Vous êtes sur la page 1sur 40

RAKCAB

RAKCAB

RAS AL KHAIMAH Cables FZC


...quality you can see

About us...
Ras Al Khaimah Cables FZC. is established in Ras-Al-Khaimah, U.A.E.
The manufacturing facility is located at Industrial Park in the RAK
Free Trade Zone located 130kms from Dubai. It utilizes advanced
cable making equipment and technology to produce specialized range
of cables for use in various applications.
The company is formed by leading technocrats having wide
experience in manufacturing and marketing of various kinds of cables
& related products in the Telecom & Electrical industry. The
promoters have a strong presence in the U.A.E

PRODUCT RANGE
Ras Al Khaimah Cables wide range of products includes:
- Building Construction
Wires and Wiring Cables, Indoor Telecom Cables, Networking
Cables and solutions
- Industry
Control & Instrumentation Cables
- Infrastructure
Low Voltage Power Cables, External Telecom Cables

QUALITY STATEMENT
Ras Al Khaimah Cables has an objective of providing high
quality products & services to its customers at a right
price through competitive approach.
Quality is our competency, which is achieved by our
qualified & dedicated staff to ensure product excellence.

RAKCAB

All our products comply with the latest British &


International standards.

DISTRIBUTION NETWORK
The company is marketing their range of products under the brand name RAKCAB throughout the GCC, Middle
East & Africa, and CIS countries and has a wide distribution network in the region. Taking advantage of the
proximity to the sea port and developed highway network, we have one of the quickest delivery schedules in the
cabling industry for complex and standard cables.

ENVIRONMENTAL POLICIES
We at Ras Al Khaimah Cables maintain a safe & healthy working environment for our employees and ensure
compliance to changing business practices in health and safety worldwide. We are committed to environmentally
conscious operations & products.

Contents
ELECTRICAL WIRES & CABLES

Building Wires
Single Core PVC Insulated Wires..............................................................................................................................................
BS6004 | H07V-U/R
Bare Copper & Yellow/Green Earthing Conductor..............................................................................................................
BS6004 | H07V-U/R
Single Core PVC Insulated & Sheathed Wires .......................................................................................................................
BS6004/BS6346
Single Core XLPE Insulated, PVC Sheathed (Unarmoured) ................................................................................................
BS6346/BS7889
LSF Wiring Cables.........................................................................................................................................................................
BS7211 | H07Z-U/R

Panel Wires
Heat Resisting PVC Insulated Panel Wires .............................................................................................................................
BS6231 | H07V2-K

Multicore Flexible Cables


Multicore PVC Insulated & Sheathed Flexible Cables...........................................................................................................
BS6500/BS7919 | H05VV-F
Heat Resisting Multicore PVC Insulated & Sheathed Flexible Cables...............................................................................
BS6500/BS7919 | H05V2V2-F
Flexible Control Cables ...............................................................................................................................................................
BS6500/BS7919 | H05VV5-F
PVC Insulated Twin Flexible Cables ..........................................................................................................................................
BS6500
Flat Wiring Cables PVC Insulated & Sheathed .......................................................................................................................
BS6004

Low Voltage Power Cables


CU / XLPE / SWA / PVC Low Voltage Power Cables ..........................................................................................................
BS5467
Current Ratings & Voltage Drop ...............................................................................................................................................
Auxiliary Cables 600/1000V.......................................................................................................................................................
BS5467

6
7
8
9
10

11

12
14
16
18
18

20
23
25

Internal Telephone Cables


Type CW 1308 0.5mm.................................................................................................................................................................

28

External Telephone Cables


Type Unit Twin 0.5mm .................................................................................................................................................................

29

Type Unit Twin 0.63mm...............................................................................................................................................................

30

Type Unit Twin 0.9mm .................................................................................................................................................................

31

Direct Burial Armoured Cable...................................................................................................................................................

32

Type ELAKY 0.65mm....................................................................................................................................................................

33

Drop Wires
Drop Wires 0.81mm ..................................................................................................................................................................

34

Drop Wires 0.5mm ....................................................................................................................................................................

34

Jumper Wires & Equipment Wires


Jumper Wires & Equipment Wires ...........................................................................................................................................

35

Data Cables
SUPERLAN Cat 5E........................................................................................................................................................................

36

SUPERLAN Cat 6..........................................................................................................................................................................

37

Instrumentation Cables
Instrumentation Cables................................................................................................................................................................

38

RAKCAB

TELECOMMUNICATION, DATA & INSTRUMENTATION CABLES

ELECTRICAL
WIRES & CABLES

Single Core PVC Insulated Wires

APPLICATION
These cables are intended for drawing into trunking and conduit and are suitable for use
in electrical installations such as power, lighting, appliances and switchgear wiring.

HARMONISED CODE
- 0.75mm2 & 1.0mm2 solid conductor wire
H05V-U
- 1.5mm2 & 2.5mm2 solid conductor wire
H07V-U
- 1.5mm2 to 120mm2 stranded conductor wire H07V-R

CONSTRUCTION
Reference
: 6491X or 6491X HR*
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655
* PVC Type TI 3 HR to BS7655

STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green, Brown, Grey
Other colours available on request

PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m
- Customised lengths available on request

TECHNICAL DATA
Max. Operating Temperature : 70OC/ *105OC
Rated Voltage
: 450/750V (300/500V for 0.75mm2 & 1.0mm2)
Standards
: Generally to BS6004

Nominal
CrossSectional
Area

Conductor
Number of Diameter of
Strands
Strand

RAKCAB

(mm2)

0.75
1.00
1.50
1.50
2.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

1
1
1
7
1
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
91
91

Max.
Resistance
at 20OC

Radial
Thickness
of Insulation

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(kg/km)

(A)

0.98
1.13
1.38
0.53
1.78
0.67
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50
2.85
2.65
2.97

24.50
18.10
12.10
12.10
7.410
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283

0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2
2.6
2.8
2.8

2.40
2.60
3.20
3.30
3.90
4.00
4.60
5.20
6.70
7.80
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60
33.20
36.90
41.10

11
14
21
22
32
35
50
71
120
180
280
380
510
710
970
1200
1480
1900
2480
3100
3940
5000
6350

10
12
16
16
21
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611

Product Code

SCO0.75
SCO1.0
SCO1.5
SC1.5
SCO2.5
SC2.5
SC4.0
SC6.0
SC10.0
SC16.0
SC25.0
SC35.0
SC50.0
SC70.0
SC95.0
SC120.0
SC150.0
SC185.0
SC240.0
SC300.0
SC400.0
SC500.0
SC630.0

Note:
* 0.75mm2 x single core HR PVC insulated 105OC available. Suitable for flourescent lights wiring.

Bare Copper & Yellow/Green Earthing Conductor

APPLICATION
These cables are intended for use in electrical installations for earthing purpose

CONSTRUCTION
Conductor
: Stranded plain copper class 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655 for Yellow/Green earth wire only

PACKAGING
- All sizes can be supplied in non-returnable ply/wooden reels of 500m and 1000m
- Customised lengths available on request

TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 450/750V
Standards
: BS6004

BARE COPPER
Nominal
CrossSectional
Area

Conductor
Number of
Diameter of
Strands
Strand

(mm2)

10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0

7
7
7
7
19
19
19
37
37
37
61
61

Max.
Resistance at
20OC

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(kg/km)

(A)

1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.27
2.52
2.25
2.50

1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601

4.05
5.10
6.42
7.56
9.15
10.85
12.60
14.28
15.89
17.64
15.75
22.50

88.90
142.24
222.25
311.15
444.50
622.30
844.55
1066.80
1333.50
1644.65
2133.60
2667.00

50
68
89
110
134
171
207
239
262
296
346
394

Product Code

BC10.0
BC16.0
BC25.0
BC35.0
BC50.0
BC70.0
BC95.0
BC120.0
BC150.0
BC185.0
BC240.0
BC300.0

YELLOW/GREEN EARTH WIRE


Conductor
Number of Diameter of
Strands
Strand

(mm2)

10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0

7
7
7
7
19
19
19
37
37
37
61
61

Max.
Resistance
at 20OC

Radial
Thickness
of Insulation

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(kg/km)

(A)

1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50

1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601

1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2

6.70
7.10
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60

110
171
260
350
480
680
930
1160
1430
1740
2270
2840

50
68
89
110
134
171
207
239
262
296
346
394

Product Code

SC10.0YG
SC16.0YG
SC25.0YG
SC35.0YG
SC50.0YG
SC70.0YG
SC95.0YG
SC120.0YG
SC150.0YG
SC185.0YG
SC240.0YG
SC300.0YG

RAKCAB

Nominal
CrossSectional
Area

Single Core PVC Insulated & Sheathed Wires

APPLICATION
These cables are intended for surface wiring where there is little risk of mechanical
damage and are suitable for use in electrical installations such as power and lighting.

