Integrated Suite of 12 Instruments for Hands-On,

Multidiscipline Education
Overview
The NI Educational Laboratory Virtual Instrumentation Suite (NI ELVIS)
is a hands-on design and prototyping platform that integrates 12 of the
most commonly used instruments including the oscilloscope, DMM,
function generator, and Bode analyzer into a compact form factor ideal
for the hardware lab or classroom. A 100 MS/s oscilloscope option is
available on the NI ELVIS II+.
Based on NI LabVIEW graphical system design software, NI ELVIS,
with USB plug-and-play capabilities, offers the flexibility of virtual
instrumentation and allows for quick and easy measurement acquisition
and display.
This hardware platform, used from first-year classes to advanced
senior classes, helps educators teach a variety of concepts, including
measurement and instrumentation, analog and digital circuits, controls
and mechatronics, telecommunications, and embedded theory.
Design and prototyping platform for
measurement and instrumentation,
circuits, controls, telecommunications,
and embedded/MCU experiments
Complete integration with Multisim for
circuits and electronics
Completely open and customizable
in LabVIEW
Express VIs for point-and-click
configuration in LabVIEW and
LabVIEW SignalExpress
Platform Features
Open architecture for third-party
plug-in boards
Hi-Speed USB plug-and-play connectivity
1.25 MS/s oscilloscope with 100 MS/s
option on NI ELVIS II+
5
1
2-digit isolated digital multimeter
15 and +5 V power supply
Manual control function generator and
variable power supply
Circuit protection with resettable fuse
Integrated Suite
of 12 Virtual Instruments
Oscilloscope
Function generator (manual control)
Digital multimeter (DMM)
Arbitrary waveform generator
Bode analyzer
2-wire current voltage analyzer
3-wire current voltage analyzer
Dynamic signal analyzer (DSA)
Impedance analyzer
Digital reader
Digital writer
Variable power supply (manual control)
Recommended Software
LabVIEW
NI Circuit Design Suite
Driver Software (included)
NI-ELVISmx
LabVIEW SignalExpress
NI ELVIS II/II+ NEW!
Features NI ELVIS I NI ELVIS II NI ELVIS II+
12 integrated instruments
PCI/PCMCIA
Integrated USB
Isolated digital multimeter
NI-DAQmx software
True Multisim integration
100 MS/s oscilloscope
Table 1. NI ELVIS Platform Comparison
Figure 1. The NI ELVIS Education Platform
Textbooks Multisim
Design Theory
NI ELVIS Education Platform
Circuit Design and
Instrumentation
Telecommunications
Controls and
Mechatronics
Embedded
NI ELVIS LabVIEW
Deploy Prototype
NI Electronics Education Platform
NI ELVIS, an integral part of the NI electronics education platform,
combines simulation and measurements from NI ELVIS inside the
NI Multisim capture and SPICE simulation environment. Students
transfer concepts taught in a textbook to Multisim, where they can
learn through modeling circuit behavior and interactive circuits. They
can compare simulation and real measurements with a single mouse
click using NI ELVIS instruments inside the Multisim environment and
achieve more complex analysis using LabVIEW or LabVIEW
SignalExpress.
For more information on the NI electronics education platform,
visit ni.com/academic/eep.
NI-ELVISmx Driver and LabVIEW Accessibility
With the NI-ELVISmx driver, students can access their suite of
12 instruments through the NI-ELVISmx instrument launcher. These
virtual instruments with their soft front panels provide an interactive
interface to configure instruments.
NI ELVIS virtual instruments are open-sourced and customizable in
LabVIEW. With the installation of the driver, students can use LabVIEW
Express VIs and LabVIEW SignalExpress steps to program their devices.
This provides point-and-click configuration capabilities for the individual
instruments, so they can achieve customized and more complex analysis
of acquired data in LabVIEW.
Those who are familiar with the DAQmx API can program general
analog input, analog output, and timing functionality on NI ELVIS
using NI-DAQmx.
Teach a Variety of Disciplines with Plug-In Boards
Educaters can extend their labs beyond instrumentation and circuits
with NI ELVIS plug-in boards and courseware from third-party
collaborators such as Emona, Freescale Semiconductor, and Quanser
to teach telecommunications, microcontroller, and control concepts.
National Instruments also now provides introduces a digital
electronics and field-programmable gate array (FPGA) plug-in board
for the platform.
NI ELVIS is an open architecture, which helps leading teaching
solution providers take advantage of the platform. The following plug-in
boards are available from the following companies.
Digital Electronics with National Instruments
NI Digital Electronics FPGA Board based on Xilinx Spartan-3E FPGA
Control and Simulation with Quanser
QNET-010 DC motor control
QNET-011 rotary inverted pendulum
QNET-012 HVAC system
QNET-013 Vertical Take-Off and Landing (VTOL) actuator
QNET-014 mechatronics sensor 1
Integrated Suite of 12 Instruments for Hands-On, Multidiscipline Education
2
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Figure 2. Integration with NI LabVIEW
Figure 3. NI Digital Electronics FPGA Board and NI ELVIS II+
Figure 4. Quanser QNET Plants and NI ELVIS II
Embedded/MCU Design with Freescale
Embedded/MCU design with Freescale Microcontroller Student
Learning Kit (SLK)
Telecommunications and Fiber Optics with Emona
Telecommunications with Emona DATEx
Fiber optics with Emona FOTEx
Other Companion Products
Circuits NI electronics education platform with Multisim
Embedded/DSP Analog Devices ADSP-BF537 Blackfin Processor
Sensors Vernier sensor adapters for NI ELVIS
Integrated Suite of 12 Instruments for Hands-On, Multidiscipline Education
3
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Figure 5. Freescale Microcontroller SLK and NI ELVIS II
Figure 6. Emona FOTEx Fiber Optics Board and NI ELVIS II+
Ordering Information
Bundles
NI ELVIS II+ Circuit Design Bundle........................................780379-02
NI ELVIS II Circuit Design Bundle..........................................780379-01
Includes NI ELVIS workstation, Multisim, LabVIEW, LabVIEW SignalExpress, and user manual.
NI ELVIS II+ Basic Bundle......................................................780378-02
NI ELVIS II Basic Bundle........................................................780378-01
Includes NI ELVIS workstation, LabVIEW, LabVIEW SignalExpress, and user manual.
NI ELVIS II+ instrumentation design
and training platform ............................................................780380-02
NI ELVIS II instrumentation design
and training platform ............................................................780380-01
Includes NI ELVIS workstation only and user manual for industry and vocational training.
NI ELVIS II prototyping board ................................................188432-01
Used with NI ELVIS II and NI ELVIS II+.
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/nielvis.
Specifications
>>
For complete specifications, see the NI ELVIS II series user manual
at ni.com/manuals.
Performance is typical at 25 C unless otherwise specified.
Analog Input
Channels.............................................. 8 differential or 16 single-ended
ADC resolution.................................... 16 bits
Absolute accuracy............................... Refer to NI ELVIS II
Maximum sampling rate..................... 1.25 MS/s single channel,
1.00 MS/s multichannel
(aggregate)
Input range.......................................... 10, 5, 2, 1, 0.5, 0.2,
and 0.1 V
Maximum working voltage for analog inputs
(signal + common mode) ................ 11 V of AIGND
Input impedance
Device on AI+ or AI- to AIGND........ >10 G || 100 pF
Device off AI+ or AI- to AIGND....... 820
Small signal bandwidth (-3 dB) .......... 1.2 MHz
Analog Triggers
Number of triggers.............................. 1
Source ................................................. AI<0..15>, and available on
NI ELVIS II only, ScopeCH0,
ScopeCH1
Functions ............................................. Start trigger, reference trigger,
pause trigger, sample clock,
convert clock, sample
clock timebase
Source level ........................................ Full scale
Resolution ........................................... 10 bits
Modes ................................................. Analog edge triggering, analog
edge triggering with hysteresis,
and analog window triggering
Arbitrary Waveform Generator/Analog Output
Channels.............................................. 2
DAC resolution.................................... 16 bits
Maximum update rate
1 channel ........................................ 2.8 MS/s
2 channels....................................... 2.0 MS/s
Timing resolution ................................ 50 ns
Output range ....................................... 10 V, 5 V
Slew rate............................................. 20 V/s
Digital I/O and PFI
Channels.............................................. 24 DIO,15 PFI
Direction control ................................. Each line individually
programmable as input or output
Pull-down resistor ............................... 50 k typ, 20 k min
General-Purpose Counter/Timers
Counter/timers.................................... 2
Resolution ........................................... 32 bits
Counter measurements....................... Edge counting, pulse, semiperiod,
period, two-edge separation
Position measurements ...................... X1, X2, X4 quadrature encoding
with Channel Z reloading;
two-pulse encoding
Output applications............................. Pulse, pulse train with dynamic
updates, frequency division,
equivalent time sampling
External base clock frequency............ 0 to 20 MHz
Base clock accuracy............................ 50 ppm
Maximum frequency ........................... 1 MHz
Inputs................................................... Gate, source, HW_Arm, Aux,
A, B, Z, Up_Down
Frequency Generator
Channels.............................................. 1
