SCADAPack
Compact, versatile controller for telemetry and remote SCADA solutions
Ever-expanding SCADA systems, focused on gathering process data from geographically dispersed remote sites, are placing increased demands on engineering and maintenance personnel. In an environment of shrinking operational budgets and rising labour and material costs, finding the right controller that can do more for less is crucial.
With energy costs on the rise, alternate sources such as solarpower are being increasingly exploited wherever challenging power conditions exist. Controllers that consume less power and can easily interface with solar infrastructure are needed.
In recent years, government agencies have been instituting stringent environmental, security and safety regulations. As a result of several high-profile cyber-attacks and environmental disasters, public and governmental awareness is at its highest level. Noncompliance to the regulations can be dangerous for users and the environment, and very expensive if fines are levied.
03
04
SCADAPack Smart RTUs offer an array of exible connectivity and programming features that reduce design and implementation time:
Wide range of connectivity options: easily retrot into legacy systems, or expand current systems
Integrated Trio data radios: extend operational range without affecting control panel footprint
Built-in radio
Open SCADA
Modbus DNP3 IEC60870-5
Open communication protocols
Flexible programming options: easy-to-use, multi-language tools for all skill levels
05
Gas ow metering (O&G) or pump control (W&WW) combined with data logging, PLC control & RTU communication in one device
An integrated data-logger provides enhanced control and data logging capabilities that increase operational efciency and reduce cost
Smart RTU and sensor all in one package
Remote conguration and diagnostics features allow system deployment and maintenance tasks to be executed from a centralised location over existing communication infrastructure.
Low-power models achieve signicant cost savings due to the smaller solar panel/battery size required to power the unit
Centralised Server
ClearSCADA IEC 61131-3 E Configurator 3rd-party SCADA Host
> Ensure secure and reliable data from field to control room
SCADAPack Smart RTUs provide tools to ensure that remote communication links are not compromised by malicious intent or interference from other communication networks: Enhanced security suite: IEEE1711 (AGA12) encryption & IEC62351 (DNP3) authentication for maximum system security mitigates effects of interference with data monitoring and control commands
ClearSCADA Telepace Studio Firmware Loader IEC 61131-3 3rd-party SCADA Host SCADALog Realflo ProductionPlus
Time-stamped event logging provides audit trail of operational data changes and other key data reliability indicators
06
Realflo is compliant with API21.1 custody transfer and AGA3, AGA7, AGA8, NX 19 gas flow calculation standards.
07
Water/Wastewater Solutions
Optimised for remote pumping networks
SCADAPack E Smart RTUs offer all the features and benets of the SCADAPack with the added capabilities of DNP3 and IEC 60870-5. They have an embedded historian allowing time-stamped event logging and data sampling for extended periods of time. Distributed Network Protocol (DNP3) provides exible, secure communications between devices. Ensuring that there are never holes in the data even when communication links go down, DNP3 reduces the number of costly and time-consuming maintenance trips to the eld. With advanced features such as peer-to-peer communication, remote diagnostics, point object alarm handling, time proles and point quality reporting, SCADAPack E Smart RTUs are ideally suited for a wide range of demanding water and wastewater applications such as pumping station active overow mitigation, energy optimization and asset management. When used with ClearSCADA critical infrastructure remote management software, centralised SCADAPack E conguration and security management integration offers signicant savings in total cost of ownership for geographically distributed water and wastewater assets. IEEE1711 (AGA12) encryption protects DNP3 data transmission using unique security keys, ensuring data condentiality and integrity for revenue metering data and critical operations.