CONSTRUCTION
Reference
: 6181Y
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655
Sheath
: PVC Type TM 1 or Type 6 to BS7655

STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green, Brown, Grey
Other colours available on request

PACKAGING
- Sizes 1.5mm2 to 4mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m

TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 1.0mm2 to 35.0mm2 - 300/500V
50.0mm2 and above - 600/1000V
Standards
: 1.0mm2 to 35.0mm2 - BS6004
50.0mm2 and above - BS6346

Nominal
CrossSectional
Area

Conductor
Number Diameter
of Strands of Strand

(mm2)

RAKCAB

1.00
1.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

1
1
1
7
7
7
7
7
7
19
19
19
37
37
37
37
61
61
91
91

Max.
Resistance
at 20OC

Radial
Thickness
of
Insulation

Radial
Thickness
of
Sheath

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(mm)

(kg/km)

(A)

1.13
1.38
1.78
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.27
2.52
2.87
2.50
2.85
2.65
2.97

18.10
12.10
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283

0.60
0.70
0.80
0.80
0.80
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.00
2.20
2.20
2.20
2.50

0.80
0.80
0.80
0.90
0.90
0.90
1.00
1.10
1.10
1.40
1.40
1.50
1.50
1.80
2.00
2.00
2.20
2.20
2.20
2.50

4.50
4.90
5.80
6.80
7.40
8.80
10.50
12.50
13.50
14.75
16.45
18.80
20.48
23.09
25.64
28.09
31.03
35.00
38.50
43.50

26
35
49
74
97
147
218
327
426
594
793
1062
1307
1646
2031
2563
3195
4156
5114
6459

12
16
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611

Product Code

SCS1.0
SCS1.5
SCS2.5
SCS4.0
SCS6.0
SCS10.0
SCS16.0
SCS25.0
SCS35.0
SCS50.0
SCS70.0
SCS95.0
SCS120.0
SCS150.0
SCS185.0
SCS240.0
SCS300.0
SCS400.0
SCS500.0
SCS630.0

Single Core Cable: XLPE Insulated, PVC Sheathed (Unarmoured)


APPLICATION
These cables are intended for surface wiring where there is little risk of mechanical
damage and for laying into trunking or conduit etc., are suitable for use in electrical
installations such as power and lighting.

CONSTRUCTION
Reference
: 6181XY
Conductor
: Stranded plain copper conductor class 2 to BS6360/IEC60228-1
Insulation
: XLPE
Sheath
: PVC Sheathed

STANDARD COLOURS
Cores
: Brown or Blue
Sheath
: Black. Other colours available on request

PACKAGING
All sizes can be supplied in non-returnable wooden drums of 500m/1000m

TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS7889, BS6346, IEC60502

Nominal
CrossSection
Area

Copper Conductor
Number Diameter
of Strands of Strand

(mm2)

50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

19
19
19
37
37
37
37
61
61
91
91

Max.
Resistance at
20OC

Radial
Thickness
of
Insulation

Radial
Thickness
of Sheath

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(mm)

(kg/km)

(A)

1.83
2.17
2.52
2.04
2.27
2.52
2.87
2.50
2.89
2.64
2.97

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283

1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40

1.40
1.40
1.50
1.50
1.60
1.60
1.70
1.80
1.90
2.00
2.20

14.00
15.85
17.80
19.80
22.00
24.70
27.70
30.60
34.20
38.00
42.90

541
749
1000
1241
1523
1942
2514
3125
3967
5063
6491

134
171
207
239
262
296
346
394
467
533
611

Product Code

SCSX50.0
SCSX70.0
SCSX95.0
SCSX120.0
SCSX150.0
SCSX185.0
SCSX240.0
SCSX300.0
SCSX400.0
SCSX500.0
SCSX630.0

RAKCAB

LSF Wiring Cables

APPLICATION
Industrial wiring installations where smoke and acid gas emission would pose a major
hazard in the event of fire. These cables are intended for drawing into trunking and
conduit and are suitable for use in electrical installations such as power, lighting,
appliances, switchgear and controlgear, which are to be used in higher temperature
zones.

HARMONISED CODE
- 0.75mm2 & 1.0mm2 solid conductor wire
- 1.5mm2 & 2.5mm2 solid conductor wire
- 1.5mm2 to 120mm2 stranded conductor wire

CONSTRUCTION
Reference
: 6491B
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: Thermosetting, low smoke zero halogen

STANDARD COLOURS
Colours
: Black, Blue, Red, Yellow, Green/Yellow, Grey
Other colours available on request.

PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m
- Customised lengths available on request

TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 450/750V (300/500V for 0.75mm2 & 1.0mm2)
Standards
: Generally to BS7211

RAKCAB

Nominal
CrossSectional
Area
(mm2)

10

H05Z-U
H07Z-U
H07Z-R

0.75
1.00
1.50
1.50
2.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

Conductor
Number of Diameter of
Strands
Strand

1
1
1
7
1
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
91
91

Max.
Resistance
at 20OC

Radial
Thickness
of Insulation

Approx.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(kg/km)

(A)

0.98
1.13
1.38
0.53
1.78
0.67
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50
2.85
2.65
2.97

24.50
18.10
12.10
12.10
7.410
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283

0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2
2.6
2.8
2.8

2.40
2.60
3.20
3.30
3.90
4.00
4.60
5.20
6.70
7.80
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60
33.20
36.90
41.10

11
14
21
22
32
35
50
71
120
180
280
380
510
710
970
1200
1480
1900
2480
3100
3940
5000
6350

10
12
16
16
21
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611

Product Code

SCLO0.75
SCLO1.0
SCLO1.5
SCL1.5
SCLO2.5
SCL2.5
SCL4.0
SCL6.0
SCL10.0
SCL16.0
SCL25.0
SCL35.0
SCL50.0
SCL70.0
SCL95.0
SCL120.0
SCL150.0
SCL185.0
SCL240.0
SCL300.0
SCL400.0
SCL500.0
SCL630.0

Heat Resisting PVC Insulated Panel Wires

APPLICATION
These cables are intended for use in fixed installations such as power, lighting, appliances
and switchgear & control panel wiring.

HARMONISED CODE
- 0.5mm2 to 1.0mm2 wire
- 1.5mm2 & 300mm2 stranded conductor wire

H05V2-K
H07V2-K

CONSTRUCTION
Reference
: 2491X HR
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
(Tinned copper conductor available on request)
Insulation
: PVC Type TI 3 to BS7655

STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green
Grey, White, Orange, Brown, Violet, Pink, Turquoise
Other colours available on request

PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden drums of 500m and 1000m

TECHNICAL DATA
Max. Operating Temperature : Upto 105OC
Rated Voltage
: 600/1000V
Standards
: BS6231

Nominal
CrossSectional
Area

Conductor
Number of Diameter of
Strands
Strand

(mm2)

0.50
0.75
1.00
1.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0

16
24
32
30
50
56
84
80
126
196
276
396
360
475
608
750
925
1221

Max.
Resistance
at 20OC

Radial
Thickness
of Insulation

Max
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(mm)

(/km)

(mm)

(mm)

(kg/km)

(A)

0.20
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50

39.00
26.00
19.50
13.30
7.980
4.950
3.300
1.910
1.210
0.780
0.560
0.390
0.270
0.210
0.160
0.124
0.0991
0.0754

0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2

3.00
3.10
3.30
3.60
4.10
4.80
5.30
7.20
9.00
11.5
12.50
15.40
17.50
19.20
21.20
23.90
25.90
28.90

13
15
18
24
35
51
70
118
180
280
375
537
728
977
1215
1521
1870
2410

8
10
12
16
21
28
36
50
68
89
110
134
171
207
239
262
296
346

Product Code

PW0.5
PW0.75
PW1.0
PW1.5
PW2.5
PW4.0
PW6.0
PW10.0
PW16.0
PW25.0
PW35.0
PW50.0
PW70.0
PW95.0
PW120.0
PW150.0
PW185.0
PW240.0

RAKCAB

11

Multicore PVC Insulated & Sheathed Flexible Cables

APPLICATION
General purpose indoors or outdoors in dry or damp situations. Portable tools, washing
machines, vacuum cleaners, lawn mowers and light domestic applications.

HARMONISED CODE
H05VV-F

CONSTRUCTION
Reference
: 0.5mm2 to 4mm2 - 318-Y and 6.0mm2 to 25mm2 - 638-Y
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI 2 to BS7655
Lay-up
: Cores are twisted
Sheath
: PVC Type TM 2 to BS7655

COLOUR CODING
Cores
: 2-core- Brown, Blue
3-core- Brown, Blue, Green/Yellow
4-core- Brown, Black, Grey, Green/Yellow
5-core- Brown, Black, Grey, Blue, Green/Yellow
Sheath

: White, Black, Grey


Other colours available on request

PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m or non-returnable wooden
drums of 500m and 1000m

TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 0.5mm2 to 4mm2 - 300/500V
6.0mm2 to 25mm2 - 600/1000V
Standards
: BS6500/BS7919

RAKCAB

contd...

