Vous êtes sur la page 1sur 17

Code No.

337
Roll No.
Total No. of Questions : 30 ]

[ Total No. of Printed Pages : 16

SERIES : 12th (VOC)


BOILER ATTENDANT
SPECIFIED BOILER OPERATIONS THEORY II

[ Hindi and English Medium ]


Evening Session
SEMESTER I (Objective Type)
(Only for Re-appear Candidates)
1

Time allowed : 1 2 hours ]

[ Maximum Marks : 75

bl iz'u-i= esa 30 cgqoSdfYid iz'u fn;s x;s gSaA izR;sd iz'u

2 21

vad dk

gSA lHkh iz'u vfuok;Z gSaA


This Question Paper contains 30 multiple choice questions
carrying 2 21 marks each. All the questions are compulsory.

fn;s x;s 4 fodYiksa

(A), (B), (C)

vkSj (D) esa ls ijh{kkFkhZ dks izR;sd iz'u ds mkj


ds fy, lokZf/kd mi;qDr dsoy ,d gh fodYi pquuk gSA

From the given 4 alternatives (A), (B), (C) and (D) the candidate
has to select only one most appropriate alternative for each
question.

mkj i=d vks0 ,e0 vkj0 ij fooj.k fy[kus / mkj nsus ds fy, dsoy

dkys / uhys ckWy ikWbUV isu dk iz;ksx djsaA


Use Black/Blue ball point pen only to write details/mark answers on
the answer sheet.
337

P. T. O.

(2)

337

d`i;k tkp dj ysa fd bl iz'u-i= esa eqfnzr i`"B 16 rFkk 'u 30 gSaA
Please make sure that the printed pages in this question paper
are 16 in number and it contains 30 questions.

iz'u-i= esa nkfgus gkFk dh vksj fn;s x;s dksM uEcj dks Nk= vks0 ,e0 vkj0

ij fy[ksaA
The Code No. on the right side of the question paper should be
written by the candidate on the O. M. R. Sheet.

,sls mkj ftUgsa dkVk ;k cnyk x;k gS] fujLr dj fn;s tk,xsA
Answer with cutting and overwriting will be cancelled.

ijh{kkFkhZ mkj i=d vks0 ,e0 vkj0 ij viuk vuqekad vadksa ds lkFk-lkFk xksys

esa Hkh HkjsaA


The candidate should fill his/her Roll No. with figures in the
appropriate circles of the O. M. R. Sheet.

ijh{kkFkhZ viuk jksy ua0 iz'u&i= ij vo'; fy[ksaA


Candidate must write their roll number on the question paper.

d`i;k iz'uksa dk mkj nsus lss iwoZ ;g lqfuf'pr dj ysa fd iz'u-i= iw.kZ o lgh

gS] ijh{kk ds mijkUr bl lEcU/k esa dksbZ Hkh nkok Lohdkj ugha fd;k
tk;sxkA
Before answering the question, ensure that you have been
supplied the correct and complete question paper, no claim in
this regard will be entertained after examination.
1. Economiser esa

337

FkekZehVj dk D;k dke gS

(A)

LVhe dk rkieku c<+kus ds fy;s

(B)

ikuh dk rkieku tkuus ds fy,

(C)

LVhe dk izS'kj tkuus ds fy;s

337

(3)
(D)

dksbZ ugha

What is the use of thermometer in the economiser


(A) To increase temperature of steam
(B) To determine the temperature of water
(C) To determine pressure of steam
(D) None of these

2.

bdksuksekbtj dh V~;wcl dh lQkbZ dSls dh tkrh gS


(A)

diM+s }kjk

(B)

LsilZ }kjk

(C)

,;j izS'kj }kjk

(D)

dksbZ ugha

How does economiser tubes cleaned

3.

(A) By cloth

(B) By scrappers

(C) By air pressure

(D) None of these

xzhul bdksuksekbtj esa fdrus gSMj gksrs gSa


(A)

337

rhu

(B)

pkj
P. T. O.

337

(4)

(C)

nks

(D)

dksbZ ugha

How many headers are in Green's economiser

4.

(A) Three

(B) Four

(C) Two

(D) None of these

gSMjl ds chp D;k fQV gksrk gS


(A)

,;j ghVj

(B)

lsVh okYo

(C)

oVhZdy V~;wcl

(D)

dksbZ ugha

What is fitted in between headers

5.

(A) Air heater

(B) Safety valve

(C) Vertical Tubes

(D) None of them

xzhul bdksuksekbtj dks fdl ckW;yj ij yxkrs gSa


(A)

337

yadk'kk;j ckW;yj

(B)

oVhZdy ckW;yj

337

(5)

(C)

esfju ckW;yj

(D)

dksbZ ugha

On which boiler Green's economiser is installed

6.