Base clocks ......................................... 10 MHz, 100 kHz
Divisors................................................ 1 to 16
Maximum frequency ........................... 1 MHz
Base clock accuracy............................ 50 ppm
External Digital Triggers
Source ................................................. TRIG BNC or any PFI
Polarity ................................................ Software-selectable for
most signals
Analog input function ......................... Start trigger, reference
trigger, pause trigger, sample
clock, convert clock, sample
clock timebase
Analog output function....................... Start trigger, pause trigger, sample
clock, sample clock timebase
Counter/timer function ....................... Gate, source, HW_Arm, Aux,
A, B, Z, Up_Down
Digital Multimeter (DMM)
Isolated functions ............................... DC voltage, AC voltage, DC current,
AC current, resistance, diode
Isolation level...................................... 60 VDC/20 V
rms
,
Installation Category I
Resolution ........................................... 5 digits
Input impedance ................................. 11 M
Nonisolated functions......................... Capacitance, inductance
Voltage Measurement
DC ranges............................................ 100 mV, 1 V, 10 V, 60 V
AC ranges............................................ 200 mV
rms
, 2 V
rms
, 20 V
rms
Accuracy.............................................. Refer to NI ELVIS II
Current Measurement
DC range ............................................. 2 A
AC ranges............................................ 500 mA
rms
, 2 A
rms
Shunt resistor...................................... 0.1
Burden voltage.................................... <0.6 V
Accuracy.............................................. Refer to NI ELVIS II
Input protection................................... F 3.15 A 250 V, fast-acting
user-replaceable fuse
Integrated Suite of 12 Instruments for Hands-On, Multidiscipline Education
4
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Resistance Measurement
Ranges................................................. 100 , 1 k, 10 k, 100 k,
1 M, 100 M
Accuracy.............................................. Refer to NI ELVIS II
Diode Measurement
Range .................................................. 10 V
Nominal test current........................... 100 A (10 V range)
Capacitance Measurement
Range .................................................. 50 pF to 500 F
Accuracy.............................................. 1%
Inductance Measurement
Range .................................................. 100 H to 100 mH
Accuracy.............................................. 1%
Function Generator
Channels.............................................. 1
Output waveform type........................ Sine, square, triangle
Frequency range.................................. 0.186 Hz to 5 MHz (sine)
0.186 Hz to 1 MHz
(square and triangle)
Frequency resolution........................... 0.186 Hz
Waveform amplitude range................ 10 V
pp
Waveform amplitude resolution......... 10 bits
Waveform amplitude accuracy........... 1% 15 mV
Waveform offset range....................... 5 V
Duty cycle range ................................. 0 to 100%
Output impedance............................... 50
Maximum output current .................... 100 mA
Modulation
Inputs................................................... 2 (AM and FM)
Modulation input range...................... 10 V
Amplitude modulation factor.............. 10%/V
Frequency modulation factor .............. 20%/V
Oscilloscope (NI ELVIS II)
Channels.............................................. 2
Input coupling ..................................... AC or DC
Input impedance ................................. 1 M || 25 pF
Bandwidth (-3 dB) ............................... 1.7 MHz
AC coupling cutoff frequency (-3 dB).. 10 MHz
Resolution ........................................... 16 bits
Maximum sampling rate..................... 1.25 MS/s (single channel)
500 kS/s (two channels)
DC accuracy ........................................ Refer to NI ELVIS II
Oscilloscope (NI ELVIS II+)
Channels.............................................. 2
Input coupling ..................................... AC, DC, GND
Input impedance ................................. 1 M || 21 pF
Bandwidth (-3 dB) ............................... 35 MHz (40 mV
pp
range)
50 MHz (all other ranges)
Optional noise filter ............................ 20 MHz
AC coupling cutoff frequency (-3 dB) ... 12 Hz
Resolution ........................................... 8 bits
Maximum sampling rate..................... 100 MS/s (two channels)
Timebase accuracy.............................. 50 ppm
Waveform memory.............................. 16384 samples per channel
DC accuracy ........................................ Refer to NI ELVIS II/II+
Dynamic Signal Analyzer
Frequency resolution........................... Software-controllable
(200, 400, 800, 1600, 3200 lines)
Accuracy.............................................. Refer to NI ELVIS II
Bode Analyzer
Frequency range.................................. 1 Hz to 200 kHz (ELVIS II);
1 Hz to 5 MHz (ELVIS II+)
Accuracy.............................................. Refer to NI ELVIS II
Two-Wire Current-Voltage Analyzer
Current range ...................................... 40 mA
Voltage sweep range.......................... 10 V
Three-Wire Current-Voltage Analyzer
Supported devices .............................. NPN and PNP transistors
Minimum base current increment ...... 0.48 A
Maximum collector current................. 40 mA
Maximum collector voltage................ 10 V
Impedance Analyzer
Measurement frequency range .......... 1 Hz to 35 kHz
Power Supplies
+15 V Supply
Output voltage (no load) ..................... +15 V 5%
Maximum output current .................... 500 mA
Short circuit protection....................... Resettable circuit breaker
-15 V Supply
Output voltage (no load) ..................... -15 V 5%
Maximum output current .................... 500 mA
Short circuit protection....................... Resettable circuit breaker
+5 V Supply
Output voltage (no load) ..................... +5 V 5%
Maximum output current .................... 2 A
Short circuit protection....................... Resettable circuit breaker
Positive Variable Supply
Output voltage .................................... 0 to +12 V
Voltage setpoint resolution ................ 10 bits
Voltage accuracy (no load).................. 100 mV
Maximum output current .................... 500 mA
Short circuit protection....................... Self-resetting current limiter
Negative Variable Supply
Output voltage .................................... 0 to -12 V
Voltage setpoint resolution ................ 10 bits
Voltage accuracy (no load).................. 100 mV
Maximum output current .................... 500 mA
Short circuit protection....................... Self-resetting current limiter
Integrated Suite of 12 Instruments for Hands-On, Multidiscipline Education
5
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Calibration
Recommended warm-up time............. 15 minutes
Calibration interval ............................. 1 year
Communication
Bus interface....................................... Hi-Speed USB
Physical
Dimensions.......................................... 34.3 by 28.0 by 7.6 cm
(14.5 by 11 by 3 in.)
Weight (with prototyping board) ........ 1.9 kg (4.2 lb)
Environmental
Operating temperature ....................... 10 to 35 C
Storage temperature........................... 65 C
Humidity .............................................. 10 to 90% relative
humidity, noncondensing
Maximum altitude............................... 2000 m
Pollution degree (indoor use only) ...... 2
Integrated Suite of 12 Instruments for Hands-On, Multidiscipline Education
6
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications and
systems engineers and a worldwide National Instruments Alliance Partner
program of more than 600 independent consultants and integrators. Services
range from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within
NI Developer Exchange forums. Find immediate answers to your questions
at ni.com/support.
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Visit ni.com/ssp.
Hardware Services
System Assurance Programs
NI system assurance programs are designed to make it even easier for you to
own an NI system. These programs include configuration and deployment
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The
NI Basic System Assurance Program provides a simple integration test and
ensures that your system is delivered completely assembled in one box.
When you configure your system with the NI Standard System Assurance
Program, you can select fromavailable NI systemdriver sets and application
development environments to create customized, reorderable software
configurations. Your systemarrives fully assembled and tested in one box with
your software preinstalled. When you order your system with the standard
program, you also receive system-specific documentation including a bill of
materials, an integration test report, a recommended maintenance plan, and
frequently asked question documents. Finally, the standard program reduces
the total cost of owning an NI system by providing three years of warranty
coverage and calibration service. Use the online product advisors at
ni.com/advisor to find a system assurance program to meet your needs.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-
accuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE
NEEDS
M
A
I
N
T
A
IN
P
L
A
N
D
E
V
E
L
O
P
D
E
P
L
O
Y
2009 National Instruments. All rights reserved. CompactRIO, FieldPoint, LabVIEW, Multisim, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SignalExpress are trademarks
of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent
from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-10911-301-101-D
National Instruments info@ni.com
ni.com 800 813 3693

