Vous êtes sur la page 1sur 17

Traders & Exporters of Power Equipments and Power Consultancy

Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
Ref : LIPS/CIPL/Quo/724 March 18, 2014
M/s Cabcon India Pvt Ltd,
Room No. - 21, 4 A, Pollock Street,
Swaika Center, Ground Floor.
Kolkata - 700001, West Bengal, India
Kind Attn: Mr. JAWED AALAM
Subject: YOUR REQUIREMENT OF 11KV/33KV ELECTRICAL EQUIPMENTS FOR YOUR NESCL/NTPC/CS-
DA-628, DARLIPALI, ODISHA PROJECT TENDER.
Dear Sir,
We have come to know from some reliable sources that you have some requirement of 11KV/33KV Electrical
Equipments for your NESCL/NTPCCS-DA-628 for Darlipali, Odisha Project Tender. We are pleased to submit our
most Competitive OFFER for the same on the terms and conditions as under:
PRICES : The quoted Prices are FIRM & Variable for Power Transformers, Cables & Conductors.
SCHEDULE OF QUANTITY AND PRICES ( BOUGHTOUT ITEMS) (SCHEDULE - 2A)
Name of Bidder LUCKY INDIA POWER SOLUTIONS, GHAZIABAD
Sr.
No
DESCRIPTION Unit Qty UNIT EX
WORKS
PRICE
(Rs.)
ED
@10.30%
CST
@2%
Unit Frt
Charges
(Rs.)
Unit
Total
Prices
(Rs.)
Total
FOR
Prices
(Rs.)
A 33/11 KV DARLIPALI SUB STATION
1
36 kV, Off Load Isolator along with Earth switch,
100A, 12.5 kA rms
set 2 33303 0 666 2498 36467 72934
2
30 kV Lightning arrestor Nos 6 4809 0 96 361 5266 31595
3
2 pole (11mtr Joist/Steel Tubular Pole SP 56)
structure for mounting of 33kv isolator, earth
switch etc
set 2 17974 0 359 1348 19682 39363
4
33 KV Ring Mains Unit (RMU) as per Single line
diagram, each comprising of
set 3 235645 0 4713 17673 258031 774094
i)
1 No. 33KV Ring Main unit, Non-extensible,
Manually operated, consisting of 2 No. Load
break switches (100 Amps) and 1 No. circuit
breaker (400 Amps) for transformer feeder
along with earth switches each for load break
switch and circuit breaker
ii)
33KV Metering (0.2s accuracy class)
iii)
HT Cable Terminations and
iv)
Internal cabling for connections between the
equipments of RMU, lighting & earthing system
along with required hardware, gaskets, gland
plates etc as required
5
3.15 MVA, 33/11kV, Power Transformer, ONAN
with neutral CT
Nos 3 1853000 190859 40877 138975 2223711 6671134
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
6
11 KV Ring Mains Unit (RMU) as per Single line
diagram, each comprising of
set 3 420795 0 8416 31560 460771 1382312
i)
Galvanized Steel sheet enclosure of 1.6mm
minimum thickness with steel base frame for
RMU
ii)
11KV Ring Main unit, Non-extensible, Manually
operated, consisting of 2 Nos. Load break
switches (400 Amps) and 2 Nos. circuit breakers
(400Amps) for transformer feeder along with
earth switches
iii)
HT Cable Terminations and
iv)
Internal cabling for connections between the
equipments of RMU, lighting & earthing system
along with required hardware, gaskets, gland
plates etc as required
7
19/33 kV grade, XLPE, A1 conductor PVC
sheathed, armoured 1Cx150 sq. mm Cable
Mtr 500 432 0 9 32 473 236520
8
6.35/11 kV grade, XLPE, A1 conductor PVC
sheathed, armoured 1Cx300 sq. mm Cable
Mtr 800 417 0 8 31 457 365292
9
33kV Cable terminations
a)
Indoor Nos 27 5094 0 102 382 5578 150604
b)
Outdoor Nos 18 3411 0 68 256 3735 67231
10
11kV Cable terminations 0
a)
Indoor Nos 27 4509 0 90 338 4937 133309
b)
Outdoor Nos 45 2758 0 55 207 3020 135900
11
11kV, 200 KVAR Capacitor banks suitable for
outdoor installation and complete in all respects
including fuse, mounting racks
set 2 90170 0 1803 6763 98736 197472
12
33/11KV substation Misc. items like conductor,
hardware, insulators, clamp connectors etc
Lot 1 300568 0 6011 22543 329122 329122
13
Earthing (earthmat)as per TS set 1 153741 0 3075 11531 168346 168346
14
Fire Fighting System CO2 type/CTC type/dry
type as per TS
Lot 1 18635 0 373 1398 20405 20405
15
Testing Instruments as per TS Lot 1 0 0 0 0 0 0
16
S/s Chain Link Fencing and Gate as per TS Nos 1 0 0 0 0 0 0
17
Lighting Mast (30 meter) as per TS Nos 16 5230 0 105 392 5727 91630
18
LT AB Cable 4Cx16sqmm, Aluminium conductor
with armour for Lighting Mast
Mtr 1000 9131 0 183 685 9998 9998445
19
33 kv Metering cublicle with 0.2s accuracy class
meter with matching CT PT (Indoor type) as per
TS
Nos 2 60000 6180 1324 4500 72004 144007
B
PACKAGED SUB STATIONS
20
11 kV Lightning arrestor Nos 57 2164 0 43 162 2370 135066
21
11 kV, 3, 50 A On load Isolator Nos 19 22242 0 445 1668 24355 462745
22
2 pole (11mtr Joist/Steel Tubular Pole SP 56)
structure for mounting of 11kv isolators etc
set 19 17974 0 359 1348 19682 373949
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
23
LT Packaged Substation each comprising of set 6 1538906 0 30778 115418 1685102 10110612
i)
Galvanized steel sheet enclosure with steel base
frame for overall Packaged substation.- 1 set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches (400A) and 1 No. circuit breaker
for transformer feeder (400A) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No.
