Findings

1.0 FAKULTI KEJURUTERAAN AWAM

No. 1 Location: Laboratory and Stores Pic No: Civ-01a Pic No: Civ-01a

Evaluation Item: Racks

Observation: Inadequate equipments racks.

Recommendation: Proposed sufficient racks for the


storage equipment and raw material.
Proposed to separate equipment store and raw material
store.

No. 2 Location: Workshop Pic No: Civ-02a Pic No: Civ-02b

Evaluation Item: Machinery

Observation: Location of Machinery not suitable and


safe place.

Recommendation: Proposed suitable location for keep


machine safe and the root for this machine must have
ramp.

No. 3 Location: Workshop Pic No: Civ-03a

Evaluation Item: Drain

Observation: Good example of drain roots.

Recommendation: To follow the design of the drain


roots as observed.

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 1 of 7
Findings

No. 4 Location: Outside Workshop Pic No: Civ-04a Pic No: Civ-04b

Evaluation Item: Wastes

Observation: Not dedicated area for wastes

Recommendation: Proposed suitable area for hard and


big waste and raw material.
Proposed the waste location near to loading area with
ramp. So the waste easily to move.

No. 5 Location: Outside building Pic No: Civ-05a

Evaluation Item: Air-Conditioning

Observation: Air-Conditioning outdoor located to high


from ground level.

Recommendation: Proposed accessible location for air-


conditioning compressor

No. 6 Evaluation Item: Roller Shutter Pic No: Civ-06a

Observation: Good example - Roller Shutter near to


loading area and have ramp

Recommendation: To adapt design

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 2 of 7
Findings

No. 1 Evaluation Item: Information Board Pic No: Elec-01a

Observation: Improper information board

Recommendation: Proposed information board with


glass for every labs, classrooms, workshop, lecturers
room and lecturers hall.

2.0 FAKULTI KEJURUTERAAN ELEKTRIK


No. 2 Evaluation Item: Lighting Pic No: Elec-02a

Observation: Lamps was fitted to high and difficult to


access

Recommendation: Proposed design which allow better


accessible.
Eg. – lowered the lamp fitting.

No. 3 Evaluation Item: Electronic Lab, Fakulti Elektrik Pic No: Elec-03a

Observation: Good example of floor

Recommendation: To adapt design

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 3 of 7
Findings

No. 4 Evaluation Item: High Efficiency Labs Pic No: Elec-04a Pic No: Elec-04b

Observation: Require temperature and humidity control


feature

Recommendation: To adapt spec for data centre

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 4 of 7
Findings

3.0 FAKULTI KEJURUTERAAN MEKANIKAL

No.1 Evaluation Item: Hazardous Wastes Pic No: Mech-01a Pic No: Mech-01b

Observation: Hazardous waste are located at open area

Recommendation: Proposed specific locations, grill and


locked with danger signboard. So nobody can access the
hazardous wastes alert with it.

No. 2 Evaluation Item: Critical Heavy Equipment Pic No: Mech-02a Pic No: Mech-02ab

Observation: Critical machine doesn’t have redundant


power supply, where the function is to protect the
machine and avoid from damages in case of power failure

Recommendation: Proposed redundant power supply on


every critical machine

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 5 of 7
Findings

4.0 FAKULTI PENGURUSAN HOTEL

No. 1 Evaluation Item: Kitchen Fire Fighting Pic No: Hotel-01ª Pic No: Hotel-01b

Observation: Kitchen not equip with Fire Fighting


System

Recommendation: Install Fire Fighting System

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 6 of 7
Findings

No. 2 Evaluation Item: Locker Pic No: Hotel-01ª

Observation: Lack of Student Locker

Recommendation: Proposed sufficient locker for student


keep their things while in the workshop or lab

Use or disclosure of data/ information from this document is strictly prohibited without written permission o f Global Facilities Management Sdn
Bhd Page 7 of 7