAY 2008
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.47
1.90
180
180
10 1 0.1 0.01
40
80
120 160
Published information other than that marked certified is to be used as a guide only
ML
3 1
ALL CURRENT
MAY 2008
E CRS F
H APPROX. TO OBSTRUCTION
Published information other than that marked certified is to be used as a guide only
ML
3 2
ALL CURRENT
MAY 2008
Shaft Diameter (Inches) 0.80 1.11 1.29 1.63 2.12 2.50 3.50
No of Packing Rings 4 7 6 8 7
Packing Section (Square) (Inches) 0.20 0.25 0.38 0.38 0.50 0.50 0.63
Published information other than that marked certified is to be used as a guide only
ML ALL
CURRENT
3 3 MAY 2008
SUCTION END Pump Model 1ML02, 2ML02, 3ML02 1ML03, 2ML03, 3ML03 1ML04, 2ML04, 3ML04 1ML06, 2ML06, 3ML06 1ML08, 2ML08, 3ML08 1ML10, 2ML10, 3ML10 1ML12, 2ML12, 3ML12
All dimensions are in inches
Flange Std
A 1.00 1.50
Published information other than that marked certified is to be used as a guide only
ML ALL
CURRENT
SECTION PA GE DATE
3 4 MAY 2008
DISMANTLING DISTANCE J G H
G1
DISMANTLING DISTANCE L
MODEL No 1ML02 2ML02 3ML02 1ML03 2ML03 3ML03 1ML04 2ML04 3ML04 1ML06 2ML06 3ML06 1ML08 2ML08 3ML08 1ML10 2ML10 3ML10 1ML12 2ML12 3ML12
A 17.41 20.95 24.57 22.95 28.03 33.58 30.63 37.71 44.76 39.25 49.84 60.51 46.25 58.65 71.09 53.41 63.80 74.19 70.11 85.78 101.37
B 7.49 11.03 14.65 10.29 15.37 20.92 13.32 20.40 27.45 17.85 28.44 39.11 20.23 32.63 45.07 22.30 32.69 43.08 31.37 47.04 62.63
C 3.25 3.25 3.25 4.09 4.09 4.09 5.47 5.47 5.47 6.22 6.22 6.22 8.00 8.00 8.00 9.75 9.75 9.75 12.50 12.50 12.50
D 5.87 5.87 5.87 7.31 7.31 7.31 9.84 9.84 9.84 11.22 11.22 11.22 14.00 14.00 14.00 16.69 16.69 16.69 21.00 21.00 21.00
STANDARD PUMP DIMENSIONS (Inch) E F G G1 0.62 4.00 8.95 N/A 0.62 4.00 10.95 N/A 0.62 4.00 12.53 N/A 0.75 5.38 11.71 N/A 0.75 5.38 12.97 N/A 0.75 5.38 11.75 9.00 0.94 7.00 16.38 N/A 0.94 7.00 22.60 N/A 0.94 7.00 16.27 11.00 1.12 8.74 20.13 N/A 1.12 8.74 20.13 12.00 1.12 8.74 20.13 18.00 1.37 11.50 27.24 N/A 1.37 11.50 25.62 14.00 1.37 11.50 25.23 24.00 1.87 11.50 30.30 N/A 1.87 11.50 30.30 10.50 1.87 11.50 30.30 18.00 2.25 14.50 37.62 N/A 2.25 14.50 35.26 20.50 2.25 14.50 42.23 27.00
H 4.25 4.25 4.25 5.69 5.69 5.69 7.00 7.00 7.00 8.56 8.56 8.56 9.25 9.25 9.25 13.50 13.50 13.50 18.00 18.00 18.00
J 4.21 5.75 7.79 5.55 9.37 7.17 7.25 8.11 10.51 10.56 9.18 13.82 9.76 9.76 12.60 9.61 9.49 12.36 14.49 12.01 14.13
K 3.13 3.13 3.13 4.25 4.25 4.25 5.50 5.50 5.50 7.00 7.00 7.00 9.00 9.00 9.00 9.00 9.00 9.00 12.00 12.00 12.00
L 0.40 0.40 0.40 0.44 0.44 0.44 0.56 0.56 0.56 0.69 0.69 0.69 0.88 0.88 0.88 0.88 0.88 0.88 1.00 1.00 1.00
MODEL No 1ML02 2ML02 3ML02 1ML03 2ML03 3ML03 1ML04 2ML04 3ML04 1ML06 2ML06 3ML06 1ML08 2ML08 3ML08 1ML10 2ML10 3ML10 1ML12 2ML12 3ML12
SUCTION FLANGE SIZE M 1.00 4.25 1.00 4.25 1.00 4.25 1.50 5.00 1.50 5.00 1.50 5.00 2.50 7.00 2.50 7.00 2.50 7.00 3.00 7.50 3.00 7.50 3.00 7.50 4.00 9.00 4.00 9.00 4.00 9.00 6.00 11.00 6.00 11.00 6.00 11.00 8.00 13.50 8.00 13.50 8.00 13.50
DISCHARGE END SIZE 0.75 0.75 0.75 1.25 1.25 1.25 2.00 2.00 2.00 2.50 2.50 2.50 4.00 4.00 4.00 5.00 5.00 5.00 6.00 6.00 6.00
DISMANTLING DISTANCE 7.00 7.00 7.00 9.00 9.00 9.00 12.00 12.00 12.00 15.00 15.00 15.00 19.00 19.00 19.00 32.00 32.00 32.00 38.00 38.00 38.00
APPROX WEIGHT LBS 22.00 25.00 31.00 47.00 51.00 55.00 85.00 91.00 97.00 141.00 159.00 192.00 303.00 332.00 372.00 412.00 500.00 545.00 880.00 1075.00 1200.00
Published information other than that marked certified is to be used as a guide only
XL Range Pumps
A gear-joint pump available in bare shaft configurations
XL Range
Typical Applications
A range of pumps designed to be directly interchangeable with traditional gear joint style pumps.
Municipal sludge & lime slurry Mineral processing Pressure up to 180 psi Industrial chemicals, detergents and polymers Temperature 20oF up to 230oF Crude oil and waste oil Coating slurry, starch and clays Capacity
up to 742 gpm
Robust gear joint Materials of construction Low running speeds Gentle pumping action Up to 28ft suction lift High pressure / long haul pumping Versatile
Heavy duty gear joint design for demanding applications. Available in cast iron with a choice of rotor and stator materials to suit individual applications. Reduced wear for a longer working pump life which extends the periods between routine maintenance. Think of the savings that could be realized on abrasive applications. Minimizes shear and crush damage to the pumped product, whilst maintaining a steady flow when pumping products with a high solids content. Deep sumps can be easily emptied without the use of submersible equipment. Can offer considerable project cost savings by utilizing small bore pipework and eliminating the need for a series of pumps, when pumping over long distances or with high head requirements. Can be run in either direction.
Performance Data
742 565
SINGLE STAGE
TWO STAGE
1XLJ175
2XLJ175
1XLH115 435 1XLG090 CAPACITY GPM 370 1XLG065 285 1XLF050 222 1XLF036 158 1XLE022 88 1XLE012 0 0 90
2XLH115
2XLG090
2XLG065
2XLF050
2XLF036
2XLE022
2XLE012
180
Dimensions
STANDARD PUMP DIMENSIONS MODEL 1XLE012 2XLE012 1XLE022 2XLE022 1XLF036 2XLF036 1XLF050 2XLF050 1XLG065 2XLG065 1XLG090 2XLG090 1XLH115 2XLH115 1XLJ175 2XLJ175 A 42 53 43 56 49 49 54 74 57 75 64 89 67 90 75 101 B 16 27 17 30 20 34 25 45 24 42 30 56 31 54 34 61 C 6 6 6 6 7 7 7 7 9 9 9 9 11 11 11 11 D 12 12 13 13 14 14 14 14 18 18 18 18 20 20 22 22 E 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 F 8 8 8 8 10 10 10 10 12 12 12 12 15 15 15 15 SUCTION FLANGE DISCHARGE FLANGE SIZE 4 4 6 6 6 6 6 6 8 8 8 8 8 8 10 10 M 9 9 11 11 11 11 11 11 14 14 14 14 14 14 16 16 SIZE 4 4 6 6 6 6 6 6 8 8 8 8 8 8 10 10 M1 9 9 11 11 11 11 11 11 14 14 14 14 14 14 16 16 APPROX WEIGHT LBS 300 325 330 370 490 560 520 610 760 882 805 960 1110 1185 1555 1840
All dimensions in inches and for guidance only. Flanges to ANSI B16.1 and NPT pipe thread.
SUCTION
M1
D C
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-XL/R1 Monoflo is a registered trademark of Mono Pumps Ltd.
XL ALL CURRENT
1 1 MAR 2008
SELECTION PROCEDURE
PUMP SIZING 1 From the pre-selection table (page 5) select the pump model which initially meets the required capacity / pressure criteria. (Refer to NOTES on page 4) 2 Referring to the performance data in sections 2 & 3 if particle size is a factor then refer to the table labelled SOLIDS HANDLING (inches) on the performance graph to verify the pumps suitability. 3 If variable speed is required then select at maximum capacity. 4 On the y-axis (Capacity) identify the required flow then move horizontally until intersection at the required differential pressure.(see 5). 5 Slip Correction for Viscosity a) If Viscosity is equal to or greater than six (6) stokes then select on the zero PSI pressure line to determine the pump speed required for the duty. From the point of intersection on the curve move vertically down to the x-axis labelled Speed to obtain the required RPM. b) If the viscosity is less than six (6) stokes then the following procedure applies:Use the method given here as Figs. 1 and 2 to estimate Slip and calculate the required pump speed. Slip Correction for Viscosity n = np - [ (np - no) f ] or n = np - f.ns where n = corrected duty speed no = rpm at zero PSI for duty flow rate (from water performance curves) np = rpm at duty pressure for duty flow rate (from water performance curves (Fig 1)) np-no = Slip speed = ns From viscous slip curve (Fig 2) read slip factor f f x ns = slip speed correction = f.ns Corrected Speed for Duty n = np - f.ns
SLIP FACTOR (f)
Example
176
PERFORMANCE CURVES BASED ON WATER AT 68F
CAPACITY (GPM)
132
0 PSI 60 PSI
88
44 no
np
100
200
300
400
500
SPEED RPM
Fig 1 Duty 88gpm, 60 PSI 100 centistokes (viscosity in pump) Corrected Duty Speed n = np - [ (np - no) f ] n = 410 - [ (410-300) x .78 ] = 324 rpm or n = np - f.ns n = 410 - 85.5 = 324 rpm
SLIP CORRECTION FOR VISCOSITY 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
Fig 2 Note: There is no slip correction necessary for water or product with a viscosity of one (1) centistoke.
Published information other than that marked certified is to be used as a guide only
XL ALL CURRENT
1 2 MAR 2008
SELECTION PROCEDURE
6 When RPM is established identify: a) Maximum viscosity as indicated at the top of the performance curve labelled Viscosity Limits. Refer to page 3, Tolerance guidelines - Viscosity Limits. b) Abrasion capability as indicated at the top of the performance curve labelled Abrasion zone. Refer to page 3, Tolerance guidelines - Abrasion zone. If any of the parameters in steps 1 to 6 (b) do not meet the required criteria then re-select from (1) above with the next largest pump size. c) Rotor selection against temperature as indicated in the shaded area of the performance curve for the duty speed identified. Refer to Tolerance guidelines - Rotor selection. d) Absorbed power which is read on the y-axis (Absorbed power) at the differential pressure intersection point (BHP). If the product is viscous then note also the absorbed power on the zero pressure line (FHP) for use later in calculation. 7 If the pump meets the above criteria go to the PUMP CONFIRMATION SECTION. If no pump can be identified then please contact Monoflo for assistance. PUMP CONFIRMATION Having determined the pump size the following steps are necessary: 1 Read the NPSH required from the pump curve at the duty flowrate. Check that the N.P.S.H. required is less than N.P.S.H. available. 2 Note the starting torque required on the performance curve in the table labelled STARTING TORQUE against the selected rotor. 3 If the product is viscous obtain both Starting Torque (f T) and Power Additive (f FHP) factors from the Viscosity Curve graph read at the known viscosity in Stokes. 4 Confirm stator suitability for the product. (Refer to page 3, Tolerance guidelines - Stator selection) 5 Confirm material compatibility and availability for the pump chosen. 6 Select mechanical seal (standard) or packed gland as required. Information obtained from the PUMP DRIVE CONFIRMATION section will be used to determine the required drive. 1 If product is water like, then the absorbed power (BHP) will be as obtained in the PUMP SIZING section, step 6, item (d). Go to step 4. 2 Multiplying the pump starting torque by the starting torque factor obtained in the PUMP CONFIRMATION section, item 3 will give you the starting torque required for the given viscosity. (ie T(lb-ft) x fT = Starting torque at viscosity).(Refer to section DRIVE, items 5 and 6) 3 To obtain the power absorbed at the known viscosity then the full viscous calculation is: Viscous Brake Horsepower (V BHP) = Viscous frictional H.P. + W.H.P. a) Viscous Frictional Horsepower FHP x f FHP. FHP as identified in Pump Sizing section step 6, item (d) (zero PSI pressure). f FHP factor as identified in Pump Confirmation section step 3. Multiply FHP by correction factor f FHP to give frictional horsepower when handling the viscous product. b) Water Horsepower (WHP) is BHP - FHP BHP as identified in Pump Sizing section step 6, item (d) (at duty pressure). FHP as identified in Pump Sizing section step 6, item (d) (at zero PSI pressure). WHP is BHP - FHP c) Add viscous frictional horsepower to water horsepower to obtain BHP absorbed when handling a viscous product i.e. a + b.
