The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. "WiMAX," the WiMAX Forum logo, "wiMAX Forum Certified," and the 4Motion(r) logo are trademarks of the WiMAX Forum.
The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. "WiMAX," the WiMAX Forum logo, "wiMAX Forum Certified," and the 4Motion(r) logo are trademarks of the WiMAX Forum.
The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. "WiMAX," the WiMAX Forum logo, "wiMAX Forum Certified," and the 4Motion(r) logo are trademarks of the WiMAX Forum.
funcionar en 4Motion. Procedimiento para Claro Per
Diciembre 2013
MigracionManualCpe1000 Contents 4Motion ii Date Document Name Document Number 17 Diciembre 2013 MigracionManualCpe1000 Version 1 Revision 4 Written By: Title: Customer Support Engineer No. of pages: 12 Rev: B
Copyright 2014 Alvarion Ltd. All rights reserved. The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd. Alvarion Ltd. reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. Alvarion, BreezeCOM, WALKair, WALKnet, BreezeNET, BreezeACCESS, BreezeMAX, BreezeLITE, 4Motion, and/or other products and/or services referenced herein are either registered trademarks, trademarks or service marks of Alvarion Ltd. All other names are or may be the trademarks of their respective owners. WiMAX Forum is a registered trademark of the WiMAX Forum. WiMAX, the WiMAX Forum logo, WiMAX Forum Certified, and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum. Limitation of Liability: (a) Alvarion shall not be liable to the purchaser or to any third party, for any loss of profits, loss of use, interruption of business or for any indirect, special, incidental, punitive or consequential damages of any kind, whether arising under breach of contract, tort (including negligence), strict liability or otherwise and whether based on this agreement or otherwise, even if advised of the possibility of such damages. (b) To the extent permitted by applicable law, in no event shall the liability for damages hereunder of Alvarion or its employees or agents exceed the purchase price paid for the product by purchaser, nor shall the aggregate liability for damages to all parties regarding any product exceed the purchase price paid for that product by that party (except in the case of a breach of a partys confidentiality obligations).
MigracionManualCpe1000 4Motion 3 Contents 1 Alcance .................................................. 4 2 Antecedentes. ............................................ 4 3 Requerimientos ........................................... 5 3.1.1 PC local. ................................................ 5 3.1.2 Cables ................................................... 5 4 Conexin local al CPE. ................................... 5 4.1.1 Configurar la direccion IP ............................... 5 4.1.2 Acceso Web. .............................................. 5 4.1.3 Acceso Telnet. ........................................... 5 4.1.4 Verificaciones. .......................................... 6 5 Actualizacin de software del CPE. ....................... 7 5.1.1 Carga de software ........................................ 7 6 Configuracin del CPE para 4Motion ....................... 9 6.1.1 Configuracin de parmetros BSID. ........................ 9 6.1.2 Configuracin de parmetros de Radio. ................... 10 6.1.3 Configuracin de parmetros de Servicio. ................ 11
MigracionManualCpe1000 4Motion 4
1 Alcance El presente documento explica como migrar un CPE1000 (RD2) en forma local al software 4Motion y con las configuraciones necesarias para asociarse a la radio base y obtener servicio.
2 Antecedentes. Por diferentes motives puede pasar que algunos CPEs no queden migrados en software y/o configuracin durante la migracin de la red Bmax FDD a 4Motion. Durante dicha migracin se realizan distintitas tareas remotas de actualizacin de software y preparacin de configuracin, algunas de estas tareas para algunos CPEs pueden fracasar por distintos motivos tales como: el CPE no estaba active durante el cambio de configuracin, el CPE no tomo algunos de los cambios, el CPE no estaba instalado, etc. En estas ocasiones es necesaria la visita tcnica a donde est instalado el CPE para solucionar el problema manualmente, ya que luego de la migracin de la radio base en donde est asociado el CPE va a quedar sin servicio.
MigracionManualCpe1000 4Motion 5
3 Requerimientos
3.1.1 PC local. Se requiere en sitio una PC local equipada con: Placa de red Ethernet 10/100. Software de navegacin Web, tales como Internet Explorer, Mozilla Firefox, Google Chrome, etc. Software de TFTP server. Software cliente telnet.
3.1.2 Cables Cable UTP cat 5.
4 Conexin local al CPE.
4.1.1 Configurar la direccion IP Configurar la tarjeta de red con la IP 192.168.254.220, mascara de red 255.255.255.0 4.1.2 Acceso Web. Utilizando el navegador Web acceder a travs del URL: http://192.168.254.251. Acceder utilizando el usuario installer con el password installer. 4.1.3 Acceso Telnet. Se puede acceder por telnet a travs de la direccin local del CPE: 192.168.254.251. Acceder utilizando el usuario installer con el password installer.
