PROFIBUS DP/DPV1
Ethernet
F
Remote
I/O
M
PID
M
Data Sheet
10/630.47 EN
Industrial
Devices overview
PROFIBUS DP
IT
Field
IT
Flowmeter
Field
IT
Electrical Actuator
Field
IT
Redundancy Link Module
Inform
IT
Process Recorder
Analyze
IT
Analyzer
Power
IT
Power Transducer
Protect
IT
MNS Motor Management INSUM
Drive
IT
Frequency Converter
Drive
IT
DC Drives
Control
IT
Process Controller
Control
IT
Motor Management, Motor Starter
Control
IT
Remote I/O and I/O System
Control
IT
Distributed Automation
2
Devices overview 10/630.47 EN
PROFIBUS DP
Field
IT
Flowmeter
FXM2000-DM. (COPA/MAG-XM) FXE4000 (COPA/MAGXE) FXM2000-DC. (COPA/MAGCM)
Data Sheet D184S031U02 D184S044U02 D184S007U02
Internet www.abb.com/instrumentation www.abb.com/instrumentation www.abb.com/instrumentation
Industrial
IT
enabled
Application Electromagnetic Flowmeter.
Suitable for universal use. Available in
compact or split architecture.
Accuracy:
0.4 % (optionally 0.2 %) of rate
Meter size:
DN 3...2400 (flange)
DN 1...100 (variable connections)
Electromagnetic Flowmeter.
Affordable standard instrument
in flanged and adapterflanged
versions.
Option: Stainless steel with variable
process connections.
Precision:
0.5 % of rate
Range:
DN 3...1000 (flanged)
DN 3...100 (adapterflanged)
Electromagnetic Flowmeter.
With capacitive electrodes,
used with measured mediums
with insulating deposits and low
conductivity > 0.05 s/cm.
Accuracy:
1 % of rate
Meter size:
DN 25...300 (flange)
Ambient temperature 25...+60 C 25...+60 C 25...+60 C
Type of protection IP 67 (IP 68) IP 67 (IP 68) IP 67 (IP 68)
Explosion protection
Registration CE 3A, EHEDG, CE CE
Physics RS 485 RS 485 RS 485
Protocol PROFIBUS DP PROFIBUS DP PROFIBUS DP
Max. Baud Rate 1.5 Mbit/s 1.5 Mbit/s 1.5 Mbit/s
Ident. No. 6666 HEX 6666 HEX 6666 HEX
PNO Certificate No.
Bus adress
local adjustment
central adjustment
0...126 (default 126)
Keypad
Software (e.g.: PLC)
0...126 (default 126)
Keypad
Software (e.g.: PLC)
0...126 (default 126)
Keypad
Software (e.g.: PLC)
Data length cyclical
read
write
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
Profil
Transducer Block
Function Block
(only for profil
conforming devices)
DP device only:
rate, status, counter
DP device only:
rate, status, counter
DP device only:
rate, status, counter
Device configuration
central adjustment
local adustment
Software (e.g.: PLC)
Keypad and display
Software (e.g.: PLC)
Keypad and display
Software (e.g.: PLC)
Keypad and display
External supply Yes Yes Yes
3
Devices overview 10/630.47 EN
PROFIBUS DP
Field
IT
Flowmeter
FSM1000 FMC2000-MM2 (TRUMASS) FMC2000-MM2 (TRIOMASS)
Data Sheet D184S034U02 D184S020U02 D184S068U02
Internet www.abb.com/instrumentation www.abb.com/instrumentation www.abb.com/instrumentation
Industrial
IT
enabled
Application Electromagnetic Flowmeter.
Especially suitable for fast response
times, liquids with higher
concentration of hard solid particles,
twophase fluids.
Accuracy:
1 % of rate
Meter size:
DN 3...1000 (flange)
DN 1...100 (variable connections)
Coriolis Mass Flowmeter.
Simultaneous determination of mass,
density and temperature;
singletubedesign, selfemptying,
spacesaving, robust, inexpensive.
Temperature of fluid:
50...+180 C
Accuracy:
Flow: 0.25 % of rate
Density: 5 g/l, 1 g/l
Meter size: DN 10, DN 15, DN 20,
DN 25, DN 40, DN 50
Coriolis Mass Flowmeter.
Simultaneous determination of mass,
density and temperature;
paralleltubedesign, selfemptying,
spacesaving, robust, inexpensive.