iv)
Low voltage bus bar system 1 set.
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker (Fixed
type 3 pole with fully isolable neutral link)
1 No, Incomer 800 A, MCCB (with necessary
mechanical interlocks between the Incomer
breaker and breaker for emergency use)
2 Nos. 400A TPN MCCB
2 Nos. 200A TPN MCCB +1 No MCCB( suitable
for switching of 100 KVAR Capacitor Bank)
2 Nos.100 A TPN MCCB
vi)
415 V, 100 KVAR Capacitor Banks with 4
step(minimum) APFC relay
vii)
415V Metering (0.5 class)
viii)
HT cable treminations
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
24
LT Packaged Substation set 13 1262384 0 25248 94679 1382310 17970036
LT Packaged Substation each comprising of
i)
Galvanized steel sheet enclosure with steel base
frame for overall Packaged substation.- 1 set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches(400 A) and 1 No. circuit breaker
for transformer feeder (400) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No
iv)
Low voltage bus bar system 1 set
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker ,20 KA
for 1 sec
2 Nos. 400A TPN MCCB ,20 KA
2 Nos. 200A TPN MCCB ,20 KA
2 Nos.100 A TPN MCCB ,20 KA
1 No. MCCB suitable for switching of 20 KVAR
Capacitor Bank
vi)
415 V, 20 KVAR Capacitor Bank without APFC
vii)
415V Metering (Class 0.5)
viii)
HT cable terminations
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
25
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx95 sq. mm Cable
Mtr 1000 546 0 11 41 598 597870
26
11 kV, 300A poles mounted Isolator (3 phase)
OFF LOAD
Nos 7 22242 0 445 1668 24355 170485
27
11 kV Lightning arrestor Nos 9 2164 0 43 162 2370 21326
28
11KV DO fuse, 160 A set 1 6011 0 120 451 6582 6582
C
33 KV line
29
ACSR DOG 100 sq mm ( 7/4.26) conductor as
per TS
KM 131 70850 0 1417 5314 77581 10163078
30
11mtr. Joist Pole with pin and strain insulators,
earthing arrangement , material for concrete
foundation, danger plate,preformed insulator
bindings, performed jointing sleeves , fasteners
& washers, and required hardware, complete (
as per TS)
a)
11mtr. MS Joist MT 209 17974 0 359 1348 19682 4113440
b)
GI Material MT 14 57709 0 1154 4328 63191 884679
c)
Nuts and Bolts MT 3 54102 0 1082 4058 59242 177725
d)
11 KV Disc Insulator 70 KN Nos 4608 283 0 6 21 310 1427950
e)
Disc Insulator Hardware fittings Nos 4608 421 0 8 32 461 2124265
f)
Helical fitting for 11 KV Disc Insulator Nos 4608 469 0 9 35 514 2366461
g)
33 KV PIN Insulator Nos 120 228 0 5 17 250 29959
h)
GI Pin for Pin Insulator Nos 120 234 0 5 18 256 30748
i)
Pipe Earthing 32NB Medium class as per IS
1161,2500mm GI Pipe
Nos 512 0 0 0 0 0 0
j)
PG Clamps/Jointing sleeve Nos 240 132 0 3 10 145 34690
k)
Danger Board Nos 472 78 0 2 6 85 40314
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
l)
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 472 1850 0 37 139 2026 956154
D
HT CABLE
31
19/33 KV grade XLPE,Al conductor PVC
sheathed,armoured Cable 3Cx240 sqmm
KM 3.5 1666 0 33 125 1824 6385
32
Cable Termination and Jointing Kits Outdoor Nos 18 5094 0 102 382 5578 100403
33
Cable Termination and Jointing Kits Indoor Nos 2 3411 0 68 256 3735 7470
34
HDPE Pipe 150mm Mtr 500 0 0 0 0 0 0
E
11 KV OVER HEAD LINES WITH STEEL TUBULAR
POLE
35
11 meter steel Tubular pole type designation:
410-SP-56
a)
Four poles.(sets) Nos 34 118772 0 2375 8908 130055 4421882
b)
Double pole.(sets) Nos 6 51247 0 1025 3844 56115 336693
c)
Single pole.(sets) Nos 70 29005 0 580 2175 31760 2223233
36
M.S. Angle, channel flat. GI nuts and bolts etc.
