Being responsible is our foundation

Thinking ahead makes it possible


Innovation is the essence

GRUNDFOS WASTEWATER

Business with an attitude


Knowledge The sharing of knowledge, experience
and expertise across our global network will always
lead our business forward.
Innovation Combining the best technology with
fresh ways of thinking, we will continue to develop
even better pumps, systems, services and standards.
Solution With a complete product range, capable
of providing every conceivable water solution, we are

96 51 24 34 08 03

the most complete player on the market.

www.grundfos.com

Heavy-duty submersible
sewage pumps 15 - 155 kW

Grundfos

Installation options

Submerged installation on auto-coupling, types 1 and 2

Large, powerful pumps for


handling unscreened raw sewage
Grundfos offers a full range of extremely dependable, powerful sewage pumps, designed for handling unscreened raw sewage. Our more than
forty years experience in providing specialised
pumps and pumping equipment for all kinds of
wastewater and sewage has taught us what our
customers demand from a sewage pump:

Submerged installation on auto-coupling system requires a base plate with a 90


bend, fixed to the bottom of the pit. When lowered into the pit along the guide
rails, the pump automatically connects to the base plate. The flexible neoprene
SmartSeal ensures a leak-proof connection between the pump and the auto-coupling.
Type 1:
To prevent sedimentation of sludge in connection with intermittent operation, we
recommend a stop level corresponding to the top of the pump housing. For sufficient
cooling in connection with continuous operation, the liquid level must always be
above the middle of the motor.

Powerful advantages

> Higher pump efficiency over time

Type 2:
Motor cooling is independent of the pumped liquid level, thanks to separate motor
cooling.

State-of-the-art technology makes the Grundfos


pumps extremely efficient and highly dependable. Innovative features such as the unique
SmartTrim adjustment of impeller clearance
provide low Cost of Ownership.

Vertical dry installation, type 3


The Grundfos sewage pumps can be installed either vertically or horizontally to
suit specific application arrangements. All pumps are 100% watertight, allowing
for dry installation with the workspace around the pump remaining clean and dry.
The pumps are fully flood-proof if an unexpected flooding should occur.

> Less downtime


The excellent solids handling capability of our
channel-impeller pumps guarantees maximum
operating time and substantial reductions in
maintenance costs caused by pump jamming
or clogging.

Motor cooling takes place by means of a cooling jacket.

> Lifelong reliability


Submerged installation, portable, types 4 and 5

The sturdy sewage pumps are designed for


continuous pumping under the most difficult
operating conditions. The well-proven design
is based on our long experience in the wastewater business.

Certain applications, such as construction sites, require portable submersibles. Where a


portable submersible is required, hoses of varying lengths and materials can be supplied.
Type 4:
To prevent sedimentation of sludge in connection with intermittent operation, we
recommend a stop level corresponding to the top of the pump housing. For sufficient
cooling in connection with continuous operation, the liquid level must always be
above the middle of the motor.

At Grundfos we maintain a close dialogue with


our customers to constantly improve pump
design and performance. Only this way can we
build the long-lasting partnerships on which
our business is founded.

Type 5:
Motor cooling is independent of the pumped liquid level, thanks to separate
motor cooling.

Horizontal dry installation, type 6


Horizontal dry installation improves the overall efficiency of the system as unnecessary components and bends are avoided. The feasibility of horizontal dry installation
depends on the floor space available as the system takes up slightly more space
than a vertically installed pump.
Motor cooling takes place by means of a cooling jacket.

>

>

Tough and reliable pumps...

- with many unique features

The Grundfos submersible sewage pumps are designed to reduce energy


consumption and to keep downtime costs at a minimum. Maintaining peak
efficiency throughout the entire lifetime of the system is a key issue:

Watertight encapsulated motor,


o
insulation class F (155 C), enclosure
class IP 68, with three thermal
sensors in the stator windings.

Watertight cable entry of


corrosion-resistant polyamide, or cast iron with soft
shapes to prevent damage
to the power cable.

Lower bearings comprise a single


or a double bearing

In horizontal or vertical
dry installations, some of
the pumps can be equipped
with a cooling jacket.

Seal condition monitoring (from frame size


50). A monitoring probe in the oil housing
gives early warning of seal leakage (optional).

Moisture detector
continuously monitors
the motor enclosure, and
automatically cuts off the
power in the event
of leakage.

Dynamically balanced
pump shaft of stainless
steel or fully protected
against contact with
pumped liquid. Conical
shaft end for safe
securing of impeller.

The Grundfos SmartSeal


gasket system provides
a completely leak-proof
connection.

SmartTrim system
allows easy adjustment
of factory-set impeller
clearance, maintaining
maximum pump efficiency.

Double mechanical shaft seal system


in intermediate oil chamber for reliable
sealing between the pumped liquid
and the motor. Primary seal with
SiC/SiC rings, and SiC/carbon rings
in the secondary seal.

Details

>

Advanced sealing technology

Operating conditions

In dry applications or in submerged installations at low water level efficient


cooling of the motor is essential. This is
achieved either through a cooling jacket
encasing the stator housing or by means
of built-in heat conduits transporting the
heat away from the motor.
Stator housing conduits
Cooling of the motor takes place by transferring
excess heat via the stator housing to the pumped
liquid. Applicable for Grundfos pump ranges
34, 42 and 46.

Cooling jacket

47 metres of backflow with no non-return valves


In the Pihlajanmki pumping station in Finland, water is being lifted 47 metres. The Grundfos pumps in this
installation have no non-return valves. Consequently, when the pumps are stopped, the entire water column
flows back to the pit through the pumps. With this arrangement the liquid in the pit is stirred up and mixed
to prevent sedimentation problems.

Some of the pumped liquid is led into the cooling jacket via a clearance behind the impeller.
An integrated screening system prevents solids
from entering the cooling jacket. By circulating
the liquid around the motor, excess heat is transferred to the pumped liquid and led away.
Applicable for Grundfos pump ranges
50, 54, 58, 62, 66 and 70.

Operating conditions and


maximum starting frequency
Pump application is restricted by the following
limits:

Maximum ambient temperature and


pumped liquid temperature: +40C
Storage temperature range: -30C to +60C
Maximum submergence: 20 m
Voltage tolerance: -10% to +10%
Pump starting frequency should not exceed the
recommendations indicated below. For shorter
periods of time a starting frequency of up to
double the recommended is permissible.

Range

Starts per hour

34, 42
46, 50, 54
58, 62, 66, 70

25
20
15

Explosion-proof versions
Automatic flushing of wet pits
The shaft seals of Grundfos pumps are capable of
rotating in either direction. When pumps are installed
with separate pipework, sludge sedimentation can
be effectively avoided by back flushing the system
at regular intervals.

For applications involving the risk of explosion,


or where otherwise required, explosion-proof
versions of the s-pumps are available.