Temperature of fluid:
50...+180 C
Accuracy:
Flow: 0.15 %, 0.25 %, 0.4 % of rate
Density: 5 g/l, 1 g/l
Meter size: DN 10...DN 150 (...6)
Ambient temperature 25...+60 C 20...+60 C 20...+60 C
Type of protection IP 67 (IP 68) IP 67 IP 67
Explosion protection
Registration CE CE 3A, CE
Physics RS 485 RS 485 RS 485
Protocol PROFIBUS DP PROFIBUS DP PROFIBUS DP
Max. Baud Rate 1.5 Mbit/s 1.5 Mbit/s 1.5 Mbit/s
Ident. No. 6666 HEX 6666 HEX 6666 HEX
PNO Certificate No.
Bus adress
local adjustment
central adjustment
0...126 (default 126)
Keypad
Software (e.g.: PLC)
0...126 (default 126)
Keypad
Software (e.g.: PLC)
0...126 (default 126)
Keypad
Software (e.g.: PLC)
Data length cyclical
read
write
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
fix 16 Byte
Profil
Transducer Block
Function Block
(only for profil
conforming devices)
DP device only:
rate, status, counter
DP device only:
rate, status, counter
DP device only:
rate, status, counter
Device configuration
central adjustment
local adustment
Software (e.g.: PLC)
Keypad and display
Software (e.g.: PLC)
Keypad and display
Software (e.g.: PLC)
Keypad and display
External supply Yes Yes Yes
4
Devices overview 10/630.47 EN
PROFIBUS DP
Field
IT
, Analyze
IT
Flowmeter Analyzer Process Controller
FMT500-IG (Sensyflow iG) Advance Optima + PKV30-DPS D100 (Digitric 100)
Data Sheet 10/146.41 EN 10/241.10 EN 10/616.11 EN
Internet www.abb.com/instrumentation www.abb.com/analytical www.abb.com/control
Industrial
IT
enabled Yes Yes
Application Thermal mass flowmeter for air
and gases, determination of mass
flow / standard volume flow and
gas temperature.
Turn down ratio: 1:150
Temperature of fluid:
25...+300 C
Accuracy:
0.9% of reading + 0.05 % fs
Meter size:
DN 25...3000 mm (1"...120")
Modular product line for process
analytics and emission monitoring.
Offers a range of different analytical
principles: NDIR, IR UV, thermal
conductivity, O
2
(paramagnetic)
and flame ionization measurement
of Hydrocarbons (FID).
Industrial Controller,
1channel (1 PID algorithms).
Multifunctional, flexible I/O
configuration, extensive function library
with preconfigured control strategies.
Frontal dimensions:
96 mm x 96 mm
Ambient temperature 25...+50 C 20...+50 C (45 C Uras) 0...50 C
Type of protection IP 67 IP 20 / IP 54 Front.: IP 65; hous.: IP 30; term.: IP 20
Explosion protection II 2(1) G EEx de [ia] ib II C T3; II 2 D EEx
Registration CE, ATEX, FM, CSA CE, TV CE
Physics RS 485 RS 485 RS 485
Protocol PROFIBUS DPV1 PROFIBUS DP PROFIBUS DPV1
Max. Baud Rate 1.5 Mbit/s 12 Mbit/s 1.5 Mbit/s
Ident. No. 05CA HEX 7503 HEX 9651 HEX
PNO Certificate No. be applied Z00413
Bus adress
local adjustment
central adjustment
0...126 (default 126)
Keypad
Software (e.g.: SMART VISION)
0...99
Switches
1...125 (default 1)
Buttons, IBISR+ via TTL/RS 232/485
1...125 (default 1)
Keypad, IBISR+ via TTL/RS 232/485
1...125 (default 1)
Keypad, IBISR+ via TTL/RS 232/485
Keypad or Software
Parapoint 100 via RS 485
Keypad or Software
Parapoint 200 via RS 485
Keypad or Software
Paraline 200 via RS 485
External supply Yes Yes Yes
7
Devices overview 10/630.47 EN
PROFIBUS DP
Power
IT
, Field
IT
Power Transducer Gateway
ESU (Contrans E SU) BusCon
Data Sheet 10/282.54 EN 10/497.20 EN
Internet www.abb.com www.abb.com
Industrial
IT
enabled Yes Yes
Application Universal Power Transducer.
Measurement of all power current
variables in single or three phase
mains, mains synchronization and
energy totalization.
PROFIBUS DP Gateway for
Recorder and Power Transducer.
Transmission of measured variables
without delay, 1...15 Recorders/Power
Transducers connectable.
