Manual de Ingeniera ADS HIDRULICA 3-1

ADS, Diciembre 2010


3-0 HIDRULICA
TABLA DE CONTENIDOS
3-1 Consideraciones Hidrulicas .......................................................... 3-2
3-2 Valores n de Manning de Diseo.................................................. 3-2
3-3 Curvas de Descarga ......................................................................... 3-3
3-4 El Mtodo de Conduccin ................................................................ 3-6
3-5 Velocidad Mnima............................................................................. 3-11
3-6 Velocidad Mxima............................................................................ 3-11
3-7 Presiones Constantes..................................................................... 3-12
3-8 Alcantarillas de Camino.................................................................. 3-13
3-9 Ejemplos .......................................................................................... 3-14
3-10 Referencias...................................................................................... 3-16
Figuras
3-1 Tasas de Descarga para Tuberas Corrugadas de Interior Liso
ADS...3-5
3-2 Tasas de Descarga para Tuberas de Pared Simple ADS .....3-6
Tablas
3-1 Valores de Diseo n de Manning para Productos ADS........3-8
3-2a Factores de Conduccin (Unidades Estndar) .................................. 3-9
3-2b Factores de Conduccin (Unidades Mtricas) ................................ 3-10
3-3 Coeficientes de Prdida de Carga en la Entrada......................... 3-14
El COMPRADOR/USUARIO ES RESPONSABLE DEL NIVEL DE SERVICIO DEL PRODUCTO EN CUALQUIER
APLICACIN DADA. EL VENDEDOR NO ES RESPONSABLE POR LESIONES O DAOS RESULTANTES DE UNA
INSTALACIN INCORRECTA, EL NO CUMPLIMIENTO DE LAS PRESENTES DIRECTRICES PARA LA INSTALACIN
DEL PRODUCTO, O SU USO FUERA DE LAS RECOMENDACIONES ESTABLECIDAS EN EL PRESENTE
DOCUMENTO.
Manual de Ingeniera ADS HIDRULICA 3-2
ADS, Diciembre 2010
3-1 CONSIDERACIONES HIDRAULICAS
La ecuacin de Manning es la forma ms reconocida para determinar la
capacidad de flujo conduccin de una tubera en aplicaciones de
conduccin flujo gravitacional. Es as comoComo tal, proporciona la base
de la consideracin del diseo hidrulico para la tubera corrugada de el
polietileno corrugado de alta densidad (o HDPE, por su sigla en ingls) y
la tubera de polipropileno (PP).
Una vez definidas la capacidad requerida y la pendiente de diseo del
proyecto, Llas curvas de descarga permiten eldimensionar calibrado de
la tubera por medio del uso de grficasgrficos, una vez que se haya
establecido el diseo de los requisitos de capacidad y e inclinacin. Cada
producto tendr asociada su propia curva de descarga con base en su
valor n de Manning. Esta seccin proporciona capacidades de flujo
segn los valores n de diseo recomendados para los productos Tigre-
ADS. Algunos factores como curvas, conexiones a cmaras, escombros
y sedimentos, entre otros, tienen como resultado prdidas hidrulicas que
afectarn la capacidad de flujo real y debieran ser consideradas al
momento de seleccionar la tubera.
Al reducir todos los coeficientes y constantes en la ecuacin de Manning
a un solo factor, llamado Factor de Conduccin (K), se puede utilizar otra
alternativa de mtodo para la determinacin del tamao de las tuberas.
Sabiendo el valor n de Manning para diferentes materiales de tuberas,
el uso de tablas de factores de conduccin permitir al diseador
comparar fcilmente diversas opciones de productos. El uso de este
mtodo frecuentemente resulta en ms de una clase y tamao de
tuberas que pueden ser factibles para un mismo proyecto, permitiendo al
diseador comparar opciones y determinar la mejor solucin segn
anlisis costo-beneficio.
En la seleccin final de una tubera debiera incluirse tambin una revisin
de las velocidades de conduccin. Velocidades mayores ayudan a que
los sedimentos en las aguas pluviales u otros no se mantengan en el
fondo de la tubera. Menor sedimentacin implica adems reduccin en
la frecuencia del mantenimiento, permitiendo que la funcin hidrulica de
la tubera se mantenga a lo largo de su vida til. No obstante, estas
velocidades igualmente deben estar dentro de los lmites mximos
aceptables para cada tubera y su sistema asociado.
3-2 VALORES n DE MANNING DE DISEO
Dentro de la industria de tuberas, existe un amplio rango de valores para
el coeficiente de rugosidad n de Manning para diversos tipos de tubos.
Cuando se disea cualquier sistema con flujo gravitacional, es importante
considerar varios aspectos antes de seleccionar un valor n para un
material de tubera especfico.
Manual de Ingeniera ADS HIDRULICA 3-3
ADS, Diciembre 2010
1. Los valores n de Manning para cualquier material de tubera
dependern de la altura del flujo en una tubera parcialmente llena y
de la velocidad del flujo en condicin de tubo lleno. Los valores n de
Manning comnmente se proporcionan para condiciones de flujo a
tubo lleno, pero esto no debiese asumirse a menos que se seale
especficamente. Para la mayora de los clculos, se asume que n
es una constante; sin embargo, queda a criterio del diseador el usar
un valor constante o variable para n.
2. Las alcantarillas, drenajes pluviales y drenajes sanitarios estn
expuestos a la presencia de basuras y sedimentos en su interior, los
cuales afectan negativamente la capacidad de conduccin. Cuando
esto ocurre, es recomendable ajustar el valor n de diseo de
acuerdo a estas condiciones. La textura de la pared interna del tubo,
su geometra, la separacin de las uniones y el tipo de material de la
tubera tambin pueden facilitar o no la presencia de basuras y
sedimentos, dependiendo de la facilidad de estas partculas de
adherirse a la superficie de la tubera o quedar atrapada en otras
obstrucciones internas.
Pruebas realizadas en el Laboratorio de Investigacin del Agua de la
Universidad Estatal de Utah (Utah State University Water Research
Laboratory), entregan valores n de Manning mnimos menores a 0,010
para una tubera corrugada de HDPE con pared interna lisa. Con el fin de
adaptarse a las condiciones reales de terreno e incorporando un factor
seguridad, Tigre-ADS recomienda usar un valor n de Manning entre
0.010 y 0.012, para productos corrugados de polietileno de alta densidad
con pared interior lisa. En general, es una prctica comn en ingeniera
incluir un factor seguridad del 20% al 30% a los valores Manning
determinados en pruebas de laboratorio Esto implicara utilizar un n de
Manning de 0.012 como valor de diseo paras tuberas corrugadas de
interior liso Tigre-ADS. La Tabla 3-1 muestra valores n de Manning
recomendados para diferentes productos de tuberas Tigre-ADS.
3-3 CURVAS DE DESCARGA
La relacin matemtica entre los trminos incluidos en la frmula de
Manning a menudo se muestra por medio de Curvas de Descarga. Las
curvas de descarga son un mtodo para seleccionar un tamao de
tubera adecuado, una vez que se han determinado la capacidad
requerida y la pendiente.
Las curvas de descarga para los productos de tuberas corrugadas de
polietileno de alta densidad ADS bajo condiciones estables de flujo
gravitacional se muestran en las Figuras 3-1 a la 3-2.
Manual de Ingeniera ADS HIDRULICA 3-4
ADS, Diciembre 2010
Figura 3-1
Tasas de Descarga para Tuberas Corrugadas de Interior Liso Tigre-ADS (N-12, N-12 ST y N-12
WT).
Nota: - Basado en los valores n de Manning de diseo sealados en la Tabla 3-1, segn dimetro
correspondiente.
- La tubera puede no estar disponible en todos los dimetros mostrados.
- Las lneas slidas indican los dimetros de la tubera. Las lneas punteadas indican la velocidad
promedio aproximada.
1cfs = 0.02832 m
3
/s
1ft/s = 0.30480 m/s
1% = 0.01 ft/ft
0. 10
1. 00
10. 00
100. 00
1000. 00
0
.
0
1
%
0
.
1
0
%
1
.
0
0
%
1
0
.
0
0
%
S l op e of pi pe i n fe e t pe r 100ft (%sl op e )
F
l
o
w

