Vous êtes sur la page 1sur 67

Appendix: 1

Service Item Descriptions


Mobily_Swap_Implementation





Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 2 of 67
Issue 2013-02-08 printed: December 11, 2013


Table of Contents
1. Implementation (Generals) ................................................................................ 5
2. 00033403 C antenna line (For complete Feeders Per site) ............................ 6
3. 00038272 I 7-8 antenna line basic (1 run up-to any length) ........................... 7
4. 00038304 I Flexi BS RF modules ...................................................................... 8
5. 00047199 I Flexi BS system module ................................................................ 9
6. 00001357 I panel antenna up to 3m ............................................................... 10
7. 00038290 IC FO cable basic............................................................................ 11
8. 00001382 IC IP hub type device ..................................................................... 12
9. 00038297 IC LAN cable basic ......................................................................... 13
10. 00045202 IC remote RF module feed basic (Per site) ................................... 14
11. 00039294 InstM Flexi BS ................................................................................. 15
12. 00073261 BTS INST. MATERIALS .................................................................. 16
13. 00007502 M LAN cable basic .......................................................................... 17
14. 00045205 M remote RF module feed add (2x5m) .......................................... 18
15. 00045204 M remote RF module feed basic (2x20m) ..................................... 19
16. 00038731 M singlemode FO cable basic ....................................................... 20
17. 00000890 Multiple travel ................................................................................. 21
18. 00056303 On site BS integration .................................................................... 22
19. 00001513 Rem BTS/BSC/TCSM modules ...................................................... 23
20. 00001485 Site survey BS site ......................................................................... 24
21. 00001487 Transport DOP/Site to Site 0-3,5t regulr ....................................... 25
22. 00001344 I BSC ................................................................................................. 26
23. 00001383 IC lamp panel ................................................................................... 28
24. 00001390 I MHA-TMA ....................................................................................... 29
25. 00001413 ICIntg PIU ext ................................................................................... 30

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 3 of 67
Issue 2013-02-08 printed: December 11, 2013


26. 00001515 Rem proprietary PCM ...................................................................... 31
27. 00001516 Rem subrack server or IP hub device ............................................ 32
28. 00003379 I blade server chassis ..................................................................... 33
29. 00003934 Site survey core ............................................................................... 34
30. 00003957 Rem cabinet BSC-RNC .................................................................... 35
31. 00033865 Travel low ......................................................................................... 37
32. 00033872 Travel TRS ........................................................................................ 38
33. 00033875 Rem cabinet BSC-RNC add ............................................................ 39
34. 00038266 I 1 5-8 antenna line basic (1 run upto any length) ........................ 41
35. 00038268 I RDSA Cables (For Diversity Sharing) .......................................... 42
36. 00038285 I floor mount 19-23 cab ................................................................... 43
37. 00038559 InstM BSC ........................................................................................ 44
38. 00038637 InstM packaging for cables ............................................................ 46
39. 00038638 InstM packaging for PIUs ................................................................ 47
40. 00038640 InstM packaging for cabinet ........................................................... 48
41. 00039295 I indoor Flexi BS cab ....................................................................... 49
42. 00040307 I ODF block or module .................................................................... 50
43. 00040308 M ODF block (48 ports) ................................................................... 51
44. 00038565 InstM TCSM ...................................................................................... 52
45. 00001361 I TCSM .............................................................................................. 53
46. 00073251 Implementation BTS 2G and UMTS900 for swap .......................... 54
47. 00073252 BTS Implementation TDD LTE for Swap sites .............................. 56
48. 00001347 I diplexer ........................................................................................... 58
49. 00001504 Rem MHA-TMA ................................................................................ 59
50. 00001509 Rem omni or panel antenna up to 2m ............................................ 60
51. 00007508 M floor mount 19-23 open frame .................................................... 61

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 4 of 67
Issue 2013-02-08 printed: December 11, 2013


52. 00038286 I floor mount 19-23 open frame ...................................................... 63
53. 00007509 M floor mount 19-23 cab ................................................................. 64
54. 00073254 Implementation BTS Modules Re-arrangement ............................ 66
55. 00073255 BTS Modules Removal and Installation ......................................... 67


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 5 of 67
Issue 2013-02-08 printed: December 11, 2013


1. Implementation (Generals)

Includes
These activities are included for every service item:
Unpacking the delivery
Inventory checking of the delivery and discrepancy reporting
Preparation of documentation for the work performed under the specific service item as part
of the site folder or link folder
Waste disposal including transportation, recycling of the waste according to our
environmental requirements and cleaning of the site in relation to and in the scope of the
works performed under the specific Service Item.
Installation planning activities for base station or transmission sites, which may include the
following
Preparation of Site Layout drawings and sketches based on existing site documentation and
drawings as part of the Site Folder for one network element or a site with all related equipment (DC
power supply, 19-inch frames or cabinets, feeder and antenna lines, antennas, peripherals, lamp
panels).
Listing of Ancillary Materials and determining their quantities (can be part of the Site Folder or
Link Folder) for the site or the network element and all related equipment.
Implementation supervising activities for a network element being implemented on a Base
Station or Cellular Transmission or core site, which may include the following
Supervising of implementation activities at site in line with local implementation processes
(including participation in the Pre Installation Site Meeting (PSIM), coordination of the implementation
activities at the site.
Verification of delivery-, installation-, commissioning-, integration- and customer signoff phases
according to the contract scope.
First line technical assistance for field teams and act as main contact with project team for fault
resolution.
Reporting of site-specific implementation progress to project management and updating of
project tools.
Controlling, scheduling and progress monitoring of field based implementation resources.
Compilation of Site or Link Folder from documents created in course of the implementation
throughout the implementation process until customer signoff.
Ensuring the site quality.
Excludes
These activities are excluded from the service item, if not indicated in the includes section of that
specific service item


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 6 of 67
Issue 2013-02-08 printed: December 11, 2013


2. 00033403 C antenna line (For complete Feeders Per site)
Commissioning of antenna line

Service
Commissioning of the antenna line in its complete length including antenna measurements. Project
specific processes and work instructions with limitations and thresholds to be reached are
applicable and will be defined accordingly.
The interface for the measurements (top of BTS or internal jumpers) will be defined from the
project.
As standard measurements can be counted tests such as Return Loss, Cable Loss, Antenna
Isolation Test and Distance To Fault. The measurement equipment such as SiteMaster has to be
calibrated and must fulfill the specifications given from the project.

Excludes
Installation of antenna.
Installation of antenna line
Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer,
triplexer, combiner, etc.
Testing of any other equipment than feederline and antenna.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 C Antenna Line 100 % 1 pcs
2 Return Loss Measurement 100 % 1 pcs Processes, work instruction and
measurement limits according the
project are applicable
3 Cable Loss Measurement 100 % 1 pcs Processes, work instruction and
measurement limits according the
project are applicable
4 Isolation Test Measurement 100 % 1 pcs Processes, work instruction and
measurement limits according the
project are applicable
5 Distance To Fault Measurement 100 % 1 pcs Processes, work instruction and
measurement limits according the
project are applicable
6 Documentation 100 % 1 pcs





Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 7 of 67
Issue 2013-02-08 printed: December 11, 2013


3. 00038272 I 7-8 antenna line basic (1 run up-to any length)
Installation of a 7/8" antenna line basic any length (As required on site)

Service
Collection of materials from the DoP/WH and its delivery to site
Dismantling and reassembly of the cable entry or gland.
Installation of 1 run 7/8" feeder cable in the required length with fixing accessories (clamps, cable
ties), grounding kits and waterproofing materials, labels and connectors.
Installation of jumper cables with fixing accessories, waterproofing materials and labels,
Termination of the antenna line to the Base Station.
Termination of the antenna line to the antenna including waterproofing of the outdoor connector (if
antenna exists).