12

Multicore PVC Insulated & Sheathed Flexible Cables


Conductor
Nominal
CrossSectional
Area

Number
of
Strands

(mm2)

Radial
Thickness
of
Insulation

Radial
Thickness
of Sheath

Max.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(/km)

(mm)

(mm)

(mm)

(kg/km)

(A)

FX2C0.5

Diameter
of Strand

Max.
Resistance
at 20OC

(mm)

Product Code

0.5

16

0.20

39.00

0.6

0.8

6.8

52

0.75

24

0.20

26.00

0.6

0.8

7.2

63

FX2C0.75

1.0

32

0.20

19.50

0.6

0.8

7.5

73

14

FX2C1.0

1.5

30

0.25

13.30

0.7

0.8

8.6

95

18

FX2C1.5

2.5

50

0.25

7.98

0.8

1.0

10.6

145

24

FX2C2.5

4.0

56

0.30

4.95

0.8

1.1

11.8

190

32

FX2C4.0

6.0

84

0.30

3.30

0.8

1.2

13.1

256

42

FX2C6.0

10.0

80

0.40

1.91

1.0

1.4

16.1

397

55

FX2C10.0

16.0

126

0.40

1.21

1.0

1.4

18.5

596

75

FX2C16.0

25.0

196

0.40

0.78

1.2

1.4

21.6

956

100

FX2C25.0

0.5

16

0.20

39.00

0.6

0.8

7.2

60

FX3C0.5

0.75

24

0.20

26.00

0.6

0.8

7.5

74

FX3C0.75

1.0

32

0.20

19.50

0.6

0.8

8.0

86

14

FX3C1.0

1.5

30

0.25

13.30

0.7

0.9

9.4

120

18

FX3C1.5

2.5

50

0.25

7.98

0.8

1.1

11.4

180

24

FX3C2.5

4.0

56

0.30

4.95

0.8

1.2

12.6

236

32

FX3C4.0

6.0

84

0.30

3.30

0.8

1.4

14.2

344

42

FX3C6.0

10.0

80

0.40

1.91

1.0

1.4

17.1

489

55

FX3C10.0

16.0

126

0.40

1.21

1.0

1.4

19.5

724

75

FX3C16.0

25.0

196

0.40

0.78

1.2

1.6

23.5

1154

100

FX3C25.0

0.5

16

0.20

39.00

0.6

0.8

7.9

72

FX4C0.5

0.75

24

0.20

26.00

0.6

0.8

8.3

83

FX4C0.75

1.0

32

0.20

19.50

0.6

0.9

9.0

101

14

FX4C1.0

1.5

30

0.25

13.30

0.7

1.0

10.5

141

18

FX4C1.5

2.5

50

0.25

7.98

0.8

1.1

12.5

214

24

FX4C2.5

4.0

56

0.30

4.95

0.8

1.4

14.0

286

32

FX4C4.0

6.0

84

0.30

3.30

0.8

1.4

15.5

411

42

FX4C6.0

10.0

80

0.40

1.91

1.0

1.4

18.6

637

55

FX4C10.0

16.0

126

0.40

1.21

1.0

1.4

21.5

988

75

FX4C16.0

25.0

196

0.40

0.78

1.2

1.6

25.7

1453

100

FX4C25.0

0.5

16

0.20

39.00

0.6

0.9

8.6

89

FX5C0.5

0.75

24

0.20

26.00

0.6

0.9

9.2

113

FX5C0.75

1.0

32

0.20

19.50

0.6

0.9

9.6

130

14

FX5C1.0

1.5

30

0.25

13.30

0.7

1.0

11.2

171

18

FX5C1.5

2.5

50

0.25

7.98

0.8

1.2

13.4

265

24

FX5C2.5

4.0

56

0.30

4.95

0.8

1.4

15.4

353

32

FX5C4.0

6.0

84

0.30

3.30

0.8

1.4

16.5

506

42

FX5C6.0

10.0

80

0.40

1.91

1.0

1.4

20.6

815

55

FX5C10.0

16.0

126

0.40

1.21

1.0

1.6

24.0

1202

75

FX5C16.0

25.0

196

0.40

0.78

1.2

1.6

28.6

1818

100

FX5C25.0

RAKCAB

No. of
Cores

13

Heat Resisting Multicore PVC Insulated & Sheathed Flexible Cables

APPLICATION
General purpose, heat resisting, indoors or outdoors in dry or damp situations. Portable
tools, washing machines, vacuum cleaners, lawn mowers and light domestic applications,
especially in higher temperature zones.

HARMONISED CODE
H05V2V2-F

CONSTRUCTION
Reference
: 0.5mm2 to 4mm2 - 309-Y
Conductor
: Flexible plain copper class 5 to BS6360
Insulation
: PVC Type TI 3 to BS7655
Lay-up
: Cores are twisted
Sheath
: PVC Type TM 3 to BS7655

COLOUR CODING
Cores
: 2-core- Brown, Blue
3-core- Brown, Blue, Green/Yellow
4-core- Brown, Black, Grey, Green/Yellow
5-core- Brown, Black, Grey, Blue, Green/Yellow
Sheath

: White, Black, Grey


Other colours available on request

PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m or non-returnable wooden
drums of 500m and 1000m

TECHNICAL DATA
Max. Operating Temperature : upto 105OC
Rated Voltage
: 0.5mm2 to 4mm2 - 300/500V
6.0mm2 to 25mm2 - 600/1000V
Standards
: BS6500/BS7919 (Previously BS6141)

RAKCAB

contd...

14

Heat Resisting Multicore PVC Insulated & Sheathed Flexible Cables


Conductor
Nominal
CrossSectional
Area

Number
of
Strands

(mm2)

Radial
Thickness
of
Insulation

Radial
Thickness
of Sheath

Max.
Overall
Diameter

Approx.
Nett
Weight

Approx.
Current
Carrying
Capacity

(/km)

(mm)

(mm)

(mm)

(kg/km)

(A)

FXHR2C0.5

Diameter
of Strand

Max.
Resistance
at 20OC

(mm)

Product Code

0.5

16

0.20

39.00

0.6

0.8

6.8

52

0.75

24

0.20

26.00

0.6

0.8

7.2

63

FXHR2C0.75

1.0

32

0.20

19.50

0.6

0.8

7.5

73

14

FXHR2C1.0

1.5

30

0.25

13.30

0.7

0.8

8.6

95

18

FXHR2C1.5

2.5

50

0.25

7.98

0.8

1.0

10.6

145

24

FXHR2C2.5

4.0

56

0.30

4.95

0.8

1.1

11.8

190

32

FXHR2C4.0

6.0

84

0.30

3.30

0.8

1.2

13.1

256

42

FXHR2C6.0

10.0

80

0.40

1.91

1.0

1.4

16.1

397

55

FXHR2C10.0

16.0

126

0.40

1.21

1.0

1.4

18.5

596

75

FXHR2C16.0

25.0

196

0.40

0.78

1.2

1.4

21.6

956

100

FXHR2C25.0

0.5

16

0.20

39.00

0.6

0.8

7.2

60

FXHR3C0.5

0.75

24

0.20

26.00

0.6

0.8

7.5

74

FXHR3C0.75

1.0

32

0.20

19.50

0.6

0.8

8.0

86

14

FXHR3C1.0

1.5

30

0.25

13.30

0.7

0.9

9.4

120

18

FXHR3C1.5

2.5

50

0.25

7.98

0.8

1.1

11.4

180

24

FXHR3C2.5

4.0

56

0.30

4.95

0.8

1.2

12.6

236

32

FXHR3C4.0

6.0

84

0.30

3.30

0.8

1.4

14.2

344

42

FXHR3C6.0

10.0

80

0.40

1.91

1.0

1.4

17.1

489

55

FXHR3C10.0

16.0

126

0.40

1.21

1.0

1.4

19.5

724

75

FXHR3C16.0

25.0

196

0.40

0.78

1.2

1.6

23.5

1154

100

FXHR3C25.0

0.5

16

0.20

39.00

0.6

0.8

7.9

72

FXHR4C0.5

0.75

24

0.20

26.00

0.6

0.8

8.3

83

FXHR4C0.75

1.0

32

0.20

19.50

0.6

0.9

9.0

101

14

FXHR4C1.0

1.5

30

0.25

13.30

0.7

1.0

10.5

141

18

FXHR4C1.5

2.5

50

0.25

7.98

0.8

1.1

12.5

214

24

FXHR4C2.5

4.0

56

0.30

4.95

0.8

1.4

14.0

286

32

FXHR4C4.0

6.0

84

0.30

3.30

0.8

1.4

15.5

411

42

FXHR4C6.0

10.0

80

0.40

1.91

1.0

1.4

18.6

637

55

FXHR4C10.0

16.0

126

0.40

1.21

1.0

1.4

21.5

988

75

FXHR4C16.0

25.0

196

0.40

0.78

1.2

1.6

25.7

1453

100

FXHR4C25.0

0.5

16

0.20

39.00

0.6

0.9

8.6

89

FXHR5C0.5

0.75

24

0.20

26.00

0.6

0.9

9.2

113

FXHR5C0.75

1.0

32

0.20

19.50

0.6

0.9

9.6

130

14

FXHR5C1.0

1.5

30

0.25

13.30

0.7

1.0

11.2

171

18

FXHR5C1.5

2.5

50

0.25

7.98

0.8

1.2

13.4

265

24

FXHR5C2.5

4.0

56

0.30

4.95

0.8

1.4

15.4

353

32

FXHR5C4.0

6.0

84

0.30

3.30

0.8

1.4

16.5

506

42

FXHR5C6.0

10.0

80

0.40

1.91

1.0

1.4

20.6

815

55

FXHR5C10.0

16.0

126

0.40

1.21

1.0

1.6

24.0

1202

75

FXHR5C16.0

25.0

196

0.40

0.78

1.2

1.6

28.6

1818

100

FXHR5C25.0

RAKCAB

No. of
Cores

15

Flexible Control Cables


APPLICATION
Suitable for use as signal and control cable for various industrial & engineering applications.

