Vous êtes sur la page 1sur 69

SRAN 7.

0 HARDWARE
PRESENTATION
SRAN WIRELESS TRAINING
1 SRAN WIRELESS TRAINING
Introduction
L obj ect i f de cet t e f ormat i on est de donner un aperu sur l es
caract ri st i ques des produi t s wi rel ess SRA7. 0.

La prsent e Format i on s i nscri t dans l e cadre des prparat i f s pour l e
prochai n proj et du dpl oi ement du SRAN7. 0 au prof i t de l oprat eur
I AM .

L obj ect i f Pri nci pal est de se f ami l i ari ser avec l e mat ri el , connat re
ses caract ri st i ques t echni ques et mat ri ser l a procdure correct e de
l i nst al l at i on .
2 SRAN WIRELESS TRAINING
TABLE DE MATIERE
Challenge of network expansion
2
Challenge of network expansion Procdure Dinstallation
3 SRAN WIRELESS TRAINING
1
Produits SRAN7.0
2
Description Hardware
3
Prsentation des Boards
4
Procdure dinstallation
Produits SRAN7.0
Pour Le SRAN7. 0 , La sri e 3900 des MBTS sera Ut i l i se .

Cet t e sri e , avec l a BBU3900 peut support er l e GSM, UMTS,
ou LTE en si ngl e mode .

En dual mode l a BBU3900 , support e l es modes GU , GL et
UL .
En cas d ut i l i sat i on de 2 BBU3900s , l es 3 modes Peuvent t re
support s.
Page4
Produits Srie 3900
Page5
Page6
BTS3900
Item Description
Dimension (mm) 600 (W) * 450 (D) * 900 (H)
Poids vide 57Kg
Poids en full Configuration 132Kg

La BTS3900 se prsent e comme un Cabi net ayant l es
caract ri sques sui vant es :
Page7
On y t rouve:

BBU3900
MRFU, GRFU, LRFU
I ndoor macro cabi net


CONFIGURATION



BTS3900L


La BTS3900L se prsent e comme un Cabi net ayant l es
caract ri sques sui vant es :
Environnement dinstallation Indoor
Dimension 600x 450 mm x 1,600 mm

Poids Empty: 100 kg
Fully configuration: 232 kg

8 SRAN WIRELESS TRAINING


CONFIGURATION


1-RFU: Radio Frequency Unit
2-FAN Assembly Unit
4-DC Distribution Unit
5-BaseBand Unit
6-Cable through
7-Remaining space
9 SRAN WIRELESS TRAINING
BTS3900AL
Page 10
BTS3900AL est compos dun cabinet de 9RFU AC , dun cabinet 9RFU DC ,
et dun cabinet pour les batteries .

BTS3900AL_AC cabinet BTS3900AL_DC cabinet
DBS3900
Page11
L obj ect i f de cet t e part i e est de bi en mai t ri ser l es cart es et l es port s exi st ant s sur
chaque boards.

Une bonne mai t ri se de ces port s permet une i nt ervent i on rapi de en cas d al arms cl ean up
ou en cas de rsol ut i on de probl mes .
Dans cet t e part i e , nous al l ons se f ocal i ser sur l es boards sui vant s :


Description Hardware
Boards Partie

RFU/RRU

Partie Radio
BBU Control et transmission en
bande de base
DCDU Power system
FAN Environnement
12 SRAN WIRELESS TRAINING
Partie Radio
La part i e Radi o est prsent e par l es boards RFU/ RRU


Les boards RRU and RFU permet t re l e si gnal en bande de base l a f rquence modul e
Les boards WBBP( en BBU) permet t re de t ransmet t re l e si gnal modul e l a f rquence
de base

Outdoor part: RRU on the tower
13 SRAN WIRELESS TRAINING
RFU :Radio frequency Unit:
I l en exi st e pl usi eurs t ype :

