PRODUCT DESCRIPTION
TigerPROFILES Z-Purlins are the secondary structural members used to support the roof
sheeting / wall cladding. Besides being economical to use, they give an excellent
strength- to- weight ratio, thus giving tremendous cost savings. They are
characterized by: High strength to weight ratio; Economical; Can be used for large
spans upto 11.0m; Quick installation and being mostly Custom made.

Measurement (in mm)

Roofing

Usage

Material
Material Thickness
(Post Production)

Galvanized Iron (GI) Grade SQ-50 ASTM A653M

Galvanized Iron (GI): 1.50 to 3.50mm


Span: Upto 11.0 metres

Dimensions
Depth: 100 to 450mm
Coating/Finish

G90 (275 grams/m2 Zinc Coating)

Key Features

*Minimum Specified Yield Stress (fy) = 345 N/mm2


T: +971 6 533 8449
F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 2 of 27

General Properties

Section Properties

Section Weight
a
b
c
d mm t mm
Kg/m
mm mm mm

lx defl
cm4

sx(t)
cm4

Sx (b) Sxe(t)
cm3
cm3

Sxe(b)
Rx cm ly cm4 Sy cm3 Ry cm
cm3

Z 12215

2.92

122 1.50

55

50

17

88.500

14.800 14.230 13.099

13.922 4.864 29.920

4.610

2.828

Z 14215

3.21

142 1.50

55

50

20 128.900

18.480 17.830 17.203

17.600 5.585 33.650

5.010

2.854

Z 14218

3.85

142

1.8

55

50

20 153.300

21.990 21.210 21.990

21.210 5.571 39.900

5.960

2.842

Z 14220

4.29

142 2.00

55

50

20 169.300

24.290 23.430 24.290

23.430 5.561 43.990

6.580

2.834

Z 14225

5.36

142 2.50

55

50

20 208.600

29.920 28.860 29.920

28.860 5.537 53.910

8.090

2.815

Z 17215

3.45

172 1.50

55

50

15 194.000

22.950 22.190 20.040

21.490 6.617 27.580

4.330

2.495

Z 17218

4.14

172 1.80

55

50

15 231.000

27.320 26.420 25.690

26.080 6.602 32.680

5.140

2.483

Z 17220

4.60

172 2.00

55

50

15 255.300

30.200 29.200 28.820

28.920 6.592 36.010

5.670

2.476

Z 17225

5.75

172 2.50

55

50

15 315.000

37.250 36.020 37.250

36.020 6.567 44.080

6.970

2.457

Z 18215

3.57

182 1.50

55

50

16 223.700

24.980 24.190 22.110

23.490 6.965 28.740

4.460

2.497

Z 18218

4.28

182 1.80

55

50

16 266.400

29.750 28.810 29.690

28.490 6.950 34.070

5.300

2.485

Z 18220

4.76

182 2.00

55

50

16 294.500

32.890 31.850 31.740

31.620 6.939 37.550

5.840

2.478

Z 18225

5.95

182 2.50

55

50

16 363.500

40.600 39.300 40.600

39.300 6.914 45.960

7.180

2.459

Z 20215

3.92

202 1.50

60

55

16 301.700

30.320 29.440 26.290

28.410 7.721 35.860

5.160

2.662

Z 20218

4.7

202 1.80

60

55

16 359.600

36.130 35.080 32.500

34.200 7.705 42.540

6.130

2.650

Z 20220

5.23

202 2.00

60

55

16 397.700

39.960 38.800 37.490

38.250 7.695 46.910

6.770

2.643

Z 20225

6.53

202 2.50

60

55

16 491.400

49.380 47.940 48.050

47.670 7.670 57.510

8.330

2.624

Z 23215

4.53

232 1.50

70

65

17 462.700

40.400 39.380 31.970

37.540 8.900 55.220

6.890

3.075

Z 23218

5.44

232 1.80

70

65

17 551.900

48.190 46.980 41.400

45.210 8.884 65.610

8.200

3.063

Z 23220

6.04

232 2.00

70

65

17 610.800

53.340 51.990 45.880

50.050 8.874 72.420

9.060

3.056

Z 23225

7.55

232 2.50

70

65

17 755.900

66.010 64.340 62.070

63.450 8.849 89.020 11.170

3.037

Z 25215

4.76

252 1.50

70

65

16 558.900

44.900 43.820 34.060

41.650 9.563 53.410

6.710

2.956

Z 25218

5.71

252 1.80

70

65

16 666.800

53.580 52.290 46.120

50.240 9.547 63.440

7.990

2.945

Z 25220

6.34

252 2.00

70

65

16 738.100

59.310 57.870 50.940

55.570 9.537 70.020

8.830

2.937

Z 25225

7.93

252 2.50

70

65

16 913.900

73.430 71.660 68.630

70.470 9.511 86.060 10.880

2.918

Z 26215

5.18

262 1.50

80

72

20 672.800

52.300 50.450 38.150

47.850 10.069 81.490

8.890

3.504

Z 26218

6.22

262 1.80

80

72

20 803.200

62.430 60.230 51.100

57.530 10.054 96.930 10.590

3.493

Z 26220

6.91

262 2.00

80

72

20 889.300

69.130 66.680 58.870

64.050 10.044 107.070 11.710

3.485

Z 26225

8.63

262 2.50

80

72

20 1101.900

85.660 82.620 75.890

80.220 10.019 131.890 14.460

3.466

Z 30218

6.85

302 1.80

85

80

16 1159.100

77.550 75.990 54.030

71.170 11.483 106.240 11.250

3.477

Z 30220

7.61

302 2.00

85

80

16 1283.800

85.900 84.170 64.840

79.330 11.473 117.370 12.440

3.469

Z 30225

9.52

302 2.50

85

80

16 1592.200 106.530 104.380 87.610

98.900 11.447 144.640 15.370

3.450

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 3 of 27
Working Loads

Total
UDL KN

Allowable downward loads in Total UDL


Kn/m2
Kn

Section Weight
Ref
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

2000

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 3.50 M
Z 12215

2.92

6.02

1.72

1.43

1.15

0.96

0.86

6.16

4.52

7.53

Z 14215

3.21

8.05

2.30

1.92

1.53

1.28

1.15

8.96

5.88

9.63

Z 14218

3.85

9.97

2.85

2.38

1.90

1.58

1.43

10.68

7.00

11.45

Z 14220

4.29

11.06

3.16

2.63

2.11

1.76

1.58

11.80

7.77

12.53

Z 14225

5.36

13.65

3.90

3.25

2.60

2.17

1.95

14.53

10.01

15.40

Span 4.00 M

BUTT SYSTEM

Z 12215

2.92

5.36

1.34

1.12

0.89

0.74

0.67

4.72

3.56

5.92

Z 14215

3.21

7.04

1.76

1.47

1.17

0.98

0.88

6.88

4.68

7.61

Z 14218

3.85

8.80

2.20

1.83

1.47

1.22

1.10

8.20

5.80

9.04

Z 14220

4.29

9.64

2.41

2.01

1.61

1.34

1.21

9.00

6.44

9.92

Z 14225

5.36

11.88

2.97

2.48

1.98

1.65

1.49

11.08

7.92

12.24

Z17215

3.45

8.24

2.06

1.72

1.37

1.14

1.03

10.28

5.48

8.40

Z 17218

4.14

10.56

2.64

2.20

1.76

1.47

1.32

12.28

7.00

10.00

Z 17220

4.6

11.84

2.96

2.47

1.97

1.64

1.48

13.60

7.84

11.04

Z 17225

5.75

14.96

3.74

3.12

2.49

2.08

1.87

16.80

9.92

13.40

Z 14215

3.21

6.30

1.40

1.17

0.93

0.78

0.70

5.40

4.19

5.94

Z 14218

3.85

7.74

1.72

1.43

1.15

0.78

0.86

6.44

5.18

7.16

Z 14220

4.29

8.60

1.91

1.59

1.27

0.78

0.96

7.16

5.72

7.83

Z 14225

5.36

10.62

2.36

1.97

1.57

0.78

1.18

8.78

7.02

9.59

Z 17215

3.45

7.34

1.63

1.36

1.09

0.78

0.82

8.15

4.86

6.21

Z 17218

4.14

9.41

2.09

1.74

1.39

0.78

1.05

9.77

6.26

7.34

Z 17220

4.6

10.53

2.34

1.95

1.56

0.78

1.17

10.71

7.02

8.15

Z 17225

5.75

13.19

2.93

2.44

1.95

0.78

1.47

13.32

8.82

9.90

Z 18215

3.57

8.55

1.90

1.58

1.27

0.78

0.95

9.41

5.36

6.84

Z 18218

4.28

10.35

2.30

1.92

1.53

0.78

1.15

11.25

6.84

8.15

Z 18220

4.76

11.61

2.58

2.15

1.72

0.78

1.29

12.47

7.74

8.96

Z 18225

5.92

14.49

3.22

2.68

2.15

0.78

1.61

15.39

9.59

11.03

Z 20215

3.92

9.59

2.13

1.78

1.42

0.78

1.07

12.78

6.39

9.18

Z 20218

4.7

11.97

2.66

2.22

1.77

0.78

1.33

15.12

7.92

11.03

Z 20220

5.23

13.68

3.04

2.53

2.03

0.78

1.52

16.65

9.09

12.11

Z 20225

6.53

17.51

3.89

3.24

2.59

0.78

1.95

20.75

11.61

14.85

Span 4.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/2 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 4 of 27
Working Loads