HARMONISED CODE
H05VV5-F

CONSTRUCTION
Conductor
: Flexible Plain Copper Class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI2 to BS7655
Lay-up
: Cores twisted together, if necessary, in several concentric layers
Sheath
: PVC Type TM5 to BS7655

STANDARD COLOURS
Colour Coding : Core identification by number coding in accordance with BSEN 50334 and
earth core coloured Green/Yellow
Sheath
: Generally Grey, other colours available on request

PACKAGING
All sizes can be supplied in non-returnable wooden drums of 500m & 1000m

TECHNICAL DATA
Max. Operating Temperature
Rated Voltage
No. of Cores
Specification

:
:
:
:

RAKCAB

70OC
300/500V
6 to 60
Generally to BS6500/BS7919

RAKCAB

contd...

16

Flexible Control Cables


PVC INSULATED PVC SHEATHED FLEXIBLE CONTROL CABLE
Conductor
Nominal
CrossSectional
Area

Number
of
Strands

(mm2)

Radial
Thickness
of
Insulation

Radial
Thickness
of Sheath

Max.
Overall
Diameter

Approx.
Nett
Weight

(/km)

(mm)

(mm)

(mm)

(kg/km)

Diameter
of Strand

Max.
Resistance
at 20OC

(mm)

Product Code

0.50

16

0.2

39

0.6

0.9

9.6

114

FC6C0.50

0.75

24

0.2

26

0.6

0.9

10.10

139

FC6C0.75

1.00

32

0.2

19.5

0.6

1.0

10.80

173

FC6C1.00

1.50

30

0.25

13.3

0.7

1.1

12.60

240

FC6C1.50

2.50

50

0.25

7.98

0.8

1.2

15.10

357

FC6C2.50

0.50

16

0.2

39

0.6

0.9

10.40

114

FC7C0.50

0.75

24

0.2

26

0.6

1.0

11.30

150

FC7C0.75

1.00

32

0.2

19.5

0.6

1.0

11.80

177

FC7C1.00

1.50

30

0.25

13.3

0.7

1.2

14.10

257

FC7C1.50

2.50

50

0.25

7.98

0.8

1.3

16.80

382

FC7C2.50

12

0.50

16

0.2

39

0.6

1.1

12.90

203

FC12C0.50

12

0.75

24

0.2

26

0.6

1.1

13.70

252

FC12C0.75

12

1.00

32

0.2

19.5

0.6

1.2

14.60

311

FC12C1.00

12

1.50

30

0.25

13.3

0.7

1.3

17.00

432

FC12C1.50

12

2.50

50

0.25

7.98

0.8

1.5

20.60

663

FC12C2.50

18

0.50

16

0.2

39

0.6

1.2

15.30

279

FC18C0.50

18

0.75

24

0.2

26

0.6

1.3

16.40

363

FC18C0.75

18

1.00

32

0.2

19.5

0.6

1.3

17.20

431

FC18C1.00

18

1.50

30

0.25

13.3

0.7

1.5

20.30

618

FC18C1.50

18

2.50

50

0.25

7.98

0.8

1.8

24.80

966

FC18C2.50

27

0.50

16

0.2

39

0.6

1.4

18.60

410

FC27C0.50

27

0.75

24

0.2

26

0.6

1.5

19.90

532

FC27C0.75

27

1.00

32

0.2

19.5

0.6

1.5

21.00

634

FC27C1.00

27

1.50

30

0.25

13.3

0.7

1.8

24.90

924

FC27C1.50

27

2.50

50

0.25

7.98

0.8

2.1

30.20

1430

FC27C2.50

36

0.50

16

0.2

39

0.6

1.5

20.90

516

FC36C0.50

36

0.75

24

0.2

26

0.6

1.6

22.40

679

FC36C0.75

36

1.00

32

0.2

19.5

0.6

1.7

23.80

824

FC36C1.00

36

1.50

30

0.25

13.3

0.7

2.0

28.20

1192

FC36C1.50

36

2.50

50

0.25

7.98

0.8

2.3

34.20

1841

FC36C2.50

48

0.50

16

0.2

39

0.6

1.7

24.30

690

FC48C0.50

48

0.75

24

0.2

26

0.6

1.8

25.90

895

FC48C0.75

48

1.00

32

0.2

19.5

0.6

1.9

27.60

1096

FC48C1.00

48

1.50

30

0.25

13.3

0.7

2.2

32.50

1576

FC48C1.50

48

2.50

50

0.25

7.98

0.8

2.4

39.10

2393

FC48C2.50

60

0.50

16

0.2

39

0.6

1.8

26.60

826

FC60C0.50

60

0.75

24

0.2

26

0.6

2.0

28.70

1098

FC60C0.75

60

1.00

32

0.2

19.5

0.6

2.1

30.50

1343

FC60C1.00

60

1.50

30

0.25

13.3

0.7

2.4

35.80

1923

FC60C1.50

60

2.50

50

0.25

7.98

0.8

2.4

42.60

2848

FC60C2.50

RAKCAB

No. of
Cores

17

PVC Insulated Twin Flexible Cables

APPLICATION
These cables are intended for fixed protected installation inside appliances and in or on
lighting fittings, door bells, spaeaker etc.

CONSTRUCTION
Reference
: 2812X
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI 2 to BS7655

STANDARD COLOURS
Available in White, Red-Black or transparent PVC. Other colours available on request

PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m/500m/1000m

TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 300V
Standards
: BS6500

Conductor
Nominal
CrossSectional
Area

Maximum
Diameter of
Wire

Max.
Resistance
at 20OC

Radial
Thickness of
Insulator

Max.
Overall
Diameter

Approx.
Nett
Weight

(mm2)

(mm)

(/km)

(mm)

(mm)

(kg/km)

2 x 0.5
2 x 0.75

0.20
0.20

39.00
26.00

0.8
0.8

3.0 x 6.0
3.2 x 6.4

22
28

Product Code

TW2C0.5
TW2C0.75

RAKCAB

Flat Wiring Cables PVC Insulated & Sheathed

18

APPLICATION
For domestic and industrial wiring. Suitable for surface wiring where there is little risk of
mechanical damage.

CONSTRUCTION
Reference
: Twin/three core flat- 619-Y, Twin/three core flat with earth- 624-Y
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 or Type 5 to BS6746
Sheath
: PVC Type 6 or 9 to BS6746

contd...

Flat Wiring Cables PVC Insulated & Sheathed

COLOUR CODING
Cores
: 2-core- Red, Black
3-core- Red, Yellow, White
As per New Harmonised code
2-core- Brown, Blue
3-core- Brown, Black, Grey
Sheath

: White, Grey
Other colours available on request

PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m/500m/1000m

TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 300/500V
Standards
: BS6004

Reference
Number

Conductor
Nominal
CrossSectional
Area

Number of
Strands

(mm2)

6192Y
TWIN
FLAT

6193Y
THREE
CORE
FLAT

6242Y
TWIN
FLAT
WITH
EARTH

6243Y
THREE
CORE
FLAT
WITH
EARTH

1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0

1
1
1
7
7
7
7
1
1
1
7
7
7
7
1
1
1
7
7
7
7
1
1
1
7
7
7
7

Diameter
of Strand

Radial
Thickness
of
Insulation

Radial
Thickness
of Sheath

Approx.
Overall
Diameter

Approx.
Nett
Weight

Earth
Continuity
Conductor
Cross
section

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm2)

1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70

0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0

0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3

4.7x7.4
5.4x8.4
6.2x9.8
7.2x11.5
8.0x13.0
9.6x16.0
11.0x18.5
4.7x9.8
5.4x11.5
6.2x13.5
7.2x16.5
8.0x18.0
9.6x22.5
11.0x26.5
4.7x8.6
5.4x9.6
6.2x11.5
7.2x13.0
8.0x15.0
9.6x19.0
11.0x22.5
4.7x11.0
5.4x12.5
6.2x14.5
7.2x18.0
8.0x20.0
9.6x25.5
11.0x29.5

53
70
105
150
205
320
470
76
100
150
225
300
480
695
68
85
120
175
240
390
560
91
115
170
250
340
540
790

1.0
1.0
1.5
1.5
2.5
4.0
6.0
1.0
1.0
1.5
1.5
2.5
4.0
6.0

Product Code

FLTO2C1.0
FLTO2C1.5
FLTO2C2.5
FLT2C4.0
FLT2C6.0
FLT2C10.0
FLT2C16.0
FLTO3C1.0
FLTO3C1.5
FLTO3C2.5
FLT3C4.0
FLT3C6.0
FLT3C10.0
FLT3C16.0
FLTO2CE1.0
FLTO2CE1.5
FLTO2CE2.5
FLT2CE4.0
FLT2CE6.0
FLT2CE10.0
FLT2CE16.0
FLTO3CE1.0
FLTO3CE1.5
FLTO3CE2.5
FLT3CE4.0
FLT3CE6.0
FLT3CE10.0
FLT3CE16.0

RAKCAB

19

CU / XLPE / SWA / PVC Low Voltage Power Cables

APPLICATION
Industrial wiring and mains distribution. Can be laid direct in the ground, or in ducts,
clipped to surface, on trays or in free air.