for cross arms, cross bracing clamps, pole top
bracket etc
a)
Four poles.(sets) Nos 34 54102 0 1082 4058 59242 2014217
b)
Double pole.(sets) Nos 6 37270 0 745 2795 40811 244864
c)
Single pole.(sets) Nos 70 19236 0 385 1443 21063 1474439
37
Protective guard wire complete with galvanized
steel wire. Cross arm channel for road crossing
set 5 0 0 0 0 0 0
38
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 218 1803 0 36 135 1974 430394
39
Danger plate/number plate set 110 78 0 2 6 85 9395
40
Earthing of pole complete with spike earthing,
earth wire, salt and charcoal coke as per TS
set 218 10219 0 204 766 11190 2439377
41
11KV disc insulator complete with galvanized
insulator fittings, ball and socket type and
complete with galvanized strain, clamp bolts
nuts and washer
set 297 703 0 14 53 770 228626
42
11KV pin insulators, complete with G.I. Pin,
nuts, bolts and washer
Nos 489 343 0 7 26 376 183661
43
ACSR Racoon conductor KM 23 54391 0 1088 4079 59558 1369837
44
Mid span joints & PG Clamp Nos 50 493 0 10 37 540 26992
45
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx240 sq. mm Cable with
Screen fault current of 3 kA
KM 2 981 0 20 74 1074 2148
46
11 kV Cable terminations kit, 3 phase, Outdoor
type
Nos 10 2758 0 55 207 3020 30200
F
11KV BAY WORKS
47
11 KV, 3Ph VCB, 800 A with structure Nos 1 240454 0 4809 18034 263297 263297
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
48
11 KV, 3Ph isolator, 800 A Nos 2 22242 0 445 1668 24355 48710
49
Single Phase 11 KV Current Transformer Nos 3 11500 1185 254 863 13801 41402
50
Single Phase 11KV Potential Transformer Nos 3 10500 1082 232 788 12601 37802
51
Indoor Control & Relay Panel for 11KV feeder
with Energy Meter as per TS
Nos 1 180341 0 3607 13526 197473 197473
52
ACSR DOG 100 sq mm ( 7/4.26) conductor as
per TS
KM 0.05 70850 0 1417 5314 77581 3879
53
11kV,400A, 3Ph AB Switch for Outgoing DP set 1 6973 0 139 523 7635 7635
54
11 kV Lightning arrestor Nos 3 2164 0 43 162 2370 7109
55
Junction Box for CT (1 JB common for 3 phases)
for bay augmentation as per TS
Nos 1 4500 0 90 338 4928 4928
56
Junction Box for PT (1 JB common for 3 phases)
for bay augmentation as per TS
Nos 1 4500 0 90 338 4928 4928
57
Insulator, Hardware fittings, Clamps,
Connectors, Lugs, Ferrules for bay
augmentation works in substations as per TS
LS 1 240454 0 4809 18034 263297 263297
58
3Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 75 95 0 2 7 104 7802
59
5Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 141 0 3 11 154 7720
60
7Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 185 0 4 14 203 10129
61
4Cx10 sqmm PVC, armoured Aluminium power
cable
Mtr 40 60 0 1 5 66 2628
62
4Cx6 sqmm PVC, armoured Aluminium power
cable
Mtr 35 47 0 1 4 51 1801
63
10Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 240 0 5 18 263 13140
64
Pipe Earthing for earthmat as per TS set 5 0 0 0 0 0 0
65
Battery(lead acid, 24 V 100 Ah) Nos 1 132250 0 2645 9919 144814 144814
66
Battery Charger with DCDB Nos 1 78148 0 1563 5861 85572 85572
67
M.S. Structural material for substation MT 1 78000 8034 1721 5850 93605 93605
68
Galvanized fasteneres with all types of Washers MT 0.01 0 0 0 0 0 0
69
G.I pipe 100 mm NB MT 0.25 0 0 0 0 0 0
G
11KV LINE WORKS WITH PCC POLE
70
9 M 300 Kg PCC Poles Nos 68 10219 0 204 766 11190 760907
71
RCC Base Plate Nos 68 0 0 0 0 0 0
72
AAAC Rabbit Conductor (55 sqmm) KM 12.42 34071 0 681 2555 37308 463362
73
Preformed Insulator Binding Nos 183 0 0 0 0 0 0
74
MS galvanized Material for line MT 1.9 57709 0 1154 4328 63191 120064
75
Pipe Earthing as Per TS Nos 7 0 0 0 0 0 0
76
11kV,400A, 3Ph AB Switch set 1 6612 0 132 496 7240 7240
77
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 38 1803 0 36 135 1974 75023