c
a
p
a
c
i
t
y

(
c
f
s
)
300. 00
400. 00
500. 00
200. 00
20. 00
3. 00
2. 00
50. 00
40. 00
30. 00
0. 50
0. 40
0. 30
0. 20
5. 00
4. 00
8 fps (2. 4m / s )
40 f ps ( 12. 2m/s )
35 f ps ( 10. 7m/s )
31 f ps ( 9. 4m/s )
27 fps (8. 2m / s )
25 fps (7. 6m / s )
23 fps (7. 0m / s )
21 fps (6. 4m / s )
19 fps (5. 8m / s )
17 fps (5. 2m / s )
15 fps (4. 6m / s )
13 fps (4. 0m / s )
10 fps (3. 0m / s )
9 fps (2. 7m / s )
0
.
0
2
%
0
.
0
3
%
0
.
0
5
%
0
.
0
4
%
0
.
2
0
%
0
.
3
0
%
0
.
5
0
%
0
.
4
0
%
2
.
0
0
%
3
.
0
0
%
5
.
0
0
%
4
.
0
0
%
6

(1
5
0
m
m
)
8

(2
0
0
m
m
)
1
0

(2
5
0
m
m
)
1
2

(3
0
0
m
m
)
1
5

(3
7
5
m
m
)
1
8

(4
5
0
m
m
)
2
4

(6
0
0
m
m
)
3
0

(7
5
0
m
m
)
3
6

(9
0
0
m
m
)
4
2

(1
0
5
0
m
m
) 4
8

(1
2
0
0
m
m
)
6
0

(1
5
0
0
m
m
)
5
4

(1
3
5
0
m
m
)
1
f
p
s

(
0
.
3
m
/
s
)
2
f
p
s

(
0
.
6
m
/
s
)
3
f
p
s

(
0
.
9
m
/
s
)
4
f
p
s

(
1
.
2
m
/
s
)
5
f
p
s

(
1
.
5
m
/
s
)
6
f
p
s

(
1
.
8
m
/
s
)
7
f
p
s

(
2
.
1
m
/
s
)
4

(1
0
0
m
m
)
0. 10
1. 00
10. 00
100. 00
1000. 00
0
.
0
1
%
0
.
1
0
%
1
.
0
0
%
1
0
.
0
0
%
S l op e of pi pe i n fe e t pe r 100ft (%sl op e )
F
l
o
w