Excludes
Installation of antenna.
Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer,
triplexer, combiner, etc.
Installation of cable support structures.
Installation of any other type of RF feeder cable.
Commisioning of antenna line and antenna

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Feeder Cable Installation 100 % 1 run Incl. Grounding and waterpr.
2 Jumper Installation 100 % 1 lot Incl. Sealing


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 8 of 67
Issue 2013-02-08 printed: December 11, 2013


4. 00038304 I Flexi BS RF modules
Installation of Flexi base station RF modules

Service
Collection of equipment and materials from the DoP/WH and its transport / delivery to site
Installation and fixing of Flexi base station plinth on floor if required.
Installation of grounding cable for the Flexi base station plinth with fixing accessories (cable ties),
labels and connectors (lugs) up to the required length including testing of the complete cable run.
Installation of Flexi base station RF modules including casing, fixing of earthquake protection
screws, front and back covers if applicable.
Installation of grounding cable between Flexi base station RF module and Flexi base station plinth
or the nearest grounding point with fixing accessories (cable ties) including testing of the complete
cable run if applicable.
Installation of delivered internal power cabling between Flexi base station RF modules and system
module, including fixing accessories (cable ties).
Installation of delivered internal databus cabling between Flexi base station RF module and system
module, including cleaning of optical connectors and fixing accessories (cable ties).
Preparation and Installation of Jumpers (including clamps and Weather proofing) as required on
site from the RF module to the Antenna.
Testing of the Jumpers (VSWR etc) if required and attach test report.
Installation of RDSA cables and FO cables between 2G and 3G modules as per given site
configuration
Re-configuration / Re-commissioning of existing 2G BTS if required
Azimuth and Tilt Adjustment for antennas if required on site.



Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 9 of 67
Issue 2013-02-08 printed: December 11, 2013


5. 00047199 I Flexi BS system module
Installation and installation testing of Flexi base station system modules

Service
Collection of equipment and materials from the WH and its delivery to site.
Installation of integrated transmission plug-in unit (Flexi base station system module).
Installation of Flexi base station system module including casing, fixing of earthquake protection
screws, front and back covers if applicable.
Installation of grounding cable between Flexi base station system module and Flexi base station
plinth with fixing accessories (cable ties) including testing of the complete cable run.
Installation of DC power cable with fixing accessories (cable ties), labels and connectors (shoes)
up to the defined length if applicable including testing of the complete cable runs.
Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the
defined length including testing of the complete cable run.
Installation of labels for DC breakers, AIB and ADM.
Terminating of FlexBus cable, fiber optic or PCM cables to the integrated transmission plug-in unit
(only for existing cables).
Installation testing of the Base Station system unit and integrated transmission plug-in unit.
Installation of DC Circuit Breaker and DCDB if required.

Excludes
Installation and Commissioning of an external DC Power Supply System.
Supply, installation and testing of transmission connections and links.
Installation and commissioning of transmission indoor unit (other than integrated).

Special cases and other requirements

Bill of Quantities
Pos Category Occ. Qnt Unit Compo
nent
Remark
1 Installation of Flexi BS system
module
100 % As
required
pcs Incl. fixing, casing, front and back
covers
2 Installation of Int. TRS PIU 100 % As
reuired
pcs Incl label, TRM vable termination
term.
3 Installation of Grounding Cable 100 % As
required
site Incl. testing
4 Installation of DC Power Cable 100 % As
required
site Incl. labeling & testing
5 Installation of Ext. Al. Cable 100 % As
required
site Incl. labeling & testing
6 Installation testing of Flexi BS
system module
100 % As
required
pcs



Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 10 of 67
Issue 2013-02-08 printed: December 11, 2013


6. 00001357 I panel antenna up to 3m
Installation of RF panel antenna higher than 0.5 and up to max. 3m

Service
Installation of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up
to the defined length.
Installation of labels for the antenna.
Installation of panel antenna bigger than 0.5m and up to 3m with its own mounting brackets and
tilting kits.
Termination of the grounding cable to the grounding termination point (port of a grounding bus bar).
Termination of the feeder line to the antenna (only if RF feeder exists).
Adjustment of the panel antenna azimuth and tilt.
Installation and commissioning of RET (2 per antenna) including the installation of RET control
cable.

Excludes
Installation of antenna holder pole or mast.
Installation of omni or panel antenna smaller than 0.5m or bigger than 2m.
Antenna line testing.

Special cases and other requirements

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Grounding Cable Installation 100 % 7 m Incl. labeling
2 RF Antenna Installation 100 % 1 pcs Inc. fixing & labeling
3 Adjustment of RF Antenna 100 % 1 pcs Azimuth, tilting
4 RET Installation 100% 2 pcs
5 RET Control cable installation 100% 2 pcs




Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 11 of 67
Issue 2013-02-08 printed: December 11, 2013


7. 00038290 IC FO cable basic
Installation and testing/commissioning of specified length of fiber optic cable or
patch cord

Service
Installation of up to specified length of fiber optic cable or patch cord with fixing accessories, labels
and connectors (if needed).
Installation of protection tube or conduit for the fiber optic cable.
Cleaning of FO connectors and plugging on both ends according installation manual
Testing of the fiber optic cable run in its complete length.
Terminating of the fiber optic cable run to the equipment or the ODF.

Excludes
Installation of fiber optic cable and its protection above specified length.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Installation of FO Pigtail Cable 100 % 1 pcs Incl. fixing and labelling
100 % 2 pcs Pigtail splicing
2 Installation of FO Cable 100 % 20 m Incl. Protection, label, term, test
3 Cleaning of FO connector 100 % 2 pcs Standard cleaning process
4 Commissioning of FO Cable 100 % 20 m Incl. Documentation


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 12 of 67
Issue 2013-02-08 printed: December 11, 2013


8. 00001382 IC IP hub type device
Installation and commissioning of IP LAN hub, switch or router

Service
Installation of AC/DC power cable with fixing accessories (cable ties), labels and connectors (cable
shoes) up to the defined length.
Installation of labels for the AC/DC breaker.
Installation of IP LAN hub, switch or router and its mounting into a 19-inch cabinet including the
installation of fixing material.
Commissioning of the IP LAN hub, switch or router if applicable.

Excludes
Installation and testing of interface cables, such as LAN.
Installation of additional cable lengths for cables delivered under this Service Item.

Special cases and other requirements
The supply of cable ties, labels and rack fixing materials (bolts and clips) is also included in this
Service Item.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 AC/DC Power Cable Installation 100 % 4 m Incl. labeling & testing
2 IP LAN Device Installation 100 % 1 pcs
3 IP LAN Device Commissioning 100 % 1 pcs


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 13 of 67
Issue 2013-02-08 printed: December 11, 2013


9. 00038297 IC LAN cable basic
Installation and testing/commissioning of basic length of LAN cable

Service
Installation of LAN cable with fixing accessories, labels and connectors.
Testing of the LAN cable run in its complete length (if applicable).
Terminating of the LAN cable to an existing patch panel at each end.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 LAN Cable Installation 100 % 10 m Incl label, term, test


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 14 of 67
Issue 2013-02-08 printed: December 11, 2013


10. 00045202 IC remote RF module feed basic (Per site)
Installation of remote RF module feed

Service
Installation and fixing of the OVP boxes if applicable.
Installation of grounding cable for the OVP boxes with fixing accessories (cable ties), labels and
connectors (lugs) up to the defined length including testing of the complete cable run if applicable.
Installation of AC or DC power cable with fixing accessories (cable ties), labels and connectors
(shoes) up to the defined length if applicable including testing of the complete cable runs if
applicable.
Installation of labels for AC or DC breakers if applicable
Installation of fibre optic cable with fixing accessories (cable ties), labels and connectors up to the
defined length, including cleaning of connector and testing of the complete cable runs.
Installation of protection tube or conduit for the fiber optic cable if required
Testing of the fiber optic cable run in its complete length.

Excludes
Installation of Flexi WCDMA base station system module(s) or/and RF module(s)
Installation of 19" rack, Flexi plinth, indoor FCIA cabinet or outdoor FCOA cabinet.
Installation and commissioning of base station antenna line.
Installation and commissioning of an external DC power supply system.
Transportation of the equipment to the site.