Ces cart es se ressembl ent en t erme des port s exi st ant s , mai s di f f rent en t ermes de
caract ri st i ques support es.
Cartes Nom Systme support
GRFU GSM RFU GO
DRFU Double RFU GO
WRFU WCDMA RFU UO
MRFU Multi-Mode RFU GO,UO,LO,GU,GL
LRFU LTE RFU LO
14 SRAN WIRELESS TRAINING
MRFU : Multi Mode Radio Frequency Unit
Port Etiquette Remarques
RF port(DIN
CONNECTOR)
ANT_T
X/RXA

Connexion avec les
antennes
RF port(DIN
CONNECTOR)

ANT/
RXB


Connexion avec les
antennes

CPRI port CPRI0 Connexion avec la
BBU
Power Port PWR Connexion avec la
DCDU

15 SRAN WIRELESS TRAINING
WRFU : WCDMA RADI O Frequency Unit

WRFU Dsi gne WCDMA Radi o Frequency Uni t .

La WRFU est di st i ngue par sa pui ssance et
sa capaci t de Processi ng.
40 W WRFU support e 2 carri ers.
80 W WRFU support e 4 carri ers.

GRFU GSM RADI O Frequency Unit
GRFU Dsi gne GSM radi o f requency uni t .

La GRFU support e si x carri ers.
RRU :Radio Remote Unit
Utilis pour les sites Outdoors.

Il convertit et transfrent les signaux entre la BBU et lantenne.

On y trouve les memes ports que la RFU.
Outdoor part: RRU on the tower
18 SRAN WIRELESS TRAINING
RRU &RFU
Les deux bords doivent tre vrifis dans les cas suivants :

VSWR: En vrifiant les RF Ports sils sont bien connects.
En Cas RTWP : Vrifier la puissance mise des boards .
En cas des Cross :

Cross Feeder : Vrifier et suivre les feeders .
Cross Fiber : Vrifier les fibre entre les RRU&RFU et la WBBP.
19 SRAN WIRELESS TRAINING
BBU3900 : BaseBand Unit
On y t rouve :
Boards Name
WBBP WCDMA BaseBand Processing Unit

WMPT WCDMA Main Processing Transmission
Unit
GTMU GSM Transmission and Timing
Management
UMPT Universal Main Processing and
transmission
UTRP Universal transmssion Processing unit
UPEU Universal Power and Environment Unit
UEIU Universal Environment Interface Unit
20 SRAN WIRELESS TRAINING
La BBU3900 est divise en slot comme suit :


BBU3900 :Rpartition des Cartes
Chaque slot est dsign pour un type ou plusieurs types de cartes.

21 SRAN WIRELESS TRAINING
Configuration des Boards
Numrotation des Slots :



Slot 16
Slot 18
Slot 19
Page22
GTMU :GSM Transmission & Timing & Management Unit
WMPT :WCDMA Main Processing and Transmission unit
WBBP :WCDMA Baseband Process Unit
UPEU :Universal Power and Environment Interface Unit
UEIU :Universal Environment Interface Unit
UTRP :Universal Transmission Processing unit
La BBU3900 est dfinie de faon unique par un seul identifiant ESN.

LESN (Electronic Serial Number )est utilis lors de la mise en service et
lintgration de la BTS.

Lors de linstallation , chaque quipe doit enregistrer et fournir cet identifiant
au quipes BSS.

Si la MBTS supporte 2G/3G , lquipe dinstallation doit collecter et
enregistrer le numro de srie de la WMPT.



BBU3900 :ESN (Electronic serial Number)
23 SRAN WIRELESS TRAINING

La GTMU se prsente comme suit :


GTMU:GSM Transmission and Timing Monitoring Unit


Permet de connecter la BTS avec les modules Radio RFU/RRU.
Permet de connecter la BTS avec Lquipement de Transmission .
Permet de le commissioning de La BTS (la mise en service).
Permet La synchronisation de La BTS.