Horizontally installed pumps with cooling jacket

Extended pump life


Trouble-free shaft seal operation is ensured by
springs located inside the oil chamber. The springs
are completely isolated from the pumped liquid.
Automatic removal of air and grit from the seal
area, in combination with silicon carbide primary
seal faces is the best guarantee for trouble-free
operation and extended pump life.

Reduced dry pit installation costs


In pumping stations with separate pipework for
each pump, costly non-return valves can be avoided.
Vertically installed pumps, with stator housing
conduit cooling.

Shaft seal

>

Motor

>

Grundfos SuperVortex impellers

Efficient impeller design

A unique impeller design

Large free passage for superior


solids handling

The unique design of the Grundfos SuperVortex


impellers provides high pumping efficiency and
less downtime. With a flow range from 4 l/s, the
Grundfos SuperVortex-impeller pumps are the
optimum solution for all small pumping stations.

Compromising on the ability to handle solids in


order to obtain higher pumping efficiency substantially increases the risk of clogging. More
clogging means more downtime and increased
operating costs.
The Grundfos channel-impeller pumps are capable
of handling solids up to 145 mm. The full free
passage, however, is much larger. The result is
less clogging and less downtime.

No clogging or jamming
In a SuperVortex-impeller pump, the flow is entirely outside the impeller. The design of the impeller ensures that long fibres, rags, etc. pass freely
through the pumps without getting caught and
without causing clogging or jamming. This means
less downtime and, consequently, reduced service
costs and higher pumping efficiency.

Semi-axial long-vane
impeller design

The design of the SuperVortex-impeller pumps


also prevents the common problem of jamming
between wear rings. A Grundfos SuperVorteximpeller pump needs no wear rings!

The length of an impeller vane is a key factor in


determining the length of fibres that can pass
through a pump without getting caught. The
Grundfos channel-impellers are of semi-axial
design with extra long vanes. This provides maximum performance and eliminates problems with
fibres or rags getting caught in the impeller.

Full performance curve without


operating limitations and vibrations
Due to the special power characteristics of the
Grundfos SuperVortex-impeller pumps, it is possible
to run the pumps right up to the maximum flow
on the curves without any risk of overloading the
motor. The steep performance curve means
minimal flow fluctuation with varying heads.

Non-clogging impeller vane design


Conventional double-channel impellers are
susceptible to clogging, as fibrous material tends
to enter both channels and get caught on the
leading edge. But thanks to the recessed leading
edge design of the Grundfos double-channel
impeller, the problem of clogging is virtually
eliminated.

Conventional vortex impeller


In pumps fitted with a conventional vortex impeller,
turbulent disturbance is liable to form around the
impeller. This will disrupt the flow pattern and result
in lower pumping efficiency and reduced head.

Tested under real conditions, this special doublechannel impeller design combined with a free
passage of minimum 100 mm enable the Grundfos
double-channel impellers to handle unscreened
sewage in heavy-duty applications. Maximum
efficiency is 80-85%.

Grundfos SuperVortex impeller


The liquid passes freely outside the impeller
without any turbulent disturbance.

SuperVortex

>

Channel impellers

>

Performance overview and type key

SuperVortex-impeller pumps

Performance overview Grundfos range of submersible sewage pumps

Low and high head - ranges 34, 42, 46 and 50

H
[m]

H
[m]

60 Hz

80

SV

48

60 Hz
ISO 9906 Annex A

60
5

44

40

40

30

36

12

32
20

28

11

24
10
2

20

12
4

10
8

16

3
2

0
5

10

20

30

40

50

100

200

300

400 500

1000

Q [l/s]
20

Area

10

40

60

80 100

200

Description

SuperVortex impeller, low and high head,


ranges 34, 42, 46 and 50

Channel impeller, medium head,


ranges 42, 46, 50, 54, 58 and 62

Channel impeller, low head,


ranges 54, 58 and 62

Channel impeller, medium head,


ranges 66 and 70

Channel impeller, high head,


ranges 46, 50, 54, 58 and 62

Channel impeller, high head,


ranges 66 and 70

400

600 800 1000

2000

3000

12

16

20

24

28

32

36

40 Q [l/s]

1500

20

40

60

80

100

140 Q [m/h]

120

Q [m/h]

Type key

Electrical and technical data

Example S1X244A H1
S 1
X 24 4
A H
Type range
GRUNDFOS submersible
wastewater pumps
Type of impeller
V
= SuperVortex
1
= Single-channel
2
= Two-channel
3
= Three-channel
Version
Blank =Non-explosion-proof,
X
=Explosion-proof
Rated motor power PN in kW
Number of poles
Pump generation
Head classification
E = Extra low head L =Low head M = Medium
head H = High head S = Super-high head
Type of installation
1 =Submerged installation on auto-coupling
2 =Submerged installation on auto-coupling
Motor cooling is independent of pumped liquid level
3 =Vertical dry installation with base stand
4 =Submerged installation, portable
5 =Submerged installation, portable. Motor
cooling is independent of pumped liquid level.
6 =Horizontal dry installation w. base stand and bracket

Technical data

Pump curve
No.

Pump type

1
2
3
4
5
6
7
8
9
10
11
12

SV 014 BL
SV 014 B
SV 024 B
SV 034 B
SV 034 CH
SV 044 CH
SV 052 C
SV 054 CH
SV 074 B*
SV 084 B*
SV 092 BH*
SV 122 BH*

Submerged installation

Pump Max. solids


range size [mm]
34
34
34
34
42
42
42
42
46
46
50
50

80
80
80
80
80
80
80
80
100
100
80
80

Outlet
[mm]

Weight
[kg]

80
80
80
80
80
100
80
100
100
80
80

60
60
60
60
100
100
100
135
125
170
170

Dry installation
Inlet Outlet Weight
DN
DN
[kg]

Hose
[mm]

Weight
[kg]

100
100
100
100
100
-

80
80
80
80
80
100
80
100
100
100
100

63
63
63
63
100
100
100
135
125
170
170

100
100
100
80
80
-

75
75
75
110
100
-

Motor 380 V
[380/660 V*]

Submerged
installation, portable
PN
[kW]

nN
[min-1]

IN
[A]

2.2
1715
5.8
2.2
1715
5.8
2.2
1715
5.8
3.0
1680
7.5
3.6
1725
10.0
4.6(3.6) 1730(1690) 11.9(10)
5.2
3460
12
4.6
1710
11.9
6.5
1750
16
8
1725
18.4
10.4
3535
23.1
12.5
3515
27

IS/IN
4.7
4.7
4.7
3.7
6.0
5(6)
7.7
5
5.8
5
9.8
8.4

() Motor data in brackets apply to installations 2, 3, 5 and 6.


*These data concern the 380/660 V types.