Total
UDL KN

Allowable downward loads


in Kn/m2

Section Weight
Ref
Kg/m

[Purlin Centres in
mms]
1000 1200

1500

1800

2000

Total UDL
Kn

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 5.00 M

BUTT SYSTEM

Z 17215

3.45

6.60

1.32

1.10

0.88

0.73

0.66

6.60

4.35

4.50

7.75

Z 17218

4.14

8.45

1.69

1.41

1.13

0.94

0.85

7.85

5.65

5.65

9.50

Z 17220

4.6

9.50

1.90

1.58

1.27

1.06

0.95

8.7

6.35

6.35

10.45

Z 17225

5.75

11.85

2.37

1.98

1.58

1.32

1.19

10.75

7.95

7.95

12.85

Z 18215

3.57

7.30

1.46

1.22

0.97

0.81

0.73

7.65

4.85

5.00

8.65

Z 18218
Z 18220

4.28
4.76

9.35
10.50

1.87
2.10

1.56
1.75

1.25
1.40

1.04
1.17

0.94
1.05

9.05
10.10

6.20
6.95

6.20
6.95

10.35
11.40

Z 18225

5.92

12.95

2.59

2.16

1.73

1.44

1.30

12.45

8.60

8.65

14.10

Z 20215

3.92

8.60

1.72

1.43

1.15

0.96

0.86

10.35

5.75

7.00

10.25

Z 20218
Z 20220

4.7
5.23

10.75
12.35

2.15
2.47

1.79
2.06

1.43
1.65

1.19
1.37

1.08
1.24

12.35
13.55

7.10
8.25

8.25
9.05

12.85
14.35

Z 20225

6.53

15.80

3.16

2.63

2.11

1.76

1.58

16.8

10.55

11.2

18.05

Z 23215

4.53

10.45

2.09

1.74

1.39

1.16

1.05

15.8

6.95

10.65

13.30

Z 23218

5.44

13.40

2.68

2.23

1.79

1.49

1.34

18.85

8.90

13.45

16.80

Z 23220

6.04

15.05

3.01

2.51

2.01

1.67

1.51

20.9

10.00

15.15

19.40

Z 23225

7.55

20.30

4.06

3.38

2.71

2.26

2.03

25.75

13.50

19.00

25.00

Span 5.50 M
Z 18215

3.57

6.60

1.20

1.00

0.80

0.67

0.60

6.27

4.40

4.40

7.32

Z 18218

4.28

8.53

1.55

1.29

1.03

0.86

0.78

7.54

5.67

5.67

8.69

Z 18220

4.76

9.46

1.72

1.43

1.15

0.96

0.86

8.58

6.27

6.27

9.63

Z 18225

5.92

11.83

2.15

1.79

1.43

1.19

1.08

10.23

7.81

7.81

11.83

Z 20215

3.92

7.81

1.42

1.18

0.95

0.79

0.71

8.47

5.23

5.23

9.02

Z 20218

4.70

9.79

1.78

1.48

1.19

0.99

0.89

10.18

6.44

6.44

11.06

Z 20220

5.23

11.22

2.04

1.70

1.36

1.13

1.02

11.22

7.48

7.48

12.43

Z 20225

6.53

14.36

2.61

2.18

1.74

1.45

1.31

13.92

9.57

9.57

15.18

Z 23215

4.53

9.52

1.73

1.44

1.15

0.96

0.87

13.04

6.33

8.75

11.66

Z 23218

5.44

12.16

2.21

1.84

1.47

1.23

1.11

15.57

8.09

10.78

14.74

Z 23220

6.04

13.81

2.51

2.09

1.67

1.39

1.26

17.22

9.19

12.16

17.11

Z 23225

7.55

18.37

3.34

2.78

2.23

1.86

1.67

21.34

12.21

15.07

21.84

Z 25215

4.76

10.12

1.84

1.53

1.23

1.02

0.92

15.79

6.71

9.3

12.38

Z 25218

5.71

13.42

2.44

2.03

1.63

1.36

1.22

18.87

8.91

11.28

16.12

Z 25220

6.34

15.24

2.77

2.31

1.85

1.54

1.39

20.85

10.12

12.82

18.54

Z 25225

7.93

20.57

3.74

3.12

2.49

2.08

1.87

25.69

13.64

17.05

23.65

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 5 of 27
Working Loads

Total
UDL KN

Allowable downward loads


in Kn/m2

Section Weight
Ref
Kg/m

[Purlin Centres in
mms]
1000 1200

1500

1800

2000

Total UDL
Kn

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 6.00 M

BUTT SYSTEM

Z 18215

3.57

6.06

1.01

0.84

0.67

0.56

0.51

5.28

4.02

4.02

6.06

Z 18218

4.28

7.74

1.29

1.08

0.86

0.72

0.65

6.30

5.16

5.16

7.26

Z 18220

4.76

8.70

1.45

1.21

0.97

0.81

0.73

7.02

5.76

5.76

7.98

Z 18225

5.92

10.86

1.81

1.51

1.21

1.01

0.91

8.58

7.2

7.2

9.84

Z 20215

3.92

7.20

1.20

1.00

0.80

0.67

0.60

7.14

4.74

4.74

7.74

Z 20218
Z 20220
Z 20225

4.70
5.23
6.53

8.94
10.26
13.14

1.49
1.71
2.19

1.24
1.43
1.83

0.99
1.14
1.46

0.83
0.95
1.22

0.75
0.86
1.10

8.52
9.42
11.64

5.94
6.84
8.76

5.94
6.84
8.76

9.54
10.5
12.84

Z 23215

4.53

8.70

1.45

1.21

0.97

0.81

0.73

10.98

5.82

6.96

10.38

Z 23218

5.44

11.16

1.86

1.55

1.24

1.03

0.93

13.14

7.44

8.52

13.02

Z 23220

6.04

12.66

2.11

1.76

1.41

1.17

1.06

14.52

8.34

9.48

15.12

Z 23225

7.55

16.86

2.81

2.34

1.87

1.56

1.41

17.94

11.22

11.52

19.32

Z 25215

4.76

9.30

1.55

1.29

1.03

0.86

0.78

13.26

6.12

7.38

10.92

Z 25218

5.71

12.24

2.04

1.70

1.36

1.13

1.02

15.90

8.16

8.94

14.28

Z 25220

6.34

14.04

2.34

1.95

1.56

1.30

1.17

17.52

9.24

9.84

16.5

Z 25225

7.93

18.72

3.12

2.60

2.08

1.73

1.56

21.72

12.48

12.48

20.76

Span 6.50 M
Z 20215

3.92

6.63

1.02

0.85

0.68

0.57

0.51

5.53

4.42

4.42

6.57

Z 20218

4.70

8.26

1.27

1.06

0.85

0.71

0.64

7.28

5.46

5.46

8.00

Z 20220

5.23

9.49

1.46

1.22

0.97

0.81

0.73

8.00

6.31

6.31

8.84

Z 20225

6.53

12.16

1.87 1056

1.25

1.04

0.94

9.95

8.06

8.06

10.86

Z 23215

4.53

8.06

1.24

1.03

0.83

0.69

0.62

9.36

5.33

5.66

9.36

Z 23218

5.44

10.34

1.59

1.33

1.06

0.88

0.80

11.12

6.83

6.83

11.57

Z 23220

6.04

11.57

1.78

1.48

1.19

0.99

0.89

12.29

7.74

7.74

13.07

Z 23225

7.55

15.6

2.40

2.00

1.60

1.33

1.20

15.28

10.27

10.27

16.84

Z 25215

4.76

8.58

1.32

1.10

0.88

0.73

0.66

11.25

5.72

5.92

9.49

Z 25218

5.71

11.31

1.74

1.45

1.16

0.97

0.87

13.46

7.54

7.54

12.55

Z 25220

6.34

12.87

1.98

1.65

1.32

1.10

0.99

14.95

8.58

8.58

14.3

Z 25225

7.93

17.36

2.67

2.23

1.78

1.48

1.34

18.46

11.57

11.57

18.07

Z 26215

5.18

9.56

1.47

1.23

0.98

0.82

0.74

13.65

6.37

8.71

11.77

Z 26218

6.22

12.74

1.96

1.63

1.31

1.09

0.98

10.79

8.45

10.79

15.08

Z 26220

6.91

14.76

2.27

1.89

1.51

1.26

1.14

11.96

9.82

12.09

17.49

Z 26225

8.63

19.18

2.95

2.46

1.97

1.64

1.48

22.30

12.74

14.95

23.14

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 6 of 27
Working Loads

Total
UDL KN

Allowable downward loads


in Kn/m2

Section Weight
Ref
Kg/m

[Purlin Centres in
mms]
1000 1200

1500

1800

2000

Total UDL
Kn

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 7.00 M

BUTT SYSTEM

Z 20215

3.92

6.16

0.88

0.73

1.59

0.49

0.44

5.25

4.06

4.06

5.60

Z 20218

4.70

7.63

1.09

0.91

0.73

0.61

0.55

6.23

5.11

5.11

6.72

Z 20220

5.23

8.82

1.26

1.05

0.84

0.70

0.63

6.93

5.88

5.88

7.42

Z 20225

6.53

11.27

1.61

1.34

1.07

0.89

0.81

8.61

7.49

7.49

9.10

Z 23215

4.53

7.49

1.07

0.89

0.71

0.59

0.54

8.05

4.97

4.97

7.98

Z 23218

5.44

9.59

1.37

1.14

0.91

0.76

0.69

9.59

6.37

6.37

10.22

Z 23220

6.04

10.78

1.54

1.28

1.03

0.86

0.77

10.64

7.14

7.14

11.48

Z 23225

7.55

14.35

2.05

1.71

1.37

1.14

1.03

13.16

9.66

9.66

14.84

Z 25215

4.76

7.98

1.14

0.95

0.76

0.63

0.57

9.73

5.32

5.32

8.54

Z 25218

5.71

10.50

1.50

1.25

1.00

0.83

0.75

11.62

7.00

7.00

11.13

Z 25220
Z 25225
Z 26215

6.34
7.93
5.18

11.90
16.10
8.89

1.70
2.30
1.27

1.42
1.92
1.06

1.13
1.53
0.85

0.94
1.28
0.71

0.85
1.15
0.64

12.88
15.89
11.69

7.98
10.71
5.95

7.98
10.71
5.95

12.46
15.96
10.57

Z 26218

6.22

11.83

1.69

1.41

1.13

0.94

0.85

14.07

7.84

8.82

13.72

Z 26220

6.91

13.72

1.96

1.63

1.31

1.09

0.98

15.54

9.10

9.66

15.68

Z 26225

8.63

17.92

2.56

2.13

1.71

1.42

1.28

19.25

11.90

11.90

20.51

Z 20215

3.92

5.78

0.77

0.64

0.51

0.43

0.39

4.58

3.83

3.83

4.65

Z 20218

4.70

7.13

0.95

0.79

0.63

0.53

0.48

5.48

4.73

4.73

5.48

Z 20220

5.23

8.25

1.10

0.92

0.73

0.61

0.55

6.00

5.48

5.48

6.08

Z 20225

6.53

10.58

1.41

1.18

0.94

0.78

0.71

7.43

6.98

6.98

11.03

Z 23215

4.53

6.98

0.93

0.78

0.62

0.52

0.47

7.05

4.65

4.65

8.40

Z 23218

5.44

8.93

1.19

0.99

0.79

0.66

0.60

8.40

5.93

5.93

10.73

Z 23220

6.04

10.13

1.35

1.13

0.90

0.75

0.68

9.23

6.68

6.68

12.30

Z 23225

7.55

13.50

1.80

1.50

1.20

1.00

0.90

11.40

9.00

9.00

15.75

Z 25215

4.76

7.43

0.99

0.83

0.66

0.55

0.50

8.55

4.95

4.95

9.00

Z 25218

5.71

9.83

1.31

1.09

0.87

0.73

0.66

10.13

6.53

6.53

11.85

Z 25220

6.34

11.18

1.49

1.24

0.99

0.83

0.75

11.18

7.43

7.43

13.50

Z 25225

7.93

15.08

2.01

1.68

1.34

1.12

1.01

13.80

9.98

9.98

17.18

Z 26215

5.18

8.33

1.11

0.93

0.74

0.62

0.56

10.28

5.55

5.93

10.43

Z 26218

6.22

11.03

1.47

1.23

0.98

0.82

0.74

12.23

7.35

7.35

14.10

Z 26220

6.91

12.75

1.70

1.42

1.13

0.94

0.85

13.58

8.48

8.48

15.98

Z 26225

8.63

16.73

2.23

1.86

1.49

1.24

1.12

16.73

11.10

11.10

21.30

Span 7.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 7 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads


in Kn/m2

Weight
Kg/m

[Purlin Centres in
mms]
1000 1200

1500

1800

2000

Total UDL
Kn

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 8.00 M

BUTT SYSTEM

Z 20215

4.53

6.56

0.82

0.68

0.55

0.46

0.41

6.16

4.32

4.32

6.24

Z 20218

5.44

8.40

1.05

0.88

0.70

0.58

0.53

7.36

5.60

5.60

7.76

Z 20220

6.04

9.44

1.18

0.98

0.79

0.66

0.59

8.08

6.32

6.32

8.80

Z 20225

7.55

12.64

1.58

1.32

1.05

0.88

0.79

10.08

8.40

8.40

10.88

Z 23215

4.76

6.96

0.87

0.73

0.58

0.48

0.44

7.44

4.64

4.64

6.64

Z 23218

5.71

9.20

1.15

0.96

0.77

0.64

0.58

8.88

6.08

6.08

8.16

Z 23220

6.34

10.48

1.31

1.09

0.87

0.73

0.66

9.84

6.96

6.96

9.12

Z 23225

7.93

14.08

1.76

1.47

1.17

0.98

0.88

12.24

9.36

9.36

11.52

Z 25215

5.18

7.76

0.97

0.81

0.65

0.54

0.49

9.04

5.20

5.20

8.64

Z 25218

6.22

10.32

1.29

1.08

0.86

0.72

0.65

10.72

6.88

6.88

11.12

Z 25220

6.91

12.00

1.50

1.25

1.00

0.83

0.75

11.84

7.92

7.92

12.72

Z 25225

8.63

15.60

1.95

1.63

1.30

1.08

0.98

14.72

10.4

10.4

16.24

Z 26215

6.85

11.12

1.39

1.16

0.93

0.77

0.7

15.44

7.44

7.44

12.56

Z 26218

7.61

13.36

1.67

1.39

1.11

0.93

0.84

17.12

8.88

8.88

14.32

Z 26220

9.52

18.00

2.25

1.88

1.50

1.25

1.13

21.20

12.00

12.00

19.36

Z 23215

4.53

6.12

0.72

0.6

0.48

0.4

0.36

5.44

4.08

4.08

5.44

Z 23218

5.44

5.27

0.62

0.52

0.41

0.34

0.31

6.55

7.91

7.91

10.03

Z 23220

6.04

8.93

1.05

0.88

0.7

0.58

0.53

7.23

5.87

5.87

7.40

Z 23225

7.55

11.90

1.40

1.17

0.93

0.78

0.7

8.93

7.91

7.91

9.18

Z 25215

4.76

6.55

0.77

0.64

0.51

0.43

0.39

6.63

4.34

4.34

5.78

Z 25218

5.71

8.67

1.02

0.85

0.68

0.57

0.51

7.91

5.78

5.78

6.97

Z 25220

6.34

9.86

1.16

0.97

0.77

0.64

0.58

8.76

6.55

6.55

7.82

Z 25225

7.93

13.26

1.56

1.30

1.04

0.87

0.78

10.8

8.84

8.84

9.61

Z 26215

5.18

7.31

0.86

0.72

0.57

0.48

0.43

7.91

4.85

4.85

7.82

Z 26218

6.22

9.78

1.15

0.96

0.77

0.64

0.58

9.44

6.46

6.46

9.95

Z 26220

6.91

11.22

1.32

1.10

0.88

0.73

0.66

10.46

7.48

7.48

11.14

Z 26225

8.63

14.79

1.74

1.45

1.16

0.97

0.87

13.09

9.78

9.78

14.37

Z 30218

6.85

10.54

1.24

1.03

0.83

0.69

0.62

13.69

6.97

6.97

11.39

Z 30220

7.61

12.58

1.48

1.23

0.99

0.82

0.74

15.13

8.42

8.42

12.92

Z 30225

9.52

17.00

2.00

1.67

1.33

1.11

1.00

18.87

11.31

11.31

17.34

Span 8.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 8 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000 1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 9.00 M

BUTT SYSTEM

Z 23215

4.53

5.76

0.64

0.53

0.43

0.36

0.32

4.86

3.87

3.87

4.68

6.39

Z 23218

5.44

7.47

0.83

0.69

0.55

0.46

0.42

5.85

4.95

4.95

5.67

8.10

Z 23220

6.04

8.37

0.93

0.78

0.62

0.52

0.47

6.39

5.58

5.58

6.30

9.27

Z 23225

7.55

11.25

1.25

1.04

0.83

0.69

0.63

7.92

7.47

7.47

7.74

11.88

Z 25215

4.76

6.21

0.69

0.58

0.46

0.38

0.35

5.94

4.14

4.14

4.86

6.75

Z 25218

5.71

8.19

0.91

0.76

0.61

0.51

0.46

7.02

5.40

5.40

5.94

8.82

Z 25220

6.34

9.36

1.04

0.87

0.69

0.58

0.52

7.74

6.21

6.21

6.57

9.99

Z 25225

7.93

12.51

1.39

1.16

0.93

0.77

0.7

9.63

8.28

8.28

8.28

12.69

Z 26215

5.18

6.93

0.77

0.64

0.51

0.43

0.39

7.02

4.59

4.59

7.02

8.37

Z 26218

6.22

9.18

1.02

0.85

0.68

0.57

0.51

8.46

6.12

6.12

8.82

10.71

Z 26220

6.91

10.62

1.18

0.98

0.79

0.66

0.59

9.36

7.02

7.02

9.90

12.51

Z 26225

8.63

13.95

1.55

1.29

1.03

0.86

0.78

11.61

9.27

9.27

12.51

16.20

Z 30218

6.85

9.90

1.10

0.92

0.73

0.61

0.55

12.24

6.57

6.57

10.26

11.97

Z 30220

7.61

11.88

1.32

1.10

0.88

0.73

0.66

13.50

7.92

7.92

11.43

14.4

Z 30225

9.52

16.02

1.78

1.48

1.19

0.99

0.89

16.83

10.71

10.71

15.30

19.08

Span 9.50 M
Z 25215

4.76

5.89

0.62

0.52

0.41

0.34

0.31

5.32

3.90

3.90

4.18

6.27

Z 25218

5.71

7.70

0.81

0.68

0.54

0.45

0.41

6.27

5.13

5.13

5.13

7.98

Z 25220

6.34

8.84

0.93

0.78

0.62

0.52

0.47

7.03

5.89

5.89

5.89

8.93

Z 25225

7.93

11.88

1.25

1.04

0.83

0.69

0.63

8.65

7.89

7.89

7.89

11.4

Z 26215

5.18

6.56

0.69

0.58

0.46

0.38

0.35

6.37

4.37

4.37

6.18

7.60

Z 26218

6.22

8.74

0.92

0.77

0.61

0.51

0.46

7.60

5.80

5.80

7.70

9.98

Z 26220

6.91

10.07

1.06

0.88

0.71

0.59

0.53

8.36

6.65

6.65

8.74

11.40

Z 26225

8.63

13.21

1.39

1.16

0.93

0.77

0.70

10.36

8.74

8.74

10.74

14.82

Z 30218

6.85

9.41

0.99

0.83

0.66

0.55

0.50

10.93

6.27

6.27

8.93

11.21

Z 30220

7.61

11.31

1.19

0.99

0.79

0.66

0.60

12.16

7.51

7.51

10.26

13.40

Z 30225

9.52

15.2

1.6

1.33

1.07

0.89

0.80

15.01

10.07

10.07

13.40

17.67

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 9 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads in Total UDL


Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

2000

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 3.50 M
Z 12215

2.92

9.63

2.75

2.29

1.83

1.53

1.38

11.83

9.41

10.43

Z 14215

3.21

12.67

3.62

3.02

2.41

2.01

1.81

17.23

12.18

13.51

Z 14218

3.85

15.61

4.46

3.72

2.97

2.48

2.23

20.49

14.57

16.17

Z 14220

4.29

17.26

4.93

4.11

3.29

2.74

2.47

22.63

16.13

17.88

Z 14225

5.36

21.28

6.08

5.07

4.05

3.38

3.04

27.88

19.85

21.63

Z 12215

2.92

8.44

2.11

1.76

1.41

1.17

1.06

9.06

8.24

8.24

Z 14215

3.21

11.08

2.77

2.31

1.85

1.54

1.39

13.19

1068

1068

Z 14218

3.85

13.68

3.42

2.85

2.28

1.90

1.71

15.69

12.72

12.72

Z 14220

4.29

15.08

3.77

3.14

2.51

2.09

1.89

17.33

14.10

14.10

Z 14225

5.36

18.48

4.62

3.85

3.08

2.57

2.31

21.35

17.36

17.36

Z 17215

3.45

12.92

3.23

2.69

2.15

1.79

1.62

19.86

12.45

12.45

Z 17218

4.14

16.56

4.14

3.45

2.76

2.3

2.07

23.64

15.45

15.45

Z 17220

4.60

18.6

4.65

3.88

3.1

2.58

2.33

26.13

17.58

17.58

Z 17225

5.75

23.24

5.81

4.84

3.87

3.23

2.91

32.24

21.67

21.67

Z 14215

3.21

9.86

2.19

1.83

1.46

0.78

1.10

10.42

9.48

9.48

Z 14218

3.85

12.15

2.70

2.25

1.80

0.78

1.35

12.4

8.52

8.52

Z 14220

4.29

13.41

2.98

2.48

1.99

0.78

1.49

13.69

12.54

12.54

Z 14225

5.36

16.52

3.67

3.06

2.45

0.78

1.84

16.87

15.45

15.45

Z 17215

3.45

11.48

2.55

2.13

1.70

0.78

1.28

15.69

11.08

11.08

Z 17218

4.14

14.72

3.27

2.73

2.18

0.78

1.64

18.68

13.75

13.75

Z 17220

4.60

16.52

3.67

3.06

2.45

0.78

1.84

20.64

15.62

15.62

Z 17225

5.75

20.61

4.58

3.82

3.05

0.78

2.29

25.47

19.28

19.28

Z 18215

3.57

12.65

2.81

2.34

1.87

0.78

1.41

18.09

12.29

12.29

Z 18218

4.28

16.16

3.59

2.99

2.39

0.78

1.80

21.54

15.26

15.26

Z 18220

4.76

18.14

4.03

3.36

2.69

0.78

2.02

23.81

17.03

17.03

Z 18225

5.92

22.55

5.01

4.18

3.34

0.78

2.51

29.4

21.04

21.04

Z 20215

3.92

15.08

3.35

2.79

2.23

0.78

1.68

24.4

14.01

14.01

Z 20218

4.70

18.63

4.14

3.45

2.76

0.78

2.07

29.08

17.85

17.85

Z 20220

5.23

21.47

4.77

3.98

3.18

0.78

2.39

32.16

20.18

20.18

Z 20225

6.53

27.32

6.07

5.06

4.05

0.78

3.04

39.74

25.62

25.62

Span 4.00 M

SLEEVE SYSTEM

Span 4.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3%

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 10 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 5.00 M