4 Determine the motor input power required by allowing for the efficiency of the drive arrangement as follows: Efficiency % Drive Arrangement D.C. to a synchronous speed motor 100 D.C. to a fixed speed geared motor 92 D.C. to a variable speed geared motor 80 (D.C. = Direct Coupled) Therefore input power = BHP (or vBHP) divided by the efficiency.(ie. Input power required for a close coupled CB pump with a direct coupled fixed speed geared motor = BHP (or vBHP) / 0.92)
XL ALL CURRENT
1 3 SEPT 2008
SELECTION PROCEDURE
5 Starting torque capabilities will be affected by the type of drive selected and method of starting. Generally motors wired for D.O.L. start on a 3 phase supply will provide 200% FLT (Full Load Torque). Motors wired for Star/Delta start on a 3 phase supply typically provide 50-70% FLT. Single phase motors (capacitor start) typically provide 200% FLT. In all cases reference should be made to the motor manufacturers performance tables. D.O.L. is the preferred method of starting a PC pump. 6 If starting is via an inverter type of drive then 125% FLT availability only is assumed. The correct matching of drive motor/inverter/pump is a specialised skill. Breakout torque and continuous slow running can cause problems. Always refer an inverter application to a specialist drive company, ensuring that they are aware of the full duty parameters to enable them to select the appropriate drive package. 7 Starting with a soft starter should be referred to the manufacturers specification, but typically starting torque will be 150% FLT. 8 Care should be taken when selecting other types of drives to ensure sufficient starting torque is available, i.e. single phase, hydraulic drives, air motors, engines etc. If in doubt refer to Monoflo. TOLERANCE GUIDELINES Rotor Selection Consider maximum fluid temperature, ambient temperature, operating speed and duration of running. All these factors affect stator temperature, in borderline cases select the higher temperature rotor. Fixed Speed If selection falls exactly between rotor types then select the higher temperature rotor. Variable Speed For variable speed drives select the rotor at maximum speed and maximum temperature. Stator Selection Performance curves based on Buna and Natural stator materials.
Stator Options
Code CR CB CQ CF D escrip tio n N atural R ubber EPDM N itrile R ubber F luoroelastom er M ax T em p F 158 266 230 300
80D2434
Published information other than that marked certified is to be used as a guide only
PUMP MODEL
XL ALL CURRENT
1 4 MAR 2008
STATUS
SELECTION PROCEDURE
NOTES Flow Rate The expected accuracy of progressing cavity pumps is 10% of pump maximum flowrate as shown by the Product Manual Curves. If specific duty points must be achieved ensure that Monoflo are aware of this. Pressure has a proportional effect on wear therefore increasing the number of stages at constant pressure will significantly improve component life. PUMP ROTATION (DOG/SOG) The pump rotation is normally assumed clockwise (when looking on the pump drive shaft end) such that SOG (Suction-On-Gland) flow conditions prevail (ie, product enters at the suction chamber and leaves at the discharge chamber). PRESSURE LIMITATIONS The construction of each different range of pumps will result in maximum discharge pressures and maximum differential pressures that may differ depending upon the specific model, direction of rotation and port fittings. It is therefore important to check that both the differential pressure plus the inlet pressure do not exceed the maximum discharge pressure for the pump selected. TEMPERATURE LIMITATIONS Temperature limitations are dependant on material combinations used. If duty temperatures are outside the limits shown for a particular combination please contact Monoflo for guidance. SPEED LIMITATIONS If speeds below 50rpm are required then please contact Monoflo for assistance.
MAX DIFFERENTIAL PRESSURE - PSI SOG DOG 1 2 1 2 90 180 30 30 MAX DISCHARGE PRESSURE - PSI SOG DOG 1 2 1 2 120 200 30 30
NOTE: 1. Figures shown are based on temperatures of 68OF 2. SOG: Suction on Gland DOG: Delivery on Gland 3: For optional part fittings contact Monoflo to confirm maximum pressure ratings when high temperatures are experienced.
Published information other than that marked certified is to be used as a guide only
XL
1 5
ALL CURRENT
MAR 2008
742
565 1XLH115 435 1XLG090 CAPACITY GPM 370 1XLG065 1XLH065 285 1XLF050 222 1XLF036 158 1XLE022 88 1XLE012 0 2XLE012 2XLE022 2XLF036 2XLF050 2XLG065 2XLH065 2XLG090 2XLH115
180
Published information other than that marked certified is to be used as a guide only
XL ALL CURRENT
1 6 NOV 2008
Pump Code 4 5 6 7 8 9
Type Designation 10 11 12
E F G H J 0 0 0 0 0 0 1 1 1 2 3 5 6 9 1 7 2 2 6 0 5 0 5 5 E F G H J 1 2 3 C D S B F Q R A 1 X L F 0 3 6 F 1 C D Q A A A A A
222 GPM 285 GPM 370 GPM 435 GPM 565 GPM 742 GPM E Size F Size
Vertical Left (veiwed from drive end) Right (veiwed from drive end) Cast Iron Plated Alloy Steel Plated 316 Stainless Steel EPDM Fluroelastomer Nitrile (Buna) Natural Rubber Standard Rotor, Packed Gland Example:
Note: For Standard Part Variations other than AAA consult Monoflo.
Published information other than that marked certified is to be used as a guide only
XL ALL CURRENT
1 7 MAR 2008
10000
1000
Starting Torque
Power Additive
100
10
0.1
0.01 1 2 3 4 5 6 7
Correction Factor
XL
1 8
ALL CURRENT
MAR 2008
CR Black Natural
CQ Nitrile
14F (-10C) 41F (5C) 23F (-5C) 158F (70C) 266F (130C) 230F (110C) None None None Yes Yes Yes Temperatures are for continuous operating conditions
CV Refer to Speed/Pressure derate graph for limitations. The power absorbed must be increased by a factor of 1.2. Applications above (88F) 50C Should be refered back to Monoflo.
SPEED / PRESSURE DERATE WHEN USING CF STATORS (UP TO 50oC) (880F) (Moulded to metal stators only)
100%
NOT SUITABLE
75%
Rated Speed
50%
25%
XL ALL CURRENT
1 9 MAR 2008
XL
1XLE012 88 90 750 GPM PSI RPM
XL 1XLE012 CURRENT
PERFORMANCE DATA
2 1 Dec 2007
90
CONTACT MONOFLO
60
30
15
0 7
PSI 90 60 30 0
60
PSI 0 30 60
45
30
15
0
0 100 200 300 400 500 600 700
Pump Speed (rpm)
Published information other than that marked certified is to be used as a guide only
XL 1XLE012 CURRENT
2 2
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.35
1.42
53
53
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 9 8 Pump N.P.S.H. Required Feet head of water 7 6 5 4 3 2 1 0 1 2 4 5 3 Correction Factor 6 7 0
10 1 0.1 0.01
20
40
60
80
100
Published information other than that marked certified is to be used as a guide only
XL
2XLE012 88 180 750 GPM PSI RPM
XL 2XLE012 CURRENT
PERFORMANCE DATA
2 3 Dec 2007
150 100 50
MARK 1
60
45
30
15
0
12 10 8 6 4 2 0
150 100 50
75
MARK 1
60
PSI 0 60 120
45
30
15
0
0 100 200 300 400 Pump Speed (rpm) 500 600 700
Published information other than that marked certified is to be used as a guide only
Temperature (F)
90
225 200
Temperature (F)
90
225 200
XL 2XLE012 CURRENT
2 4
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.35
1.42
88
88
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 9 8 Pump N.P.S.H. Required Feet head of water 7 6 5 4 3 2 1
Published information other than that marked certified is to be used as a guide only
XL
1XLE022 158 90 725 GPM PSI RPM
XL 1XLE022 CURRENT
PERFORMANCE DATA
2 5 Dec 2007
MARK 3 MARK 1
150 100 50 0
PSI 0 30 60 90
10 8 6 4 2 0
MARK 3 MARK 1
150 100 50 0
PSI
100 80
0 30 60
60 40 20 0 0 100 200 300 400 Pump Speed (rpm) 500 600 700
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 1XLE022 CURRENT
2 6
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.44
1.77
88
88
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 12 10 Pump N.P.S.H. Required Feet head of water 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
2XLE022 158 180 725 GPM PSI RPM
XL 2XLE022 CURRENT
PERFORMANCE DATA
2 7 Dec 2007
MARK 3 MARK 1
150 100 50 0
MARK 3 MARK 1
150 100 50 0
PSI 0 60 120
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 2XLE022 CURRENT
2 8
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.44
1.77
132
132
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 12 10 Pump N.P.S.H. Required Feet head of water 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
20 40
Published information other than that marked certified is to be used as a guide only
XL
1XLF036 222 90 650 GPM PSI RPM
XL 1XLF036 CURRENT
2 9 Dec 2007
MARK 3
200
150 100 50
MARK 1
160
PSI
120
0 30 60 90
80
40
0 16
14 12 10 8 6 4 2 0
150 100 50
200
MARK 1
160
PSI
120
0 30 60
80
40
Published information other than that marked certified is to be used as a guide only
Temperature (F)
240
225 200
Temperature (F)
240
225 200
XL 1XLF036 CURRENT
2 10
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.2
132
132
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 12 10 Pump N.P.S.H. Required Feet head of water 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7 0
10 1 0.1 0.01
50
100
150
200
250
Published information other than that marked certified is to be used as a guide only
XL
2XLF036 222 180 650 GPM PSI RPM
XL 2XLF036 CURRENT
2 11 Dec 2007
200
150 100 50 0
160
120
80
40
0 28
24 20 16 12 8 4 0
MARK 3
200
150 100 50 0
MARK 1 PSI 0 60
160
120
120
80
40
400
500
600
Published information other than that marked certified is to be used as a guide only
Temperature (F)
240
225 200
Temperature (F)
225 200
XL 2XLF036 CURRENT
2 12
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.2
234
234
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 12 10 Pump N.P.S.H. Required Feet head of water 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7 0
10 1 0.1 0.01
50
100
150
200
250
Published information other than that marked certified is to be used as a guide only
XL
1XLF050 285 90 600 GPM PSI RPM
XL 1XLF050 CURRENT
PERFORMANCE DATA
2 13 Dec 2007
MARK 3
250
150 100 50
MARK 1
200
PSI 0
150
30 60 90
100
50
0 20 18 16 14 12 10 8 6 4 2 0
Temperature (F)
300
250
200
PSI
150
0 30 60
100
50
Published information other than that marked certified is to be used as a guide only
Temperature (F)
300
225 200
XL 1XLF050 CURRENT
2 14
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.21
106
106
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7 0
10 1 0.1 0.01
50
100
150
200
250
300
Published information other than that marked certified is to be used as a guide only
XL
2XLF050 285 180 600 GPM PSI RPM
XL 2XLF050 CURRENT
PERFORMANCE DATA
2 15 Dec 2007
MARK 3
250
150 100 50
MARK 1
200
PSI 0 60
150
120 180
100
50
0 36 32
28 24 20 16 12 8 4 0
MARK 3
250
150 100 50
MARK 1
200
PSI 0 60
150
120
100
50
400
500
600
Published information other than that marked certified is to be used as a guide only
Temperature (F)
300
225 200
Temperature (F)
300
225 200
XL 2XLF050 CURRENT
2 16
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.55
2.21
198
198
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7 0 50
10 1 0.1 0.01
100
150
200
250
300
Published information other than that marked certified is to be used as a guide only
XL
1XLG065 370 90 575 GPM PSI RPM
XL 1XLG065 CURRENT
2 17 Dec 2007
150 100 50 0
20 16 12 8 4 0
PSI 90 60 30 0
MARK 3 MARK 1
150 100 50 0
PSI 0 30
240 200 160 120 80 40 0 0 50 100 150 200 250 300 350 Pump Speed (rpm)
60
400
450
500
