Vous êtes sur la page 1sur 7

Mr.Bamboo,Inc.

BamStrand
PrefinishedStrandWovenBambooFlooring
CSIMasterformat3PartSpecification

Part1General

1.1 SUMMARY

A. ThissectionIncludes:Prefinished,{prestained}solidStrandWovenbamboostripflooringinstalledbythe
{naildownmethod.},{gluedownmethod.}or{nailandgluedownmethod}asselectedbycontractor.
B. OtherRelatedsections
Listotherspecificationsectionsdealingwithworkdirectlyrelatedtothissectionandforothertypesofflooring
materialsborderingthebambooflooringandanyfinishedtrim.
1. 00115GreenBuildingRequirements:LEEDSrequirements.
2. 03300Concreteslab.
3. 06100RoughCarpentry:Woodsubfloor.
4. ________________________________________________________________________________.

1.2 SUBMITTALS

A. SubmitunderprovisionsSection01330SubmittalProceduresthefollowingitems:
Mr.Bamboo,Inc.BamStrandstrandwovenprefinishedsolidbambooflooring
1. ProductData
a. Flooring:
Includeselectedcolor
Adhesiveusedinmanufactureofflooring
Finishdata:type,compositionandmanufacturer
b. Accessories
c. Installationguidelines
d. Warranty
2. ShopDrawing:Includedirectionofflooring,fasteningmethod,flooringpatternsandcolorlayout.Also
includelargescalesectionaldetailsofaccessoriesandtransitionstootherflooring.
3. Samples:
a. 6(150mm)longstripofprefinishedbambooflooringmaterialinstockorcustomcolormatch
color.
b. Fasteners/Nails.
c. Oneofeachspecifiedaccessory,minimum6(150mm)long.
4. QualityAssurance/ControlSubmittals:
a. Qualification:Proofofmanufacturerandinstallerqualifications.
b. TestReports:ReportsforspecifiedPhysicalPropertyPerformanceRequirements.
c. ManufacturersInstallationInstructions.

B. CloseoutSubmittals:ReferencetoSection01780CloseoutSubmittalsthefollowingitems:
1. MaintenanceInstructions
2. Warranty

C. LEEDSubmittals:
1. CreditEQ4.1:Woodflooringadhesivemanufacturersproductdataindicatingthattheadhesiveusedhasa
VOCoflessthan100g/Llesswater.
2. CreditWQ4.2:WoodflooringcoatingdataindicatingfinishusedhasaVOCoflessthan100g/L.
3. CreditMR6:Rapidlyrenewablematerial.

09640Page2
Mr.Bamboo,Inc.
PrefinishedBambooFlooring
CSIMasterformant3PartSpecification

1.3 QUALITYASSURANCE

1. ManufacturerQualifications:
a. Minimumtenyearsexperienceinthemanufactureanddistributionofbambooflooring.
b. MemberofUSGreenBuildingCouncil,NationalWoodFlooringAssociation

2. InstallerQualifications:
a. Minimumofthreeyearsexperienceinhardwoodand/orbambooflooringinstallation.
b. Minimumthreeyearsexperienceininstallationofhardwoodand/orbambooflooringoverradiant
heatingsystems.

1.4 DELIVERY,STORAGE,ANDHANDLING

A. ReferenceSection01660ProductStorageHandingRequirements.
B. DeliverBambooflooringtoprojectsiteinoriginalpackagingnotlessthan5dayspriortoinstallationstart
datetoallowfloortoacclimatetositeconditions.

1.5 PROJECTORSITECONDITIONS

NOTEFORRADIANTHEAT:Foraradiantfloorheatingsystemspecify5daysintheparagraphbelow.

EnvironmentalRequirements:Allinstallationandreceivingareasofbambooflooringandadhesivemustbe
maintainedatnormaloccupancytemperatureandhumiditylevelsforminimum5dayspriorto,during,
andcontinuouslyfollowinginstallation.ItisimportanttheHVACsystembeoperatingandcontrollingtemperature
andhumiditylevels.Maintainhumiditylevelbetween40and60percent.

1.6 WARRANTY
FORCOMMERCIALPROJECTS,USEWARRANTYARTICLESA.ANDB.
FORRESIDENTIALPROJECTS,USEWARRANTYARTICLESA.ANDC.

A. Mr.BambooBamStrand30YearStructuralWarrantyagainstdelaminating,separation,bucklingor
cuppingasaresultofamanufacturingdefectwheninstalledandmaintainedinaccordancewith
manufacturersinstallationinstructions.

B. Mr.BambooBamStrand10YearsFinishWarrantyagainstwearthroughtotheunderlyingbamboo
flooringorseparationfromtheflooringwheninstalledandmaintainedinaccordancewithmanufacturers
installationandmaintenanceinstructionsincommercialinstallations.

C. Mr.BambooBamStrand25YearFinishWarrantyagainstwearthroughtotheunderlyingbamboo
flooringorseparationfromtheflooringwheninstalledandmaintainedinaccordancewithmanufacturers
installationandmaintenanceinstructionsinresidentialinstallations.