Bill of Quantities
Pos Category Occ. Qnt Unit Comp
onent
Remark
1 Installation of OVP box 100 % As required
on site
pcs Incl. fixing or pole mounting
2 Installation of grounding cable 100 % As required pcs Incl. labeling & testing, length 3m
3 Installation of DC power cable 100 % As required m Incl. labeling & testing
4 Installation of FO Cables 100 % As required m Incl. labeling & testing


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 15 of 67
Issue 2013-02-08 printed: December 11, 2013


11. 00039294 InstM Flexi BS
Installation materials for Flexi base station

Material

Bill of Quantities
Pos Category Occurrence Qnt Unit Remark
1 Grounding cable complete 100% 3 m MK 16 GND CABLE Y/G (reel)
100% 2 pcs RS Cable shoe 16mm2 / M8
2 DC Power Cable Complete 100% 10 m DC cable 2x16mm2
100% 4 pcs Cable lug, 16mm2
3 LAN Cable Complete 100% 10 m Pre-made LAN cable
4 Label 100% 2 pcs Label as per Mobily Standard
100% 0.04 pcs Cable tie, 100pcs


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 16 of 67
Issue 2013-02-08 printed: December 11, 2013


12. 00073261 BTS INST. MATERIALS
Installation materials for Flexi base station

Material

Bill of Quantities
Pos Category Occurrence Qnt Unit Remark
1 Grounding cable complete 100% 3 m MK 16 GND CABLE Y/G (reel)
100% 2 pcs RS Cable shoe 16mm2 / M8
2 DC Power Cable Complete 100% 10 m DC cable 2x16mm2
100% 4 pcs Cable lug, 16mm2
3 LAN Cable Complete 100% 10 m Pre-made LAN cable
4 Label 100% 2 pcs Label as per Mobily Standard
100% 0.04 pcs Cable tie, 100pcs
5 DC Circuit Breaker 63
Amps
100% 1 pcs As per Mobily required Brand


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 17 of 67
Issue 2013-02-08 printed: December 11, 2013


13. 00007502 M LAN cable basic
Material for basic length of LAN cable

Material
Supply of LAN cable with fixing accessories, labels and connectors.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 LAN Cable Complete 100 % 1 pcs CS73099.15 pre-made 15m LAN c
2 Label 100 % 2 pcs CS73331.10 LAN cable label (Brady 511)
100 % 0.04 pcs CS73320.04 Cable tie, 100pcs


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 18 of 67
Issue 2013-02-08 printed: December 11, 2013


14. 00045205 M remote RF module feed add (2x5m)
Additional Installation materials for remote RF module feed

Material
Supply of additional DC power cable if applicable with fixing accessories depending on the type
and configuration of the cable basic length.

Excludes
Supply of basic length of the AC or DC cable.
Supply of basic length of the fiber optic cable.
Supply of basic length of the protection tube or conduit.

Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
2 DC Power
Cable
100% 10 m CSxxx 2x6mm2 with rubber insulation for
Outdoor Installation
3 Clamps 100% 5 pcs CSxxx Clamps for DC cable and FO


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 19 of 67
Issue 2013-02-08 printed: December 11, 2013


15. 00045204 M remote RF module feed basic (2x20m)
Installation materials for remote RF module feed

Material
Supply of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up to
the defined length.
Supply of DC power cable with fixing accessories (cable ties), labels and connectors (shoes) up to
the defined length.

Bill of Quantities
Pos Category Occurr
ence
Qnt Uni
t
Component Remark
1 Grounding cable
complete
100% 2 pcs CS73178 MKEM-LSZH 16 y/g inst. cable (reel), length
3m
100% 4 pcs CS73226.06 RS Cable shoe 16mm2 / M8
100% 0.4 m CS73327.12 Shrink sleeve
100% 0.2
4
pcs CS73320.01 Cable tie, 100pcs
2 DC Power
Cable Complete
100% 40 m CSxxx 2x6mm2 with rubber insulation for Outdoor
Installation
100% 4 pcs CSxxx Cable lugs
100% 0.2 m CS73327.12 Shrink sleeve
100% 0.8 pcs CS73320.01 Cable tie, 100pcs
3 Clamps 100% 20 pcs CSxxx Clamps for DC cable and FO
4 Labels 100% 2 pcs CSxxx DC cable label
100% 0.0
4
pcs CS73320.01 Cable tie, 100pcs
100% 2 pcs CSxxx FO cable label


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 20 of 67
Issue 2013-02-08 printed: December 11, 2013


16. 00038731 M singlemode FO cable basic
Material of singlemode fiber optic cable

Material
Supply of up to specified length of singlemode fiber optic cable with fixing accessories, labels and
connectors.
Supply of protection tube or conduit for the fiber optic cable.(if needed)

Excludes
Supply of fiber optic cable and its protection above specified length.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Singlemode FO Cable Complete 100 % 1 pcs CS73505.20 Premade Rugged duplex jumper
cable 20m
100 % 0.4 pcs CS73320.04 Cable tie, 100pcs
2 Label 100 % 2 pcs Indoor cable label


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 21 of 67
Issue 2013-02-08 printed: December 11, 2013


17. 00000890 Multiple travel
Travel of multiple persons to the site

Service
All travel related to carry out the tasks in the sales package by one or multiple persons.
Travel by car (station wagon, MPV, or off-road SUV), or train or other means needed for the work
team to get to the site. Travel by ferry for the person(s) and the car if needed.
Travel time cost of the person or persons including accommodation if overnight stay is needed as
long as required for completing the agreed tasks in the sales package.
Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or
carrying capacity of the persons and moving of the transported tools, materials or equipment onto
and from the site (equipment room, battery room, rooftop, any other part of the site).
Insurance of the persons, vehicles, tools, materials and equipment within the scope of this Service
Item.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Travel 100 % 1 pcs All travel related to the sales package


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 22 of 67
Issue 2013-02-08 printed: December 11, 2013


18. 00056303 On site BS integration
On site activities to integrate a BTS as a part of the network

Service
Transmission verification including physical connections (E1/T1, FlexBus, optical fiber)
Setting site specific parameters
Downloading Site Configuration File (SCF)
Initiate communication with remote engineer to support remote functional verification

Excludes
Installation of a DDF/ODF block
Installation of transmission cable
Manual commissioning

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 On site BS integration 100 % 1


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 23 of 67
Issue 2013-02-08 printed: December 11, 2013


19. 00001513 Rem BTS/BSC/TCSM modules
Removal of BTS/BSC/TCSM modules

Service
Decommissioning of modules.
Disconnection and removal of internal cabling (if applicable).
Removal of labels from the modules.
Removal and packaging of the modules.
Installing dummy panels instead of the removed plug-in units (if applicable).
Collecting of the removed items in a designated area at the site.
Transport of the removed modules back to the WH.

Bill of Quantities
Pos Category Occ. Qnt Unit Compone
nt
Remark
1 PIU Decommissioning 100 % As
require
on site
pcs
2 PIU Removal and
transport
100 % As
require
on site
pcs


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 24 of 67
Issue 2013-02-08 printed: December 11, 2013


20. 00001485 Site survey BS site


Service
Conduct of a site survey on a base station site and preparation of related documents including
photographs (if applicable) and the relevant site survey check list.

Excludes

Special cases and other requirements
This Service Item may include multiple network elements, which are implemented at the same
phase at the same site.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Site Survey 100 % 1 pcs Per survey


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 25 of 67
Issue 2013-02-08 printed: December 11, 2013


21. 00001487 Transport DOP/Site to Site 0-3,5t regulr
Transportation of low-volume cargo

Service
Carrying or moving cargo from the storage area, or in case of removal, from a designated area at
the site, and loading of the cargo onto the vehicle as described below.
Transportation of tools, materials or equipment in a truck/lorry with the payload capacity up to 3.5
tons for an initial distance from the storage area to site. (or return travel of the vehicle).
Transportation of the same volume of cargo by train.
Travel by ferry for the passangers and the vehicle in both directions if needed.
Carrying or moving the cargo from the vehicle into the equipment room, battery room, rooftop or
other designated area at the site, or in case of removal, into the storage area.
Accommodation of the or passangers and secure parking of the vehicle if overnight stay is needed.
Insurance of the persons, vehicle, tools, materials and equipment within the scope of this Service
Items.

Excludes
Transportation of cargo in a vehicle with the payload capacity above 3.5 tons.
Transportation by helicopter.
Hoisting of the cargo by crane.
Travel of personnel other than the driver and the aids for cargo loading and unloading.

Special cases and other requirements
This Service Item also covers the cases where one aditional stop is made on the route to and on
the route back from the destination for the purpose of loading or unloading additional cargo up to
the capacity of the vehicle, which is used especially for microwave links.
In case of shipping the cargo by airplane, this Service Item shall be ordered in such a quantity so
that the price of the air-ticket and handling or storing of the cargo at the airport is compensated.

