Sub-DS0 multi plexer

provi di ng voi ce, data,


Ethernet, and other
uni que servi ces
( teleprotecti on,
omni bus)





M ultiple n x 64 kbps, E1/T1 or fractional E1/T1 main links, with combined TDM
capacity of up to 8 M bps ( 124 timeslots)
10/100-M bps IP access link for transparent circuit extension over IP, employing
RAD s TDM oIP technology
Self-healing TDM E1/T1 rings and Resilient Fast Ethernet Ring ( RFER) technology
( under 50 msec switchover protection)
Wide range of I/O modules for ISDN, voice, low-speed, high-speed,
teleprotection, Ethernet, ISDN and more






M egaplex-2100/2104
M odular Integrated Access M ulti plexers

Data Sheet
Where to buy >

See the product page >
M P-2100/2104 is a modular integrated
access TDM multiplexer, which integrates
multiple dedicated data, voice, ISDN and
LAN channels over multiple main
( network) links. M P-2100/2104 equipped
with 8-port main link modules in
conjunction with 12-port high-speed
modules provides a traffic payload
capacity of up to 248 DS0 timeslots.
The flexible, modular M P-2100/2104 with
a wide choice of I/O ( user interface)
modules was designed for applications
ranging from small campus networks to
multi-site corporate networks or extensive
carrier access solutions.
The equipment conforms to international
standards, ensuring compatibi lity in
multi-vendor environments worldwide.
MARKET SEGMENTS
M egaplex-2100/2104 can be used in the
following applications:
M egaplex provides multiservice access
for utility and transportation
companies, to reduce the number of
units needed to collect all the traffic,
low speed, high speed, teleprotection,
voice, teleconference and more ( see
Figure 1 and Figure 2)
M egaplex can be used to keep the
huge installed base by maintai ning
legacy and special services whi le
enabling carrier network migration to
NGN/PSN. It can be deployed at the
carrier s point-of-presence, in the
exchange, or at an organization s
central office, as well as remote sites,
( see Figure 3 for carrier extension over
copper lines) .
M egaplex enables carriers to successfully
deploy bundled services, ISDN services and
Internet access. The integration of a broad
range of services makes M egaplex a
cost-effective access device, with reduced
deployment and maintenance costs.
M egaplex with TDM oIP technology
provides a cost-effective, versatile and
modular solution for transmitti ng legacy
TDM traffic over IP networks. This is
especially suitable for large corporations,
utilities or power companies that are
seeking a future-proof migrati on path to
IP networks.
INTEROPERABILITY
M egaplex-2100/2104 is interoperable with
M egaplex-4100, ASM i, IPM UX, DXC and
FCD devices, and can interwork with
third-party devices or networks complying
with PDH and Ethernet standards.



Megaplex-2100/2104
M odular Integrated Access M ulti plexers
Applications
POP
Data Info
Central Station
Station #1
Line #n
Fiber/
Copper
Display
Board
Station #2
Fiber/
Copper
Station #n
Station #1 Station #2
Fiber/
Copper
Station #n
Line #1
Fiber/
Copper
Ticketing
Signaling
Megaplex
Line #n
Line #1
Megaplex Megaplex Megaplex
Ticketing
Megaplex Megaplex Megaplex
Train
Station
Train
Station

Figure 1. O mnibus Teleconference Voice Application for Railway Connectivity
SDH/SONET
E1/T1
VHF Control Site
4W/E&M
RS-232
E&M
HS-RN
VHF Radio Site
4W/E&M
RS-232
E&M
HS-RN
RS-232 RS-232
HS-RN HS-RN
Megaplex Megaplex
Control
Switch
Control
Room
Radar Monitor Radar
VHF Radio

Figure 2. Air Traffic Control using VC-4/E& M /PO S M odules
Aggregation Site
STM-1
Megaplex-2100
Aggregation Site
n x E1
SDH/SONET/
PSN
PBX
ISDN-NT
AnalogLB
AnalogPOTS
(2W/4W)
Router
IP VPN
Backup
ISDN
(U)
4W
E&M
FXS/FXO
2W
LB
Megaplex-4100
PBX
ISDN-NT
AnalogLB
AnalogPOTS
(2W/4W)
Router
IP VPN
Backup
ISDN
(U)
4W
E&M
FXS/FXO
2W
LB

Figure 3. Carrier Network M igration


Data Sheet
Specifications
Compliance
E1: ITU-T Rec. G. 704 and G. 706, G. 736
T1: AT& T TR-62411, ANSI T1. 403-1989
ITU-T Rec. G. 703, G. 704, and G. 733
Ethernet : IEEE 802. 3, 802. 1p, 802. 1Q ,
802. 3U
MANAGEMENT
Control Port
Interface: RS-232 sync DCE port
Data Rate: 0. 3, 1. 2, 2. 4, 4. 8, 9. 6, 19. 2,
38. 4, and 57. 6 kbps
Connector: 9-pin D-type female
Ethernet Management Port
Type: 10BaseT
Connector: 8-pin RJ-45
Management Options
M enu-driven interface with
password-protected access, authorization
levels, Telnet, RADview-EM S, SNM Pv2:
O ut-of-band
Inband, via the TDM main link ports
using frame overhead or over a
dedicated timeslot
DIAGNOSTICS
Tests
Local main link loopback
Local main link loop towards remote unit
Local and remote BERT on channels, ports,
bundles, individual timeslots and
individual bits in a timeslot
Local and remote loopbacks on channels,
ports, and timeslots
Forward and remote tone injection in
individual timeslots ( voice channels
only)
IP connectivity check ( ping)
Alarms
Time and date stamped
Last 256 alarms stored in RAM on CL
module, readable by management
system or terminal
Current alarms status
Statistics
AT& T statistics when using ESF framing
for T1 trunks, or CRC-4 multiframing
for E1 trunks
Performance statistics for bundles and
LAN ports
GENERAL
Environment
O perating temperature: -10C to 55C
( 14F to 131F)
Storage temperature: -20C to +70C
( -4F to +158F)
Humidity: up to 95% , non-condensing
Note: Actual operating temperature range is
determined by the speci fic modules i nstalled i n the
chassis, and might require special ordering options.
For extended operating temperature ranges,
contact your local RAD Busi ness Partner.
Physical
MP-2100 (4U-high)
2 power supply module slots
2 CL module slots
12 slots for I/O and M L modules
Height: 18 cm ( 7 in) ( 4U)
Width: 44 cm ( 17 in)
Depth: 33 cm ( 13 in)
Weight ( fully loaded) : less than 17 kg
( 37 lb)
MP-2104 (2U-high)
Built-in power supply ( optional built-in
voice ringer or ISDN power feeder is
available)
1 CL module slot
5 slots for I/O and M L modules
Height: 9 cm ( 3. 5 in) ( 2U)
Width: 44 cm ( 17 in)
Depth: 33 cm ( 13 in)
Weight ( fully loaded) : less than 6 kg
( 13 lb)