c
a
p
a
c
i
t
y

(
c
f
s
)
300. 00
400. 00
500. 00
200. 00
20. 00
3. 00
2. 00
50. 00
40. 00
30. 00
0. 50
0. 40
0. 30
0. 20
5. 00
4. 00
8 fps (2. 4m / s )
40 f ps ( 12. 2m/s )
35 f ps ( 10. 7m/s )
31 f ps ( 9. 4m/s )
27 fps (8. 2m / s )
25 fps (7. 6m / s )
23 fps (7. 0m / s )
21 fps (6. 4m / s )
19 fps (5. 8m / s )
17 fps (5. 2m / s )
15 fps (4. 6m / s )
13 fps (4. 0m / s )
10 fps (3. 0m / s )
9 fps (2. 7m / s )
0
.
0
2
%
0
.
0
3
%
0
.
0
5
%
0
.
0
4
%
0
.
2
0
%
0
.
3
0
%
0
.
5
0
%
0
.
4
0
%
2
.
0
0
%
3
.
0
0
%
5
.
0
0
%
4
.
0
0
%
6

(1
5
0
m
m
)
8

(2
0
0
m
m
)
1
0

(2
5
0
m
m
)
1
2

(3
0
0
m
m
)
1
5

(3
7
5
m
m
)
1
8

(4
5
0
m
m
)
2
4

(6
0
0
m
m
)
3
0

(7
5
0
m
m
)
3
6

(9
0
0
m
m
)
4
2

(1
0
5
0
m
m
) 4
8

(1
2
0
0
m
m
)
6
0

(1
5
0
0
m
m
)
5
4

(1
3
5
0
m
m
)
1
f
p
s

(
0
.
3
m
/
s
)
2
f
p
s

(
0
.
6
m
/
s
)
3
f
p
s

(
0
.
9
m
/
s
)
4
f
p
s

(
1
.
2
m
/
s
)
5
f
p
s

(
1
.
5
m
/
s
)
6
f
p
s

(
1
.
8
m
/
s
)
7
f
p
s

(
2
.
1
m
/
s
)
4

(1
0
0
m
m
)
Manual de Ingeniera ADS HIDRULICA 3-5
ADS, Diciembre 2010
Figura 3-2
Tasas de Descarga para Tuberas de Pared Simple ADS (SW, Heavy Duty)
Nota: - Basado en los valores n de Manning de diseo sealados en la Tabla 3-1, segn dimetro
correspondiente.
- La tubera puede no estar disponible en todos los dimetros mostrados.
- Las lneas slidas indican los dimetros de la tubera. Las lneas punteadas indican la velocidad
promedio aproximada.
1cfs = 0.02832 m
3
/s
1ft/s = 0.30480 m/s
1% = 0.01 ft/ft
3

(
7
5
m
m
)
0.10
1.00
10.00
100.00
0
.
0
1
%
0
.
1
0
%
1
.
0
0
%
1
0
.
0
0
%
Slope of pipe in fe e t pe r 1 0 0 ft (%s lope )
F
l
o
w

c
a
p
a
c
i
t
y

(
c
f
s
)
20.0 0
3. 00
2 .00
50.0 0
40.0 0
30.0 0
0 .50
0 .40
0 .30
0 .20
5. 00
4. 00
8 f ps ( 2.4 m/ s )
1 0 f ps ( 3 .0m/s )
9 f ps ( 2.7 m/ s )
7 f ps ( 2.1m/s )
5 f ps ( 1.5 m/ s )
6 f ps ( 1.8m/s )
0
.
0
2
%
0
.
0
3
%
0
.
0
4
%
0
.
0
5
%
0
.
2
0
%
0
.
3
0
%
0
.
4
0
%
0
.
5
0
%
2
.
0
0
%
3
.
0
0
%
4
.
0
0
%
5
.
0
0
%
6