BUTT SYSTEM

Z 17215

3.45

10.35

2.07

1.73

1.38

1.15

1.04

12.71

9.99

9.99

Z 17218

4.14

13.25

2.65

2.21

1.77

1.47

1.33

15.13

12.36

12.36

Z 17220

4.60

14.85

2.97

2.48

1.98

1.65

1.49

16.72

14.06

14.06

Z 17225

5.75

18.6

3.72

3.10

2.48

2.07

1.86

20.63

17.35

17.35

Z 18215

3.57

11.4

2.28

1.90

1.52

1.27

1.14

14.65

11.07

11.07

Z 18218
Z 18220
Z 18225

4.28
4.76
5.92

14.55
16.3
20.3

2.91
3.26
4.06

2.43
2.72
3.38

1.94
2.17
2.71

1.62
1.81
2.26

1.46
1.63
2.03

17.45
19.29
23.81

13.71
15.32
18.93

13.71
15.32
18.93

Z 20215

3.92

13.55

2.71

2.26

1.81

1.51

1.36

19.76

12.60

12.60

Z 20218
Z 20220

4.70
5.23

16.75
19.3

3.35
3.86

2.79
3.22

2.23
2.57

1.86
2.14

1.68
1.93

23.55
26.05

16.06
18.02

16.06
18.02

Z 20225

6.53

24.6

4.92

4.10

3.28

2.73

2.46

32.19

23.06

23.06

Z 23215

4.53

16.5

3.3

2.75

2.20

1.83

1.65

30.31

15.19

15.19

Z 23218

5.44

21.35

4.27

3.56

2.85

2.37

2.14

36.15

19.61

19.61

Z 23220

6.04

23.65

4.73

3.94

3.15

2.63

2.37

40.01

22.59

22.59

Z 23225

7.55

32.05

6.41

5.34

4.27

3.56 3.21
Span 5.50 M

49.51

29.52

29.52

Z 18215

3.57

10.34

1.88

1.57

1.25

1.04

0.94

12.11

10.05

10.05

10.05

Z 18218

4.28

13.26

2.41

2.01

1.61

1.34

1.21

14.42

12.47

12.47

12.47

Z 18220

4.76

14.80

2.69

2.24

1.79

1.49

1.35

15.94

13.93

13.93

13.93

Z 18225

5.92

18.43

3.35

2.79

2.23

1.86

1.68

19.68

17.20

17.20

17.20

Z 20215

3.92

12.32

2.24

1.87

1.49

1.24

1.12

16.33

11.45

11.45

12.88

Z 20218

4.70

15.24

2.77

2.31

1.85

1.54

1.39

19.47

14.60

14.60

15.78

Z 20220

5.23

17.55

3.19

2.66

2.13

1.77

1.60

21.53

16.42

16.42

17.48

Z 20225

6.53

22.33

4.06

3.38

2.71

2.26

2.03

26.6

21.02

21.02

21.54

Z 23215

4.53

14.96

2.72

2.27

1.81

1.51

1.36

25.05

13.80

13.80

17.58

Z 23218

5.44

19.42

3.53

2.94

2.35

1.96

1.77

29.88

17.83

17.83

21.56

Z 23220

6.04

21.51

3.91

3.26

2.61

2.17

1.96

33.06

20.53

20.53

25.29

Z 23225

7.55

29.10

5.29

4.41

3.53

2.94

2.65

40.92

26.85

26.85

32.35

Z 25215

4.76

15.95

2.90

2.42

1.93

1.61

1.45

30.25

14.72

14.72

18.51

Z 25218

5.71

21.62

3.93

3.28

2.62

2.18

1.97

36.10

19.38

19.38

24.08

Z 25220

6.34

23.87

4.34

3.62

2.89

2.41

2.17

39.96

22.75

22.75

27.57

Z 25225

7.93

32.18

5.85

4.88

3.90

3.25

2.93

49.47

29.82

29.82

35.04

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 11 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

2000

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods


Span/180

Span 6.00 M

BUTT SYSTEM

Z 18215

3.57

9.48

1.58

1.32

1.05

0.88

0.79

10.17

9.22

9.22

9.22

Z 18218

4.28

12.12

2.02

1.68

1.35

1.12

1.01

12.12

11.41

11.41

11.41

Z 18220

4.76

13.56

2.26

1.88

1.51

1.26

1.13

13.40

12.77

12.77

12.77

Z 18225

5.92

16.86

2.81

2.34

1.87

1.56

1.41

16.53

15.77

15.77

15.77

Z 20215

3.92

11.28

1.88

1.57

1.25

1.04

0.94

13.72

10.51

10.51

10.80

Z 20218
Z 20220
Z 20225

4.70
5.23
6.53

13.98
16.14
20.46

2.33
2.69
3.41

1.94
2.24
2.84

1.55
1.79
2.27

1.29
1.49
1.89

1.17
1.35
1.71

16.35
18.09
22.35

13.39
15.02
19.21

13.39
15.02
19.21

13.39
15.02
19.21

Z 23215

4.53

13.74

2.29

1.91

1.53

1.27

1.15

21.04

12.66

12.66

15.07

Z 23218
Z 23220

5.44
6.04

17.76
19.74

2.96
3.29

2.47
2.74

1.97
2.19

1.64
1.83

1.48
1.65

25.10
27.78

16.35
18.81

16.35
18.81

19.26
21.75

Z 23225

7.55

26.64

4.44

3.7

2.96

2.47

2.22

34.38

24.60

24.60

28.09

Z 25215

4.76

14.64

2.44

2.03

1.63

1.36

1.22

25.42

13.50

13.50

15.82

Z 25218

5.71

19.80

3.30

2.75

2.2

1.83

1.65

30.33

17.76

17.76

20.9

Z 25220

6.34

21.90

3.65

3.04

2.43

2.03

1.83

33.57

20.85

20.85

23.58

Z 25225

7.93

29.52

4.92

4.1

3.28

2.73
2.46
Span 6.50 M

41.57

27.33

27.33

30.23

Z 20215

3.92

10.40

1.60

1.33

1.07

0.89

0.80

11.69

9.70

9.70

9.70

Z 20218

4.70

12.87

1.98

1.65

1.32

1.10

0.99

13.94

12.35

12.35

12.35

Z 20220

5.23

14.82

2.28

1.9

1.52

1.27

1.14

15.41

13.87

13.87

13.87

Z 20225

6.53

18.92

2.91

2.43

1.94

1.62

1.46

19.05

17.74

17.74

17.74

Z 23215

4.53

12.68

1.95

1.63

1.30

1.08

0.98

17.93

11.67

11.67

13.12

Z 23218

5.44

16.45

2.53

2.11

1.69

1.41

1.27

21.39

15.09

15.09

16.71

Z 23220

6.04

18.20

2.80

2.33

1.87

1.56

1.40

23.67

17.36

17.36

18.71

Z 23225

7.55

24.64

3.79

3.16

2.53

2.11

1.90

29.30

22.74

22.74

22.74

Z 25215

4.76

13.52

2.08

1.73

1.39

1.16

1.04

21.66

12.46

12.46

14.17

Z 25218

5.71

18.27

2.81

2.34

1.87

1.56

1.41

25.84

16.40

16.40

18.02

Z 25220

6.34

20.22

3.11

2.59

2.07

1.73

1.56

28.61

19.25

19.25

20.13

Z 25225

7.93

27.24

4.19

3.49

2.79

2.33

2.10

35.42

25.23

25.23

25.79

Z 26215

5.18

15.15

2.33

1.94

1.55

1.29

1.17

26.08

13.95

13.95

17.30

Z 26218

6.22

20.28

3.12

2.60

2.08

1.73

1.56

31.13

18.47

18.47

22.33

Z 26220

6.91

23.34

3.59

2.99

2.39

1.99

1.80

34.47

21.48

21.48

25.82

Z 26225

8.63

30.10

4.63

3.86

3.09

2.57

2.32

42.71

28.94

28.94

33.42

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 12 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 7.00 M

BUTT SYSTEM

Z 20215

3.92

9.66

1.38

1.15

0.92

0.77

0.69

10.08

9.00

9.00

9.00

Z 20218

4.70

11.97

1.71

1.43

1.14

0.95

0.86

12.02

11.47

11.47

11.47

Z 20220

5.23

13.79

1.97

1.64

1.31

1.09

0.99

13.29

12.90

12.90

12.90

Z 20225

6.53

17.57

2.51

2.09

1.67

1.39

1.26

16.42

16.47

16.47

16.47

Z 23215

4.53

11.76

1.68

1.4

1.12

0.93

0.84

15.46

10.85

10.85

11.41

Z 23218
Z 23220
Z 23225

5.44
6.04
7.55

15.19
16.87
22.82

2.17
2.41
3.26

1.81
2.01
2.72

1.45
1.61
2.17

1.21
1.34
1.81

1.09
1.21
1.63

18.44
20.41
25.26

14.00
16.14
21.10

14.00
16.14
21.10

14.25
16.14
21.10

Z 25215

4.76

12.53

1.79

1.49

1.19

0.99

0.90

18.68

11.57

11.57

12.24

Z 25218
Z 25220

5.71
6.34

16.94
18.76

2.42
2.68

2.02
2.23

1.61
1.79

1.34
1.49

1.21
1.34

22.28
24.67

15.22
17.87

15.22
17.87

15.22
17.87

Z 25225

7.93

25.27

3.61

3.01

2.41

2.01

1.81

30.54

23.43

23.43

23.43

Z 26215

5.18

14.00

2.00

1.67

1.33

1.11

1.00

22.48

12.95

12.95

15.43

Z 26218

6.22

18.83

2.69

2.24

1.79

1.49

1.35

26.84

17.15

17.15

19.78

Z 26220

6.91

21.7

3.10

2.58

2.07

1.72

1.55

29.72

19.94

19.94

22.87

Z 26225

8.63

28.00

4.00

3.33

2.67

2.22 2.00
Span 7.50 M

36.83

26.87

26.87

31.02

Z 20215

3.92

9.00

1.20

1.00

0.80

0.67

0.60

8.78

8.40

8.40

8.40

Z 20218

4.70

11.18

1.49

1.24

0.99

0.83

0.75

1.47

10.71

10.71

10.71

Z 20220

5.23

12.9

1.72

1.43

1.15

0.96

0.86

11.58

12.00

12.00

12.00

Z 20225

6.53

16.35

2.18

1.82

1.45

1.21

1.09

14.3

15.39

15.39

15.39

Z 23215

4.53

10.95

1.46

1.22

0.97

0.81

0.73

13.47

10.13

10.13

10.13

Z 23218

5.44

14.25

1.9

1.58

1.27

1.06

0.95

16.06

13.06

13.06

13.06

Z 23220

6.04

15.75

2.10

1.75

1.40

1.17

1.05

17.78

15.04

15.04

15.04

Z 23225

7.55

21.3

2.84

2.37

1.89

1.58

1.42

22.00

19.70

19.70

19.70

Z 25215

4.76

11.70

1.56

1.3

1.04

0.87

0.78

16.27

10.82

10.82

10.82

Z 25218

5.71

15.83

2.11

1.76

1.41

1.17

1.06

19.41

14.21

14.21

14.21

Z 25220

6.34

17.48

2.33

1.94

1.55

1.29

1.17

21.49

16.68

16.68

16.68

Z 25225

7.93

23.63

3.15

2.63

2.10

1.75

1.58

26.60

21.86

21.86

21.86

Z 26215

5.18

13.13

1.75

1.46

1.17

0.97

0.88

19.59

12.09

12.09

13.77

Z 26218

6.22

17.55

2.34

1.95

1.56

1.30

1.17

23.38

17.15

17.15

19.78

Z 26220

6.91

20.25

2.70

2.25

1.80

1.50

1.35

25.89

18.61

18.61

19.90

Z 26225

8.63

26.10

3.48

2.90

2.32

1.93

1.74

32.08

25.11

25.11

25.51

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3%

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 13 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 8.00 M

