Please read and follow the installation and operating instructions carefully to ensure safe and trouble free
appliance operation.
Kospel S.A. may make minor changes if necessary in the appliance that will not be shown in the operating
instruction, so long as the main features of the unit remain the same.
Used product can't be treated as general communal waste. Disassembled appliance has to be delivered
to the collection point of electrical and electronic equipment for recycling. Appropriate utilisation of used
product prevents potential negative environmental influences that may occur as a result of inappropriate
handling of waste.
In order to get more detailed information about recycling this product you should contact the local govern-
ment unit, waste management service or the shop where this product has been purchased.
3
GB-016B_p.487
Contents
Introduction 4
Installer instruction manual
Technical data 5
Construction 6
Installing the boiler 8
Connection of external appliances 11
Startup 13
User instruction manual
Operating 13
Failures 16
Storing 17
Boiler kit 17
4
In order to install and operate the boiler properly, study this manual thoroughly. A long life and faultless per-
formance of this appliance depends mainly on its proper installation and operation.
EKCO.L1z / EKCO.L1Nz is suitable for central heating system that use the water or antifreeze solution as the
medium carrying heat. A power of boiler should be matched with heat loss of a given building.
Power of boiler / An approximate heating area:
4 kW 30 50 m
2
6 kW 40 70 m
2
8 kW 60 100 m
2
12 kW 100 140 m
2
15 kW 130 180 m
2
18 kW 150 220 m
2
21 kW 180 250 m
2
24 kW 220 300 m
2
30 kW 225 375 m
2
36 kW 270 450 m
2
While calculating demand for thermal energy, a number of factors needs to be taken into consideration:
- building cubature
- value of heat transfer through the walls, windows and ceilings
- level of room ventilation
- heat accumulation
The EKCO.L1z / EKCO.L1Nz is a low temperature boiler intended for unvented or vented central heating sys-
tems with forced circulation (protected according to legally binding norms). The boiler features automatic work
control and low maintenance requirements.
The boiler is equipped with following safety devices:
- a system of flow control,
- an inner temperature controller,
- a safety temperature limiter,
- a relief valve.
and the following accessories: circulation pump, expansion vessel (EKCO.L1Nz model only), automatic vent
valve.
A boiler and the necessary
installations should be carried
out by professional.
Introduction
5
GB-016B_p.487
Technical data
5
GB-016B_p.487
Installer instruction manual
Max. pressure MPa 0,3
Min. pressure MPa 0,05
Out flowing water temp. C 40 85
Max. water temp. C 100
Overall dimensions (height x width x depth) mm EKCO.L1z 660 x 380 x 175 EKCO.L1Nz 700 x 425 x 285
Weight kg EKCO.L1z ~16 EKCO.L1Nz ~24
Water connection G 3/4"
Expansion vessel l 6
Safety class IP 21
Rated power consumption kW 4 6 8 4 6 8
Rated voltage 230V~ 400V 3N~
Rated current A 17,4 26,0 34,8 3 x 5,7 3 x 8,7 3 x 11,7
Fuse rated current A 20 32 40 10 16
Min. connecting wires section mm
2
3x2,5 3x4 3x6 5x1 5x1,5
Max. connecting wires section mm
2
5 x 16
Max. allowed network impedance 0,44 0,39 0,34
Rated power consumption kW 12 15 18 21 24 30 36
Rated voltage 400V 3N~
Rated current A 3x17,3 3x21,7 3x26,0 3x30,3 3x34,6 3x43,3 3x52,0
Fuse rated current A 20 25 32 40 50 63
Min. connecting wires section mm
2
5 x 2,5 5 x 4 5 x 6 5 x 10
Max. connecting wires section
mm
2
5 x 16
Max. allowed network impedance 0,14 0,09
6
The boiler EKCO.L1z consists of,
among others, the following main
parts:
- a heating box [1], heating ele-
ments heat circulating water
- a control board [12]
- a circulating pump [5] that forces
water to flow
There are safety devices that pro-
tect the boiler from failures and
destruction:
- a safety temperature limiter [6], if
the temperature of water reaches
100
0
C the device cuts off the
power supply, and the boiler will
not operate
- a flow sensor [2], it will not allow
the boiler to start heating before
it reaches the right flow
- a safety valve [4], it is on if the
pressure in the central heating
system goes over the pressure
limit [3bar]

Fig.1 Construction of EKCO.L1z
[1] - heating box
[2] - flow sensor
[3] - manometer
[4] - safety valve
[5] - circulating pump
[6] - safety temperature limiter
[7] - water inlet
[8] - water outlet
[9] - ZIO board