Ambient temperature 20...+60 C 0...45 C
Type of protection IP 40 (terminals IP 20) IP 20
Explosion protection
Registration CE CE
Physics RS 485
Protocol PROFIBUS DP
Max. Baud Rate 12 Mbit/s
Ident. No. 2079 HEX
PNO Certificate No.
Bus adress
local adjustment
central adjustment
via gateway BusCon
0...126 (default 1)
Switch
Device configuration
central adjustment
local adustment
Switches
External supply Yes Yes
8
Devices overview 10/630.47 EN
PROFIBUS DP
Field
IT
, Drive
IT
Electrical Actuator Frequency Converter
Contrac ACS 160
Data Sheet 10/681.51 EN, 10/682.73 EN, 10/68
8.22 EN, 10/688.26 EN, 10/688.27 NE
3BFE64383671 EN
Internet www.abb.com/instrumentation www.abb.com/motors&drives
Industrial
IT
enabled Yes Yes
Application Intelligent electrical continuous
Actuators for modulating control.
Type: PME120, RHD..., LME620, RSD...
Part turn drives from 100...16000 Nm;
Linear drives from 4...200 kN;
digital communication, PC control.
Meter size:
Continuous positioning, precise,
longlived
Frequency Converter.
ACS 160 for universal applications,
in book shape, configuration possible
for constant and squarelaw load
torques.
Power connection:
3phase 380...500 V, 10 %,
50/60 Hz, 0.55...2.2 kW
Motor connection:
0...250 Hz
Ambient temperature 30...+65 C 10...+40 C (50 C)
Type of protection IP 66 IP 65 / NEMA 4
Explosion protection
Registration CE UL, CSA, CE
Physics RS 485
Protocol PROFIBUS DP via communication module
Max. Baud Rate 1.5 Mbit/s CFB-PDP
Ident. No. 9655 HEX
PNO Certificate No.
Bus adress
local adjustment
central adjustment
2...126 (default 126)
SMART VISION via RS 232
2...126 (default 2)
Panel, Software DriveWindows Light
2...126 (default 2)
Panel, Software DriveWindows
2...126 (default 2)
Panel, Software DriveWindows
2...126 (default 2)
Panel, Software CMTool
2...126 (default 2)
Panel, Software DriveWindows
.
6digit LCDdisplay:
For a clear display of data from all
128 connected field devices.
Encoder wheel and funtion keys:
Simple and clear menudriven
operation.
Ambient temperature 5...+55 C 5...+55 C 5...+70 C
Type of protection IP 20 IP 20 IP 30
Explosion protection PTB Ex 0130061 PTB Ex 0130061
Registration CE, IEC 4391, PTB CE, IEC 4391, PTB CE, IEC 4391
Physics
Protocol
Max. Baud Rate
Ident. No.
PNO Certificate No.
Bus adress
local adjustment
central adjustment
via INSUM
-Gateway
Data length cyclical
read
write
Profil
Transducer Block
Function Block
(only for profil
conforming devices)
Measurement: current, temperature
Operating commands:
Messages: time meter, status, service,
warnings, errors, etc.
Measurement: current, voltage, power,
cosphi, temperature
Operating commands:
Messages: time meter, status, service,
warnings, errors, etc.
see MCU1 and MCU2
Device configuration
central adjustment
local adustment
DTM in preparation
Via Software
OS on Ethernet TCP/IP
DTM in preparation
Via Software
OS on Ethernet TCP/IP
2...99 (default 0)
Switch, software via adapter
2...99 (default 0)
Switch, software via adapter
0...126 (default 0)
Switch
0...79
Switch
0...126
DIP switch
0
.
4
7
E
N
R
e
v
.
A
The Industrial
IT
wordmark and all mentioned
product names in the form XXXXXX
IT
are registered
or pending trademarks of ABB.
ABB has Sales & Customer Support
expertise in over 100 countries worldwide.
www.abb.com/fieldbus
E-Mail: fieldbus.support@de.abb.com
The Companys policy is one of continuous product
improvement and the right is reserved to modify the
information contained herein without notice.
Printed in the Fed. Rep. of Germany (12.02)
ABB 2002
ABB Ltd.
Howard Road, St. Neots
Cambridgeshire, PE19 8EU
UK
Tel: +44 (0)1480 475321
Fax: +44 (0)1480 217948
ABB Inc.
125 E. County Line Road
Warminster, PA 18974
USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183
ABB Automation Products GmbH
Hoeseler Platz 2
42579 Heiligenhaus
Germany
Tel: +49 2056 125533
Fax: +49 2056 125095