BUTT SYSTEM

Z 23215

4.53

10.32

1.29

1.08

0.86

0.72

0.65

11.84

9.48

9.48

9.48

Z 23218

5.44

13.36

1.67

1.39

1.11

0.93

0.84

14.12

12.25

12.25

12.25

Z 23220

6.04

14.8

1.85

1.54

1.23

1.03

0.93

15.63

14.12

14.12

14.12

Z 23225

7.55

20.00

2.50

2.08

1.67

1.39

1.25

19.34

18.46

18.46

18.46

Z 25215

4.76

10.96

1.37

1.14

0.91

0.76

0.69

14.3

10.12

10.12

10.12

Z 25218
Z 25220
Z 25225

5.71
6.34
7.93

14.88
16.4
22.08

1.86
2.05
2.76

1.55
1.71
2.3

1.24
1.37
1.84

1.03
1.14
1.53

0.93
1.03
1.38

17.06
18.88
23.38

13.32
15.64
20.5

13.32
15.64
20.5

13.32
15.64
20.5

Z 26215

5.18

12.24

1.53

1.28

1.02

0.85

0.77

17.21

11.33

11.33

12.23

Z 26218
Z 26220

6.22
6.91

16.48
18.96

2.06
2.37

1.72
1.98

1.37
1.58

1.14
1.32

1.03
1.19

20.55
22.7

15.00
17.45

15.00
17.45

15.33
17.45

Z 26225

8.63

24.48

3.06

2.55

2.04

1.70

1.53

28.19

23.51

23.51

23.51

Z 30218

6.85

17.36

2.17

1.81

1.45

1.21

1.09

29.66

16.19

16.19

18.31

Z 30220

7.61

20.88

2.61

2.18

1.74

1.45

1.31

32.85

19.36

19.36

20.64

Z 30225

9.52

28.24

3.53

2.94

2.35

1.96

1.77

40.74

26.84

26.84

27.61

Z 23215

4.53

9.69

1.14

0.95

0.76

0.63

0.57

10.49

8.93

8.93

8.93

Z 23218

5.44

12.58

1.48

1.23

0.99

0.82

0.74

12.51

11.54

11.54

11.54

Z 23220

6.04

13.94

1.64

1.37

1.09

0.91

0.82

13.84

13.28

13.28

13.28

Z 23225

7.55

18.79

2.21

1.84

1.47

1.23

1.11

17.13

17.13

17.13

17.13

Z 25215

4.76

10.29

1.21

1.01

0.81

0.67

0.61

12.67

9.53

9.53

9.53

Z 25218

5.71

13.94

1.64

1.37

1.09

0.91

0.82

15.11

12.54

12.54

12.54

Z 25220

6.34

15.47

1.82

1.52

1.21

1.01

0.91

16.73

14.72

14.72

14.72

Z 25225

7.93

20.83

2.45

2.04

1.63

1.36

1.23

20.71

19.29

19.29

19.29

Z 26215

5.18

11.56

1.36

1.13

0.91

0.76

0.68

15.25

10.67

10.67

10.67

Z 26218

6.22

15.47

1.82

1.52

1.21

1.01

0.91

18.2

14.12

14.12

14.12

Z 26220

6.91

17.85

2.10

1.75

1.40

1.17

1.05

20.15

16.42

16.42

16.42

Z 26225

8.63

23.04

2.71

2.26

1.81

1.51

1.36

24.97

22.13

22.13

22.13

Z 30218

6.85

16.41

1.93

1.61

1.29

1.07

0.97

26.27

15.23

15.23

15.23

Z 30220

7.61

19.64

2.31

1.93

1.54

1.28

1.16

29.1

18.23

18.23

18.23

Z30225

9.52

26.61

3.13

2.61

2.09

1.74

1.57

36.09

25.26

25.26

25.26

Span 8.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 14 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 9.00 M

BUTT SYSTEM

Z 23215

4.53

9.18

1.02

0.85

0.68

0.57

0.51

9.35

8.45

8.45

8.45

9.21

Z 23218

5.44

11.88

1.32

1.1

0.88

0.73

0.66

11.15

10.89

10.89

10.89

11.58

Z 23220

6.04

13.14

1.46

1.22

0.97

0.81

0.73

12.35

12.55

12.55

12.55

13.00

Z 23225

7.55

17.73

1.97

1.64

1.31

1.09

0.99

15.28

16.40

16.40

16.40

16.50

Z 25215

4.76

9.72

1.08

0.90

0.72

0.60

0.54

11.30

9.00

9.00

9.00

9.00

Z 25218
Z 25220
Z 25225

5.71
6.34
7.93

13.23
14.58
19.62

1.47
1.62
2.18

1.23
1.35
1.82

0.98
1.08
1.45

0.82
0.9
1.21

0.74
0.81
1.09

13.48
14.92
18.47

11.84
13.9
18.22

11.84
13.9
18.22

11.84
13.9
18.22

12.44
13.9
18.22

Z 26215

5.18

10.89

1.21

1.01

0.81

0.67

0.61

13.60

10.08

10.08

10.08

12.26

Z 26218
Z 26220

6.22
6.91

14.58
16.83

1.62
1.87

1.35
1.56

1.08
1.25

0.9
1.04

0.81
0.94

16.24
17.98

13.34
15.51

13.34
15.51

13.34
15.51

15.78
18.22

Z 26225

8.63

21.69

2.41

2.01

1.61

1.34

1.21

22.28

20.9

20.9

20.9

23.5

Z 30218

6.85

15.48

1.72

1.43

1.15

0.96

0.86

23.43

14.39

14.39

14.39

17.96

Z 30220

7.61

18.54

2.06

1.72

1.37

1.14

1.03

25.96

17.21

17.21

17.21

20.49

Z30225

9.52

25.11

2.79

2.33

1.86

1.55

1.40

32.19

23.86

23.86

23.86

28.37

Z 25215

4.76

9.22

0.97

0.81

0.65

0.54

0.49

10.14

8.52

8.52

8.52

8.83

Z 25218

5.71

12.45

1.31

1.09

0.87

0.73

0.66

12.10

11.22

11.22

11.22

11.22

Z 25220

6.34

13.78

1.45

1.21

0.97

0.81

0.73

13.39

13.17

13.17

13.17

13.17

Z 25225

7.93

18.62

1.96

1.63

1.31

1.09

0.98

16.58

17.26

17.26

17.26

17.26

Z 26215

5.18

10.36

1.09

0.91

0.73

0.61

0.55

12.21

9.54

9.54

9.54

11.25

Z 26218

6.22

13.87

1.46

1.22

0.97

0.81

0.73

14.57

12.64

12.64

12.64

14.39

Z 26220

6.91

15.96

1.68

1.40

1.12

0.93

0.84

16.13

14.69

14.69

14.69

16.56

Z 26225

8.63

20.62

2.17

1.81

1.45

1.21

1.09

20.00

19.8

19.8

19.8

21.36

Z 30218

6.85

14.63

1.54

1.28

1.03

0.86

0.77

21.03

13.63

13.63

13.63

16.56

Z 30220

7.61

17.58

1.85

1.54

1.23

1.03

0.93

23.29

16.31

16.31

16.31

19.07

Z30225

9.52

23.75

2.5

2.08

1.67

1.39

1.25

28.89

22.6

22.6

22.6

25.91

Span 8.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 15 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 5.00 M

OVERLAP SYSTEM

Z 17215

3.45

13.60

2.72

2.27

1.81

1.51

1.36

14.80

18.10

Z 17218

4.14

17.75

3.55

2.96

2.37

1.97

1.78

17.00

23.65

Z 17220

4.60

20.05

4.01

3.34

2.67

2.23

2.01

19.00

26.70

Z 17225

5.75

25.40

5.08

4.23

3.39

2.82

2.54

23.15

33.75

Z 18215

3.57

14.80

2.96

2.47

1.97

1.64

1.48

17.05

19.65

Z 18218
Z 18220
Z 18225

4.28
4.76
5.92

19.50
22.00
27.70

3.90
4.4
5.54

3.25
3.67
4.62

2.60
2.93
3.69

2.17
2.44
3.08

1.95
2.20
2.77

19.95
21.95
27.00

25.9
29.35
36.80

Z 20215

3.92

16.50

3.30

2.75

2.20

1.83

1.65

22.90

21.85

Z 20218
Z 20220

4.7
5.23

21.85
25.65

4.37
5.13

3.64
4.28

2.91
3.42

2.43
2.85

2.19
2.57

27.00
29.70

29.10
34.00

Z 20225

6.53

33.45

6.69

5.58

4.46

3.72

3.35

36.10

44.50

Span 5.50 M
Z 17215

3.45

12.32

2.24

1.87

1.49

1.24

1.12

12.27

16.34

Z 17218

4.14

16.34

2.97

2.48

1.98

1.65

1.49

14.3

21.67

Z 17220

4.60

18.43

3.35

2.79

2.23

1.86

1.68

15.73

24.48

Z 17225

5.75

23.38

4.25

3.54

2.83

2.36

2.13

19.20

30.97

Z 18215

3.57

13.2

2.40

2.00

1.60

1.33

1.20

14.03

17.55

Z 18218

4.28

17.77

3.23

2.69

2.15

1.79

1.62

16.56

23.65

Z 18220

4.76

20.19

3.67

3.06

2.45

2.04

1.84

18.15

26.84

Z 18225

5.92

25.36

4.61

3.84

3.07

2.56

2.31

22.11

33.72

Z 20215

3.92

14.47

2.63

2.19

1.75

1.46

1.32

19.03

19.25

Z 20218

4.70

19.58

3.56

2.97

2.37

1.98

1.78

22.39

26.02

Z 20220

5.23

23.21

4.22

3.52

2.81

2.34

2.11

24.42

30.91

Z 20225

6.53

30.53

5.55

4.63

3.7

3.08

2.78

29.76

40.70

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 16 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 6.00 M

OVERLAP SYSTEM

Z 18215

3.57

11.58

1.93

1.61

1.29

1.07

0.97

11.76

15.42

Z 18218

4.28

15.42

2.57

2.14

1.71

1.43

1.29

13.86

20.52

Z 18220

4.76

17.58

2.93

2.44

1.95

1.63

1.47

15.12

23.34

Z 18225

5.92

22.20

3.70

3.08

2.47

2.06

1.85

18.42

29.46

Z 20215

3.92

12.90

2.15

1.79

1.43

1.19

1.08

15.78

17.16

Z 20218
Z 20220
Z 20225

4.70
5.23
6.53

17.16
20.22
26.76

2.86
3.37
4.46

2.38
2.81
3.72

1.91
2.25
2.97

1.59
1.87
2.48

1.43
1.69
2.23

18.48
20.40
24.90

22.8
26.88
35.46

Z 23215

4.53

13.92

2.32

1.93

1.55

1.29

1.16

24.30

18.48

Z 23218
Z 23220

5.44
6.04

19.80
23.40

3.30
3.90

2.75
3.25

2.20
2.60

1.83
2.17

1.65
1.95

28.32
31.32

26.34
31.08

Z 23225

7.55

33.24

5.54

4.62

3.69

3.08

2.77

38.28

44.16

Span 6.50 M
Z 18215

3.57

10.27

1.58

1.32

1.05

0.88

0.79

10.01

13.72

Z 18218

4.28

13.59

2.09

1.74

1.39

1.16

1.05

11.70

18.07

Z 18220

4.76

15.47

2.38

1.98

1.59

1.32

1.19

12.87

20.61

Z 18225

5.92

19.50

3.00

2.5.