[10] - power board
[11] - automatic vent
[12] - control board
PF - connection points of phases con-
ductors
PN - connection points of protective and
neutral conductor
WP - electric cable-bush
M - points of fixing the boiler
RP - point of the room thermostat con-
nection
1
Construction
6
Installer instruction manual
7
GB-016B_p.487
2
Fig.2 Construction of EKCO.L1Nz
[1] - heating box
[2] - flow sensor
[3] - manometer
[4] - safety valve
[5] - circulating pump
[6] - safety temperature limiter
[7] - water inlet
[8] - water outlet
[9] - ZIO board
[10] - power board
[11] - automatic vent
[12] - control board
[13] - expansion vessel and connection
PF - connection points of phases con-
ductors
PN - connection points of protective and
neutral conductor
WP - electric cable-bush
M - points of fixing the boiler
RP - point of the room thermostat con-
nection
7
GB-016B_p.487
Installer instruction manual
8
- a wet central heating system must be flushed out before boiler installation;
- do not install any barrier fittings (e.g. valves) on the outlet of the safety valve [4] (fig.1, 2);
- this appliance must not be installed in a humid place or in a place exposed to the danger of explosion;
- this appliance must be protected by filter with magnetic insert (included in the boiler kit).
Conditions of installation
- appropriate power supplies;
- an efficient electrical installation
which has been completed in ac-
cordance with the binding norms
of electric installation;
- a wet central heating system
equipped with appropriate ex-
pansion vessel made according
to binding norms for closed or
open systems.
- a wet central heating system
made according to standards,
equipped with appropriate ex-
pansion vessel:
All installation works have to be
carried out with water and power
supplies shut off.
Fig.3 Central heating installation
diagram
PI - manometer
ZK - cut-off valve
F - magnetic filter
RW - expansion pipe
NW - expansion vessel
ZT - thermostatic valve
ZP - passage valve
G - radiator
RTP - room programmed thermostat
ZU - differential pressure relief valve
A boiler with a hot water cylinder
ZTD - three-way valve
ZAS - hot water cylinder
TZ - WE-008 sensor or cylinder thermo-
stat
3
The EKCO.L1N is equipped with an expansion vessel (capacity: 6l, pressure: 1,5 bar). The expansion vessel is
sufficient against the following capacities of the heating system at given temperatures of the medium and central
heating system pressure.
Installing the boiler
8
Installer instruction manual
Its recommended for electric instal-
lation with thermostatic radiator
valves to apply the differential
pressure relief valve. It allows the
system to keep minimal flow of
medium through the boiler and
reduce noises in installation during
the thermostatic valves closing. The
valve must be installed in bypass
conduit (before the boiler) accord-
ing to manufacturers instruction.
A magnetic filter must be installed on return pipe of central heating installation system
(before boiler inlet). The filter must be installed in horizontal position, accordingly to flow
direction (see arrow on the filter body), with the magnetic insert chamber to the bottom.
Shall the capacity of the wet central heating installation be larger, an extra expansion vessel should be installed on it.
9
GB-016B_p.487
Inlet Outlet
Fig.4 Installation of the boiler on
a wall
a - EKCO.L1z
b - EKCO.L1Nz
4b
Inlet Outlet
4a
Installation
1. Hang the boiler up in a vertical position on fixing screws with inlet and outlet pipes to the bottom, maintain-
ing clearances from the walls and the ceiling (fig.4).
2. Connect the boiler to a central heating system equipped with cut-off valves (fig.3).
3. Fill the central heating system with a treated water that substantially extends the life of the heating elements.
9
GB-016B_p.487 Installer instruction manual
While applying ther-
mostat make sure there is no
voltage on its entry!
Do not connect any voltage
into RP, NA, WZ inlets! This can
result in permanent ZIO module
damage.

!
Temperature of heating medium (feed
and return)
Capacity of central heating system Pressure in central heating system
[C] [l] [bar]
85/70 58
1,5
70/55 79
55/45 103
50/40 115
45/35 128
10
El ectri c i nstal l ati on
should be equipped with resid-
ual current protective devices
and other solutions which will
ensure disconnecting the heater
from the source of power (in-
tervals between all their poles
should not be less than 3 mm).
