The document describes various electrical auxiliaries that can be combined with Merlin Gerin C60, C120, DPN Vigi, and ID circuit breakers to provide remote tripping or indication. The auxiliaries include auxiliary contacts, fault indicating switches, changeover contacts, undervoltage releases, shunt releases, and releases for push buttons and voltage thresholds. The auxiliaries range in width from 2 to 4 modules of 9mm and provide functions such as indicating open or closed positions, tripped faults, selecting indication functions, undervoltage control, and emergency stops.
The document describes various electrical auxiliaries that can be combined with Merlin Gerin C60, C120, DPN Vigi, and ID circuit breakers to provide remote tripping or indication. The auxiliaries include auxiliary contacts, fault indicating switches, changeover contacts, undervoltage releases, shunt releases, and releases for push buttons and voltage thresholds. The auxiliaries range in width from 2 to 4 modules of 9mm and provide functions such as indicating open or closed positions, tripped faults, selecting indication functions, undervoltage control, and emergency stops.
The document describes various electrical auxiliaries that can be combined with Merlin Gerin C60, C120, DPN Vigi, and ID circuit breakers to provide remote tripping or indication. The auxiliaries include auxiliary contacts, fault indicating switches, changeover contacts, undervoltage releases, shunt releases, and releases for push buttons and voltage thresholds. The auxiliaries range in width from 2 to 4 modules of 9mm and provide functions such as indicating open or closed positions, tripped faults, selecting indication functions, undervoltage control, and emergency stops.
Multi 9 Merlin Gerin Combined with the Merlin Gerin C60, C120 circuit-breakers, ID residual current and DPN Vigi circuit-breakers They ensure remote tripping or indication. Auxiliary contacts: OF and OF.S Indication of the open or closed position of the circuit--breaker (OF) or the residual current circuit-breaker (OF.S)with which they are combined. Fault indicating switch: SD Indication of the fault trip position of the circuit--breaker or residual current circuit-breaker with which it is combined. Visualisation of the fault (circuit- breaker)or earth fault indication (ID) on the front face by means of a mechanical indicator. Changeover contact: OF + SD/OF I Upper circuit:OF,lower circuit:OF or SD. I OF:remote indication of the open or closed position of the circuit-breaker or residual current circuit-breaker with which it is associated. I SD:remote indication of the tripped on fault position of the circuit-- breaker or residual current circuit-breaker with which it is associated. I Function choice using the selector switch on the right side. I The selected function is indicated on the front face. Undervoltage selective release: MN s Undervoltage release that controls the opening of the circuit-breaker or residual current circuit-breaker with which it is combined;it allows a 0.5 second time delay on a brownout or voltage drop. Undervoltage instant release: MN When its supply voltage drops (between 70 and 35 %),it controls the tripping and opening of the circuit-breaker or residual current circuit-breaker with which it is combined.Furthermore,it prevents the circuit-breaker or the residual current circuit-breaker from reclosing as long as its supply voltage is not restored. I Utilisation: - emergency stop using a pushbutton, - safety on the circuits supplying several machines by preventing uncontrolled restart of all motors.. Shunt release: MX + OF When energised,it controls the tripping and opening of the circuit-breaker or residual current