550
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 1XLG065 CURRENT
2 18
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
170
170
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0 50
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
2XLG065 370 180 575 GPM PSI RPM
XL 2XLG065 CURRENT
2 19 Dec 2007
150 100 50 0
40 32 24 16 8 0
MARK 3 MARK 1
150 100 50 0
PSI 0 60
120
50
100
150
200
400
450
500
550
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 2XLG065 CURRENT
2 20
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
300
300
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
50
Published information other than that marked certified is to be used as a guide only
XL
1XLH065 370 90 575 GPM PSI RPM
XL 1XLH065 CURRENT
2 21 Dec 2007
150 100 50 0
150 100 50 0
PSI 0 30
240 200 160 120 80 40 0 0 50 100 150 200 250 300 350 Pump Speed (rpm)
60
400
450
500
550
Published information other than that marked certified is to be used as a guide only
Temperature (F)
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 1XLH065 CURRENT
2 22
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
351
351
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0 50
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
2XLH065 370 180 575 GPM PSI RPM
XL 2XLH065 CURRENT
2 23 Dec 2007
150 100 50 0
40 32 24 16 8 0
MARK 3 MARK 1
150 100 50 0
PSI 0 60
120
50
100
150
200
400
450
500
550
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
CONTACT MONOFLO
225 200
XL 2XLH065 CURRENT
2 24
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns) Above data represents tests on water @ 68F
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
170
170
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
50
Published information other than that marked certified is to be used as a guide only
XL
1XLG090 435 90 500 GPM PSI RPM
XL 1XLG090 CURRENT
2 25 Dec 2007
450 420 390 360 330 300 270 240 210 180 150 120 90 60 30 0 28
150 100 50 0
PSI 0 30 60 90
24 20 16 12 8 4 0
Temperature (F)
480 450 420 390 360 330 300 270 240 210 180 150 120 90 60 30 0
PSI 0 30
60
50
100
150
200
350
400
450
500
Published information other than that marked certified is to be used as a guide only
Temperature (F)
480
CONTACT MONOFLO
225 200
XL 1XLG090 CURRENT
2 26
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
300
300
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
2XLG090 435 180 500 GPM PSI RPM
XL 2XLG090 CURRENT
2 27 Dec 2007
450 420 390 360 330 300 270 240 210 180 150 120 90 60 30 0 56
150 100 50 0
48 40 32 24 16 8 0
Temperature (F)
PSI 180 120 60 0 55 DUROMETER - CR RUBBER ONLY CONTACT MONOFLO MARK 3 MARK 1
480 450 420 390 360 330 300 270 240 210 180 150 120 90 60 30 0 0
PSI 0 60
120
50
100
150
350
400
450
500
Published information other than that marked certified is to be used as a guide only
Temperature (F)
480
CONTACT MONOFLO
225 200
XL 2XLG090 CURRENT
2 28
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.67
2.69
395
395
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 14 12 Pump N.P.S.H. Required Feet head of water 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
0
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
1XLH115 565 90 500 GPM PSI RPM
XL 1XLH115 CURRENT
2 29 Dec 2007
150 100 50
500
MARK 1 PSI
400
0 30 60 90
300
200
100
0 40 35
30 25 20 15 10 5 0
150 100 50
500
MARK 1
400
PSI 0 30
300
60
200
100
50
100
150
200
350
400
450
500
Published information other than that marked certified is to be used as a guide only
Temperature (F)
600
225 200
Temperature (F)
600
CONTACT MONOFLO
225 200
XL 1XLH115 CURRENT
2 30
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.78
3.13
351
351
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 16 14 Pump N.P.S.H. Required Feet head of water 12 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7 0
10 1 0.1 0.01
100
200
300
400
500
600
Published information other than that marked certified is to be used as a guide only
XL
2XLH115 565 180 500 GPM PSI RPM
XL 2XLH115 CURRENT
2 31 Dec 2007
150 100 50 0
500
400
300
200
100
0
70 60
50 40 30 20 10 0
55 DUROMETER - CR RUBBER ONLY
MARK 3
150 100 50 0
500
MARK 1
PSI 0 60
400
300
120
200
100
50
100
150
200
250
300
350
400
450
500
Published information other than that marked certified is to be used as a guide only
Temperature (F)
600
CONTACT MONOFLO
225 200
Temperature (F)
600
CONTACT MONOFLO
225 200
XL 2XLH115 CURRENT
2 32
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.78
3.13
410
410
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 16 14 Pump N.P.S.H. Required Feet head of water 12 10 8 6 4 2 0 1 2 4 5 3 Correction Factor 6 7
10 1 0.1 0.01
100
600
Published information other than that marked certified is to be used as a guide only
XL
1XLJ175 742 90 450 GPM PSI RPM
XL 1XLJ175 CURRENT
2 33 Dec 2007
700
150 100 50 0
PSI 0 30 60 90
40 35 30 25 20 15 10 5 0 800 700
55 DUROMETER - CR RUBBER ONLY
PSI 90 60 30 0
MARK 3 MARK 1
150 100 50 0
PSI 0 30 60
50
100
150
200
250
300
350
400
450
Published information other than that marked certified is to be used as a guide only
Temperature (F)
CONTACT MONOFLO
225 200
Temperature (F)
800
CONTACT MONOFLO
225 200
XL 1XLJ175 CURRENT
2 34
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.90
3.61
220
220
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE Pump N.P.S.H. Required Feet head of water
0
0 100 200 300 400 500 600 700 800
Published information other than that marked certified is to be used as a guide only
XL
2XLJ175 742 180 450 GPM PSI RPM
XL 2XLJ175 CURRENT
2 35 Dec 2007
700 600
150 100 50 0
180
PSI 180 120 60 0 55 DUROMETER - CR RUBBER ONLY CONTACT MONOFLO MARK 3 MARK 1 PSI 0 60
700 600
150 100 50 0
120
50
100
150
200
250
300
350
400
450
Published information other than that marked certified is to be used as a guide only
Temperature (F)
800
225 200
Temperature (F)
800
CONTACT MONOFLO
225 200
XL 2XLJ175 CURRENT
2 36
Dec 2007
GENERAL DATA
Rotor Selection
SLIP CORRECTION FOR VISCOSITY 1.0
n = corrected duty speed, no = rpm @ 0 PSI, n p = rpm @ duty press. ns = Slip Speed = np - no , f x n s = Slip Speed Correction = f.ns Slip Corrected Speed (n = n p - f.ns)
SLIP FACTOR (f)
0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 10 100 1000 VISCOSITY IN PUMP (CENTISTOKES)
0.90
3.61
841
841
VISCOSITY ADDITIVES STARTING TORQUE POWER ADDITIVE 16 14 Pump N.P.S.H. Required Feet head of water 12 10 8 6 4 2 1 2 4 5 3 Correction Factor 6 7 0
0
10 1 0.1 0.01
Published information other than that marked certified is to be used as a guide only
XL
3 1
ALL CURRENT
MAY 2008
A (SHAFT
F APPROX TO OBSTRUCTION
Pump model E012 E022 F036 F050 G065 G090 H065 H115 J175 4.50 3.75 3.25 2.75
A + 0.000 - 0.002 + 0.002 - 0.002 + 0.000 - 0.002 + 0.002 - 0.002 + 0.002 - 0.002 6.00 5.00 4.50 3.75
B + 0.006 - 0.000 + 0.008 - 0.000 + 0.008 - 0.000 + 0.008 - 0.000 + 0.008 - 0.000
C (P .C .D ) + 0.008 - 0.008 5.00 + 0.008 - 0.008 5.87 + 0.008 - 0.008 6.50 + 0.008 - 0.008 7.75 + 0.008 - 0.008
2.25
3.23
4.41
5.00
4.21
2.88
0.315
1.25
3/8" - 16 UNC
1.0
5.87
4.44
2.88
0.315
1.25
3/8" - 16 UNC
1.0
6.75
4.94
3.75
0.423
1.25
1/2" - 13 UNC
1.0
7.50
4.94
3.94
0.531
1.25
5/8" - 11 UNC
1.0
8.75
5.75
4.56
0.531
1.25
5/8" - 11 UNC
1.0
Published information other than that marked certified is to be used as a guide only
XL
3 2
ALL CURRENT
MAR 2008
Pump Model(s) E012, E022 F036, F050 G065, G090 H065, H115 J175
Published information other than that marked certified is to be used as a guide only
XL ALL
CURRENT
SECTION PA GE DATE
3 3 MAR 2008
A 4 6 8 10
Flange Std.
A 4 6 8 10
Dimensions in inches
Published information other than that marked certified is to be used as a guide only
XL ALL
CURRENT
SECTION PA GE DATE
3 4 MAR 2008
L G1 G H J
+ 0.25 A -
SUCTION
M1
D C
K F
Model No 1E 012 2E 012 1E 022 2E 022 1F 036 2F 036 1F 050 2F 050 1G 065 2G 065 1G 090 2G 090 1H 065 2H 065 1H 115 2H 115 1J175 2J175
A 42.00 53.12 43.31 56.19 48.62 63.12 53.94 73.75 56.88 74.75 63.38 87.88 61.08 78.84 66.50 89.88 74.75 101.38
B 16.12 27.25 17.19 30.06 19.62 34.12 24.94 44.75 23.75 41.62 30.25 54.75 25.38 43.14 30.88 54.25 33.88 60.50
C 6.00 6.00 6.00 6.00 7.00 7.00 7.00 7.00 9.00 9.00 9.00 9.00 11.00 11.00 11.00 11.00 11.00 11.00
D 11.50 11.50 12.50 12.50 14.00 14.00 14.00 14.00 17.50 17.50 17.50 17.50 19.50 19.50 19.50 19.50 21.50 21.50
STANDARD PUMP DIMENSIONS (Inch) E F G 1.88 8.00 18.00 1.88 8.00 22.00 1.88 8.50 18.00 1.88 8.50 27.00 2.12 10.00 21.00 2.12 10.00 29.00 2.12 10.00 25.00 2.12 10.00 34.00 2.38 12.00 26.00 2.38 12.00 34.00 2.38 12.00 29.00 2.38 12.00 40.00 2.88 15.00 27.00 2.88 15.00 36.00 2.88 15.00 30.00 2.88 15.00 54.00 3.38 15.00 30.00 3.38 15.00 60.00
G1 N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A N /A 30.00
H 5.50 5.50 5.50 5.50 6.75 6.75 6.75 6.75 7.75 7.75 7.75 7.75 9.50 9.50 9.50 9.50 12.00 12.00
J 11.94 11.94 11.94 11.94 13.00 13.00 13.00 13.00 14.50 14.50 14.50 14.50 15.12 15.12 15.12 15.12 16.00 16.00
K 6.50 6.50 6.50 6.50 8.50 8.50 8.50 8.50 9.50 9.50 9.50 9.50 13.00 13.00 13.00 13.00 13.00 13.00
L 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 1.00 1.00 1.00 1.00 1.00 1.00
Model No 1E 012 2E 012 1E 022 2E 022 1F 036 2F 036 1F 050 2F 050 1G 065 2G 065 1G 090 2G 090 1H 065 2H 065 1H 115 2H 115 1J175 2J175
SUCTION FLANGE S IZ E M 4 9.00 4 9.00 6 11.00 6 11.00 6 11.00 6 11.00 6 11.00 6 11.00 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 10 16.00 10 16.00
DISCHARGE FLANGE S IZ E M1 4 9.00 4 9.00 6 11.00 6 11.00 6 11.00 6 11.00 6 11.00 6 11.00 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 8 13.50 10 16.00 10 16.00
DISMANTLING DISTANCE 7.00 7.00 7.00 7.00 8.00 8.00 8.00 8.00 7.00 7.00 7.00 7.00 7.00 7.00 10.00 10.00 12.00 12.00
APPROX WEIGHT LBS 300 325 330 370 490 560 520 610 760 882 805 960 768 975 1110 1185 1555 1840
Published information other than that marked certified is to be used as a guide only
Brushless DC Motor
Solar Controllers
Rotor / Stator
Americas Monoo Inc., 10529 Fisher Road Houston, Texas 77041, USA T. +1 713 980 8400 E. inquire@monoo.com Monoo S.A., Ing Huergo 2239 (1842) Monte Grande Pcia. de Buenos Aires, Argentina T. +54 11 4290 9940/50 E. info@monoo.com.ar Australasia Mono Pumps (Australia) Pty Ltd Mono House, 338-348 Lower Dandenong Road Mordialloc, Victoria 3195, Australia T. +61 (0)3 9580 5211 E. ozsales@mono-pumps.com Mono Pumps (New Zealand) Ltd PO Box 71-021, Fremlin Place, Avondale Auckland 7, New Zealand T. +64 (0)9 829 0333 E. info@mono-pumps.co.nz Asia Mono Pumps Ltd, No. 500 YaGang Road Lujia Village, Malu, Jiading District Shanghai 201801, P.R. China T. +86 (0)21 5915 7168 E. monoshanghai@nov.com Europe Mono Pumps Ltd, Martin Street, Audenshaw Manchester, M34 5JA, England T. +44 (0)161 339 9000 E. info@mono-pumps.com D.M.I EST, 56, rue du Pont 88300 Rebeuville, France T. +33 (0)3 29 94 26 88 E. dmi-est@dmi-est.fr www.monoo.com
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoos standard terms and conditions of sale, available on request. Monoo products are marketed outside North America under the mark Mono. Monoo is a registered trademark of Mono Pumps Ltd. Literature reference: ART29US/4 January 2008
Highly efficient, fullyintegrated de-watering solutions for reducing the total cost of a mine de-watering program.