(
1
5
0
m
m
)
8

(
2
0
0
m
m
)
1
0

(
2
5
0
m
m
)
1
2

(
3
0
0
m
m
)
1
5

(
3
7
5
m
m
) 1
8

(
4
5
0
m
m
)
2
4

(
6
0
0
m
m
)
4

(
1
0
0
m
m
)
1
f
p
s

(
0
.
3
m
/
s
)
2
f
p
s

(
0
.
6
m
/
s
)
3
f
p
s

(
0
.
9
m
/
s
)
4
f
p
s

(
1
.
2
m
/
s
)
Manual de Ingeniera ADS HIDRULICA 3-6
ADS, Diciembre 2010
3-4 EL MTODO DE CONDUCCIN
El Mtodo de Conduccin (Conveyance Method, en ingls) es una
forma prctica para seleccionar varias opciones de tuberas que
satisfagan los requerimientos de capacidad de flujo de un proyecto.
Los factores de conduccin se basan en una versin muy simplificada
de la ecuacin de Manning mostrada en la Ecuacin 3-1 y 3-1(a). El
anlisis, los ejemplos de problemas y las secciones siguientes
asumen que el flujo en la tubera es a tubo lleno. Este supuesto
permite un anlisis simplificado pero an as preciso de las
condiciones dadas. Cada proyecto debe ser evaluado caso a caso
para determinar el mejor y ms representativo mtodo de diseo.
Ecuacin 3-1
Donde:
Q = capacidad de la tubera, (ft
3
/s, pies cbicos por segundo)
n = n de Manning
A = rea de la seccin transversal de flujo del tubo (ft
2
, pies
cuadrados)
R = radio hidrulico (ft, pies):
P = Permetro mojado (ft, pies); (Circunferencia interna de la
tubera, o () (dimetro interno) para condiciones de flujo a
tubo lleno)
S = pendiente del tubo (ft/ft)
O, en unidades mtricas:
Ecuacin 3-1(a)
Donde:
Q = capacidad de la tubera, (m3/s)
n = n de Manning
A = rea de la seccin transversal de flujo del tubo (m2)
R = radio hidrulico (m):
P = Permetro mojado (m); (Circunferencia interna de la tubera,
o () (dimetro interno) para condiciones de flujo a tubo
lleno)
n
) S )( R )( A )( 486 . 1 (
Q
2 / 1 3 / 2
=
Manual de Ingeniera ADS HIDRULICA 3-7
ADS, Diciembre 2010
S = pendiente del tubo (m/m)
Para una instalacin especfica con flujo a tubo lleno, los parmetros
n, A y R se pueden definir fcilmente como constantes. La capacidad
de transporte o factor de conduccin de la tubera puede ser definida
como se muestra en la Ecuacin 3-2 o 3-2(a).
Ecuacin 3-2
O, en unidades mtricas:
Ecuacin 3-2(a)
Por sustitucin, la frmula de Manning puede reducirse a la siguiente
ecuacin:
Ecuacin 3-3
La Ecuacin 3-3 puede tambin escribirse como se muestra en la
Ecuacin 3-4.
Ecuacin 3-4
La sustitucin directa de las condiciones de diseo en la Ecuacin 3-4
determinar el factor de conduccin mnimo admisible. La Tabla 3-2a
o la 3-2b se usan entonces como referencia para seleccionar la
tubera tomando un factor de conduccin al menos igual o mayor al
calculado.
Las Tablas 3-2a y 3-2b requieren conocer valor n de Manning. Estas
tablas pueden ser usadas tambin para cualquier material si se
conoce su n de Manning especfico.
El n de Manning es un valor crtico en el concepto de conduccin.
Para tuberas de un mismo dimetro e inclinacin, el parmetro n de
Manning ser el nico factor que afectar el factor conduccin y, por
lo tanto, la capacidad del tubo. Cuando se comparan condiciones
idnticas, el factor de conduccin tiene una relacin directa con la
capacidad del tubo. Es decir, si la inclinacin se mantiene constante,
triplicar el factor de conduccin triplicar la capacidad; dividir en dos el
factor de conduccin reducir la capacidad a la mitad.
Algunos ejemplos de problemas que involucran factores de
conduccin son presentados ms adelante.
Manual de Ingeniera ADS HIDRULICA 3-8
ADS, Diciembre 2010
Tabla 3-1
Valores de Diseo n de Manning para productos ADS
Valores n de Manning de Diseo para Tubera corrugada de HDPE ADS *
Producto Dimetro Diseo de n de Manning
N-12,
N-12 ST IB,
N-12 WT IB
100 a 1500 mm
(4 - 60)
n = 0,012
Pared Simple, (SW) **
450 a 600 mm(18 - 24)
300 a 375 mm(12 - 15)
250 mm (10)
200 mm (8)
75 a 150 mm (3 - 6)
n = 0,020
n = 0,018
n = 0,017
n = 0,016
n = 0,015
Ecuaciones de Conduccin: k = Q/(s^0,5) Q = k s^0,5
* Corrugated Polyethylene Pipe Association (2000), Hydraulic Considerations for Corrugated Polyethylene Pipe
(Asociacin de Tuberas de Polietileno Corrugado, Consideraciones hidrulicas para tuberas de polietileno corrugado).
** En Chile, los dimetros disponibles para tubera SW son (4 y 6). Consulte a su proveedor local para otros dimetros.
Manual de Ingeniera ADS HIDRULICA 3-9
ADS, Diciembre 2010
Tabla 3-2a
Factores de Conduccin (Unidades Estndar)