Fig.5 Connection to electric
mains

!
10
Installer instruction manual
5
4. Vent the wet central heating sys-
tem.
5. Connect a boiler to the electrical
system (fig.5, 1 or 2).
6. Fix the room thermostat, in ac-
cordance with manual instruc-
tion.
7. Connect the room thermostat (by
using two wires 2 x 0,35 mm
2
)
to the ZIO terminal (RP entry) as
shown in fig 7a.
8. Once you have finished the
above procedures, you can start
the boiler according to start-up
section (page 13).
6a 6b
Fig.6a Connection to the three
phase system.
PNL - points of neutral and protective
conductor connection
PF - points of phase conductors connec-
tion
[6] - temperature limiter
Fig.6b Connection to the single
phase system (for boilers
of 4kW,6kW and 8kW)
PNL - connection points of neutral, pro-
tective and phase conductors
[6] - temperature limiter
[15] - additional conductors (for single
phase system only)
N
L
N
L
Attention: 4, 6 and 8kW boilers
are factory preset to work as
single phase boilers [figure 5b].
If you intend to connect the
boiler to a three-phase installa-
tion, take off the [15] wire set.
11
GB-016B_p.487
Room thermostat (RP entry) -
when the voltage free contact gets
opened the boiler will stop heating.
The entry is responsible for boiler
control depending on the room tem-
perature. It is described in section
INSTALLATION, (page 10).
WE-008 Cylinder water tempera-
ture sensor (Tzas entry) please,
refer to fig. 7 to see how to connect
it to the boiler. Attention, make sure
that the white wire is + and the yel-
low wire is -. It will not work if you
connect it the other way round. If it is
necessary, you can extend the wires,
however, please remember that the
shorter the wires the better. If the wire
Connection of external
appliances
Fig.8 Cooperation of master boiler
with EKCO boiler
KN - master boiler
PI - manometer
F - filter
RW - expansion pipe
NW - expansion vessel
ZT - thermostatic valve
ZP - passage valve
G - radiator
RP - room programmed thermostat
ZTD - three-way valve
ZAS - cylinder
TZ - cylinder thermostat or domestic hot
water sensor
ZZ - non-return valve
7
Fig.7, 7a ZIO board
ZTD - three-way valve with actuator
ZAS - connection point of three-way
valve
Tzas - connection point of water temp.
sensor (in cylinder)
WE - 008 KOSPEL - water temp. sensor
(in cylinder)
C - cylinder thermostat
A - room thermostate Auraton 2005
(see fig.7a)
B - master appliance
WZ - connection point of cylinder ther-
mostat
RP - room thermostat connection point
NA - master appliance connection point
MR - radio module connection point
8
RP, WZ, NA dead-voltage entries. Do not connect any voltage circuit!
11
GB-016B_p.487
Installer instruction manual
7a
w
h
i
t
e
y
e
l
l
o
w
black
brown
blue
room thermostate
Auraton 2005
12
is too long there may occur disturbances and it may not work properly. The wires should not run close to mains
cables, they must not go around other electric wires.
Cylinder thermostat (Tzas entry) a voltage free entry. When the Tzas entry is closed, the boiler will switch
over to heat the cylinder.
Three-way valve control (ZAS) Kospel SA suggests using VCZMH600E valve manufactured by Honeywell with
a motor operator VC6012ZZ00 and a wire 45900445-013B. The three-way valve control is performed by applying
230V on the brown wire or the black wire (blue is the neutral wire). Voltage on the valve through the brown wire
will switch the valve to a position, where the pass between the AB inlet and the B outlet gets opened. Shall
voltage be passed to the black wire, the valve will get switched to a position in which the channel between the
AB inlet and the A outlet will be opened. The AB inlet and the A and B outlets are marked on the valve.
The entry A is to supply the central heating system and the entry B is to supply the cylinder as shown in fig.7
Master appliance (NA entry) you can limit the power used, i.e. the boiler can be switched off while another
appliance consumes electricity. To do it, an electrician should install in line an extra open contact in to the NA
entry (voltage free entry), so that when a master appliance gets on, the contact will be opened the boiler switched
off. When the NA contact gets opened, heating will get off and the pump stopped. The EKCO boiler may also work
as the second boiler. If it is so, the master boiler by opening the NA entry will stop heating of EKCO. However,
the mode of the three-way valve control stays on so a cylinder is charged by the heat from the master boiler.