24 SRAN WIRELESS TRAINING

On y trouve :



Port Remarques
CPRI1 CPRI5 Utils pour se connecter au
RFU/RRU
Port Ethernet Se connecter localement la BTS
Port FE Transmission IP
Port Optique Transmission IP sur support optique
USB Permet de mettre le logiciel
directement la BTS
E1/T1 Transmission TDM /Synchronisation
25 SRAN WIRELESS TRAINING
GTMU:GSM Transmission and Timing Monitoring Unit

La GTMU se prsente comme suit :




Lors de la transmission sur IP , le Port E1 permet de founir la synchronisation
(Lhorloge ) pour la BTS.

Pour se connecter localement la BTS , il faut configurer l@ IP suivante 17.21.2.16

26 SRAN WIRELESS TRAINING
GTMU:GSM Transmission and Timing Monitoring Unit

La WMPT se prsente comme suit :


WMPT : WCDMA Main Transmission Processing Unit


Permet de connecter la NodeB avec les modules Radio RFU/RRU.
Permet de connecter la BTS avec Lquipement de Transmission .
Permet de le commissioning de La BTS (la mise en service).
Permet La synchronisation de La BTS.


27 SRAN WIRELESS TRAINING

On y trouve :



Port Remarques
Port Ethernet

Port Ethernet

Port FE

Transmission Sur FE (10Mbits
1000Mbits)

Port Optique

Transmission FE optique

USB

Permet de mettre le logiciel
directement la BTS

E1/T1

Permet deTransmission TDM
/Synchronisation

28 SRAN WIRELESS TRAINING
WMPT : WCDMA Main Transmission Processing Unit
Page29
UMPT : Universal main processing & transmission Unit
UMPT (Universal Main Processing & Transmission unit) est un module de synchronisation ,
de transmission qui permet le controle des ressources au sein de la BBU3900.
LUMPT est Utilis pour lUMTS et LTE.
Module rserv SRAN7.0

La WBBP se prsente comme suit :


WBBP:WCDMA BaseBand Processing Unit


30 SRAN WIRELESS TRAINING
Il en existe plusieurs types qui diffrent en termes de cellules supportes et
de capacit CE :




31 SRAN WIRELESS TRAINING
WBBP:WCDMA BaseBand Processing Unit
Il en existe plusieurs types qui diffrent en termes de cellules supportes et de
capacit CE :




32 SRAN WIRELESS TRAINING
WBBP:WCDMA BaseBand Processing Unit
La WBBP permet de connecter la BBU3900 au RFU&RRU travers les cables
CPRI.


WBBP:WCDMA BaseBand Processing Unit




33 SRAN WIRELESS TRAINING
La WBBP permet de connecter la BBU3900 au RFU&RRU travers les cables
CPRI.

Il Permet de transfrer les signaux RF aux autres cartes travers le Backup
plan.

Chaque Port CPRI est configur de tel sorte quil supporte soit U900 ou
U2100.

En cas de Cross : Il est prfrable de vrifier et de suivre les modules CPRI
entre la WBBP et les Modules Radio.

La BBU3900 peut supporter jusqu 6 module WBBP par site , soit une
capacit maximale de 1536CE en (UL et en DL).

WBBP:WCDMA BaseBand Processing Unit




34 SRAN WIRELESS TRAINING

LUTRP est un module dextension qui supporte diffrents types de
transmission selon le type :


UTRP :Universal Transmssion Processing Unit


35 SRAN WIRELESS TRAINING
LUTRP2 et lUTRP9 Permet La Transmission FE/GE sur support lectrique et
optique:

LUTRP ne peut tre install que dans les slots 0 et 4 de la BBU3900.
36 SRAN WIRELESS TRAINING
UTRP :Universal Transmssion Processing Unit
La Carte FAN se prsente comme suit :
Il occupe le slot 16 de la BBU.
Il permet le control de la vitesse du ventilateur et reporte ltat de la
temprature la WMPT.