CONSTRUCTION
Conductor
: Single, Two, Three, Four and Five core cables. Stranded plain copper
conductors
Insulation
: XLPE insulated, cores laid up, extruded PVC bedding, galvanised steel
wire armoured (Aluminium wires for single cores) and PVC
sheathed.

STANDARD COLOURS
Cores
: Single-core- Red or Black
2-core- Red and Black
3-core- Red, Yellow and Blue
4-core- Red, Yellow, Blue and Black
5-core- Red, Yellow, Blue, Black and Green/Yellow
As per New Harmonised Code
Single-core- Brown or Blue
2-core- Brown and Blue
3-core- Brown, Black and Grey
4-core- Brown, Black Grey and Blue
5-core- Brown, Black, Grey, Green/Yellow and Blue
Sheath Colours : Black. Other colours available on request

MINIMUM BENDING RADIUS


6D circular conductors, 8D shaped conductors

TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS5467

RAKCAB

Single Core Cables - 600/1000V

20

Nominal
Area of the
Conductor

Thickness of
Insulation

Thickness
of Extruded
Bedding

Diameter of Thickness of
Armour Wire Outer Sheath

(mm2)

(mm)

(mm)

(mm)

50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
800.0
1000.0

1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8

0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4

0.90
1.25
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50

Approx
Overall
Diameter

Approx.
Nett
Weight

(mm)

(mm)

(kg/km)

1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5

17.5
20.2
22.3
24.2
27.4
30.0
32.8
35.6
40.5
44.2
48.8
55.4
60.6

695
960
1240
1495
1908
2320
2910
3550
4580
5600
7070
10660
13140

Note:
Circular or compacted circular stranded conductor (Class 2)

Product Code

PC1C50
PC1C70
PC1C95
PC1C120
PC1C150
PC1C185
PC1C240
PC1C300
PC1C400
PC1C500
PC1C630
PC1C800
PC1C1000

contd...

CU / XLPE / SWA / PVC Low Voltage Power Cables


Two Core Cables - 600/1000V
Nominal
Area of the
Conductor

Thickness of
Insulation

Thickness
of Extruded
Bedding

Diameter of Thickness of
Armour Wire Outer Sheath

(mm2)

(mm)

(mm)

(mm)

1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~

0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6

0.90
0.90
0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
2.50
2.50

Approx
Overall
Diameter

Approx.
Nett
Weight

(mm)

(mm)

(kg/km)

1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8

12.1
13.6
14.7
15.9
18.0
20.4
20.4
23.3
25.8
29.0
33.1
36.1
39.3
44.7
49.0
53.5
59.0

315
380
460
550
795
860
1000
1420
1760
2270
3120
3730
4430
5700
7060
8490
10470

Product Code

PC2C1.5
PC2C2.5
PC2C4.0
PC2C6.0
PC2C10
PC2C16
PC2C25
PC2C35
PC2C50
PC2C70
PC2C95
PC2C120
PC2C150
PC2C185
PC2C240
PC2C300
PC2C400

Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)

Three Core Cables - 600/1000V


Thickness of
Insulation

Thickness
of Extruded
Bedding

Diameter of Thickness of
Armour Wire Outer Sheath

(mm2)

(mm)

(mm)

(mm)

1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~

0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6

0.90
0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50

Approx
Overall
Diameter

Approx.
Nett
Weight

(mm)

(mm)

(kg/km)

1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9

12.6
14.1
15.3
16.6
19.5
21.6
23.6
25.7
28.5
32.2
37.0
40.4
45.5
49.8
55.1
60.2
66.6

330
415
505
615
870
1055
1485
1855
2305
3050
4190
5050
6450
7790
9680
11780
14600

Product Code

PC3C1.5
PC3C2.5
PC3C4.0
PC3C6.0
PC3C10
PC3C16
PC3C25
PC3C35
PC3C50
PC3C70
PC3C95
PC3C120
PC3C150
PC3C185
PC3C240
PC3C300
PC3C400

Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)

contd...

RAKCAB

Nominal
Area of the
Conductor

21

CU / XLPE / SWA / PVC Low Voltage Power Cables


Four Core Cables - 600/1000V
Nominal
Area of the
Conductor

Thickness of
Insulation

Thickness
of Extruded
Bedding

Diameter of Thickness of
Armour Wire Outer Sheath

(mm2)

(mm)

(mm)

(mm)

1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~

0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8

0.90
0.90
0.90
1.25
1.25
1.25
1.60
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15

Approx
Overall
Diameter

Approx.
Nett
Weight

(mm)

(mm)

(kg/km)

1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
3.2

13.3
15.0
16.4
18.7
21.1
23.4
26.1
28.6
32.0
37.7
41.7
47.1
51.4
56.6
63.0
68.8
78.1

345
440
540
780
1125
1300
1860
2335
2960
4200
5400
6990
8300
10076
12660
15350
19880

Product Code

PC4C1.5
PC4C2.5
PC4C4.0
PC4C6.0
PC4C10
PC4C16
PC4C25
PC4C35
PC4C50
PC4C70
PC4C95
PC4C120
PC4C150
PC4C185
PC4C240
PC4C300
PC4C400

Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)

Five Core Cables - 600/1000V


Nominal
Area of the
Conductor

Thickness of
Insulation

Thickness
of Extruded
Bedding

Diameter of Thickness of
Armour Wire Outer Sheath

(mm2)

(mm)

(mm)

(mm)

1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0

0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1

0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2

0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
2.00
2.00

Approx
Overall
Diameter

Approx.
Nett
Weight

(mm)

(mm)

(kg/km)

1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.2

14.3
16.1
17.8
20.0
22.9
26.6
31.5
34.8
40.4
46.3

430
545
680
840
1105
1450
2245
2840
3895
5145

Product Code

PC5C1.5
PC5C2.5
PC5C4.0
PC5C6.0
PC5C10
PC5C16
PC5C25
PC5C35
PC5C50
PC5C70

RAKCAB

Note:
Circular or compacted circular stranded conductor (Class 2)

22

contd...

CU / XLPE / SWA / PVC Low Voltage Power Cables


Single Core Copper, XLPE Insulated Armoured/Umarmoured Cables
Current Ratings & Voltage Drop of the cables - 600/1000V
(mm )
2

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

In Air
Single Core in Trefoil
Unarmoured
Armoured

22
30
39
49
67
92
123
146
174
222
275
321
371
430
513
594
692
801
925
1051
1172

Operating conditions

Ambient air temperature


Ground temperature
Depth of laying
Thermal resistivity of soil

22
30
39
49
67
92
123
146
180
230
282
328
377
433
510
581
664
751
846
919
997

:
:
:
:

In Ground
In Duct (A)
Voltage Drop of 3
Single Core in Trefoil Single Core in Trefoil Single core cables Trefoil
Armoured
Armoured
(V/A/km)

28
38
49
62
82
108
139
165
199
244
292
332
371
417
480
536
594
658
723
764
810

26
35
46
59
78
101
134
154
199
239
281
315
341
376
421
459
488
529
571
595
632

26.7
16.4
10.2
6.80
4.00
2.50
1.62
1.17
0.88
0.62
0.46
0.38
0.32
0.28
0.23
0.21
0.20
0.18
0.17
0.16
0.15

50OC
35OC
0.50m
1.2 Km/W

contd...

RAKCAB

Area

23

CU / XLPE / SWA / PVC Low Voltage Power Cables


Two Core Copper, XLPE Insulated Armoured/Umarmoured Cables
Current Ratings & Voltage Drop of the cables - 600/1000V
In Air

Area
(mm2)

Unarmoured

Armoured

In Ground
Armoured

In Duct (A)
Armoured

Voltage Drop
(V/A/km)

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

22
30
39
50
67
97
122
151
183
232
287
335
383
444
529
611
711

24
32
43
55
74
98
128
158
190
239
295
341
289
449
530
605
696

33
42
56
70
94
121
157
188
223
273
328
372
417
470
544
609
687

27
35
46
58
77
99
127
153
181
224
269
307
345
391
453
509
575

30.9
18.9
11.8
7.90
4.70
2.90
1.90
1.35
1.00
0.70
0.52
0.42
0.35
0.90
0.24
0.21
0.20

Operating conditions

Ambient air temperature


Ground temperature
Depth of laying
Thermal resistivity of soil

:
:
:
:

50OC
35OC
0.50m
1.2 Km/W

RAKCAB

Three & Four Core Copper, XLPE Insulated Armoured/Umarmoured Cables


Current Ratings & Voltage Drop of the cables - 600/1000V

24

In Air

Area
(mm2)

Unarmoured

Armoured

In Ground
Armoured

In Duct (A)
Armoured

Voltage Drop
(V/A/km)

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

19
27
34
44
58
83
105
129
157
200
246
288
330
381
454
524
608

20
27
37
46
64
83
109
134
163
205
253
293
335
386
456
519
597

28
36
47
59
79
102
131
157
187
229
274
312
349
394
455
509
574

22
29
39
48
65
83
107
128
152
187
226
258
291
329
380
427
490

26.7
16.4
10.2
6.80
4.00
2.50
1.65
1.15
0.87
0.60
0.45
0.37
0.30
0.26
0.21
0.19
0.17

Operating conditions

Ambient air temperature


Ground temperature
Depth of laying
Thermal resistivity of soil

:
:
:
:

50OC
35OC
0.50m
1.2 Km/W

Auxiliary Cables 600/1000V

APPLICATION
Industrial wiring for remote control and telemetry circuits etc. Can be laid direct in
the ground, or in ducts, clipped to surface, on trays or in free air.