NI-ELVIS Series II
The major device that you will use in this lab is the NI ELVIS Series II workstation shown in Figure 1. The workstation consists
of a prototyping board and several other features that are essential for laboratory experiments conducted in the ECE department.
These features are explained below in Table 1:


Figure 1. Isometric View of NI ELVIS II workstation with Prototyping Board
TABLE I. WORKSTATION FEATURES

Workstation Power
Switch
Located in the rear of the workstation
Powers the NI ELVIS II series


Prototyping Board
Power Switch
Controls power to NI ELVIS Series II prototyping board.
The power LED lights up when the switch is turned ON.
The Ready switch should be green or yellow when
connected to host.


Digital Multimeter
(DMM) Connectors

Voltage, Resistance, and Diode Banana Jack (red):
The positive input for digital multimeter in voltage
resistance and diode measurements.
Common Banana Jack (black): The common reference
connection for digital multimeter voltage, current,
resistance, and diode measurements.
Current Banana Jack (red): The positive input for
digital multimeter current measurements.



Oscilloscope
Connectors and
Function Generator
Outputs/Digital
Trigger Input

Oscilloscope (Scope) Connectors (Input)
CH 0 BNC Connector: The input for channel 0 of the
oscilloscope.
CH 1 BNC Connector: The input for channel 1 of the
oscilloscope.

FGEN/Trigger Connector
Optional output of the function generator or a digital
trigger input.


Variable Power
Supply Manual
Controls
This allows you to adjust the voltage for two variable
power supplies.
Supply+ which can supply between 0 and +12V
Supply can which supply between 0 and -12V
Knobs active only when the associated power supply is
in manual mode.
LED lights up next to each knob lights up when
associated power supply is in manual mode.


Function Generator
Manual Control
These knobs allow the user to manually adjust the
frequency and amplitude for a function generator output
waveform. The Manual Mode LED lights up when the
function generator is in manual mode.
Instructions on how to use the function generator to input a
waveform and to adjust its frequency and amplitude are
explained later.


NI ELVIS II Series
Prototyping Board
Provides an area for building circuitry and has necessary
connections to access signals for common applications










I. PROTOTYPING BOARD FEATURES
The prototyping board has several features on interest that are labeled in Figure 2. Each signal in features 2, 3, 6 and 8 has a row
of five pin sockets all tied together.

Figure 2. NI ELVIS II Series Prototyping Board
TABLE II. SIGNAL DESCRIPTIONS ON NI ELVIS II PROTOTYPING BOARD.

Breadboard
This is the work area on which most circuits are built.
Figure 3 shows how the terminals are internally
connected.
The horizontal connections labeled + and - and
colored red and blue are called buses and are typically
used for power and ground signals.
The vertical contacts are used for the actual building of
circuits


Analog Input (AI) and
Programmable Functions
Interface (PFI) signal rows
Analog Inputs
There are 8 analog input channels labeled AI<07>.
Connect positive end of the signal to be measured to
the positive + pin socket and the negative end of the
signal to the negative - pin socket of the input
channel. These channels are mostly used as inputs for
the oscilloscope discussed later.
Programmable Functions I/O
These lines labeled <02>, <57> and <1011>
are used for static digital input output or timing
signals.
AI SENSE and AI GND (INPUT)
These pin sockets are used in cases where the signal to
be measured has a different ground potential from the
workstation.