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
78
Danger plate/number plate set 61 78 0 2 6 85 5210
79
Earthing of pole complete with spike earthing,
earth wire as per TS
set 54 10219 0 204 766 11190 604249
80
11KV disc insulator complete with galvanized
insulator fittings, ball and socket type and
complete with galvanized strain, clamp bolts
nuts and washer
set 36 703 0 14 53 770 27712
81
11KV pin insulators, complete with G.I. Pin,
nuts, bolts and washer
Nos 183 343 0 7 26 376 68732
82
Mid span joints & PG Clamp Nos 20 493 0 10 37 540 10797
83
Nuts & Bolts MT 0.1 54102 0 1082 4058 59242 5924
84
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx95 sq. mm Cable
Mtr 100 546 0 11 41 598 59787
85
11kV Cable terminations 0 0 0 0 0
a)
Indoor Nos 2 4509 0 90 338 4937 9875
b)
Outdoor Nos 2 2758 0 55 207 3020 6040
H
LT PACKAGED SUBSTATION set 1 1418679 0 28374 106401 1553454 1553454
i)
Galvanized steel sheet enclosure with steel
base frame for overall Packaged substation.- 1
set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches (400A) and 1 No. circuit breaker
for transformer feeder (400A) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No.
iv)
Low voltage bus bar system 1 set.
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker (Fixed
type 3 pole with fully isolable neutral link)
1 No, Incomer 800 A, MCCB (with necessary
mechanical interlocks between the Incomer
breaker and breaker for emergency use)
2 Nos. 400A TPN MCCB
2 Nos. 200A TPN MCCB +1 No MCCB( suitable
for switching of 100 KVAR Capacitor Bank)
2 Nos.100 A TPN MCCB
vi)
415 V, 100 KVAR Capacitor Banks with 4
step(minimum) APFC relay
vii)
415V Metering (0.5 class)
viii)
HT cable treminations
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
I
415 V LT Feeder Panel consisting of MCCBs etc
and suitable for outdoor type installation
consisting of
set 4 54102 0 1082 4058 59242 236967
1 No, Incomer MCCB 400 A,
2 Nos. 200A MCCB , O/G
2 Nos. 100A MCCB , O/G
4 Nos. 63A MCCB , O/G
J
3.5 C x 240 sqmm LT Power cable Mtr 400 6033 0 121 452 6606 2642454
TOTAL 9436780 207339 192882 707759 10544760 96663532
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
SCHEDULE OF QUANTITY AND PRICES ( BOUGHTOUT ITEMS) (SCHEDULE - 2B)
Name of Bidder LUCKY INDIA POWER SOLUTIONS, GHAZIABAD
Sr.
No
DESCRIPTION Unit Qty UNIT EX
WORKS
PRICE
(Rs.)
ED
@10.30%
CST
@2%
Unit Frt
Charges
(Rs.)
Unit
Total
Prices
(Rs.)
Total
FOR
Prices
(Rs.)
A 33/11 KV DARLIPALI SUB STATION
1
36 kV, Off Load Isolator along with Earth switch,
100A, 12.5 kA rms
set 2 33303 0 666 2498 36467 72934
2
30 kV Lightning arrestor Nos 6 4809 0 96 361 5266 31595
3
2 pole (11mtr Joist/Steel Tubular Pole SP 56)
structure for mounting of 33kv isolator, earth
switch etc
set 2 17974 0 359 1348 19682 39363
4
33 KV Ring Mains Unit (RMU) as per Single line
diagram, each comprising of
set 3 235645 0 4713 17673 258031 774094
i)
1 No. 33KV Ring Main unit, Non-extensible,
Manually operated, consisting of 2 No. Load
break switches (100 Amps) and 1 No. circuit
breaker (400 Amps) for transformer feeder
along with earth switches each for load break
switch and circuit breaker
ii)
33KV Metering (0.2s accuracy class)
iii)
HT Cable Terminations and
iv)
Internal cabling for connections between the
equipments of RMU, lighting & earthing system
along with required hardware, gaskets, gland
plates etc as required
5
3.15 MVA, 33/11kV, Power Transformer, ONAN
with neutral CT
Nos 3 1853000 190859 40877 138975 2223711 6671134
6
11 KV Ring Mains Unit (RMU) as per Single line
diagram, each comprising of
set 3 420795 0 8416 31560 460771 1382312
i)
Galvanized Steel sheet enclosure of 1.6mm
minimum thickness with steel base frame for
RMU
ii)
11KV Ring Main unit, Non-extensible, Manually