>

11

Performance

>

Channel-impeller pumps

Medium head
- ranges 42, 46, 50, 54, 58 and 62
H
[m]

H
[m]

S1

52

Low head - ranges 54, 58 and 62

High head
- ranges 46, 50, 54, 58 and 62
65

60 Hz

H
[m]

S1

11

40

35

20

35
9

24

30
8

20

19

16

18

14

17

25

10

10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [l/s]


50

12

100 150

200 250 300 350 400 450 500 Q [m/h]

10

20

50

30
100

40
150

50

60
200

70
250

80

90 100 110

300

Q [l/s]

400 Q [m/h]

350

Pump curve
No.

Pump type

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

S1 034 C
S1 044 C
S1 054 C
S1 074 AM*
S1 084 AM*
S1 094 BM*
S1 134 BM*
S1 164 M*
S1 204 M*
S1 314 AM*
S1 424 M*
S1 074 AH*
S1 084 AH*
S1 094 AH*
S1 114 AH*
S1 134 AH*
S1 164 H*
S1 204 H*
S1 244 H*
S1 314 H*
S1 424 H*
S1 524 H*

Submerged installation

Pump Max. solids


range size [mm]
42
42
42
46
46
50
50
54
54
58
62
46
46
50
50
50
54
54
58
58
62
62

100
100
100
100
100
100
100
100
100
100
100
80
80
80
80
80
80
80
80
80
80
80

17

9
8

12

11

10
1

5
0

0
0 20 40 60 80 100 120 140 160 180 200220 240260280300 Q [l/s]

100 200 300 400 500 600 700 800 900 1000 Q [m/h]

100

200

500

300
1000

400

500

1500

600

2000

700
2500

800

900 Q [l/s]

3000 Q [m/h]

Electrical and technical data

Electrical and technical data


Outlet
[mm]

Weight
[kg]

100
100
100
100
100
100
100
130
130
125
125
100
100
100
100
100
100
100
125
125
125
125

110
110
110
135
130
180/190**
190/210**
250/270**
250/300**
450,500/540**
600/650**
140
130
160/200**
160/200**
200/235**
250/285**
280/315**
400/430**
400/430**
580/615**
570/610**

Dry installation
Inlet Outlet Weight
DN DN
[kg]

Hose
[mm]

100
100
150
150
150
150
200
200
100
100
100
150
150
150
150
150
150

100
100
100
100
100
100
100
130
130
125
125
100
100
100
100
100
100
100
125
125
125
125

100
100
100
100
125
125
125
125
100
100
100
100
100
125
125
125
125

Motor 380 V
[380/660 V]*

Submerged
installation, portable

135
135
190
190
270/320***
300/320***
460
650/635***
200/210***
200
235
285
315
470
460/490***
670/635***
650/635***

Weight
[kg]
110
110
110
135
130
190
190
250/270****
250/300****
430/460****
600/650****
140
130
160/200****
160/200****
200/235****
250/285****
280/315****
435
420/430****
640/670****
600/610****

PN
[kW]

nN
[min-1]

IN
[A]

Pump curve
IS/IN

4.6(3.6) 1690(1715) 11.5(9.6) 5(6)


4.6(3.6) 1690(1715) 11.5(9.6) 5(6)
4.6
1690
11.9
5
6.5
1750
16
5.8
8
1725
18.4
5
10
1765
22.4
6.9
13.5
1745
22.7
7.5
15.5(17.5) 1745(1735) 39(41.2) 4.9(4.6)
20(22.5) 1745(1735) 41.2(47.3) 5.8(5)
31(32)
1750
63.2(64.3) 5.4(5.3)
40(42) 1775(1775) 88.4(92.2) 7.6
6.5
1750
16
5.8
8
1730
18.4
5
10
1765
22.4
6.9
11
1760
23.6
7.5
13.5
1745
27.7
7.5
15.5(17.5)
1740
39(41.2) 4.9(4.6)
20(22.5) 1745(1735) 43.7(47.3) 5.8(5)
25( 28) 1760(1750) 50.6(56.3) 6.8(6.1)
31
1735
64.5
5.3
40(42) 1770(1775) 82.3(92.2) 5.9(7.6)
48(52) 1765(1760) 1025(110.2) 6.4(6.2)

No.

Pump type

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

S1 164 AL
S1 204 AL
S1 314 L
S2 314 AL
S2 424 AL
S2 524 AL
S2 328 M
S2 408 M
S2 578 M
S2 578 H
S3 578 L
S3 808 L
S3 808 M
S2 808 H
S2 1106 M
S2 1106 H
S3 1406 L
S3 1406 M
S2 1406 H

Submerged installation

Pump Max. solids


range size [mm]
54
54
58
58
62
62
66
66
66
66
70
70
70
70
70
70
70
70
70

100
100
115
100
100
100
145
145
145
120
115
115
120
120
145
120
115
120
120

* These data concern the 380/660 V types.

*** installation type 3/installation type 6

*** installation type 4/installation type 5

** installation type 1/installation type 2

**** installation type 4/installation type 5

>

Weight
[kg]

200
200
200
200
200
200
300
300
300
250
500
500
300
250
300
250
500
300
250

355/370*
355/390*
490/550*
470/510*
655/650*
615/655*
810/915*
810/915*
950
950
1300
1500/1590*
1370/1520*
1200
1240/1270*
1240/1270*
1700/1830*
1390/1520*
1300/1320*

Inlet Outlet Weight


DN DN
[kg]

Hose
[mm]

Weight
[kg]

200
200
250
250
250
250
-

200
200
200
200
200
200
-

355/370***
355/390***
490/550***
470/510***
600/650***
615/655***
-

200 370/390**
200
390
200
550
200
510
200
650
200 655/695**
-

Motor
380/660 V

Submerged
installation, portable
PN
[kW]

nN
[min-1]

IN
[A]

IS/IN

15.5(17.5) 1750(1740) 39(41.2) 4.9(4.6)


20(22.5) 1745(1735) 41.2(47.3) 5.8(5)
31(32)
1735
63.3(64.5) 5.4(5.3)
31(32)
1735
63.3(64.5) 5.4(5.3)
40(42) 1775(1775) 94.4(92.2) 7.6
48(52) 1765(1760) 102.5(110.5) 6.4(6.2)
32
875
72.6
6.5
41
875
90.2
5.4
57
875
118.6
5.6
57
875
118.6
5.6
57
875
118.6
5.6
80
880
155.8
6.7
80
880
155.8
6.7
80
880
155.8
6.7
110
1180
213.1
7.3
110
1180
213.1
7.3
140
1185
276
8.7
140
1185
276
8.7
140
1185
276
8.7

* installation type 1/installation type 2


** installation type 3/installation type 6

Performance

Outlet
[mm]

Dry installation

() Motor data in brackets apply to installations 2, 3, 5 and 6.