2.00

1.67

1.50

15.73

25.94

Z 20215

3.92

11.57

1.78

1.48

1.19

0.99

0.89

13.46

15.41

Z 20218

4.70

15.21

2.34

1.95

1.56

1.30

1.17

15.80

20.28

Z 20220

5.23

17.88

2.75

2.29

1.83

1.53

1.38

17.36

23.79

Z 20225

6.53

23.6

3.63

3.03

2.42

2.02

1.82

21.19

31.2

Z 23215

4.53

12.68

1.95

1.63

1.30

1.08

0.98

20.61

16.64

Z 23218

5.44

17.81

2.74

2.28

1.83

1.52

1.37

24.12

23.66

Z 23220

6.04

20.93

3.22

2.68

2.15

1.79

1.61

26.78

27.69

Z 23225

7.55

29.45

4.53

3.78

3.02

2.52

2.27

32.57

39.20

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 17 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 7.00 M

OVERLAP SYSTEM

Z 18215

3.57

9.24

1.32

1.10

0.88

0.73

0.66

8.54

12.32

Z 18218

4.28

12.18

1.74

1.45

1.16

0.97

0.87

10.01

16.17

Z 18220

4.76

13.79

1.97

1.64

1.31

1.09

0.99

11.06

18.34

Z 18225

5.92

17.29

2.47

2.06

1.65

1.37

1.24

13.51

23.03

Z 20215

3.92

10.5

1.50

1.25

1.00

0.83

0.75

11.62

13.93

Z 20218
Z 20220
Z 20225

4.70
5.23
6.53

13.65
16.03
20.86

1.95
2.29
2.98

1.63
1.91
2.48

1.30
1.53
1.99

1.08
1.27
1.66

0.98
1.15
1.49

13.58
14.91
18.2

18.2
21.28
27.86

Z 23215

4.53

11.83

1.69

1.41

1.13

0.94

0.85

17.64

15.54

Z 23218

5.44

16.17

2.31

1.93

1.54

1.28

1.16

20.72

21.49

Z 23225

7.55

26.25

3.75

3.13

2.5

2.08

1.88

28.07

34.93

Z 25215

4.76

11.83

1.69

1.41

1.13

0.94

0.85

21.56

15.68

Z 25218

5.71

17.01

2.43

2.03

1.62

1.35

1.22

25.34

22.82

Z 25225
Z 26215
Z 26218
Z 26220
Z 26225

7.93
5.18
6.22
6.91
8.63

28.77
12.32
18.20
22.19
31.29

4.11
1.76
2.6
3.17
4.47

3.43
1.47
2.17
2.64
3.73

2.74
1.17
1.73
2.11
2.98

33.53
25.76
30.10
33.46
40.46

38.15
16.45
24.22
29.40
41.79

Z 18215

3.57

10.05

1.34

1.12

2.28 2.06
0.98 0.88
1.44 1.30
1.76 1.59
2.48 2.24
Span 7.50 M
0.89
0.74 0.67

7.65

13.43

Z 18218

4.28

12.38

1.65

1.38

1.10

0.92

0.83

8.93

17.40

Z 18220

4.76

13.65

1.82

1.52

1.21

1.01

0.91

9.90

19.58

Z 18225

5.92

16.88

2.25

1.88

1.50

1.25

1.13

12.08

24.45

Z 20218

4.70

14.85

1.98

1.65

1.32

1.10

0.99

12.08

19.73

Z 20220

5.23

16.65

2.22

1.85

1.48

1.23

1.11

13.35

22.88

Z 20225

6.53

21.15

2.82

2.35

1.88

1.57

1.41

16.35

29.63

Z 23218

5.44

18.15

2.42

2.02

1.61

1.34

1.21

18.68

24.08

Z 23220

6.04

20.78

2.77

2.31

1.85

1.54

1.39

20.48

27.6

Z 23225

7.55

28.28

3.77

3.14

2.51

2.09

1.89

25.13

37.58

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 18 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 7.50 M

OVERLAP SYSTEM

Z 25218

5.71

20.55

2.74

2.28

1.83

1.52

1.37

22.50

25.88

Z 25220

6.34

23.85

3.18

2.65

2.12

1.77

1.59

24.83

30.15

Z 25225

7.93

31.05

4.14

3.45

2.76

2.30

2.07

30.30

41.48

Z 26218

6.22

21.38

2.85

2.38

1.90

1.58

1.43

27.15

28.43

Z 26220

6.91

25.35

3.38

2.82

2.25

1.88

1.69

29.70

33.68

Z 26225

8.63

34.35

4.58

3.82

3.05

2.54

2.29

36.68

45.75

Span 8.00 M
Z 20215

3.92

11.04

1.38

1.15

0.92

0.77

0.69

8.96

14.72

Z 20218

4.70

13.92

1.74

1.45

1.16

0.97

0.87

10.56

18.56

Z 20220

5.23

15.68

1.96

1.63

1.31

1.09

0.98

11.60

21.60

Z 20225

6.53

19.84

2.48

2.07

1.65

1.38

1.24

14.32

27.84

Z 23218

5.44

17.12

2.14

1.78

1.43

1.19

1.07

16.32

22.8

Z 23220

6.04

19.60

2.45

2.04

1.63

1.36

1.23

17.92

26.00

Z 23225

7.55

26.56

3.32

2.77

2.21

1.84

1.66

22.16

35.44

Z 25218

5.71

18.40

2.3

1.92

1.53

1.28

1.15

19.60

24.48

Z 25220

6.34

21.44

2.68

2.23

1.79

1.49

1.34

21.76

28.48

Z 25225

7.93

29.36

3.67

3.06

2.45

2.04

1.84

26.72

39.04

Z 26218

6.22

20.32

2.54

2.12

1.69

1.41

1.27

23.84

26.96

Z 26220

6.91

24.00

3.00

2.50

2.00

1.67

1.50

26.08

31.84

Z 26225

8.63

32.48

4.06

3.38

2.71

2.26

2.03

32.16

43.04

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 19 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 8.50 M

OVERLAP SYSTEM

Z 20215

3.92

10.46

1.23

1.03

0.82

0.68

0.62

7.99

13.94

Z 20218

4.70

13.09

1.54

1.28

1.03

0.86

0.77

9.35

17.60

Z 20220

5.23

14.71

1.73

1.44

1.15

0.96

0.87

10.37

20.40

Z 20225

6.53

18.70

2.20

1.83

1.47

1.22

1.10

12.58

26.27

Z 23215

4.53

12.24

1.44

1.20

0.96

0.80

0.72

12.24

16.32

Z 23218
Z 23220
Z 23225

5.44
6.04
7.55

16.24
18.53
25.16

1.91
2.18
2.96

1.59
1.82
2.47

1.27
1.45
1.97

1.06
1.21
1.64

0.96
1.09
1.48

14.37
15.9
19.47

21.59
24.65
33.49

Z 25215

4.76

12.75

1.50

1.25

1.00

0.83

0.75

14.71

17.00

Z 25218

5.71

17.51

2.06

1.72

1.37

1.14

1.03

17.34

23.29

Z 25220

6.34

20.32

2.39

1.99

1.59

1.33

1.20

19.21

26.95

Z 25225

7.93

27.63

3.25

2.71

2.17

1.81

1.63

23.46

36.98

Z 26215

5.18

13.86

1.63

1.36

1.09

0.91

0.82

17.85

18.45

Z 26218

6.22

19.3

2.27

1.89

1.51

1.26

1.14

21.00

25.67

Z 26220

6.91

22.78

2.68

2.23

1.79

1.49

1.34

22.95

30.26

Z 26225

8.63

30.69

3.61

3.01

2.41

2.01

1.81

28.39

Z 30218

6.85

19.98

2.35

1.96

1.57

1.31

1.18

30.77

26.52

Z 30220

7.61

24.57

2.89

2.41

1.93

1.61

1.45

34.00

32.64

Z 30225

9.52

34.68

4.08

3.40

2.72

2.27

2.04

41.4

46.16

Z 25215

4.76

10.29

1.21

1.01

0.81

0.67

0.61

12.67

9.53

9.53

9.53

Z 25218

5.71

13.94

1.64

1.37

1.09

0.91

0.82

15.11

12.54

12.54

12.54

Z 25220

6.34

15.47

1.82

1.52

1.21

1.01

0.91

16.73

14.72

14.72

14.72

Z 25225

7.93

20.83

2.45

2.04

1.63

1.36

1.23

20.71

19.29

19.29

19.29

Z 26215

5.18

11.56

1.36

1.13

0.91

0.76

0.68

15.25

10.67

10.67

10.67

Z 26218

6.22

15.47

1.82

1.52

1.21

1.01

0.91

18.2

14.12

14.12

14.12

Z 26220

6.91

17.85

2.10

1.75

1.4

1.17

1.05

20.15

16.42

16.42

16.42

Z 26225

8.63

23.04

2.71

2.26

1.81

1.51

1.36

24.97

22.13

22.13

22.13

Z 30218

6.85

16.41

1.93

1.61

1.29

1.07

0.97

26.27

15.23

15.23

15.23

Z 30220

7.61

19.64

2.31

1.93

1.54

1.28

1.16

29.1

18.23

18.23

18.23

Z30225

9.52

26.61

3.13

2.61

2.09

1.74

1.57

36.09

25.26

25.26

25.26

40.89

Span 9.00 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 20 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 9.50 M

