Vous êtes sur la page 1sur 4

Digital Features

The TS981 digital control panel allows


easy and rapid setting of limit switch
positions and door parameters from
ground level.
The features of the TS981 include a
smoke curtain/ smoke retaining position,
dedicated traffic light relays with 2-way
traffic control option, monitored safety
devices for high level anti-trapping and
two additional relay outputs for turning
on/off or interlocking other equipment.
The airlock module interlocks two
doors. The second door is automatically
opened 0 10 seconds, adjustable,
after the first door closes removing the
need for Open push buttons or sensors
within the airlock. The control panel also
has a status-monitoring module
allowing door status information to be
displayed at remote locations.
As with the other Guthrie Douglas
controls the TS981 includes as standard,
a programmable door maintenance
indicator. This allows the installer to set
a maintenance interval to suit the door
and its application of between 1000 to
99000 operations on completion of
which the control will tell the customer
that the door needs servicing.
Simplifying on-site
installation
The TS981 has simple plug-in connections
for the motor, digital limits, safety edge,
slack wire and pass door switches.
The motor and digital limits are connected
to the TS981 by a protected cable
available in 3, 5, 7, 9 and 13m lengths.
The TS981 automatically recognises three
types of safety edge: Normally closed
with 1K2 resistor (air switch, tested
every cycle), Normally open with 8K2
resistor (contract strip, monitored) and
the Fraba optical type.
Enclosure Enhancements
The new purpose built enclosure with a
fully protected printed-circuit board
meets the IP65 class for dust and
moisture protection. The enclosure has
pre-drilled entries and flexible feet for
mounting on uneven surfaces and
incorporates open, close and stop
buttons with the provision for installing
a key switch and/or latching stop button
if required.
Meeting the Standards
The TS981 meets the requirements of
BS EN 12453 and the introduction of a
programmable maintenance indicator
further enhances the safety regime for
the user.
According to whether the intended
users are trained or not and whether the
door is in a public area or not,
determines the degree of safety
required.
TS981
Digital Control System for Industrial Doors
I
N
D
U
S
T
R
I
A
L

A
C
C
E
S
S
Limit switch setting from ground level
Digital display of door status and/or fault
diagnostic
Operations cycle counter (non re-settable)
Programmable Door Maintenance
Indicator
Dedicated traffic light relay options
Two additonal relay output functions
Monitored safety devices for high level
anti-trapping
Airlock module for interlocking doors
Door status monitoring of modules at
remote locations
Certified to BS EN 12453
www.guthriedouglas.com
Door User Control Unit Obligatory Function
Accessories
Trained user only TS981 N/A Impulse Open
Not in a public area In sight of door Hold to run Close
Trained user TS981 Key Switch Impulse Open
In a public area In sight of door on/off Hold to run Close
Trained user TS981 Safety Edge Impulse Open
In a public area In sight of door Impulse Closed
General Public TS981 Safety Edge Impulse Open
In/out of sight of door and Photo Beam Impulse Closed
Note: Doors that can lift a person require additional safety devices against anti-trapping at high level.
Control Panel TS981
Supply
3 x 400V/N/PE
3 x 400V/PE
1 x 230V/N/PE
Fire Alarm
system
230V
External
supply
2 potentially
free
contacts
Airlock
module
Status
monitoring
module
Control Panel TS981
Dedicated traffic light relays can be configured as
follows:
One-way mode: green when the door is open,
red when the door is moving, and red selectable
on/off when the door is closed.
Two-way mode: when the door is only wide
enough for one vehicle the traffic lights control
entry and exit. However the direction in which the
vehicle is approaching is required through
terminals X5, X15 and X7, X17 (e.g. with loops).
Extended green light period, forewarning period
of 10 seconds, gateway evacuation period and
red light operation when the door is closed.
Connection for high level anti-trapping safety
devices:
Normally closed contact through beam photo
beam which is tested before each movement.
Other devices available include: normally closed
contact safety edge and normally open contact
safety edge.
Plug-in connection for airlock modules to
interlock two doors. The second door is
automatically opened 0 10 seconds, adjustable,
after the first door closes removing the need for
Open push buttons or sensors within the airlock.
The smoke curtain or smoke retaining function
allows the door to be closed to a position of 2.5m
above floor level when activated by the fire alarm
system.
The control panel can interface with the DU & FI
digitally controlled variable speed direct inverter
drive units, allowing the opening/closing speed
and acceleration/deceleration ramps to be
adjusted. The opening and closing speeds are
displayed in RPM.
Connection for reflective 6m and 9m or 20m
through-beam photo beams, which stops and
reopens the door if the beam is obstructed whilst
the door is closing.
Door overload monitoring function only for use
on sectional doors. The overload monitoring
function is in addition to the high level anti-
trapping devices, but not to replace them.
Limit switch and door parameter setting from
ground level.
Programmable door maintenance indicator with
three response modes including the option for
the service due function to be overridden once
to allow for a further 500 cycles.
Last 2 faults memorised.
Connection for loop detector.
The TS981 control incorporates all of these features:
Consult our technical department for further information on
the Airlock module.
I
N
D
U
S
T
R
I
A
L

A
C
C
E
S
S
Accessories for use with Control Panels
Guthrie Douglas Limited
Unit 1, Titan Business Centre,
Spartan Close,
Warwick, UK CV34 6RR
Tel: (+44) 01926 452 452
Fax: (+44) 01926 336 417
E-mail: sales@guthriedouglas.com
Assessed to ISO 9001: 2008
Certificate No 193


1
1
.
1
0
GE301955*
Traffic indicator assembly, red
and green
PES135/6*
Polarised reflex photo-beam
(<6m range)
PES135/9
Polarised reflex photo-beam
(<9m range)
PES132/20
Through-beam sender and
receiver (<20m range)
VR/R2E
Receiver 433MHz, 2 Channel
rolling code
VR/TF2E*
Key-fob transmitter 2 Channel
433MHz
VR/TF4E*
Key-fob transmitter 4 Channel
433MHz
VR/TW4E*
Transmitter 4 Channel
433MHz
VR/60733*
Vehicle mounted transmitter,
1 Channel 433MHz
VR/60734
Vehicle mounted transmitter,
2 Channel 433MHz
KSR4P
Fraba safety edge kit (<6m)
KSR4P/10
Fraba safety edge kit (<10m)
KSR6P*
Wireless Safety Edge Kit (<6m)
KSR6P/10
Wireless Safety Edge Kit (<10m)
GF10045
Edge profile, roller shutters
GF10050
Bump stop for roller shutters
GF10085
Edge profile, sectional doors
GF10095
Bump stop for sectional doors
GF10100
Edge profile, high speed doors
GF10110
Bump stop for high speed
doors
GF40594 Mounting rail 3m
GF/AC2001 Draw wire (7m)
GE46390*
Pull switch, for wall or ceiling
mounting with 2.5m chain
ELS 145FH
Shoot bolt interlock switch
GE34615*
Panel mounted latching stop
button
GE34616*
Panel mounted key switch
JAPZ4-IR
Remote Key Switch with 3
push buttons
IFALCONXL
Industrial motion sensor
(3.5m high)
IFALCON*
Industrial motion sensor
(<7m high)
ICONDOR
Motion and presence sensor
(<6m high)
IREMOTE*
Remote control setting
*ILLUSTRATED
Company Reg No. 1489927 V.A.T. Reg No. GB 307 3656 62
GE23029/030
Protected cable (3m)
GE23029/050
Protected cable (5m)
GE23029/070
Protected cable (7m)
GE23029/090
Protected cable (9m)
GE23029/130
Protected cable (13m)

Vous aimerez peut-être aussi