Bill of Quantities
Pos Category Occ. Qnt Unit Component Remark
1 Transport DOP/Site to Site 0+3,5t regulr 100 % 200 km 100km in 2 dirs, accom.


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 26 of 67
Issue 2013-02-08 printed: December 11, 2013


22. 00001344 I BSC
Installation of BSC
Service
Installation of rack mounting rails with fixing materials up to the defined length per rail (if
applicable).
Installation of grounding cable with fixing accessories (cable ties), labels and connectors (cable
lugs) up to the defined length.
Installation of power cables with fixing accessories (cable ties), labels and connectors (cable
lugs) up to the defined length.
Installation of an external alarms cable with fixing accessories (cable ties), labels and connectors
up to the defined length.
Installation of an analogue X.25 cable with fixing accessories (cable ties), labels and connectors
up to the defined length.
Installation of labels for the grounding termination point (port of a grounding bus bar), DC power
breakers, DDF block, AIB or ADM.
Installation and testing of clock synchronization cable with fixing accessories (cable ties), labels
and connectors up to the defined length. (if applicable)
Cutting of computer floor tiles and dressing cut edges with suitable edging material or/and
installing cable flanges (if applicable).
Installation of the BSC cabinet and its fixing to the rails (if applicable) or floor including the fixing
material.
Installation (insertion) of plug-in units as delivered for the BSC up to the maximum configuration.
Excludes
Installation of subsequent BSC extensions.
Installation and testing of interface cables, such as PCMs or LAN.
Installation of additional cable lengths for cables delivered under this Service Item.
Special cases and other requirements
Cross connection of external alarms in Alarm Distribution Module is not considered as it is
assumed that the incoming alarms and the external alarms cable share the same ADM block.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Rack Mount Rail Installation 100% 2 pcs
2 Cable Flange Installation 100% 1 pcs Incl. floor cutting
3 Grounding Cable Installation 100% 50 m Incl. labeling & testing
4 DC Power Cable Installation 100% 200 m Incl. labeling & testing
5 Ext. Alarms Cable Installation 100% 50 m Incl. labeling & testing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 27 of 67
Issue 2013-02-08 printed: December 11, 2013


6 An. X.25 Cable Installation 0% 18 m Incl. labeling & testing
7 Cabinet Installation 100% 1 pcs Incl. fixing, voltage ch.
8 PIU Installation 100% 1 pcs Includes all the delivered
PIUs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 28 of 67
Issue 2013-02-08 printed: December 11, 2013


23. 00001383 IC lamp panel
Installation and commissioning of alarm panel or alarm interface box (TIF)
Service
Installation of alarm panel or TIF(telemetry interface) signaling cable up to the defined length
including fixing accessories (cable ties), labels and connectors.
Installation of multi-core DC power cable for the alarm panel up to the defined length including
fixing accessories (cable ties), labels and connectors (cable shoes).
Installation of label for the alarm panel or TIF signalling.
Installation and commissioning of alarm panel or TIF signalling.
Excludes
Installation of additional power or interface cable.
Special cases and other requirements
The supply of cable ties and labels is also included in this Service Item.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Cable Installation 100% 3 pcs Connector fitting
2 Power Cable Installation 100% 4 pcs Connector fitting
3 alarm panel Installation 100% 1 pcs
4 alarm panel Commissioning 100% 1 pcs
5 TIF Installation and Commissioning 0% 1 pcs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 29 of 67
Issue 2013-02-08 printed: December 11, 2013


24. 00001390 I MHA-TMA
Installation and commissioning of Mast Head Amplifier
Service
Installation of grounding cable with fixing accessories (cable ties), labels and connectors (lugs)
up to defined length.
Termination of the grounding cable to the grounding termination point (port of a grounding bus
bar).
Installation of additional fixing material for the MHA, such as steel bands, etc.
Installation of MHA with its own mounting brackets, clamps or additional fixing material including
connection to the antenna line (only if RF feeder exists) with installation of waterproofing.
Installation of additional jumper with fixing materials and abels including installation of
waterproofing.
Installation of label for the MHA.
Excludes
Commisioning of antenna line and antenna
Installation of Bias Tee.
Installation of antenna line including other active and passive components.
Special cases and other requirements
If the antenna line is installed in the same time like the MHA, installation of waterproofing for the
RF feeder-MHA connector as well as termination of the RF feeder to the MHA are part of the
antenna line installation.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Jumper cable installation 100% 1 lot DNxxx incl, labeling
2 Grounding Cable Installation 100% 7 m DNxxx Incl. labeling
4 MHA Installation 100% 1 pcs DNxxx Inc. fixing & labeling

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 30 of 67
Issue 2013-02-08 printed: December 11, 2013


25. 00001413 ICIntg PIU ext
Installation, Commissioning and Integration of Plug-in unit extension
Service
Installation (insertion) of the extended plug-in unit/s in question
Installation of intercabinet cabling (if applicable)
Commissioning of extended plug-in unit/s
Integration of extended plug-in unit/s
Excludes
Testing of interface cables, such as PCMs, external alarm cable, X.25 cable, clock
synchronization cable, etc.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Core PIU Installation 100% 8 pcs DNxxx
2 Core PIU Commissioning 100% 8 pcs DNxxx Incl. ext cable term.
3 Core PIU Integration 100% 8 pcs DNxxx

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 31 of 67
Issue 2013-02-08 printed: December 11, 2013


26. 00001515 Rem proprietary PCM
Removal of proprietary PCM
Service
Deinstallation of one DDF block.
Deinstallation of PCM cable, including jumper cables and fixing material up to the defined length
per cable.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Removal of cables 100% 1 pcs DNxxx As required on site

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 32 of 67
Issue 2013-02-08 printed: December 11, 2013


27. 00001516 Rem subrack server or IP hub device
Removal of subrack mounted/housed server or IP LAN device
Service
Disconnection and removal of AC power cable of the cabinet including fixing in the defined
length (if applicable).
Removal of labels from the AC breakers and 19-inch frame.
Removal of fixing materials of the server/LAN device or its shelf.
Removal and packaging of the server/LAN device.
Collecting of the removed items in a designated area at the site.
Excludes
Removal of 19-inch frame or cabinet.
Removal of plug-in units, batteries or subracks.
Removal of additional cables.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Cable Removal 100% As
required
on site
m DNxxx Incl. remov of fixing
2 Server/LAN Device Removal 100% 1 pcs DNxxx Incl. packaging

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 33 of 67
Issue 2013-02-08 printed: December 11, 2013


28. 00003379 I blade server chassis
Installation blade server chassis hardware (Juniper or Megamon)
Service
Installation of the blade server chassis and plug-in units into a rack.
Connecting of the chassis grounding cable to the rack.
Installation of chassis alarm cable with connector to DDF.
Installation of DC or AC power cable with fixing accessories (cable ties), labels and connectors.
Connecting of internal cablings.
Installation of labels for the DC breaker(s).
Excludes
Installation of a 19 inch rack.
Installation and testing of interface cables, such as STM1 or LAN.
Installation of additional cable lengths for cables delivered under this Service Item.
Installation of plug-in units, which are not part of the delivery of the blade server.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Chassis installation 100% 1 pcs DNxxx
2 Ground cable installation 100% 1 pcs DNxxx
3 Alarm cable installation 100% 1 pcs DNxxx Incl. labeling & testing
4 AC or DC Power Cable Installation 100% As
required
m DNxxx Incl. labeling & testing
5 Plug-in unit installation 100% As
required
pcs DNxxx

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 34 of 67
Issue 2013-02-08 printed: December 11, 2013


29. 00003934 Site survey core
Site survey of a BSC-TCSM-RNC-Core site
Service
Conduct of a site survey and preparation of related documents including photographs (if
applicable) and the relevant site survey check list.
Agreement of site details with customer representative, if applicable.
Confirmation of site access.
Excludes
Special cases and other requirements
This Service Item may include multiple network elements, which are implemented at the same
phase at the same site.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Site Survey BSC-TCSM-RNC-core 100% 1 pcs Site Survey
template
document
per Survey

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 35 of 67
Issue 2013-02-08 printed: December 11, 2013