UBFA Universal BBU Fan Unit Type A :
37 SRAN WIRELESS TRAINING
Il permet de fournir des modules CPRI excdentaires en cas de besoin.
Gnralement , il est utilis en cas de sites 4 secteurs tri-
mode(GSM900,GSM1800 et UMTS).

LUBRI ne peut tre install que dans le slot 2 de la BBU3900.
UBRI: Universal BaseBand Radio Interface Board

38 SRAN WIRELESS TRAINING
Environment Board :

Pour le control et le report des alarmes , la BBU3900 utilise deux cartes:

UPEU : Universal Power monitoring Unit .
UEIU: Universal Environment Interface Unit.


LUPEU occupe le slot 19 de La BBU et LUEIU occupe le slot 18 .

Environment Board :






Lutilisation de ces cartes dpend essentiellement du nombre dalarmes
configurer.
Numbers of alarms Monitoring boards
1 to 8 UPEU
1 to 16. UPEU + UEIU
UPEU :Universal Power Environment Unit




Il permet de convertir le voltage -48V ou -24V +12V.
Il se prsente comme suit :

UEIU :Universal Environment Interface Unit




Il permet de de transfrer les signaux dalarmes provenat des alarmes
extrieures la WMPT.

Il se prsente comme suit :

Exemple de configuration dalarme :



Chaque pair de pin du cable RJ45 supporte une alarme extrieure.
Exemple de configuration dalarme :



Cue pair de pin du cable RJ45 supporte une alarme extrieure.
EXT ALM 0
1
Orange/White
AC Power
Orange
2
Green/White
Door Open Green
3
Blue/white
Flood
Blue
4
Brown/White
Smoke
Brown
EXT ALM 1
5
Orange/White
Air Condition Control Fail
Orange
6
Green/White
A/C1 Failure
Green
7
Blue/white
A/C2 Failure
Blue
8
Brown/White
High Temperature Brown
DCDU :Direct Current Distribution Unit



Le PS Power systme est prsent par la Carte DCDU .

Cette carte se prsente comme suit :



On y trouve les ports suivants :
Port Etiquette Description
Power Input NEG(-)
RTN(+)
Power Output Load0 , Load1.. Alimenter chaque
module de la BTS
Power Switch SW0,SW1 Interrupteur.
DCDU :Direct Current Distribution Unit
Ports on the DCDU-12C panel

Functions
The DCDU-12C fournit 10 -48 V DC outputs en utilisant des fusibles qui
permettent de satisfaire les exigneces en terme power distribution.
DCDU 12C

Functions
The DCDU-11A performs the following functions:
Supports one -48 V DC input of 160 A or two -48 V DC inputs of 80 A.
Provides ten -48 V DC outputs of a maximum of 25 A.
Supplies power to all components in the cabinet.
DCDU -11A
FMU : FAN Monitoring unit :



Cette carte permet de rgler la temprature et reporter les alarmes de la BBU

Numrotation des CPRI Ports
Numbering of WBBP CPRI ports: The WBBPb and WBBPd are not differentiated.
The WBBPs in Slot3 on the BBU are numbered from left to right with the start
number of U-CPRI0. The WBBPs in Slot2 are numbered from left to right with the
start number of U-CPRI3.
Numbering of GSM CPRI ports: The GTMUs are consistent with ports numbered
from G-CPRI0 to G-CPRI5. The UBRIs are consistent with ports numbered from G-
CPRI6 to G-CPRI11.


