Vous êtes sur la page 1sur 3

NRL VIDEO CABLE ARMOURED

J OB Card No: 1



Sr.No.

Description Specification Remark
Item
RG-11/A Co-axial Video Cable
65 % Pure Copper Braiding
RG-11/A Armored co-axial video
cable 65% pure bare copper
braiding. Armored FRLS

Order Qty 5050 Meters
1 Conductor Solid Copper Conductor
2 Insulation Foam PE
3 Insulation Thickness As per RG 11 Standard
4 Colour Code Natural
5 OD After Core Insulation As per Standard of RG-11/A
6 Braiding Bare Copper
7 Coverage 65 % Pure Copper
8 Size of Copper Wire As per Standard of RG-11/A
9 Outer J acket PVC FRLS
10 Colour Black
11 Thickness As per Standard
12 Packing 1010 Meters x 5 =5050 Mtrs
13 Test on the conductor As per IS- 8130
14 Test on the Insulation As per RG-11/U Test
15 Test on the Braiding As per IS 8180
16 Test on the Outer PVC J acket As per IS 5831
17 Packing In Drum
18 Remark
19 Remark







NRL POWER CABLE
J OB Card No: 2

Sr.No. Description Specification Remark
Item 3 Cores x 1.50 Sq. MM Armoured
Power Cables


Order Qty 5100 Meters
1 Conductor Solid Copper Conductor
2 Insulation PVC Type A
3 Insulation Thickness 0.80 MM As per Standard
4 Colour Code As per IS 1554
5 OD After Core Insulation As per IS 1554 Standard
6 Laid Up All Cores Laid up
7 Inner Sheath PVC 0.50 Mm Radial Thickness
8 Armoring 1.40 MM G.I. Wire Armoured
9 Outer J acket FRLS
10 Colors Black
11 Thickness As per Standard
12 Packing 1020 Meters x 5 =5100 Mtrs
13 Test on the conductor As per IS- 8130
14 Test on the Insulation As per IS- 1554/5831
15 Test on the Armouring As per IS 3975
16 Test on the Inner/ Outer PVC J acket As per IS 5831
17 Packing In Drum
18 Remark
19 Remark


NRL- DATA (TWISTED/SHIELDED) CABLE
J OB Card No: 3

Sr Description Specification Remark
Item 2 Cores x 1.50 Sq. MM Armoured
(Power Cables )
2 core x1.5sq. mm Armored
Twisted shielded (75%) Data
cable
75% Pure bare Copper
Braiding
Order Qty 5100 Meters
1 Conductor Stranded 7/0.53 MM Bare
Copper Conductor

2 Insulation PVC Type A
3 Insulation Thickness 0.80 MM As per Standard
4 Colour Code As per IS 1554
5 OD After Core Insulation As per IS 1554 Standard
6 Twisting 12 to 14 Twist Per Mtrs
6A Mylar Tapped
100 % Coverage & 35 % Overlapp
6B Aluminum Mylar Tapped Shield
100 % Coverage & 35 % Overlapp
6C Copper Braiding
75 % Coverage Bare Copper Braiding
6D Drain Wire In Contact With Foil Side 7/0.30 MM ATC Copper Drain Wire

6E Mylar Tapped
100 % Coverage & 35 % Overlapp
7 Inner Sheath PVC 0.80 Mm Radial Thickness
8 Armoring 1.40 MM G.I. Wire armored
9 Outer J acket PVC FRLS
10 Colour Black
11 Thickness As per Standard
12 Packing 1020 Meters x 5 =5100 Mtrs
13 Test on the conductor As per IS- 8130
14 Test on the Insulation As per IS- 1554/5831
15 Test on the Armouring As per IS 3975
16 Test on the Inner/ Outer PVC J acket As per IS 5831
17 Cables Standard As per BS- 5308 Standard
18 Packing In Drum
19 Remark
20 Remark

Vous aimerez peut-être aussi