30. 00003957 Rem cabinet BSC-RNC
Removal of BSC or -RNC cabinet
Service
Decommissioning and physical switch off of the cabinet.
Disconnection and removal of AC power cable of the cabinet including fixing (if applicable).
Disconnection and removal of of DC cable of the cabinet including fixing (if applicable).
Disconnection and removal of grounding cable of the cabinet including fixing .
Disconnection and removal of Q1 cable of the cabinet including fixing in the length (if
applicable).
Disconnection and removal of external alarms cable of the cabinet including fixing in the length
(if applicable).
Disconnection and removal of analogue X.25 cable of the cabinet including fixing in the length
(if applicable).
Disconnection and removal of clock synchronization cable of the cabinet including fixing (if
applicable).
Removal of labels from the AC or DC breakers, DDF blocks, cable termination points.
Removal of fixing materials of the cabinet.
Dismantling and packaging of enclosures of the cabinet, such as doors, if applicable.
Removal and packaging of the cabinet.
Collecting of the removed items in a designated area at the site.
Excludes
Cabinet de-integration support in NSS or NMS.
Removal of 19-inch frame or cabinet.
Removal of plug-in units, batteries or subracks.
Removal of upgrade kits.
Removal of power cabinet.
Removal of additional cables.
Removal of more than one BSC or RNC cabinet.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 De-commissioning 100% 1 pcs DNxxx Data clean up in cabinet
100% 1 pcs DNxxx Physical switch off cabinet

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 36 of 67
Issue 2013-02-08 printed: December 11, 2013


2 Cable Removal 100% As
required
m DNxxx Incl. remov of fixing - 2 x
pair of power feeds for 1
cabinet
100% As
required
m DNxxx Removal of ground cable
3 Door Set Removal 100% 1 pcs DNxxx incl. packaging
4 Cabinet Removal 100% 1 pcs DNxxx Incl. Packaging and inter
cabling

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 37 of 67
Issue 2013-02-08 printed: December 11, 2013


31. 00033865 Travel low
Travel low
Service
All travel related to carry out the tasks in the sales package by one or more people, which
normally only takes part of a day to implement.
Travel by car (station wagon, MPV, or off-road SUV), or train or other means needed for the
work team to get to the site. Travel by ferry for the person(s) and the car if needed.
Travel time cost of the person or persons including accommodation if overnight stay is needed
as long as required for completing the agreed tasks in the sales package.
Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or
carrying capacity of the persons and moving of the transported tools, materials or equipment
onto and from the site (equipment room, battery room, rooftop, any other part of the site).
Insurance of the persons, vehicles, tools, materials and equipment within the scope of this
service item.
Excludes
Transportation of goods above the capacity of the car or the persons.
Travel by helicopter.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Travel low 100% 1 pcs N/A All travel related to the sales
package

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 38 of 67
Issue 2013-02-08 printed: December 11, 2013


32. 00033872 Travel TRS
Travel transmission
Service
All travel related to carry out the tasks in the sales package by one or more people on a MWR
end or similar task, which normally only takes part of a day to implement.
Travel by car (station wagon, MPV, or off-road SUV), or train or other means needed for the
team to get to the site. Travel by ferry for the person(s) and the car if needed.
Travel time cost of the person or persons including accommodation if overnight stay is needed
as long as required for completing the agreed tasks in the sales package.
Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or
carrying capacity of the persons and moving of the transported tools, materials or equipment
onto and from the site (equipment room, battery room, rooftop, any other part of the site).
Insurance of the persons, vehicles, tools, materials and equipment within the scope of this
service item.
Excludes
Travel by helicopter.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Travel Transmission 100% 1 pcs N/A All travel related to the sales
package

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 39 of 67
Issue 2013-02-08 printed: December 11, 2013


33. 00033875 Rem cabinet BSC-RNC add
Removal of an additional BSC-RNC cabinet
Service
Decommissioning and physical switch off of the cabinet.
Disconnection and removal of AC power cable of the cabinet including fixing (if applicable).
Disconnection and removal of up to four runs of DC cable of the cabinet including fixing (if
applicable).
Disconnection and removal of grounding cable of the cabinet including fixing .
Disconnection and removal of Q1 cable of the cabinet including fixing in the defined length (if
applicable).
Disconnection and removal of external alarms cable of the cabinet including fixing in the defined
length (if applicable).
Disconnection and removal of analogue X.25 cable of the cabinet including fixing in the defined
length if applicable).
Disconnection and removal of clock synchronization cable of the cabinet including fixing (if
applicable).
Removal of labels from the AC or DC breakers, DDF blocks, cable termination points.
Removal of fixing materials of the cabinet.
Dismantling and packaging of enclosures of the cabinet, such as doors, if applicable.
Removal and packaging of the cabinet.
Collecting of the removed items in a designated area at the site.
Excludes
Cabinet de-integration support in NSS or NMS.
Removal of 19-inch frame or cabinet.
Removal of additional cables.
Removal of more than one BSC or RNC cabinet.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 De-commissioning 100% 1 pcs DNxxx Data clean up in cabinet
100% 1 pcs DNxxx Physical switch off cabinet
2 Cable Removal 100% As
required
m DNxxx Incl. remov of fixing - 2 x
pair of power feeds for 1
cabinet
100% As m DNxxx Removal of ground cable

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 40 of 67
Issue 2013-02-08 printed: December 11, 2013


required
3 Door Set Removal 100% 1 pcs DNxxx DX200, incl. packaging
4 Cabinet Removal 100% 1 pcs DNxxx DX200 Incl. Packaging and
inter cabling

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 41 of 67
Issue 2013-02-08 printed: December 11, 2013


34. 00038266 I 1 5-8 antenna line basic (1 run upto any length)
Installation of a 1 5/8" antenna line in required length
Service
Dismantling and reassembly of the cable entry or gland.
Installation of 1 5/8" feeder cable in the required length with fixing accessories (clamps, cable
ties), grounding kits and waterproofing materials, labels and connectors.
Installation of jumper cables with fixing accessories, waterproofing materials and labels,.
Termination of the antenna line to the Base Station.
Termination of the antenna line to the antenna including waterproofing of the outdoor connector
(if antenna exists).
Excludes
Installation of antenna.
Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer,
triplexer, combiner, etc.
Installation of cable support structures.
Installation of any other type of RF feeder cable.
Commissioning of antenna line and antenna
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Feeder Cable Installation 100% As
required
at site
m DNxxx Incl. Grounding and
waterpr.
2 Jumper Installation 100% 1 lot DNxxx Incl. Sealing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 42 of 67
Issue 2013-02-08 printed: December 11, 2013


35. 00038268 I RDSA Cables (For Diversity Sharing)
Installation of RDSA cables for Diversity Sharing between 2G and UMTS900
Service
Installation of RDSA cables and FO cables between 2G and UMTS900 modules as per site
configuration
Re-configuration / Re-commissioning of existing 2G BTS if required
Azimuth and Tilt Adjustment of antennas if required on site
Any other work required to complete the work on site

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 43 of 67
Issue 2013-02-08 printed: December 11, 2013


36. 00038285 I floor mount 19-23 cab
Installation of floor mount 19-23 inch cabinet
Service
Installation of a floor-standing 19 or 23 inch cabinet with floor fixing material and label.
Installation of an AC power distribution strip for the 19 or 23 inch cabinet with mounting material.
Installation of AC power cable with fixing material and labels up to the defined length.
Installation of DC power cable with fixing material, labels and connectors (lugs) up to the defined
length.
Installation labels for AC power breaker and ground termination point (bus bar port).
Installation of the grounding cable up to the defined length including labeling of the ground
termination point
Excludes
Installation of DC power distribution frame.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 19-23 inch Cabinet Installation 100% 1 pcs DNxxx Floor-standing
2 19-23 inch Cabinet AC Strip Install. 100% 1 pcs DNxxx
3 Grounding Cable Installation 100% 7 m DNxxx Incl. labeling & testing
4 AC Power Cable Installation 100% 7 m DNxxx Incl. labeling & testing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 44 of 67
Issue 2013-02-08 printed: December 11, 2013