Factores de Conduccin para Tubera Circular con Flujo a Tubo Lleno
Valores "n" de Manning
Dia.
(pulg)
Area
(ft
2
) 0.009 0.010 0.011 0.012 0.013 0.014 0.015 0.016 0.017 0.018 0.019 0.020 0.021 0.022 0.023 0.024 0.025
3 0.05 1.3 1.1 1.0 1.0 0.9 0.8 0.8 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5
4 0.09 2.7 2.5 2.2 2.1 1.9 1.8 1.6 1.5 1.5 1.4 1.3 1.2 1.2 1.1 1.1 1.0 1.0
6 0.20 8.1 7.3 6.6 6.1 5.6 5.2 4.9 4.6 4.3 4.1 3.8 3.6 3.5 3.3 3.2 3.0 2.9
8 0.35 17.5 15.7 14.3 13.1 12.1 11.2 10.5 9.8 9.2 8.7 8.3 7.9 7.5 7.1 6.8 6.5 6.3
10 0.55 31.6 28.5 25.9 23.7 21.9 20.3 19.0 17.8 16.8 15.8 15.0 14.2 13.6 12.9 12.4 11.9 11.4
12 0.79 51.5 46.3 42.1 38.6 35.6 33.1 30.9 28.9 27.2 25.7 24.4 23.2 22.1 21.1 20.1 19.3 18.5
15 1.23 93.3 84.0 76.3 70.0 64.6 60.0 56.0 52.5 49.4 46.7 44.2 42.0 40.0 38.2 36.5 35.0 33.6
18 1.77 151.7 136.6 124.1 113.8 105.0 97.5 91.0 85.3 80.3 75.9 71.9 68.3 65.0 62.1 59.4 56.9 54.6
21 2.41 228.9 206.0 187.3 171.6 158.4 147.1 137.3 128.7 121.2 114.4 108.4 103.0 98.1 93.6 89.6 85.8 82.4
24 3.14 326.8 294.1 267.3 245.1 226.2 210.1 196.1 183.8 173.0 163.4 154.8 147.0 140.0 133.7 127.9 122.5 117.6
27 3.98 447.3 402.6 366.0 335.5 309.7 287.6 268.4 251.6 236.8 223.7 211.9 201.3 191.7 183.0 175.0 167.8 161.0
30 4.91 592.5 533.2 484.7 444.3 410.2 380.9 355.5 333.3 313.7 296.2 280.6 266.6 253.9 242.4 231.8 222.2 213.3
33 5.94 763.9 687.5 625.0 572.9 528.9 491.1 458.3 429.7 404.4 382.0 361.9 343.8 327.4 312.5 298.9 286.5 275.0
36 7.07 963.4 867.1 788.2 722.6 667.0 619.3 578.0 541.9 510.0 481.7 456.4 433.5 412.9 394.1 377.0 361.3 346.8
42 9.62 1453.2 1307.9 1189.0 1089.9 1006.1 934.2 871.9 817.5 769.4 726.6 688.4 654.0 622.8 594.5 568.7 545.0 523.2
45 11.04 1746.8 1572.1 1429.2 1310.1 1209.3 1122.9 1048.1 982.6 924.8 873.4 827.4 786.1 748.6 714.6 683.5 655.0 628.8
48 12.57 2074.8 1867.4 1697.6 1556.1 1436.4 1333.8 1244.9 1167.1 1098.4 1037.4 982.8 933.7 889.2 848.8 811.9 778.1 746.9
54 15.90 2840.5 2556.4 2324.0 2130.4 1966.5 1826.0 1704.3 1597.8 1503.8 1420.2 1345.5 1278.2 1217.4 1162.0 1111.5 1065.2 1022.6
60 19.63 3762.0 3385.8 3078.0 2821.5 2604.4 2418.4 2257.2 2116.1 1991.6 1881.0 1782.0 1692.9 1612.3 1539.0 1472.1 1410.7 1354.3
72 28.27 6117.3 5505.6 5005.1 4588.0 4235.1 3932.6 3670.4 3441.0 3238.6 3058.7 2897.7 2752.8 2621.7 2502.5 2393.7 2294.0 2202.2
Manual de Ingeniera ADS HIDRULICA 3-10
ADS, Diciembre 2010
Tabla 3-2b
Factores de Conduccin (Unidades Mtricas)
Factores de Conduccin para Tubera Circular con Flujo a Tubo Lleno
Valores "n" de Manning
Dia.
(mm)
Area
(m
2
) 0.009 0.010 0.011 0.012 0.013 0.014 0.015 0.016 0.017 0.018 0.019 0.020 0.021 0.022 0.023 0.024 0.025
75 0.004 0.03 0.03 0.03 0.03 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01
100 0.008 0.07 0.07 0.06 0.06 0.05 0.05 0.04 0.04 0.04 0.04 0.04 0.03 0.03 0.03 0.03 0.03 0.03
150 0.018 0.22 0.20 0.18 0.16 0.15 0.14 0.13 0.12 0.12 0.11 0.10 0.10 0.09 0.09 0.09 0.08 0.08
200 0.031 0.47 0.43 0.39 0.36 0.33 0.30 0.28 0.27 0.25 0.24 0.22 0.21 0.20 0.19 0.19 0.18 0.17
250 0.049 0.86 0.77 0.70 0.64 0.59 0.55 0.52 0.48 0.45 0.43 0.41 0.39 0.37 0.35 0.34 0.32 0.31
300 0.071 1.40 1.26 1.14 1.05 0.97 0.90 0.84 0.79 0.74 0.70 0.66 0.63 0.60 0.57 0.55 0.52 0.50
375 0.110 2.53 2.28 2.07 1.90 1.75 1.63 1.52 1.42 1.34 1.27 1.20 1.14 1.09 1.04 0.99 0.95 0.91
450 0.159 4.12 3.71 3.37 3.09 2.85 2.65 2.47 2.32 2.18 2.06 1.95 1.85 1.76 1.68 1.61 1.54 1.48
525 0.216 6.21 5.59 5.08 4.66 4.30 3.99 3.73 3.49 3.29 3.11 2.94 2.80 2.66 2.54 2.43 2.33 2.24
600 0.283 8.87 7.98 7.26 6.65 6.14 5.70 5.32 4.99 4.70 4.43 4.20 3.99 3.80 3.63 3.47 3.33 3.19
675 0.358 12.14 10.93 9.93 9.11 8.41 7.80 7.28 6.83 6.43 6.07 5.75 5.46 5.20 4.97 4.75 4.55 4.37
750 0.442 16.08 14.47 13.16 12.06 11.13 10.34 9.65 9.04 8.51 8.04 7.62 7.24 6.89 6.58 6.29 6.03 5.79
825 0.535 20.73 18.66 16.96 15.55 14.35 13.33 12.44 11.66 10.98 10.37 9.82 9.33 8.89 8.48 8.11 7.77 7.46
900 0.636 26.15 23.53 21.39 19.61 18.10 16.81 15.69 14.71 13.84 13.07 12.39 11.77 11.21 10.70 10.23 9.81 9.41
1050 0.866 39.44 35.50 32.27 29.58 27.31 25.36 23.67 22.19 20.88 19.72 18.68 17.75 16.90 16.14 15.43 14.79 14.20
1125 0.994 47.41 42.67 38.79 35.56 32.82 30.48 28.45 26.67 25.10 23.70 22.46 21.33 20.32 19.39 18.55 17.78 17.07