() Motor data in brackets apply to installations 2, 3, 5 and 6.

12

13

15

15

10

0
0

14

20

13 14

4
2

15

15

25

16

20

18
4

10

16

16

30

12

12

18

40

28

19

20

45

32

40

21

10

36

45

22

50

60 Hz
ISO 9906 Annex A

ISO 9906 Annex A

24

22

55

50

60 Hz

26

60

S2, S3

S1, S2

ISO 9906 Annex A

48
44

H
[m]

28

60 Hz

ISO 9906 Annex A

Medium head - ranges 66 and 70

13

Performance

>

Dimensions and installation

Channel-impeller pumps

Submerged installation on auto-coupling (types 1 and 2)

High head - ranges 66 and 70


H
[m]
80

S1, S2
60 Hz

75

ISO 9906 Annex A

70
65

60
55

50

45

3
2

40
1

35
30
25
20
15
10
5
0

0 20 40 60 80100120140160180200220240260280300320340360 Q [l/s]
0 100 200 300 400 500 600 700 800 900 1000 11001200 Q [m/h]

Electrical and technical data


Pump curve
No.

Pump type

1
2
3
4
5
6

S2 704 AM
S1 704 H
S2 1004 AM
S2 1004 H
S2 1204 AM
S2 1204 H

Submerged installation

Pump Max. solids


range size [mm]
66
66
70
70
70
70

100
100
100
90
100
90

Inlet Outlet Weight


DN
DN
[kg]

Outlet
[mm]

Weight
[kg]

200
200
200
200
200
200

900/990*
800/830*
1100/1210*
1100/1200*
1100/1210*
1030/1320*

() Motor data in brackets apply to installations 2, 3, 5 and 6.

Dry installation

SuperVortex-impeller pumps

Motor
380/660 V

Submerged
installation, portable
Hose
[mm]

Weight
[kg]

PN
[kW]

nN
[min-1]

IN
[A]

IS/IN

73
95
95
120
120

1775
1780
1780
1770
1770

146.5
178.1
178.1
221.5
221.5

6.9
7.5
7.5
7.5
7.5

Pump range/
type
34
SV 014 BL
SV 014 B
SV 024 B
SV 034 B
42
SV 034 CH
SV 044 CH
SV 052 C
SV 054 CH
46
SV 074 B
SV 084 B
50
SV 092 BH
SV 122 BH

* Installation type 1/installation type 2

Material specifications
Part
Stator housing
Pump housing
Impeller
Pump shaft, pump ranges 34 to 62
Pump shaft, pump ranges 66 and 70*
Bolts and nuts
Cooling jacket, pump ranges 50 to 62
Cooling jacket, pump ranges 66 and 70
O-rings
O-rings, mechanical shaft seal
Bearings
Primary shaft seal
Secondary shaft seal
Lifting bracket, pump ranges 34 to 46
Lifting bracket, pump ranges 50 to 54
Lifting bracket, pump range 58
Cables
Cable entry
Surface protection
Oil

Material
Cast iron
Cast iron
Impeller cast iron/ductile iron
Stainless steel
Steel
Stainless steel
Ductile iron
Hot dip galvanized steel
NBR
FKM
Heavy-duty prelubricated ball or roller bearings
SiC/SiC
SiC/carbon
Cast stainless steel
Ductile iron
Galvanized steel
EPDM
PA/cast iron
150 my two-component epoxy coating
SAE 10 W 30

DIN/EN
EN-JL1040
EN-JL1040
EN-JL1040/EN-JS1050
1.4460
1.7225
1.4436
EN-JS1050
Rst 37-2

1.4408
EN-JS1050
Rst 37-2

AISI

329
316
80-55-06

Dimensions [mm]
DN

P R

80/100
80/100
80/100
80/100

640
640
640
640

555
555
555
555

85
85
85
85

455
455
455
455

270
270
270
270

130
130
130
130

150
150
150
150

130
130
130
130

99
99
99
99

160
160
160
160

184
184
184
184

206
206
206
206

60
60
60
60

180
180
180
180

220
220
220
220

18
18
18
18

20
20
20
20

123
123
123
123

167
167
167
167

65
65
65
65

80
80
80
80

48
48
48
48

80/100
80/100
100/80
80/100

695
695
795
695

615 80 475
615 80 475
615 180 520
615 80 475

270
270
310
270

155
155
150
155

155
155
150
155

155 99 160
155 99 160
150 120 260
155 99 160

184
184
180
184

206
206
220
206

60
60
60
60

180
180
180
180

220
220
220
220

18
18
18
18

20
20
20
20

123
123
205
123

167 65 80
167 65 80
180 121 180
167 65 80

48
48
48
48

100/80 775 645 130 560 330 170 175 220 120 260 180 220
100/80 775 645 130 560 330 170 175 220 120 260 180 220

60
60

180 220
180 220

18
18

20
20

205 180 121 180


205 180 121 180

48
48

100/80 965 805 100 705 465 180 180 190 120 260 180 220
100/80 965 805 100 705 465 180 180 190 120 260 180 220

60
60

180 220
180 220

18
18

20 205 180 121 180


20 205 180 121 180

48
48

Sizes DN 80/100 or DN 100/80 means that it is possible to fit either a DN 80 or a DN 100 flange on the discharge side of the baseplate.
The only difference is the pump connection, which is either 80 mm or 100 mm.

316
80-55-06

* Shaft is not in contact with pumped liquid.

14

Technical data

>

15

Technical data

>

Dimensions and installation

Channel-impeller pumps
Pump range/
type
42
S1 034 C
S1 044 C
S1 054 C
46
S1 074 AM
S1 084 AM
S1 074 AH
S1 084 AH
50
S1 094 AL
S1 134 AL
S1 094 BM
S1 134 BM
S1 114 AH
S1 134 AH
S1 094 AH
54
S1 164 AL
S1 204 M
S1 164 M
S1 164 H
S1 204 H
S1 204 AL
58
S1 314 AM
S1 244 H
S1 314 H
S1 314 L
S2 314 AL
62
S1 424 H
S1 424 M
S1 524 H
S2 424 AL
S2 524 AL
66
S1 704 H
S2 328 M
S2 408 M
S2 578 H
S2 578 M
S2 704 AM
70
S2 1004 H
S2 1004 AM
S2 1106 H
S2 1106 M
S2 1204 H
S2 1204 AM
S2 1406 H
S2 808 H
S3 578 L
S3 1406 L
S3 1406 M
S3 808 L
S3 808 M

16

Vertical dry installation (type 3)


Dimensions [mm]

DN

100/80 770 670 100 545 320 165 175 160 120 260 180 220
100/80 770 670 100 545 320 165 175 160 120 260 180 220
100/80 770 670 100 545 320 165 175 160 120 260 180 220

