Vous êtes sur la page 1sur 2

You’ll find outstanding features

available on the Specialist


Walk-in models
Cab-Body Access Door Seagrave Cab
• Door located between the cab and the • Seagrave custom cabs
front of the body • Stainless steel enclosed
• Features a complete bellows-type seal
• Convenient sideways-sliding open and
close design
cage design
• Stainless steel or aluminum
cab construction
Specialist
• Built in window for visual contact from • Full-tilt, split-tilt and extended tilt
either side of door cab designs — all from 2 to 10 Walk-In and Walk-Around Rescues with Seagrave Custom Chassis
person capacity Seagrave Service
• Minimum 58" floor-to-ceiling height Seagrave Fire Apparatus
Body Floor in cab
• Non-slip treadplate over 3/4" plywood
• Flat or optional 8" and 14" raised roofs
are sold and serviced by a
sub-floor nationwide, factory-trained
• Minimizes noise through floor
dealer organization that is
• Helps retain interior temperatures Chassis readily available to assist
• Meritor (MFS) front axle,
Independent Front Suspension, and with all your service and
Body Ceiling and Walls Large double-door access
• Rigid-foam insulated
FWD semi-elliptical, constant-rate, technical support needs for
spring front suspensions the total Seagrave product;
• 1/4" washable white vinyl coated, medium
• Reyco, Neway, Hendrickson and
density fiberboard
FWD semi-elliptical constant rate
including cabs, chassis,
• A bright interior that’s easy to keep clean rear suspensions bodies, pumps, ladders and
• Drum or 17" EX225H disc brakes aerial components. In
addition, these professionals
Interior Lighting
• Windows
• Dynamic variable section frames
available can help with specifying all Specialist
• Skylight • Specially designed front
bumper frames
the many features and
• LED dome lights
options on your new custom
• Mini fluorescent lights
Seagrave. Your local
Available Engines Seagrave dealer can be
HVAC (Cab Dependent)
Walk-in hallway looking towards the rear • Detroit Series 60
identified on the Seagrave
• Two Heating/AC combination units:
 5,000 BTU heating • CAT C9, C13 web site, or by calling us.
 25,000 BTU cooling
• Cummins ISL, ISM

Action Wall Electrical System


• Wired and strengthened wall for mounting • All NFPA compliant
and accessing various switches and • Seagrave Custom Chassis
• 110/220V and duplex receptacles
controls
• Generators — hydraulic, diesel and
• Stainless Steel and Aluminum Cabs
PTO driven
Electrical Systems • Stainless Steel Bodies
• Heavy-duty 12-volt wiring
• Line voltage supplied by 120/240V power
source
• Square D 24-unit circuit breaker
• Shore-line system to all 120VAC electrical
devices to be powered from both the on- Phone: 715-823-2141
board generator and from shore power
Fax: 715-823-5768
Effective 3/06 Specifications subject to change without Clintonville, WI
notice. Photos shown may include optional equipment and
accessories, and may not include all standard equipment. www.seagrave.com
Skylight/roof access
© 2006 Seagrave Fire Apparatus, LLC All rights reserved.
SG-128 4/06 10M INPR
A Variety of Built-in
Specialty Items are

Specialist Custom-constructed
compartment doors, readily
Available on the
Seagrave Specialist
Rescues
available. Shown here is a • Desks
Versatile and dependable, ready built-in refrigerator with
diamond-plated door.
• Radio cabinets
• Library
to meet a future of possibilities Hinged exterior compartment door with locking Roll-up interior compartment doors provide Louvered interior compartment doors allow • Refrigerator
D-ring handle provides secured storage instant access to stored equipment pharmaceuticals access to heat and A/C
• Air cylinder storage
Build your Seagrave Specialist Rescue • Suit compartments
from the ground up with the space, the • Benches Built-in cabinets, desk, sliding window, dry-erase
compartmentalization, the power, the board, cab-body access door
functional variety and mission performance Specialty storage compartments designed for
Compartment Construction all your needs
to adequately handle any situation your
• Sweep out floor design
department may face. Through this custom
• Spatter paint interior
design approach, you’ll have control over • Heavy-duty, roll-up or lap-type
every detail from bumper to bumper — double panel doors
including your budget. • Scuffplating for interior doors
available Exterior weatherproof port
From cab construction and chassis • Floor options: Dri-Dek, Turtle Tile for connecting phone, data
suspension to doorways and stairways … • Adjustable shelves, roll-out trays, transmissions or satellite
toolboards, dividers and pegboard communications
from floors and ceilings to drawers and
doors … the best materials, designs and
configurations are available on the Compartment Types
Specialist Rescues to fit the most • Transverse compartments
demanding requirements. • Under body storage compartments Air, electric and hydraulic reels Storage compartments for suits
• Rooftop storage compartments
Light towers, mounted on
Use this brochure as an overview of the • Wheel well air bottle compartments
cab or body
many features and options available on • Air bag, backboard and stokes
basket compartments Wheel chocks conveniently
your Specialist Rescue. Then connect and immediately accessible
• Ground ladder compartments
with a Seagrave dealer to explore and
specify each of the variables and
construction details.

The Specialist Rescues carry on the


Rooftop Access
Seagrave tradition of superior • Ladder Accessories
construction and high-performance design • Built-in steps • Absorbent storage hoppers
features. When you’ve got a special task • Fold-up steps Portable winch receivers in • Air compressors
ahead of you, respond with the confidence wheel well Roll-out trays for easy tool access Air cylinder storage • Air hose reels
of a Specialist. compartments • Awnings
• Cable reels
Shown here is a heavy-duty • Cascade air systems
Specialist Rescue
• Communication equipment
• Dry-erase boards
• Fill stations
Fold-up steps (where needed) • Interior ventilation
• Light towers
Highly Functional
Rooftop Walkways • Over pack drum storage
• Receiving tubes
Dedicated to quality since 1881 • Well-lit end to end
• Security equipment
• Diamond plated for
non-slip surface • Tool boards
• Provide access to topside • Water pumps
Stairs to rooftop compartments and Water-tight, rooftop compartments and Air cylinder storage in • Water tanks
equipment center walkway wheel wells — taking
• Winches
advantage of all available
Rooftop walkway with optional light tower space Side and rear awnings with manual or power operation

Vous aimerez peut-être aussi