Académique Documents
Professionnel Documents
Culture Documents
RAKCAB
About us...
Ras Al Khaimah Cables FZC. is established in Ras-Al-Khaimah, U.A.E.
The manufacturing facility is located at Industrial Park in the RAK
Free Trade Zone located 130kms from Dubai. It utilizes advanced
cable making equipment and technology to produce specialized range
of cables for use in various applications.
The company is formed by leading technocrats having wide
experience in manufacturing and marketing of various kinds of cables
& related products in the Telecom & Electrical industry. The
promoters have a strong presence in the U.A.E
PRODUCT RANGE
Ras Al Khaimah Cables wide range of products includes:
- Building Construction
Wires and Wiring Cables, Indoor Telecom Cables, Networking
Cables and solutions
- Industry
Control & Instrumentation Cables
- Infrastructure
Low Voltage Power Cables, External Telecom Cables
QUALITY STATEMENT
Ras Al Khaimah Cables has an objective of providing high
quality products & services to its customers at a right
price through competitive approach.
Quality is our competency, which is achieved by our
qualified & dedicated staff to ensure product excellence.
RAKCAB
DISTRIBUTION NETWORK
The company is marketing their range of products under the brand name RAKCAB throughout the GCC, Middle
East & Africa, and CIS countries and has a wide distribution network in the region. Taking advantage of the
proximity to the sea port and developed highway network, we have one of the quickest delivery schedules in the
cabling industry for complex and standard cables.
ENVIRONMENTAL POLICIES
We at Ras Al Khaimah Cables maintain a safe & healthy working environment for our employees and ensure
compliance to changing business practices in health and safety worldwide. We are committed to environmentally
conscious operations & products.
Contents
ELECTRICAL WIRES & CABLES
Building Wires
Single Core PVC Insulated Wires..............................................................................................................................................
BS6004 | H07V-U/R
Bare Copper & Yellow/Green Earthing Conductor..............................................................................................................
BS6004 | H07V-U/R
Single Core PVC Insulated & Sheathed Wires .......................................................................................................................
BS6004/BS6346
Single Core XLPE Insulated, PVC Sheathed (Unarmoured) ................................................................................................
BS6346/BS7889
LSF Wiring Cables.........................................................................................................................................................................
BS7211 | H07Z-U/R
Panel Wires
Heat Resisting PVC Insulated Panel Wires .............................................................................................................................
BS6231 | H07V2-K
6
7
8
9
10
11
12
14
16
18
18
20
23
25
28
29
30
31
32
33
Drop Wires
Drop Wires 0.81mm ..................................................................................................................................................................
34
34
35
Data Cables
SUPERLAN Cat 5E........................................................................................................................................................................
36
37
Instrumentation Cables
Instrumentation Cables................................................................................................................................................................
38
RAKCAB
ELECTRICAL
WIRES & CABLES
APPLICATION
These cables are intended for drawing into trunking and conduit and are suitable for use
in electrical installations such as power, lighting, appliances and switchgear wiring.
HARMONISED CODE
- 0.75mm2 & 1.0mm2 solid conductor wire
H05V-U
- 1.5mm2 & 2.5mm2 solid conductor wire
H07V-U
- 1.5mm2 to 120mm2 stranded conductor wire H07V-R
CONSTRUCTION
Reference
: 6491X or 6491X HR*
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655
* PVC Type TI 3 HR to BS7655
STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green, Brown, Grey
Other colours available on request
PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m
- Customised lengths available on request
TECHNICAL DATA
Max. Operating Temperature : 70OC/ *105OC
Rated Voltage
: 450/750V (300/500V for 0.75mm2 & 1.0mm2)
Standards
: Generally to BS6004
Nominal
CrossSectional
Area
Conductor
Number of Diameter of
Strands
Strand
RAKCAB
(mm2)
0.75
1.00
1.50
1.50
2.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
1
1
1
7
1
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
91
91
Max.
Resistance
at 20OC
Radial
Thickness
of Insulation
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(kg/km)
(A)
0.98
1.13
1.38
0.53
1.78
0.67
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50
2.85
2.65
2.97
24.50
18.10
12.10
12.10
7.410
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2
2.6
2.8
2.8
2.40
2.60
3.20
3.30
3.90
4.00
4.60
5.20
6.70
7.80
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60
33.20
36.90
41.10
11
14
21
22
32
35
50
71
120
180
280
380
510
710
970
1200
1480
1900
2480
3100
3940
5000
6350
10
12
16
16
21
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611
Product Code
SCO0.75
SCO1.0
SCO1.5
SC1.5
SCO2.5
SC2.5
SC4.0
SC6.0
SC10.0
SC16.0
SC25.0
SC35.0
SC50.0
SC70.0
SC95.0
SC120.0
SC150.0
SC185.0
SC240.0
SC300.0
SC400.0
SC500.0
SC630.0
Note:
* 0.75mm2 x single core HR PVC insulated 105OC available. Suitable for flourescent lights wiring.
APPLICATION
These cables are intended for use in electrical installations for earthing purpose
CONSTRUCTION
Conductor
: Stranded plain copper class 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655 for Yellow/Green earth wire only
PACKAGING
- All sizes can be supplied in non-returnable ply/wooden reels of 500m and 1000m
- Customised lengths available on request
TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 450/750V
Standards
: BS6004
BARE COPPER
Nominal
CrossSectional
Area
Conductor
Number of
Diameter of
Strands
Strand
(mm2)
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
7
7
7
7
19
19
19
37
37
37
61
61
Max.
Resistance at
20OC
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(kg/km)
(A)
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.27
2.52
2.25
2.50
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
4.05
5.10
6.42
7.56
9.15
10.85
12.60
14.28
15.89
17.64
15.75
22.50
88.90
142.24
222.25
311.15
444.50
622.30
844.55
1066.80
1333.50
1644.65
2133.60
2667.00
50
68
89
110
134
171
207
239
262
296
346
394
Product Code
BC10.0
BC16.0
BC25.0
BC35.0
BC50.0
BC70.0
BC95.0
BC120.0
BC150.0
BC185.0
BC240.0
BC300.0
(mm2)
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
7
7
7
7
19
19
19
37
37
37
61
61
Max.
Resistance
at 20OC
Radial
Thickness
of Insulation
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(kg/km)
(A)
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2
6.70
7.10
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60
110
171
260
350
480
680
930
1160
1430
1740
2270
2840
50
68
89
110
134
171
207
239
262
296
346
394
Product Code
SC10.0YG
SC16.0YG
SC25.0YG
SC35.0YG
SC50.0YG
SC70.0YG
SC95.0YG
SC120.0YG
SC150.0YG
SC185.0YG
SC240.0YG
SC300.0YG
RAKCAB
Nominal
CrossSectional
Area
APPLICATION
These cables are intended for surface wiring where there is little risk of mechanical
damage and are suitable for use in electrical installations such as power and lighting.
CONSTRUCTION
Reference
: 6181Y
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 to BS7655
Sheath
: PVC Type TM 1 or Type 6 to BS7655
STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green, Brown, Grey
Other colours available on request
PACKAGING
- Sizes 1.5mm2 to 4mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m
TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 1.0mm2 to 35.0mm2 - 300/500V
50.0mm2 and above - 600/1000V
Standards
: 1.0mm2 to 35.0mm2 - BS6004
50.0mm2 and above - BS6346
Nominal
CrossSectional
Area
Conductor
Number Diameter
of Strands of Strand
(mm2)
RAKCAB
1.00
1.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
1
1
1
7
7
7
7
7
7
19
19
19
37
37
37
37
61
61
91
91
Max.