OVERLAP SYSTEM

Z 20215

3.92

9.87

1.10

0.91

0.73

0.61

0.55

7.13

13.17

Z 20218

4.70

12.36

1.37

1.14

0.92

0.76

0.69

8.34

16.62

Z 20220

5.23

13.89

1.54

1.29

1.03

0.86

0.77

9.25

19.27

Z 20225

6.53

17.66

1.96

1.64

1.31

1.09

0.98

11.22

24.81

Z 23215

4.53

11.56

1.28

1.07

0.86

0.71

0.64

10.92

15.41

Z 23218
Z 23220
Z 23225

5.44
6.04
7.55

15.33
17.50
23.76

1.7
1.94
2.64

1.42
1.62
2.2

1.14
1.30
1.76

0.95
1.08
1.47

0.85
0.97
1.32

12.81
14.18
17.36

20.39
23.28
31.63

Z 25215

4.76

12.04

1.34

1.11

0.89

0.74

0.67

13.12

16.06

Z 25218

5.71

16.54

1.84

1.53

1.22

1.02

0.92

15.47

22

Z 25220

6.34

19.19

2.13

1.78

1.42

1.18

1.07

17.13

25.45

Z 25225

7.93

26.09

2.90

2.42

1.93

1.61

1.45

20.93

34.92

Z 26215

5.18

13.09

1.45

1.21

0.97

0.81

0.73

15.92

17.42

Z 26218

6.22

18.22

2.02

1.69

1.35

1.12

1.01

18.73

24.24

Z 26220

6.91

21.51

2.39

1.99

1.59

1.33

1.20

20.47

28.58

Z 26225

8.63

28.98

3.22

2.68

2.15

1.79

1.61

25.32

Z 30218

6.85

18.87

2.10

1.75

1.40

1.16

1.05

27.45

25.05

Z 30220

7.61

23.20

2.58

2.15

1.72

1.43

1.29

30.33

30.83

Z 30225

9.52

32.75

3.64

3.03

2.43

2.02

1.82

36.92

43.59

38.61

Span 10.00 M
Z 23215

4.53

8.89

0.89

0.74

0.59

0.49

0.44

5.77

11.85

Z 23218

5.44

11.13

1.11

0.93

0.74

0.62

0.56

6.76

14.96

Z 23220

6.04

12.50

1.25

1.04

0.83

0.69

0.62

7.49

17.34

Z 23225
Z 25215
Z 25218
Z 25220
Z 25225
Z 26215
Z 26218
Z 26220
Z 26225
Z 30218
Z 30220
Z 30225

7.55
4.76
5.71
6.34
7.93
5.18
6.22
6.91
8.63
6.85
7.61
9.52

15.90
10.40
13.80
15.75
21.39
10.84
14.88
17.27
23.48
11.78
16.40
19.36

1.59
1.04
1.38
1.58
2.14
1.08
1.49
1.73
2.35
1.18
1.64
1.94

1.32
0.87
1.15
1.31
1.78
0.90
1.24
1.44
1.96
0.98
1.37
1.61

1.06
0.69
0.92
1.05
1.43
0.72
0.99
1.15
1.57
0.79
1.09
1.29

0.88
0.58
0.77
0.88
1.19
0.60
0.83
0.96
1.30
0.65
0.91
1.08

0.79
0.52
0.69
0.79
1.07
0.54
0.74
0.86
1.17
0.59
0.82
0.97

9.09
8.84
10.38
11.48
14.06
10.62
12.53
13.88
16.95
12.90
15.17
16.58

22.33
13.87
18.35
20.95
28.47
14.45
19.80
22.90
31.43
15.68
21.82
25.72

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 21 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 5.00 M

SLEEVE SYSTEM

Z 17215

3.45

11.20

2.24

1.87

1.49

1.24

1.12

14.80

10.40

Z 17218

4.14

14.25

2.85

2.38

1.90

1.58

1.43

17.00

13.40

Z 17220

4.60

16.00

3.20

2.67

2.13

1.78

1.60

19.00

15.05

Z 17225

5.75

19.90

3.98

3.32

2.65

2.21

1.99

23.15

18.50

Z 18215

3.57

12.45

2.49

2.08

1.66

1.38

1.25

17.05

11.55

Z 18218
Z 18220
Z 18225

4.28
4.76
5.92

15.75
17.55
21.60

3.15
3.51
4.32

2.63
2.93
3.60

2.10
2.34
2.88

1.75
1.95
2.40

1.58
1.76
2.16

19.95
21.95
27.00

14.65
16.40
20.10

Z 20215

3.92

14.65

2.93

2.44

1.95

1.63

1.47

22.90

13.65

Z 20218
Z 20220

4.70
5.23

18.10
20.80

3.62
4.16

3.02
3.47

2.41
2.77

2.01
2.31

1.81
2.08

27.00
29.70

16.85
19.35

Z 20225

6.53

26.35

5.27

4.39

3.51

2.93

2.64

36.10

24.60

Span 5.50 M
Z 17215

3.45

10.18

1.85

1.54

1.23

1.03

0.93

12.27

9.52

Z 17218

4.14

12.87

2.34

1.95

1.56

1.30

1.17

14.30

12.05

Z 17220

4.60

14.47

2.63

2.19

1.75

1.46

1.32

15.73

13.42

Z 17225

5.75

18.04

3.28

2.73

2.19

1.82

1.64

19.20

18.92

Z 18215

3.57

11.22

2.04

1.70

1.36

1.13

1.02

14.03

10.45

Z 18218

4.28

14.25

2.59

2.16

1.73

1.44

1.30

16.56

13.26

Z 18220

4.76

15.95

2.90

2.42

1.93

1.61

1.45

18.15

14.85

Z 18225

5.92

19.69

3.58

2.98

2.39

1.99

1.79

22.11

18.32

Z 20215

3.92

13.31

2.42

2.02

1.61

1.34

1.21

19.03

12.43

Z 20218

4.70

16.34

2.97

2.48

1.98

1.65

1.49

22.39

15.18

Z 20220

5.23

18.81

3.42

2.85

2.28

1.90

1.71

24.42

17.49

Z 20225

6.53

23.82

4.33

3.61

2.89

2.41

2.17

29.76

22.33

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Page 22 of 27
Working Loads

Total
UDL KN
Section
Ref

Allowable downward loads Total UDL


in Kn/m2
Kn

Weight
Kg/m

[Purlin Centres in
mms]
1000

1200

1500

1800

Total Uplifting Loads in KN

Deflection [Metal cladding] No of Antisag Rods

2000 Span/180

Span 6.00 M

SLEEVE SYSTEM

Z 18215

3.57

10.26

1.71

1.43

1.14

0.95

0.86

11.76

9.60

Z 18218

4.28

13.02

2.17

1.81

1.45

1.21

1.09

13.86

12.12

Z 18220

4.76

14.52

2.42

2.02

1.61

1.34

1.21

15.12

13.56

Z 18225

5.92

17.88

2.98

2.48

1.99

1.66

1.49

18.42

16.74

Z 20215

3.92

12.18

2.03

1.69

1.35

1.13

1.02

15.78

11.28

Z 20218
Z 20220
Z 20225

4.70
5.23
6.53

15.00
17.16
21.90

2.50
2.86
3.65

2.08
2.38
3.04

1.67
1.91
2.43

1.39
1.59
2.03

1.25
1.43
1.83

18.48
20.40
24.90

13.92
16.02
20.28

Z 23215

4.53

13.86

2.31

1.93

1.54

1.28

1.16

24.30

13.74

Z 23218
Z 23220

5.44
6.04

18.72
21.00

3.12
3.50

2.60
2.92

2.08
2.33

1.73
1.94

1.56
1.75

28.32
31.32

17.40
19.50

Z 23225

7.55

27.96

4.66

3.88

3.11

2.59

2.33

38.28

25.98

Span 6.50 M
Z 18215

3.57

9.43

1.45

1.21

0.97

0.81

0.73

10.01

8.78

Z 18218

4.28

12.03

1.85

1.54

1.23

1.03

0.93

11.70

11.18

Z 18220

4.76

13.39

2.06

1.72

1.37

1.14

1.03

12.87

12.42

Z 18225

5.92

16.51

2.54

2.12

1.69

1.41

1.27

15.73

15.34

Z 20215

3.92

11.18

1.72

1.43

1.15

0.96

0.86

13.46

10.47

Z 20218

4.70

13.78

2.12

1.77

1.41

1.18

1.06

15.80

12.87

Z 20220

5.23

15.80

2.43

2.03

1.62

1.35

1.22

17.36

14.69

Z 20225

6.53

20.15

3.10

2.58

2.07

1.72

1.55

21.19

18.79

Z 23215

4.53

12.68

1.95

1.63

1.30

1.08

0.98

20.61

12.68

Z 23218

5.44

17.36

2.67

2.23

1.78

1.48

1.34

24.12

16.25

Z 23220

6.04

19.31

2.97

2.48

1.98

1.65

1.49

26.78

17.36

Z 23225

7.55

25.74

3.96

3.30

2.64

2.20

1.98

32.57

24.05

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto
roof slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


as per AISI 3
d) Sag rods are located at equal distances

1/3 %

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Working Loads
Allowable downward loads Total UDL
Total Uplifting Loads in KN
in Kn/m2
Kn
[Purlin Centres in
Deflection [Metal cladding] No of Antisag Rods
mms]

Total
UDL KN
Section
Ref

Page 23 of 27

Weight
Kg/m
1000

1200

1500

1800

2000 Span/180

Span 7.00 M

SLEEVE SYSTEM

Z 18215

3.57

8.75

1.25

1.04

0.83

0.69

0.63

8.54

8.19

Z 18218

4.28

11.13

1.59

1.33

1.06

0.88

0.80

10.01

10.36

Z 18220

4.76

12.39

1.77

1.48

1.18

0.98

0.89

11.06

1.55

Z 18225

5.92

15.26

2.18

1.82

1.45

1.21

1.09

13.51

14.21

Z 20215

3.92

10.36

1.48

1.23

0.99

0.82

0.74

11.62

9.66

Z 20218

4.70

12.74

1.82

1.52

1.21

1.01

0.91

13.58

11.90

Z 20220

5.23

14.63

2.09

1.74

1.39

1.16

1.05

14.91

13.65

Z 20225

6.53

18.55

2.65

2.21

1.77

1.47

1.33

18.20

17.29

Z 23215

4.53

11.83

1.69

1.41

1.13

0.94

0.85

17.64

11.76

Z 23218

5.44

15.96

2.28

1.90

1.52

1.27

1.14

20.72

14.84

Z 23220

6.04

17.92

2.56

2.13

1.71

1.42

1.28

22.96

16.66

Z 23225

7.55

23.87

3.41

2.84

2.27

1.89

1.71

28.07

22.19

Z 25215

4.76

11.69

1.67

1.39

1.11

0.93

0.84

21.56

12.46

Z 25218

5.71

17.01

2.43

2.03

1.62

1.35

1.22

25.34

16.38

Z 25220

6.34

19.88

2.84

2.37

1.89

1.58

1.42

27.58

18.62

Z 25225

7.93

26.53

3.79

3.16

2.53

2.11

1.90

33.53

24.57

Z 26215

5.18

12.04

1.72

1.43

1.15

0.96

0.86

25.76

14.00

Z 26218

6.22

18.20

2.60

2.17

1.73

1.44

1.30

30.10

18.34

Z 26220

6.91

22.19

3.17

2.64

2.11

1.76

1.59

33.46

21.07

Z 26225

8.63

29.54

4.22

3.52

2.81

2.34

2.11

40.46

27.30

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Working Loads
Allowable downward loads Total UDL
Total Uplifting Loads in KN
in Kn/m2
Kn
[Purlin Centres in
Deflection [Metal cladding] No of Antisag Rods
mms]