Digital
Multimeter(DMM)/
Impedance Analyzer









DMM/Impedance Analyzer (INPUT)
BASE: excitation terminal used as base terminal in 3-
wire voltage/current analyzer of a bipolar junction
transistor discussed later.
DUT+: excitation for capacitance and inductance
measurements, impedance analyzer, 2-wire
voltage/current analyzer and collector terminal for a
bipolar junction transistor for 3-wire voltage/current
analyzer. All of which are discussed later.
DUT-: virtual ground for capacitance and inductance
measurements, impedance analyzer, 2-wire
voltage/current analyzer and emitter terminal for a
bipolar junction transistor for 3-wire voltage/current
analyzer.
Analog Output (AO)


Analog Outputs
There are 2 analog output channels labeled
AO<01>. These channels are used as outputs for
the arbitrary waveform generator discussed later.
User Configurable
Input/Output


User Configurable I/O
BANANA <AD>: Connects to the banana jacks A-
D (see feature 4).
BNC <12>: Positive lines connect to center pins of
the BNC connectors (see feature 4). Negative lines
connect to shells of the BNC connectors.
SCREW TERMINAL <12>: connects to the screw
terminals (see feature 4).
Function Generator
(FGEN)

Function Generator
FGEN (Output): the output of the function generator
SYNC (Output): 5V TTL signal synchronized to the
FGEN signal. This signal is most used as a trigger
signal for the oscilloscope (see feature 4 in Table 1).
AM (Input): Analog input used to modulate the
amplitude of the FGEN signal.
FM (Input): Analog input used to modulate the
frequency of FGEN signal.




Power Supplies


Variable Power Supplies (OUTPUT)
SUPPLY+: Positive variable power supply output (see
feature 5 in Table 1). Can supply between 0 and
+12V.
GROUND: Ground (all signals referenced to ground).
SUPPLY-: Negative variable power supply output
(see feature 5 in Table 1). Can supply between 0 and -
12V.

DC Power Supplies (OUTPUT)
+15V fixed power supply.

-15V fixed power supply.
GROUND: Ground.
+5V fixed power supply


User-Configurable Screw
Terminals, BNC
connectors and Banana
jack connectors
Banana <AD> Jacks: connected to BANANA
<AD> signal rows (see feature 3).
BNC <12> Connectors: connected to BNC
<12> signal rows (see feature 3).
SCREW TERMINAL <12>: connects to the
screw terminal signal rows (see feature 3).


DC power supply
indicators

15V and +5V power supply indicators: These
indicators should be lit to when the prototyping board
power is enabled.
If these indicators are not lit, then there is a possible
short circuit. Turn off prototyping board and check
connections.
Turning the board power switch on and off should reset
the current limiters.



Digital input/output signal
rows
DIO <023> (INPUT/OUTPUT)
Digital I/O lines that are used to read or write digital data
(0 or 5V). These lines are programmed to be inputs or
outputs using soft front panels (SFPs) discussed later.


User-Configurable LEDs
User-Configurable LEDs (OUTPUT)
These LEDs act as displays for digital outputs (i.e. 0 or
5V). See feature 8 for further insight.


Counter/Timer
User-Configurable
Input/Output
DC Power Supply
Counter/Timer (INPUT/OUTPUT)
PFI8/CTRO_SOURCE: Counter 0 Source
PFI9/CTRO_GATE: Counter 0 Gate
PFI12/CTRO_OUT: Counter 0 Out
PFI3/CTR1_SOURCE: Counter 1 Source
PFI4/CTR1_GATE: Counter 1 Gate
PFI13/CTR1_OUT: Counter 1 Out
PFI14/FREQ_OUT: Frequency Out
LED<07> (INPUT)
Input pin sockets for user-configurable LEDs (see
feature 7).
DSUB SHIELD (INPUT/OUTPUT)
Connects to shield of DSUB connector (see feature 9).
DSUB PIN<19> (INPUT/OUTPUT)
Connects to pins <19> of DSUB connector (see
feature 9).
DC Power Supply (OUTPUT)
Ground
+5V fixed power supply


User-Configurable DSUB
connector
DSUB Connector (I/O)
Connected to DSUB PIN <19> and DSUB SHIELD
signal rows (see feature 8).


Each of these five set of contacts are tied together
All pins on each of these columns are connected together.
So the user can use + for DC power supply and - for ground

Figure 3. Breadboard connections

II. NI ELVIS II DEVICES
This chapter provides an overview of the devices present in the NI ELVIS II Series workstation. These devices can be
controlled by software to include soft front panel (SFP) instruments, LabVIEW Express VIs, and SignalExpress blocks. For the
purposes of the ECE department, the use of NI ELVIS II Series with SFP instruments will be discussed exclusively. A NI
ELVISmx SFP, as the name implies, is the software version of the front panel of an NI ELVIS device.
A. NI ELVISmx Instrument Launcher:
The NI ELNIS Instrument Launcher provides access to the NI ELVISmx SFP instruments. Launch the Instrument Launcher by
navigating to Start>>All Program Files>>National Instruments>>NI ELVISmx>>NI ELVISmx Instrument Launcher. This
opens the GUI shown in Figure 4. To launch an instrument, click the button corresponding to the desired instrument. Before
opening a SFP, the workstation should be powered with the USB READY light lit, otherwise an error occurs. If said error occurs,
close SFP, power on the workstation, check connection to host PC, and open SFP again.


Figure 4. NI ELVISmx Instrument Launcher

B. DMM (Digital Multimeter)
This commonly used instrument is used to measure voltage (DC and AC), current (DC and AC), resistance, capacitance,
inductance. Additionally it used for diode tests and audible continuity tests. The DMM SFP is shown in Figure 5.
The top row of nine buttons denotes the different DMM modes, namely from left to right: DC voltage measurement, AC voltage
measurement, DC current measurement, AC current measurement, resistance measurement, capacitance measurement, inductance
measurement, diode continuity and audible continuity. An explanation of the labeled controls is as follows.
1. Display: This is when the current measurement is displayed. The %FS bar shows the percentage of the current range that
is being used. The higher the percentage, the more accurate the result (see 8 for more details).
2. Modes: These rows of buttons are used to the select the operation the user would like the digital multimeter to perform.
3. Connections: shows where to connect the signal or device to be measured.
4. Acquisition mode: This selection determines whether the user wants the digital multimeter to keep measuring indefinitely
(continuously) or just taking one measurement and stop.
5. Help: The button brings up the contest help and the online help for the soft front panel instrument.
6. Run/Stop: These buttons are used to start data acquisition (Run) and to stop data acquisition (Stop).
7. Null offset: This is an important control of the SFP. Say the user is taking small magnitude measurements and the null
value (value with nothing connected) is substantial enough to affect the data readings. By clicking the null offset button at
null, all subsequent measurements are made relative to the measurement when the button was pressed, which will
improve the accuracy of the measurements. It is not advisable to offset null for AC voltage measurements.
8. Mode: Selects between Auto and Manual ranging of the instrument. It is recommended to use the Auto ranging
(default). If Manual is selected, then the Range menu is enabled and different ranges can be selected.