09640Page3
Mr.Bamboo,Inc.
PrefinishedBambooFlooring
CSIMasterformant3PartSpecification

PART2PRODUCTS

2.1 MANUFACTURERINFORMATION

A. Mr.Bamboo,Inc. TollFree(888)6722628
712CountyLineRd Tel: (630)2276600
Bensenville,IL60106 Fax:(630)2276601
Website:www.mrbambooflooring.com emailinfo@mrbambooflooring.com

Insertname,addressandphonenumbersoflocaldistributor/dealerbelow.
1.Distributor/Dealer ________________________________________________
________________________________________________
________________________________________________

B. BamStrandBambooFlooring
1.Color:CoffeeorNatural
2.Thickness:9/16or14mm
3.Joint:Tongueandgroovejointwith1/4
4.Edge:Smallbevelonedgeandends

C. Substitutions:NonePermitted

2.2 MATERIALS

A. BambooFlooring
1. Species:Moso
2. Size:33/4(95mm)wideby9/16(14mm)thick72(1830mm)long.
3. Edge:Smallbeveledgedtongueandgroove.
4. Back:Channeledandfactoryfinished.
5. ChemicalTreatment:Naturalboratesolutionandhydrogenperoxidetoeliminatepestsand
mildew
6. Factoryfinish:SixcoatsofKlumppfinishforhightrafficuse.
7. BambooHarvestBambooisharvestedin56years.
8. PhysicalPropertyPerformanceRequirements:
a. Hardness:ASTMD1037,JankaBall:3080forNaturaland2302forCoffee.
b. DimensionalStability:ASTMD1037:Dimensionallengthchange:Natural:0.004%,Coffee:
0.008%.Widthchange:forbothNaturalandCoffeecolortherewasnomeasurable
change.Thicknesschange:forbothNaturalandCoffeecolortherewasnomeasurable
change.
c. Flammability:ASTME648:Class1InteriorFloorFinishratingperNFPA101.
d. SmokeDensity:ASTME622:MaximumNatural239inflamingmode:andCoffee161in
nonflamingmode
e. MoistureContent:ASTMD4442,OvenDryMethod:6%percentaverage.
f. FormaldehydeEmissions:ASTME1333:FormaldehydeemissionwellbelowE1standard
requirements.FormaldehydecontentNaturalat0.002mg/100gandCoffeeat
0.003mg/100g(E1standardis1.5mg).

09640Page4
Mr.Bamboo,Inc.
PrefinishedBambooFlooring
CSIMasterformat3PartSpecification

B. InstallationAdhesive:Onepartmoisturecuredurethanepremiumwoodflooradhesive.

C. Fasteners:
1. 11/2(38mm)ThickSubfloor:2(50mm)nails.
2. 3/4(19mm)ThickSubfloor:11/2(38mm)nails.
3. 1(25mm)ThickPlywoodSubflooroverConcrete:11/4(32mm)nails.

D. Subfloors
1. ConcreteSubfloor
a.Concreteshallbecheckedforflatnesspriortoinstallation,lowspotsandvoidsshallbefilledtoa
minimumof3/16ina10ft.radiusor1/8ina6footradius.
b.Surfaceshouldbesmooth,cleanandfreeofcontaminants.
2. WoodSubfloor
a.3/4CDXplywoodfor24oncenterfloors.
b.5/8CDXplywoodfor12oncenterand16oncenterfloors.

2.3 ACCESSORIES

A. Treads:113/4(297mm)wideby1(25mm)thickin48(1220mm)lengthsand72
(1830mm)length.Matchcolor.
B. StairRiser:71/2(190mm)wideby7/16(12mm)thickin48(1220mm)lengthsand
72(1830mm).Matchcolor.
C. StairNosing:35/8(93mm)wideby9/16(14mm)thick.Matchcolor.
D. Reducer:21/4(54mm)wideby3/4(20mm)thick.Matchcolor.
E. TMolding:13/4(44mm)wideby5/8(16mm)thick.Matchcolor.
F. BaseShoe:3/4(19mm)highby1/2(13mm)thick.Matchcolor.
G. BaseBoard:3(77mm)highby11/4(30mm)thick.Matchcolor.
H. TThreshold:115/16(50mm)wideby13/16(22mm)thickin72(1830mm)lengths.Matchcolor.

Insertadditionalaccessoriessuchasmetalorwoodfeatureitemshere.Coordinateinstallationoftransitionstripsto
otherflooringmaterialsandfinishedfloorheights,ifapplicable,anddeterminewhichflooringinstallershould
providetransitionmaterials.
Iftransitionstripstootherflooringmaterialsarerequired,verifywhichflooringinstaller.
Providethetransitionsandincludebeloworinanothersectionasappropriate.