Page50
RF Configuration
The typical configuration when only one
module is used in a single sector.
Page51
RF Configuration (Cont.)
The typical configuration when two modules
are used in a single sector.
Page52
Scenario 1: Single-Band Site with No More
Than Three Sectors
In this scenario, no more than three sectors are configured at GSM and UMTS
sites. The slot and sector allocation principles are described as follows:
Sector No. M1 M2 M3
Slot Slot0Slot1 Slot2Slot3 Slot4Slot5
Mapping Between Slots and CPRI Ports
Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 None U-CPRI1 None U-CPRI2 None
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Page53
Scenario 1: Single-Band Site with No More
Than Three Sectors
The typical configurations of GSM 900M S4/4/4+UMTS 900M S1/1/1
(1M+1M+1M)
(WBBPb) GSM 900M S4/4/4+UMTS 900M S1/1/1
(1M+1M+1M)
(WBBPd) GSM 900M S4/4/4+UMTS 900M S1/1/1
(1M+1M+1M)
Page54
Scenario 2: Single-Band Site with More Than
Three Sectors
In this scenario, the GSM or UMTS is configured with more than three
sectors. The slots dont have fixed allocation with the sectors;
Mapping Between Slots and CPRI Ports

Slot Slot0 Slot1 Slot2 Slot3 Slot4 Slot5
WBBPb CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
WBBPd CPRI U-CPRI0 U-CPRI1 U-CPRI2 U-CPRI3 U-CPRI4 U-CPRI5
GTMU CPRI G-CPRI0 G-CPRI1 G-CPRI2 G-CPRI3 G-CPRI4 G-CPRI5
Page55
Scenario 2: Single-Band Site with More Than
Three Sectors
The typical configurations of GSM 900M S4/4/4/4/4/4+UMTS 900M
S1/1/1/1/1/1 (1M+1M+1M+1M+1M+1M)
(WBBPb) GSM 900M S4/4/4/4/4/4+UMTS 900M
S1/1/1/1/1/1 (1M+1M+1M+1M+1M+1M)
(WBBPd) GSM 900M S4/4/4/4/4/4+UMTS 900M
S1/1/1/1/1/1 (1M+1M+1M+1M+1M+1M)
Page56
Scenario 3: Dual-Band Site with No More Than
Three Sectors
The typical configurations of GSM 900M S4/4/4 & GSM 1800M S4/4/4+UMTS 900M
S1/1/1 & UMTS 1800M S1/1/1 (1M+1M+1M+1M+1M+1M)
(WBBPb) GSM 900M S4/4/4 & GSM 1800M S4/4/4+UMTS 900M
S1/1/1 & UMTS 1800M S1/1/1 (1M+1M+1M+1M+1M+1M)
(WBBPd) GSM 900M S4/4/4 & GSM 1800M S4/4/4+UMTS 900M
S1/1/1 & UMTS 1800M S1/1/1 (1M+1M+1M+1M+1M+1M)
Page57
Procdure dinstallation

58 SRAN WIRELESS TRAINING
expansion bolt (x4)
1. Determine the installation position of the cabinet and install expansion bolt assemblies.
Installing the Cabinet on the Concrete Floor
2. Secure the cabinet.
Cabinet
bottom
M12x60 bolt (x4)
Spring washer 12
Flat washer 12
Insulating washer
16
90
52 mm to 60 mm
M12x60 bolt