1200 1.131 56.31 50.68 46.07 42.23 38.99 36.20 33.79 31.68 29.81 28.16 26.67 25.34 24.13 23.04 22.04 21.12 20.27
1350 1.431 77.09 69.38 63.08 57.82 53.37 49.56 46.26 43.36 40.81 38.55 36.52 34.69 33.04 31.54 30.17 28.91 27.75
1500 1.767 102.10 91.89 83.54 76.58 70.69 65.64 61.26 57.43 54.05 51.05 48.36 45.95 43.76 41.77 39.95 38.29 36.76
1800 2.545 166.04 149.43 135.85 124.53 114.95 106.74 99.62 93.62 87.90 83.02 78.65 74.72 71.16 67.92 64.97 62.26 59.77
Manual de Ingeniera ADS HIDRULICA 3-11
ADS, Diciembre 2010
3-5 VELOCIDAD MNIMA
La presencia de sedimentos puede reducir la capacidad de una tubera a
lo largo del tiempo. En algunos proyectos, la tubera incluso puede llegar a
quedar inutilizable hasta que el sistema vuelva a ser limpiado, lo cual
implica trabajos de alto costo y que pueden tomar bastante tiempo. La
sedimentacin es de especial consideracin en drenajes pluviales y
similares, donde elementos ms grandes y ms pesados pueden estar
presentes. Todo lo anterior hace importante tomar medidas preventivas al
respecto durante el diseo.
Para minimizar potenciales problemas, el flujo debe mantenerse a una
velocidad mnima o de auto-limpieza. La velocidad de auto-limpieza
comnmente aceptada para alcantarillas pluviales y sanitarias es de 0.9
m/s (3 fps). Para cada diseo debiese realizarse un chequeo final con el
fin de comparar la velocidad esperada con la velocidad de auto-limpieza.
La velocidad en tuberas con flujo a tubo lleno puede ser aproximada con
la Ecuacin 3-5.
V = Q/A Ecuacin 3-5
El potencial de sedimentacin se determina segn el peso especfico y
dimetro de las partculas, sus propiedades cohesivas y la rugosidad
interior de la tubera. En instalaciones particulares donde la presencia de
sedimentos es un problema conocido y predecible, es recomendable
realizar un anlisis de los suelos antes de hacer el diseo final del
proyecto.
Nota: Mayor informacin sobre las complejidades y variables asociadas en la
determinacin de la velocidad de auto-limpieza para un tipo y tamao de tubera
especfico, puede encontrarse en la publicacin ASCE No. 60 Gravity Sanitary
Sewer Design and Construction (Construccin y diseo de drenajes sanitarios
gravitacionales).
3-6 VELOCIDAD MXIMA
Un flujo a altas velocidades tambin puede generar problemas si no se
considera debidamente. Normalmente, por alta velocidad se entiende 3,7
m/s aprox., pero puede variar dependiendo de las condiciones especficas
del proyecto.
La mejor forma para lidiar con las altas velocidades es buscar formas de
minimizarla, como por ejemplo, reduciendo la pendiente de la tubera. Si
esto no es factible, simplemente se debe controlar la velocidad de la
mejor manera posible.
Manual de Ingeniera ADS HIDRULICA 3-12
ADS, Diciembre 2010
Altas velocidades, especialmente con escurrimientos abrasivos, pueden
provocar problemas de durabilidad. Con el tiempo, la parte inferior de la
tubera puede desgastarse prematuramente. En este sentido, los
termoplsticos resisten mejor que muchos otros materiales de tuberas los
efectos de estas condiciones desfavorables. Para mayor informacin
sobre los efectos de la abrasin en varios tipos de materiales de tuberas,
consultar la seccin Durabilidad (Seccin 4) de este Manual.
Se requiere poner atencin especial a las condiciones generadas en la
salida de la tubera. Las altas velocidades de escurrimiento pueden
erosionar el rea o canal donde desemboca el flujo. En estos casos, se
recomienda considerar en esas zonas mtodos de manejo de la erosin.
Otro aspecto importante a tener en cuenta en aplicaciones a alta
velocidad es el manejo del momentum del flujo. Los cambios en la
direccin del escurrimiento generan grandes fuerzas ejercidas sobre las
paredes de las tuberas que pueden causar el movimiento de stas,
especialmente cuando son de gran dimetro, la velocidad es alta y el
suelo nativo tiene baja capacidad de soporte. La colocacin de machones
de concreto en las zonas de cambio de direccin, dimensionados segn
las condiciones particulares de terreno, permite controlar los efectos de
estas fuerzas de empuje.
Considerar sistemas de anclaje tambin puede ser necesario cuando la
velocidad es alta o cuando la pendiente de instalacin de la tubera es
importante. Los anclajes evitan que la tubera se deslice pendiente abajo