Total
UDL KN
Section
Ref

Page 24 of 27

Weight
Kg/m
1000

1200

1500

1800

2000 Span/180

Span 7.50 M

SLEEVE SYSTEM

Z 18215

3.57

8.33

1.11

0.93

0.74

0.62

0.56

7.65

7.73

Z 18218

4.28

10.58

1.41

1.18

0.94

0.78

0.71

8.93

9.83

Z 18220

4.76

11.78

1.57

1.31

1.05

0.87

0.79

9.90

10.95

Z 18225

5.92

14.03

1.87

1.56

1.25

1.04

0.94

12.08

13.50

Z 20215

3.92

9.83

1.31

1.09

0.87

0.73

0.66

10.35

9.15

Z 20218

4.70

12.08

1.61

1.34

1.07

0.89

0.81

12.08

11.33

Z 20220

5.23

13.88

1.85

1.54

1.23

1.03

0.93

13.35

12.90

Z 20225

6.53

17.55

2.34

1.95

1.56

1.30

1.17

16.35

17.55

Z 23215

4.53

11.93

1.59

1.33

1.06

0.88

0.80

15.90

11.10

Z 23218

5.44

15.15

2.02

1.68

1.35

1.12

1.01

18.68

14.10

Z 23220

6.04

17.03

2.27

1.89

1.51

1.26

1.14

20.48

16.05

Z 23225

7.55

22.65

3.02

2.52

2.01

1.68

1.51

25.13

21.08

Z 25215

4.76

12.68

1.69

1.41

1.13

0.94

0.85

19.20

11.85

Z 25218

5.71

16.65

2.22

1.85

1.48

1.23

1.11

22.50

15.45

Z 25220

6.34

18.90

2.52

2.10

1.68

1.40

1.26

24.83

17.55

Z 25225

7.93

25.20

3.36

2.80

2.24

1.87

1.68

30.30

23.40

Z 26215

5.18

14.25

1.90

1.58

1.27

1.06

0.95

22.95

11.93

Z 26218

6.22

18.75

2.50

2.08

1.67

1.39

1.25

27.15

17.48

Z 26220

6.91

21.53

2.87

2.39

1.91

1.59

1.44

29.70

20.03

Z 26225

8.63

27.90

3.72

3.10

2.48

2.07

1.86

36.68

25.95

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet

Working Loads
Allowable downward loads Total UDL
Total Uplifting Loads in KN
in Kn/m2
Kn
[Purlin Centres in
Deflection [Metal cladding] No of Antisag Rods
mms]

Total
UDL KN
Section
Ref

Page 25 of 27

Weight
Kg/m
1000

1200

1500

1800

2000 Span/180

Span 8.00 M

SLEEVE SYSTEM

Z 20215

3.92

9.2

1.15

0.96

0.77

0.64

0.58

8.96

8.56

Z 20218

4.70

11.36

1.42

1.18

0.95

0.79

0.71

10.56

10.56

Z 20220

5.23

13.04

1.63

1.36

1.09

0.91

0.82

11.60

12.08

Z 20225

6.53

16.48

2.06

1.72

1.37

1.14

1.03

14.32

15.44

Z 23215

4.53

11.12

1.39

1.16

0.93

0.77

0.70

13.84

10.64

Z 23218

5.44

14.24

1.78

1.48

1.19

0.99

0.89

16.32

13.28

Z 23220

6.04

16.00

2.00

1.67

1.33

1.11

1.00

17.92

14.88

Z 23225

7.55

21.28

2.66

2.22

1.77

1.48

1.33

22.16

19.84

Z 25215

4.76

11.92

1.49

1.24

0.99

0.83

0.75

15.36

11.36

Z 25218

5.71

15.52

1.94

1.62

1.29

1.08

0.97

19.60

14.48

Z 25220

6.34

17.68

2.21

1.84

1.47

1.23

1.11

21.76

16.40

Z 25225

7.93

23.52

2.94

2.45

1.96

1.63

1.47

26.72

21.84

Z 26215

5.18

13.28

1.66

1.38

1.11

0.92

0.83

20.08

14.72

Z 26218

6.22

17.44

2.18

1.82

1.45

1.21

1.09

23.84

18.64

Z 26220

6.91

20.08

2.51

2.09

1.67

1.39

1.26

26.08

21.44

Z 26225

8.63

26.08

3.26

2.72

2.17

1.81

1.63

32.16

27.20

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet


Total
UDL KN
Section
Ref

Weight
Kg/m
1000

Page 26 of 27
Working Loads
Allowable downward loads Total UDL
Total Uplifting Loads in KN
in Kn/m2
Kn
[Purlin Centres in
Deflection [Metal cladding] No of Antisag Rods
mms]
1200 1500 1800 2000 Span/180
0
1
2
3
Span 8.50 M

SLEEVE SYSTEM

Z 20215

3.92

8.67

1.02

0.85

0.68

0.57

0.51

7.99

8.08

Z 20218

4.70

10.63

1.25

1.04

0.83

0.69

Z 20220

5.23

12.24

1.44

1.20

0.96

0.80

0.63

9.35

0.72

10.37

9.95

11.39

Z 20225

6.53

15.56

1.83

1.53

1.22

Z 23215

4.53

10.46

1.23

1.03

0.82

1.02

0.92

12.58

0.68

0.62

12.24

14.45

9.78

Z 23218

5.44

13.35

1.57

1.31

1.05

0.87

0.79

14.37

12.41

Z 23220

6.04

14.96

1.76

Z 23225

7.55

19.89

2.34

1.47

1.17

0.98

1.95

1.56

1.30

0.88

15.90

13.94

1.17

19.47

18.53

Z 25215

4.76

11.22

Z 25218

5.71

14.62

1.32

1.10

0.88

1.72

1.43

1.15

0.73

0.66

14.71

10.37

0.96

0.86

17.34

13.60

Z 25220

6.34

Z 25225

7.93

16.58

1.95

1.63

22.10

2.60

2.17

1.30

1.08

0.98

19.21

15.47

1.73

1.44

1.30

23.46

20.57

Z 26215
Z 26218

5.18

12.50

1.47

6.22

16.41

1.93

1.23

0.98

0.82

0.74

17.85

13.35

1.61

1.29

1.07

0.97

21.00

16.66

Z 26220

6.91

18.87

Z 26225

8.63

24.48

2.22

1.85

1.48

1.23

1.11

22.95

18.87

2.88

2.40

1.92

1.60

1.44

28.39

23.89

Z 30218

6.85

Z 30220

7.61

17.85

2.10

1.75

1.40

1.17

1.05

30.77

19.38

21.42

2.52

2.10

1.68

1.40

1.26

34.00

22.03

Z 30225

9.52

28.56

3.36

2.80

2.24

1.87

1.68

41.40

29.33

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Cold Formed Profile

ZPurlin

Product Data Sheet


Total
UDL KN
Section
Ref

Weight
Kg/m
1000

Page 27 of 27
Working Loads
Allowable downward loads Total UDL
Total Uplifting Loads in KN
in Kn/m2
Kn
[Purlin Centres in
Deflection [Metal cladding] No of Antisag Rods
mms]
1200 1500 1800 2000 Span/180
0
1
2
3
Span 9.00 M

SLEEVE SYSTEM

Z 20215

3.92

8.19

0.91

0.76

0.61

0.51

0.45

7.13

7.63

Z 20218

4.70

10.03

1.11

0.93

0.74

0.62

0.56

8.34

Z 20220

5.23

11.56

1.28

1.07

0.86

0.71

0.64

9.25

9.39

10.76

Z 20225

6.53

14.69

1.63

1.36

1.09

0.91

0.82

11.22

Z 23215

4.53

9.87

1.10

0.91

0.73

0.61

0.55

10.92

13.65

9.23

Z 23218

5.44

12.60

1.40

1.17

0.93

0.78

0.70

12.81

11.72

Z 23220

6.04

14.13

1.57

1.31

1.05

0.87

Z 23225

7.55

18.79

2.09

1.74

1.39

1.16

0.78

14.18

13.17

1.04

17.36

17.50

Z 25215

4.76

10.60

1.18

0.98

0.78

Z 25218

5.71

13.81

1.53

1.28

1.02

0.65

0.59

13.12

9.79

0.85

0.77

15.47

12.84

Z 25220

6.34

15.65

1.74

1.45

Z 25225

7.93

20.87

2.32

1.93

1.16

0.97

0.87

17.13

14.61

1.55

1.29

1.16

20.93

19.43

Z 26215

5.18

11.80

1.31

Z 26218

6.22

15.49

1.72

1.09

0.87

0.73

0.66

15.92

12.60

1.43

1.15

0.96

0.86

18.73

15.73

Z 26220

6.91

17.82

Z 26225

8.63

23.12

1.98

1.65

1.32

1.10

0.99

20.47

17.82

2.57

2.14

1.71

1.43

1.28

25.32

22.56

Z 30218

6.85

Z 30220

7.61

16.86

1.87

1.56

1.25

1.04

0.94

27.45

18.30

20.23

2.25

1.87

1.50

1.25

1.12

30.33

20.79

Z 30225

9.52

26.97

3.00

2.50

2.00

1.67

1.50

36.92

27.70

Z 23215

4.53

7.76

0.82

0.68

0.54

0.45

0.41

6.40

7.23

Z 23218

5.44

9.51

1.00

0.83

0.67

0.56

0.50

7.49

8.90

Z 23220

6.04

10.95

1.15

0.96

0.77

0.64

0.58

8.30

10.19

Z 23225

7.55

13.92

1.47

1.22

0.98

0.81

0.73

10.07

12.93

Z 25215

4.76

9.35

0.98

0.82

0.66

0.55

0.49

9.80

8.75

Z 25218

5.71

11.94

1.26

1.05

0.84

0.70

0.63

11.50

11.10

Z 25220

6.34

13.39

1.41

1.17

0.94

0.78

0.70

12.72

12.47

Z 25225

7.93

17.80

1.87

1.56

1.25

1.04

0.94

15.58

16.58

Z 26215

5.18

10.04

1.06

0.88

0.70

0.59

0.53

11.77

9.28

Z 26218

6.22

13.08

1.38

1.15

0.92

0.76

0.69

13.88

12.17

Z 26220

6.91

14.83

1.56

1.30

1.04

0.87

0.78

15.38

13.84

Z 26225

8.63

19.77

2.08

1.73

1.39

1.16

1.04

18.78

18.40

Z 30218

6.85

11.18

1.18

0.98

0.78

0.65

0.59

14.29

11.94

Z 30220

7.61

14.68

1.55

1.29

1.03

0.86

0.77

16.81

14.91

Z 30225

9.52

16.88

1.78

1.48

1.18

0.99

0.89

18.37

16.88

Span 9.50 M

Notes:
a) Design of Purlins is based on AISI-1996
b) Allowable loads are applicable for 2 or more bays and upto roof
slopes of 3:10 only

c) Allowable capacities for uplift loads are increased by 33


AISI 3
d) Sag rods are located at equal distances

1/3 %

as per

T: +971 6 533 8449


F: +971 6 533 6673
E: info@TigerPROFILES.com
The Roof & Cladding Company
Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isnt intended to replace
engineering judgmentfor support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

Vous aimerez peut-être aussi