Radio module MR there is also an option of a room thermostat that can control the boiler with a radio
signal. If this is your wish, you should install a radio module (receiver) as shown in figure 7. Next, take the aerial
out through the opening at the back of the boiler cover. After the module is installed, make sure that it works by
observing two (2) control lamps on the receiving module:
a) insert batteries into the transmitter (sender) and allow 5 minutes for synchronizing with the receiver,
b) make sure that the transmitter is within the radius of 20 m from the receiver,
c) observe the green control lamp that informs about receiving the signal, it is on for 1s at 1 minute intervals.
Incorrect work of the radio system may be caused by the following reasons:
a) too long a distance between the transmitter an the receiver, it works up to 20 m in horizontal distance and
within adjacent floors vertically,
b) batteries are not charged up,
c) improperly installed aerial, for example within the boiler,
d) damaged aerial wire.
12
Installer instruction manual
13
GB-016B_p.487
1. Disconnect the NA contacts (fig.7)
2. Set the pump on manual mode.
3. Switch the boiler on (press button)
4. Make sure that a proper flow through the boiler is reached (the "B" indicator
is on with a constant light, see fig.11). The pump should get vented itself
after a short working time, however, if necessary, vent the pump in the
following way:
close the cut-off valve on the outlet
set the pump on the highest gear (fig.9)
undo carefully the vent plug (fig.10) on the pump
after 15-30 s. do the vent plug up
open the cut off plug
5. Switch the boiler off (hold the button for 2 seconds)
6. Connect NA contact
7. Set the pump on automatic mode
8. Switch the boiler on ( button, fig.11).
9. Set the temperature of the medium at required temperature, see Operat-
ing section.
9
10
Fig.9 Setting the pump on the high-
est gear
Fig.10 Pump venting
Startup
Fig.11 Front control panel
A - cylinder indicator
B - pump and flow indicator
C - heating on and room thermostat indi-
cator
D - inlet temperature indicator
E - outlet temperature indicator
F - medium temperature setting indicator
G, H, I - measurement value indicators
J - LCD display
K - temperature of water in the cylinder
indicator
L - switches
Recommendations
We recommend the following routine maintenance in order to assure
faultless operation:
1. Do not drain the water from central heating system after the heating
season.
2. Get rid of any effluent from the central heating system and boiler
connection points.
3. Leave the controller in stand-by mode and do not cut off power supply
between the heating seasons.
4. Contact with authorised serviceman for an inspection before every
heating season.
11
Operating
User instruction manual
14
Control panel operation
The control panel consists of two working areas: the signalling area (elements: A-K) and control area (L). The
user can select three operating modes: stand-by, winter (central heating or central heating + cylinder heating),
summer (cylinder heating).
Stand-by mode
To set the stand-by mode press and hold for 2 seconds. Note: Do not cut power supply off between heat-
ing season. When the control panel is switched to stand-by mode all indicators are off. In this mode the boiler
is off but the pump is activated every day for 15 minutes (what protects the boiler and the whole central heating
installation from being blocked and silted up). The pump will run every day at the same time, it will be the time
of the day when you switch it to the stand-by mode e.g., if you set the pump on a stand-by mode at 6 p.m.
the timer will activate the pump everyday for 15 minutes starting at around 6 p.m.
Winter mode
If you press the , button , the winter mode will be set ( when you set from stand-by to winter mode).
The medium temperature setting will appear on the LCD display. Raise and lower the temperature by pressing
buttons The temperature setting range: 40
0
to 85
0
C.
In order to ensure smooth and economic working, the temperature of the medium has to be set in accordance
with current weather conditions (outdoor temperature), taking into account parameters of the heated building (e.g.
its compactness, insulation, windowing etc.). Exemplary characteristics are shown on fig.12. Optimum settings
of the medium temperature limit running costs of the boiler.
In the winter mode (central heating + hot water cylinder heating) the three-way valve directs the water(medium)
to central heating installation or hot water cylinder coil. The priority is to heat the hot water cylinder at the same
time the central heating system is off.
