For Closed Conduits
r
i
t
t
m
e
y
e
r

EXTENSIVE EXPERIENCE IN
FLOW MEASUREMENT
ACCURATE AND RELIABLE FLOWMETER
The intrinsic accuracy of the flowmeter is the first
condition to meet customer demands for overall
measurement accuracy.
Air bubbles and suspended solids often cause pro-
blems in signal detection. A state of the art signal
detection method is therefore necessary to avoid
such problems.
C
O
N
D
I
T
I
O
N
S
T
O

A
C
H
I
E
V
E
A
C
C
U
R
A
T
E
F
L
O
W

M
E
A
S
U
R
E
M
E
N
T
:
KNOWLEDGE OF HYDRAULIC
CONDITIONS
Not every location along the pipe is suitable for flow
measurement. Hydraulic flow conditions affect flow
measurement to a large extend. Therefore the measu-
ring site has to be selected carefully.
PRECISE DETERMINATION OF PIPE
GEOMETRY AND TRANSDUCER
POSITIONS
Measurement accuracy is largely influenced by the
geometric variables of the measuring point such as the
cross-section of the pipe and the exact positions of
the transducers.
For that reason determination of those variables as
well as precise installation of transducers is of major
importance.
RISONIC 2000 FLOWMETER
RISONIC 2000 uses very high resolution multipath
transit time measurement and the latest digital proces-
sing technology (DSP) to achieve first class measuring
accuracy.
Transducers cause distortion to the fluid flow if they
protrude into the conduit. RISONIC 2000 compensates
this effect by means of flow computation based on the
type of transducer used.
Advanced signal analysis (cross-correlation) enables
correct signal detection and improves measurement
reliability, even in the presence of considerable amounts
of suspended solids.
PRE-INSTALLATION
Rittmeyer provides services to support customers in
determining:
The best location for flow measurement
The optimum orientation and arrangement of the
measurement paths
The range of service extends from recommendations
up to extensive engineering.
INSTALLATION SERVICES
Rittmeyer provides both the tools for customer
installation as well as installation carried out by our
own experienced staff for the highest accuracy
demands.
F
R
O
M