60
60
60
60
60
60
60

180
180
180
180

180 220
180 220
180 220

18
18
18

20
20
20

205 180 121 180


205 180 121 180
205 180 121 180

48
48
48

675 100 590 360 170


675 100 590 360 170
655 115 575 340 175
655 115 575 340 175

190
190
185
185

220
220
220
220

120
120
120
120

260
260
260
260

180
180
180
180

220
220
220
220

220
220
220
220

18
18
18
18

20 205 180 121 180


20 205 180 121 180
20 205 180 121 180
20 205 180 121 180

48
48
48
48

915
915
935
935
890
890
890

205
205
100
100
100
100
100

730
730
610
610
585
585
585

455
455
375
375
350
350
350

210
210
180
180
180
180
180

240
240
190
190
185
185
185

190
190
190
190
190
190
190

250
250
120
120
120
120
120

380
380
260
260
260
260
260

280
280
180
180
180
180
180

500 100 240 285


500 100 240 285
220 60 180 220
220 60 180 220
220 60 180 220
220 60 180 220
220 60 180 220

22
22
18
18
18
18
18

24
24
20
20
20
20
20

320
320
205
205
205
205
205

265
265
180
180
180
180
180

115
115
121
121
121
121
121

165
165
180
180
180
180
180

77
77
48
48
48
48
48

200
150
150
100
100
200

1215 1020
1180 995
1180 995
1050 960
1050 960
1215 1020

195
185
185
90
90
195

930
715
715
670
670
930

590
432
432
390
390
590

265
215
215
215
215
265

315
235
235
230
230
315

235
210
210
210
210
235

300
250
250
200
200
300

400
380
380
260
260
400

540
280
280
325
325
540

600
500
500
375
375
600

150
100
100
75
75
150

295
240
240
180
180
295

340
285
285
220
220
340

22
22
22
18
18
22

28
24
24
24
24
28

460
320
320
230
230
460

320
265
265
223
223
320

140 20
115 165
115 165
80 80
80 80
140 20

88
77
77
60
60
88

150
150
150
200
200

1365
1355
1355
1410
1410

1210
1175
1175
1225
1195

155
180
180
185
215

780
785
785
1005
1010

475
492
492
640
640

235
225
225
290
290

235
240
240
345
345

235
215
215
265
265

250
250
250
250
250

380
380
380
400
400

280
280
280
540
540

500
500
500
600
600

100
100
100
150
100

240
240
240
295
285

285
285
285
340
285

22
22
22
22
22

24 320 265
24 320 265
24 320 265
28 460 320
28 460 265

115 165
115 165
115 165
70 20
140 20

77
77
77
88
88

150
150
150
200
200

1540 1390
1555 1420
1540 1390
1585 1425
1585 1425

150
135
150
160
160

830
830
830
1130
1130

512
512
512
750
750

250
250
250
300
300

260
260
260
360
360

250
250
250
275
275

250
250
250
300
300

380
380
380
400
400

280
280
280
540
540

500
500
500
600
600

100
100
100
150
150

240
240
240
295
295

285
285
285
340
340

22
22
22
22
22

24 320 265
24 320 320
24 320 265
28 460 320
28 460 320

115 165
115 165
115 165
140 20
140 20

77
77
77
88
88

200
300
300
250
300
200

1675 1495
1715 1540
1715 1540
1700 1535
1915 1765
1670 1485

180
175
175
165
150
185

1050
1310
1310
1365
1310
975

690
790
790
840
790
550

285
440
440
445
440
350

305
525
525
480
525
380

290
355
355
400
355
320

300
400
400
350
400
300

400
400
400
400
400
400

540
620
620
620
620
540

600
700
700
700
700
600

150 295 340


150 400 445
150 400 445
150 350 395
150 400 445
150 295 340

22
23
23
23
23
22

28 460 320 140 20


28 500 420 205 270
28 500 420 205 270
28 500 370 205 270
28 500 420 205 270
28 460 320 70 20

88
88
88
88
88
88

200
200
250
300
200
200
250
250
500
500
300
500
300

1785 1610
1800 1615
1830 1665
2040 1890
1785 1610
1815 1615
1985 1820
1830 1665
2000 1680
2130 1810
2040 1890
2130 1810
2035 1890

175
185
165
150
175
200
165
165
320
320
150
320
145

955
975
1365
1310
1155
1005
1365
1365
2085
2085
1310
2085
1310

590
550
840
790
790
640
840
840
1305
1305
790
1305
790

285
350
445
440
285
285
445
445
630
630
440
630
440

285
380
480
525
285
320
480
480
715
715
525
715
525

285
320
400
355
285
290
400
400
550
550
355
550
355

300
300
350
400
300
300
350
350
600
600
400
600
400

400
400
400
400
400
400
400
400
700
700
400
700
400

540
540
620
620
540
540
620
620
900
900
620
900
620

600
600
700
700
600
600
700
700
1000
1000
700
1000
700

150
150
150
150
150
150
150
150
250
250
150
250
150

22
22
23
23
22
22
23
23
27
27
23
27
23

28
28
28
28
28
28
28
28
28
28
28
28
28

88
88
88
88
88
88
88
88
88
88
88
88
88

100
100
100
100

775
775
770
770

150
150
100
100
100
100
100

1120
1120
1035
1035
1000
1000
1000

295
295
350
400
295
295
350
350
620
620
400
620
400

340
340
395
445
340
340
395
395
670
670
445
670
445

460
460
500
500
460
460
500
500
800
800
500
800
500

320
320
575
420
390
320
370
575
655
655
420
655
420

70
70
205
205
70
70
206
205
75
75
205
75
205

20
20
30
270
20
20
270
30
30
30
270
30
270

Technical data

>

SuperVortex-impeller pumps
Pump range/
type
34
SV 014 BL
SV 014 B
SV 024 B
42
SV 034 CH
SV 044 CH

17

Dimensions [mm]
DN1

DN2

100
100
100

100
100
100

1025
1025
1025

545
545
545

425
425
425

347
347
347

217
217
217

255
255
255

270
270
270

30
30
30

M16
M16
M16

180
180
180

225
225
225

180
180
180

24
24
24

19
19
19

100
100

100
100

1055
1055

525
525

425
425

372
372

217
217

320
320

270
270

30
30

M16
M16

180
180

225
225

180
180

24
24

19
19

Technical data

>

Dimensions and installation

Channel-impeller pumps

Vertical dry installation, concrete foundation


Dimensions [mm]