Resistance
at 20OC
Radial
Thickness
of
Insulation
Radial
Thickness
of
Sheath
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(mm)
(kg/km)
(A)
1.13
1.38
1.78
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.27
2.52
2.87
2.50
2.85
2.65
2.97
18.10
12.10
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.60
0.70
0.80
0.80
0.80
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.00
2.20
2.20
2.20
2.50
0.80
0.80
0.80
0.90
0.90
0.90
1.00
1.10
1.10
1.40
1.40
1.50
1.50
1.80
2.00
2.00
2.20
2.20
2.20
2.50
4.50
4.90
5.80
6.80
7.40
8.80
10.50
12.50
13.50
14.75
16.45
18.80
20.48
23.09
25.64
28.09
31.03
35.00
38.50
43.50
26
35
49
74
97
147
218
327
426
594
793
1062
1307
1646
2031
2563
3195
4156
5114
6459
12
16
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611
Product Code
SCS1.0
SCS1.5
SCS2.5
SCS4.0
SCS6.0
SCS10.0
SCS16.0
SCS25.0
SCS35.0
SCS50.0
SCS70.0
SCS95.0
SCS120.0
SCS150.0
SCS185.0
SCS240.0
SCS300.0
SCS400.0
SCS500.0
SCS630.0
CONSTRUCTION
Reference
: 6181XY
Conductor
: Stranded plain copper conductor class 2 to BS6360/IEC60228-1
Insulation
: XLPE
Sheath
: PVC Sheathed
STANDARD COLOURS
Cores
: Brown or Blue
Sheath
: Black. Other colours available on request
PACKAGING
All sizes can be supplied in non-returnable wooden drums of 500m/1000m
TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS7889, BS6346, IEC60502
Nominal
CrossSection
Area
Copper Conductor
Number Diameter
of Strands of Strand
(mm2)
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
19
19
19
37
37
37
37
61
61
91
91
Max.
Resistance at
20OC
Radial
Thickness
of
Insulation
Radial
Thickness
of Sheath
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(mm)
(kg/km)
(A)
1.83
2.17
2.52
2.04
2.27
2.52
2.87
2.50
2.89
2.64
2.97
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40
1.40
1.40
1.50
1.50
1.60
1.60
1.70
1.80
1.90
2.00
2.20
14.00
15.85
17.80
19.80
22.00
24.70
27.70
30.60
34.20
38.00
42.90
541
749
1000
1241
1523
1942
2514
3125
3967
5063
6491
134
171
207
239
262
296
346
394
467
533
611
Product Code
SCSX50.0
SCSX70.0
SCSX95.0
SCSX120.0
SCSX150.0
SCSX185.0
SCSX240.0
SCSX300.0
SCSX400.0
SCSX500.0
SCSX630.0
RAKCAB
APPLICATION
Industrial wiring installations where smoke and acid gas emission would pose a major
hazard in the event of fire. These cables are intended for drawing into trunking and
conduit and are suitable for use in electrical installations such as power, lighting,
appliances, switchgear and controlgear, which are to be used in higher temperature
zones.
HARMONISED CODE
- 0.75mm2 & 1.0mm2 solid conductor wire
- 1.5mm2 & 2.5mm2 solid conductor wire
- 1.5mm2 to 120mm2 stranded conductor wire
CONSTRUCTION
Reference
: 6491B
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: Thermosetting, low smoke zero halogen
STANDARD COLOURS
Colours
: Black, Blue, Red, Yellow, Green/Yellow, Grey
Other colours available on request.
PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden reels of 500m and 1000m
- Customised lengths available on request
TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 450/750V (300/500V for 0.75mm2 & 1.0mm2)
Standards
: Generally to BS7211
RAKCAB
Nominal
CrossSectional
Area
(mm2)
10
H05Z-U
H07Z-U
H07Z-R
0.75
1.00
1.50
1.50
2.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
Conductor
Number of Diameter of
Strands
Strand
1
1
1
7
1
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
91
91
Max.
Resistance
at 20OC
Radial
Thickness
of Insulation
Approx.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(kg/km)
(A)
0.98
1.13
1.38
0.53
1.78
0.67
0.85
1.04
1.35
1.70
2.14
2.52
1.83
2.17
2.52
2.04
2.25
2.52
2.24
2.50
2.85
2.65
2.97
24.50
18.10
12.10
12.10
7.410
7.410
4.610
3.080
1.830
1.150
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.2
2.6
2.8
2.8
2.40
2.60
3.20
3.30
3.90
4.00
4.60
5.20
6.70
7.80
9.70
10.90
12.80
14.60
17.10
18.80
20.90
23.30
26.60
29.60
33.20
36.90
41.10
11
14
21
22
32
35
50
71
120
180
280
380
510
710
970
1200
1480
1900
2480
3100
3940
5000
6350
10
12
16
16
21
21
28
36
50
68
89
110
134
171
207
239
262
296
346
394
467
533
611
Product Code
SCLO0.75
SCLO1.0
SCLO1.5
SCL1.5
SCLO2.5
SCL2.5
SCL4.0
SCL6.0
SCL10.0
SCL16.0
SCL25.0
SCL35.0
SCL50.0
SCL70.0
SCL95.0
SCL120.0
SCL150.0
SCL185.0
SCL240.0
SCL300.0
SCL400.0
SCL500.0
SCL630.0
APPLICATION
These cables are intended for use in fixed installations such as power, lighting, appliances
and switchgear & control panel wiring.
HARMONISED CODE
- 0.5mm2 to 1.0mm2 wire
- 1.5mm2 & 300mm2 stranded conductor wire
H05V2-K
H07V2-K
CONSTRUCTION
Reference
: 2491X HR
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
(Tinned copper conductor available on request)
Insulation
: PVC Type TI 3 to BS7655
STANDARD COLOURS
Colour
: Red, Yellow, Blue, Black, Green, Yellow/Green
Grey, White, Orange, Brown, Violet, Pink, Turquoise
Other colours available on request
PACKAGING
- Sizes 0.75mm2 to 35mm2 in reels/coils of 100yards and 100m
- All sizes can be supplied in non-returnable wooden drums of 500m and 1000m
TECHNICAL DATA
Max. Operating Temperature : Upto 105OC
Rated Voltage
: 600/1000V
Standards
: BS6231
Nominal
CrossSectional
Area
Conductor
Number of Diameter of
Strands
Strand
(mm2)
0.50
0.75
1.00
1.50
2.50
4.00
6.00
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
16
24
32
30
50
56
84
80
126
196
276
396
360
475
608
750
925
1221
Max.
Resistance
at 20OC
Radial
Thickness
of Insulation
Max
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(mm)
(/km)
(mm)
(mm)
(kg/km)
(A)
0.20
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
39.00
26.00
19.50
13.30
7.980
4.950
3.300
1.910
1.210
0.780
0.560
0.390
0.270
0.210
0.160
0.124
0.0991
0.0754
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
3.00
3.10
3.30
3.60
4.10
4.80
5.30
7.20
9.00
11.5
12.50
15.40
17.50
19.20
21.20
23.90
25.90
28.90
13
15
18
24
35
51
70
118
180
280
375
537
728
977
1215
1521
1870
2410
8
10
12
16
21
28
36
50
68
89
110
134
171
207
239
262
296
346
Product Code
PW0.5
PW0.75
PW1.0
PW1.5
PW2.5
PW4.0
PW6.0
PW10.0
PW16.0
PW25.0
PW35.0
PW50.0
PW70.0
PW95.0
PW120.0
PW150.0
PW185.0
PW240.0
RAKCAB
11
APPLICATION
General purpose indoors or outdoors in dry or damp situations. Portable tools, washing
machines, vacuum cleaners, lawn mowers and light domestic applications.
HARMONISED CODE
H05VV-F
CONSTRUCTION
Reference
: 0.5mm2 to 4mm2 - 318-Y and 6.0mm2 to 25mm2 - 638-Y
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI 2 to BS7655
Lay-up
: Cores are twisted
Sheath
: PVC Type TM 2 to BS7655
COLOUR CODING
Cores
: 2-core- Brown, Blue
3-core- Brown, Blue, Green/Yellow
4-core- Brown, Black, Grey, Green/Yellow
5-core- Brown, Black, Grey, Blue, Green/Yellow
Sheath
PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m or non-returnable wooden
drums of 500m and 1000m
TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 0.5mm2 to 4mm2 - 300/500V
6.0mm2 to 25mm2 - 600/1000V
Standards
: BS6500/BS7919
RAKCAB
contd...
12
Number
of
Strands
(mm2)
Radial
Thickness
of
Insulation
Radial
Thickness
of Sheath
Max.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(/km)
(mm)
(mm)
(mm)
(kg/km)
(A)
FX2C0.5
Diameter
of Strand
Max.