37. 00038559 InstM BSC
Installation material for BSC, 1 cabinet
Material
Supply of rack mounting rails with fixing materials up to the defined length per rail (if applicable).
Supply of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up to
the defined length.
Supply of power cable with fixing accessories (cable ties), labels and connectors (cable shoes)
up to the defined length.
Supply of an external alarms cable with fixing accessories (cable ties), labels and connectors up
to the defined length..
Supply of labels for the grounding termination point (port of a grounding bus bar), DC power
breakers, DDF block, AIB or ADM.
Supply of clock synchronization cable with fixing accessories (cable ties), labels and connectors
up to the defined length.
Supply of suitable edging material or/and supplying cable flanges (if applicable).
Supply of fixing material.
Excludes
Installation material for subsequent BSC extensions.
Supply of interface cables, such as PCM, LAN or STM-1
Supply of additional cable lengths for cables delivered under this Service Item.
Special cases and other requirements
Cross connection material for external alarms in Alarm Distribution Module is not considered as
it is assumed that the incoming alarms and the external alarms cable share the same ADM
block.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Rack Mount Rail Complete 100% 2 pcs CS73349.02 Floor Rails 895mm
100% 1 pcs CS73217.04 Fasteners for rails, 1PCS per
cabinet
100% 1 pcs CS73222.20 Floor rail Installation det,
1PCS per cabinet, includes
two cabinet support bars for
each cabinet, their
attachment parts.
2 Ground Cable Complete 100% 50 m CS73179 Grounding cable, 25mm2
100% 1 pcs CS73226.08 Gnd cable lug, 25mm2
3 DC Power Cable Complete 100% 100 m CS73180.01 DC cable black 35mm2,

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 45 of 67
Issue 2013-02-08 printed: December 11, 2013


100% 100 m CS73180.02 DC cable blue 35mm2,
100% 8 pcs CS73226.09 DC cable ferrule, 35mm2
100% 1 m CS73327.12 Shrink sleeve black
100% 1 m CS73327.10 Shrink sleeve blue
4 Ext. Alarms Cable Complete 100% 1 pcs CS73131.50 Ext. al. cable, pre-made, 50m
5 Comp. Floor Cable Flange 100% 1 pcs CS73339.20 Insulation tape 19*18 black
6 Label 100% 1 pcs CS73331.10 Cable label set
7 Fixing accessories 100% 1 pcs CS73320.01 Cable tie, 100pcs
100% 1 pcs CS73320.05 Cable tie, 100pcs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 46 of 67
Issue 2013-02-08 printed: December 11, 2013


38. 00038637 InstM packaging for cables
Packaging material for cables
Material
Supply of packaging material.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Packaging Material 100% 1 pcs Reel for cables
0% 1 pcs Box for fixing materials and
grounding kits (50pcs)

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 47 of 67
Issue 2013-02-08 printed: December 11, 2013


39. 00038638 InstM packaging for PIUs
Packaging material for plug in units
Material
Supply of packaging material.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Packaging Material 100% 1 pcs box type Box for PIUs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 48 of 67
Issue 2013-02-08 printed: December 11, 2013


40. 00038640 InstM packaging for cabinet
Packaging material for cabinet
Material
Supply of packaging material.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Packaging Material 100% 1 pcs Box for cabinet

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 49 of 67
Issue 2013-02-08 printed: December 11, 2013


41. 00039295 I indoor Flexi BS cab
Installation of indoor Flexi base station cabinet
Service
Installation and fixing of indoor Flexi base station cabinet.
Installation of grounding cable for the indoor Flexi base station cabinet with fixing accessories
(cable ties), labels and connectors (lugs) up to the defined length including testing of the
complete cable run.
Excludes
Installation of more than one indoor Flexi base station cabinet.
Installation of 19" rack, outdoor FCOA cabinet or Flexi base station plinth
Transportation of the equipment to the site.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Installation of indoor Flexi BS cabinet 100% 1 pcs DNxxx Incl. fixing
2 Installation of Grounding Cable 100% 3 m DNxxx Incl. labeling & testing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 50 of 67
Issue 2013-02-08 printed: December 11, 2013


42. 00040307 I ODF block or module
Installation of ODF block or module.
Service
Installation of ODF block or module into existing frame (e.g.: patch module, splice module, FO
splitter module) including
labeling and fixing accessories.
Excludes
Installation of ODF frame.
Installation of ODF chassis or shelf.
Special cases and other requirements
NOTE: In some countries the installation standards may require special license or permissions
from Local Telecom Company and authorities. When localizing this generic item check the
country specific legislation. Installation manuals and tools have to be used.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 ODF block or module installation 100% 1 pcs DNxxx Incl. labeling and fixing
accessories

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 51 of 67
Issue 2013-02-08 printed: December 11, 2013


43. 00040308 M ODF block (48 ports)
Material for an ODF block 48 ports Tyco type as per Mobily specifications.
Material
Supply of an ODF block including mounting materials.
Supply of labels for the ODF block
Excludes
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 ODF block 100% 1 pcs CSxxx
2 Block Mount Material 100% 4 pcs CSxxx Bolt
100% 4 pcs CSxxx 19" rail clip w/ nut
3 Label 100% 1 pcs CSxxx Block label


Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 52 of 67
Issue 2013-02-08 printed: December 11, 2013


44. 00038565 InstM TCSM
Installation material for TCSM, 1 cabinet
Service
Material
Supply of rack mounting rails with fixing materials.
Supply of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up to
the defined cable length.
Supply of power cable with fixing accessories (cable ties), labels and connectors (cable lugs) up
to the defined cable length.
Supply of labels for the TMGB and DC power breakers.
Supply of suitable edging material or/and supplying cable flanges (if applicable).
Supply of fixing material.
Excludes
Supply of interface cables, such as PCMs or LAN
Installation material for subsequent TCSM extensions.

Special cases and other requirements
Bill of Quantities
Pos Category Qnt Unit Component Remark
1 Rack Mount Rail
Complete
2 pcs CS
73349.03
Floor Rails 1190mm
1 pcs CS
73217.04
Fasteners for rails, 1PCS per
cabinet
1 pcs CS
73222.20
Floor rail Installation det, 1PCS
per cabinet, includes two
cabinet support bars for each
cabinet, their attachment parts.
2 Ground Cable
Complete
50 m CS73179 y/g 25mm2
2 pcs CS73226.08 Cable lug, 25mm2
3 DC Power Cable
Complete
50 m CS73180.01 DC cable black 35mm2, 2x
50 m CS73180.02 DC cable blue 35mm2, 2x
4 pcs CS73226.09 DC cable shoe
1 m CS73327.12 Shrink sleeve black
1 m CS73327.10 Shrink sleeve blue
4 Comp. Floor Cable
Flange
2 pcs CS73339.20 Insulation tape 19*18 black
5 Label set 1 pcs CS73331.10 Cable label set
6 Fixing accessories 1 pcs CS73320.01 Cable tie, 100pcs
1 pcs CS73320.05 Cable tie, 100pcs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 53 of 67
Issue 2013-02-08 printed: December 11, 2013


45. 00001361 I TCSM
Installation of TCSM
Service
Installation of rack mounting rails with fixing materials.
Installation of grounding cable with fixing accessories (cable ties), labels and connectors (lugs)
up to the defined cable length.
Installation of power cable with fixing accessories (cable ties), labels and connectors (cable lugs)
up to the defined cable length.
Installation of labels for the TMGB and DC power breakers.
Cutting of computer floor tiles and dressing cut edges with suitable edging material or/and
installing cable flanges (if applicable).
Installation of the TCSM cabinet on the floor or fixing to the rails.
Installation (insertion) of plug-in units as delivered for the TCSM up to the maximum
configuration.

Material
Excludes
Installation of subsequent TCSM extensions.
Installation of additional cable lengths.