Pump range/type
42
S1 034 C
S1 044 C
50
S1 094 AL
S1 134 AL
S1 094 BM
S1 134 BM
S1 114 AH
S1 134 AH
S1 094 AH
54
S1 164 AL
S1 204 M
S1 164 M
S1 164 H
S1 204 H
S1 204 AL
58
S1 314 AM
S1 244 H
S1 314 H
S1 314 L
S2 314 AL
62
S1 424 H
S1 424 M
S1 524 H
S2 424 AL
S2 524 AL
66
S1 704 H
S2 328 M
S2 408 M
S2 578 H
S2 578 M
S2 704 AM
70
S2 1004 H
S2 1004 AM
S2 1106 H
S2 1106 M
S2 1204 H
S2 1204 AM
S2 1406 H
S2 808 H
S3 1406 M
S3 808 M

18

DN1

DN2

100
100

100
100

1095
1095

600
600

425
425

425
425

257
257

335
335

270
270

300
300

M16
M16

180
180

220
220

180
180

24
24

19
19

150
150
150
150
100
100
100

125
125
100
100
100
100
100

1570
1570
1575
1575
1365
1365
1365

815
815
805
805
625
625
625

600
600
600
600
425
425
425

590
590
492
492
465
465
465

380
380
312
312
285
285
285

435
435
380
380
375
375
375

300
300
300
300
270
270
270

300
300
30 0
30 0
300
300
300

M20
M20
M20
M20
M20
M20
M20

280
280
240
240
180
180
180

250
250
250
250
220
220
220

210
210
180
180
180
180
180

24
24
24
24
24
24
24

19
19
19
19
19
19
19

200
150
150
150
150
200

200
125
125
100
100
200

1735
1645
1645
1610
1610
1735

920
840
840
815
815
920

700
600
600
600
600
700

765
575
575
570
570
765

500
360
360
355
355
500

550
445
445
440
440
550

350
300
300
300
300
350

300
300
300
300
300
300

M20
M20
M20
M20
M20
M20

295
240
240
240
240
295

250
250
250
250
-

295
210
210
180
180
295

24
24
24
24
24
24

24
19
19
19
19
24

200
150
150
250
250

125
125
125
200
200

1962
1830
1830
2075
2120

980
830
830
1065
1110

697
600
600
825
825

635
655
655
840
840

400
420
420
550
550

470
470
470
610
605

350
300
300
400
400

300
300
300
300
300

M20
M20
M20
M20
M20

295
240
240
350
350

250
250
250
-

210
210
210
295
295

24
24
24
28
28

19
19
19
24
24

150
200
150
250
250

125
125
125
200
200

2055
2140
2055
2305
2305

895
968
895
1120
1120

600
697
600
825
825

690
690
690
960
960

440
440
440
660
660

513
552
513
670
670

300
350
300
400
400

30
300
300
300
300

M20
M20
M20
M20
M20

240
295
240
350
350

250
250
250
340
340

210
210
210
295
295

24
24
24
28
28

19
19
19
24
24

250
300
300
300
300
250

200
300
300
250
300
300

2355
2805
2805
2410
2805
2345

1075
1490
1490
1110
1490
1072

825
1152
1152
855
1152
828

890
1140
1140
1190
1140
810

600
700
700
750
700
460

595
880
880
870
880
700

400
630
630
450
630
400

300
300
300
300
300
300

M20
M24
M24
M20
M24
M20

350
515
515
400
515
350

340

295
400
400
350
400
295

28
28
28
28
28
28

24
24
24
24
24
24

250
250
300
300
250
250
300
300
400
400

200
200
250
300
200
200
250
250
300
300

2470
2470
2540
2930
2470
2470
2695
2540
3085
2930

1080
1072
1110
1490
1080
1072
1110
1110
1490
1490

825
828
855
1152
825
828
855
855
1152
1152

785
810
1190
1275
785
810
1190
1190
1140
1140

500
460
750
760
500
460
750
750
700
700

570
700
870
1015
570
700
870
870
880
880

400
400
450
630
400
400
450
450
630
630

300
300
300
300
300
300
300
300
300
300

M20
M20
M20
M24
M20
M20
M20
M20
M24
M24

350
350
400
515
350
350
400
400
515
515

340
340
470
470

295
295
350
400
295
295
350
350
400
400

28
28
28
28
28
28
28
28
28
28

24
24
24
24
24
24
24
24
24
24

Technical data

Channel-impeller pumps
Dimensions [mm]
Pump range/type
S3 578 L
S3 1406 L
S3 808 L

>

19

DN1

DN2

500
500
500

500
500
500

1300
1580
1425

461
461
461

495
495
495

1845
1830
1830

1200
1200
1200

1270
1270
1270

550
550
550

620
620
620

1100
1100
1100

1180
1180
1180

700
700
700

300
300
300

28
28
28

Technical data

>

Dimensions and installation

Submerged installation, portable (types 4 and 5)

Channel-impeller pumps
Dimensions [mm]
Pump range/type
42
S1 034 C
S1 044 C
S1 054 C
46
S1 074 AM
S1 084 AM
S1 074 AH
S1 084 AH
50
S1 094 AL
S1 134 AL
S1 094 BM
S1 134 BM
S1 114 AH
S1 134 AH
S1 094 AH
54
S1 164 AL
S1 204 M
S1 164 M
S1 164 H
S1 204 H
S1 204 AL
58
S1 314 AM
S1 244 H
S1 314 H
S1 314 L
S2 314 AL
62
S1 424 H
S1 424 M
S1 524 H
S2 424 AL
S2 524 AL

SuperVortex-impeller pumps
Dimensions [mm]
Pump range/type
34
SV 014 BL
SV 014 B
SV 024 B
SV 034 B
42
SV 044 CH
SV 052 C
SV 054 CH
46
SV 074 B
SV 084 B
50
SV 092 BH
SV 122 BH

20

DN

80
80
80
80

640
640
640
640

305
305
305
305

490
490
490
490

150
150
150
150

125
125
125
125

305
305
305
305

305
305
305
305

160
160
160
160

80
100
80

725
725
725

305
305
305

490
545
490

155
150
155

155
150
155

310
300
310

355
335
355

195
190
195

100
100

755
755

305
305

580
580

175
175

220
220

395
395

385
385

240
240

100
100

930
930

350
350

555
555

180
180

180
180

370
370

460
460

290
290

Technical data

>

21

DN

100
100
100

765
765
765

305
305
305

570
570
570

175
175
175

160
160
160

335
335
335

415
415
415

270
270
270

100
100
100
100

775
775
745
745

305
305
305
305

610
610
600
600

190
190
185
185

220
220
220
220

410
410
405
405

415
415
380
380

270
270
235
235

150
150
100
100
100
100
100

1065
1065
1080
1080
1020
1020
1020

350
350
350
350
350
350
350

870
870
640
640
615
615
615

240
240
190
190
185
185
185

190
190
190
190
190
190
190

430
430
380
380
375
375
375

590
590
450
450
435
435
435

310
310
305
305
290
290
290

200
150
150
100
100
200

1125
1105
1105
1070
1070
1125

550
550
550
550
550
550

1200
915
915
775
775
1200

315
235
235
230
230
315

235
210
210
210
210
235

590
550
550
550
550
590

750
585
585
550
550
750

315
305
305
280
280
315

150
150
150
200
200

1345
1315
1315
1390
1390

550
550
550
550
550

955
975
975
1265
1265

235
240
240
345
345

235
215
215
275
275

470
550
550
620
620

640
620
620
815
815

360
340
340
380
380

150
150
150
200
200

1530
1540
1530
1555
1555

700
700
700
700
700

1070
1070
1070
1435
1435

260
260
260
360
360

250
250
250
350
350 7

510
510
510
710
10

650
645
650
805
805

370
365
370
370
370

Technical data

>

Dimensions and installation

Horizontal dry installation (type 6)