Resistance
at 20OC
(mm)
Product Code
0.5
16
0.20
39.00
0.6
0.8
6.8
52
0.75
24
0.20
26.00
0.6
0.8
7.2
63
FX2C0.75
1.0
32
0.20
19.50
0.6
0.8
7.5
73
14
FX2C1.0
1.5
30
0.25
13.30
0.7
0.8
8.6
95
18
FX2C1.5
2.5
50
0.25
7.98
0.8
1.0
10.6
145
24
FX2C2.5
4.0
56
0.30
4.95
0.8
1.1
11.8
190
32
FX2C4.0
6.0
84
0.30
3.30
0.8
1.2
13.1
256
42
FX2C6.0
10.0
80
0.40
1.91
1.0
1.4
16.1
397
55
FX2C10.0
16.0
126
0.40
1.21
1.0
1.4
18.5
596
75
FX2C16.0
25.0
196
0.40
0.78
1.2
1.4
21.6
956
100
FX2C25.0
0.5
16
0.20
39.00
0.6
0.8
7.2
60
FX3C0.5
0.75
24
0.20
26.00
0.6
0.8
7.5
74
FX3C0.75
1.0
32
0.20
19.50
0.6
0.8
8.0
86
14
FX3C1.0
1.5
30
0.25
13.30
0.7
0.9
9.4
120
18
FX3C1.5
2.5
50
0.25
7.98
0.8
1.1
11.4
180
24
FX3C2.5
4.0
56
0.30
4.95
0.8
1.2
12.6
236
32
FX3C4.0
6.0
84
0.30
3.30
0.8
1.4
14.2
344
42
FX3C6.0
10.0
80
0.40
1.91
1.0
1.4
17.1
489
55
FX3C10.0
16.0
126
0.40
1.21
1.0
1.4
19.5
724
75
FX3C16.0
25.0
196
0.40
0.78
1.2
1.6
23.5
1154
100
FX3C25.0
0.5
16
0.20
39.00
0.6
0.8
7.9
72
FX4C0.5
0.75
24
0.20
26.00
0.6
0.8
8.3
83
FX4C0.75
1.0
32
0.20
19.50
0.6
0.9
9.0
101
14
FX4C1.0
1.5
30
0.25
13.30
0.7
1.0
10.5
141
18
FX4C1.5
2.5
50
0.25
7.98
0.8
1.1
12.5
214
24
FX4C2.5
4.0
56
0.30
4.95
0.8
1.4
14.0
286
32
FX4C4.0
6.0
84
0.30
3.30
0.8
1.4
15.5
411
42
FX4C6.0
10.0
80
0.40
1.91
1.0
1.4
18.6
637
55
FX4C10.0
16.0
126
0.40
1.21
1.0
1.4
21.5
988
75
FX4C16.0
25.0
196
0.40
0.78
1.2
1.6
25.7
1453
100
FX4C25.0
0.5
16
0.20
39.00
0.6
0.9
8.6
89
FX5C0.5
0.75
24
0.20
26.00
0.6
0.9
9.2
113
FX5C0.75
1.0
32
0.20
19.50
0.6
0.9
9.6
130
14
FX5C1.0
1.5
30
0.25
13.30
0.7
1.0
11.2
171
18
FX5C1.5
2.5
50
0.25
7.98
0.8
1.2
13.4
265
24
FX5C2.5
4.0
56
0.30
4.95
0.8
1.4
15.4
353
32
FX5C4.0
6.0
84
0.30
3.30
0.8
1.4
16.5
506
42
FX5C6.0
10.0
80
0.40
1.91
1.0
1.4
20.6
815
55
FX5C10.0
16.0
126
0.40
1.21
1.0
1.6
24.0
1202
75
FX5C16.0
25.0
196
0.40
0.78
1.2
1.6
28.6
1818
100
FX5C25.0
RAKCAB
No. of
Cores
13
APPLICATION
General purpose, heat resisting, indoors or outdoors in dry or damp situations. Portable
tools, washing machines, vacuum cleaners, lawn mowers and light domestic applications,
especially in higher temperature zones.
HARMONISED CODE
H05V2V2-F
CONSTRUCTION
Reference
: 0.5mm2 to 4mm2 - 309-Y
Conductor
: Flexible plain copper class 5 to BS6360
Insulation
: PVC Type TI 3 to BS7655
Lay-up
: Cores are twisted
Sheath
: PVC Type TM 3 to BS7655
COLOUR CODING
Cores
: 2-core- Brown, Blue
3-core- Brown, Blue, Green/Yellow
4-core- Brown, Black, Grey, Green/Yellow
5-core- Brown, Black, Grey, Blue, Green/Yellow
Sheath
PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m or non-returnable wooden
drums of 500m and 1000m
TECHNICAL DATA
Max. Operating Temperature : upto 105OC
Rated Voltage
: 0.5mm2 to 4mm2 - 300/500V
6.0mm2 to 25mm2 - 600/1000V
Standards
: BS6500/BS7919 (Previously BS6141)
RAKCAB
contd...
14
Number
of
Strands
(mm2)
Radial
Thickness
of
Insulation
Radial
Thickness
of Sheath
Max.
Overall
Diameter
Approx.
Nett
Weight
Approx.
Current
Carrying
Capacity
(/km)
(mm)
(mm)
(mm)
(kg/km)
(A)
FXHR2C0.5
Diameter
of Strand
Max.
Resistance
at 20OC
(mm)
Product Code
0.5
16
0.20
39.00
0.6
0.8
6.8
52
0.75
24
0.20
26.00
0.6
0.8
7.2
63
FXHR2C0.75
1.0
32
0.20
19.50
0.6
0.8
7.5
73
14
FXHR2C1.0
1.5
30
0.25
13.30
0.7
0.8
8.6
95
18
FXHR2C1.5
2.5
50
0.25
7.98
0.8
1.0
10.6
145
24
FXHR2C2.5
4.0
56
0.30
4.95
0.8
1.1
11.8
190
32
FXHR2C4.0
6.0
84
0.30
3.30
0.8
1.2
13.1
256
42
FXHR2C6.0
10.0
80
0.40
1.91
1.0
1.4
16.1
397
55
FXHR2C10.0
16.0
126
0.40
1.21
1.0
1.4
18.5
596
75
FXHR2C16.0
25.0
196
0.40
0.78
1.2
1.4
21.6
956
100
FXHR2C25.0
0.5
16
0.20
39.00
0.6
0.8
7.2
60
FXHR3C0.5
0.75
24
0.20
26.00
0.6
0.8
7.5
74
FXHR3C0.75
1.0
32
0.20
19.50
0.6
0.8
8.0
86
14
FXHR3C1.0
1.5
30
0.25
13.30
0.7
0.9
9.4
120
18
FXHR3C1.5
2.5
50
0.25
7.98
0.8
1.1
11.4
180
24
FXHR3C2.5
4.0
56
0.30
4.95
0.8
1.2
12.6
236
32
FXHR3C4.0
6.0
84
0.30
3.30
0.8
1.4
14.2
344
42
FXHR3C6.0
10.0
80
0.40
1.91
1.0
1.4
17.1
489
55
FXHR3C10.0
16.0
126
0.40
1.21
1.0
1.4
19.5
724
75
FXHR3C16.0
25.0
196
0.40
0.78
1.2
1.6
23.5
1154
100
FXHR3C25.0
0.5
16
0.20
39.00
0.6
0.8
7.9
72
FXHR4C0.5
0.75
24
0.20
26.00
0.6
0.8
8.3
83
FXHR4C0.75
1.0
32
0.20
19.50
0.6
0.9
9.0
101
14
FXHR4C1.0
1.5
30
0.25
13.30
0.7
1.0
10.5
141
18
FXHR4C1.5
2.5
50
0.25
7.98
0.8
1.1
12.5
214
24
FXHR4C2.5
4.0
56
0.30
4.95
0.8
1.4
14.0
286
32
FXHR4C4.0
6.0
84
0.30
3.30
0.8
1.4
15.5
411
42
FXHR4C6.0
10.0
80
0.40
1.91
1.0
1.4
18.6
637
55
FXHR4C10.0
16.0
126
0.40
1.21
1.0
1.4
21.5
988
75
FXHR4C16.0
25.0
196
0.40
0.78
1.2
1.6
25.7
1453
100
FXHR4C25.0
0.5
16
0.20
39.00
0.6
0.9
8.6
89
FXHR5C0.5
0.75
24
0.20
26.00
0.6
0.9
9.2
113
FXHR5C0.75
1.0
32
0.20
19.50
0.6
0.9
9.6
130
14
FXHR5C1.0
1.5
30
0.25
13.30
0.7
1.0
11.2
171
18
FXHR5C1.5
2.5
50
0.25
7.98
0.8
1.2
13.4
265
24
FXHR5C2.5
4.0
56
0.30
4.95
0.8
1.4
15.4
353
32
FXHR5C4.0
6.0
84
0.30
3.30
0.8
1.4
16.5
506
42
FXHR5C6.0
10.0
80
0.40
1.91
1.0
1.4
20.6
815
55
FXHR5C10.0
16.0
126
0.40
1.21
1.0
1.6
24.0
1202
75
FXHR5C16.0
25.0
196
0.40
0.78
1.2
1.6
28.6
1818
100
FXHR5C25.0
RAKCAB
No. of
Cores
15
HARMONISED CODE
H05VV5-F
CONSTRUCTION
Conductor
: Flexible Plain Copper Class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI2 to BS7655
Lay-up
: Cores twisted together, if necessary, in several concentric layers
Sheath
: PVC Type TM5 to BS7655
STANDARD COLOURS
Colour Coding : Core identification by number coding in accordance with BSEN 50334 and
earth core coloured Green/Yellow
Sheath
: Generally Grey, other colours available on request
PACKAGING
All sizes can be supplied in non-returnable wooden drums of 500m & 1000m
TECHNICAL DATA
Max. Operating Temperature
Rated Voltage
No. of Cores
Specification
:
:
:
:
RAKCAB
70OC
300/500V
6 to 60
Generally to BS6500/BS7919
RAKCAB
contd...