(A) Lancashire Boiler

(B) Vertical Boiler

(C) Marine Boiler

(D) None of these

bdksuksekbtj dks;ys dh cpr djrk gS


(A) 25 ls 30%

(B) 10 ls 15%

(C) 20 ls 25%

(D)

dksbZ ugha

Economiser saves coal consumption .............

7.

(A) 25 to 30%

(B) 10 to 15%

(C) 20 to 25%

(D) None of these

bdksuksekbtj dk ghfVax ljQsl gksrk gS


(A)

337

oVhZdy V~;wcl

(B)

gksfjt+ksVy V~;wcl
P. T. O.

337

(6)

(C)

nksuksa gSMj

(D)

dksbZ ugha

Heating surface of Economiser is .............

8.

(A) Vertical tubes

(B) Horizontal tubes

(C) Both headers

(D) None of these

bdksuksekbtj esa ikuh izos'k djrk gS


(A)

buySV okYo ls

(B)

bXtkWLV okYo ls

(C)

vkmVySV okYo ls

(D)

dksbZ ugha

The water enters into the ecnomiser through ..............

9.

(A) Inlet valve

(B) Exhaust valve

(C) Out let valve

(D) None of these

bdksuksekbtj }kjk ckW;yj dks ikuh nsus ls ikuh dk ljD;wys'ku -------(A)

337

fLFkj jgrk gS

(B)

c<+rk gS

337

(7)

(C)

(D)

?kVrk gS

lHkh

Feeding water by the economiser into boiler, the


circulation of water becomes ................

10.

(A) Remaining Constant

(B) Increase

(C) Less

(D) None of these

bdksuksekbtj de djrk gS
(A)

FkeZy LVSl

(B)

ikuh

(C)

izS'kj dks

(D)

dksbZ ugha

The economiser reduces .................

11.

(A) Thermal stress

(B) Water

(C) Pressure

(D) None of these

gok iwoZ rkid fdrus fMxzh lsfYl;l gok dk rkieku c<+k nsrk gS
(A) 60 C

337

(B) 40 C

(C) 10 C

(D) 20 C

P. T. O.

337

(8)

How much temperature of air increase by the air pre-heater


(A) 60 C

12.

(B) 40 C

(C) 10 C

(D) 20 C

gok iwoZ rkid ckW;yj dh n{krk fdrus izfr'kr c<+krk gS


(A) 7%

(B) 2%

(C) 4%

(D) 5%

How much percentage of efficiency of boiler is increased


by the air pre-heater
(A) 7%

13.

(B) 2%

(C) 4%

(D) 5%

gok iwoZ rkid ds iz;ksx ls ok;qe.Myh; iznw"k.k gksrk gS


(A)

fLFkj

(B)

de

(C)

T;knk

(D)

dksbZ ugha

By the use of air pre-heater air pollution becomes

14.
337

(A) Constant

(B) Less

(C) More

(D) None of these

fjtsujsfVo VkbZi iwoZ gok rkid esa eksVj }kjk pykbZ xbZ 'kkWV ds pDdj

337

(9)

fdrus gksrs gSa


(A) 3 ls 4 R. P. M.

(B) 6 ls 7 R. P. M.

(C) 5 ls 6 R. P. M.

(D)

dksbZ ugha

R. P. M. of shaft driven by the electric motor in the Regenerative type air pre-heater are .................

15.

(A) 3 to 4 R. P. M.

(B) 6 to 7 R. P. M.

(C) 5 to 6 R. P. M.

(D) None of these

iwoZ rkid dk iz;ksx djuk T;knk mfpr gS ------------(A)

lkekU; Hkki IykaV esa

(B)

cM+s Hkki IykaV esa

(C)

NksVs Hkki IykaV esa

(D)

dksbZ ugha

Use of air pre-heater is more suitable ............


(A) In general steam plant

337

P. T. O.

337

( 10 )

(B) In large steam power plant

(C) In small steam power plant

(D) None of these

16.

gok iwoZ rkid ls ckW;yj dh n{krk ij izHkko iM+rk gS ------(A)

vuqdwy

(B)

izfrdwy

(C)

fLFkj jgrk gS

(D)

dksbZ ugha

The boiler efficiency is effected by the air pre-heater ........

17.

(A) Suitable

(B) Adverse

(C) Remaining constant

(D) None of these

QhM okWVj ghVj ds iz;ksx ls ckW;yj Hkki cukrk gS


(A)

tYnh

(B)

de

(C)

nsjh ls

(D)

dksbZ ugha

By the use of feed water heater the boiler produces steam


(A) Soon

337

(B) Less

337

( 11 )

(C) Late

18.

(D) None of these

QhM okWVj ghVj ckW;yj dh c<+krk gS -----------(A) (Efficiency) n{krk

(B)

{kerk

(C)

(D)

dksbZ ugha

ngu nj

Feed water heater increases boiler's .............

19.