Special cases and other requirements
Bill of Quantities
Pos Category Qnt Unit Component Remark
1 Rack Mount Rail
Installation
2 pcs
2 Cable Flange
Installation
1 pcs Incl. floor cutting
3 Grounding Cable
Installation
50 m Incl. labeling & testing
4 DC Power Cable
Installation
200 m Incl. labeling & testing
5 DX200 Cabinet
Installation
1 pcs Incl. fixing, PIUs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 54 of 67
Issue 2013-02-08 printed: December 11, 2013


46. 00073251 Implementation BTS 2G and UMTS900 for swap
Installation, Commissioning & Integration of 2G Flexi MR BTS to Swap existing 2G BTS and
Installation, Commissioning and Integration of UMTS900 at the same time with Diversity sharing
using RDSA cable.
Service
Collection of the equipment and materials from the DoP/WH and its transportation / delivery to
the site including loading unloading etc.
Travel of Implementation teams to the site
Preparation for swap of 2G including alarm checking etc
Installation and fixing Base Station cabinet/rack if applicable.
Installation of Base Station modules including casing, fixing of earthquake protection screws,
front and back covers if applicable.
Installation of grounding cable for the Base Station with fixing accessories (cable ties), labels
and connectors (lugs) up to the defined length including testing of the complete cable run.
Installation of Circuit Breakers including labeling
Installation of power cable with fixing accessories (cable ties), labels and connectors (shoes) up
to the defined length including testing of the complete cable runs.
Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the
defined length including testing of the complete cable run if applicable
Installation of transmission cable(s) with fixing accessories (cable ties), labels and connectors up
to the defined length including testing of the complete cable run if applicable
Installation of internal cabling not limited to DC Power cable(s), grounding cable(s) and databus
cable(s) if applicable
Connecting RF antenna lines and jumpers to the BTS including installation of new jumpers and
RDSA cable.
Installation of labels for DC breakers, AIB and ADM.
Powering-up, Commissioning and integration of the 2G and 3G Base Stations.
Cut-over from existing 2G BTS to the new Flexi 2G BTS
Antenna Azimuth and Tilt adjustment if required
Clear all the HW snags from the Punch List
Create Site HW documentation for Site HW Acceptance and submit to NSN in hard and soft
format as agreed.
Fall-back to the old 2G BTS, in case of swap failure
Any other related work required on site for complete Implementation
All the coordination with NSN and Mobily staff to complete the Implementation work

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 55 of 67
Issue 2013-02-08 printed: December 11, 2013



Excludes
Supply, Installation and Commissioning of an external DC Power Supply System, MW or IP
Transmission. Removal of Existing 2G BTS.

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 56 of 67
Issue 2013-02-08 printed: December 11, 2013


47. 00073252 BTS Implementation TDD LTE for Swap sites
Installation, Commissioning & Integration of Flexi MR TDD LTE BTS Feeder-less to Swap
existing TDD LTE BTS Feeder-less
Service
Collection of the equipment and materials from the DoP/WH and its transportation / delivery to
the site including loading unloading etc.
Travel of Implementation teams to the site
Preparation for swap of TDD LTE including alarm checking etc
Installation and fixing Base Station cabinet/rack if applicable.
Installation of Base Station modules (System Modules in the Shelter and RF Modules on the
Tower Top) including casing, fixing of earthquake protection screws, front and back covers if
applicable.
Installation of grounding cable for the Base Station with fixing accessories (cable ties), labels
and connectors (lugs) up to the defined length including testing of the complete cable run.
Installation of Circuit Breakers including labeling
Installation of power cable with fixing accessories (cable ties), labels and connectors (shoes) up
to the defined length including testing of the complete cable runs.
Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the
defined length including testing of the complete cable run if applicable
Installation of transmission cable(s) with fixing accessories (cable ties), labels and connectors up
to the defined length including testing of the complete cable run if applicable
Installation of internal cabling not limited to DC Power cable(s), grounding cable(s) and databus
cable(s) if applicable
Connecting RF antenna lines and jumpers to the BTS including installation of new jumpers.
VSWR and Return Loss measurement for jumpers if required
Installation of labels for DC breakers, AIB and ADM.
Powering-up, Commissioning and integration of the Base Station.
Cut-over from existing LTE BTS to the new Flexi MR LTE BTS
Remove existing LTE BTS RRHs and accessories such as FO and Power cables etc. from the
tower and place them inside the shelter
Antenna Azimuth and Tilt adjustment if required
Clear all the HW snags from the Punch List
Create Site HW documentation for Site HW Acceptance and submit to NSN in hard and soft
format as agreed.
Fall-back to the old LTE BTS, in case of swap failure

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 57 of 67
Issue 2013-02-08 printed: December 11, 2013


Any other related work required on site for complete Implementation
All the coordination with NSN and Mobily staff to complete the Implementation work

Excludes
Supply, Installation and Commissioning of an external DC Power Supply System, MW or IP
Transmission. Removal of Existing LTE BTS except RRHs,

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 58 of 67
Issue 2013-02-08 printed: December 11, 2013


48. 00001347 I diplexer
Installation of one diplexer on the antenna line
Service
Installation of additional fixing material for the diplexer (in case of pole mounting), such as steel
bands, etc.
Installation of diplexer with additional fixing material including connection to the antenna line
(only if RF feeder exists) with waterproofing.
Installation of one additional jumper with fixing materials, and labels including installation of
waterproofing (only if diplexer placed close to the antenna).
Installation of two additional jumper with fixing materials and labels including installation of
waterproofing (only if diplexer placed close to the Base Stetion).
Installation of label for the diplexer.
Material
Excludes
Commisioning of antenna line and antenna
Installation of more than one diplexer.
Installation of antenna line including other active and passive components.
Special cases and other requirements
If the antenna line is installed in the same time like the diplexer, the installation of waterproofing
for the RF feeder-diplexer connector as well as termination of the RF feeder to the diplexer are
part of the antenna line installation.
Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark
1 Jumper
Installation
100% 2 pcs DNxxx Incl. Labeling
2 Diplexer
Installation
100% 1 pcs DNxxx Inc. fixing &
labeling

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 59 of 67
Issue 2013-02-08 printed: December 11, 2013


49. 00001504 Rem MHA-TMA
Removal and packing of one Mast Head Amplifier / Tower Mounted Amplifier
Service
Blocking of the affected sector in the Base Station.
Reconfiguration of Base Station.
Disconnection and removal of the grounding cable including fixing in the defined length.
Removal of waterproofing from connectors.
Removal of one jumper cable between MHA/TMA and antenna including cable fixing.
Disconnection of feeder cables from MHA/TMA.
Installation of connector covers (caps) to the antenna connector and the feeder connectors, or
termination of feeder cables to the antenna and installation of new waterproofing.
Removal and packaging of MHA/TMA including mounting brackets, accessories and applying of
MHA/TMA connector covering (caps).
Re-commissioning of the antenna line (if applicable).
Collecting of the removed items in a designated area at the site.
Material
Excludes
Removal of any other active or passive components of the antenna line.
Removal of more than one MHA/TMA.
Removal of Bias Tee.
Special cases and other requirements
The supply of connector covers (caps) to the antenna connector and the feeder connectors, or
termination of feeder cables to the antenna and supply of new waterproofing is also included in
this Service Item.
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 BS
Reconfiguration
100% 1 pcs DNxxx Incl. sector block,
reconf.
2 Removal of Cable 100% 7 m DNxxx MHA gnd cable
3 Removal of
Jumper
100% 0.5 m DNxxx Incl. fixing, labels
100% 1.5 m DNxxx Incl. fixing, labels
4 Removal of MHA 100% 1 pcs DNxxx Incl. pack,
waterproofing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 60 of 67
Issue 2013-02-08 printed: December 11, 2013


50. 00001509 Rem omni or panel antenna up to 2m
Removal of omni or panel RF antenna of the size up to 2 meters
Service
Blocking of the affected antenna (sector) in the Base Station.
Disconnection and removal of the grounding cable (if applicable).
Removal of waterproofing from connectors antenna connectors.
Disconnection of feeder cables.
Installation of waterproofing materials for temporary sealing of feeder connectors (if applicable).
Removal and packaging of antenna including mounting brackets and tilting kits
Collecting of the removed items in a designated area at the site.

Material
Excludes
Removal of any other type of antenna bigger than 2m.
Removal of jumper or antenna line.

Special cases and other requirements
The supply of waterproofing materials for temporary sealing of feeder connectors (if applicable)
is also included in this Service Item (if applicable).

Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 Antenna (Sector)
Blocking
100% 1 pcs DNxxx
2 Cable Removal 100% 7 m DNxxx Ant. gnd cable
3 RF Ant.
Deinstallation
100% 1 pcs DNxxx > 2m incl pack, temp
waterp.