16
Number
of
Strands
(mm2)
Radial
Thickness
of
Insulation
Radial
Thickness
of Sheath
Max.
Overall
Diameter
Approx.
Nett
Weight
(/km)
(mm)
(mm)
(mm)
(kg/km)
Diameter
of Strand
Max.
Resistance
at 20OC
(mm)
Product Code
0.50
16
0.2
39
0.6
0.9
9.6
114
FC6C0.50
0.75
24
0.2
26
0.6
0.9
10.10
139
FC6C0.75
1.00
32
0.2
19.5
0.6
1.0
10.80
173
FC6C1.00
1.50
30
0.25
13.3
0.7
1.1
12.60
240
FC6C1.50
2.50
50
0.25
7.98
0.8
1.2
15.10
357
FC6C2.50
0.50
16
0.2
39
0.6
0.9
10.40
114
FC7C0.50
0.75
24
0.2
26
0.6
1.0
11.30
150
FC7C0.75
1.00
32
0.2
19.5
0.6
1.0
11.80
177
FC7C1.00
1.50
30
0.25
13.3
0.7
1.2
14.10
257
FC7C1.50
2.50
50
0.25
7.98
0.8
1.3
16.80
382
FC7C2.50
12
0.50
16
0.2
39
0.6
1.1
12.90
203
FC12C0.50
12
0.75
24
0.2
26
0.6
1.1
13.70
252
FC12C0.75
12
1.00
32
0.2
19.5
0.6
1.2
14.60
311
FC12C1.00
12
1.50
30
0.25
13.3
0.7
1.3
17.00
432
FC12C1.50
12
2.50
50
0.25
7.98
0.8
1.5
20.60
663
FC12C2.50
18
0.50
16
0.2
39
0.6
1.2
15.30
279
FC18C0.50
18
0.75
24
0.2
26
0.6
1.3
16.40
363
FC18C0.75
18
1.00
32
0.2
19.5
0.6
1.3
17.20
431
FC18C1.00
18
1.50
30
0.25
13.3
0.7
1.5
20.30
618
FC18C1.50
18
2.50
50
0.25
7.98
0.8
1.8
24.80
966
FC18C2.50
27
0.50
16
0.2
39
0.6
1.4
18.60
410
FC27C0.50
27
0.75
24
0.2
26
0.6
1.5
19.90
532
FC27C0.75
27
1.00
32
0.2
19.5
0.6
1.5
21.00
634
FC27C1.00
27
1.50
30
0.25
13.3
0.7
1.8
24.90
924
FC27C1.50
27
2.50
50
0.25
7.98
0.8
2.1
30.20
1430
FC27C2.50
36
0.50
16
0.2
39
0.6
1.5
20.90
516
FC36C0.50
36
0.75
24
0.2
26
0.6
1.6
22.40
679
FC36C0.75
36
1.00
32
0.2
19.5
0.6
1.7
23.80
824
FC36C1.00
36
1.50
30
0.25
13.3
0.7
2.0
28.20
1192
FC36C1.50
36
2.50
50
0.25
7.98
0.8
2.3
34.20
1841
FC36C2.50
48
0.50
16
0.2
39
0.6
1.7
24.30
690
FC48C0.50
48
0.75
24
0.2
26
0.6
1.8
25.90
895
FC48C0.75
48
1.00
32
0.2
19.5
0.6
1.9
27.60
1096
FC48C1.00
48
1.50
30
0.25
13.3
0.7
2.2
32.50
1576
FC48C1.50
48
2.50
50
0.25
7.98
0.8
2.4
39.10
2393
FC48C2.50
60
0.50
16
0.2
39
0.6
1.8
26.60
826
FC60C0.50
60
0.75
24
0.2
26
0.6
2.0
28.70
1098
FC60C0.75
60
1.00
32
0.2
19.5
0.6
2.1
30.50
1343
FC60C1.00
60
1.50
30
0.25
13.3
0.7
2.4
35.80
1923
FC60C1.50
60
2.50
50
0.25
7.98
0.8
2.4
42.60
2848
FC60C2.50
RAKCAB
No. of
Cores
17
APPLICATION
These cables are intended for fixed protected installation inside appliances and in or on
lighting fittings, door bells, spaeaker etc.
CONSTRUCTION
Reference
: 2812X
Conductor
: Flexible plain copper class 5 to BS6360/IEC60228-1
Insulation
: PVC Type TI 2 to BS7655
STANDARD COLOURS
Available in White, Red-Black or transparent PVC. Other colours available on request
PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m/500m/1000m
TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 300V
Standards
: BS6500
Conductor
Nominal
CrossSectional
Area
Maximum
Diameter of
Wire
Max.
Resistance
at 20OC
Radial
Thickness of
Insulator
Max.
Overall
Diameter
Approx.
Nett
Weight
(mm2)
(mm)
(/km)
(mm)
(mm)
(kg/km)
2 x 0.5
2 x 0.75
0.20
0.20
39.00
26.00
0.8
0.8
3.0 x 6.0
3.2 x 6.4
22
28
Product Code
TW2C0.5
TW2C0.75
RAKCAB
18
APPLICATION
For domestic and industrial wiring. Suitable for surface wiring where there is little risk of
mechanical damage.
CONSTRUCTION
Reference
: Twin/three core flat- 619-Y, Twin/three core flat with earth- 624-Y
Conductor
: Solid or stranded plain copper class 1 or 2 to BS6360/IEC60228-1
Insulation
: PVC Type TI 1 or Type 5 to BS6746
Sheath
: PVC Type 6 or 9 to BS6746
contd...
COLOUR CODING
Cores
: 2-core- Red, Black
3-core- Red, Yellow, White
As per New Harmonised code
2-core- Brown, Blue
3-core- Brown, Black, Grey
Sheath
: White, Grey
Other colours available on request
PACKAGING
All sizes can be supplied in reels/coils of 100yards/100m/500m/1000m
TECHNICAL DATA
Max. Operating Temperature : 70OC
Rated Voltage
: 300/500V
Standards
: BS6004
Reference
Number
Conductor
Nominal
CrossSectional
Area
Number of
Strands
(mm2)
6192Y
TWIN
FLAT
6193Y
THREE
CORE
FLAT
6242Y
TWIN
FLAT
WITH
EARTH
6243Y
THREE
CORE
FLAT
WITH
EARTH
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0
1
1
1
7
7
7
7
1
1
1
7
7
7
7
1
1
1
7
7
7
7
1
1
1
7
7
7
7
Diameter
of Strand
Radial
Thickness
of
Insulation
Radial
Thickness
of Sheath
Approx.
Overall
Diameter
Approx.