Water Treatment
Long-range Wireless
08
SCAD
Analog Inputs
On-board1 8: 0-20mA, 4-20mA 0-5V 0-10V n/a 8: 0-20mA, 4-20mA 0-5V 0-10V 5: 0-10V, 0-20mA 1: 0-32.7VDC 5: 0-10V, 0-20mA 1: 0-32.7VDC 8: 0-20mA, 4-20mA 0-10V 0-5V n/a 8: 0-20/ 4-20mA or 0-5/1-5V 8: 0-20mA/ 0-10V 1: 0-32.768V 8: 0-20/ 4-20mA 0-5/0-10V 3: 0-20/ 4-20mA 0-5/1-5 VDC 1: 0-32.7 VDC
Analog Outputs
On-board1 2: 0-20mA 4-20mA Optional n/a 2: 0-20mA 4-20mA Optional 2 or 4: 0-20mA 4-20mA Optional n/a 2: 0-20mA 4-20mA Optional n/a
Digital Inputs
On-board1 16: 12/24V 48V 115/125V 240V n/a 16: 12/24V 48V 115/125V 240V 8: Dry contact, Shared with output points. 8: Dry contact, shared with output points 32: (12/24V, 48V, 115/125V, 240V) 3: 24VAC/ 30VDC, shared with Counter inputs 1: 30V interrupt 3: 24VAC/ 30VDC, shared with Counter inputs 1: 30V interrupt 16: 12-24/120/ 220V-VAC 3: 24VAC/ 30VDC, shared with Counter inputs 1: 30V interrupt 32: dry contact Shared with outputs 3: 24VAC/ 30VDC Shared with Counter inputs, 1: 30V interrupt input 32: 12/24V, 48V, 115/125V, 240V 6: selectable as input or output
Digital Outputs
On-board1 10: dry contact or 10: solid-state n/a 10: dry contact or solid-state 8: open drain, Shared with input points. 8: open drain, Shared with input points. 16: dry contact 1: Controller Status Output 1: Controller Status Output 12: Dry contact 1: Controller Status Output 32: dry contact Shared with inputs 1: Controller Status Output 16: Dry contact 6: selectable as input or output
Frequency Inputs
On-board1 1: 0-10Hz or 0-5kHz (dry contact) 3: 0-5 kHz shared with digital inputs, 1: 0-500Hz, interrupt input 1: 0-6 kHz turbine or dry contact
General
Turbine Inputs Serial Ports 2: RS232/ RS485 1: Peripheral n/a 2: 0-10kHz (turbine or dry contact) 2: RS232/RS485 1: RS232 1: RS485, 1: RS232/RS485, 1: RS232 2: RS232 1: RS232/ RS485 n/a 3: RS232, 1: RS232/RS485 2: RS232 1: RS232/ RS485 1 1: RS232 1: RS232/ RS485
USB Ports Ethernet Ports EFM Flow Runs Programming Software Modbus DNP3
1
Master and Slave: Modbus RTU, Modbus ASCII, Modbus/TCP, Modbus UDP Level 2 Slave
Number of on-board I/O may be further expanded for any SCADAPack using Expansion I/O Modules. Refer to individual product data sheets for detailed specications.
09
DAPack
Water Applications SCADAPack 300E & SCADAPack ES
DNP3 Level 4 core database, Modbus layer, IEC 60870-5-101/103/104, optional DF1 support Programming: IEC61131-3, configuration: E Configurator DNP3 Secure Authentication & IEEE 1711 (AGA12) support
314E 330E 334E 350E 357E ES
Analog Inputs
On-board1 8: 0-20mA, 4-20mA 0-5V 0-10V n/a 8: 0-20mA, 4-20mA 0-5V 0-10V 5: 0-10V, 0-20mA 1: 0-32.7VDC 5: 0-10V, 0-20mA 1: 0-32.7VDC 8: 0-20mA, 4-20mA 0-10V 0-5V 6 or 12: 0-5V, 1-5V, 0-20mA, 4-20mA
Analog Outputs
On-board1 2: 0-20mA 4-20mA Optional n/a 2: 0-20mA 4-20mA Optional 2 or 4: 0-20mA 4-20mA Optional 2 or 4: 0-20mA, 4-20mA
Digital Inputs
On-board1 16: 12/24V 48V 115/125V 240V n/a 16: 12/24V 48V 115/125V 240V 8: Dry contact, Shared with output points. 8: Dry contact, shared with output points 32: (12/24V, 48V, 115/125V, 240V) 16 or 32: 10-30VDC
Digital Outputs
On-board1 10: dry contact or 10: solid-state n/a 10: dry contact or solid-state 8: open drain, Shared with input points. 8: open drain, Shared with input points. 16: dry contact 8 or 16: DPDT Relay, (NO/Common/NC)
Frequency Inputs
On-board1 1: 0-10Hz or 0-5kHz (dry contact) 0 - 40Hz 4: 0 - 1kHz Shared with digital inputs
General
Turbine Inputs Serial Ports 2: RS232/RS485 2: 0-10kHz (turbine or dry contact) 2: RS232/RS485 1: RS232 1: RS485, 1: RS232/RS485, 1: RS232 n/a 3: RS232 2: RS232/RS422/ RS485 n/a 2: 10/100BaseT
