Automatic synchronization and load sharing of two generating sets
controlled by a single module
GENERAL POINTS DUOGEN is a microprocessor based single module which gathers the control of two generators. DUOGEN carries out manual and auto synchronization, isochronous load sharing or droop load sharing. DUOGEN integrates the following features: - 1 digital input for auto synchronization. - 1 sync check relay is checking phase, frequency and voltage differences. - 1 'Load shedding' output relay is calling for need of power, allowing a better power plant global efficiency. - 2 Isochronous kW sharing controls. - 2 Iso-voltage kVAR sharing controls. - 2 Reverse power protections. INPUTS/OUTPUTS FOR EACH GENSET 3 phases genset voltages (3 or 4 wires, 100 to 440 VAC). 3 phases genset currents (1A or 5A CTs). 1 digital input: feedback of the genset breaker position. 1 digital input: unload request (adjustable ramp time). 1 analogue input for speed control ( 5 VDC or potentiometer). 2 output relays: trip request and reverse power protection. 1 analogue output: active power monitor (0-5V or 0-1mA adjustable). Proportional and integral gain pot for synchronization. 1 analogue output for speed control adjustable with Gain pot and Offset pot, compatible with most electronic governors (Barber Colman, Woodward, GAC, Heinzmann, Ambac, DDEC, MDEC). 1 analogue output for voltage control, adjustable with Gain pot and Offset pot, compatible with most AVR (Leroy Somer, Stamford, Basler). COMMON INPUTS/OUTPUTS 'SYNC OK' output relay: always active. Stays open in dead bus conditions. The coupling authorization safety relay is authorizing the coupling only when differences in frequency, voltage and phase meet the requirements of the installation. 'LOAD SHEDDING' output relay: active when application needs the power of the two gensets. 1 digital input: remote synchronization request. 1 digital input: droop mode. Stability and load sharing pot. for ILS.
APPLICATIONS Two gensets in change over application: Manual mode: potentiometer speed for synchronization and kW control. Auto mode: automatic synchronization and load sharing. Two gensets in change over application + no break return to mains with soft load transfer: Add a C2S-III (CRE module, reference A25W0) to synchronize the power plant to mains. Gaz, fuel, and turbines: Duogen can be installed regardless the type of prime mover and fuel.
CHARACTERISTICS Weight - Size: 1.5 kg - 200x275x26 mm Measuring voltage and current input: Reference Switch GE 1 & 2 pos. 1 110 VAC / 5AAC pos. 2 240 VAC / 5AAC
A40R0 pos. 3 440 VAC / 5AAC
Frequency: 50 or 60 Hz. Output relay contacts: Volt free contacts, 5 A at voltage of 250 VAC, maximum cutting voltage 440 VAC. Switched power on resistive load, 1250 VA .
ENVIRONMENT Power supply: 9 to 40VDC 10 Watts Operating temperature: -20 to +85 C. Mounting: can be mounted in all positions. Humidity: will operate normally in humid conditions (Tropic-proof circuits). CE Mark: Duogen is in conformity with European CE Mark requirements. WIRING DIAGRAM DUOGEN AVR Speed governor -Alim 17 Gen1 Speed out 23 Gen1 I1- 24 Gen1 I2+ 25 Gen1 I2- 26 Gen1 I3+ 27 Gen1 I3- 41 S y n c h
O K N O 40 16 Gen1 Speed CCW - 15 Gen1 Speed CW + 14 1 P o w e r
s u p p ly
+ 2 p o w e r
s u p p ly
- 18 Gen1 Speed Ref 20 Gen1 AVR out + 21 Gen1 AVR out - 28 Gen1 L1 29 Gen1 L2 30 Gen1 L3 31 Gen1 N (optional) 22 Gen1 I1+ Chassis isolated from power supply From speed governors 4 mm wire 19 P1 P2 S1 S2 L2 N L3 L1 analog 100 - 480 V 5 A 48 Gen2 Speed out 57 Gen2 I3- 56 Gen2 I2+ 55 Gen2 I2- 54 Gen2 I1+ 53 Gen2 I1- 49 Gen2 Speed ref 51 Gen2 AVR out + 52 Gen2 AVR out - 50 59 Gen2 L1 60 Gen2 L2 61 Gen2 L3 62 (optional) Gen2 N 58 Gen2 I3+ G2 Surge diverter 3 G e n 1
b r e a k e r
I N 4 G e n 2
B r e a k e r
I N 5 G e n 1
U n lo a d 37 G e n 2
U n lo a d 36 S y n c
in G e n 1
t r ip
o u t N O G e n 2
t r ip
o u t N O G e n 2
R e v .
k W N O 11 12 Gen1 kW out +5V Gen1 kW out 0 Power monitor 0-5V or 0-1mA L o a d
s h e d d in g N O AVR Speed governor 6 D r o o p Gen1 Speed setpoint +/- 5V or potentiometer 16 Gen2 Speed CCW - 15 Gen2 Speed CW + 14 Gen2 Speed setpoint 38 39 G e n 1
R e v .
k W N O 13 Gen1 kW out 1mA 42 43 Gen2 kW out +5V Gen2 kW out 0 44 Gen2 kW out 1mA - Battery + 5Amps Power monitor 0-5V or 0-1mA P1 P2 S1 S2 P1 P2 S1 S2 analog F F F Load C2S III Auto Mains Failure L2 N L3 L1 +/- 5V or potentiometer analog analog F 100 - 480 V Surge diverter F F F P1 P2 S1 S2 P1 P2 S1 S2 P1 P2 S1 S2 5 A -Alim to pin 36 G2 breaker in G2 breaker in G1 breaker in -Alim to pin 5 G1 breaker in Breaker control 35 34 32 33 10 9 7 8 G1