Vous êtes sur la page 1sur 28

SUNANDA

SPECIALITY COATINGS PVT.LTD.


BILL OF QUANTITIES






























INDIA U.S.A. U.A.E. TANZANIA GHANA KENYA
ETHIOPIA MALDIVES NEPAL AFGHANISTAN RUSSIA OMAN
CONCRETE MATERIALS CONSULTANCY DIVISION
Satyadham, Road No. 2, Sion (E),
Mumbai 400 022, India
Tel: +91-22-24034130 / Fax: +91-22-24034133

Email : info@sunandaglobal.com
Website : www.sunandaglobal.com




Consultants for Building Materials
Manufacturers of Construction Chemicals since 1979
ISO 9001:2008

2
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

I N D E X

Sr. No. PARTICULARS
Pg No
A.
SPECIALISED ADMIXTURES FOR PCC & RCC WORKS
1. Integral Waterproofing Admixture for PCC Works
4
2. Superplasticisers for RCC Members
4
3. Integral Corrosion Inhibiting Admixture for RCC Members
5
4. Protection to Foundation from Chloride Attack.
5
Option 1 - Tar Modified Epoxy Coating For Foundation Protection

Option 2 Polymer Modified Bitumous Coating For Foundation Protection

5. Repairs of Honeycombed Concrete
6
B. EXTERNAL APPLICATIONS

6. External Crackless Plaster
7
7. Waterproofing of Dead Walls
7
8.
100% Acrylic, Decorative, Waterproof And Heat Insulating Paint For External
Walls
8
9. Textured Paint/ Finish
9
10. Treatment to Tie- Rod Hole On Mivan Shuttering Walls
9
C.
WATERPROOFING TREATMENT TO VARIOUS AREAS
11. Podium Waterproofing

Waterproofing Treatment to Softscape Area
10-11
Waterproofing & Anti-Rooting Treatment To Planter Boxes
11
Waterproofing Treatment to Hardscape Area
11-12-13
12. Waterproofing Treatment of Water bodies
13-14
13. Waterproofing Treatment to R.C.C. Terrace Slab
14-15
14. Waterproofing Treatment to Toilet Blocks
16-17
15. Waterproofing Treatment to O.H.W.T.
17-18
16. Waterproofing Treatment to RCC Bore Packing
19

SUNANDAS PRESENCE

3
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY


D.
DIFFERENT TYPES OF BONDING AGENT
17. Bonding Agent for C.M. Plaster with RCC Surface 20
18. Bonding Agent for RCC Construction Joints 20
19. Bonding Agent for Gypsum Plaster 20
20. Bonding Agent for Tile Fixing. 21
E.
VARIOUS COATINGS & APPLICATION FOR CAR PARKING AREAS
21. Anti-Carbonation Coating
22
22. Epoxy Coating
22
23. Non-Metallic Floor Hardeners
23
Option1 : Dust Proof Liquid Floor Hardener

Option2: Dry Shake Floor Hardener

24. Hygienic Coating for Water Tanks
23
F.
ANTI-CORROSIVE TREATMENT TO STEEL
25. Rust Removal and Conversion for Steel
24
26. Rust Passivation of Steel
24
27. Corrosion Protection to Steel With Sacrificial Anode -SUNANODE
24
28. Integral Corrosion Inhibiting Admixture
25
29. PU Coating For Protection to Structural Steel/ Railings/ Grills
25
G.
ANCHORING OF DOWEL BARS
30. Anchoring Dowel Bars in RCC Members Using Epoxy Grouts
26
31. Rock Anchoring for Foundations/Rafts Using Microconcrete
26
H. CURING COMPOUNDS

32. Curing Compounds
27
I. EPOXY FLOORING

33a 1mm Self Levelling Epoxy flooring
28
33b 2mm Self Levelling Epoxy flooring
28
33c 3mm Epoxy Screed + Self Levelling Epoxy flooring
28






4
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
Sr. No Description of Works Qty Per Rate
Rs.
Amount
Rs.
A. SPECIALISED ADMIXTURES FOR PCC & RCC WORKS
1. INTEGRAL WATERPROOFING ADMIXTURE FOR PCC WORKS
A Providing and laying P.C.C. in designed grade at all
heights and levels on well compacted/sound
surfaces using a mechanical mixer including
dewatering, shuttering, vibrating, curing and
finishing as required. Admix POLYTANCRETE IWL of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent. It is to be added directly to the gauging
water @200 ml per bag of cement. The rate to
include for storage, handling, transportation of all
materials, equipments, providing material test
reports of Cement/Sand/Aggregates/Water from
manufacturer and approved testing agencies,
casting- curing and testing of concrete cubes @
three cubes/100 cum of concrete pour, etc. all
complete to the satisfaction of the EIC