operated, consisting of 2 Nos. Load break
switches (400 Amps) and 2 Nos. circuit breakers
(400Amps) for transformer feeder along with
earth switches
iii)
HT Cable Terminations and
iv)
Internal cabling for connections between the
equipments of RMU, lighting & earthing system
along with required hardware, gaskets, gland
plates etc as required
7
19/33 kV grade, XLPE, A1 conductor PVC
sheathed, armoured 1Cx150 sq. mm Cable
Mtr 500 432 0 9 32 473 236520
8
6.35/11 kV grade, XLPE, A1 conductor PVC
sheathed, armoured 1Cx300 sq. mm Cable
Mtr 800 417 0 8 31 457 365292
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
9
33kV Cable terminations
a)
Indoor Nos 27 5094 0 102 382 5578 150604
b)
Outdoor Nos 18 3411 0 68 256 3735 67231
10
11kV Cable terminations 0
a)
Indoor Nos 27 4509 0 90 338 4937 133309
b)
Outdoor Nos 45 2758 0 55 207 3020 135900
11
11kV, 200 KVAR Capacitor banks suitable for
outdoor installation and complete in all respects
including fuse, mounting racks
set 2 90170 0 1803 6763 98736 197472
12
33/11KV substation Misc. items like conductor,
hardware, insulators, clamp connectors etc
Lot 1 300568 0 6011 22543 329122 329122
13
Earthing (earthmat)as per TS set 1 153741 0 3075 11531 168346 168346
14
Fire Fighting System CO2 type/CTC type/dry
type as per TS
Lot 1 18635 0 373 1398 20405 20405
15
Testing Instruments as per TS Lot 1 0 0 0 0 0 0
16
S/s Chain Link Fencing and Gate as per TS Nos 1 0 0 0 0 0 0
17
Lighting Mast (30 meter) as per TS Nos 16 5230 0 105 392 5727 91630
18
LT AB Cable 4Cx16sqmm, Aluminium conductor
with armour for Lighting Mast
Mtr 1000 9131 0 183 685 9998 9998445
19
33 kv Metering cublicle with 0.2s accuracy class
meter with matching CT PT (Indoor type) as per
TS
Nos 2 60000 6180 1324 4500 72004 144007
B
PACKAGED SUB STATIONS
20
11 kV Lightning arrestor Nos 57 2164 0 43 162 2370 135066
21
11 kV, 3, 50 A On load Isolator Nos 19 22242 0 445 1668 24355 462745
22
2 pole (11mtr Joist/Steel Tubular Pole SP 56)
structure for mounting of 11kv isolators etc
set 19 17974 0 359 1348 19682 373949
23
LT Packaged Substation each comprising of set 6 1538906 0 30778 115418 1685102 10110612
i)
Galvanized steel sheet enclosure with steel base
frame for overall Packaged substation.- 1 set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches (400A) and 1 No. circuit breaker
for transformer feeder (400A) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No.
iv)
Low voltage bus bar system 1 set.
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker (Fixed
type 3 pole with fully isolable neutral link)
1 No, Incomer 800 A, MCCB (with necessary
mechanical interlocks between the Incomer
breaker and breaker for emergency use)
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
2 Nos. 400A TPN MCCB
2 Nos. 200A TPN MCCB +1 No MCCB( suitable
for switching of 100 KVAR Capacitor Bank)
2 Nos.100 A TPN MCCB
vi)
415 V, 100 KVAR Capacitor Banks with 4
step(minimum) APFC relay
vii)
415V Metering (0.5 class)
viii)
HT cable treminations
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
24
LT Packaged Substation set 13 1262384 0 25248 94679 1382310 17970036
LT Packaged Substation each comprising of
i)
Galvanized steel sheet enclosure with steel base
frame for overall Packaged substation.- 1 set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches(400 A) and 1 No. circuit breaker
for transformer feeder (400) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No
iv)
Low voltage bus bar system 1 set
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker ,20 KA
for 1 sec
2 Nos. 400A TPN MCCB ,20 KA
2 Nos. 200A TPN MCCB ,20 KA
2 Nos.100 A TPN MCCB ,20 KA
1 No. MCCB suitable for switching of 20 KVAR
Capacitor Bank
vi)
415 V, 20 KVAR Capacitor Bank without APFC
vii)
415V Metering (Class 0.5)