Spring washer

Flat washer

Expansion tube

Do not use a hammer drill to
drill holes on the concrete pad
through the holes on the base.
3. Adjust the cabinet level and measure the resistance between the base and the bolts.
The resistance between the base and the four expansion bolt
assemblies should be respectively measured.
Level
Adjusting bolt
Anchor hole
Concrete floor
Marking template
Meeting the resistance
requirement: > 5 M
Concrete
plinth
Concrete
plinth
59 SRAN WIRELESS TRAINING
Installing the Base on the Concrete Floor
Anchor hole
Marking template
2. Secure the base.
1. Determine the anchor holes, drill holes, and install expansion bolt assemblies.
3. Adjust the base level and measure the resistance between the base and the bolts.
Insulating spacer
(x2)
Level
Adjust M12x30 bolts (x4)
on site.
The resistance between the base and the four expansion bolt
assemblies should be respectively measured.
When installing a BTS3900L on a base,
use a marking template matching the
base to determine the positions of the
holes for installing the cabinet.
For details, see step1 on page 2.
Do not use a hammer drill to drill holes on the
concrete pad through the holes on the base.
Meeting the resistance
requirement: > 5 M
M12x60 bolt (x4)
Spring washer 12
Flat washer 12
Insulating washer
Concrete floor
60 SRAN WIRELESS TRAINING
Installing the Base on the ESD Floor
1. Determine the installation position of the base and drill holes on the ESD floor. 1. Determine the installation position of the base and drill holes on the ESD floor.
Concrete floor
2. Temporarily fasten the ESD floor and supports.
1. Determine the installation position of the base and drill holes on the ESD floor.
Support for the ESD
floor
ESD floor
For details on how to drill holes and install
expansion bolt assemblies on the concrete floor
as shown in the figures and , see page 2.
When tightening the height locking bolts, you
should tighten the bolts in the middle before
tightening the bolts on both sides.
3. Install the base on the ESD floor.
M12x60 bolt
Insulating spacer (x2)
4. Adjust the base level and measure the resistance between the base and the bolts.
(For details, see step 3 on page 3.)
Height locking bolt (both
sides)
Mounting holes for the
support
Height locking bolt (middle)
Anchor hole
Marking template
ESD floor
M12x70 bolt
Spring washer 12
Flat washer 12
M12x60 bolt (x4)
Spring washer 12
Flat washer 12
Insulating washer
When installing a BTS3900L on a base,
use a marking template matching the
base to determine the positions of the
holes for installing the cabinet.
For details, see step1 on page 2.
Do not use a hammer drill to drill holes on the
concrete pad through the holes on the base.
61 SRAN WIRELESS TRAINING
Installing the Cabinet
Installing the Cabinet and PGND Cable
Installing the BBU
M12x50 bolt (x2)
DCDU-11A
RFU
BBU
DCDU-11A
RFU
BBU
Fan box
Fan box
The cabinet door can be removed before the cabinet is installed for
easy operations. Remove the cabinet door before installing the
cabinet, and do not re-install the door until the power-on check is
completed.
62 SRAN WIRELESS TRAINING
Installing the PGND Cable
Installing the Cabinet and PGND Cable
External ground bar
Installing Cables
In this document, the cable color and equipment appearance is for reference only. The actual cables and equipment may differ from what are shown in the figures.
Attach labels before routing cables.
When cutting the BTS3900 input power cable, reserve an extra length of 300 mm. Add an OT terminal to the cable on site.
Installing the Input Power Cable
PWR
LOAD7
PWR
LOAD8
63 SRAN WIRELESS TRAINING
Installing Transmission Cables
E1 cable or FE cable can be configured according to the transmission mode of the base station. Only
one transmission mode is supported by the base station working in the GSM standard, and two
transmission modes can be supported by the base station working in the UMTS standard. For
details about the configurations and cable connections, For details about the configurations and
cable connections, see the BTS3900 (Ver.C) Hardware Description.
Installing the Input Power Cable
When arranging for the power cable on site, do not expose the metal wire.
Plastic cover plate
DCDU-11A
RFU
BBU
RFU
Fan box
Fan box
RFU
BBU
Fan box
BBU
DCDU-11A
DCDU-11A
NEG(-)
RTN(+)
64 SRAN WIRELESS TRAINING
Installing Transmission Cables
Installing the E1 Cable
a
Ensure that both ends of the E1 cable are disconnected. Then, weld connectors to the bare wires
at one end of the E1 cable all at once.
Installing the FE Cable
b
E1/T1 E1/T1
E1/T1
E1 transmission in the GSM modes E1 transmission in the UMTS modes
E1 transmission in the LTE modes
FE0
FE/GE0
FE1
SFP1
FE transmission in the UMTS modes
(over the electrical port)
FE transmission in the UMTS modes
(over the optical port)
FE transmission in the LTE modes
(over the optical port)
FE transmission in the LTE modes
(over the electrical port)
SFP0
E1 transmission in triple modes
E1/T1
FE0
FE transmission in the GSM modes
65 SRAN WIRELESS TRAINING
P1
Installing the FE Cable
b
FE transmission in triple modes
(over an electrical port)
FE transmission in triple modes
(over an optical port)
FE/GE0
FE/GE1
Power-On Check
The normal status of the indicators on the
GTMU/WMPT/LMPT/UMPT:
RUN indicatorBlinking
ALM indicatorOFF
ACT indiactorON
The normal status of the indicators on the
WBBP/LBBP:
RUN indicatorBlinking
ALM indicatorOFF
The normal status of the indicators on the FAN:
STATE indicatorBlinking green
The normal status of the indicators on the UPEU:
RUN indicatorON
The normal status of the indicators on the UCIU:
RUN indicatorBlinking
ALM indicatorOFF
ACT indicatorON
Mx or Sx indicatorSteady green
The normal voltage range of the DC output power
to the DCDU-11Ais from:
-38.4 V DC to -57 V DC
The normal status of the indicators on the RFU:
RUN indicator: Blinking
ALM indicator: OFF
ACT indicator: ON
VSWR indicator: OFF
CPRI indicator: Steady green
The normal status of the LEDs on the Fan box is as
follows:
RUN indicatorBlinking
ALM indicatorOFF
Ensure that the external power supply is normal before power on, and that all the MCBs in the
cabinet are set to OFF.
The cabinets must be powered on in seven days after being unpacked, and the period of the power-
off state of the cabinet cannot exceed 48 hours during maintenance.
After the power-on check is complete, close the
cover of the case, and the cabinet door.
67 SRAN WIRELESS TRAINING
Appendix
Removing the CPRI Cables
Product 4 Product 5
Product 3 Product 2 Product 1
Push Push Push