Figure 5. DMM SFP with important controls labeled

1) DC and AC voltage measurements
These modes are selected when user requires measurements of time invariant (DC) voltage and time varying (AC) current
respectively. The measurements are made in terms of DC Voltage (VDC) and RMS Voltage (VAC) respectively. The signal
connections for both modes are the same. The positive end is connected to the red voltage, resistance, and diode banana jack shown
in feature 3 in Table 1. The negative end is connected to the black common banana jack (COM) also shown in feature 3 in Table 1.
2) DC and AC current measurements
These modes are selected when user requires measurements of time invariant current and time varying current respectively. The
measurements are made in terms of DC amperes (IDC) and Ampere RMS (IAC) respectively. The signal connections for both

modes are the same. The positive end is connected to the red current banana jack (A) shown in feature 3 in Table 1. The negative
end is connected to the black common banana jack (COM) also shown in feature 3 in Table 1.
3) Resistance Measurement
This mode is used when user requires the resistance of a device under test. The measurements are made in terms of ohms ().
The device connections are the same as that of the DC and AC voltage measurements.
4) Capacitance and Inducatnace Measurement
This mode is selected when user requires the capacitance and inductance of a device respectively. The measurements are made
in terms of Farads (F) and Henry (H) respectively. The positive end of the device under test should be connected to the pin DUT+
on the prototyping board, shown in feature 3 in Table 2. The negative end of the device under test should be connected to the pin
DUT- on the prototyping board, also shown in feature 3 in Table 2.

5) Diode
This mode is selected when the user wants to determine the terminals of a diode (i.e. whether the device is forward-biased or
reverse-biased). The multimeter indicates when the device under test is open or closed. The device connections are the same as that
of the DC and AC voltage measurement.
6) Continuity
This mode is selected when the user wishes to determine if two nodes (or pin sockets) are at the same potential (or tied
together). If said nodes are connected together, an audible cue is given and additionally the display shows Closed. Otherwise
there is no audible cue and the display shows Open.
C. Scope (Oscilloscope)
The oscilloscope is a device that displays signal voltages as a two-dimensional graph of electrical potential differences (vertical
axis) plotted as a function of time (horizontal axis). Though time-invariant (DC) voltages can be displayed, this device is commonly
used to display time-varying voltage signals. The NI ELVISmx Oscilloscope consists of two channels, Channel 0 and Channel 1,
which can automatically connect to up to ten (10) sources. Shown below is the Scope SFP in Figure 6, as well as an explanation of
the important controls.
1. Scope Graph: displays the waveforms specified in Channel 0 and Channel 1 as well as the cursors (see 9). The bottom of
the scope graph displays various signal characteristics (CH 0 Meas. and CH1 Meas.). These characteristics include root
mean square (RMS), frequency (Freq) and the peak to peak amplitude (Vp-p). These measurements are only shown if the
channel is enabled (see parts 2 and 8).
2. Channel Settings: as previously stated there are two oscilloscope channels Channel 0 and Channel 1. Channel settings
allow the user to specify the source signal that will be displayed for each channel. The choices include SCOPE CH 0 and
SCOPE CH 1 BNC input channels (see feature 4 in Table 1) or AI<07> input signal rows (see feature 2 in Table 2). The
Enabled box below the channel settings allow the user to specify which channels to display in the scope graph.
3. Probe and Coupling: The probe setting is dependent on what kind of probe is being used to measure the signal voltage. The
two available settings are 1 and 10. Unless specified, use the 1 setting. In some case the signal being measured is
the sum of a time-varying voltage and a DC signal. If the user chooses to display only the AC part of the signal then the
coupling setting can be changed to AC. This setting will display only the AC part of the signal. The AC setting is not
available for signals measured with the AI channels (See part 4).
4. Volts/Div (Vertical sensitivity) and Vertical Position: The Volts/Div knob or drop-down menu allows the user to choose the
y-axis (voltage axis) scale. The Vertical Position knob or numerical input allows the user to adjust the zero cross (or Y axis
positioning of the displayed waveform). The user is most likely to use this control when the waveform is the sum of time
varying signal and a DC signal (see part 3).
5. Trigger: This oscilloscope features triggered sweeps. A triggered sweep starts (begins data acquisition) at a selected point
on a trigger signal, providing a stable display. The scope has three settings: Immediate, in which there is no external trigger
signal and the data acquisition begins immediately; Digital, in which acquisition begins on the rising edge or fall edge
(Slope setting) of an external digital signal; Edge, in which data acquisition begins when an internal or external signal
crosses a specified threshold (Level (V) setting). For the Digital setting, the trigger signal source is the TRIG BNC input
channel (see feature 4 in Table 1). For the Edge setting, the choices of signal sources are the Chan 0, Chan 1 or the TRIG
BNC input channel.
6. Log: allows the user to take a snapshot of the waveform(s) displayed on the scope graph and save the waveform as a .csv
file which allows for the plotting of displayed waveforms in other programs such as Matlab and Excel.
7. Timebase (Horizontal sensitivity): The Time/Div control knob and menu allows the user to choose the time-axis scale.

8. Display Measurements: Allows the user to select which channel measurements to display at the bottom of the scope graph
(see part 1).
9. Cursor Settings: allows the user to display up to two cursors on the scope graph. The cursor position is then displayed at the
bottom of the scope graph. The cursors can be moved horizontally by clicking the cursor and dragging it along the time
axis. The user can also select which of the two channels, Chan 0 and Chan 1, are associated with the two cursors.


Figure 6. DMM SFP with important controls labeled

D. FGEN (Function Generator)
The function generator is a device that generates time varying waveforms. The NI ELVISmx Function generator is generally
used to generate a periodic voltage signal in the form of a sine wave, a triangular wave or a square wave. The function generator
output can be obtained via two routes: the FGEN BNC output channel (see feature 4 in Table 1) or the FGEN prototyping board pin
sockets (see feature 3 in Table 2). Shown below is the FGEN SFP in Figure 7, as well as an explanation of the important controls.
The FGEN signal is referenced with respect to GROUND.


Figure 7. FGEN SFP with important controls labeled


1. Frequency Display: displays the frequency of the output waveform. When the function generator is off, OFF is displayed.
2. Waveform Selectors: allows the user to select what type of waveform is generated. The choices are sine wave, triangular
wave and square wave.
3. Waveform characteristics: the characteristics of the output waveform can be selected by the user. These characteristics
include: Frequency, peak-to-peak amplitude, DC offset, duty cycle that is only enabled when square wave is selected as the
waveform type, and adjusts the turn-on to turn-off ratio of the wave, and the modulation type which controls the type of
modulation (Amplitude or Frequency with the corresponding inputs shown in feature 3 in Table 2). Note that the time-
varying component of the output waveform is symmetrical with a peak amplitude of one-half the peak-to-peak
amplitude.
4. Sweep Settings: The NI ELVIS II function generator has the capability to modulate the frequency automatically, based on
user specified Sweep Settings. The sweep setting controls include: Start Frequency which specifies the starting frequency
for the frequency sweep; Stop Frequency which specifies the frequency at which the frequency sweep stops; Step which
specifies the frequency interval between each frequency iteration during a frequency sweep; and Step Interval which
specifies the time interval for each frequency iteration (see part 7).
5. Manual Mode: The NI ELVIS II function generator allows the user to manually adjust the output waveform frequency and
amplitude (see feature 6 in Table 1). This mode should be used when a high accuracy of a time varying signal is desired or
if an undesired DC offset is observed when in automatic mode, even though the DC offset is set to zero.
6. Signal Route. Allows the user to select where to route the generated signal. The choices are the FGEN BNC output channel
(see feature 4 in Table 1) or the FGEN prototyping board pin sockets (see feature 3 in Table 2).
7. Sweep: allows the user to enable a frequency sweep (see part 4).
E. VPS (Variable Power Supply)
The variable power supply consists of two channels that supply adjustable output voltages from 0 to +12V on the SUPPLY+
channel and 0 to -12V on the SUPPLY- channel. The SUPPLY+ and SUPPLY- channels are available as prototyping board signal
rows (see feature 3 in Table 2). The output voltages are referenced to GROUND. Shown below is the VPS SFP in Figure 8, as well
as an explanation of the important controls.