viii)
HT cable terminations
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
25
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx95 sq. mm Cable
Mtr 1000 546 0 11 41 598 597870
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
26
11 kV, 300A poles mounted Isolator (3 phase)
OFF LOAD
Nos 7 22242 0 445 1668 24355 170485
27
11 kV Lightning arrestor Nos 9 2164 0 43 162 2370 21326
28
11KV DO fuse, 160 A set 1 6011 0 120 451 6582 6582
C
33 KV line
29
ACSR DOG 100 sq mm ( 7/4.26) conductor as
per TS
KM 131 70850 0 1417 5314 77581 10163078
30
11mtr. Joist Pole with pin and strain insulators,
earthing arrangement , material for concrete
foundation, danger plate,preformed insulator
bindings, performed jointing sleeves , fasteners
& washers, and required hardware, complete (
as per TS)
a)
11mtr. MS Joist MT 209 17974 0 359 1348 19682 4113440
b)
GI Material MT 14 57709 0 1154 4328 63191 884679
c)
Nuts and Bolts MT 3 54102 0 1082 4058 59242 177725
d)
11 KV Disc Insulator 70 KN Nos 4608 283 0 6 21 310 1427950
e)
Disc Insulator Hardware fittings Nos 4608 421 0 8 32 461 2124265
f)
Helical fitting for 11 KV Disc Insulator Nos 4608 469 0 9 35 514 2366461
g)
33 KV PIN Insulator Nos 120 228 0 5 17 250 29959
h)
GI Pin for Pin Insulator Nos 120 234 0 5 18 256 30748
i)
Pipe Earthing 32NB Medium class as per IS
1161,2500mm GI Pipe
Nos 512 0 0 0 0 0 0
j)
PG Clamps/Jointing sleeve Nos 240 132 0 3 10 145 34690
k)
Danger Board Nos 472 78 0 2 6 85 40314
l)
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 472 1850 0 37 139 2026 956154
D
HT CABLE
31
19/33 KV grade XLPE,Al conductor PVC
sheathed,armoured Cable 3Cx240 sqmm
KM 3.5 1666 0 33 125 1824 6385
32
Cable Termination and Jointing Kits Outdoor Nos 18 5094 0 102 382 5578 100403
33
Cable Termination and Jointing Kits Indoor Nos 2 3411 0 68 256 3735 7470
34
HDPE Pipe 150mm Mtr 500 0 0 0 0 0 0
E
11 KV OVER HEAD LINES WITH STEEL TUBULAR
POLE
35
11 meter steel Tubular pole type designation:
410-SP-56
a)
Four poles.(sets) Nos 34 118772 0 2375 8908 130055 4421882
b)
Double pole.(sets) Nos 6 51247 0 1025 3844 56115 336693
c)
Single pole.(sets) Nos 70 29005 0 580 2175 31760 2223233
36
M.S. Angle, channel flat. GI nuts and bolts etc.
for cross arms, cross bracing clamps, pole top
bracket etc
a)
Four poles.(sets) Nos 34 54102 0 1082 4058 59242 2014217
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
b)
Double pole.(sets) Nos 6 37270 0 745 2795 40811 244864
c)
Single pole.(sets) Nos 70 19236 0 385 1443 21063 1474439
37
Protective guard wire complete with galvanized
steel wire. Cross arm channel for road crossing
set 5 0 0 0 0 0 0
38
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 218 1803 0 36 135 1974 430394
39
Danger plate/number plate set 110 78 0 2 6 85 9395
40
Earthing of pole complete with spike earthing,
earth wire, salt and charcoal coke as per TS
set 218 10219 0 204 766 11190 2439377
41
11KV disc insulator complete with galvanized
insulator fittings, ball and socket type and
complete with galvanized strain, clamp bolts
nuts and washer
set 297 703 0 14 53 770 228626
42
11KV pin insulators, complete with G.I. Pin,
nuts, bolts and washer
Nos 489 343 0 7 26 376 183661
43
ACSR Racoon conductor KM 23 54391 0 1088 4079 59558 1369837
44
Mid span joints & PG Clamp Nos 50 493 0 10 37 540 26992
45
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx240 sq. mm Cable with
Screen fault current of 3 kA
KM 2 981 0 20 74 1074 2148
46
11 kV Cable terminations kit, 3 phase, Outdoor
type
Nos 10 2758 0 55 207 3020 30200
F
11KV BAY WORKS
47
11 KV, 3Ph VCB, 800 A with structure Nos 1 240454 0 4809 18034 263297 263297
48
11 KV, 3Ph isolator, 800 A Nos 2 22242 0 445 1668 24355 48710
49
Single Phase 11 KV Current Transformer Nos 3 11500 1185 254 863 13801 41402
