0 Calculations
Section
Credit
Category
Equati
Sustainable Sites on prep: Teeceeetee
SS2 Impervious %
% Impervious Area calculation = Total Impervious Area ( m2)
Total Site Area ( m2)
1 .D Heat Island Reduction/Non Roof SS3 Shade of Impervious areas Shade % Shaded Impervious Area ( m2)
= Total Impervious Area ( m2)
1 .E Heat Island Reduction/ Roof Total roof area≤ (area of SRI roof x 1.33) + ( area of vegetated roof x 2)]
1 G/H Water Efficient Irrigation SS4 Landscape Coefficient Klandscape = KSpecies x KDensity x Kmicroclimate
SS6 Total Potable Water Applied (L) TPWA (L) = Area (m2) X ETL (mm)
IE (Irrigation Efficiency)
SS10 Rainwater Volume Collected Rainwater Volume ( L) = Collection area (m2) X Collection Efficiency ( %) X Average Rainfall (mm)
1I Innovative WasteWater Technology SS7 Sewage Volume Sewage Volume Generate (L) = Uses X Duration (mins or flushes) X Water Volume ( L)
Use ( mins or flushe)
(Male Occup X Male Sewage Volume Generated) L (Female Occup X Female Sewage Volume
SS8 Daily Sewage Generation Daily Sewage Generation ( L/day) = + Generated) L
SS9 Annual Sewage Generation Annual Sewage Generation (L) = Daily sewage Genration ( L/day) X Workdays
1J Water Use Reduction 20% or 30% Daily Water Use Daily Water Use ( L/day) = (Male Occup X Male Water Use )L + (Female Occup X Female Water USe) L
Total Annual Water Use Volume Annual Water Use (L) = Daily Water use ( L/day) X Workdays - Grey/Storm Water Reuse
=
1 .K OnSite Renewable Energy SS11 Renewable Energy % Renewable Energy = REC/ DEC
2 Development Density
SS12 Development Density Development Density ( m2/ heactare) = Building are ( m2) / Property Area ( Hectare)
SS13 Density Radius ( m) Density Radius ( m) = 3x √(propety area ( hectares) x 10 000 m2/hectare)
3 .2 Alternate Transportation SS14 Full Time Employee FTE = Worker Hours ( hrs) /8
SS16 Showering Facilities for Bucycle user Showering Facilities = Bicycle Spaces / 8
Wec 1 Water Reduction Use Daily Water Use Daily Water Use ( L/day) = (Male Occup X Male Water Use )L + (Female Occup X Female Water USe) L
Total Annual Water Use Volume Annual Water Use (L) = Daily Water use ( L/day) X Workdays - Grey/Storm Water Reuse
1.3 .3 EA6 %Annual HVAC ECR Baseline Reduction (ECBHVAC - DEC HVAC)
= (EBC hvac) x (Project Area / Total Segment Area)
Optimize Energy Performance -HVAC
EA6 %Annual HVAC ECR Alternative Reduction (A- EBC HVAC - DEC HVAC)
Baseline
= (A- EBC hvac)
∑Total Power in Project ( No of total ∑Energy star Power ( total energy star items x
1.4 .4 Equipment and Appliances Item and its Rated Power Number items in Project Number of Energy Star Items
items x rated power) rated power)
% Energy Star Rated Power = ∑Energy star Power ( total energy star items x rated power)
∑Total Power in Project ( No of total items x rated power)
4 Green Power
Eqc 8 .1&.2 Daylight EQ1 Daylight Factor = Window Window area (m2) X Atcutal T vis)
Window Height Factor X Geometry X Floor Area (m2) Min T vis
10% or 20% (EP 30%)of Net Construction Material Cost = Total Material Cost- MEP -Mr 3.1, 3.2, 3.3 + Div 12
MRc 4 .1&.2 Recycled Content
MRc 5 .1&.2 Regional Material 20% (40%) or 10% (20%)of Net Construction Material Cost = Total Material Cost- MEP + Div 12
MRc 6 Rapidly Renewable Materials 5% (EP 10%) of Total Construction Material Cost = Total Material Cost- MEP -Mr 3.1, 3.2,+ Div 12
MRc 7 Certified Wood 50% (95%) of Total wood Cost = Total Wood Cost - MEP -Wood Mr 3.1, 3.2, 3.3 - Mr 4.1 post-consumer wood