CONSTRUCTION
Multi-core cables. Stranded plain copper conductors, XLPE insulated, cores laid up,
extruded PVC bedding, galvanised steel wire armoured and PVC sheathed.

STANDARD COLOURS
Cores
: White with Black numerals
Sheath Colours : Black. Other colours available on request

MINIMUM BENDING RADIUS


6D circular conductors

TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS5467

12

19

27

37

48

Nominal Area
of Conductor

Approx.
Dia. under
Armour

Approx. Dia.
over Armour

Approx.
Overall
Diameter

Approx
Net
Weight

(mm2)

(mm)

(mm)

(mm)

(kg/km)

1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0

10.2
12.3
14.0
13.7
16.3
19.1
16.2
19.9
22.5
20.0
24.0
27.5
22.3
26.9
31.0
25.4
31.0
35.3

12.1
14.1
16.5
16.2
18.8
22.2
18.7
23.1
25.7
23.2
27.2
30.7
25.5
30.1
35.0
28.6
35.0
39.3

15.2
17.1
19.7
19.4
22.4
25.7
22.2
26.6
29.3
26.7
30.7
34.4
29.0
33.8
39.2
32.7
39.3
44.1

470
600
890
780
1000
1410
1000
1540
1830
1500
1950
2500
1800
2350
3100
2050
3100
4100

Product Code

AX7C1.5
AX7C2.5
AX7C4.0
AX12C1.5
AX12C2.5
AX12C4.0
AX19C1.5
AX19C2.5
AX19C4.0
AX27C1.5
AX27C2.5
AX27C4.0
AX37C1.5
AX37C2.5
AX37C4.0
AX48C1.5
AX48C2.5
AX48C4.0

RAKCAB

Number of
Cores

25

TELECOMMUNICATION
DATA & INSTRUMENTATION
CABLES

Internal Telephone Cables

APPLICATION
Internal telephone cables generally conform to British & International Telecommunications authorities
specifications.
Type 1308 cable has each individual core of a different bi-colour for easy identification. In the color coding tables
the first color is that of the PVC insulation and the second is the stripe color.
These cables are suitable for cross connecting individual items of switchboard equipments, and are used where
an external telephone cable is to be connected to many internal distribution points - in a large block of flats or
in a small commercial premises not equipped with private exchanges. These cables are ideal for direct
connection on to terminal blocks.

CONSTRUCTION
Cable Type : Cu/PVC/PVC
Conductor : Solid plain/tinned copper wire to BS4109.
Insulation : PVC to BS6746.
Lay-up
: In full units of 16,20,30 pairs sub-units of 8,10,15 pairs - each unit identified by a different
colored lapping tape; units are laid up together to form a compact circular cable
Wrapping : Polyester clear tape.
Sheath
: PVC (Cream, white, grey or black) to BS6746. Fitted with a nylon ripcord for easy stripping.

RAKCAB

No. of
Pairs

28

0.5mm

No. of
Cores

A-Wire
Insul.

BLU

B-Wire
Insul.

BLU

Insul.
Res.

Cap. Approx. PART NO.


Unbal- Weight
ance

(/km)

(M/
km)

(PF)500M

(kg/km)

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Sheath Approx. Cond.


OD
R/T
Res. at
20OC

(mm2)

(mm)

(mm)

(mm)

(mm)

WHI

No. of
Pairs

WHI

WHI ORG ORG WHI

0.2

0.2

0.9

0.6

3.5

97.8

50

500

18

TI5002

1
2

WHI GRN GRN WHI

0.2

0.2

0.9

0.7

4.3

97.8

50

500

27

TI5003

WHI BRN

BRN WHI

0.2

0.2

0.9

0.7

4.7

97.8

50

500

33

TI5004

10

WHI

GRY

GRY

WHI

0.2

0.2

0.9

0.7

5.1

97.8

50

500

39

TI5005

12

RED

BLU

BLU

RED

0.2

0.2

0.9

0.7

5.5

97.8

50

500

45

TI5006

14

RED ORG ORG RED

16

RED GRN GRN RED

0.2

0.2

0.9

0.7

6.1

97.8

50

500

57

TI5008

18

RED

BRN

BRN

RED

10

20

RED

GRY

GRY

RED

0.2

0.2

0.9

0.7

6.6

97.8

50

500

69

TI5010

10

11

22

BLK

BLU

BLU

BLK

12

24

BLK

ORG ORG

BLK

0.2

0.2

0.9

0.8

7.3

97.8

50

500

83

TI5012

13

26

BLK

GRN GRN

BLK

14

28

BLK

BRN

BRN

BLK

15

30

BLK

GRY

GRY

BLK

16

32

YEL

BLU

BLU

YEL

16

17

34

YEL

ORG ORG

YEL

17

18

36

YEL

GRN GRN

YEL

18

19

38

YEL

BRN

BRN

YEL

20

40

YEL

GRY

GRY

YEL

21

42

VIO

BLU

BLU

VIO

21

22

44

VIO

ORG ORG

VIO

22

23

46

VIO

GRN GRN

VIO

23

24

48

VIO

BRN

BRN

VIO

25

50

VIO

GRY

GRY

VIO

26

52

PNK

BLU

BLU

PNK

26

27

54

PNK ORG ORG PNK

27

28

56

PNK GRN GRN PNK

28

29

58

PNK

BRN

BRN

PNK

30

60

PNK

GRY

GRY

PNK

7
9
11
12
13
14
0.2

0.2

0.9

0.8

8.0

97.8

50

500

100

TI5015

15

19
0.2

0.2

0.9

0.9

9.2

97.8

50

500

133

TI5020

20

24
0.2

0.2

0.9

0.9

10.1

97.8

50

500

162

TI5025

25

29
0.2

0.2

0.9

1.0

11.1

97.8

50

500

194

TI5030

30
40

Unit construction cables (Laid up in 10 and 20 pair units as per above color coding.)
40

80

0.2

0.2

0.9

1.0

12.5

97.8

50

500

249

TI5040

50

100

0.2

0.2

0.9

1.2

14.1

97.8

50

500

316

TI5050

50

100

200

0.2

0.2

0.9

1.6

19.7

97.8

50

500

622

TI5100

100

200

400

0.2

0.2

0.9

1.8

27.0

97.8

50

500

1181

TI5200

200

External Telephone Cables

0.5mm

APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.

CONSTRUCTION
Conductor : Plain anealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen

No. of
Pairs

No. of
Cores

A-Wire
Insul.

B-Wire
Insul.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Sheath Approx. Cond.


R/T
OD
Res. at
20OC

(mm2)

(mm)

(mm)

(mm)

(mm)

(/km)

Insul.
Res.

Cap. Approx. PART NO.


Unbal- Weight
ance

(M/
km)

(PF)500M

No. of
Pairs

(kg/km)

WHI

BLU

WHI

ORG

WHI

GRN

WHI

BRN

10

WHI

GRY

12

RED

BLU

14

RED

ORG

16

RED

GRN

18

RED

BRN

10

20

RED

GRY

4
0.2

0.2

0.9

1.1

12.5

91

1500

275

62

TE5005

9
0.2

0.2

0.9

1.1

14.5

91

1500

275

103

TE5010

10

Cables over 10 pair are constructed with 10 pair units with above color coding
20

40

0.2

0.2

0.9

1.2

13.5

91

1500

275

168

TE5020

20

30

60

0.2

0.2

0.9

1.2

15.5

91

1500

275

230

TE5030

30

50

100

0.2

0.2

0.9

1.3

18.0

91

1500

275

333

TE5050

50

100

200

0.2

0.2

0.9

1.4

23.5

91

1500

275

591

TE5100

100

Unit 1

BLU

Unit 2

ORG

Unit 3

GRN

Unit 4

BRN

Unit 5

GRY

Unit 6

WHI

Unit 7

RED

Unit 8

BLK

Unit 9

YEL

Unit 10

VIO

RAKCAB

Each unit is lapped with colored tape for identication as follows

29

External Telephone Cables

0.63mm

APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.

CONSTRUCTION
Conductor : Plain annealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen

No. of
Pairs

No. of
Cores

A-Wire
Insul.

B-Wire
Insul.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Sheath Approx. Cond.


R/T
OD
Res. at
20OC

Insul.
Res.

Cap. Approx. PART NO.