Nett
Weight
Earth
Continuity
Conductor
Cross
section
(mm)
(mm)
(mm)
(mm)
(kg/km)
(mm2)
1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70
1.13
1.38
1.78
0.85
1.04
1.35
1.70
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.9
0.9
1.0
1.0
1.1
1.2
1.3
4.7x7.4
5.4x8.4
6.2x9.8
7.2x11.5
8.0x13.0
9.6x16.0
11.0x18.5
4.7x9.8
5.4x11.5
6.2x13.5
7.2x16.5
8.0x18.0
9.6x22.5
11.0x26.5
4.7x8.6
5.4x9.6
6.2x11.5
7.2x13.0
8.0x15.0
9.6x19.0
11.0x22.5
4.7x11.0
5.4x12.5
6.2x14.5
7.2x18.0
8.0x20.0
9.6x25.5
11.0x29.5
53
70
105
150
205
320
470
76
100
150
225
300
480
695
68
85
120
175
240
390
560
91
115
170
250
340
540
790
1.0
1.0
1.5
1.5
2.5
4.0
6.0
1.0
1.0
1.5
1.5
2.5
4.0
6.0
Product Code
FLTO2C1.0
FLTO2C1.5
FLTO2C2.5
FLT2C4.0
FLT2C6.0
FLT2C10.0
FLT2C16.0
FLTO3C1.0
FLTO3C1.5
FLTO3C2.5
FLT3C4.0
FLT3C6.0
FLT3C10.0
FLT3C16.0
FLTO2CE1.0
FLTO2CE1.5
FLTO2CE2.5
FLT2CE4.0
FLT2CE6.0
FLT2CE10.0
FLT2CE16.0
FLTO3CE1.0
FLTO3CE1.5
FLTO3CE2.5
FLT3CE4.0
FLT3CE6.0
FLT3CE10.0
FLT3CE16.0
RAKCAB
19
APPLICATION
Industrial wiring and mains distribution. Can be laid direct in the ground, or in ducts,
clipped to surface, on trays or in free air.
CONSTRUCTION
Conductor
: Single, Two, Three, Four and Five core cables. Stranded plain copper
conductors
Insulation
: XLPE insulated, cores laid up, extruded PVC bedding, galvanised steel
wire armoured (Aluminium wires for single cores) and PVC
sheathed.
STANDARD COLOURS
Cores
: Single-core- Red or Black
2-core- Red and Black
3-core- Red, Yellow and Blue
4-core- Red, Yellow, Blue and Black
5-core- Red, Yellow, Blue, Black and Green/Yellow
As per New Harmonised Code
Single-core- Brown or Blue
2-core- Brown and Blue
3-core- Brown, Black and Grey
4-core- Brown, Black Grey and Blue
5-core- Brown, Black, Grey, Green/Yellow and Blue
Sheath Colours : Black. Other colours available on request
TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS5467
RAKCAB
20
Nominal
Area of the
Conductor
Thickness of
Insulation
Thickness
of Extruded
Bedding
Diameter of Thickness of
Armour Wire Outer Sheath
(mm2)
(mm)
(mm)
(mm)
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
800.0
1000.0
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
0.90
1.25
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
Approx
Overall
Diameter
Approx.
Nett
Weight
(mm)
(mm)
(kg/km)
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5
17.5
20.2
22.3
24.2
27.4
30.0
32.8
35.6
40.5
44.2
48.8
55.4
60.6
695
960
1240
1495
1908
2320
2910
3550
4580
5600
7070
10660
13140
Note:
Circular or compacted circular stranded conductor (Class 2)
Product Code
PC1C50
PC1C70
PC1C95
PC1C120
PC1C150
PC1C185
PC1C240
PC1C300
PC1C400
PC1C500
PC1C630
PC1C800
PC1C1000
contd...
Thickness of
Insulation
Thickness
of Extruded
Bedding
Diameter of Thickness of
Armour Wire Outer Sheath
(mm2)
(mm)
(mm)
(mm)
1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
0.90
0.90
0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
2.50
2.50
Approx
Overall
Diameter
Approx.
Nett
Weight
(mm)
(mm)
(kg/km)
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
12.1
13.6
14.7
15.9
18.0
20.4
20.4
23.3
25.8
29.0
33.1
36.1
39.3
44.7
49.0
53.5
59.0
315
380
460
550
795
860
1000
1420
1760
2270
3120
3730
4430
5700
7060
8490
10470
Product Code
PC2C1.5
PC2C2.5
PC2C4.0
PC2C6.0
PC2C10
PC2C16
PC2C25
PC2C35
PC2C50
PC2C70
PC2C95
PC2C120
PC2C150
PC2C185
PC2C240
PC2C300
PC2C400
Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)
Thickness
of Extruded
Bedding
Diameter of Thickness of
Armour Wire Outer Sheath
(mm2)
(mm)
(mm)
(mm)
1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
0.90
0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
Approx
Overall
Diameter
Approx.
Nett
Weight
(mm)
(mm)
(kg/km)
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
12.6
14.1
15.3
16.6
19.5
21.6
23.6
25.7
28.5
32.2
37.0
40.4
45.5
49.8
55.1
60.2
66.6
330
415
505
615
870
1055
1485
1855
2305
3050
4190
5050
6450
7790
9680
11780
14600
Product Code
PC3C1.5
PC3C2.5
PC3C4.0
PC3C6.0
PC3C10
PC3C16
PC3C25
PC3C35
PC3C50
PC3C70
PC3C95
PC3C120
PC3C150
PC3C185
PC3C240
PC3C300
PC3C400
Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)
contd...
RAKCAB
Nominal
Area of the
Conductor
21
Thickness of
Insulation
Thickness
of Extruded
Bedding
Diameter of Thickness of
Armour Wire Outer Sheath
(mm2)
(mm)
(mm)
(mm)
1.5*
2.5*
4.0*
6.0*
10.0*
16.0*
25.0~
35.0~
50.0~
70.0~
95.0~
120.0~
150.0~
185.0~
240.0~
300.0~
400.0~
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
0.90
0.90
0.90
1.25
1.25
1.25
1.60
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
Approx
Overall
Diameter
Approx.
Nett
Weight
(mm)
(mm)
(kg/km)
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
3.2
13.3
15.0
16.4
18.7
21.1
23.4
26.1
28.6
32.0
37.7
41.7
47.1
51.4
56.6
63.0
68.8
78.1
345
440
540
780
1125
1300
1860
2335
2960
4200
5400
6990
8300
10076
12660
15350
19880
Product Code
PC4C1.5
PC4C2.5
PC4C4.0
PC4C6.0
PC4C10
PC4C16
PC4C25
PC4C35
PC4C50
PC4C70
PC4C95
PC4C120
PC4C150
PC4C185
PC4C240
PC4C300
PC4C400
Note:
* Circular or compacted circular stranded conductor (Class 2)
~ Shaped standard conductor (Class 2)
Thickness of
Insulation
Thickness
of Extruded
Bedding
Diameter of Thickness of
Armour Wire Outer Sheath
(mm2)
(mm)
(mm)
(mm)
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
0.90
0.90
0.90
1.25
1.25
1.60
1.60
1.60
2.00
2.00
Approx
Overall
Diameter
Approx.
Nett
Weight
(mm)
(mm)
(kg/km)
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.2
14.3
16.1
17.8
20.0
22.9
26.6
31.5
34.8
40.4
46.3
430
545
680
840
1105
1450
2245
2840
3895
5145
Product Code
PC5C1.5
PC5C2.5
PC5C4.0
PC5C6.0
PC5C10
PC5C16
PC5C25
PC5C35
PC5C50
PC5C70
RAKCAB
Note:
Circular or compacted circular stranded conductor (Class 2)
22
contd...
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
In Air
Single Core in Trefoil
Unarmoured
Armoured
22
30
39
49
67
92
123
146
174
222
275
321
371
430
513
594
692
801
925
1051
1172
Operating conditions
22
30
39
49
67
92
123
146
180
230
282
328
377
433
510
581
664
751
846
919
997
:
:
:
:
In Ground
In Duct (A)
Voltage Drop of 3
Single Core in Trefoil Single Core in Trefoil Single core cables Trefoil
Armoured
Armoured
(V/A/km)
28
38
49
62
82
108
139
165
199
244
292
332
371
417
480
536
594
658
723
764
810
26
35
46
59
78
101
134
154
199
239
281
315
341
376
421
459
488
529
571
595
632
26.7
16.4
10.2
6.80
4.00
2.50
1.62
1.17
0.88
0.62
0.46
0.38
0.32
0.28
0.23
0.21
0.20
0.18
0.17
0.16
0.15
50OC
35OC
0.50m
1.2 Km/W
contd...