Typical applications include: Mine de-watering Pastes of ground limes Cements Polyelectrolyte flocculent Coal slurries China clays Grout placing Strata control
5 6 1 4
1. Rotor - HCP Monoflo DF mining pumps are fitted with hard chrome plated rotors to minimize operating costs by significantly extending the life of the rotor and stator. Attention is paid to the rotor profile to maximize efficiency and part life. Other higher grade rotor coatings are available on request for highly corrosive applications.
2. PowerDrive The Monoflo designed and patented PowerDrive has been proven over 40 years service. Through the elimination of wearing parts the PowerDrive allows for a maintenance free drive train with optimum reliability. The PowerDrive is protected with an inert Halar coating and comes with a 5 year warranty.
3. Gland Monoflo has again gone to the forefront of design and improvement of mining pumps. The DF pumps are designed with high quality graphite gland packing, which has been successfully used in the mining industry worldwide for close to 50 years.
To minimise the impact on the environment, this has been printed on recycled paper
3 2 7
4. Tie Bars & Anti-Rotation Rings The use of tie bars with the addition of anti-reversing rings is the recommended solution for elimination of the stator moving when in place.
5. Stator Stator is made of resilient and abrasion resistant synthetic rubber compound (Nitrile). Dimensional accuracy is assured through sophisticated co-ordinate measuring technologies.
6. End Cover DF pumps are fitted with marine grade NI-Resist end covers and adaptor flanges to minimize the effects of erosion, corrosion and leakage traditionally found in stainless steel and cast iron end covers.
7. Bearing Housing The bearing housing is sealed by labyrinth rings and lipseals with grease packing to exclude any grit, dirt and water from the bearings. The housing is supplied complete with three bearings greasing points to lubricate the bearings and to pack labyrinth seals to maintain a robust barrier, preventing ingress of any foreign matter into the bearing chamber.
5 1 3
8 4 2 6 7
2. Base Heavy duty, hot dipped, galvanized base standard with liftiing points, drag bars and fork lift slots.
3. Belt & Pulley Guards All pulley guards designed and manufactured by Monoflo are made to comply with OSHA standards,
4. Grease Point Single efficient greasing point for both the pump and motor.
5. Hopper (Option) Heavy duty hopper seam welded from 1/4 steel, sand blasted and painted with a high quality two part epoxy to suit the general mine environment.
6. Dump Manifold (Option) The dump manifold is integrated with the internal overflow pipe.
7. Discharge Pipework (Option) Discharge pipework includes a gate valve, 1 NPT sockets for pressure gauge and wash down hose and the option of a steel Swing Check or Duo Check NRV
Performance Data
Consult Monoflo for applications with flows or pressures not shown. Serial or parallel configurations available.
Americas Monoflo NOV, 9700 West Gulf Bank Houston, Texas 77040, USA T. +1 281 272 7700 E. inquire@monoflo.com Monoflo S.A., Ing Huergo 2239 (1842) Monte Grande Pcia. de Buenos Aires, Argentina T. +54 11 4290 9940/50 E. info@monoflo.com.ar Monoflo Canada, 6010 - 53rd Ave Alberta, Lloydminster T9V2T2, Canada T. +1 780 875 5584 E. info.monoflo@nov.com Europe Mono Pumps Ltd, Martin Street, Audenshaw Manchester, M34 5JA, England T. +44 (0)161 339 9000 E. info@mono-pumps.com D.M.I EST, 56, rue du Pont 88300 Rebeuville, France T. +33 (0)3 29 94 26 88 E. dmi-est@dmi-est.fr Australasia Mono Pumps (Australia) Pty Ltd Mono House, 338-348 Lower Dandenong Road Mordialloc, Victoria 3195, Australia T. 1800 333 138 E. ozsales@mono-pumps.com Mono Pumps (New Zealand) Ltd PO Box 71-021, Fremlin Place, Avondale Auckland 7, New Zealand T. +64 (0)9 829 0333 E. info@mono-pumps.co.nz Asia Mono Pumps Ltd, No. 500 YaGang Road Lujia Village, Malu, Jiading District Shanghai 201801, P.R. China T. +86 (0)21 5915 7168 E. monoshanghai@nov.com www.monoflo.com
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-Mining DF Monoflo and PowerDrive are registered trademarks of Mono Pumps Ltd.
Produced on recycled paper
Series A Muncher
Typical Applications
A high torque, low speed grinder for open channel and wet well installations, suitable for the efficient disintegration of solids within a flow.
Capacity
up to 5315 gpm
Pump protection for sewage or sludge pumping Screenings maceration Head of works maceration Industrial effluent conditioning Bio-degradable waste maceration for recycling processing Submersible pump protection
Slow operational speeds Flexible design Lower power consumption Simple construction Standardization Built-in overload protection Individual cutting elements Ease of installation
Lower cutter tip speeds dramatically reduce wear rates. The downtime for cutter replacement is reduced, resulting in lower maintenance costs. Slow speeds also ensure low noise and vibration. Monoflo Munchers can be configured for channel, wet well and pipeline installations. Multiple drive options are available including hydraulic or submersible motors. Cost savings, especially when compared to high speed macerators. Minimal attention and maintenance. Ease of servicing - no special tools or fitting skills required. Reduction in downtime. Interchangeability of components. One set of spares required for all machines. Reduced level of parts inventory. Dimensionally compatible with competitive manufacturers. Prevents serious damage to the Muncher, saving on costly downtime. Cost reduction by having to replace only worn cutting elements. No complex civil foundation work required - can be installed into existing channels.
Performance Data
For guidance in selecting a pump, please contact Monoflo.
Performance Curve For Channels Models up to CA205A - Hi-flow 20 18 16 14 HEAD DROP inches) 12 10 8 6 4 2
15.59 396 13.85 352 12.12 308
CA202A CA203A
CA205A
60
CA215A
0 151 5.94
3.46 88
50
11.88 302
CA210A
5.19
6.92 8.66 10.39 264
132
40
176
220
30
CA206A
DOWNSTREAM HEAD
20
10
0 0 500 1000 1500 2000 CAPACITY (GPM) 2500 3000 3500 4000
Performance Curve For Channel Models CA210 & CA215 - Extra-Hiflow Siderails
70
60
0 151 5.94
50
HEAD DROP (inches)
11.88 302
40
CA210A
30
20
DOWNSTREAM
10
Dimensions
MODEL CA202AA CA203AA CA205AA CA206AA CA210AA A 49 53 59 65 81 B 20 25 31 36 53 C 7 11 17 23 39 D 6 6 6 6 6 E 10 10 10 10 10 MODEL CA202AC CA203AC CA205AC CA206AC CA210AC A 50 54 60 66 82 B 20 25 31 36 53 C 7 11 17 23 39 D 7 7 7 7 7 E 10 10 10 10 10
2.0 hp Motor
5.0 hp Motor
A 50 54 60 66 82 102
B 20 25 31 36 53 73
C 7 11 17 23 39 60
D 6 6 6 6 6 6
E 10 10 10 10 10 10
E 12 7 9 6
3.0 hp Motor
14
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-Series A Flyer Monoflo and Muncher are registered trademarks of Mono Pumps Ltd.
1 1 Nov 2006
The Series A Muncher is a slow speed high torque disintegrator designed to operate in the waste water industry. Further data on material handling and capacities can be found in this document. The Series A Muncher is available in six throat length sizes from 8-60. Throat length refers to the nominal length of the cutter bank. Machine type options are the basic channel, pipeline and upflow, the latter two available in a range of sizes and six power units covering three sizes are available to choose from. IMPORTANT NOTICE ON SAFETY The Series A Muncher is a deceptively powerful machine and could, if misused, be extremely dangerous. It is vitally important that operators and any other personnel likely to be involved with the machines read, and be conversant with, the Operation and Maintenance Instructions prior to working with the machine. The units should only be operated with safety features in accordance with current legislation.
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current BUILD AVAILABILITY
THROAT LENGTHS
1 2 Nov 2006
Dimensions indicated are the nominal openings along the length of the cutter bank and in Muncher terminology are always referred to as throat lengths. The Series A Muncher is available with the following choice of throat lengths. MODEL THROAT LENGTH (inch) CA202 8 CA203 12 CA205 20 CA206 24 CA210 40 CA215 60
STANDARD PACKAGES PIPELINE MODEL 1. MACHINE MODULE Six sizes 2. GEARED MOTOR Three sizes. 3. PIPELINE FLANGES Six sizes. 4. CONTROL PANEL CHANNEL MODEL 1. MACHINE MODULE Six sizes 2. GEARED MOTOR Three sizes. 3. CONTROL PANEL
2
2
1
3
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current BUILD AVAILABILITY
RANGE AVAILABILITY
1 3 Nov 2006
The Series A Muncher range covers all applications where raw sewage, sewage screenings and sludge maceration is involved and is comprised of two basic models; (a) the channel type. (b) the pipeline type. Each basic model has been extended into a range divided into power rating and capacity. (a) There are six channel models covering a capacity range from 0 to 3750gpm using standard hi-flow frames, or 0-5315gpm when using extra hi-flow side frames. (b) There are six pipeline models covering a capacity range from 0 to 2160gpm, throat sizes ranging from 8 to 24, inlet / outlet pipe sizes ranging from 3 to 12. The following table provides data for metric models.
MODEL AND CODE No. CA202N CA202P CA202Q CA203Q CA203R CA205S CA206T CA202A CA203A CA205A CA206A CA210A CA215A MAX. SHAFT SPEEDS 2 hp 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 42 & 69 --3 hp 40 & 66 40 & 66 40 & 66 40 & 66 40 & 66 ----40 & 66 40 & 66 40 & 66 40 & 66 40 & 66 40 & 66 5 hp 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 51 & 83 --PRESSURE DROP (APPROX) PSI 0.27 0.27 0.27 0.40 0.57 0.57 0.57 ------------PIPE DIA Inches 3 4 6 6 8 10 12 ------------THROAT SIZE Inches 8 8 8 12 12 20 24 8 12 20 24 40 60
FLANGES DRILLED All models can be supplied to operate in any orientation. Shaft extensions can be supplied in a range of standard lengths up to a maximum of 10 feet. All models are supplied within standard and essential equipment, a logic programme controller and control panel, with electronics arranged for D.O.L. starting only. All models can be supplied to suit 50-60 Hz three phase supply.
Standard motors are protected to IP55. IP68 (Zone 1) models are available. All IP68 motors include thermistor protection as standard.
Published information other than that marked certified is to be used as a guide only
1 4 Nov 2006
BENEFITS Interchangeability of components. One set of spares only required for all machines. Reduced level of stock holding. Minimal attention and maintenance. Ease of servicing. No special fitting skills required. Reduction in down time. No expensive training required. Reduced wear rates. Down time required less frequently. Reduced power costs. Lower noise levels. Cost Saving Saving on costly down time Reduction in numbers of spares variations. Replacement of only worn cutting elements. Saving in down time. No complex civil foundation work required. New foundation blocks not required.