Figure 8. VPS SFP with important controls labeled


1. Voltage Display: displays the output voltage of the SUPPLY+ and SUPPLY- signal rows when a Supply in automatic
mode. When a Supply in Manual mode, the Measure Supply Outputs control is visible. This control enables the displayed
of the selected manual voltage (see part 2). Otherwise the output voltage is not displayed when a supply is in Manual mode.
2. Manual Mode: The NI ELVIS II Variable Power Supply allows the user to manually adjust the output voltage (see part 1)
of the supply channels. Note that a Supply in automatic mode is not as accurate as a Supply in manual mode. As previously
stated in part 1, it is possible to display the manually adjusted output voltage by enabling the Measure Supply Outputs
control. Note that when the Measure Supply Outputs control is enabled, all other analog voltage measurements are
disabled, to include: DMM voltage measurements, Oscilloscope measurements and all cursor measurements.
3. Output voltage controls: allows the user to adjust the SUPPLY+ and SUPPLY- output voltages, when in automatic mode.
The RESET control allows the user sets the voltage of the Supply to zero.
4. Sweep Settings: The NI ELVIS II function generator has the capability to modulate the output voltage automatically, based
on user specified Sweep Settings. The sweep setting controls include: Supply Source which specifies on which Supply
channel the voltage sweep is executed; Start Voltage which specifies the starting output voltage for the voltage sweep; Stop
Voltage which specifies the voltage at which the voltage sweep stops; Step which specifies the voltage interval between
each voltage iteration during a voltage sweep; and Step Interval which specifies the time interval for each voltage iteration
(see part 5).
5. Sweep: allows the user to begin a voltage sweep (see part 4).
F. Bode (Bode Analyzer)
A bode analyzer describes the frequency response of a circuit-under-test (e.g. a low pass RC filter) by displaying the Gain (in
dB) and Phase (degrees) of the circuit-under-test as a function of frequency. The NI ELVISmx Bode analyzer uses the Function
generator to output a stimulus and then uses two input channels to measure the circuit response and stimulus and computes the Gain
(in dB) and Phase (degrees) of the system under test based on the measured signals. The FGEN signal row (see Section D) and a
GROUND signal row is connected to the AI 1 signal rows. The signal output and a GROUND signal row is connected to AI 0
signal rows. Shown below is the Bode SFP in Figure 9, as well as an explanation of the important controls.



Figure 9. Bode SFP with important controls labeled



1. Gain Display: displays the Bode gain (in dB) and Bode phase (in degrees) graphs for the circuit under test. These signals
are plotted against frequency measured in Hz. Also displayed, if enabled, are measurement cursors that can be moved
horizontally by clicking any cursor and dragging it along the frequency axis
2. Measurement Settings: As previously stated a bode plot is the representation of the response of a circuit at different
frequencies in terms of gain and phase. For this reason, a frequency sweep must be performed. The NI ELVISmx Bode
analyzer sweeps the frequency in a logarithmic fashion as opposed to linear fashion (i.e. the logarithm of the frequency is
swept linearly instead of the actual frequency). These controls allows the user to specify the sweep parameters in terms of:
Start Frequency which specifies the starting frequency for the frequency sweep; Stop Frequency which specifies the
frequency at which the frequency sweep stops; Step (per decade) which specifies the number of evenly spaced points to
sweep per decade (A decade in the logarithmic sense represents multiplication by 10 from the previous value); Peak
Amplitude which specifies the peak amplitude of the stimulus (the FGEN output signal). It is recommended that a high
amplitude signal be used to drive passive circuits for improved accuracy and a relatively smaller signal be used to drive
circuits with high gain to avoid saturating the circuit; Op-amp Signal polarity which can be Normal or Inverted, and allows
Select Inverted to invert the measured values of the stimulus signal during Bode analysis. This choice affects only the phase
plot and is used to zero the phase shift for an inverting circuit.
3. Graph Settings: This set of controls allows the user to select between a linear and logarithmic scale for the Gain graph. The
default is logarithmic.
4. Cursor Settings: These set of controls give the user the choice of enabling measurement cursors on the Gain and Phase plots
and precise control of the cursors via the Left and Right buttons (see part 5)
5. Measurement display: displays the gain (linear and in dB), phase and frequency of the current measurement point during a
frequency sweep or cursor movement (see part 4).
G. DSA (Dynamic Signal Analyzer)
The dynamic signal analyzer is an instrument performs a frequency domain transform of a signal. The NI ELVISmx Dynamic
Signal Analyzer consists of a single channel, which can automatically connect to up to ten (10) sources. It can continuously makes
measurements or take a signal scan. Shown below is the DSA SFP in Figure 10, as well as an explanation of the important controls.

Figure 10. DSA SFP with important controls labeled

1. Frequency domain display: displays the frequency domain representation of the input signal with a plot of magnitude (see
part 5 for selection of units) against frequency. Also displayed is the Detected Fundamental Frequency (in Hz) based on
full harmonic analysis. The Fundamental Frequency Power is an estimate of the power of the fundamental frequency peak

over a span of three frequency lines (see part 5 for selection of units). The Mode drop down menu specifies whether to
display the power spectrum or the power spectral density of the input signal. THD (%) displays the measured harmonic
distortion as a percentage relative to the fundamental power. SINAD (dB) displays the measured Signal in Noise and
Distortion (SINAD).
2. Time domain display: displays the input signal in the time domain. Vpk (V) displays the difference between the measured
maximum and minimum voltage level of the input signal.
3. Input Settings: allows the user to specify the source and the expected voltage range of the input signal. The input channel
sources are SCOPE CH <0..1> (see feature 4 in Table 1) and AI<0..7> (see feature 2 in Table 2).
4. FFT Settings and Averaging: specifies the settings for the fast Fourier transform and averaging options respectively. The
options are Frequency span which specifies the measurement range that starts from DC and extends to the selected value;
Resolution which specifies length of the time domain record and the number of samples to be acquired; Window which
specifies the time-domain window to use; Mode which specifies the averaging mode. The choices are Vector, RMS and
Peak-Hold; Weighting which specifies the weighting mode for RMS and Vector averaging. The choices are linear and
Exponential; and # of Averages which specifies the number of averages that is used for RMS and Vector averaging.
5. Frequency Display and Scale Settings: specifies the display and scale settings for the frequency domain display. The
options are Units which specifies the units for the magnitude scale of the frequency domain display; Mode which specifies
the display mode for the magnitude scale of the frequency domain display and the Fundamental Frequency Power indicator;
Averaging which specifies if the selected averaging process should be restarted.; Scale which specifies how the magnitude
range adjusts automatically to the input data.; Maximum and Minimum which specifies the maximum and minimum
magnitude value on the frequency domain display respectively.
6. Cursor Settings: These set of controls give the user the choice of enabling measurement cursors (Cursors On) on the
frequency domain and time-domain displays and precise control of a selected cursor (Cursor Select) via the Left and Right
buttons.
H. ARB (Arbitrary Waveform Generator)
The arbitrary waveform generator allows the user to create a variety of signal voltage types using the Waveform Editor software
and output the created signals via the analog output channels AO <01> (see feature 3 in Table 2). The presence of two output
channels allows for the simultaneous generation of two waveforms. . Shown below is the ARB SFP in Figure 11, as well as an
explanation of the important controls.