MigracionManualCpe1000 4Motion 6
4.1.4 Verificaciones. Lo primero a verificar es que el CPE tengo cargado el software de 4Motion. Para esto observamos en el men unit control las 2 versiones de software que tiene cargada la unidad. En caso de que alguna de las versiones sea la versin 2.5.1.3001 entonces el software est cargado en el CPE y debemos continuar con el paso de configuracin. En caso contrario, continuar con el procedimiento de actualizacin de software siguiente.
MigracionManualCpe1000 4Motion 7 5 Actualizacin de software del CPE. Este procedimiento se debe de seguir en caso en que el CPE NO tenga en alguno de sus bancos de memoria la versin 2.5.1.3001. Para cargar el software de 4Motion es imprescindible que la unidad este corriendo desde el banco main con la versin de software 3.8.1.642. En caso en que la unidad no tenga en alguno de sus bancos de memoria la versin 3.8.1.642 es necesario cargarlo, booteralo desde la Shadow y luego ponerlo como Main esta versin 3.8.1.642 primero para en un segundo paso cargar la versin de software de 4Motion 2.5.1.3001. 5.1.1 Carga de software Para cargar un Nuevo software en el CPE1000 es necesario que este no est corriendo de su banco main. A travs de la interface Web, ir al men Unit Control -> Sw versin Control. En la opcin browse debemos de buscar el archivo de software que queremos cargar. En la opcin TFTP Server IP Address debemos poner la direccin IP de la PC: 192.168.254.220 En este momento hay que correr el servidor TFTP en la PC que tenga configurado el directorio donde busca los archivos requeridos en donde este la versin de software del CPE a cargar. Presionar SW Download.
MigracionManualCpe1000 4Motion 8
Monitorear en el TFTP server para observar que se est enviando el archivo, la carga de los archivos demora de 1 a 8 minutos. Nunca desconectar el CPE durante el proceso. Se tiene que observar en la Web un mensaje:
Cuando se carga el software 2.5.1.3001 es necesario esperar 5 minutos luego del mensaje TFTP Succeeded ya que el proceso de actualizacin continua, si este se monitorea a travs de telnet se observaran estos mensajes: TFTP succeded sw type : 16E split. Split version recognized download Split version succeeded. Verificar que el software cargado aparece en la versin shadow del CPE, en caso contrario repetir el procedimiento de carga. Es normal que a veces se requiera repetir esta operacin.
Una vez cargado el software se necesita resetear el CPE para que arranque con esta versin, para esto seleccionar la opcin Run From Shadow.
Esto causa que el CPE se resetee y arranque con la versin cargada.
MigracionManualCpe1000 4Motion 9
6 Configuracin del CPE para 4Motion Este procedimiento se debe de seguir en caso en que el CPE este corriendo la versin de software de 4Motion: 2.5.1.3001.
6.1.1 Configuracin de parmetros BSID. Acceder por Web e ir al menu Configuration-Base Station Configurar el BST y preferred BST con el BSID del sector donde se necesita asociar el CPE. Configurar BST Mask y Preferred BST Mask en 255.255.255.255.255.255. Configurar el mobility mode en Nomadic.
MigracionManualCpe1000 4Motion 10
6.1.2 Configuracin de parmetros de Radio. Configurar en el menu Configuration-> Radio bandwith en 7Mhz Configurar en el menu Configuration-> Scanning los siguientes valores: Star Freq = 3478.500 Mhz Stop Freq = 3499.500 Mhz Main Step = 1000 Khz. Intermediate steps: solamente marcar start. Frecuencias discretas: F1: 3478.500 F2: 3479.500 F3: 3485.500 F4: 3487.500 F5: 3495.500 F6: 3578.500 F7: 3579.500 F8: 3585.500 F9: 3587.500 F10: 3595.500 Presionar Update y luego Update Scan Table
MigracionManualCpe1000 4Motion 11
6.1.3 Configuracin de parmetros de Servicio. Estos parmetros normalmente estn precargados en el sistema de gestin StarACS (para CPEs que son migrados) y son provisionados en el CPE unas ves que este se asocia en forma automtica. En caso de necesidad se pueden configurar localmente en el CPE.
Acceder por Telnet al CPE En caso de que en aparezca el men 8 Service Parameters IPCS ingresar a men 2 Service Operation Mode y configurar la opcin 1 Ethernet CS mode. Luego de esto resetiar el CPE por algn mtodo por ejemplo en el men 2 Unit Control opcin 2 Reset Unit.