Part3EXECUTION
3.1 EXAMINATION

A. Examinesubstratesuponwhichbambooflooringwillbeinstalled.

1. Verifythatsubfloorisstructurallysound,clean,dry,andfreeofcontaminantsthatwouldinterfere
withbondingoftheflooringadhesive(suchasconcretecuringcompounds,waxesoroils).
2. Inwoodframestructures,donotbegininstallationofbambooflooringuntilstructurehasbeen
driedout,withmoisturecontentofwoodsubfloorbetween6and10percent.

09640Page5
Mr.Bamboo,Inc.
PrefinishedBambooFlooring
CSIMasterformat3PartSpecification

Thefollowingparagraphsapplyonlytobambooflooringinstalledoverconcretesubstrates.

3. TestconcretefloorsformoisturevaporemissionusingaCalciumChloridetest.Donotinstall
bambooflooringifvaporpressureexceeds3lbsper1,000squarefeet(15gperm2)in24hours.
4. VerifythatHVACsystemisoperatingandmaintainingoccupancyleveltemperatureandhumidity
conditions.ReportunsatisfactoryconditionstoArchitectand/orGeneralContractorandcorrect
beforeproceeding.Commencementofworkbyinstallerisconsideredanacceptanceofsubstrate
conditions.Priortoinstallation,theinstallershallexamineallmaterialanddeterminethatit
matchestheworkorder.

3.2 PREPARATION

A. Acclimatization:Openbambooflooringboxesandremovepackagingaminimum3dayspriortostartof
installation.

B. Grindandfillsubfloorusingmethodsandmaterialsappropriatetothesubfloorconstructiontoeliminate
humpsanddepressions.Forbestresults,neitherhumpsnordepressionsshallexceed1/8(3mm)ina6
foot(1830mm)radiusor3/16(4.7mm)ina10foot(3048mm)radius.

C. Cleansurfacethoroughlypriortoinstallation.

D. Duetothephysicalcharacteristicsofbamboo,itisanaturalfiber.Variationsincoloroccurnaturally.Each
boxshouldbeinspectedfordifferencesincolorandcolorvarianceshouldbestaggeredthroughoutthe
floor.

3.3 INSTALLATION
Undernormalinstallationconditions,themanufacturersinstallationinstructionsaresufficient.Unusualorunique
siteordesignconditionsmaydemandsupplementaryinformationinthisarticle.

A. BambooFlooring:Installinaccordancewithmanufacturerscompleteinstallationinstructionsby[nailingor
staplingtosubstrate][gluingtosubstrate.]Detailsbelowareasummaryonly.

B. Laybambooflooringinthedirection(s)/pattern(s)asshownonDrawings.

C. Forablendedappearanceselectpiecesrandomlyfromseveralboxes.

D. Allow1/4(5mm)spaceforexpansionandmovementofbambooflooringatwallsandpermanent
obstructions.

Includethefollowingparagraphsifadhesiveinstallationmethodisused.

E. Donotusethewetlayorlooselayinstallationmethod.Thismethodwilltrapmoistureunderthefloor
andcouldcausethebambooflooringtowarp.Spreadadhesiveascanbecoveredwithanappropriate
notchedtrowelat45degreeangle.Spreadasmuchadhesiveascanbecoveredbyflooringinonehour(or
asrecommendedbyyouradhesiveinstruction.)Onceadhesivehastacked,laythefirstrowofbamboo
flooringandcontinuelayingflooringuntiladhesiveiscovered.

09640Page6
Mr.Bamboo,Inc.
PrefinishedBambooFlooring
CSIMasterformat3PartSpecification

F. Adherebambooflooringstripswithoutgaps.Ensurethateachfloorstripiscompletelyadheredto
substrate.

G. Immediatelyremoveexcessadhesivefromprefinishedsurfaceofbambooflooring.

Includethefollowingparagraphsifnaildowninstallationmethodisused.

H. Laystripbambooflooringoverwoodsubfloorparallelwithlengthofroom.

I. Naildownbambooflooringtosubfloorwithpowerdriver.Spacefastenersat610(152254mm)and
2(51mm)fromendofboards.Staggerendjointsfromrowtorowbyminimumof12(305mm).

J. Accessories:Installusingmethodsappropriatetotheaccessoryandflooringsystem.

K.Accommodatethermalexpansion.Installtransitions,trimandbasemolding,asidentifiedin
manufacturersinstallationguidelinesandasrequiredtoaccommodatesiteconditions.

3.4 CLEANING

A. ReferenceSection01740Maintenance.

B. Followmanufacturersrecommendedmaintenanceinstruction.

3.5 PROTECTION

CoverandprotectcompletedMr.Bambooflooringfromfurtherconstructiontrafficwithheavykraftpaperorother
suitablecovering.Donotusenonbreathablesheetorfilmthatcouldcausecondensationtoform.Maintaincovering
throughoutremainderofconstructionperiod.

ENDOFSECTION

ThisspecificationwaspreparedbyMr.Bamboo,Inc.55KellyStreet,ElkGroveVillage,IL60007or18886722628
www.mrbambooflooring.comEmail:info@mrbambooflooring.com.
2008Allrightsreserved.

Vous aimerez peut-être aussi