Unbal- Weight
ance

(mm2)

(mm)

(mm)

(mm)

(mm)

(/km)

(M/
km)

(PF)500M

(kg/km)

0.31

0.25

1.15

1.1

9.5

60

1500

800

41

No. of
Pairs

WHI

BLU

WHI

ORG

WHI

GRN

WHI

BRN

10

WHI

GRY

12

RED

BLU

14

RED

ORG

16

RED

GRN

18

RED

BRN

10

20

RED

GRY

TE6002

2
3
4

0.31

0.25

1.15

1.1

11.0

60

1500

275

90

TE6005

9
0.31

0.25

1.15

1.2

13.0

60

1500

275

145

TE6010

10

Cables over 10 pair are constructed with 10 pair units with above color coding
20

40

0.31

0.25

1.15

1.2

15.5

60

1500

275

242

TE6020

20

30

60

0.31

0.25

1.15

1.3

18.0

60

1500

275

310

TE6030

30

50

100

0.31

0.25

1.15

1.4

22.0

60

1500

275

489

TE6050

50

100

200

0.31

0.25

1.15

1.6

27.5

60

1500

275

850

TE6100

100

RAKCAB

Each unit is lapped with colored tape for identication as follows

30

Unit 1

BLU

Unit 2

ORG

Unit 3

GRN

Unit 4

BRN

Unit 5

GRY

Unit 6

WHI

Unit 7

RED

Unit 8

BLK

Unit 9

YEL

Unit 10

VIO

External Telephone Cables

0.9mm

APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.

CONSTRUCTION
Conductor : Plain anealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen

No. of
Pairs

No. of
Cores

A-Wire
Insul.

B-Wire
Insul.

Insul.
Res.

Cap. Approx. PART NO.


Unbal- Weight
ance

(/km)

(M/
km)

(PF)500M

(kg/km)

30

1500

800

60

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Sheath Approx. Cond.


R/T
OD
Res. at
20OC

(mm2)

(mm)

(mm)

(mm)

(mm)

0.64

0.3

1.5

1.1

10.5

No. of
Pairs

WHI

BLU

WHI

ORG

WHI

GRN

WHI

BRN

10

WHI

GRY

12

RED

BLU

14

RED

ORG

16

RED

GRN

18

RED

BRN

10

20

RED

GRY

TE9002

2
3
4

0.64

0.3

1.5

1.2

13.0

30

1500

275

121

TE9005

9
0.64

0.3

1.5

1.2

15.5

30

1500

275

231

TE9010

10

Cables over 10 pair are constructed with 10 pair units with above color coding
20

40

0.64

0.3

1.5

1.3

19.5

30

1500

275

417

TE9020

20

30

60

0.64

0.3

1.5

1.5

24.0

30

1500

275

563

TE9030

30

50

100

0.64

0.3

1.5

1.5

28.0

30

1500

275

896

TE9050

50

100

200

0.64

0.3

1.5

1.7

36

30

1500

275

1650

TE9100

100

Unit 1

BLU

Unit 2

ORG

Unit 3

GRN

Unit 4

BRN

Unit 5

GRY

Unit 6

WHI

Unit 7

RED

Unit 8

BLK

Unit 9

YEL

Unit 10

VIO

RAKCAB

Each unit is lapped with colored tape for identication as follows

31

Direct Burial Armoured Cables

APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.

CONSTRUCTION
The construction of the external telephone cable shall be to the relevant BT specification and shall have:
Armour
: Suitable number of galvanised mild steel wires, to comply with BS1442, applied directly over
the sheath
Oversheath : The wire armoured cable shall be oversheathed with an extrusion of Polyethylene (Black).
If specially ordered the oversheath can be of PVC compound.

RAKCAB

Specied Cable Diameter


(Maximum)
Inclusive Range

32

Diameter of
Armour Wire
Nominal

Thickness of
Oversheath
Minimum

Increase in
Cable Dia. Due To
Armour &
Oversheath
Maximum

(mm)

(mm)

(mm)

(mm)

(mm)

12

0.90

0.9

5.2

12.1

15

1.25

0.9

5.9

15.1

20

1.60

1.0

6.8

20.1

25

1.60

1.1

7.0

25.1

30

2.00

1.2

8.0

30.1

35

2.00

1.3

8.2

35.1

40

2.00

1.4

8.4

40.1

45

2.50

1.5

9.6

45.1

50

2.50

1.6

9.8

50.1

55

2.50

1.7

10.0

55.1

60

2.50

1.8

10.2

60.1

65

3.15

1.9

11.7

65.1

70

3.15

2.0

11.9

70.1

3.15

2.1

12.1

ELAKY Type Cables 60V/70OC

0.65mm

APPLICATION
External grade cable for data transmission and local network distribution systems.

CONSTRUCTION
Conductor : Solid, plain copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with aluminium/copper tape
Sheath
: PVC to BS6746 (Black)

No. of
Pairs

No. of
Cores

A-Wire
Insul.

B-Wire
Insul.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Sheath Approx. Cond.


R/T
OD
Res. at
20OC

(mm2)

(mm)

(mm)

(mm)

(mm)

(/km)

Insul.
Res.

Cap. Approx. PART NO.


Unbal- Weight
ance

(M/
km)

(PF)500M

No. of
Pairs

(kg/km)

WHI

BLU

WHI

ORG

0.33

0.24

1.13

1.5

7.15

56

10000 150

58

TL6002

1
2

WHI

GRN

0.33

0.24

1.13

1.5

7.25

56

10000 150

68

TL6003

WHI

BRN

10

WHI

GRY

0.33

0.24

1.13

1.5

9.76

56

10000 150

105

TL6005

12

RED

BLU

0.33

0.24

1.13

1.5

9.76

56

10000 150

130

TL6006

14

RED

ORG

16

RED

GRN

18

RED

BRN

10

20

RED

GRY

9
0.33

0.24

1.13

1.5

11.55

56

10000 150

158

TL6010

10

Cables over 10 pair are constructed with 10 pair units with above color coding
20

40

0.33

0.24

1.13

1.5

14.07

56

10000 150

252

TL6020

20

30

60

0.33

0.24

1.13

1.5

15.96

56

10000 150

347

TL6030

30

40

80

0.33

0.24

1.13

1.5

17.75

56

10000 150

420

TL6040

40

50

100

0.33

0.24

1.13

1.7

19.32

56

10000 150

515

TL6050

50

60

120

0.33

0.24

1.13

1.7

20.07

56

10000 150

599

TL6060

60

70

140

0.33

0.24

1.13

1.7

22.05

56

10000 150

683

TL6070

70

100

200

0.33

0.24

1.13

1.7

25.50

56

10000 150

903

TL6100

100

Unit 1

BLU

Unit 2

ORG

Unit 3

GRN

Unit 4

BRN

Unit 5

GRY

Unit 6

WHI

Unit 7

RED

Unit 8

BLK

Unit 9

YEL

Unit 10

VIO

RAKCAB

Each unit is lapped with colored tape for identication as follows

33

Drop Wires

0.81mm

APPLICATION
Dropwire No.6 is used for the connection of subscriber's distribution points to the external, overhead
distribution point.

CONSTRUCTION
Conductor : Copper covered steel wire to BS4807
Insulation : PVC to BS6746 (Black or Grey)
No. of
Pairs

No. of
Cores

Insul.
Res.

Approx. PART NO.


Weight

(/km)

(M/
km)

(kg/km)

122

50

15

Cond.
Area

Cond. Approx. Cond.


Insul.
OD
Res. at
R/T
20OC

(mm2)

(mm)

0.52

0.76

(mm)

2.5
x 5.4

DW8108

No. of
Pairs

5.4 mm

0.5 mm

2.5 mm

Drop Wires

APPLICATION
This drop wire is used for overhead distribution to the subcribers installation.

CONSTRUCTION
Conductor : Plain annealed copper wire to BS4109
Insulation : PVC (Black)
Cabling
: Two copper conductors of the drop wire and fibre glass roving of suitable dimensions shall be
insulated with PVC compound extruded over the fibre glass roving integral with the conductor
wires to form a cross-section of the shape as given below
No. of
Pairs

RAKCAB

34

0.5mm

No. of
Cores

Insul.
Res.

Approx. PART NO.


Weight

(/km)

(M/
km)

(kg/km)

91

20

15

Cond.
Area

Cond. Approx. Cond.


Insul.
OD
Res. at
R/T
20OC

(mm2)

(mm)

0.2

0.4

(mm)

2.5
x 5.4

DW50F1

No. of
Pairs

0.4 mm OR MORE
THICK PVC INSULATION

IDENTIFICATION
FIN
WEB

FIBRE GLASS ROVING


0.5mm
COPPER
CONDUCTOR

1.4-1.6
1.3

2.2-2.4

0.5

Jumper Wires & Equipment Wires


Jumper wires & Equiment wires are utilised for cross connections on instrument panels, and throughout industry
on all types of electronics equipment.
JUMPER WIRES

CONSTRUCTION
Conductor : Solid tinned copper wire to BS4109
Insulation : PVC to BS6746
No. of
Cores

Cond.
Dia.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Cond.
Res. at
20OC

Insul.
Res.

Approx. PART NO.


Weight

(mm)

(mm2)

(mm)

(mm)

(/km)

(M/
km)

(kg/km)

0.4

0.13

0.25

1.0

153

50

3.43

JW4002

0.5

0.20

0.25

1.1

98

50

5.45

JW5002

0.6

0.28

0.25

1.2

68

50

7.40

JW6002

SOLID CONDUCTORS

CONSTRUCTION
Conductor : Solid tinned copper wire to BS4109
Insulation : PVC to BS6746
Options
: Single or bi-colours
No. of
Cores

Insul.
Res.

Approx. PART NO.