circuit-breaker with which it is combined. Aquipped with an O +C contact to indicate the open or closed position of the circuit-breaker or the residual current circuit-breaker. Release for push button: MNx Completely unaffected by power supply circuit cuts,it is recommended for fail-safe emergency stops.Replaces the voluntary MX release equipped with its NO/NC indicator lights. Relaese with voltage threshold: MSU Specially designed to monitor voltage between the neutral and phase(s) conductors,it cuts off the power supply by opening the circuit-breaker in event of overvoltage (case of neutral breaking). The rang The range e + MERLIN GERIN multi 9 DPN vigi C40 I n 0,300A 230Va 20912 BS EN 61009 O - OFF test mensuel test monthly N 2 N 1 a 4500 6 kA IEC 947.2 + + + + + MERLIN GERIN multi 9 MX OF 220.415Va 26946 110.130V MERLIN GERIN multi 9 MN 220.415Va 26960 U < D1 D2 MERLIN GERIN multi 9 C60N C25 400Va 6000 24204 O - OFF O - OFF 10kA IEC 947.2 1 3 2 4 MERLIN GERIN multi 9 ID 23185 a T N 2 N 1 80A I n 0,300A 240Va OFF S 12 CEBEC 26927 reset SD 94 91 92 92 94 91 9 mm SD - OF 11 12 14 9 mm 21 95 22 98 24 96 9 mm 26924 14 12 11 9 mm 12 11 14 e OF T ts MERLIN GERIN multi 9 C120N C63 415Va 10000 18360 3 O - OFF O - OFF 2 4 1 3 SD OF+SD/ OF MX + OF or MSU MN, MN s ss ss or MNx Auxiliaries DPN Vigi C60 C120 ID OF or OF.S 26923 OF.S C60 RCBO Get more with the worlds Power & Control specialist OF MN MNx MSU MX+OF SD MN s OF+SD/OF WIRING SCHEMES WIRING SCHEMES IMPLEMENT IMPLEMENTA ATION TION I Designed for installation in modular electrical enclosures and cubicles. I Easy connection and reliability ensured by the serrated tunnel terminals with guard. I Captive screws with mixed imprint. I Simplified combination with C60,C120,DPN Vigi circuit- breakers and ID residual current circuit-breakers using clip-ons. The electrical auxiliaries allow remote tripping or indication of the circuit-breakers with or without Vigi module.They are mounted on the left-hand side of the circuit-breaker (max.width:54 mm).Use of the OF.S auxiliary contact is compulsory for adding the MN,MX, SD, OF ,MNx,MSU functions to the ID residual current circuit breaker switch. Operation simulation I On the front face of the auxiliary contacts (26924 26927) ,a test button allows for the OF and SD functions to be simulated without generating the circuit-breaker or the residual current circuit-breaker. TECHNICAL D TECHNICAL DA AT TA A SCHNEIDER ELECTRIC HELP CENTRE Tel: 1300 369 233 Fax: 1300 369 288 Email: help@schneider.com.au www.schneider-electric.com.au AUS01PL06-A type voltage (V) width in Cat mod. 9mm no. auxiliary contacts OF 1 26924 OF.S 1 26923 fault indicating switch SD 1 26927 changeover contact OF + SD/OF 1 26929 undervoltage release MN 220 to 240 V AC 2 26960 48 V AC 2 26961 48 V DC 2 26962 MN s 220 to 240 V AC 4 26963 0.2 sec delay release for PB push button with opening MNx 230 V AC 4 26969 400 V AC 4 26971 shunt release MX + OF 220 to 415 V AC 2 26946 110 to 130 V DC 48 to 130 V AC 2 26947 48 V DC 24 V AC -DC 2 26948 12 V AC -DC 2 26949 voltage increae release MSU 230 V AC 4 26979 400 V AC 4 26980 Release consumption type voltage (V) (W or VA) MX 415 V AC 120 220 to 240 V AC 50 110 to 130 V AC 200 110 to 130 V DC 10 48 V AC -DC 22 24 V AC -DC 120 12 V AC -DC 120 MN 220 to 240 V AC 4.1 48 V AC 4.3 48 V DC 2.0 MN s 220 to 240 V AC 4.1 MNx 230 V AC 50 400 V AC 120 MSU 230 V AC 1Ph +N 50 400 V AC 3Ph +N 120 Contact auxiliary breaking capacity voltage (V) (A) 415 V AC 3 240 V AC 6 130 V DC 1 24 V DC 6 14 12 11 21 91 22 94 24 92 OF + SD/OF MNx E2 N E1 L U < SD 91 92 94 OF-OF.S D2 D1 U < MN - MN s ss ss MX + OF C1 C2 12 14 U > E2 L1 E1 L2 U < MNx 11 12 14 L3 L2 N L1 U >> 3Ph + N MSU 1Ph + N MSU N L U >>