50
Single Phase 11KV Potential Transformer Nos 3 10500 1082 232 788 12601 37802
51
Indoor Control & Relay Panel for 11KV feeder
with Energy Meter as per TS
Nos 1 180341 0 3607 13526 197473 197473
52
ACSR DOG 100 sq mm ( 7/4.26) conductor as
per TS
KM 0.05 70850 0 1417 5314 77581 3879
53
11kV,400A, 3Ph AB Switch for Outgoing DP set 1 6973 0 139 523 7635 7635
54
11 kV Lightning arrestor Nos 3 2164 0 43 162 2370 7109
55
Junction Box for CT (1 JB common for 3 phases)
for bay augmentation as per TS
Nos 1 4500 0 90 338 4928 4928
56
Junction Box for PT (1 JB common for 3 phases)
for bay augmentation as per TS
Nos 1 4500 0 90 338 4928 4928
57
Insulator, Hardware fittings, Clamps,
Connectors, Lugs, Ferrules for bay
augmentation works in substations as per TS
LS 1 240454 0 4809 18034 263297 263297
58
3Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 75 95 0 2 7 104 7802
59
5Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 141 0 3 11 154 7720
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
60
7Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 185 0 4 14 203 10129
61
4Cx10 sqmm PVC, armoured Aluminium power
cable
Mtr 40 60 0 1 5 66 2628
62
4Cx6 sqmm PVC, armoured Aluminium power
cable
Mtr 35 47 0 1 4 51 1801
63
10Cx2.5 sqmm PVC, armoured copper control
cable
Mtr 50 240 0 5 18 263 13140
64
Pipe Earthing for earthmat as per TS set 5 0 0 0 0 0 0
65
Battery(lead acid, 24 V 100 Ah) Nos 1 132250 0 2645 9919 144814 144814
66
Battery Charger with DCDB Nos 1 78148 0 1563 5861 85572 85572
67
M.S. Structural material for substation MT 1 78000 8034 1721 5850 93605 93605
68
Galvanized fasteneres with all types of Washers MT 0.01 0 0 0 0 0 0
69
G.I pipe 100 mm NB MT 0.25 0 0 0 0 0 0
G
11KV LINE WORKS WITH PCC POLE
70
9 M 300 Kg PCC Poles Nos 68 10219 0 204 766 11190 760907
71
RCC Base Plate Nos 68 0 0 0 0 0 0
72
AAAC Rabbit Conductor (55 sqmm) KM 12.42 34071 0 681 2555 37308 463362
73
Preformed Insulator Binding Nos 183 0 0 0 0 0 0
74
MS galvanized Material for line MT 1.9 57709 0 1154 4328 63191 120064
75
Pipe Earthing as Per TS Nos 7 0 0 0 0 0 0
76
11kV,400A, 3Ph AB Switch set 1 6612 0 132 496 7240 7240
77
Guy sets complete with galvanized stranded
steel guy wire, stay rod, guy strain insulators,
guy anchor, guy anchor plate, turn buckle
thimble etc
set 38 1803 0 36 135 1974 75023
78
Danger plate/number plate set 61 78 0 2 6 85 5210
79
Earthing of pole complete with spike earthing,
earth wire as per TS
set 54 10219 0 204 766 11190 604249
80
11KV disc insulator complete with galvanized
insulator fittings, ball and socket type and
complete with galvanized strain, clamp bolts
nuts and washer
set 36 703 0 14 53 770 27712
81
11KV pin insulators, complete with G.I. Pin,
nuts, bolts and washer
Nos 183 343 0 7 26 376 68732
82
Mid span joints & PG Clamp Nos 20 493 0 10 37 540 10797
83
Nuts & Bolts MT 0.1 54102 0 1082 4058 59242 5924
84
11/6.35 kV grade, XLPE, A1 conductor, PVC
sheathed, armoured 3Cx95 sq. mm Cable
Mtr 100 546 0 11 41 598 59787
85
11kV Cable terminations 0 0 0 0 0
a)
Indoor Nos 2 4509 0 90 338 4937 9875
b)
Outdoor Nos 2 2758 0 55 207 3020 6040
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
H
LT PACKAGED SUBSTATION set 1 1418679 0 28374 106401 1553454 1553454
i)
Galvanized steel sheet enclosure with steel
base frame for overall Packaged substation.- 1
set
ii)
1 No. 11KV Ring Main unit, Non-extensible,
manually operated, consisting of 1 No. Load
break switches (400A) and 1 No. circuit breaker
for transformer feeder (400A) along with earth
switch for load break switch and circuit breaker
iii)
11KV/0.433 V, Dyn11 oil type sealed
transformer 500 kVA, 11/0.433 kV ONAN
Transformer with all accessories- 1 No.
iv)
Low voltage bus bar system 1 set.