S
I
M
P
L
E

L
O
W
-
E
N
D
T
O
S
O
P
H
I
S
T
I
C
A
T
E
D

H
I
G
H
-
E
N
D
F
L
O
W

M
E
A
S
U
R
E
M
E
N
T
:
R
I
T
T
M
E
Y
E
R

P
R
O
V
I
D
E
S
C
O
M
P
L
E
T
E

S
O
L
U
T
I
O
N
S
INSTALLATION
SERVICES
Hydraulic flow conditions have to be considered in order
to achieve the best measurement performance. Optimum
selection of measuring site and path arrangement are
prerequisites for successful flow measurement.
SIMPLE FLUID FLOW CONDITIONS
When the flow is free of turbulence as is
the case with long straight runs, a single
path arrangement is ideal.
SELECTION OF MEASURING SITE
Based on the building plans of your facility,
our engineering group provides suggestions
for the best measurement location. For
critical applications, computerised velocity
profile simulations are performed to
support selection.
SELECTION OF PATH ORIENTATION
AND ARRANGEMENT
Depending on the actual hydraulic flow conditions, our
engineering team selects optimum orientation and
arrangement for the measuring paths.
DIFFICULT HYDRAULIC FLOW
CONDITIONS
If there are any cones, necks, elbows, vanes
or pumps adjacent to the planned location
for flow measurement a disturbed flow
distribution is to be expected. To meet accu-
racy requirements under these conditions
optimum path orientation and arrangement
are indispensable.
Single path arrangement Multipath
arrangement
Multipath arrangement
with crossed paths
ENGINEERING
Careful installation of transducers at theoretically defi-
ned positions, precise determination of pipe cross-sec-
tion and determination of final positions of installed
transducers are the key to first class measurement
accuracy.
CUSTOMER TRANSDUCER
INSTALLATION
For customer installation of transdu-
cers, Rittmeyer offers a wide range of
different marking and installation tools.
Please refer to the recommendations
on installation methods and tools
overleaf.
PIPE GEOMETRY COMPENSATION
Rittmeyer apply OWICS (Optimal Weighted
Integration for Circular Sections) developed
by the Swiss Federal Institute of Techno-
logy, to compensate for pipe geometry
deviations.
HIGH PRECISION INSTALLATION
For highest possible accuracy demands,
Rittmeyer recommends high precision
installation by our experienced staff using a
theodolite with integrated interferometer
for distance measurement and laser poin-
ter accessory.
Installation Services
Determination of pipe cross-section
Installation of transducers
Determination of final positions of
installed transducers for use in flow
computation
Configuration of flowmeter
Levelling Set
m
ax. 300 m
RISONIC 2000 TRANSIT TIME
FLOWMETER OF THE LATEST GENERATION
MULTIPLE PIPE MEASUREMENT
SINGLE AND MULTIPATH
MEASUREMENT
From single to highly sophisticated
8-path flow measurement
Different path arrangements including
4 and 8-path measurements according
to IEC 41 (ASME PTC 18)
PIPE DIAMETERS
From 250 to 14 000 mm (10 to 550)
Wide range of transducers
EASY-TO-USE FLOWMETER
User friendly configuration and operation
by means of:
Integrated user interface
- large illuminated LC display
- pull-down menu
- alphanumeric keyboard
- cursors
RS-232 interface together with remote
configuration software for use with PC
and/or Laptop
APPLICATIONS
Hydroelectric power
Water supply
Irrigation
Drainage
Water cooling systems
ADVANTAGES
of multipath transit time
technology are:
High accuracy
Suitable for difficult hydraulic
conditions
No head loss through metering
section
Bi-directional flow
Reverse flow calculation
No re-calibration required
Independent of liquid conductivi-
ty and temperature
High reliability and repeatability
No moving parts
- no maintenance required
1E1P
1E2P
1E4P 2E8P
2E4P
2E2P
Accuracy up to 0.5% of reading
(depending on hydraulic flow conditions and accuracy of geometric variables of measuring site)
Number of ultrasonic paths single to 8 paths in a variety of path arrangements
including IEC 41( ASME PTC 18) for 4 and 8 paths
Number of pipes 1 to 4
Pipe diameters 250 to 14000 mm (10 to 550)
Range of velocity 20 m/s (65 ft/s)
Distance electronics to transducers max. 300 m (980 ft)
Interfaces 1 analog output: 4 - 20 mA
4 relays: OK, forward/backward indication, 2 relays for impulse or limit output
RS-232: for remote configuration by PC and/or Laptop
Optional interfaces max. 4 slots for following interface modules:
- analog output module: 2 outputs 4 - 20 mA
- relay module: 3 relay outputs with isolated change-over contacts:
AC: 8 A / 250 V max. 2000 VA
DC: 8 A / 250 V max. 50 W
Power requirements 115/230 VAC / 45 - 65 Hz
24 - 48 VDC
Power dissipation AC 50 VA / DC 35 W
Overvoltage protection built-in
Enclosure protection IP 65 (NEMA 4)
Enclosure dimensions (h, w, d) 400 x 300 x 210 mm (15.7 x 11.8 x 8.3)
Weight 12 kg (26.5 lb)
Pipe Diameter Path Arrangements Installation by
1E1P, 2E2P
Customer*
250 to 1000 mm 1E2P, 2E4P
(10 to 40) 1E4P Surveyor or
2E8P Rittmeyer
1E1P, 2E2P
Customer*
1000 to 2500 mm 1E2P, 2E4P
(40 to 100) 1E4P Surveyor or
2E8P Rittmeyer
>2500 mm
any
Surveyor or
(>100) Rittmeyer
This product concurs with the authoritative terms of the EU and it is marked with the CE-label.
TECHNICAL DATA
* for installation accessories please request data sheets
For further information please request brochures for our closed conduit transducers.
INSTALLATION METHODS AND TOOLS
TRANSDUCERS
Path Arrangements
Certified
Quality System
ISO 9001