Channel-impeller pumps
Dimensions [mm]
Pump range/type
42
S1 034 C
S1 044 C
50
S1 094 AL
S1 134 AL
S1 094 BM
S1 134 BM
S1 114 AH
S1 134 AH
S1 094 AH
54
S1 164 AL
S1 204 M
S1 164 M
S1 164 H
S1 204 H
S1 204 AL
58
S1 314 AM
S1 244 H
S1 314 H
S1 314 L
S2 314 AL
62
S1 424 H
S1 424 M
S1 524 H
S2 424 AL
S2 524 AL

DN1

DN2

100
100

100
100

695
695

250
250

477
477

257
257

335
335

175
175

175
175

20
20

150
150

60
60

220
220

230
230

300
300

150
150
150
150
100
100
100

125
125
100
100
100
100
100

955
955
970
970
935
935
935

680
680
612
612
585
585
585

380
380
312
312
285
285
285

435
435
380
380
375
375
375

200
200
175
175
195
195
195

18
18
20
20
18
18
18

500
500
500
500
500
500
500

130
130
115
115
115
115
115

300
300
300
300
300
300
300

390
390
390
390
390
390
390

450
450
450
450
450

200
150
150
150
150
200

200
125
125
100
100
200

1100
1020
1020
1010
1010
1100

875
735
735
730
730
875

500
360
360
355
355
500

550
445
445
440
440
550

235
235
-

220
220
220
213
213
220

18
18
18
18

500
500
500
500
500
500

115
100
100
115
115
115

375
375
375
375
375
375

390
390
390
390
390
390

200
150
150
250
250

125
125
125
200
200

1262
1223
1223
1273
1273

815
815
815
1015
1015

775
795
795
925
925

400
420
420
550
550

536
450
450
670
670

268
-

280
250
250
267
267

18
18
18
18
18

500
500
500
500
500

115
115
115
115
115

375
375
375
375
375

390
390
390
390
390

450
450
450
450
450

150
200
200
250
250

125
125
125
200
200

1450
1440
1440
1465
1465

815
820
815
1015
1015

815
815
815
1035
1035

440
440
440
660
660

510
510
550
670
670

260
-

290
265
267 280
280

18
20
18
18
18

500
500
500
500
500

115
115
115
115
115

375
375
375
375
375

390
390
390
390
390

SuperVortex-impeller pumps
Dimensions [mm]
Pump range/type
34
SV 014 BL
SV 014 B
SV 024 B
42
SV 034 CH
SV 044 CH

22

DN1

DN2

100
100
100

100
100
100

600
600
600

260
260
260

417
417
417

217
217
217

118
118
118

20
20
20

200
200
200

190
190
190

250
250
250

100
100

100
100

635
635

250
250

437
437

217
217

102
102

20
20

150
150

57
57

220
220

230
230

300
300

Technical data

>

23

Technical data

>

Accessories

Accessories

Cast iron base plate incl. bend.

80

<- 50

100

<- 50

100

>- 54

Steel base plate excl. bend,


incl. galvanized bolts and gaskets.
*200 mm higher than product number 96066479

Cast iron bend, 90

PN 10.

Guide bar bracket


Upper holder in stainless steel for twin guide rails.

Non-return valve
Cast iron ball-type, PN 10.

>- 54
>- 54
>-46
>-46
>-46

<- 50
>- 54

DN500

DN300

DN600

The ASM 3 alarm status module is designed for monitoring motor temperature and possible moisture leaks
in submersible pump motors. The ASM 3 decodes the
internal protection circuit P1-P2 of the pump in such a
way that the thermal alarm and moisture alarm, which
are normally connected in series, can be separated. The
ASM 3 registers the status of the internal protection
circuit of the pump. The pump must be prepared for ASM 3.

96066471
96066466

96066481

96066496
96066472
96066467
96066482
96066493
96066479
96066478
96065432
96066503

96060928
96060929
96060930
96060931
96060934
96060935
96060938
96060940
96060942
96060943
96060944
96060946
96060947
96060950
96060951
96060952
96067990
96067992
96457261
96067996
96067999
96067999
96068001
96459313

SARI 2

Prope for seal condition monitoring


OCT3460010
The OCT monitoring probe is inserted in the oil
OCT3460020
chamber. It ensures that any seal leakage is registered OCT3460030
immediately. The OCT probe is available for the
pump ranges 50, 54 and 58

24

All ranges

96060434

ASM3 230 V

All ranges

96069934

96003332
96003695
96003421
96003536
96003338
Max. load 1100 kg
Max. load 2000 kg
Max. load 3200 kg
Max. load 8000 kg

96468285
96468290
96468295
96468300

Controller type, electrical data and product numbers

Level controller

Description

LC 107 controller, pneumatic version


with level bells and tube for 1 pump
3 x 400 V, direct-on-line starting.
LCD 107 controller, pneumatic version
with level bells and tube for 2 pumps
3 x 400 V, direct-on-line starting.
LC 108 controller for float switches
for 1 pump 3 x 400 V, direct-on-line
starting.

96060975
96060973
96060976
96060977
96004421
96004422

LC 108 controller for float switches


for 1 pump 3 x 400 V, star-delta
starting.
LCD 108 controller for float switches
for 2 pumps 3 x 400 V, direct-on-line
starting.
LCD 108 controller for float switches
for 2 pumps 3 x 400 V, star-delta
starting.

96061602

All ranges

ASM3 110 V

Lifting chain
Galvanized lifting chain with lifting link
and safety hook, length 6 m.

Automatic water in oil and motor insulation resistance check


The SARI 2 monitors the motor insulation resistance as
well as the water content in the oil chamber between
the two mechanical shaft seals. In case of deterioration
of the motor insulation, the SARI 2 will provide an early
warning, allowing for the necessary prevenative maintenance before any motor damage occurs.