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 61 of 67
Issue 2013-02-08 printed: December 11, 2013


51. 00007508 M floor mount 19-23 open frame
Material for floor-standing 19-23 inch open frame
Service
Material
Supply of a floor-standing open 19 or 23 inch frame with floor fixing material and label.
Supply of an AC power distribution strip for the 19 or 23 inch frame with mounting material.
Supply of AC power cable with fixing material and labels up to the defined length.
Supply of DC power cable with fixing material, labels and connectors (lugs) up to the defined
length.
Supply labels for AC power breaker and ground termination point (bus bar port).
Supply of the grounding cable up to the defined length including labeling of the ground
termination point.
Excludes
Installation material for DC power distribution or frame enclosures.
Special cases and other requirements
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 19/23inch Frame 100% 1 pcs CS75064.00 Floor-standing
2 19/23inch Frame Fixing 100% 4 pcs CSxxx Bolt
100% 4 pcs CSxxx Washer
100% 4 pcs CSxxx Anchor
3 19/23inch Frame AC Strip 100% 1 pcs CSxxx AC strip, 6 sockets
4 19/23inch AC Strip Mount
Material
100% 4 pcs CSxxx Bolt
100% 4 pcs CSxxx Washer
100% 4 pcs CSxxx Nut
5 Power Cable Complete 100% 7 m CSxxx AC/DC power cable
100% 0.1 m CS73327.12 Shrink sleeve
100% 1 pcs CSxxx AC plug
100% 0.3 pcs CS73320.01 Cable tie, 100pcs
6 Ground Cable Complete 100% 7 m CSxxx Grounding cable max.
3m
100% 2 pcs CSxxx Gnd cable lug
100% 0.2 m CS73327.12 Shrink sleeve
100% 0.3 pcs CS73320.01 Cable tie, 100pcs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 62 of 67
Issue 2013-02-08 printed: December 11, 2013


7 Label 100% 2 pcs CSxxx AC/DC cable label
100% 0 pcs CS73320.01 Cable tie, 100pcs
100% 2 pcs CSxxx Grounding cable label
100% 0 pcs CS73320.01 Cable tie, 100pcs
100% 1 pcs CSxxx Circuit braker label
100% 1 pcs CSxxx Gnd point lable
100% 1 pcs CSxxx 19-frame label

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 63 of 67
Issue 2013-02-08 printed: December 11, 2013


52. 00038286 I floor mount 19-23 open frame
Installation of floor-standing 19-23 inch open frame
Service
Installation of a floor-standing open 19 or 23 inch frame with floor fixing material and label.
Installation of an AC power distribution strip for the 19 or 23 inch frame with mounting material.
Installation of AC power cable with fixing material and labels up to the defined length.
Installation of DC power cable with fixing material, labels and connectors (lugs) up to the defined
length.
Installation labels for AC power breaker and ground termination point (bus bar port).
Installation of the grounding cable up to the defined length including labeling of the ground
termination point.
Material
Excludes
Installation of DC power distribution or frame enclosures.
Special cases and other requirements
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 19/23inch Frame Installation 100% 1 pcs DNxxx Floor-standing
2 19/23inch Frame AC Strip
Install.
100% 1 pcs DNxxx
3 Grounding Cable Installation 100% 10 m DNxxx Incl. labeling & testing
4 AC/DC Power Cable
Installation
100% 20 m DNxxx Incl. labeling & testing

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 64 of 67
Issue 2013-02-08 printed: December 11, 2013


53. 00007509 M floor mount 19-23 cab
Material for floor mount 19-23 inch cabinet
Service
Material
Supply of a floor-standing 19 or 23 inch cabinet with floor fixing material and label.
Supply of an AC power distribution strip for the 19 or 23 inch cabinet with mounting material.
Supply of AC power cable with fixing material and labels up to the defined length.
Supply of DC power cable with fixing material, labels and connectors (lugs) up to the defined
length.
Supply labels for AC power breaker and ground termination point (bus bar port).
Supply of the grounding cable up to the defined length including labeling of the ground
termination point.

Excludes
Supply of DC power distribution frame.

Special cases and other requirements
Bill of Quantities
Pos Category Occurrence Qnt Unit Component Remark
1 19-23 inch Cabinet 100% 1 pcs CS75054.50 Floor-standing
2 19-23 inch Cabinet Fixing 100% 4 pcs CSxxx Bolt
100% 4 pcs CSxxx Washer
100% 4 pcs CSxxx Anchor
3 19-23 inch Cabinet AC Strip 100% 1 pcs CSxxx AC strip, 6 sockets
4 19-23 inch Cabinet AC Strip
Mount Material
100% 4 pcs CSxxx Bolt
100% 4 pcs CSxxx Washer
100% 4 pcs CSxxx Nut
5 Power Cable Complete 100% 20 m CSxxx AC power cable
100% 0.1 m CS73327.12 Shrink sleeve
100% 1 pcs CSxxx AC plug
100% 0.3 pcs CS73320.01 Cable tie, 100pcs
6 Ground Cable Complete 100% 10 m CSxxx Grounding cable max.
3m
100% 2 pcs CSxxx Gnd cable lug
100% 0.2 m CS73327.12 Shrink sleeve
100% 0.3 pcs CS73320.01 Cable tie, 100pcs
7 Label 100% 2 pcs CSxxx AC cable label
100% 0 pcs CS73320.01 Cable tie, 100pcs

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 65 of 67
Issue 2013-02-08 printed: December 11, 2013


100% 2 pcs CSxxx Grounding cable label
100% 0 pcs CS73320.01 Cable tie, 100pcs
100% 1 pcs CSxxx Circuit braker label
100% 1 pcs CSxxx Gnd point lable
100% 1 pcs CSxxx Cabinet label

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 66 of 67
Issue 2013-02-08 printed: December 11, 2013


54. 00073254 Implementation BTS Modules Re-arrangement
Re-arrangement of existing Flexi BTS modules within the existing cabinet
Service
Travel of Implementation teams to the site
Preparation for re-arrangement of modules including planning for MDT,BTS shut-down or sector
blockage etc.
Removal and re-installation of modules along with all the cabling, labeling work
Re-arrangement of all the internal cable on site
Re-arrangement and replacement of all the jumpers if required .
VSWR and Return Loss measurement for jumpers if required
Powering-up of the Base Station or un-block the sector if required.
Clear all the HW snags from the Punch List
Any other related work required on site for complete Implementation
All the coordination with NSN and Mobily staff to complete the Implementation work
Excludes
Any new HW installation

Copyright 2009 , Nokia Siemens Networks
All rights reserved.

Service Item Appendix Page 67 of 67
Issue 2013-02-08 printed: December 11, 2013


55. 00073255 BTS Modules Removal and Installation
Removal for BTS RF modules from one site and Re-installation on another site
Service
Travel of Implementation teams to both the sites
Site survey of sites and preparation of all the related documents for the sites as part of site folder
for site acceptance.
Preparation for Removal and Re-installation of modules including planning for MDT,BTS shut-
down or sector blockage etc.
Removal of spare RF modules from 2G sites which have been downgraded by re-farming
Transport of modules from site to WH or new site
Re-installation of RF modules at new site where UMTS900 is to be installed
Installation and fixing of Flexi base station plinth on floor if required.
Installation of grounding cable for the Flexi base station plinth with fixing accessories (cable
ties), labels and connectors (lugs) up to the required length including testing of the complete
cable run.
Installation of Flexi base station RF modules including casing, fixing of earthquake protection
screws, front and back covers if applicable.
Installation of grounding cable between Flexi base station RF module and Flexi base station
plinth or the nearest grounding point with fixing accessories (cable ties) including testing of the
complete cable run if applicable.
Installation of delivered internal power cabling between Flexi base station RF modules and
system module, including fixing accessories (cable ties).
Installation of delivered internal databus cabling between Flexi base station RF module and
system module, including cleaning of optical connectors and fixing accessories (cable ties).
Preparation and Installation of Jumpers (including clamps and Weather proofing) as required on
site from the RF module to the Antenna.
Testing of the Jumpers (VSWR etc) if required and attach test report.
Installation of RDSA cables and FO cables between 2G and 3G modules as per given site
configuration
Re-configuration / Re-commissioning of existing 2G BTS if required
Azimuth and Tilt Adjustment for antennas if required on site.
Conduct PAT, prepare and submit all PAT documents and Clear all the HW snags from the
Punch List
Any other related work required on site for complete Implementation
All the coordination with NSN and Mobily staff to complete the Implementation work

Vous aimerez peut-être aussi