Simple Construction
Ease of installation
CUTTERS AND SPACERS Standard Series A cutters and spacers are fine blanked 1% Chromium Molybdenum steel. Cutters are hardened to 46-50 HRC, spacers are hardened to 42-46 HRC. It is possible to manufacture in other materials, e.g. stainless steels to special order. SHAFTS Series A shafts are machined from high specification alloy steel hexagonal section. The hexagonal portion is hardened to 55-59 HRC. Ferralium or stainless steel options designed to suit particular duties are available. CASING Standard Series A casings cast iron. Where necessary from a corrosion point of view, stainless steel or gunmetal casings are on option. For the vast majority of applications the cast iron machine is recommended. It is particularly resistant to abrasion and has very good general corrosion resistance. PAINTING All standard machines are painted with two pack acrylic.
Published information other than that marked certified is to be used as a guide only
1 5 Nov 2006
MECHANICAL SEAL The mechanical seal used in the Series A Muncher is a self contained multi-function cartridge design, fulfilling all rotary sealing, static sealing and bearing requirements. FEATURE Stationary Based Design BENEFIT Few moving parts Non oscillating alignment at interface Compensates for shaft deflections Easy installation No adjustment necessary Face loading constant Higher operating pressures Reduced heat build-up Thicker liquid film between faces No maintenance Not prone to clogging Retains flexibility Even face loading Long Life Robust and hard wearing Resistant to abrasion Eliminates possibility of shear Reduced bending torque due to clamping forces on assembly Robust seal High Spec Stainless Steel for max. corrosion resistance
MECHANICAL SEAL DETAIL
A
Self Centring and Adjusting Slurry Protected Springs Springs out of Product Multi Springs Tungsten Carbide Face Materials
Published information other than that marked certified is to be used as a guide only
A-A
1 6 Nov 2006
The motor control panels have been designed to provide all the necessary control functions including automatic reversal on overload, and shutdown after 3 reversals. The control circuit is usually 110v A.C. but can be any voltage generated either from within the panel or from an external supply if the unit is to be fitted in a large control panel. The control panels can be provided in 3 basic forms 1. 2. 3. A single compartment unit containing all control equipment including contactor, fuses to IEC269 thermal overloads, and programmable electronics to monitor motor power and supply all logic functions. Also push buttons for hand operation and indicating lamps. A chassis consisting of all necessary fuses, contactors, overloads, transformers, logi-control unit and terminals for the customer to connect his own push buttons lamps etc. Logi-control unit with transformer and CT, to be fitted into customer control panel.
The control unit can be supplied to control the following. 1. 2. 3. 4. A single motor Muncher. A 2 motor Muncher. A single motor Muncher and Pump. A single motor Muncher and Discreen.
The unit requires 3 phase input. One motor leg is taken through a CT. The output from this and the 3 phase are used by the electronics to monitor motor power. If the unit is programmed as a Munchpump unit, the pump is prevented from starting until the Muncher starting load has reduced to less than 150% full load current. The unit can be used to monitor any 3 phase supply from 200v A.C. to 550v A.C. The unit can be arranged to monitor 1 or 2 A.C. motors from 1hp to 30hp.
Published information other than that marked certified is to be used as a guide only
1 7 Nov 2006
The control unit has been designed and programmed to measure motor power by taking the current from 1 motor phase and using the other 2 phases as a voltage reference, or in the case of a single phase supply by taking the current in the leg of the motor and using the neutral as a voltage reference. In monitoring the Muncher load, the motor power curve is used in preference to the current curve, as this power curve closely reflects the torque characteristics. In this way the Muncher may be allowed to develop close to 3 times its full load torque momentarily on demand without a motor 'trip' situation. This maximizes the work potential of the Muncher without putting at risk the integrity of the internal mechanical components. If the current curve was used it would be necessary to reduced the maximum torque to approximately 1.5 times full load torque. The motor trip point is not a simple point that represents anything over 100% F.L.P. but is a curve that will permit limited operation of approximately 0.5 seconds at 300% - 6 seconds at 150% and 30 seconds at 105% before 'trip'. This curve is designed to allow the Muncher to work as hard as possible but still give maximum protection. When the Muncher has become overloaded the unit will stop and after a delay of approximately 1 second to allow the Muncher to stop rotating go in reverse for approximately 2 seconds to clear anything that is stuck in the Muncher teeth, again there is a 1 second delay before the Muncher resumes going forward. If there are 3 reversals in less than 60 seconds the control unit assumes this to be that same blockage that it can not clear and trips out giving an alarm. The electronics will monitor the motor power regardless of motor direction, and will trip out if overload conditions occur. They also monitor the motor power during starting. If the motor takes start or stall power for more than approximately 2 seconds, the electronics will activate trip out. To restart, it is first necessary to press the stop/start button. There is a reverse button on the control panel, this allows for driving the Muncher in reverse for as long as the button is pressed. The unit can be run in 3 ways. 1. Hand Control This allows the unit to be started and stopped by a push button. (Load monitoring is not carried out in this mode) 2. Auto Control This allows the unit to be started and stopped by a set of volt free contacts from level controls or other equipment. 3. Reverse Button This is to allow manual reversal of the Muncher to clear a blockage. This function does not latch and the unit will only run in reverse for the time the reverse button is pressed, and will stop when it is released. The automatic monitoring of the Muncher load is operative under all working conditions
Published information other than that marked certified is to be used as a guide only
1 8 Nov 2006
CUTTERS For standardization of manufacture, cutter width (thickness) variations are kept to a minimum. 0.31 and 0.22 are standard tooth widths. The cutter major diameter is 4.72. If a wider shred is required, it is possible to stack the cutters adjacent to each other in pairs, in triplicate, or in quadruplicate arrangements. These are denoted 1x1, 2x2, 3x3, and 4x4 stacking. STACKING PATTERNS
'A'
123456
1,2,3,4,5 & 6
'IN-LINE CUTTER' STACKING View on arrow 'A' The cutters are stacked in such a way that all teeth are in-line as shown.
'A'
VIEW ON 'A'
123456
1,3,5
'OFF-SET' 2,4,6 STACKING View on arrow 'A' The cutters are stacked so that each alternate cutter is in-line, as shown.
VIEW ON 'A'
'A'
123456
'SPIRAL' STACKING
6
5
4 3 2 1
View on arrow 'A' Each cutter is off-set at an equal angle along the throat to give a sprial effect as shown.
VIEW ON 'A'
Published information other than that marked certified is to be used as a guide only
1 9 Nov 2006
SPACER
Published information other than that marked certified is to be used as a guide only
1 10 Nov 2006
CUTTER ACTION Raw sewage contains widely differing materials that need a combination of processing to adequately cope with materials as diverse as discarded panti-hose, alloy cans, plastic wrappers and sundry rubber goods. The Muncher was specifically designed to cope with modern sewage flows and its rogue contents. The differential speed of the cutter stacks pull and tease apart fibrous material whilst the leading edge and sides of the cutter teeth crop and shear plastic into small strips. The circumferential land of the cutter crushes friable or brittle material a unique combination in the field of waste processing.
CRUSH
SHEAR
CROP
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current CODING SHEET
Features Description Cast Iron Body Material Product Mark No. Stainless Steel ** Gun Metal ** Series A Muncher 1988 200mm (8") 300mm (12") Throat Size 500mm (20") 600mm (24") 1000mm (40") 1500mm (60") Basic (Channel Type) Pipeline 80 N.B. to BS4504 Pipeline 100 N.B. to BS4504 Pipeline 150 N.B. to BS4504 Pipeline 200 N.B. to BS4504 Pipeline 250 N.B. to BS4504 Pipeline 300 N.B. to BS4504 Machine Type and Flange Bore (Metric Flanges Drilled to BS4504 PN16 and Imperial Flanges Drilled to ANSI B16.5 Class 150) Upflow 80 N.B. to BS4504 Upflow 100 N.B. to BS4504 Upflow 150 N.B. to BS4504 Upflow 200 N.B. to BS4504 Pipeline 3" N.B. ANSI Pipeline 4" N.B. ANSI Pipeline 6" N.B. ANSI Pipeline 8" N.B. ANSI Pipeline 10" N.B. ANSI Pipeline 12" N.B. ANSI Upflow 3" N.B. ANSI Upflow 4" N.B. ANSI Upflow 6" N.B. ANSI Upflow 8" N.B. ANSI Build Option Cutter No. of Teeth Thickness Material (Cutters) Oblique Field Variation Side Rail Variation Typical Code High Flow Extra High Flow C A 2 0 2 B Refer to build options on pages 12 & 13 CAM 7 5.5mm (0.2165") 8.0mm (0.3150") Chromium Molybdenum Steel
1 11 Nov 2006
Basic Code 1 C S G A 2 0 0 0 0 1 1 2 3 5 6 0 5 A B C D E F G H J K L N P Q R S T U V W Y * T 7 A B 2 / V 5 5 * T 7 B 2 / 1 2 3 4 5 6 7 8 9 10 11 12
Variation 13 14 15
A 2 8 2
R 8 4 3
** Note:
Stainless Steel and Gun Metal construction available with high flow side rails only "X" in any column denotes a special variation.
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current BUILD OPTIONS
ADAPTOR STOOL CODE GEARBOX MANUFACTURER NORD (IP55) G NORD (IP68) MOTOVARIO (IP55) MOTOVARIO (IP55) NORD (IP55) H NORD (IP68) MOTOVARIO (IP55) J K L M NORD (IP55) NORD (IP68) SUMITOMO (IP55) SUMITOMO (IP55) SUMITOMO (IP55)
1 12 Nov 2006
GEARBOX/MOTOR REFERENCE SK30F - 90L4 SK30F - IEC 100 CHF052F-T90L4 CHF052F-T100L4 SK33F - 100L4 SK33F - IEC 132 CHF062F-T112M4 SK42F - 112M4 SK42F - IEC 160 VM3115 / VM4115 VM3140 VM3160
HP RATING 2hp 2hp 2hp 3hp 3hp 3hp 5hp 5hp 5hp 2hp 3hp 5hp
Published information other than that marked certified is to be used as a guide only
1 13 Nov 2006
ADAPTOR STOOL PART NO. CD A02A 1722 CD A02A 1721 CD A02A 1720 CD A02A 1701 CD A02C 1701 CD A02B 1701
MUNCHER COUPLING PART NO. MS A02A 2600 MS A02A 2601 MS A02A 2601 MS A02A 2600 MS A02A 2601 MS A02A 2601
GEAR COUPLING PART NO. MS A02G 2626 MS A02A 2655 MS A02B 2660 MS A02A 2627 MS A02C 2627 MS A02B 2627
GEARBOX FLANGE / P.C.D. (mm) 250 / 215 250 / 215 250 / 215 210 / 180 260 / 230 340 / 310
Published information other than that marked certified is to be used as a guide only
1 14 Nov 2006
1 15 Nov 2006
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current GENERAL SPECIFICATION
1 16 Nov 2006
The sewage (or sludge) Grinder/Disintegrator shall be of the twin shaft, slow speed, high torque design. A selection of machine frame lengths will be provided for using varied siderail lengths. The machine will be available as an open channel unit or, fitted with pipe flanges, as a pipeline unit to fit a variety of standard pipework between 3 and 12 nominal bore. The shaft centers will not exceed 4, and the speed of rotation will not exceed 85rpm. Each shaft is to be fitted with identical interleaving cutters and spacers, the cutter having 7 teeth. The tooth profile is of CAM design whereby all teeth are parallel to the shaft centerline. An alternate cutter design is available for the precipitation hardening stainless steel version, in this case the profile shall be of equal thrust offset tooth design, one tip pitched parallel to the shaft centerline, other teeth at alternative angles of 30 degrees to the centerline of the shaft. In this design the cutter will have either 5 or 7 teeth dependant on thickness. Each shaft shall be supported at each end within identical cast housings by ball bearings, protected by mechanical seals. The seals are to be located in stainless steel cartridges. Drive to the machine will be provided to one shaft by a geared motor. Drive will be divided between shafts using spur gears of case hardened steel. The machine is to be complete with a PLC based control system and provide the following functions: 1. To operate in normal on/off mode. 2. To provide sufficient overload protection. 3. To provide automatic jam clearance reversal action and resume to normal duty. 4. To activate automatic shutdown after three jams within 60 seconds. The logic must be able to differentiate between a locked rotor full overload requiring instant reversal and an allowable periodic low level overload allowing an ongoing running period before reversal mode is engaged.
