Vous êtes sur la page 1sur 2

1

Glass-Fiber ,Performed
Pipe insulation Type 1 454
C
38 48-96 ASJ-SSL FOSTER 32-17 FOSTER 85-20 FOSTER 30-90
ASJ ( Venture Tape ) 1540CW Plus,1542CWPlus
2
Glass-Fiber ,Performed
Pipe insulation Type 1 454
C
50 48-96 ASJ-SSL FOSTER 32-17 FOSTER 85-20 FOSTER 30-90
ASJ ( Venture Tape ) 1540CW Plus,1542CWPlus
3
Glass-Fiber ,Performed
Pipe insulation Type 1 454
C
75 48-96 ASJ-SSL FOSTER 32-17 FOSTER 85-20 FOSTER 30-90
ASJ ( Venture Tape ) 1540CW Plus,1542CWPlus
DENSITY
kg/cu.m
THIKNES (
mm)
INSULATION TYPE ADHESIVE MASTIC TAPE
FIELD-APPLIED FABRIC-REINFORCING MESH FILED APPLIED JACKET
INDOOR CHILLED WATER PIPING INSULATION SCHEDULE
FACTORY
APPLIED
JACKET
SN SEALANT
1- Piping Concealed : Woven Glass-Fiber Fabric Materia
1- Piping Concealed : Woven Glass-Fiber Fabric Material.
2- Piping Exposed : AluminumCladding, Smooth: 0.032 inch (0.81 mm) thick finish. AluminumJacket: Comply with ASTMB 209
(ASTMB 209M), Alloy 3003, 3005,3105 or 5005, Temper H-14. Moisture Barrier 3-mil- (0.075-mm-) thick, heatbonded polyethylene
and kraft paper AluminumJacket in car park shall be painted prior to procurement at site with baked on factory paint with color as
approved by the site Engineer.
FIELD-APPLIED FABRIC-REINFORCING MESH FILED APPLIED JACKET
2- Piping Exposed - Woven Glass-Fiber Fabric for Duct and Equipment Insulation: Approximately 8
oz./sq. yd. (271 g/sq. m) with a thread count of 5 strands by 5 strands/sq. inch (2 strands by 2
strands/sq. mm) for covering equipment.
2- Piping Exposed : AluminumCladding, Smooth: 0.032 inch (0.81 mm) thick finish. AluminumJacket: Comply with ASTMB 209
(ASTMB 209M), Alloy 3003, 3005,3105 or 5005, Temper H-14. Moisture Barrier 3-mil- (0.075-mm-) thick, heatbonded polyethylene
and kraft paper AluminumJacket in car park shall be painted prior to procurement at site with baked on factory paint with color as
approved by the site Engineer
CHILLED WATER PIPE SIZE DN 63 mm to DN 300 mm
All Pipe Sizes Refrigerant and Hot-Gas Piping
LOCATION/ AREA
B2,B1,G.F,M1,M2,
SS1..,SS6
B1,G.F
B2,B1,G.F,M1,M2,
1- Piping Concealed - Woven Glass-Fiber Fabric for Pipe Insulation: Approximately 8 oz./sq. yd.
(271 g/sq. m) with a thread count of 10 strands by 10 strands/sq. inch (4 strands by 4 strands/sq.
mm) for covering pipe and pipe fittings.
2- Piping Exposed - Woven Glass-Fiber Fabric for Duct and Equipment Insulation: Approximately 8
oz./sq. yd. (271 g/sq. m) with a thread count of 5 strands by 5 strands/sq. inch (2 strands by 2
strands/sq. mm) for covering equipment.
1- Piping Concealed - Woven Glass-Fiber Fabric for Pipe Insulation: Approximately 8 oz./sq. yd.
(271 g/sq. m) with a thread count of 10 strands by 10 strands/sq. inch (4 strands by 4 strands/sq.
mm) for covering pipe and pipe fittings.
2- Piping Exposed - Woven Glass-Fiber Fabric for Duct and Equipment Insulation: Approximately 8
oz./sq. yd. (271 g/sq. m) with a thread count of 5 strands by 5 strands/sq. inch (2 strands by 2
strands/sq. mm) for covering equipment.
CHILLED WATER PIPE SIZE DN 50mm and Smaller
CHILLED WATER PIPE SIZE DN 350 mmand Larger
FIELD-APPLIED FABRIC-REINFORCING MESH FILED APPLIED JACKET
1- Piping Concealed - Woven Glass-Fiber Fabric for Pipe Insulation: Approximately 8 oz./sq. yd.
(271 g/sq. m) with a thread count of 10 strands by 10 strands/sq. inch (4 strands by 4 strands/sq.
mm) for covering pipe and pipe fittings.
2- Piping Exposed - Woven Glass-Fiber Fabric for Duct and Equipment Insulation: Approximately 8
oz./sq. yd. (271 g/sq. m) with a thread count of 5 strands by 5 strands/sq. inch (2 strands by 2
strands/sq. mm) for covering equipment.
1- Piping Concealed : Woven Glass-Fiber Fabric Material.
2- Piping Exposed : AluminumCladding, Smooth: 0.032 inch (0.81 mm) thick finish. AluminumJacket: Comply with ASTMB 209
(ASTMB 209M), Alloy 3003, 3005,3105 or 5005, Temper H-14. Moisture Barrier 3-mil- (0.075-mm-) thick, heatbonded polyethylene
and kraft paper AluminumJacket in car park shall be painted prior to procurement at site with baked on factory paint with color as
approved by the site Engineer
DENSITY
kg/cu.m
THIKNES (
mm)
INSULATION TYPE ADHESIVE MASTIC TAPE
INDOOR CHILLED WATER PIPING INSULATION SCHEDULE
FACTORY
APPLIED
JACKET
SN SEALANT LOCATION/ AREA
CHILLED WATER PIPE SIZE DN 50mm and Smaller
4 Polyolefin 38 40 FOSTER 32-17 FOSTER 85-20 FOSTER 30-90 ASJ ( Venture Tape ) 1540CW Plus,1542CWPlus
5 Phenolic 25 32 ASJ FOSTER 32-17 FOSTER 85-20 FOSTER 30-90
ASJ ( Venture Tape ) 1540CW Plus,1542CWPlus
FIELD-APPLIED FABRIC-REINFORCING MESH FILED APPLIED JACKET
FIELD-APPLIED FABRIC-REINFORCING MESH FILED APPLIED JACKET
1- Piping Concealed : Woven Glass-Fiber Fabric Materia
2- Piping Exposed : AluminumCladding, Smooth: 0.032 inch (0.81 mm) thick finish. AluminumJacket: Comply with ASTMB 209
(ASTMB 209M), Alloy 3003, 3005,3105 or 5005, Temper H-14. Moisture Barrier 3-mil- (0.075-mm-) thick, heatbonded polyethylene
and kraft paper AluminumJacket in car park shall be painted prior to procurement at site with baked on factory paint with color as
approved by the site Engineer
B2,B1,G.F,M2, Roof
Cooling Tower& Cooling
Planet
1- Piping Concealed - Woven Glass-Fiber Fabric for Pipe Insulation: Approximately 8 oz./sq. yd.
(271 g/sq. m) with a thread count of 10 strands by 10 strands/sq. inch (4 strands by 4 strands/sq.
mm) for covering pipe and pipe fittings.
2- Piping Exposed - Woven Glass-Fiber Fabric for Duct and Equipment Insulation: Approximately 8
oz./sq. yd. (271 g/sq. m) with a thread count of 5 strands by 5 strands/sq. inch (2 strands by 2
strands/sq. mm) for covering equipment.
Condenser Water Piping