USB Ports Ethernet Ports EFM Flow Runs Programming Software Modbus DNP3 / IEC60870-5
1
1: Peripheral n/a
1: Peripheral 1: 10/100BaseT n/a IEC61131-3 Master and Slave: Modbus RTU, Modbus/TCP
DNP3 Level 4 Slave, Peer-to-Peer, Data Concentrator Master; IEC60870-5-101 (Slave), -104 (Server), -103 (Master)
Number of on-board I/O may be further expanded for any SCADAPack using Expansion I/O Modules.
11
FlowStation
Pump Controller
Pumps Supported Control Modes Pump Alternation SMS and E-mail Event Logs BlackBerry Interface Extensibility Web Server Alarms Level Control Level Transducer Signal Input Serial Ports Ethernet Communication Protocols GPRS Modem Web/LAN Security USB Memory Stick Commissioning Flush Valve Operation Setpoints Lift Station Maintenance Pump Performance Monitoring ClearSCADA Enhanced Integration Operating Environment 1, 2, or 3 (lead, lag, standby) Pump-down (Lift Station), pump-up (Reservoir) Automatic or xed Alarm reporting and acknowledgement (requires optional GPRS modem) Operator, Event Type, Time and Date of event BlackBerry Bold hand-held browser for viewing and alarm acknowledgement (GPRS modem required) I/O modules, user logic programming using TelePace Studio, custom web interface content Web interface for conguration, monitor, and control Logging and assignable alarm priorities Level sensor or oat switch-based 4-20mA, 0-20mA, 1-5V 3: for connection to SCADA Radios, local smart sensors and auxiliary devices such as motor protection relays or remote I/O 1: 10/100BaseT for web-browser access to local touch screen, laptop or Ethernet radio to corporate WAN SCADA-ready with Modbus and Modbus/TCP 1: optional User logon authentication, and friendly IP list FlowStation auto-conguration, event and alarm log recording I/O simulation and test modes Support for automatic or controller-based Pump Down/Up, congurable in 3 groups for operation during wet/dry season, or minimising of peak power consumption Fat-ring reduction and pump-down sludge removal algorithms to reduce frequency of wet well cleaning Pump start statistics, run time accumulations and history logs; pump current monitoring (optional) ClearSCADA host software provides pre-congured lift station templates for rapid rollout of new installations FlowStation 110 -40C to 70C (-40F to 158F) Touch Screen 0C to 45C (32F to 113F) GPRS Modem -30C to 70C (-22F to 158F) Hazardous Locations North America Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 per CSA Std C22.2 No. 213-M1987 / UL1604 UL listed and CSA certied to the following standards: CSA Std. C22.2 No. 213-M1987 - Hazardous Locations. CSA Std. C22.2 No. 142-M1987 - Process Control Equipment. UL Std. No. 1604 - Hazardous (Classied) Locations. UL Std. No. 508 - Industrial Control Equipment. Europe ATEX II 3G, Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2) Does not include Wireless versions. Australia IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2) Does not include Wireless versions. (pending)
Safety Certications
13
Features
Analog Inputs (AI) Analog Outputs (AO) Turbine Meter Counter Inputs (TI) Counter Inputs (CTRI) Digital Inputs (DI) Digital Outputs (DO)
Communications
Serial Port Serial Protocol Ethernet Port Ethernet Protocols
Functional
Gas Flow Calculations Gas Compressibility Calculations Event/Alarm History Logs
Density Calculations Measurement Update AGA 3, 7, V-Cone, Wafer Cone Calculation Update Alarm and Event Log Hourly History Daily History Gas Quality History Passwords Hardware Multivariable Transmitter