ITEM SHAFTS CUTTERS & SPACERS CASING MECHANICAL SEALS DRIVE Description Shall be constructed from high specification alloy steel hexagonal stock, with a 55-59 HRC minimum surface hardness. Shall be of chromium/molybdenum alloy steel, hardened, tempered and ground, having a 46-50 HRC minimum surface hardness. Shall be of cast iron, stainless steel, or gunmetal dependent on application. Will have a maximum working pressure in excess of 29 PSI, having faces of solid tungsten carbide and be of a cartridge design with integral bearings and seals. Will be of the integral motor/gearbox speed reducer type close coupled to the main grinder module, by a coupling capable of transmitting full torque output of the gearbox under a stall condition. All standard machines are painted with two pack acrylic.
PAINTWORK
Published information other than that marked certified is to be used as a guide only
2 1 Nov 2006
Published information other than that marked certified is to be used as a guide only
2 2 Nov 2006
NB. Similarly it is essential that all enquiries for open channel Series A Munchers be investigated fully to identify the duty conditions and aid cutter type selection.
FLOW INDUCED BY AERATOR
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
1. Identify the material to be handled: a) Raw sewage b) Raw sewage with high rag and solids content. c) Sludge d) Sludge with high rag and solids content e) Screenings with wash water f) Sludge with fine processed particle size 2. Determine model required: a) Pipeline b) Channel 3.
2 3 Nov 2006
Determine feed type: a) Pumped b) Gravity Determine dry solids content (if sludge or slurry) a) 0% to 8% Determine maximum flow rate. Determine the downstream head. (Channel models)
4. 5. 6.
CALCULATING FLOWRATES Sewage discharge is seldom constant and daily flow rates cannot be selected on the basis of total volume divided by 24 hours. To establish a viable throughput rate the total calculated volume for a 24 hour day should be averaged over a 16 hour period. The flow rate is usually identified in terms of total population or type of premises for which sewage facilities are required. A typical domestic water consumption figure is 48 gallons per person per day. The figures for types of premises are given overleaf. Calculation 1 No. of persons x 48 16 x 60 Calculation 2 In terms of population: Daily Flow Rate GPM In terms of premises: Daily Flow Rate GPM
Due to habits common to a civilized society peak flow conditions occur. It is this fact which when related to the particular requirements which determines product selection. The type of sewerage system to be used will have an effect on the peak flowrate for which a weighting factor may be used. This can be one of three types. System Type Combined system Separate system Partially separate system Factor 6 3 3
Maximum flow rate or peak flow can now be established by multiplying the result of the relevant calculation (1 or 2) by the appropriate System factor.
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
Example
2 4 Nov 2006
Based on total population and combined system Maximum Flow Rate GPM
No. of persons x 48 x 6 16 x 60
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
CALCULATING DOWNSTREAM HEAD
2 5 Nov 2006
'Downstream head' is the theoretical height of the existing flow through a clear channel of the operational width of the Series A Muncher (12). If Q = AV where A is the cross sectional area and V the velocity, Q = whV where w is the channel width and h is the head height h = QwV The table below shows open channel head (h) values for volumetric flowrate (Q) values based on a standard gravity flowrate of 3.3ft/s and a 12 channel width. Variations in channel surface and gradient also affect this conversion. Q (gpm) 110 220 440 880 1760 3520 h (inches) 0.9 1.8 3.5 7.0 14 28
With the preceding information established i.e. material, model, feed, solids content, maximum flow rate and downstream head, the following pre-selection table can now be used to identify the appropriate selection chart number and subsequently the correct unit. PRE-SELECTION CHART
MATERIALS TO BE HANDLED MODEL PIPELINE RAW SEWAGE PIPELINE CHANNEL FEED PUMPED GRAVITY GRAVITY gal/min CAPACITY Chart No. 0-572 6 0-969 7 0-1541 8 0-2157 9 REFER TO MONOFLO 0-440 1 0-594 2 0-2730 3 0-3742 4 0-572 SLUDGE (FOR HIGH RAG/DRY SOLIDS CONTENT CAPACITIES ARE REDUCED) PIPELINE PUMPED 0-969 0-1541 0-2157 6 7 8 9
PIPELINE GRAVITY REFER TO MONOFLO CHANNEL GRAVITY CHANNEL GRAVITY SCREENINGS WITH WASH WATER CHANNEL GRAVITY 0-550 5 FIGURES ARE MAX. VALUES BASED ON 0% RAW SEWAGE. FOR HIGH RAG/SOLIDS CONTENT REFER TO CURVES
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
Chart No. 1 2 3 4 5 6 7 8
2 6 Nov 2006
Contents Channel -CA202, CA203, CA205 - Hi-flow Channel -CA206, CA210, CA215 - Hi-flow Channel -CA206, CA210, CA215 Extra Hi-flow Channel -CA203, CA205, CA206 - Screenings Liquor Pipeline - CA202 Pipeline - CA203 Pipeline - CA205 Pipeline - CA206
Example 1 Material Handled Sludge (High Solids Content) Model Pipeline Feed Pumped Solids Content 6% Max. Flow 198gpm From pre-selection table, Chart 6 is identified. From Chart 6, locating 6% solids content against 198gpm capacity, unit CA202C is identified and a Pressure differential of 1.30 PSI is indicated. Example 2 Material Handled Hospital outlet raw sewage (High Rag Content) Model Pipeline Feed Pumped Solids Content 6% Max Flow 1057gpm From pre-selection table, Chart 8 and unit CA205F are identified. However 1057gpm and 6% DS do not converge within the Munchers operating pressure. In this case, Chart 9 should be consulted. From Chart 9, unit CA206G is identified and the convergence of 1057gpm and 6% DS indicate a Pressure differential of 4 PSI. Example 3 Material Handled Raw sewage Model Channel Feed Gravity Max Flow 440gpm Downstream head 3.5 From pre-selection table, Chart 2 is identified. From Chart 2, at 440gpm, unit CA205A Hi-Flow is identified. Where 440gpm and the 3.4 downstream head curve converge, the Head Drop may be read off the vertical axis to be approx. 12.
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 7 Nov 2006
From chart 3, unit CA206A is also suited to this application. Using the above method gives a Head Drop of approx. 16. (This indicates the degree of operational overlap between model sizes) NOTE: REQUIRED MOTOR POWERS ARE GIVEN ON EACH CHART ALL DOWN RATING OF UNITS FOR VARIOUS APPLICATIONS HAVE BEEN APPLIED, NO FURTHER CALCULATIONS ARE NECESSARY. CARE SHOULD ALSO BE TAKEN TO ENSURE THAT THE COMBINED DOWNSTREAM HEAD AND HEAD DROP (UPSTREAM HEAD) DOES NOT EXCEED THE DEPTH OF THE CHOSEN MODEL OF MUNCHER AND DOES NOT EXCEED THE OVERFLOW LEVEL OF THE SYSTEM.
Published information other than that marked certified is to be used as a guide only
STATUS
20
CA205A
18 0
1.73 44 3.46 88
CA203A
Current
16
14
12
5.19
132
10 176
8.66
6.92
8 220
10.39 264 12.12 308 13.85 352 15.59 396
CA202A
SELECTION PROCEDURE
DOWNSTREAM HEAD
PAGE
DATE
SECTION
100
Published information other than that marked certified is to be used as a guide only
Nov 2006
STATUS
70
Current
60
CA215A
0 151 5.94
50
11.88 302
CA210A
40
17.83 453 23.77 604 29.72 755 35.66 906 41.61 1057 47.55 1208 53.50 1359
1000 1500 2000 CAPACITY (GPM) 2500 3000 3500 4000 DOWNSTREAM HEAD
30
CA206A
SELECTION PROCEDURE
20
PAGE
DATE
SECTION
10
500
Published information other than that marked certified is to be used as a guide only
Nov 2006
STATUS
Performance Curve For Channel Models CA210 & CA215 - Extra-Hiflow Siderails
70
CA215A
Current
60 0 151 5.94
50
11.88 302
CA210A
40
30
SELECTION PROCEDURE
20
PAGE
DATE
SECTION
10
1000
Published information other than that marked certified is to be used as a guide only
10 Nov 2006
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 11 Nov 2006
SCREENINGS LIQUOR
4%
5%
Published information other than that marked certified is to be used as a guide only
100
0% CAPACITY (GPM)
1%
2%
SOLIDS CONTENT
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 12 Nov 2006
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 13 Nov 2006
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 14 Nov 2006
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
2 15 Nov 2006
Published information other than that marked certified is to be used as a guide only
MACHINE TYPE Muncher MODEL RANGE Series A STATUS Current SELECTION PROCEDURE
FURTHER SELECTION CRITERIA
2 16 Nov 2006
To complete the machine specification code number and finalize the selection it is necessary to establish cutter details. a) Cutter Profile and Diameter Series A cutters are 4.72 diameter with a saw tooth. b) Number of Teeth Series A cutters have 7 teeth. c) Cutter Width There are two cutter widths available for the Series A machines. i) 0.3 wide used for raw sewage/sludge (channel and pipeline models), denoted 'B'. ii) 0.2 wide used for sludge and fine maceration, denoted 'A'. d) Cutter Material The cutter material is Chromium Molybdenum Steel, denoted '2' as standard. Enquiries concerning variations outside the above parameters should be referred to Monoflo. The average particle sizes expected to be produced using the available cutters are as follows:0.3 wide cutter - 0.3 x 0.4 0.2 wide cutter- 0.2 x 0.4 Please note that because of the diverse nature of the waste solids being processed, the above particle sizes are an average to be used only as a guideline.
Published information other than that marked certified is to be used as a guide only
2 17 Nov 2006
CIVIL ARRANGEMENTS-SINGLE MUNCHER WITH BYPASS MODEL CA202A CA203A CA205A CA206A CA210A CA215A DIMENSION 'X' (inches) 6.9 11.4 17.3 23.0 39.3 59.0
Published information other than that marked certified is to be used as a guide only
2 18 Nov 2006
CIVIL ARRANGEMENTS-MULTIPLE MUNCHERS WITH BYPASS Installation 'A' is the preferred arrangement to installation 'B'. Either may be extended to house double, triple or greater Muncher configurations. Elevation as for Single Muncher applies.
Published information other than that marked certified is to be used as a guide only
2 19 Nov 2006
MOUNTING FRAME The mounting frame is a fabricated structure of steel plate and section. It is secured into the sewage channel and the Muncher is lowered into position. No additional fixings are required. Frames can be mounted side by side to accommodate multiple configurations.
Published information other than that marked certified is to be used as a guide only
2 20 Nov 2006
Published information other than that marked certified is to be used as a guide only
2 21 Nov 2006
Published information other than that marked certified is to be used as a guide only
2 22 Nov 2006
Published information other than that marked certified is to be used as a guide only
2 23 Nov 2006
Published information other than that marked certified is to be used as a guide only
2 24 Nov 2006
SLUDGE TREATMENT
Wherever possible install Series A Muncher for pipeline duties horizontal with inlet at bottom. This helps reduce wear on mechanical seals, equalizes cutter usage and wear rate and allows any object that may stall machine to drop back out of the unit into the trash trap.
ISOLATING VALVE
TRASH TRAP
Published information other than that marked certified is to be used as a guide only
2 25 Nov 2006
Sludge Treatment
MUNCHER
PUMP
Published information other than that marked certified is to be used as a guide only
SLUDGE TANK
Current
SLUDGE DEPOSITORY
MUNCHER
INSTALLATION GUIDELINES
PUMP
PAGE DATE
SECTION 2
Published information other than that marked certified is to be used as a guide only
26
As illustrated, the sludge is dropped into the reception tank, then passes through the Muncher for fine maceration, after which the sludge is then pumped away for treatment.
Nov 2006
2 27 Nov 2006
Final Effluent Tank Monoflo Pump Screen Flume Muncher Submersible Pump Valve Station
Published information other than that marked certified is to be used as a guide only
6.
1. 2. 3. 4. 5.
TR Muncher
Typical Applications
A high torque, low speed grinder for pipeline installations, suitable for the efficient disintegration of solids within a flow.