mientras est siendo instalada, y despus, a causa de la energa del flujo.
Esto es especialmente importante si el suelo nativo est sujeto a
movimiento o es inestable. Tigre-ADS no provee ni disea sistemas de
anclaje, sin embargo puede proporcionar informacin adicional en este
tema. Para mayor informacin sobre aplicaciones en grandes pendientes,
refirase a Instalaciones en Pendientes Pronunciadas, en la Seccin 5
de Instalacin de este Manual.
3-7 PRESIONES CONSTANTES
Los productos en tubera corrugada Tigre-ADS estn desarrollados
nicamente para aplicaciones de flujo gravitacional, a presin atmosfrica.
Nuestros productos no se recomiendan para presiones constantes o flujos
de presin intermitente, incluyendo proyectos con carga hidrulica
constante y aplicaciones de bombeo. Para recibir asistencia en la
seleccin de productos adecuados para una aplicacin particular,
contactar a un representante del rea tcnica de ADS.
.
Manual de Ingeniera ADS HIDRULICA 3-13
ADS, Diciembre 2010
3-8 ALCANTARILLAS DE CAMINO
Las alcantarillas son cortas en comparacin a un sistema de alcantarillado
pluvial o sanitario y se clasifican segn cul de los extremos (entrada o
salida) controla su capacidad de descarga.
Las pruebas de laboratorio y observaciones de terreno indican dos
condiciones principales de control de flujo para una alcantarilla: (1) control
de entrada y (2) control de salida. Si bien las condiciones de control de
entrada o de salida por lo general no existen en los sistemas de drenaje
pluvial o sanitario, cuando un sistema sea controlado por las condiciones
de entrada o salida, la prdida de carga hidrulica debido a la entrada o
salida debe tomarse en cuenta, y por esta razn, la frmula de Manning
no es el nico mtodo de dimensionamiento y seleccin de tuberas.
Mientras la teora de la conservacin de la energa afectar directamente
el diseo de una alcantarilla, ninguna frmula o procedimiento ha sido
desarrollado para disear todas las alcantarillas, debido a las numerosas
variables implicadas. El diseo de alcantarillas, por lo tanto, es
frecuentemente un proceso emprico, de ensayo y error.
Una de las variables tpicamente utilizadas en el diseo de alcantarillas es
el Coeficiente de Prdida de Carga en la Entrada (Ke). Estos coeficientes
Ke dependen en gran medida del tamao y la forma de la interfaz entre el
material de la alcantarilla y el fluido. Por ejemplo, una alcantarilla con
extremos de corte recto y aristas vivas resultar en un coeficiente de
prdida mayor que una alcantarilla con un borde biselado o redondeado.
En ausencia de ensayos y datos para tubos corrugados de polietileno de
alta densidad, y de acuerdo a lo recomendado por la bibliografa
internacional, es posible estimar los coeficientes de prdida de carga en la
entrada para los tubos Tigre-ADS, homologndolos a una tubera de
metal corrugado con perfil y estructura similar. La Tabla 3-3 proporciona
Coeficientes de Prdida de Carga en la Entrada (Ke) basados en la
informacin disponible para materiales tpicos de tuberas y tipos de
terminacin o bordes. En ltima instancia, es el ingeniero de diseo quien
deber determinar el valor ms adecuado para el Coeficiente de Prdida
de Carga en la Entrada para una aplicacin particular.
Manual de Ingeniera ADS HIDRULICA 3-14
ADS, Diciembre 2010
Tabla 3-3
Coeficientes de Prdida de Carga en la Entrada
(
*
,
**
)
(Control de salida, flujo parcial o a tubo lleno)
Tipo de Estructura y Diseo de la Terminacin del Extremo Ke
Tubera Concreto*
Prolongado fuera del terrapln, extremo corte recto 0,5
Corte recto con muro de cabecera 0,5
Chaflanado para ajustarse a la pendiente del relleno 0,7
Bordes biselados, biseles de 33,7 0,2
Tubera Metal Corrugado*, Polietileno ADS**
Prolongado fuera del terrapln, sin muro de cabecera 0,9
Corte recto con muro de cabecera 0,5
Chaflanado para ajustarse a la pendiente del relleno (talud) 0,7
Seccin terminal prefabricada para ajustarse a la pendiente del talud 0,5
Bordes biselados (bisel de 33,7 o 45) 0,2
Con muro de cabecera perpendicular al eje del tubo con o sin muros de
ala y aristas biseladas.
0,2***
*) Informacin obtenida del Departamento de Transporte de la Administracin Federal de Carreteras de
Estados Unidos: Diagramas Hidrulicos para la Seleccin de Alcantarillas para Carreteras
5