Figure 11. DSA SFP with important controls labeled


1. Waveform Display: displays the created signal loaded from the Waveform Editor. The Display menu allows the user to
choose between a time domain or frequency domain representation of the created signal. Update Rate displays the actual
hardware update rate. If there is no generation present on any channel, the display provides an OFF message.
2. Waveform Settings: allows the user to specify the settings for the output waveforms. The user can enable Channels AO
<01> (using the Enabled box). When a waveform is loaded, the filename is displayed under Waveform Name, otherwise
<empty> is displayed. The user can specify the path of the loaded waveform using the file icon. Gain specifies a scaling
factor form the loaded waveform.
3. Waveform Editor: Launches the Waveform Editor (Help for the Waveform editor is beyond the scope of this manual).
4. Generation Mode: specifies the signal generation mode, Select Run Continuously to generate a continuous signal or Run
Once to generate single (one-shot) signal.
5. Timing and Triggering Settings: allows the user to specify settings for number of samples to generated per second (Update
Rate) and the Trigger source (see part 5 of Scope SFP).

I. DigIn (Digital Reader)
The NI ELVISmx II Digital Reader SFP allows the user to read digital data from eight consecutive lines at a time. This
instrument is a software (virtual) form of the user configurable LEDS shown in feature 7 in Table 2. The eight consecutive lines
could be either the DIO<07>, DIO <815>, or DIO<1623> signal rows (see feature 6 in Table 2). Shown below is the DigIn
SFP in Figure 12, as well as an explanation of the important controls.


Figure 12. DigIn SFP with important controls labeled

1. Display Window: displays the current value read from the DIO lines (Line States) as well the numerical representation of
the line states (Numerical Value).This representation can be changed via the radix selector. The set of 8 consecutive lines
read can be specified by the user.
2. Configuration Settings: Specifies the set of 8 consecutive DIO Lines through which data is being read.
3. Acquisition Mode: specifies the execution mode, Select Run Continuously to continuously read the digital or Run Once for
single signal acquisition.


J. DigOut (Digital Writer)
The NI ELVISmx II Digital Writer SFP allows the user to write specified TTL compatible digital data to eight consecutive lines
at a time. The specified data may be in the form of manually created patterns or predefined patterns such as ramp toggle and
walking 1s. The eight consecutive lines could be either the DIO<07>, DIO <815>, or DIO<1623> signal rows (see feature 6
in Table 2). The output of the Digital Writer stays latched (at the last created value) until another pattern is output, the lines it is
using are configured for digital data reading, or the power is cycled on the NI ELVIS workstation. Shown below is the DigOut SFP
in Figure 13, as well as an explanation of the important controls.
1. Display Window: displays the current value written to the DIO lines (Line States) as well the numerical representation of
the line states (Numerical Value).This representation can be changed via a radix selector.
2. Lines to write: Specifies the set of 8 consecutive DIO Lines through which data is being read.
3. Pattern: specifies the pattern output to the DIO bus. These patterns are: Manual, which will allows the user to manually
switch between HI and LO for an output line via the Manual Pattern control; mode and Ramp, Alternating 1/0s and
Walking 1s, which are predefined patterns. The Manual Pattern control is disabled a pattern othen Manual is selected in
the Pattern.
4. Manual Pattern actions: The manual patterns actions are disabled when a pattern other than Manual is enabled. These
actions perform a logical negation (Toggle), a one-bit logical rotation (Rotate), or a one-bit logical shift of the current
pattern created by the user (Shift). The direction of the one-bit logical rotation or one-bit logical shift is specified by the
user (direction).


Figure 13. Digout SFP with important controls labeled

K. Imped (Impedance Analyzer)
The Impedance Analyzer is a device capable of measuring the resistance and reactance of a passive two-wire element at a given
frequency. The device is commonly used as an aid to explaining sinusoidal steady state analysis (i.e. used to compute amplitude and
phase changes of sinusoidal alternating current going through a passive two-wire element). To measure the test circuit, the two
wires of the element are connected to DUT+ and DUT- signal rows of the NI ELVISmx prototyping board (see feature 3 in Table
2). Shown below is the Imped SFP in Figure 14, as well as an explanation of the important controls.


Figure 14. Imped SFP with important controls labeled
1. Display Window: displays the impedance values of the device-under-test via a display of the magnitude of the measured
impedance as well as its components (Resistance and Reactance) in a polar plot; and a numerical representation of the
Magnitude, Phase, Resistance component and Reactance component of the measured impedance.
2. Measurement Frequency: allows the user to specify the frequency used to measure the resistance and reactance of the
device-under-test.
3. Graph Settings: allows the user to specify the graph settings in terms of the visible polar plot quadrants (Visible Section)
and whether the scales in the polar plot are linear or logarithmic (Mapping).
L. 2-Wire (Two-Wire Voltage Analyzer)
The two-wire voltage analyzer is used to conduct parametric testing of diodes in the form of current-voltage curves. A common
use for this device is the determination of the forward-bias voltage and small signal resistance for the piece-wise approximation of a
test diode. To measure the test circuit, the anode and cathode of the diode are connected to DUT+ and DUT- signal rows of the NI
ELVISmx prototyping board respectively (see feature 3 in Table 2). A voltage signal is applied across the diode (DUT+ and DUT-)
as a stimulus and the resulting diode current is measured. Shown below is the 2-Wire SFP in Figure 15, as well as an explanation of
the important controls.
1. Display Window: displays the current (in mA) vs. voltage (in V) plot for the device-under-test as well as user-enabled
cursors.
2. Measurement display: displays the Current (mA) and Voltage (V) of the current measurement point during a voltage sweep
or cursor movement (see part 3).
3. Voltage Sweep: allows the user to specify the voltage sweep settings in terms of the voltage to start the sweep (Start); the
voltage spacing between measurements during the voltage sweep (Increment); and the voltage to stop the sweep (Mapping).
4. Current Limits: allows the user to specify the maximum positive and negative current allowed during the voltage sweep.
5. Gain Settings: allows the user to specify the gain of the internal current measurement circuit. Increasing the Gain increases
the characteristic curve accuracy but reduces the maximum measurable current and takes a longer time to plot.
6. Graph Settings: allows the user to specify the scales of the X- and Y- axis of the plot are linear or logarithmic (Voltage
Mapping and Current Mapping).