Push
Push
Pull
Pull
Pull
Pull
Pull
Waterproofing Outdoor Cables
1. Wrap three layers of waterproof tapes.
2. Wrap three layers of insulating tapes.
Extend the tape.
Cable tie
Waterproof tape
Insulating tape
The waterproof tape should be wrapped for
an extra length of 20 mm away from the
connectors at both ends.
The tapes should be wrapped around the
connector from the lower part to the upper
part. When wrapped for another layer, the
tapes may not be cut.
When wrapping the waterproof tape, ensure
that the upper layer of the tape covers at least
50% of the lower layer.
The insulating tape should be wrapped for
an extra length of 20 mm away from the
waterproof tapes at both ends.
68 SRAN WIRELESS TRAINING
Pin Assignment
X1 Wire Color Wire Type Label
1 Blue
Twisted pair RX1
2 White
3 Orange
Twisted pair RX2
4 White
5 Green
Twisted pair RX3
6 White
7 Brown
Twisted pair RX4
8 White
19 Gray
Twisted pair TX1
20 White
21 Blue
Twisted pair TX2
22 Red
23 Orange
Twisted pair TX3
24 Red
25 Green
Twisted pair TX4
26 Red
X1 Wire Type Coaxial SN Label
1 Tip
1 RX1
2 Ring
3 Tip
3 RX2
4 Ring
5 Tip
5 RX3
6 Ring
7 Tip
7 RX4
8 Ring
19 Tip
2 TX1
20 Ring
21 Tip
4 TX2
22 Ring
23 Tip
6 TX3
24 Ring
25 Tip
8 TX4
26 Ring
1. Pin assignments for the wires of the 75-ohm E1 coaxial
cable
2. Pin assignments for the wires of the 120-ohm E1 twisted
pair cable
Green/white
Brown/white
Gray/white
Blue/red
Orange/red
Green/red
Orange/white
Blue/white
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base Bantian Longgang Shenzhen 518129
Peoples Republic of China
www.huawei.com
69 SRAN WIRELESS TRAINING