**) Se estima que las tuberas Tigre-ADS tienen coeficientes similares a aquellos determinados para
tuberas de metal corrugado.
***) Valor asignado para Metal Corrugado en el Manual de Carreteras del Ministerio de Obras Pblicas de
Chile
3-9 EJEMPLOS
Los siguientes ejemplos de problemas muestran el uso de los factores
de conduccin en el dimensionamiento de tuberas, chequeos bsicos
de velocidad y opciones de diseos.
Ejemplo 1
Dado: Las condiciones de terreno requieren una capacidad de las
tuberas de 2 pies cbicos por segundo (2 ft
3
/s) y una pendiente del
0,5%.
Encontrar: El tubo ADS que proporcione la solucin hidrulica
ptima.
Solucin: Es necesario utilizar la Ecuacin 3-4 para determinar el
factor de conduccin necesario para las condiciones dadas. Antes de
sustituir los valores en la ecuacin, en primer lugar se debe convertir la
inclinacin en un valor con unidades de pies/pie, de la siguiente
manera:
0,5% = 0,005 ft/ft
Manual de Ingeniera ADS HIDRULICA 3-15
ADS, Diciembre 2010
Luego, sustituir los valores directamente en la ecuacin 3-4.
Consulte la Tabla 3-2a para seleccionar el producto de tubera
adecuado, con un coeficiente de conduccin mnimo de 28.3, segn el
valor n de Manning correspondiente. Las soluciones ms prcticas
son las siguientes:
Tubera corrugada de interior liso (N-12), 12 pulgadas k = 38,6
Tubera de pared simple (SW), 15 pulgadas k = 38,2
La solucin ptima sera la tubera con el factor de conduccin ms
cercano al calculado. Tanto la tubera de doble pared, corrugada
exterior e interior liso, de 12 pulgadas, como la de pared simple de 15
pulgadas casi igual porque sus factores de conduccin se acercan
mucho al requerido. La seleccin final del tipo y tamao de la tubera
se analiza en el Ejemplo 2.
Ejemplo 2
Sustituyendo los datos de las soluciones tentativas seleccionadas en
el Ejemplo 1, en la frmula de velocidad (Ecuacin 3-5), el flujo en la
tubera de 12 pulgadas (corrugada exterior e interior liso) alcanzar
una velocidad de 3,5 pies por segundo (ft/s) y la tubera de pared
simple de 15 pulgadas, una velocidad de 2,2 pies por segundo (ft/s).
Por lo tanto, se debe seleccionar la tubera de 12 pulgadas con el fin
de lograr la velocidad mnima de auto-limpieza.
Ejemplo 3
Dado: Las condiciones de terreno requieren una capacidad de la
tubera de 2 pies cbicos por segundo (2 ft
3
/s) y una pendiente del
0,5%.
Encontrar: El tubo ADS que proporcione la solucin hidrulica
ptima.
Solucin: Es necesario utilizar las Figuras 3-1 y 3-2 para determinar
las tuberas disponibles.
0,5% = 0,005 ft/ft
Manual de Ingeniera ADS HIDRULICA 3-16
ADS, Diciembre 2010
Consulte la Figura 3-1 para seleccionar el dimetro de la tubera
corrugada de interior liso (Tubera ADS N-12). La interseccin de las
lneas de 0,5% y 2 pies cbicos por segundo (2 ft
3
/s) est por encima
de 10", pero por debajo de 12". Por lo tanto, las tuberas de 12
pulgadas N-12 (doble pared, corrugadas de interior liso) son
aceptables.
Consulte la Figura 3-2 para seleccionar el dimetro de una tubera
corrugada pared simple (SW). La interseccin de las lneas de 0,5% y
2 pies cbicos por segundo (2 ft
3
/s) est por encima de 12", pero por
debajo de 15". Por lo tanto, las tuberas de 15" pared simple pueden
ser utilizadas.
La solucin ptima sera la tubera con la capacidad de flujo por lo
menos tan grande como la requerida. La tubera de 12 pulgadas
(corrugada, de interior suave) y la de 15 funcionarn casi de la misma
manera, porque sus capacidades de flujo son mayores que la
requerida. La seleccin final del tipo y tamao de la tubera se realiza
en el Ejemplo 4.
Ejemplo 4
Sustituyendo en las figuras 3-1 y 3-2 la informacin de las soluciones
tentativas seleccionadas, la tubera de 12 pulgadas (doble pared,
corrugada de interior liso) y la tubera de 15 pulgadas de pared simple
producirn velocidades de aproximadamente 3,6 y 2,8 pies por
segundo (ft/s) respectivamente. Por lo tanto, se debe seleccionar la
tubera de 12 pulgadas para contar con una velocidad mnima de auto-
limpieza.
3-10 REFERENCIAS
1
Federal Highway Administration, Hydraulic Design of Highway Culverts
(HDS 5), 2
nd
Edition , 2001, Pg. 33.
2
Federal Highway Administration, Design Charts for Open-Channel
Flow (HDS 3), August 1961, Chapter 5.
3
Clyde, Calvin G., Manning Friction Coefficient Testing of 4-, 10-, 12- and
15-inch Corrugated Plastic Pipe. Utah Water Research Laboratory, Report
No. 36, May 1980.
4
Lingedburg, Michael P.E. Civil Engineer Reference Manual. Belmont,
CA: Professional Publications, Inc.
5
Federal Highway Administration, Design Charts of Highway Culverts
(HDS 5), 2nd Edition, 2001, Pg. 223.