Product
number

Float switch with 10 m cable


Float switch with 20 m cable
Float switch with 10 m cable (for explosion-proof version)
Float switch with 20 m cable (for explosion-proof version)
Bracket for two float switches

Additional information

DN80
DN100
DN150
DN200
DN250
DN300

Pump range

Alarm status monitoring

96066511

Type

Description

96066506

150

Auto-coupling

DN250

200
80
100
150
200
250
300
300*
500
600
DN
80/80
80/100
100/100
100/150
150/150
150/200
200/200
200/300
250/250
250/300
250/350
300/300
300/400
400/500
500/500
600/600
80/100
80/100
150
200
250
300
500
600
Type

DN200

DN150

DN80

Pump
range

DN100

Pump
outlet
[mm]

Auto-coupling

Product
number

Base plate discharge flange PN10

Description

Operating
current
per pump
[A]

Mains
switch
required
[A]

1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0
1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0
1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0
6.4 - 20.0
20.8 - 30.0
20.8 - 59.0
24.2 - 72.0
1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0
6.4 - 20.0
20.8 - 30.0
20.8 - 59.0
24.2 - 72.0

25
25
25
40
25
25
25
40
25
25
25
40
25
40
80
**
25
25
25
40
25
40
80
**

Product number
Grundfos
With
With
product no. Hour counter Start counter

With
Combined
hour and
start counter

*
*
*
*
*
*
*
*
96 43 39 92
96 43 39 96
96 43 40 00
96 43 40 04
*
*
*
*
96 43 40 40
96 43 40 44
96 43 40 48
96 43 40 52
*
*
*
*

*
*
*
*
*
*
*
*
96 43 39 94
96 43 39 98
96 43 40 02
96 43 40 06
*
*
*
*
96 43 40 42
96 43 40 46
96 43 40 50
96 43 40 54
*
*
*
*

96 00 24 67
96 00 24 68
96 00 24 69
96 00 24 70
96 00 24 74
96 00 24 75
96 00 24 76
96 00 24 77
96 43 39 91
96 43 39 95
96 43 39 99
96 43 40 03
96 43 79 28
96 43 79 50
96 43 79 70
96 43 79 90
96 43 40 39
96 43 40 43
96 43 40 47
96 43 40 51
96 43 80 32
96 43 80 52
96 43 80 72
96 43 80 92

*
*
*
*
*
*
*
*
96 43 39 93
96 43 39 97
96 43 40 01
96 43 40 05
*
*
*
*
96 43 40 41
96 43 40 45
96 43 40 49
96 43 40 53
*
*
*
*

* Has to be bought separately. Please see Accessories on page 26.


** Depends on local standards.
Cable length 10 m
Cable length 20 m
Cable length 30 m

96476770
96476771
96476772

(Cont. next page).

Accessories

>

25

Accessories

>

The Grundfos wastewater range

Accessories

Brochures available (50 Hz)

Product number
Level
controller

Description

LC 110 controller for electrodes for 1 pump 3 x 400 V,


direct-on-line starting.
LCD 110 controller for electrodes for 2 pumps 3 x 400 V,
direct-on-line starting.

Operating
current
per pump
[A]

Mains
switch
Grundfos
required product no.
[A]

1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0
1.0 - 2.9
1.6 - 5.0
3.7 - 12.0
12.0 - 23.0

25
25
25
40
25
25
25
40

96 48 41 01
96 48 41 02
96 48 41 03
96 48 41 04
96 48 41 09
96 48 41 10
96 48 41 11
96 48 41 12

With
hour counter

With
combined
hour and
start counter

With
battery

96 48 37 07
96 48 37 08
96 48 37 09
96 48 37 10
96 48 37 15
96 48 37 16
96 48 37 17
96 48 37 18

96 48 37 23
96 48 37 24
96 48 37 25
96 48 37 26
96 48 37 31
96 48 37 32
96 48 37 33
96 48 37 34

96 48 37 62
96 48 36 63
96 48 37 64
96 48 37 65
96 48 37 70
96 48 36 71
96 48 37 72
96 48 37 73

With
With
combined
hour counter hour and
and battery start counter
and battery

96 48 37 78
96 48 37 79
96 48 37 80
96 4837 82
96 48 37 87
96 48 37 88
96 48 37 89
96 48 37 90

96 48 37 95
96 48 37 96
96 48 37 97
96 48 37 98
96 48 38 13
96 48 38 14
96 48 38 15
96 48 38 16

Heavy-duty submersible
sewage pumps 1.65 - 29 kW

Heavy-duty submersible
sewage pumps 15 - 155 kW

Brochure covers the Grundfos range


of submersible channel-impeller
pumps from 1.65 kW up to 21 kW
and SuperVortex pumps up to
29 kW. All designed for handling
unscreened raw sewage.

Brochure covers the Grundfos


range of sewage pumps from 15 kW
up to 155 kW for handling of raw
sewage in heavy-duty applications.

Super-heavy-duty
submersible sewage and
raw water pumps

Accessories for LC/LCD 110


Picture

Brochure covers the Grundfos range


of super-heavy-duty channel
pumps, axial flow pumps, and propeller pumps from 7.5 kW up to
520 kW.

Product
number

Description
1 electrode with 10 m cable

96 07 62 89

3 electrodes with 10 m cable

96 07 61 89

4 electrodes with 10 m cable

91 71 34 37

Bracket for electrodes

91 71 31 96

Portable
dewatering pumps
Brochure covers the Grundfos range
of portable dewatering pumps (DW)
from 0.8 kW to 20 kW for pumping
raw water with abrasives.
Accessories

Picture

Battery back-up

Description

Product
number

9.6 V

96 00 25 20

Lifting stations
Brochure covers Grundfos lifting
stations for individual as well as
multi-user applications.

Hour counter

400 V

96 00 25 15

Start counter

400 V

96 00 25 17

The KP/AP stainless


steel range
Brochure covers a wide range of
high quality stainless steel pumps
for a variety of domestic and
commercial applications.

Stainless steel heavy-duty


submersible pumps
Brochure covers the Grundfos
range of heavy-duty stainless
steel pumps (SEN) for aggressive
and corrosive environments.

LC/LCD level controllers


Brochure covers the Grundfos
range of controls for the wastewater pumping systems.

Mixers and flowmakers

Combined hour and start counter

External mains switch for supply cable

400 V

96 00 25 19

25 A

96 00 25 11

40 A

96 00 25 12

80 A

96 00 25 13

LC-Ex4 safe barrier, for use in potentially explosive enviroments,


for float switch applications, for use with the above mentioned float switches

26

Brochure covers the new range


of mixers and flowmakers for
optimal control of liquids and
solids throughout the wastewater treatment process.

Submersible sewage
grinder pumps
Brochure covers the new
Grundfos range of sewage grinder
pumps (SEG) for pumping of
wastewater with toilet discharge.

96 44 03 00

Accessories

>

27

The range

>