14
Flow Computer
AGA-3 1992/2000 orice plate and V-Cone AGA-8, 1992 (detailed) and NX-19 35 days hourly history, 35 days daily history, 700 events and 300 alarms API 21.1, BLM Onshore Order #5 and EUB Directive 17 Realo 6.40 and newer COM2 and COM3: Modbus RTU/ASCII Terminations for one: RTD input 1: Turbine Meter 1: selectable as sourcing or sinking, congurable Pulse Width Com 1: Direct to internal sensor or RS-485, 2-wire, half duplex to external sensor Com 2: For optional internal spread spectrum radio Com 3: Integrated Bluetooth wireless technology General : Radio modem compatible with Bluetooth wireless technology enabled products. Distance: Bluetooth Class 1. Up to 100m (330 ft.) (when communicating with another Class 1 device) Antenna: Integrated chip antenna
Features
Conguration Interface Protocols Temperature Measurement Counter Input Gas Sampler Output Communication Ports
Bluetooth Communication
Optional integrated Trio K-Series 900 MHz Spread Spectrum or FreeWave FGR09CSU 900MHz spread-Spectrum, or third-party radio connected to Com2 Solar Panel Power: 32W max. Shunt regulation, temperature compensated. Battery type: DIP switch-selectable for Cyclon Pure Lead, Gelled Electrolyte (Gel) or Absorbed Glass Mat (AGM) Backlit LCD, 2 lines X 20 characters, indication of ow data, charging states Non-contacting wake-up switch, power management Differential pressure ranges 200 to 840 inH2O 0.05% of Span for Spans 10% of URL Differential pressure range 30 inH2O 0.10% of Span for Spans 10% of URL Absolute pressure ranges 30 inH2O 0.05% of Span for Spans 10% of URL 13.5V nominal 108mW with Integrated sensor interface, gas ow calculations, display for 15 minutes per week and Bluetooth communications for 7.5 minutes per week 130mW with external sensor version, as above SolarPack 410 (not including the display and battery) 5% RH to 95% RH, non-condensing, 40oC to 55oC (40oF to 131oF) Display: 20oC to 55oC (4oF to 131oF)
Sensor Performance
Accuracy
Power
System Voltage Power Consumption
General
Environment
15
ProductionPlus
Gas Well Optimisation
Well Optimisation Gas well optimisation for the life of the well Operates in Manual Control, Intermitter, Advanced Intermitter and Plunger Control Scalable solution accommodates single wells or large multi-well pads up to 30 wells Accutech sensors for wellhead pressures, plunger arrival sensors, and liquid storage tank level Single or dual float, tank level monitoring with set point alarms including automatic pad shut-in SCADAPack 4203 is used for each well to provide well optimisation and custody transfer electronic flow measurement SCADAPack 4203 platform runs the ProductionPlus Smart RTU application and Realflo Flow Computer application SCADAPack 300 monitors all Accutech sensors and networks this data to 4203 well Smart RTU Provides communication gateway between the SCADA Host and network of well Smart RTU Modbus Operator Interface offers local control and detailed plunger arrival log Trio serial or Ethernet data radio connects well pad to SCADA Host ClearSCADA SCADA Host template mimics the ProductionPlus control interface Datalogging at each well controller is retrieved by the Host for trending and plunger arrival history
Wireless Sensors Tank Level Monitoring Well Smart RTU Pad Smart RTU
Schneider Electric
Telemetry & Remote SCADA Solutions 48 Steacie Drive, Kanata, Ontario K2K 2A9 Canada Direct Worldwide: 1 (613) 591-1943 Fax: 1 (613) 591-1022 Toll Free within North America: 1 (888) 267-2232 www.controlmicrosystems.com Document Number M01012-19
September 2011
tk