RAKCAB
Area
23
Area
(mm2)
Unarmoured
Armoured
In Ground
Armoured
In Duct (A)
Armoured
Voltage Drop
(V/A/km)
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
22
30
39
50
67
97
122
151
183
232
287
335
383
444
529
611
711
24
32
43
55
74
98
128
158
190
239
295
341
289
449
530
605
696
33
42
56
70
94
121
157
188
223
273
328
372
417
470
544
609
687
27
35
46
58
77
99
127
153
181
224
269
307
345
391
453
509
575
30.9
18.9
11.8
7.90
4.70
2.90
1.90
1.35
1.00
0.70
0.52
0.42
0.35
0.90
0.24
0.21
0.20
Operating conditions
:
:
:
:
50OC
35OC
0.50m
1.2 Km/W
RAKCAB
24
In Air
Area
(mm2)
Unarmoured
Armoured
In Ground
Armoured
In Duct (A)
Armoured
Voltage Drop
(V/A/km)
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
19
27
34
44
58
83
105
129
157
200
246
288
330
381
454
524
608
20
27
37
46
64
83
109
134
163
205
253
293
335
386
456
519
597
28
36
47
59
79
102
131
157
187
229
274
312
349
394
455
509
574
22
29
39
48
65
83
107
128
152
187
226
258
291
329
380
427
490
26.7
16.4
10.2
6.80
4.00
2.50
1.65
1.15
0.87
0.60
0.45
0.37
0.30
0.26
0.21
0.19
0.17
Operating conditions
:
:
:
:
50OC
35OC
0.50m
1.2 Km/W
APPLICATION
Industrial wiring for remote control and telemetry circuits etc. Can be laid direct in
the ground, or in ducts, clipped to surface, on trays or in free air.
CONSTRUCTION
Multi-core cables. Stranded plain copper conductors, XLPE insulated, cores laid up,
extruded PVC bedding, galvanised steel wire armoured and PVC sheathed.
STANDARD COLOURS
Cores
: White with Black numerals
Sheath Colours : Black. Other colours available on request
TECHNICAL DATA
Max. Operating Temperature : 90OC
Rated Voltage
: 600/1000V
Standards
: BS5467
12
19
27
37
48
Nominal Area
of Conductor
Approx.
Dia. under
Armour
Approx. Dia.
over Armour
Approx.
Overall
Diameter
Approx
Net
Weight
(mm2)
(mm)
(mm)
(mm)
(kg/km)
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
1.5
2.5
4.0
10.2
12.3
14.0
13.7
16.3
19.1
16.2
19.9
22.5
20.0
24.0
27.5
22.3
26.9
31.0
25.4
31.0
35.3
12.1
14.1
16.5
16.2
18.8
22.2
18.7
23.1
25.7
23.2
27.2
30.7
25.5
30.1
35.0
28.6
35.0
39.3
15.2
17.1
19.7
19.4
22.4
25.7
22.2
26.6
29.3
26.7
30.7
34.4
29.0
33.8
39.2
32.7
39.3
44.1
470
600
890
780
1000
1410
1000
1540
1830
1500
1950
2500
1800
2350
3100
2050
3100
4100
Product Code
AX7C1.5
AX7C2.5
AX7C4.0
AX12C1.5
AX12C2.5
AX12C4.0
AX19C1.5
AX19C2.5
AX19C4.0
AX27C1.5
AX27C2.5
AX27C4.0
AX37C1.5
AX37C2.5
AX37C4.0
AX48C1.5
AX48C2.5
AX48C4.0
RAKCAB
Number of
Cores
25
TELECOMMUNICATION
DATA & INSTRUMENTATION
CABLES
APPLICATION
Internal telephone cables generally conform to British & International Telecommunications authorities
specifications.
Type 1308 cable has each individual core of a different bi-colour for easy identification. In the color coding tables
the first color is that of the PVC insulation and the second is the stripe color.
These cables are suitable for cross connecting individual items of switchboard equipments, and are used where
an external telephone cable is to be connected to many internal distribution points - in a large block of flats or
in a small commercial premises not equipped with private exchanges. These cables are ideal for direct
connection on to terminal blocks.
CONSTRUCTION
Cable Type : Cu/PVC/PVC
Conductor : Solid plain/tinned copper wire to BS4109.
Insulation : PVC to BS6746.
Lay-up
: In full units of 16,20,30 pairs sub-units of 8,10,15 pairs - each unit identified by a different
colored lapping tape; units are laid up together to form a compact circular cable
Wrapping : Polyester clear tape.
Sheath
: PVC (Cream, white, grey or black) to BS6746. Fitted with a nylon ripcord for easy stripping.
RAKCAB
No. of
Pairs
28
0.5mm
No. of
Cores
A-Wire
Insul.
BLU
B-Wire
Insul.
BLU
Insul.
Res.
(/km)
(M/
km)
(PF)500M
(kg/km)
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
(mm2)
(mm)
(mm)
(mm)
(mm)
WHI
No. of
Pairs
WHI
0.2
0.2
0.9
0.6
3.5
97.8
50
500
18
TI5002
1
2
0.2
0.2
0.9
0.7
4.3
97.8
50
500
27
TI5003
WHI BRN
BRN WHI
0.2
0.2
0.9
0.7
4.7
97.8
50
500
33
TI5004
10
WHI
GRY
GRY
WHI
0.2
0.2
0.9
0.7
5.1
97.8
50
500
39
TI5005
12
RED
BLU
BLU
RED
0.2
0.2
0.9
0.7
5.5
97.8
50
500
45
TI5006
14
16
0.2
0.2
0.9
0.7
6.1
97.8
50
500
57
TI5008
18
RED
BRN
BRN
RED
10
20
RED
GRY
GRY
RED
0.2
0.2
0.9
0.7
6.6
97.8
50
500
69
TI5010
10
11
22
BLK
BLU
BLU
BLK
12
24
BLK
ORG ORG
BLK
0.2
0.2
0.9
0.8
7.3
97.8
50
500
83
TI5012
13
26
BLK
GRN GRN
BLK
14
28
BLK
BRN
BRN
BLK
15
30
BLK
GRY
GRY
BLK
16
32
YEL
BLU
BLU
YEL
16
17
34
YEL
ORG ORG
YEL
17
18
36
YEL
GRN GRN
YEL
18
19
38
YEL
BRN
BRN
YEL
20
40
YEL
GRY
GRY
YEL
21
42
VIO
BLU
BLU
VIO
21
22
44
VIO
ORG ORG
VIO
22
23
46
VIO
GRN GRN
VIO
23
24
48
VIO
BRN
BRN
VIO
25
50
VIO
GRY
GRY
VIO
26
52
PNK
BLU
BLU
PNK
26
27
54
27
28
56
28
29
58
PNK
BRN
BRN
PNK
30
60
PNK
GRY
GRY
PNK
7
9
11
12
13
14
0.2
0.2
0.9
0.8
8.0
97.8
50
500
100
TI5015
15
19
0.2
0.2
0.9
0.9
9.2
97.8
50
500
133
TI5020
20
24
0.2
0.2
0.9
0.9
10.1
97.8
50
500
162
TI5025
25
29
0.2
0.2
0.9
1.0
11.1
97.8
50
500
194
TI5030
30
40
Unit construction cables (Laid up in 10 and 20 pair units as per above color coding.)
40
80
0.2
0.2
0.9
1.0
12.5
97.8
50
500
249
TI5040
50
100
0.2
0.2
0.9
1.2
14.1
97.8
50
500
316
TI5050
50
100
200
0.2
0.2
0.9
1.6
19.7
97.8
50
500
622
TI5100
100
200
400
0.2
0.2
0.9
1.8
27.0
97.8
50
500
1181
TI5200
200
0.5mm
APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.
CONSTRUCTION
Conductor : Plain anealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen
No. of
Pairs
No. of
Cores
A-Wire
Insul.