Weight

(/km)

(M/
km)

(kg/km)

0.85

150

50

1.65

ES4001

0.2

0.95

65

50

2.4

ES5001

0.28

0.2

1.05

65

50

3.2

ES6001

0.64

0.25

1.6

29

50

7.0

ES9001

Cond.
Dia.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Cond.
Res. at
20OC

(mm)

(mm2)

(mm)

(mm)

0.4

0.126

0.2

0.5

0.20

0.6

0.9

STRANDED CONDUCTORS
CONSTRUCTION
Conductor : Solid tinned copper wire to BS6360
Insulation : PVC to BS6746
Options
: Single or bi-colours
Cond.

Insul.
Res.

Cond.
Area

Cond.
Insul.
R/T

Core
Dia.

Approx.
OD

Cond.
Res. at
20OC

(mm2)

(mm)

(mm)

(mm)

(/km)

(M/
km)

7x
0.2mm

0.22

0.30

1.20

1.2

83

50

16x
0.2mm

0.50

0.45

1.85

1.81

40

50

Rating Weight

PART NO.

(kg/km)

220/
1A
220/
2.5A

5.5

EF7201

7.5

EF16201

RAKCAB

35

Data Cables

Cat 5E

UNSCREENED TWISTED PAIR (UTP) CABLES - DATA CABLE


This cable meets or exceeds the requirements of TIA/EIA 568-B.2 and ISO/IEC 11801. Suitable
for transmission of high speed data, digital and analogue voice and video (RGB) signals on LANs.
Support Gigabit Ethernet (1000 baseT) standard.
CONSTRUCTION
Cable Type : Cu / PVC
Conductor : 24 AWG solid bare copper
Insulation : Polyethylene
Pairs
: 2 insulated conductors twisted together, lays varied to minimise crosstalk.
4 pairs twisted together.
Sheath
: PVC (Grey,Orange, Blue) or LSOH (Violet), 6.35mm overall diameter maximum.
Other colours available on request.
COLOR CODE
Pair

Conductor 1

Conductor 2

Blue

White / Blue

Orange

White / Orange

Green

White / Green

Brown

White / Brown

CONNECTION SYSTEMS
Compatible with all common systems according to EN 50173, ISO/IEC 11801 and TIA/EIA 568-B.
ELECTRICAL PROPERTIES
Conductor Resistance : < 9.38 /100m
Mutual Capacitance
: < 5.6 nF/100m
Resistance Unbalance : 3% maximum
Capacitance Unbalance : 330 pF/km
Delay Skew
: < 45 ns
NVP
: 68%

MECHANICAL PROPERTIES
Bending Radius
During Installation : > 42 mm
After Installation
: > 21 mm
Pulling Force
: < 65 N
Temperature Range : -15C +/-70C
Heat of Combustion : 373 MJ/km

RAKCAB

PACKAGING
Available in easy-pull boxes (305m) or non-returnable reels of longer lengths.

36

Frequency

Attenuation

NEXT

PSNEXT

ELFEXT

PSELFEXT

Return Loss

(Mhz)

(db/100m)

(db/100m)

(db/100m)

(db/100m)

(db/100m)

(db)

0.77

1.8

67.0

64.0

66.0

63.0

1.00

2.0

65.3

62.3

63.8

60.8

20.0

4.00

4.1

56.3

53.3

51.7

48.7

23.0

8.00

5.8

51.8

48.8

45.7

42.7

24.5

10.00

6.5

50.3

47.3

43.8

40.8

25.0

16.00

8.2

47.3

44.3

39.7

36.7

25.0

20.00

9.3

45.8

42.8

37.7

34.7

25.0

25.00

10.4

44.3

41.3

35.8

32.8

24.3

31.25

11.7

42.9

39.9

33.9

30.9

23.6

62.50

17.0

38.4

35.4

27.8

24.8

21.5

100.00

22.0

35.3

32.3

23.8

20.8

20.0

Data Cables

Cat 6

UNSCREENED TWISTED PAIR (UTP) CABLES - DATA CABLE


This cable meets or exceeds the requirements of TIA/EIA 568-B.2 and ISO/IEC 11801. Suitable for
transmission of high speed data, digital and analogue voice and video (RGB) signals on LANs.
Support Gigabit Ethernet (1000 baseT) standard. The X-Seperator at the center ensures Cat 6
performance.
CONSTRUCTION
Cable Type : Cu / PVC
Conductor : 0.56mm solid bare copper
Insulation : Polyethylene
Pairs
: 2 insulated conductors twisted together, lays varied to minimise crosstalk.
4 pairs twisted together.
Sheath
: PVC (Grey,Orange, Blue) or LSOH (Violet), 6.50mm overall diameter maximum.
Other colours available on request.
COLOR CODE
Pair

Conductor 1

Conductor 2

Blue

White / Blue

Orange

White / Orange

Green

White / Green

Brown

White / Brown

CONNECTION SYSTEMS
Compatible with all common systems according to EN 50173, ISO/IEC 11801 and TIA/EIA 568-B.
ELECTRICAL PROPERTIES
Conductor Resistance : 141 /100m
Mutual Capacitance
: 49 pF/km (nom.)
Resistance Unbalance : 2% maximum
Capacitance Unbalance : 1600 pF/km
Delay Skew
: 400 ns/km
NVP
: 68%

MECHANICAL PROPERTIES
Bending Radius
During Installation : 8xD
After Installation
: 4xD
Pulling Force
: 100 N
Temperature Range : -15C +60C
Heat of Combustion : 373 MJ/km

Frequency

Attenuation

NEXT

PSNEXT

ELFEXT

PSELFEXT

Return Loss

(Mhz)

(db/100m)

(db/100m)

(db/100m)

(db/100m)

(db/100m)

(db)

1.0

2.0

74.3

72.3

67.8

64.8

20.0

4.0

3.8

65.3

63.3

55.8

52.8

23.0

8.0

5.3

60.8

58.8

49.7

46.7

24.5

10.0

6.0

59.3

57.3

47.8

44.8

25.0

16.0

7.6

56.2

54.2

43.7

40.7

25.0

20.0

8.5

54.8

52.8

41.8

38.8

25.0

25.0

9.5

53.3

51.3

39.8

36.8

24.3

31.25

10.7

51.9

49.9

37.9

34.9

23.6

62.5

15.4

47.4

54.4

31.9

28.9

21.5

100.0

19.8

44.3

42.3

27.8

24.8

20.1

200.0

29.0

39.8

37.8

21.8

18.8

18.0

250.0

32.8

38.3

36.3

19.8

16.8

17.3

SuperLAN
HIGH PERFORMANCE DATA CABLES

RAKCAB

PACKAGING
Available in easy-pull boxes (305m) or non-returnable reels of longer lengths.

37

Instrumentation Cables
MULTIPAIR / MULTICORE INSTRUMENTATION CABLES
Generally to BS5308 Parts 1 & 2
INSTRUMENTATION CABLES -generally to BS5308
Conforming to British Standard Authorities specifications, instrumentation cables are
suitable for computer-controlled electrical and electronic equipment.
PART 1 - POLYETHYLENE INSULATED
CONSTRUCTION
Conductor
Insulation
Voltage
Pair Identification

Binder Tape
Collective Screen
Outer Protection

: Plain Annealed Copper


: Polyethylene BS6234 Type 03
: 300V core to earth & 500V core to core at max.
Temperature of 65C
: (a) Collectively screened cables
(b) Individually screened pairs - one blue core and one black core in each pair.
1. Pairs identified by numbered tapes
2. Pair screens - aluminium / p.e.t.p. laminated tape applied with the metallic
side down in electrical contact with a 0.5 sq.mm tinned copper drain wire.
: A 23 micron polyester tape applied with a minimum 50% overlap.
: Aluminimum / polyester laminated tape applied with the metallic side down in
electrical contact with a 0.5 sq.mm tinned copper drain wire over the polyester
binder tape.
: TYPE 1 - Extruded flame retardent PVC sheath
TYPE 2 - Extruded polyethylene bedding
Galvanised steel wire armour
Extruded flame retardant PVC sheath

PART 2 - PVC INSULATED


CONSTRUCTION
Conductor
Insulation
Voltage

: Plain Annealed Copper


: PVC to BS6746 Type T1
: 300V core to earth & 500V core to core at max.
Temperature of 65C
Core / Pair Identification : Multipair Cables
Binder Tape
: A 23 micron p.e.t.p. tape applied with a minimum 50% overlap
Collective Screen
: Aluminimum / p.e.t.p. laminated tape applied with the metallic side down in
electrical contact with a 0.5 sq.mm tinned copper drain wire over the polyester
binder tape.
Outer Protection
: TYPE 1 - Extruded flame retardent PVC sheath
TYPE 2 - Extruded polyethylene bedding
Galvanised steel wire armour
Extruded flame retardant PVC sheath

RAKCAB

Note: These cables are not for direct connection to public mains electricity supply.

38

RAS AL KHAIMAH
Cables FZC
P O Box: 10559, RAK Free Trade Zone
Ras-Al-Khaimah, United Arab Emirates.
Tel: + 971 7 266 0013
Fax: + 971 7 266 0014
E-mail: info@rakcables.com
www.rakcables.com

Vous aimerez peut-être aussi