(A) Efficiency

(B) Capacity

(C) Combustion rate

(D) None of these

QhM okVj ghVj dk D;k dke gksrk gS


(A)

ty dks ok"i esa cnyuk

(B)

ty dks B.Mk djuk

(C)

QhM okVj dks xeZ djuk

(D)

dksbZ ugha

What is the function of feed water heater


(A) To convert water into steam
(B) To cool water
(C) To heat feed water

337

P. T. O.

337

( 12 )

(D) None of these

20.

iEi dk lD'ku izS'kj ok;qe.Myh; izS'kj ls gksrk gS


(A)

de

(B)

T;knk

(C)

cjkcj

(D)

dksbZ ugha

Suction pressure of feed pump is ............. than atmospheric


pressure

21.

(A) Less

(B) More

(C) Equal

(D) None of these

cUn QhM okWVj ghVj esa ikuh dk ljD;wys'ku gksrk gS


(A)

V~;wcksa ds ckgj ls

(B)

V~;wcksa ds vUnj ls

(C)

Me esa

(D)

dksbZ ugha

Water circulation in the closed type feed water heater is .....


(A) Out side the tubes

337

(B) In side the tubes

337

( 13 )

(C) In the drum

22.

(D) None of these

cUn QhM okWVj ghVj esa V~;wcksa ds ckgj D;k nkSjk djrh gS
(A)

Hkki

(B)

ikuh

(C)

nX/k xSlsa

(D)

dksbZ ugha

What circulates out side the tubes in the closed type feed
water heater

23.

(A) Steam

(B) Water

(C) Combustible gases

(D) None of these

cUn QhM okWVj ghVj esa rktk Hkki dk iz;ksx D;ksa ugha fd;k tkrk gS
(A)

b/ku dks cpkus ds fy;s

(B)

Hkki dks cpkus ds fy;s

(C)

ikuh dks cpkus ds fy;s

(D)

dksbZ ugha

Why does the fresh steam not use in the feed water heater
(A) To save the fuel

337

(B) To save steam

P. T. O.

337

( 14 )

(C) To save water

24.

(D) None of these

Dykst QhM okWVj ghVj dks dgk yxk;k tkrk gS


(A)

iEi ds vkmVySV ij

(B)

iEi ds buysV ij

(C)

iEi ds lekukarj ij

(D)

dksbZ ugha

Where is the closed feed water heater installed


(A) On out let of feed pump (B) On Inlet of feed pump
(C) Parallel to feed pump

25.

(D) None of these

DykslM QhM okVj ghVj dk izS'kj gksrk gS ---------(A)

ckW;yj izS'kj ls T;knk

(B)

ckW;yj izS'kj ls de

(C)

ckW;yj izS'kj ds cjkcj

(D)

dksbZ ugha

Pressure of closed type feed water heater is .................


(A) More than Boiler pressure
(B) Less than Boiler pressure

337

337

( 15 )

(C) Equal to Boiler pressure


(D) None of these

26.

fM&,bZjsVj ds iz;ksx ls vkWDlhtu dh ek=k jg tkrh gS


(A) 0.005 lh0
(C) 0.5 lh0

lh0/yhVj

lh0/yhVj

(B) 0.05 lh0


(D)

lh0/yhVj

dksbZ ugha

By the use De-aerator the amount of oxygen left

27.

(A) 0.005 C. C./Litre

(B) 0.05 C. C./Litre

(C) 0.5 C. C./Litre

(D) None of these

ckW;yj vkSj lqij ghVj dk izS'kj jgrk gS ------------(A)

de

(B)

cjkcj

(C)

T;knk

(D)

lHkh

The pressure of Boiler and super heater is ................

28.
337

(A) Less

(B) Equal

(C) More

(D) All of these

vf/kd rkieku gksus ls lqij ghVj dh V~;wc gks tkrh gS ----------P. T. O.

337

( 16 )

(A)

'kfDr'kkyh

(B)

detksj

(C)

izHkko'kkyh

(D)

dksbZ ugha

Due to high temperature the super heater tubes


becomes ............

29.

(A) Powerful

(B) Weak

(C) Effective

(D) None of these

lqijghVsM Hkki ds rkieku dks dUVksy djus okys ;U= dk uke gS -----(A)

,;j izh&ghVj

(B)

Mh&,bZjsVj

(C)

Mh&lqij ghVj

(D)

buesa ls dksbZ ugha

Name of the instrument which control temperature of


superheated steam is ..............

30.

337

(A) Air pre-heater

(B) De-aerator

(C) De-super heater

(D) None of these

lqijghVj esa LVhe dk rkieku c<+us ls LVhe dh okWY;we (volume) ---(A)

de gksrh gS

(B)

c<+rh gS

(C)

cjkcj jgrh gS

(D)

dksbZ ugha

337

( 17 )

By increase of temperature in the super heater the volume


of steam becomes ................
(A) Decrease

(B) Increases

(C) Equal

(D) None of these

337

P. T. O.

Vous aimerez peut-être aussi