Capacity up to 1937 gpm Pump protection for sewage or sludge pumping Screenings maceration Sludge/slurry homogenization Industrial effluent conditioning Bio-degradable waste
Top mechanical seal Cantilever design Angled cutter stack design Pull back cutter stack Built-in trash trap Slow operational speeds High torque grinder Lower power consumption Standardization Built-in overload protection
Prevents leakage of product and grit build up, reducing mechanical seal wear. Eliminates the need for lower seals and bearings, reducing downtime and repair cost. Angled cutter stack rejects hard materials reducing the risk of damage to the cutter teeth. Allows removal without disturbing pipeline. Catches any rejected material, which can then be removed through the clean-out ports. Lower cutter tip speeds dramatically reduce wear rates. The downtime for cutter replacement is reduced, resulting in lower maintenance costs. Slow speeds also ensure low noise and vibration. Gives high torque capability, enabling the machine to handle a wide range of solids. Cost savings, especially when compared to high speed macerators. Interchangeability of components. One set of spares required for all machines. Reduced level of parts inventory. Dimensionally compatible with competitive manufacturers. Prevents serious damage to the Muncher, saving on costly downtime.
Performance Data
MONOFLO F lo w C h aracteristics fo r M o d el C T 203 T R M u n ch er
CT203
CT205
MONOFLO
7.00
6.00
8% D S
6% D S
4% D S
2% D S
0% D S
10% D S
8% D S
6% D S
4% D S
2% D S
0% D S
5.00
P re s s u re D iff (P S I)
4.00
4.00
3.00
C T 203Q (6")
2.00
3.00
C T 205S (10")
2 HP 3HP 5 HP
2 HP
2.00
C T 203P (4")
1.00
3HP 5 HP
1.00
0.00 0 100 200 300 400 500 600 700 800 900 1000 1100 1200
C a p a c ity (U S G P M )
C a p a c ity (U S G P M )
Dimensions
MODEL CT203P CT203Q CT203R CT205S CT205T A* 4 6 8 10 12 B 15 15 15 15 15 C 40 40 40 47 47 D 8 9 10 11 13 E 1 1 1 1 1 F 19 21 23 27 31 G 16 16 16 18 18 H 5 6 8 8 10 I 6 2 1 1 -1 J 14 14 14 16 16 K 14 14 14 20 19 L 9 11 14 16 19 MODEL CT203P CT203Q CT203R CT205S CT205T A* 4 6 8 10 12 B 16 16 16 16 16 C 45 46 46 52 52 D 8 9 10 11 13 E 1 1 1 1 1 F 19 21 23 27 31 G 16 16 16 18 18 H 5 6 8 8 10 I 7 4 3 3 2 J 14 14 14 16 16 K 14 14 14 20 19 L 9 11 14 16 19 2.0 hp Motor 3.0 & 5.0 hp Motor
* 150# ANSI flat face flange. All dimensions in inches and for guidance only.
21.3
Published information other than that marked CERTIFIED does not extend any warranty or representation, expressed or implied, regarding these products. Any such warranties or other terms and conditions of sales and products shall be in accordance with Monoflos standard terms and conditions of sale, available on request. Monoflo products are marketed outside North America under the mark Mono. Literature reference: MFI-TR Flyer Monoflo and Muncher are registered trademarks of Mono Pumps Ltd.
3 1 Nov 2006
The TR Muncher is a slow speed high torque disintegrator designed to operate in the waste water industry. Further data on material handling and capacities can be found in this document. The TR Muncher is available in two throat lengths, sizes 12 and 20. Throat length refers to the nominal length of the cutter bank. Machine type is a pipeline device available in a range of 10 pipelines covering 5 sizes and 6 power units covering 3 sizes are available to choose from. Key design features are; a one piece bearing housing cantilevered shafts 250 inclined cutter stacks with trash trap Pull-back concept stack removal All these features combine to provide a simple, inexpensive construction package, whilst maintaining the exceptionally rugged and highly efficient characteristics of the Muncher range. IMPORTANT NOTICE ON SAFETY The TR Muncher is a very powerful machine and could, if misused, be extremely dangerous. It is vitally important that operators and any other personnel likely to be involved with the machines read, and be conversant with, the Operation and Maintenance Instructions prior to working with the machine. The units should only be operated with safety features in accordance with current legislation.
Published information other than that marked certified is to be used as a guide only
3 2 Nov 2006
Dimensions indicated are the nominal openings along the length of the cutter bank and in Muncher terminology are always referred to as throat lengths. The TR Muncher is available with the following choice of throat lengths. MODEL THROAT LENGTH (INCHES) STANDARD PACKAGES
1. MAIN PIPELINE BODY 5 METRIC SIZES 5 IMPERIAL SIZES 2. GEARED MOTOR 3 METRIC SIZES 3 IMPERIAL SIZES 3. CONTROL PANEL
CT203 12
CT205 20
Published information other than that marked certified is to be used as a guide only
3 3 Nov 2006
The TR Muncher range covers all applications where raw sewage, sewage screenings and sludge maceration is involved. The range is divide into two throat sizes, then five pipe sizes and three motors are available. The following tables indicate the TR Muncher capacities in GPM and range availability.
IMPERIAL MACHINE CODE PIPE N/B (ANSI) CT203P 4" CT203Q 6" CT203R 8" CT205S 10" CT205T 12"
TR Munchers are designed only to operate in the horizontal position where the best use can be made of its unique design. All models supplied with standard and essential equipment, a logic programme controller and control panel, with electronics arranged for D.O.L. starting only. All models can be supplied to suit 50-60 Hz three phase supply.
Standard motors are protected to IP55. IP68 (Zone 1) models are available. All IP68 motors include thermistor protection as standard.
Published information other than that marked certified is to be used as a guide only
3 4 Nov 2007
BENEFITS Interchangeability of components. One set of spares only required for all machines. Reduced level of stock holding. Minimal attention and maintenance. Ease of servicing. No special fitting skills required. Reduction in down time. No expensive training required. Reduced wear rates. Down time required less frequently. Reduced power costs. Lower noise levels. Cost Saving Saving on costly down time Reduction in numbers of spares variations. Replacement of only worn cutting elements. Saving in down time. No complex civil foundation work required. New foundation blocks not required.
Simple Construction
Ease of installation
CUTTERS AND SPACERS Standard TR Muncher cutters and spacers are; a) investment cast 1% Chromium Molybdenum steel or b) 4140 Plate Cutters are hardened to 45-50 HRC, spacers are hardened to 41-46 HRC. It is possible to manufacture in other materials, e.g. stainless steels to special order. SHAFTS TR Muncher shafts are machined from 4140 alloy steel hexagonal section. The hexagonal portion is hardened to 55-59 HRC. Ferralium or stainless steel options designed to suit particular duties are available. CASING TR Muncher casings cast iron. Where necessary from a corrosion point of view, stainless steel is an option. For the vast majority of applications the cast iron machine is recommended. It is particularly resistant to abrasion and has very good general corrosion resistance. PAINTING All standard machines are painted with two pack acrylic.
Published information other than that marked certified is to be used as a guide only
3 5 Nov 2006
MECHANICAL SEAL The mechanical seal used in the TR Muncher is a self contained multi-function cartridge design, fulfilling all rotary sealing, static sealing and bearing requirements. FEATURE Stationary Based Design BENEFIT Few moving parts Non oscillating alignment at interface Compensates for shaft deflections Easy installation No adjustment necessary Face loading constant Higher operating pressures Reduced heat build-up Thicker liquid film between faces No maintenance Not prone to clogging Retains flexibility Even face loading Long Life Robust and hard wearing Resistant to abrasion Eliminates possibility of shear Reduced bending torque due to clamping forces on assembly Robust seal High Spec Stainless Steel for max. corrosion resistance
Self Centring and Adjusting Slurry Protected Springs Springs out of Product Multi Springs Tungsten Carbide Face Materials
Published information other than that marked certified is to be used as a guide only
3 6 Nov 2006
NO LOWER BEARINGS/SEALS
CONVENTIONAL GRINDER
Published information other than that marked certified is to be used as a guide only
3 7 Nov 2006
The machine has been designed to allow removal (pull-back) of the cutter assembly for servicing and maintenance without having to disturb the pipeline arrangement. If required, a temporary screen can then be fitted and the system run whilst work on the cutter assembly is carried out.
MAINTENANCE PERIOD SCREEN For use where it is essential that the system/process is operational as soon as possible, an optional extra of a small bar screen which fits into this main body is available. Screen size is 0.60.
Published information other than that marked certified is to be used as a guide only
3 8 Nov 2006
The cutter stack is inclined at 25 from the vertical axis to allow any unbreakable solids to drop clear of the cutters into the trash trap on reversal of the cutter stacks. The solids can then be manually removed once the machine has been isolated (mechanically & electrically). The unique internal trash trap built into main body of the machine (patent pending), has access covers placed on either side for easy clean out. Access coverplates drilled to suit standard NP16 2 diameter flange to allow hosetail or similar to be fitted for flushing exercise when required.
25
TRASH TRAP
Published information other than that marked certified is to be used as a guide only
3 9 Nov 2007
DRIVEN SHAFT
HEXAGONAL SECTION
DETAILS Shaft size: Bearing seat dia: Material Code: Hardness: 2 Hexagonal section Front: 60 Rear: 50 LF/H 55-59 HRC (Hexagon Section)
The operational speed of the shafts closely matches the ideal 12:10 ratio as follows:Motor Size 2 1.5 HP 3 2.2 HP 5 4.0 HP Drive Shaft RPM 72 65 65 Driven Shaft RPM 61 55 55 Torque @ Drive Shaft 147 lbf.ft 238 lbf.lt 434 lbf.ft
Note: Locknuts/bolts are self-tightening Drive Shaft is tapped M16 x 0.1 pitch right hand thread Driven Shaft is tapped M16 x 0.1 pitch left hand thread The motor control panels have been designed to provide all the necessary control functions.
Published information other than that marked certified is to be used as a guide only
3 10 Nov 2006
S P
Output Shaft/Bore 45 45 45
The direction of rotation of the output shaft, when viewed from above is clockwise when. (For IP55 only).
Published information other than that marked certified is to be used as a guide only
3 11 Nov 2006
The motor control panels have been designed to provide all the necessary control functions including automatic reversal on overload, and shutdown after 3 reversals. The control circuit is usually 110v A.C. but can be any voltage generated either from within the panel or from an external supply if the unit is to be fitted in a large control panel. The control panels can be provided in 3 basic forms 1. 2. 3. A single compartment unit containing all control equipment including contactor, fuses to BS88 thermal overloads, and programmable electronics to monitor motor power and supply all logic functions. Also push buttons for hand operation and indicating lamps. A chassis consisting of all necessary fuses, contactors, overloads, transformers, logi-control unit and terminals for the customer to connect his own push buttons lamps etc. Logi-control unit with transformer and CT, to be fitted into customer control panel.
The control unit can be supplied to control the following. 1. 2. 3. 4. A single motor Muncher. A 2 motor Muncher. A single motor Muncher and Pump. A single motor Muncher and Discreen.
The unit requires 3 phase input. One motor leg is taken through a CT. The output from this and the 3 phase are used by the electronics to monitor motor power. If the unit is programmed as a Munchpump unit, the pump is prevented from starting until the Muncher starting load has reduced to less than 150% full load current. The unit can be used to monitor any 3 phase supply from 200v A.C. to 550v A.C. The unit can be arranged to monitor 1 or 2 A.C. motors from 1hp to 30hp.