B-Wire
Insul.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
(mm2)
(mm)
(mm)
(mm)
(mm)
(/km)
Insul.
Res.
(M/
km)
(PF)500M
No. of
Pairs
(kg/km)
WHI
BLU
WHI
ORG
WHI
GRN
WHI
BRN
10
WHI
GRY
12
RED
BLU
14
RED
ORG
16
RED
GRN
18
RED
BRN
10
20
RED
GRY
4
0.2
0.2
0.9
1.1
12.5
91
1500
275
62
TE5005
9
0.2
0.2
0.9
1.1
14.5
91
1500
275
103
TE5010
10
Cables over 10 pair are constructed with 10 pair units with above color coding
20
40
0.2
0.2
0.9
1.2
13.5
91
1500
275
168
TE5020
20
30
60
0.2
0.2
0.9
1.2
15.5
91
1500
275
230
TE5030
30
50
100
0.2
0.2
0.9
1.3
18.0
91
1500
275
333
TE5050
50
100
200
0.2
0.2
0.9
1.4
23.5
91
1500
275
591
TE5100
100
Unit 1
BLU
Unit 2
ORG
Unit 3
GRN
Unit 4
BRN
Unit 5
GRY
Unit 6
WHI
Unit 7
RED
Unit 8
BLK
Unit 9
YEL
Unit 10
VIO
RAKCAB
29
0.63mm
APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.
CONSTRUCTION
Conductor : Plain annealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen
No. of
Pairs
No. of
Cores
A-Wire
Insul.
B-Wire
Insul.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
Insul.
Res.
(mm2)
(mm)
(mm)
(mm)
(mm)
(/km)
(M/
km)
(PF)500M
(kg/km)
0.31
0.25
1.15
1.1
9.5
60
1500
800
41
No. of
Pairs
WHI
BLU
WHI
ORG
WHI
GRN
WHI
BRN
10
WHI
GRY
12
RED
BLU
14
RED
ORG
16
RED
GRN
18
RED
BRN
10
20
RED
GRY
TE6002
2
3
4
0.31
0.25
1.15
1.1
11.0
60
1500
275
90
TE6005
9
0.31
0.25
1.15
1.2
13.0
60
1500
275
145
TE6010
10
Cables over 10 pair are constructed with 10 pair units with above color coding
20
40
0.31
0.25
1.15
1.2
15.5
60
1500
275
242
TE6020
20
30
60
0.31
0.25
1.15
1.3
18.0
60
1500
275
310
TE6030
30
50
100
0.31
0.25
1.15
1.4
22.0
60
1500
275
489
TE6050
50
100
200
0.31
0.25
1.15
1.6
27.5
60
1500
275
850
TE6100
100
RAKCAB
30
Unit 1
BLU
Unit 2
ORG
Unit 3
GRN
Unit 4
BRN
Unit 5
GRY
Unit 6
WHI
Unit 7
RED
Unit 8
BLK
Unit 9
YEL
Unit 10
VIO
0.9mm
APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.
CONSTRUCTION
Conductor : Plain anealed copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Filling
: Cable filled with Petroleum-Jelly
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with laminated aluminium/polyester tape
Sheath
: Polyethylene to BS6234 (Black)
Options
: Without Petroleum-Jelly filling. Without screen
No. of
Pairs
No. of
Cores
A-Wire
Insul.
B-Wire
Insul.
Insul.
Res.
(/km)
(M/
km)
(PF)500M
(kg/km)
30
1500
800
60
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
(mm2)
(mm)
(mm)
(mm)
(mm)
0.64
0.3
1.5
1.1
10.5
No. of
Pairs
WHI
BLU
WHI
ORG
WHI
GRN
WHI
BRN
10
WHI
GRY
12
RED
BLU
14
RED
ORG
16
RED
GRN
18
RED
BRN
10
20
RED
GRY
TE9002
2
3
4
0.64
0.3
1.5
1.2
13.0
30
1500
275
121
TE9005
9
0.64
0.3
1.5
1.2
15.5
30
1500
275
231
TE9010
10
Cables over 10 pair are constructed with 10 pair units with above color coding
20
40
0.64
0.3
1.5
1.3
19.5
30
1500
275
417
TE9020
20
30
60
0.64
0.3
1.5
1.5
24.0
30
1500
275
563
TE9030
30
50
100
0.64
0.3
1.5
1.5
28.0
30
1500
275
896
TE9050
50
100
200
0.64
0.3
1.5
1.7
36
30
1500
275
1650
TE9100
100
Unit 1
BLU
Unit 2
ORG
Unit 3
GRN
Unit 4
BRN
Unit 5
GRY
Unit 6
WHI
Unit 7
RED
Unit 8
BLK
Unit 9
YEL
Unit 10
VIO
RAKCAB
31
APPLICATION
External grade cable for installation in local network distribution systems. These are manufactured generally to
CW1128/CW1179.
CONSTRUCTION
The construction of the external telephone cable shall be to the relevant BT specification and shall have:
Armour
: Suitable number of galvanised mild steel wires, to comply with BS1442, applied directly over
the sheath
Oversheath : The wire armoured cable shall be oversheathed with an extrusion of Polyethylene (Black).
If specially ordered the oversheath can be of PVC compound.
RAKCAB
32
Diameter of
Armour Wire
Nominal
Thickness of
Oversheath
Minimum
Increase in
Cable Dia. Due To
Armour &
Oversheath
Maximum
(mm)
(mm)
(mm)
(mm)
(mm)
12
0.90
0.9
5.2
12.1
15
1.25
0.9
5.9
15.1
20
1.60
1.0
6.8
20.1
25
1.60
1.1
7.0
25.1
30
2.00
1.2
8.0
30.1
35
2.00
1.3
8.2
35.1
40
2.00
1.4
8.4
40.1
45
2.50
1.5
9.6
45.1
50
2.50
1.6
9.8
50.1
55
2.50
1.7
10.0
55.1
60
2.50
1.8
10.2
60.1
65
3.15
1.9
11.7
65.1
70
3.15
2.0
11.9
70.1
3.15
2.1
12.1
0.65mm
APPLICATION
External grade cable for data transmission and local network distribution systems.
CONSTRUCTION
Conductor : Solid, plain copper wire to BS4109
Insulation : Solid or cellular Polyethylene to BS6234
Lay-up
: Cores twisted into pairs and cross stranded to form units/sub units. These are laid up to form
compact circular cable
Wrapping : Cable lapped longitudinally with polyester or paper tape
Screen
: Cable screened with aluminium/copper tape
Sheath
: PVC to BS6746 (Black)
No. of
Pairs
No. of
Cores
A-Wire
Insul.
B-Wire
Insul.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
(mm2)
(mm)
(mm)
(mm)
(mm)
(/km)
Insul.
Res.
(M/
km)
(PF)500M
No. of
Pairs
(kg/km)
WHI
BLU
WHI
ORG
0.33
0.24
1.13
1.5
7.15
56
10000 150
58
TL6002
1
2
WHI
GRN
0.33
0.24
1.13
1.5
7.25
56
10000 150
68
TL6003
WHI
BRN
10
WHI
GRY
0.33
0.24
1.13
1.5
9.76
56
10000 150
105
TL6005
12
RED
BLU
0.33
0.24
1.13
1.5
9.76
56
10000 150
130
TL6006
14
RED
ORG
16
RED
GRN
18
RED
BRN
10
20
RED
GRY
9
0.33
0.24
1.13
1.5
11.55
56
10000 150
158
TL6010
10
Cables over 10 pair are constructed with 10 pair units with above color coding
20
40
0.33
0.24
1.13
1.5
14.07
56
10000 150
252
TL6020
20
30
60
0.33
0.24
1.13
1.5
15.96
56
10000 150
347
TL6030
30
40
80
0.33
0.24
1.13
1.5
17.75
56
10000 150
420
TL6040
40
50
100
0.33
0.24
1.13
1.7
19.32
56
10000 150
515
TL6050
50
60
120
0.33
0.24
1.13
1.7
20.07
56
10000 150
599
TL6060
60
70
140
0.33
0.24
1.13
1.7
22.05
56
10000 150
683
TL6070
70
100
200
0.33
0.24
1.13
1.7
25.50
56
10000 150
903
TL6100
100
Unit 1
BLU
Unit 2
ORG
Unit 3
GRN
Unit 4
BRN
Unit 5
GRY
Unit 6
WHI
Unit 7
RED
Unit 8
BLK
Unit 9
YEL
Unit 10
VIO
RAKCAB
33
Drop Wires
0.81mm
APPLICATION
Dropwire No.6 is used for the connection of subscriber's distribution points to the external, overhead
distribution point.
