Vous êtes sur la page 1sur 37

ABB

Technology and Solutions


Protection and Substation Automation

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Topic:
Energy Node
Substation /
Switchgear /
Busbar
Introduction
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Energy Node
r Clarification / Definition
r Switchgear Features
r Common Switchgear Configurations
r Special Switchgear Configurations
r Connections
r Busbar Protection
Objectives / Overview
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Clarification / Definition - Substation
The Substation includes every part in the energy node: Switchgear (of different
voltage levels), Transformers, Buildings etc. E.g. Substation Mettlen
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
4
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Clarification / Definition - Switchgear
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
5
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Clarification / Definition - Switchgear
380 kV Switchgear & Line
220 kV Switchgear & Line
380 / 220 kV Transformer
150 kV Switchgear & Line
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
6
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Clarification / Definition - Busbar
e.g. 380 kV
Busbar 1
Busbar 2
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
7
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
The main distinguishing feature of switchgears
is the Insulation Medium:
AIR: Air Insulated Switchgear (AIS)
GAS (SF6): Gas Insulated Switchgear (GIS)
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
8
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
The advantages of a GIS are:
q Less space required / Compact
q Low weight
q Higher reliability
q Personal Safety
q Low maintenance
q Long life
The disadvantage:
q Higher purchase cost
(for the switchgear!)
Switchgear Features
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
9
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
Location
Indoor Outdoor
no limitation no limitation Outdoor
no limitation
Usually
132 kV
Indoor
GIS AIS
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
0
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
Data: e.g. example ABB
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
1
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
AIS Layout example
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
2
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
GIS Layout example
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
3
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
GIS Cross Section example
Up to voltages of 170 kV (new
up to 245 kV), the 3 phases are
generally in a common
enclosure (tube), at higher
voltages the phases are
segregated.
The encapsulation consists of
non magnetic and corrosion
resistant aluminium or welted
aluminium sheets.
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
4
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Switchgear Features
GIS example
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
5
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Circuit Configurations for High- and Medium Voltage
switchgear installations
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
6
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Single Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
7
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Double Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
8
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Double Busbar in U connection
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
1
9
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Composite Double /
Bypass Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
0
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Double Busbar with draw- out
circuit breaker
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
1
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Two breaker method
with draw- out CB
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
2
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Double Busbar with
Bypass Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
3
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Common Switchgear Configurations
Triple Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
4
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Special Switchgear Configurations (mainly outside EU)
Double Busbar with
Shunt Disconnector
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
5
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Special Switchgear Configurations (mainly outside EU)
Two Breaker method
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
6
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Special Switchgear Configurations (mainly outside EU)
1 CB method
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
7
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Special Switchgear Configurations (mainly outside EU)
Cross- tie method
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
8
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Special Switchgear Configurations (mainly outside EU)
Ring Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
2
9
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Branch / Feeder
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
0
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Busbar Coupling Double Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
1
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Busbar Coupling Double Busbar with Transfer Bus
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
2
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Busbar Coupling Triple Busbar
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
3
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Busbar Coupling Triple Busbar with Transfer Bus
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
4
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Connections
Instrument Transformer
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
5
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Busbar Protection
The installed BBP must fit to all
q Features
q Configurations
q Connections
Depending on the Configuration and Position of the
switches more or less components in the Protection
Zone of the BBP:
q Voltage Transformer
q Circuit Breaker
q Disconnector / Earthing Switch
q Transfer Busbar
q Surge Arrester etc.
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
6
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W
Busbar Protection
. some components are located within the Zone of the
BBP, other within the Line or Transformer Protection
Zone
. details in separate lessons
ABB

A
B
B

S
w
i
t
z
e
r
l
a
n
d

L
t
d
.
-
3
7
C
H
P
1
3
3
_
E
_
N
o
d
e

/

2
0
0
7
0
9

/

R
W

Vous aimerez peut-être aussi