Published information other than that marked certified is to be used as a guide only
3 12 Nov 2006
The control unit has been designed and programmed to measure motor power by taking the current from 1 motor phase and using the other 2 phases as a voltage reference, or in the case of a single phase supply by taking the current in the leg of the motor and using the neutral as a voltage reference. In monitoring the Muncher load, the motor power curve is used in preference to the current curve, as this power curve closely reflects the torque characteristics. In this way the Muncher may be allowed to develop close to 3 times its full load torque momentarily on demand without a motor 'trip' situation. This maximizes the work potential of the Muncher without putting at risk the integrity of the internal mechanical components. If the current curve was used it would be necessary to reduced the maximum torque to approximately 1.5 times full load torque. The motor trip point is not a simple point that represents anything over 100% F.L.P. but is a curve that will permit limited operation of approximately 0.5 seconds at 300% - 6 seconds at 150% and 30 seconds at 105% before 'trip'. This curve is designed to allow the Muncher to work as hard as possible but still give maximum protection. When the Muncher has become overloaded the unit will stop and after a delay of approximately 1 second to allow the Muncher to stop rotating go in reverse for approximately 2 seconds to clear anything that is stuck in the Muncher teeth, again there is a 1 second delay before the Muncher resumes going forward. If there are 3 reversals in less than 60 seconds the control unit assumes this to be that same blockage that it can not clear and trips out giving an alarm. The electronics will monitor the motor power regardless of motor direction, and will trip out if overload conditions occur. They also monitor the motor power during starting. If the motor takes start or stall power for more than approximately 2 seconds, the electronics will activate trip out. To restart, it is first necessary to press the stop/start button. There is a reverse button on the control panel, this allows for driving the Muncher in reverse for as long as the button is pressed. The unit can be run in 3 ways. 1. Hand Control This allows the unit to be started and stopped by a push button. (Load monitoring is not carried out in this mode) 2. Auto Control This allows the unit to be started and stopped by a set of volt free contacts from level controls or other equipment. 3. Reverse Button This is to allow manual reversal of the Muncher to clear a blockage. This function does not latch and the unit will only run in reverse for the time the reverse button is pressed, and will stop when it is released. The automatic monitoring of the Muncher load is operative under all working conditions
Published information other than that marked certified is to be used as a guide only
3 13 Nov 2006
CUTTERS For standardization of manufacture, cutter width (thickness) variations are kept to a minimum. 0.3 and 0.2 are standard tooth widths. The cutter major diameter is 5. If a wider shred is required, it is possible to stack the cutters adjacent to each other in pairs, in triplicate, or in quadruplicate arrangements. These are denoted 1x1, 2x2, 3x3, and 4x4 stacking. STACKING PATTERNS
'A'
123456
1,2,3,4,5 & 6
'IN-LINE CUTTER' STACKING View on arrow 'A' The cutters are stacked in such a way that all teeth are in-line as shown.
'A'
VIEW ON 'A'
123456
1,3,5
'OFF-SET' 2,4,6 STACKING View on arrow 'A' The cutters are stacked so that each alternate cutter is in-line, as shown.
VIEW ON 'A'
'A'
123456
6
'SPIRAL' STACKING
5
4 3 2 1
View on arrow 'A' Each cutter is off-set at an equal angle along the throat to give a sprial effect as shown.
VIEW ON 'A'
Published information other than that marked certified is to be used as a guide only
3 14 Nov 2006
CUTTER STACKING
QUANTITIES
MODEL CT203 0.3 0.2 CT205 0.3 THICKNESS 0.2 ITEM CUTTER SPACER CUTTER SPACER CUTTER SPACER CUTTER SPACER DRIVE SHAFT 22 23 15 16 36 36 26 25 DRIVEN SHAFT 21 23 15 16 33 37 25 26
Published information other than that marked certified is to be used as a guide only
3 15 Nov 2006
CUTTER ACTION Raw sewage contains widely differing materials that need a combination of processing to adequately cope with materials as diverse as discarded panti-hose, alloy cans, plastic wrappers and sundry rubber goods. The Muncher was specifically designed to cope with modern sewage flows and its rogue contents. The differential speed of the cutter stacks pull and tease apart fibrous material whilst the leading edge and sides of the cutter teeth crop and shear plastic into small strips. The circumferential land of the cutter crushes friable or brittle material a unique combination in the field of waste processing.
CRUSH
SHEAR
CROP
Published information other than that marked certified is to be used as a guide only
3 16
Current
July 2007
X
MODEL
CT203P
FLANGE NB Inches
4
CT203Q
234
720
CT203R
360
804
CT205S
10
524
1150
CT205T
12
634
1549
Notes:
Maximum permissible loads are the same for both flanges The pipe work should always be supported independantly of the Muncher
Published information other than that marked certified is to be used as a guide only
3 17 Nov 2006
Basic Code Features Body Material Product Mark No. Throat Size Cast Iron Stainless Steel TR Muncher 1996 300mm (12") 500mm (20") Pipeline 100 N.B. to BS4504 Pipeline 150 N.B. to BS4504 Machine Type and Flange Bore (Metric Flanges Drilled to BS4504 PN16 and Imperial Flanges Drilled to ANSI B16.5 Class 150) Pipeline 200 N.B. to BS4504 Pipeline 250 N.B. to BS4504 Pipeline 300 N.B. to BS4504 Pipeline 4" N.B. ANSI Pipeline 6" N.B. ANSI Pipeline 8" N.B. ANSI Pipeline 10" N.B. ANSI Pipeline 12" N.B. ANSI Gear Unit c/w 1.5kW Motor Gear Unit c/w 2.2kW Motor Gear Unit c/w 4kW Motor Motor Gear Unit c/w 2HP Motor Gear Unit c/w 3HP Motor Gear Unit c/w 5HP Motor Cutter No. of Teeth Thickness 8.0mm (0.3150") Material (Cutters) Oblique Field Variation Typical Code C T 2 0 3 D * T 1 B 2 / Stainless Steel Chromium Molybdenum Steel B 1 2 / CAM 11 5.5mm (0.2165") D E F T 1 A 20" Throat 12" Throat 500mm Throat 300mm Throat Description 1 C S T 2 0 0 3 5 C D E F G P Q R S T A B C 2 3 4 5 6 7 8 9 10 11 12
Variation 13 14 15
V 1
A 2
R 3
Published information other than that marked certified is to be used as a guide only
3 18 Nov 2006
3.94 14.57 40.15 8.07 0.94 19.25 16.14 4.88 5.51 14.17 14.29 0.31 0.71 7.09 8.66 5.90 14.57 40.15 9.06 0.98 21.26 16.14 6.10 1.57 14.17 13.94 0.31 0.87 9.45 11.22 7.87 14.57 40.15 10.08 1.14 23.27 16.14 8.07 0.63 14.17 13.82 0.47 0.87 11.61 13.50 9.84 14.57 46.85 11.06 1.26 27.24 18.11 8.07 1.18 16.14 19.45 0.47 1.02 13.98 15.98 11.81 14.57 46.85 13.07 1.26 31.26 18.11 10.35 -0.67 16.14 18.58 0.47 1.02 16.14 19.01 3.94 15.55 44.49 8.07 0.94 19.25 16.14 4.88 6.65 14.17 14.29 0.31 0.71 7.09 8.66 5.90 15.55 46.06 9.06 0.98 21.26 16.14 6.10 3.82 14.17 13.94 0.31 0.87 9.45 11.22
2.95 - 5.36 7.87 15.55 46.06 10.08 1.14 23.27 16.14 8.07
9.84 15.55 51.57 11.06 1.26 27.24 18.11 8.07 3.43 16.14 19.45 0.47 1.02 13.98 15.98 11.81 15.55 51.57 13.07 1.26 31.26 18.11 10.35 1.57 16.14 18.58 0.47 1.02 16.14 19.01
Published information other than that marked certified is to be used as a guide only
3 19 Nov 2007
The sewage (or sludge) Grinder/Disintegrator shall be of the twin shaft, slow speed, high torque design. The main body inlet and outlet will be variable to accept standard flanged pipework from 4" up to 12" nominal bore. The shaft centers will not exceed 5, and the speed of rotation will not exceed 75rpm. Each shaft will be fitted with identical interleaving cutters and spacers of approximately 6 major diameter and having between 9 and 11 teeth. The tooth profile shall be saw pattern design. Each shaft shall be designed on a cantilever principle having twin ball bearings located in the main bearing housing. The ball bearings will be protected by mechanical seal cartridges. There will be no seals or bearings at the lower end of the cutter chamber. Shaft stack clamping screws will have opposite handed threads to prevent loosening during normal operation. The shaft stack module will be orientated at an angle between 20 and 30 degrees to the vertical enabling rejected material to be caught in a trash trap. Provision will be supplied for cleaning/flushing of the trash trap via ports. The shaft stack module will be capable of being withdrawn from the main body without disturbance to the installation. A 'Maintenance Period Screen' will be supplied to temporarily replace the module. Drive to the machine will be provided to one shaft by a helical/worm gearmotor. Drive will be divided between shafts using spur gears of case hardened steel. The machine is to be complete with a PLC based control system and provide the following functions: 1. To operate in normal on/off mode. 2. To provide sufficient overload protection. 3. To provide automatic jam clearance reversal action and resume to normal duty. 4. To activate automatic shutdown after three jams within 60 seconds. The logic must be able to differentiate between a locked rotor full overload requiring instant reversal and an allowable periodic low level overload allowing an ongoing running period before reversal mode is engaged.
ITEM SHAFTS CUTTERS & SPACERS CASING MECHANICAL SEALS DRIVE Descrip tion Shall be machined from 4140 alloy steel hexagonal stock, with a 55-59 HRC minimum surface hardness. Shall be of chromium/molybdenum alloy steel, hardened, tempered and ground. Cutters shall be hardened to 45-50 HRC and spacers to 41-46 HRC. Shall be of cast iron, stainless steel, or gunmetal dependent on application. Will have a maximum working pressure in excess of 30 PSI, having faces of solid tungsten carbide and be of a cartridge design with integral bearings and seals. Will be of the integral motor/gearbox speed reducer type close coupled to the main grinder module, by a coupling capable of transmitting full torque output of the gearbox under a stall condition. The machine will be finished with two pack acrylic.
PAINTWORK
Published information other than that marked certified is to be used as a guide only
4 1 Nov 2006
ORIENTATION In the TR Muncher unit the shaft seals are at the top only and the cutter stack is automatically pitched at 25 when installed normally on the integral feet of the main body. The trash trap is situated directly below the cutter banks to catch rejected unbreakable material. Therefore installation of the unit at any orientation other than normal i.e. horizontal, is not recommended.
Published information other than that marked certified is to be used as a guide only
4 2 Nov 2006
CLEAN OUT FACILITY Using the two clean out access ports, flanged hoses and valves can be fitted to give an automatic flushing sequence at sites where grit/solids are known to cause problems.
WATER IN
SOLIDS OUT
SOLENOID VALVES
Published information other than that marked certified is to be used as a guide only
4 3 Nov 2006
Sewage discharge is seldom constant and daily flow rates cannot be selected on the basis of total volume divided by 24 hours. To establish a viable throughput rate the total calculated volume for a 24 hour day should be averaged over a 16 hour period. The flow rate is usually identified in terms of total population or type of premises for which sewage facilities are required. The typical domestic water consumption figure is 48 gallons per person per day. The figures for types of premises are given overleaf. Calculation 1 No. of persons x 48 16 x 60 Calculation 2 In terms of population: Daily Flow Rate GPM In terms of premises: Daily Flow Rate GPM
Due to habits common to a civilized society peak flow conditions occur. It is this fact which when related to the particular requirements which determines product selection. The type of sewerage system to be used will have an effect on the peak flowrate for which a weighting factor may be used. This can be one of three types. System Type Combined system Separate system Partially separate system Factor 6 3 3
Maximum flow rate or peak flow can now be established by multiplying the result of the relevant calculation (1 or 2) by the appropriate System factor. Example Based on total population and combined system Maximum Flow Rate GPM
No. of persons x 48 x 6 16 x 60
Published information other than that marked certified is to be used as a guide only
4 4 Nov 2006
Gallons PER PERSON PER DAY 4-7 85-110 7 12 20 25-45 25 50 5 70-100 80 50 50-70 5 5-15 5 50-70 5 15-40 15 90-150 15-20 320 5-10 55 105 260-320 35-60 25 25-40
Example Material Handled Sludge (High Solids Content) Solids Content 6% Max. Flow 440gpm From Chart 1, locate 440gpm on the 6% DS curve. The indicated model is the CT203 (8) giving a pressure differential of 2.47 PSI.
Published information other than that marked certified is to be used as a guide only
STATUS
F lo w C h aracteristics fo r M o d el C T 203 T R M u n ch er
MODEL RANGE TR
7.00
Current
6.00
8% D S 6% D S 0% D S
4% D S
2% D S
5.00
4.00
P re s s u re D iff (P S I)
3.00
C T 203Q (6")
PERFORMANCE CURVES
2.00
2 HP HP 2 3HP 3HP 5 HP HP 5
C T 203P (4")
SECTION
PAGE
DATE
1.00
0.00 300 400 500 600 700 800 900 1000 1100 1200
100
200
Published information other than that marked certified is to be used as a guide only
C a p a c ity (U S G P M )
Nov 2007
STATUS
F lo w C h aracteristics fo r M o d el C T 205 T R Mu n ch er
MODEL RANGE TR
7.00
Current
8% D S 6% D S 2% D S 0% D S
4% D S
5.00
4.00
P ressu re D iff (P S I)
3.00
C T 205S (10")
PERFORMANCE CURVES
2 2 HP HP 3HP 3HP 5 5 HP HP
2.00
PAGE DATE
SECTION
1.00
0.00
Published information other than that marked certified is to be used as a guide only
500 1000 C ap acity (G P M ) 1500 2000 2500
Nov 2007