0 évaluation0% ont trouvé ce document utile (0 vote)
19 vues3 pages
BioIDENTICA(r) Access Control is an application software for PC based biometric Access Control systems. It works together with fingerprint sensor devices of different manufacturers without any compatibility problems. The scanner has a resolution of 500 dpi and can capture more than 1000 fingerprints.
BioIDENTICA(r) Access Control is an application software for PC based biometric Access Control systems. It works together with fingerprint sensor devices of different manufacturers without any compatibility problems. The scanner has a resolution of 500 dpi and can capture more than 1000 fingerprints.
BioIDENTICA(r) Access Control is an application software for PC based biometric Access Control systems. It works together with fingerprint sensor devices of different manufacturers without any compatibility problems. The scanner has a resolution of 500 dpi and can capture more than 1000 fingerprints.
Bucharest, Romania Tel/Fax: +40-21-210.0363 Mail: info@trustnet.ro BioIDENTICA Access Control is an application software for PC based biometric access control systems. It works together with fingerprint sensor devices of different manufacturers without any compatibility problems. BioIDENTICA Access Control allows a highly performing identification with more than 1000 stored fingerprints. BioIDENTICA Access Control is ready for networking and obtains its biometric reference data sets from BioIDENTICARegistry. Depending on the fingerprint scanner BioIDENTICA Access Control meets low and medium security requirements. High security requirements are achieved in combination with further authentication means. The main product features Suitable for fingerprint identification of 1:1000 and more Continuous sensor monitoring, no button push necessary Locally mirrored reference data archive for maximum operational availability Adjustable automatic reference data archive update Extensive logging functions including image storage Compatible use of different fingerprint scanners Creation of supplementary reference images in bitmap (BMP) format Reference data exchange with BioIDENTICARegistry via LAN Sensor Properties High performance optical technology Active area: 30 x 30 mm Image size: 600 x 600 pixels Pixel raster: ~ 50 m Image resolution: 500 dpi Amplitude resolution: 8 bit, 256 gray values Designed to meet the resolution requirements of the Image Quality Specification (IQS) of the FBI's Electronic Fingerprint Transmission Specification (EFTS) Operating Conditions Indoor use Processor requirements: Pentium IV 2 GHz, 256 MB Operating system: MS Win 2000 SP3, XP SP1 Operating voltage: 5 V, powered by USB interface Operating current: max. 500 mA Ambient temperature: 10...40 C Relative humidity: 10 ...80% non condensing No direct sunlight exposure Hardware General Properties Highest quality optical fingerprint scanner for single flat fingers USB device version 2.0 with connector type B Cable clamped at the scanner side and protected against access Dimensions: 81 x 86 x 165 mm Scanner weight: 520 g MTBF: 40 000 h MCBF: 100 000 capturings MTTR: 2 weeks under normal operating conditions Rugged design, integrated Quick Snap'n Work holder BioIDENTICA Functionality Identification BioIDENTICA Access Control continuously reads out the fingerprint scanner. As soon as a usable fingerprint is detected, the identification process starts. In the case of a positive result, BioIDENTICA Access Control outputs corresponding control signals via the serial port which are suitable for the activation of an electrical door opener and signaling lamps. Simultaneously, the scanner output image and the identification result is displayed on the PC monitor. BioIDENTICA Access Control possesses a latent print recognition and rejection. Door control BioIDENTICA Access Control outputs the following states via a serial port: Green: access granted (10s) Yellow: stand-by Red: authentication failed - repeat trial after 10 seconds With the aid of an optional relay card three appropriate lamps and a door opener magnet can be driven. Logging functions BioIDENTICA Access Control stores the following data in a logging file: Identification date and time Identification result (successful, fail) Comparison result (maximum score value) ID number for the maximum score value Furthermore, BioIDENTICA Access Control offers the possibility to store the finger images of each transaction. Archive update BioIDENTICA Access Control is equipped with an automatic update which regularly synchronizes the local archive with the centrally stored reference data archive by LAN. Additionally, the update can be forced from the identification PC manually every time. Settings In the menu "Options" the directories for the local reference data archive, the central reference data archive, and the logging data can be chosen. Further settings are provided for the serial port and the daily time for reference data update. 15 Viesparilor street, flat 2 Bucharest, Romania Tel/Fax: +40-21-210.0363 Mail: info@trustnet.ro BioIDENTICA Screenshots Enrollment Identification display and settings 15 Viesparilor street, flat 2 Bucharest, Romania Tel/Fax: +40-21-210.0363 Mail: info@trustnet.ro