v)
415 V LT distribution board consisting of Air
circuit breaker (ACB), MCCBs etc and suitable
for outdoor type installation consisting of
1 No, Incomer 800 A, Air circuit breaker (Fixed
type 3 pole with fully isolable neutral link)
1 No, Incomer 800 A, MCCB (with necessary
mechanical interlocks between the Incomer
breaker and breaker for emergency use)
2 Nos. 400A TPN MCCB
2 Nos. 200A TPN MCCB +1 No MCCB( suitable
for switching of 100 KVAR Capacitor Bank)
2 Nos.100 A TPN MCCB
vi)
415 V, 100 KVAR Capacitor Banks with 4
step(minimum) APFC relay
vii)
415V Metering (0.5 class)
viii)
HT cable treminations
ix)
Internal cabling for connections between the
equipments of packaged substation, lighting &
earthing (as per TS) system along with required
hardware, gaskets, gland plates etc as required
for packaged substation
I
415 V LT Feeder Panel consisting of MCCBs etc
and suitable for outdoor type installation
consisting of
set 4 54102 0 1082 4058 59242 236967
1 No, Incomer MCCB 400 A,
2 Nos. 200A MCCB , O/G
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
2 Nos. 100A MCCB , O/G
4 Nos. 63A MCCB , O/G
J
3.5 C x 240 sqmm LT Power cable Mtr 400 6033 0 121 452 6606 2642454
K
11KV metering cubicle with 0.5 accuracy class
meter with matching CT PT
Nos 1 93777 0 1876 7033 102686 102686
TOTAL 9530557 207339 194758 714792 10647446 96766218
YOU WILL BE GLAD TO KNOW THAT WE HAVE STARTED OUR OWN MANUFACTURING OF ALL TYPES OF CTs/PTs/CTPT
UNITS/METERING CUBICLES/LTCT/RVT RESIN CAST / OIL COOLED, INDOOR / OUTDOOR, DEAD TANK / LIVE TANK UPTO THE
SYSTEM VOLTAGE OF 33KV CLASS BY THE NAME OF MINI ENGINEERING WORKS AT GHAZIABAD AND ABOVE 33KV TO
400KV CLASS WE BECAME CHANNEL PARTNER OF MEHRU ELECTRICAL & MECHANICAL ENGINEERS PVT. LTD, BHIWADI.
APART FROM MANUFACTURING OF CTs/PTs, WE ALSO STARTED MANUFACTURING OF ALL TYPES OF DISTRIBUTION BOXES,
TRANSFORMER PROTECTION BOXES, METER BOXES, ALL TYPES OF ENCLOSURES. WE ARE ALSO ENGAGED IN ALL TYPES
OF HEAVY FABRICATION AS PER CUSTOMER REQUIREMENT(S) AS PER THEIR DRAWING.
KINDLY NOTE THAT WE ARE ALSO A LEADING SUPPLIER BY THE NAME LUCKY INDIA POWER SOLUTIONS AND CAN
SUPPLY YOU SUBSTATION COMPLETE MATERIALS UPTO 400KV INCLUDING COMPLETE SUBSTATION / PLANT AUTOMATION
SYSTEM BY SCADA, PLC. YOU ARE, THEREFORE, REQUESTED TO KINDLY SEND US COMPLETE BOQ SO TO SEND YOU OUR
BEST & COMPETITIVE OFFER ALONGWITH BEST QUALITY MATERIALS TOO.
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
COMMERCIAL TERMS
1. PRICES: Prices quoted are net ex our works at Di f f e r e n t L o c a t i o n s .
2. EXCISE DUTY: NIL
3. PRICE VARIATION CLAUSE: The prices quoted by us are variable as per standard IEEMA FORMULA without any ceiling. The
base date will be as on 01/03/2014.
3. SALES TAX: Shall be charged extra @ 2% against form C.
4. DELIVERY: The delivery schedule shall be as per your delivery schedule.
5. PAYMENTS: 25% advance alongwith technically & commercially clear Purchase Order and balance 75% against Proforma
Invoice after successful Inspection before dispatch.
6. VALIDITY: Offer is valid for a period of 30 days from the date of offer.
7. PRICE ESCALATIONS: The prices have been quoted after taking into account prevailing discounted rates of the items suppliers
mentioned in Bill of Material as on the date of this offer. Any subsequent increase in the rates of these items on account of
price revisions or increase in taxes / duties / levies shall be charged extra to your account.
8. WARRANTEE: Our products are guaranteed for a period of 12 months from the date of commissioning or 18 months from the
date of supply whichever is earlier against any manufacturing defects.
9. INSPECTION & TESTING: Final testing of items shall be carried out at our Principals works.
10. Form C or any other applicable form shall be submitted at the time of taking delivery. If the form is not submitted then
difference of Tax amount shall be kept as a deposit until we receive the Form.
11. FREIGHT: Freight shall be charged extra as per actuals.
12. PACKING: The Packing charges shall be extra @ 4%.
Hope you will find our offer in order and will favour us with your valued order.
Thanking you,
Yours faithfully,
FOR Lucky India Power Solutions
SHARAFAT ALI
Managing Director
Mob: +919868667484 / +919759381998
emails: info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com / mew.ctpt@gmail.com /
ctptmfgrs@outlook.com
website: http://www.luckyindiapowersolution.com
http://www.ctpttransformer.com
http://www.indiamart.com/luckyindiapowersolutions/
linkedin: in.linkedin.com/in/luckyindiapowersolutions
http://ctptvcbpanels.bloombiz.com
skype: luckyindiatrafopanels

Vous aimerez peut-être aussi