Figure 15. 2-Wire SFP with important controls labeled

3-Wire (Three-Wire Voltage Analyzer)
The three-wire voltage analyzer is used to conduct parametric testing of transistors in the form of characteristic curves. To
measure the test circuit, the Base, Collector and Emitter of the diode are connected to BASE, DUT+ and DUT- signal rows of the
NI ELVISmx prototyping board respectively (see feature 3 in Table 2). A voltage signal is applied across the collector-emitter
junction (DUT+ and DUT-) and a current is applied discretely to the base as stimuli and the resulting collector current is measured.
Shown below is the 3-Wire SFP in Figure 16, as well as an explanation of the important controls.

Figure 16. 3-Wire SFP with important controls labeled


1. Display Window: displays the collector current (in mA) vs. the collector voltage (in V) and the base current (in uA) plot for
the device-under-test as well as user-enabled cursors.
2. Measurement display: displays the Collector Current (mA), Base Current (uA) and Collector Voltage (V) of the current
measurement point during a voltage sweep or cursor movement (see part 3).
3. Transistor Type: allows the user to specify the type of transistor under test.
4. Base Current Iteration: allows the user to specify number of base current curves for the transistor characteristic curve in
terms of the start value of the base current curves (Ib Start); the spacing between each base current curve for the transistor
characteristic curve (Ib Step); and the number of base current curves to generate (Number of Curves).
5. Collector Voltage Sweep: allows the user to specify the voltage sweep settings in terms of the voltage to start the sweep (Vc
Start); the voltage spacing between measurements during the voltage sweep (Vc Step); the voltage to stop the sweep (Vc
Stop); and the maximum collector current allowed during the voltage sweep (Ic Limit).







1

NI ELVIS II Pinout Description
Pin Number SIDE A SIDE B
1 +15V -15V
2 +15V -15V
3 +5V GROUND
4 +5V GROUND
5 +5V GROUND
6 GROUND GROUND
7 DIO 6 DIO 7
8 DIO 4 DIO 5
9 DIO 2 DIO 3
10 DIO 0 DIO 1
11 GROUND GROUND
12 NC NC
13 NC NC
14 DIO 14 DIO 15
15 DIO 12 DIO 13
16 DIO 10 DIO 11
17 DIO 8 DIO 9
18 GROUND GROUND
19 BoardID6 BoardID7
20 BoardID4 BoardID5
21 BoardID2 BoardID3
22 BoardID0 BoardID1
23 GROUND GROUND
24 NC DIO 23
25 DIO 22 DIO 21
26 DIO 20 DIO 19
27 DIO 18 DIO 17
28 DIO 16 SB_PRES
29 NC PFI 6
30 PFI 5 PFI 7
31 PFI 2 PFI 10
32 PFI 11 PFI 1
33 PFI 0 PFI 3
34 PFI 4 PFI 13
35 PFI 8 PFI 9
36 PFI 12 PFI 14
37 GROUND GROUND
38 reserved reserved
39 AIGND AIGND
40 AI 7+ AI 7-


2





41 AI 6+ AI 6-
42 AI 5+ AI 5-
43 AI 4+ AI 4-
44 AIGND AIGND
45 AI 3+ AI 3-
46 AI 2+ AI 2-
47 AI 1+ AI 1-
48 AI 0+ AI 0-
49 AISENSE NC
50 KEYWAY KEYWAY
51 KEYWAY KEYWAY
52 NC NC
53 SYNC FM
54 FGEN AM
55 GROUND VCC
56 NC GROUND
57 DUT- NC
58 Base DUT+
59 GROUND GROUND
60 AO0 AO1
61 GROUND GROUND
62 Supply- Supply+


3

NI ELVIS II Signal Description
Signal Name Type Description
+15V DC Power Supplies +15 V Fixed Power Supply
-15V DC Power Supplies -15 V Fixed Power Supply
+5V DC Power Supplies +5 V Fixed Power Supply
GROUND DC Power Supplies Ground
DIO<0..23> Digital input/output Digital Lines P0.0 through P0.23
These channels are general purpose
DIO lines that are used to read or write
data.
BoardID<0..7> These eight lines signify the unique ID
of each type of prototyping board by
shorting them to VCC or to GROUND.
SB_PRES This signal is used to indicate whether
the prototyping board is inserted
completely or not. It should be
connected to VCC directly without the
pull-up resistor.
PFI <0..2>,
<5..7>,<10..11>
Programmable Functions
Interface
PFI Lines
PFI 8 Programmable Function
Interface
PFI Lines - Default function: Counter 0
Source
PFI 9 Programmable Function
Interface
PFI Lines - Default function: Counter 0
Gate
PFI 12 Programmable Function
Interface
PFI Lines - Default function: Counter 0
Out
PFI 3 Programmable Function
Interface
PFI Lines - Default function: Counter 1
Source
PFI 4 Programmable Function
Interface
PFI Lines - Default function: Counter 1
Gate
PFI 13 Programmable Function
Interface
PFI Lines - Default function: Counter 1
Out
PFI 14 Programmable Function
Interface
PFI Lines - Default function: Frequency
Output
AIGND Analog Inputs Analog Input Ground Ground
reference for the Analog Input signals.
AI <0..7> Analog Inputs

Analog Input Channels 0 through 7
Positive and negative input channels
lines to differential AI channels.


4





AI SENSE Analog Inputs Analog Input Sense Reference for
the analog channels in nonreferenced
single-ended (NRSE) mode.
FGEN Function Generator Function Generator Output
SYNC Function Generator TTL output synchronized to the FGEN
signal.
AM

Function Generator

Amplitude Modulation Input Analog
input used to modulate the amplitude of
the FGEN signal.
FM

Function Generator

Frequency Modulation Input Analog
input used to modulate the frequency of
the FGEN signal.
Base 3-Wire Voltage/Current
Analyzer
Base excitation for bipolar junction
transistors.
DUT+ DMM, Impedance, 2- and
3-Wire Analyzers
Excitation terminal for Capacitance and
Inductance measurements (DMM),
Impedance Analyzer, 2-Wire Analyzer,
and 3-Wire Analyzer.
DUT- DMM, Impedance, 2- and
3-Wire Analyzers

Virtual ground and current
measurement for capacitance and
inductance measurements (DMM), the
Impedance Analyzer,2-Wire Analyzer,
and 3-Wire Analyzer.
AO <0..1> Analog Outputs

Analog Output Channels 0 and 1
Used for the Arbitrary Waveform
Generator.
VCC Pull-up signal +5V Pull-up signal
SUPPLY+

Variable Power Supplies

Positive Variable Power Supply
Output of 0 to 12 V.
SUPPLY Variable Power Supplies

Negative Variable Power Supply
Output of 12 to 0 V.


5

Note: All the PFI lines can be configured as static digital I/O or Counter/Timer.
When PFI lines are configured as Static Digital I/O, the mapping relationship in DAQmx is as
follows:
PFI<0..7> to P1.<0..7>
PFI<8..14> to P2.<0..6>

The diagram below shows the pin order of the connector with side B visible.

Vous aimerez peut-être aussi