CONSTRUCTION
Conductor : Copper covered steel wire to BS4807
Insulation : PVC to BS6746 (Black or Grey)
No. of
Pairs
No. of
Cores
Insul.
Res.
(/km)
(M/
km)
(kg/km)
122
50
15
Cond.
Area
(mm2)
(mm)
0.52
0.76
(mm)
2.5
x 5.4
DW8108
No. of
Pairs
5.4 mm
0.5 mm
2.5 mm
Drop Wires
APPLICATION
This drop wire is used for overhead distribution to the subcribers installation.
CONSTRUCTION
Conductor : Plain annealed copper wire to BS4109
Insulation : PVC (Black)
Cabling
: Two copper conductors of the drop wire and fibre glass roving of suitable dimensions shall be
insulated with PVC compound extruded over the fibre glass roving integral with the conductor
wires to form a cross-section of the shape as given below
No. of
Pairs
RAKCAB
34
0.5mm
No. of
Cores
Insul.
Res.
(/km)
(M/
km)
(kg/km)
91
20
15
Cond.
Area
(mm2)
(mm)
0.2
0.4
(mm)
2.5
x 5.4
DW50F1
No. of
Pairs
0.4 mm OR MORE
THICK PVC INSULATION
IDENTIFICATION
FIN
WEB
1.4-1.6
1.3
2.2-2.4
0.5
CONSTRUCTION
Conductor : Solid tinned copper wire to BS4109
Insulation : PVC to BS6746
No. of
Cores
Cond.
Dia.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
Cond.
Res. at
20OC
Insul.
Res.
(mm)
(mm2)
(mm)
(mm)
(/km)
(M/
km)
(kg/km)
0.4
0.13
0.25
1.0
153
50
3.43
JW4002
0.5
0.20
0.25
1.1
98
50
5.45
JW5002
0.6
0.28
0.25
1.2
68
50
7.40
JW6002
SOLID CONDUCTORS
CONSTRUCTION
Conductor : Solid tinned copper wire to BS4109
Insulation : PVC to BS6746
Options
: Single or bi-colours
No. of
Cores
Insul.
Res.
(/km)
(M/
km)
(kg/km)
0.85
150
50
1.65
ES4001
0.2
0.95
65
50
2.4
ES5001
0.28
0.2
1.05
65
50
3.2
ES6001
0.64
0.25
1.6
29
50
7.0
ES9001
Cond.
Dia.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
Cond.
Res. at
20OC
(mm)
(mm2)
(mm)
(mm)
0.4
0.126
0.2
0.5
0.20
0.6
0.9
STRANDED CONDUCTORS
CONSTRUCTION
Conductor : Solid tinned copper wire to BS6360
Insulation : PVC to BS6746
Options
: Single or bi-colours
Cond.
Insul.
Res.
Cond.
Area
Cond.
Insul.
R/T
Core
Dia.
Approx.
OD
Cond.
Res. at
20OC
(mm2)
(mm)
(mm)
(mm)
(/km)
(M/
km)
7x
0.2mm
0.22
0.30
1.20
1.2
83
50
16x
0.2mm
0.50
0.45
1.85
1.81
40
50
Rating Weight
PART NO.
(kg/km)
220/
1A
220/
2.5A
5.5
EF7201
7.5
EF16201
RAKCAB
35
Data Cables
Cat 5E
Conductor 1
Conductor 2
Blue
White / Blue
Orange
White / Orange
Green
White / Green
Brown
White / Brown
CONNECTION SYSTEMS
Compatible with all common systems according to EN 50173, ISO/IEC 11801 and TIA/EIA 568-B.
ELECTRICAL PROPERTIES
Conductor Resistance : < 9.38 /100m
Mutual Capacitance
: < 5.6 nF/100m
Resistance Unbalance : 3% maximum
Capacitance Unbalance : 330 pF/km
Delay Skew
: < 45 ns
NVP
: 68%
MECHANICAL PROPERTIES
Bending Radius
During Installation : > 42 mm
After Installation
: > 21 mm
Pulling Force
: < 65 N
Temperature Range : -15C +/-70C
Heat of Combustion : 373 MJ/km
RAKCAB
PACKAGING
Available in easy-pull boxes (305m) or non-returnable reels of longer lengths.
36
Frequency
Attenuation
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return Loss
(Mhz)
(db/100m)
(db/100m)
(db/100m)
(db/100m)
(db/100m)
(db)
0.77
1.8
67.0
64.0
66.0
63.0
1.00
2.0
65.3
62.3
63.8
60.8
20.0
4.00
4.1
56.3
53.3
51.7
48.7
23.0
8.00
5.8
51.8
48.8
45.7
42.7
24.5
10.00
6.5
50.3
47.3
43.8
40.8
25.0
16.00
8.2
47.3
44.3
39.7
36.7
25.0
20.00
9.3
45.8
42.8
37.7
34.7
25.0
25.00
10.4
44.3
41.3
35.8
32.8
24.3
31.25
11.7
42.9
39.9
33.9
30.9
23.6
62.50
17.0
38.4
35.4
27.8
24.8
21.5
100.00
22.0
35.3
32.3
23.8
20.8
20.0
Data Cables
Cat 6
Conductor 1
Conductor 2
Blue
White / Blue
Orange
White / Orange
Green
White / Green
Brown
White / Brown
CONNECTION SYSTEMS
Compatible with all common systems according to EN 50173, ISO/IEC 11801 and TIA/EIA 568-B.
ELECTRICAL PROPERTIES
Conductor Resistance : 141 /100m
Mutual Capacitance
: 49 pF/km (nom.)
Resistance Unbalance : 2% maximum
Capacitance Unbalance : 1600 pF/km
Delay Skew
: 400 ns/km
NVP
: 68%
MECHANICAL PROPERTIES
Bending Radius
During Installation : 8xD
After Installation
: 4xD
Pulling Force
: 100 N
Temperature Range : -15C +60C
Heat of Combustion : 373 MJ/km
Frequency
Attenuation
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return Loss
(Mhz)
(db/100m)
(db/100m)
(db/100m)
(db/100m)
(db/100m)
(db)
1.0
2.0
74.3
72.3
67.8
64.8
20.0
4.0
3.8
65.3
63.3
55.8
52.8
23.0
8.0
5.3
60.8
58.8
49.7
46.7
24.5
10.0
6.0
59.3
57.3
47.8
44.8
25.0
16.0
7.6
56.2
54.2
43.7
40.7
25.0
20.0
8.5
54.8
52.8
41.8
38.8
25.0
25.0
9.5
53.3
51.3
39.8
36.8
24.3
31.25
10.7
51.9
49.9
37.9
34.9
23.6
62.5
15.4
47.4
54.4
31.9
28.9
21.5
100.0
19.8
44.3
42.3
27.8
24.8
20.1
200.0
29.0
39.8
37.8
21.8
18.8
18.0
250.0
32.8
38.3
36.3
19.8
16.8
17.3
SuperLAN
HIGH PERFORMANCE DATA CABLES
RAKCAB
PACKAGING
Available in easy-pull boxes (305m) or non-returnable reels of longer lengths.
37
Instrumentation Cables
MULTIPAIR / MULTICORE INSTRUMENTATION CABLES
Generally to BS5308 Parts 1 & 2
INSTRUMENTATION CABLES -generally to BS5308
Conforming to British Standard Authorities specifications, instrumentation cables are
suitable for computer-controlled electrical and electronic equipment.
PART 1 - POLYETHYLENE INSULATED
CONSTRUCTION
Conductor
Insulation
Voltage
Pair Identification
Binder Tape
Collective Screen
Outer Protection
RAKCAB
Note: These cables are not for direct connection to public mains electricity supply.
38
RAS AL KHAIMAH
Cables FZC
P O Box: 10559, RAK Free Trade Zone
Ras-Al-Khaimah, United Arab Emirates.
Tel: + 971 7 266 0013
Fax: + 971 7 266 0014
E-mail: info@rakcables.com
www.rakcables.com