If the WE-008 sensor for temperature measurement in hot water cylinder is applied (connected to the Tzas entry
on the ZIO board) pressing the button switches the controller for water temp. setting in the hot water cylinder
(indicator K is lighted). The medium temperature setting for hot water cylinder will appear on the LCD display
(J). Raise and lower the temperature by pressing .
If the thermostat for temperature measurement in hot water cylinder is applied (connected to the Tzas entry on
the ZIO board) , the temperature setting on front panel is not available. Setting is performed directly on the hot
water cylinder thermostat.
Be aware that the working parameters show approximate value only. Next pressing of let you return to
medium temp. setting mode for central heating system. Pressing of or (when you checking the parameters)
let you return to medium temp. setting for central heating system.
A B and C indicators informs about the heating stages:
User instruction manual
The boiler is preset by factory
to co-operate with a central
heating system.
The advanced settings enable
you to set the boiler to co-op-
erate with a hot water cylinder.
15
GB-016B_p.487
Indicator A is on the boiler co-operates with the hot water cylinder.
Indicator B is on - indicator informs that the pump is working
and there is a proper flow through the boiler. If the indicator flickers, it
means that there is a not sufficient flow rate or there is no flow rate at
all. It is an alarm state, which prevents the boiler from heating.
Indicator C - when green light is on the settled temperature has
been achieved
Indicator C when red light is on the boiler is operating
Indicator C - when light is off room thermostat temperature has been
achieved, the room thermostat switches the heating off.
Summer mode
If you short press the button , the summer mode will be set ( when
you set from winter to summer mode). In this mode the three-way valve
12
directs the water (medium) to the coil inside the hot water cylinder only. The summer mode should be used
after the heating season.
If the WE-008 sensor for temperature measurement in hot water cylinder is applied ( connected to the Tzas
entry on the ZIO board) pressing the button allows to set temperature.
If the thermostat for temperature measurement in hot water cylinder is applied (connected to the WZ entry on
the ZIO board) , the temperature setting on front panel is not available ( the panel shows --). Setting is performed
directly on the hot water cylinder thermostat.
In this mode the button is inactive. Checking the inlet and outlet water temp., flow rate and power is not
available. To switch to winter mode press .
Fig.12 Dependance between me-
dium temperature and the
outdoor temperature (at
20C room temperature)
User instruction manual
16
Symptom Reason Action
The indicators on the front panel
are off
No power supply
Check parameters of the power mains and fuses
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The B indicator flickering
Pump blocked
Unblock the pump by undoing a screw on the
pump casing by mechanical turning of the
shaft of the rotor
Water does not circulate through the boiler - the
boiler is blocked
Too much air in the central heating system - vent
the system, the pump and the boiler
Check patency of the central heating system,
clean the filter
A failure of pumps power supply
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
A failure of the pump or flow sensor
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The C indicator does not light, the
room thermostat signals switching on
of the boiler
A failure of the electric installation connecting the
room thermostat
Check the room thermostats connecting instal-
lation
A failure of electronic module
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The D indicator flickering
A failure of inlet water sensor, the boiler oper-
ates at emergency mode
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The E indicator flickering A failure of outlet water sensor, heating is blocked
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The C indicator flickering and
master appliance does not work
A failure of the electric installation connecting the
master appliance
Check the electric installation connection
A failure of electronic module
Call an authorized service or if not available in
your area, contact serwis@kospel.pl
The boiler does not heat up the
cylinder
A failure of cylinder temperature sensor
or room thermostate
Call an authorized service or if not available
in your area contact serwis@kospel.pl, replace
temperature sensor or room thermostate
A failure of three-way valve servo Replace servo
A failure of electronic module
Call an authorized service or if not available
in your area contact serwis@kospel.pl
Failures
In case, the boiler does not work properly after the above checks and none of the failures is present, contact
an authorised service.
User instruction manual
17
GB-016B_p.487
Keep the boiler in a dry place with a temperature between 5 and 35
0
C.
EKCO.L1z/ EKCO.L1Nz boiler 1 piece
Fixing screws 2 pieces
Magnetic filter for central heating system F-MAG 3/4" 1 piece
Storing
Boiler kit
This appliance is not intended
for use by persons (including
children) with reduced physical,
sensory or mental capabilities or
lack of experience and knowl-
edge, unless they have been
given supervision or instruction
concerning use of the appliance
by a person responsible for their
safety.
Children should be supervised
to ensure that they do not play
with the appliance.