The average air/oil mixture contains 3.8 106 to 1 air to oil vapor by volume. Piping from the air/oil
separator must allow continuous drainage of any fluids that may collect in the line and must include a
cleanable flame arrestor if discharged into the exhaust duct. The maximum allowable loads on the
Air/oil separator connecting flange are: 300 LB shear, 300 LB axial, and 345 in-LB bending moment.
http://inside-aep.ps.ge.com/insideaep/aep/iad/engine_prod_delv/idms/lm2500/09lubevent.... 19/11/2005
Lubrication
Page 2 of 4
When negative pressure package ventilation system is utilized, the gas generator bearing sump oil seal
pressure level is reduced because the aspirator inlet pressure is reduced. The compressor rear frame vent
pressure is also resuced. The sump vent pressure is not reduced, as it ultimately discharges to ambient
through the exhaust or other systems. The differential pressure across the oil seals is therefore
compromised; causing potential oil leakage at idle, and possible pressure reversal during engine load
rejections and trips from high power. This pressure reversal can cause sudden oil vapor discharge from
the compressor rear frame vents. The pressure reversal can be prevented by installing a Sump
Evacuation System (SES) in the air/oil separator discharge line. The SES can reduce the internal sump
pressure by 0.8 to 1.3 psi and thereby increase the seal pressure differential.
The SES consists of an electric motor driven pump installed in the air/oil separator discharge line, and is
operated during low gas generator speed operation and during drop load transients. During normal
operation above 9000 rpm gas generator speed the pump is turned off and the vent air simply flows
through the pump.
http://inside-aep.ps.ge.com/insideaep/aep/iad/engine_prod_delv/idms/lm2500/09lubevent.... 19/11/2005
Lubrication
Page 3 of 4
The design requirements for such a system and pump are as follows:
z Temperature Capability = 350F
z Air / oil ratio = 3.8 106 to 1
z
z
z
z
Maintain a flow rate of 100 cfm through gas generator speed range
Reduce its inlet pressure by 0.8 to 1.3 psi when operating
Maximum pressure drop when not operating not to exceed 0.3 psi
Electric motor driven
The pump should be operated during gas generator speeds of 1600 - 9000 rpm, whether motoring or
operating, and during rapid deceleration as load rejections or emergency shutdowns. A recommended
operating sequence for such a pump is shown below.