7
6
4
-
1
0
0
-
1
1
/
1
2

(
1
2
.
9
)

S
p
e
c
i
f
i
c
a
t
i
o
n
s

a
r
e

s
u
b
j
e
c
t

t
o

c
h
a
n
g
e

w
i
t
h
o
u
t

p
r
i
o
r

n
o
t
i
c
e
.


2
0
0
8

2
0
1
2

R
A
D

D
a
t
a

C
o
m
m
u
n
i
c
a
t
i
o
n
s

L
t
d
.

T
h
e

R
A
D

n
a
m
e
,

l
o
g
o
,

l
o
g
o
t
y
p
e
,

a
n
d

t
h
e

t
e
r
m
s

E
t
h
e
r
A
c
c
e
s
s
,

T
D
M
o
I
P

a
n
d

T
D
M
o
I
P

D
r
i
v
e
n
,

a
n
d

t
h
e

p
r
o
d
u
c
t

n
a
m
e
s

O
p
t
i
m
u
x

a
n
d

I
P
m
u
x
,

a
r
e

r
e
g
i
s
t
e
r
e
d

t
r
a
d
e
m
a
r
k
s

o
f

R
A
D

D
a
t
a

C
o
m
m
u
n
i
c
a
t
i
o
n
s

L
t
d
.

A
l
l

o
t
h
e
r

t
r
a
d
e
m
a
r
k
s

a
r
e

t
h
e

p
r
o
p
e
r
t
y

o
f

t
h
e
i
r

r
e
s
p
e
c
t
i
v
e

h
o
l
d
e
r
s
.

International Headquarters
24 Raoul Wallenberg Street
Tel Aviv 69719, Israel
Tel. 972-3-6458181
Fax 972-3-6498250, 6474436
E-mail market@rad.com
North America Headquarters
900 Corporate Drive
Mahwah, NJ 07430, USA
Tel. 201-5291100
Toll free 1-800-4447234
Fax 201-5295777
E-mail market@radusa.com
www.rad.com O rder this publication by Catalog No. 803987



Megaplex-2100/2104
M odular Integrated Access M ulti plexers
Data Sheet
Power
Power Supply Input
110/115 VAC ( 85 to 150 VAC) , 50/60 Hz
220/230 VAC ( 150 to 264 VAC) , 50/60 Hz
-48 VDC ( -36 to -57 VDC)
-24 VDC ( -18 to -40 VDC)
24 VDC with floating ground ( 18 to
40 VDC)
MP-2100 (without Ringer)
M aximum O utput Power:
AC: 250W
DC: 250W
M aximum Input Power:
AC: 250W
DC: 315W
Note: M aximum power consumption for a system
with redundant power supplies is 250W.
MP-2104
M aximum O utput Power
AC: 120W
DC: 120W
AC w/Ringer: 300W
DC w/Ringer: 290W
M aximum Input Power:
AC: 160W
DC: 160W
AC w/Ringer: 300W
DC w/Ringer: 350W
Ordering
Basic unit i ncludes a chassis, single common logic
module, si ngle power supply and power supply
cables. M ai n link and I/O modules are ordered
separately ( see separate module data sheets for
details and ordering informati on) .
RECOMMENDED CONFIGURATIONS
M P-2100/115/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, 115 VAC, 10BaseT
management port
M P-2100/115/R/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, 115 VAC,
redundant power supply and common
logic, 10BaseT management port
M P-2100/230/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, 230 VAC, 10BaseT
management port
M P-2100/230/R/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, 230 VAC,
redundant power supply and common
logic, 10BaseT management port
M P-2100/48/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, -48 VDC, 10BaseT
management port
M P-2100/48/R/2UTP
M odular integrated access multiplexer, 4U
chassis with 12 module slots and CL. 2
common logic module, -48 VDC, redundant
power supply and common logic, 10BaseT
management port
M P-2100M -CL. 2/UTP
Common Logic 2 for M P-2100, 10BaseT
UTP Ethernet management port
M P-2104/115/2UTP
M odular integrated access multiplexer, 2U
chassis with 5 module slots and CL. 2
common logic module, 115 VAC, 10BaseT
management port
M P-2104/230/2UTP
M odular integrated access multiplexer, 2U
chassis with 5 module slots and CL. 2
common logic module, 230 VAC, 10BaseT
management port
M P-2104/48/2UTP
M odular integrated access multiplexer, 2U
chassis with 5 module slots and CL. 2
common logic module, -48 VDC, 10BaseT
management port

Vous aimerez peut-être aussi