Steel Beam

ENERCALC, INC. 1983-2011, Build:6.11.6.23, Ver:6.11.6.23


Licensee : Lic. # :
File: P:\7) Boccella Residence\Calculations\Enercalc\ROOF BEAMS.ec6
Description : RB13 BENT
Calculations per AISC 360-05, IBC 2009, CBC 2010, ASCE 7-05 Material Properties
Analysis Method :
ksi
Bending Axis : Major Axis Bending
Load Combination :2009 IBC & ASCE 7-05
Beam bracing is defined as a set spacing over all spans
Allowable Stress Design Fy : Steel Yield : 50.0 ksi
Beam Bracing : E: Modulus : 29,000.0
Unbraced Lengths
First Brace starts at ft from Left-Most support
Regular spacing of lateral supports on length of beam =4.0 ft
W6X16
Span =16.50 ft
W6X16
D(0.28) Lr0.34) D(0.84) Lr1.06)
D(0.0805,0) Lr(0.115,0)
D(0.028) Lr(0.04)
D(0.1225) Lr(0.175)
D(0.028) Lr(0.04)
Service loads entered. Load Factors will be applied for calculations.
Applied Loads
Beam self weight calculated and added to loads
Load for Span Number 1
Varying Uniform Load : D(S,E) = 0.0140->0.0, Lr(S,E) = 0.020->0.0 ksf, Extent = 0.0 -->> 8.50 ft, Trib Width = 5.750->0.0 ft, (ROOF)
Uniform Load : D = 0.0140, Lr = 0.020 ksf, Extent = 8.50 -->> 10.50 ft, Tributary Width = 2.0->0.0 ft, (ROOF)
Uniform Load : D = 0.0140, Lr = 0.020 ksf, Extent = 10.50 -->> 16.50 ft, Tributary Width = 8.750->0.0 ft, (ROOF)
Point Load : D = 0.280, Lr = 0.340 k @8.50 ft, (FR 2-RB10 LEFT)
Point Load : D = 0.840, Lr = 1.060 k @10.50 ft, (FR 2-RB12 LEFT)
Uniform Load : D = 0.0140, Lr = 0.020 ksf, Extent = 10.50 -->> 16.50 ft, Tributary Width = 2.0->0.0 ft, (OVERBUILD)
Design OK DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.520: 1
Load Combination +D+Lr+H
Span # where maximum occurs Span # 1
Location of maximum on span 10.478ft
3.677 k
Mn / Omega : Allowable 29.192k-ft Vn/Omega : Allowable
W6X16
Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination +D+Lr+H
32.656 k
Section used for this span
W6X16
Mu : Applied
Maximum Shear Stress Ratio = 0.113 : 1
16.500 ft
15.180k-ft Vu : Applied
0 <240
275
Ratio = 0 <180
Maximum Deflection
Max Downward L+Lr+S Deflection 0.393 in 504 Ratio =
Max Upward L+Lr+S Deflection 0.000 in
Ratio =
Max Downward Total Deflection 0.720 in
Ratio =
Max Upward Total Deflection 0.000 in
Location in Span Load Combination Max. "-" Defl Location in Span Load Combination Span Max. "+" Defl
Overall Maximum Deflections - Unfactored Loads
1 0.0000 0.000 0.0000 0.000
Load Combination Support 1 Support 2
Vertical Reactions - Unfactored
Support notation : Far left is #1 Values in KIPS
Overall MAXimum 2.269 3.677
D Only 1.046 1.642
Lr Only 1.224 2.035
D+Lr 2.269 3.677