Local Integration Guide

Main Job on site:


1 Use Weblmt to login the EnodeB
2 Add the OM link and check the link status
3 Add the board and GPS information; Check the GPS Status and VSWR of the
ports.

Steps of job:
1 Use Weblmt to login the eNodeB
Use the Ethernet cable to connect to ETH port of LMPT board.
Configure the IP 192.168.0.2 on laptop.

Use IE and visit the website:
http://192.168.0.49/
Use the username admin; Password admin123 to login the eNodeB.

2 Add the OM link and check the link status
SET DHCPSW: SWITCH=DISABLE;


DSP ETHPORT: SN=7, SBT=BASE_BOARD;


Local Configuration Negotiation Mode = AUTO
Local Actual Negotiation Mode = AUTO






If you find wrong configuration, please use SET ETHPORT to modify as the picture
below:


ADD DEVIP:


LST DEVIP:




LST DEVIP Result


ADD VLANMAP:



LST VLANMAP:









LST VLANMAP Result:



ADD OMCH:






[important step] PING
1. PING from Local IP to GW IP
2. PING from Local IP to destination IP
Please make sure GW IP and destination IP are reachable.



DSP OMCH



DSP OMCH Result:


3 Add the board and GPS information; Check the GPS Status and
VSWR of the ports.
Run these commands as below:
RMV RRU: CN=0, SRN=60, SN=0;
RMV RRU: CN=0, SRN=61, SN=0;
RMV RRU: CN=0, SRN=62, SN=0;
RMV RRU: CN=0, SRN=63, SN=0;
RMV RRU: CN=0, SRN=64, SN=0;
RMV RRU: CN=0, SRN=65, SN=0;
RMV RRU: CN=0, SRN=66, SN=0;
RMV RRU: CN=0, SRN=67, SN=0;
RMV RRU: CN=0, SRN=68, SN=0;
RMV RRU: CN=0, SRN=69, SN=0;
RMV RRU: CN=0, SRN=70, SN=0;
RMV RRU: CN=0, SRN=71, SN=0;
RMV RRU: CN=0, SRN=72, SN=0;
RMV RRU: CN=0, SRN=73, SN=0;
RMV RRU: CN=0, SRN=74, SN=0;
RMV RRU: CN=0, SRN=75, SN=0;
RMV RRU: CN=0, SRN=76, SN=0;
RMV RRU: CN=0, SRN=77, SN=0;

RMV RRUCHAIN: RCN=0;
RMV RRUCHAIN: RCN=1;
RMV RRUCHAIN: RCN=2;
RMV RRUCHAIN: RCN=3;
RMV RRUCHAIN: RCN=4;
RMV RRUCHAIN: RCN=5;
RMV RRUCHAIN: RCN=6;
RMV RRUCHAIN: RCN=7;
RMV RRUCHAIN: RCN=8;
RMV RRUCHAIN: RCN=9;
RMV RRUCHAIN: RCN=10;
RMV RRUCHAIN: RCN=11;
RMV RRUCHAIN: RCN=12;
RMV RRUCHAIN: RCN=13;
RMV RRUCHAIN: RCN=14;
RMV RRUCHAIN: RCN=15;
RMV RRUCHAIN: RCN=16;
RMV RRUCHAIN: RCN=17;


RMV BRD: CN=0, SRN=0, SN=0;
RMV BRD: CN=0, SRN=0, SN=1;
RMV BRD: CN=0, SRN=0, SN=2;
RMV BRD: CN=0, SRN=0, SN=3;
RMV BRD: CN=0, SRN=0, SN=4;
RMV BRD: CN=0, SRN=0, SN=5;
RMV BRD: CN=0, SRN=0, SN=16;
RMV BRD: CN=0, SRN=0, SN=18;
RMV BRD: CN=0, SRN=0, SN=19;


ADD BRD: CN=0, SRN=0, SN=3, BT=LBBP, WM=RAT_TDD;
ADD BRD: CN=0, SRN=0, SN=16, BT=FAN;
ADD BRD: CN=0, SRN=0, SN=18, BT=UEIU;
ADD BRD: CN=0, SRN=0, SN=19, BT=UPEU;

ADD RRUCHAIN: RCN=0, TT=CHAIN, HCN=0, HSRN=0, HSN=3, HPN=0;
ADD RRUCHAIN: RCN=1, TT=CHAIN, HCN=0, HSRN=0, HSN=3, HPN=1;

ADD RRU: CN=0, SRN=60, SN=0, TP=TRUNK, RCN=0, PS=0, RT=MRRU, RXNUM=4,
TXNUM=4, RS=LO_TD, ALMPROCSW=ON;
ADD RRU: CN=0, SRN=61, SN=0, TP=TRUNK, RCN=1, PS=0, RT=MRRU, RXNUM=4,
TXNUM=4, RS=LO_TD, ALMPROCSW=ON;


ADD GPS: SN=7, PRI=1;
SET CLKSYNCMODE: CLKSYNCMODE=PHASE;




DSP GPS:; (Make sure the GPS Card State is Normal; And the GPS Satellites Traced is
larger than 8.)


STR VSWRTEST:;(Make sure the VSWR result of RRU RF port connected is lower than
1500.)