Cu. m





2. SUPERPLASTICISERS FOR RCC MEMBERS
A
Providing and laying R.C.C. of designed grade at all
heights and levels on well compacted/sound
surfaces using a mechanical mixer including
dewatering, shuttering, vibrating, curing and
finishing as required. Admix superplasticiser
POLYTANCRETE SPR of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent @ 150ml-200 ml per
bag of cement The rate to include for storage,
handling, transportation of materials, equipments
etc using appropriate methods etc. complete.










a) For Footings and other foundation works Cu.m
b) For Columns at all levels

Cu.m
c) For Beams at all levels.

Cu.m
d) For Slabs at all levels Cu.m



5
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
3. INTEGRAL CORROSION INHIBITING ADMIXTURE FOR RCC MEMBERS

Providing and laying R.C.C. of designed grade at all
heights and levels on well compacted/sound
surfaces using a mechanical mixer including
dewatering, shuttering, vibrating, curing and
finishing as required. Admix integral corrosion
inhibitor POLYALK CP293 of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent @ 0.5 to 1% by
weight of cement depending on amount of chloride
present. The rate to include for storage, handling,
transportation of materials, equipments etc using
appropriate methods etc. complete.
Cu.m

4. PROTECTION TO FOUNDATION FROM CHLORIDE ATTACK.
Option 1 - Tar modified epoxy coating for foundation protection
A Providing and applying two coats of protective
membrane over the cured concrete surface like RCC
footings, columns, plinth beams etc. which will be
submerged under soil so as to protect the same.
Apply two pack coal tar epoxy system of SUNEPOXY
COAL TAR of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent.Mix Part A and Part B of
SUNEPOXY COAL TAR in 1:1 ratio with slow speed
stirrer and apply the same on a clean RCC surface by
brush. Allow to set for 8-10 hours and apply the
second coat. The rate to include for application at all
levels to various RCC elements to the satisfaction of
the EIC etc. complete.













Sq. m

Option 2 Polymer modified bituminous coating for foundation protection
B Providing and applying coats of polymerized
bituminous coating of POLYALK WPB over the cured
concrete surface like RCC footings, columns, plinth
beams etc. which will be submerged under soil so as
to protect the same. Apply a primer coat of POLYALK
WPB with equal amount of water. Prime surface
should be allowed to dry for 24 hrs. Apply a coat of
POLYALK WPB in a continuous unbroken film. Allow
to set for 24 hours and apply the second coat. Avoid
pinholes The rate to include for application at all
levels to various RCC elements to the satisfaction of
the EIC etc. complete.










Sq.m



6
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY


5. REPAIRS TO HONEYCOMBED SURFACE
Clean & chip off the damaged and honeycombed RCC
portion etc. Moisten the surface and apply bonding coat
of POLYALK EP of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent to the entire honeycombed concrete
surface. Hand pack Polymer Modified Mortar by mixing
1 part by weight of POLYALK EP
5 parts by weight of cement
15 parts by weight of well graded sand and water to
achieve the desired consistency
At a time apply mortar layer not more than 15-20 mm
thick. The mortar should be prepared using mechanical
mixers / stirrers & should be well compacted and
finished using appropriate methods. If the thickness of
mortar required to make up the concrete section is
more; then repeat above procedure. The rate to include
for necessary compaction with mechanical plate vibrator
etc. complete to the satisfaction of the EIC. Payment will
be made on the quantity of POLYALK EP consumed.


















Litrs



7
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
B. EXTERNAL APPLICATIONS
6. EXTERNAL CRACKLESS PLASTER


Providing and applying 20-25 mm thick sand faced
cement plaster to external surfaces in two coats with
first coat in 12-15 mm thick in 1:4 C.M and second coat
in 8-10 mm thick in C.M 1:4 finished in proper line and
level. Add in both the coats shrinkage compensating
admixture cum plasticizer-SUNPLEX 330 gms pouch of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
per 50 Kg bag of cement. Add SUNPLEX in dry machine
mix before addition of gauging water. The rate to
include for drip moulds, grooves, bands, watas at all
heights including necessary curing etc. complete.












Sq.m




7. WATERPROOFING OF DEAD WALLS

Clean the receiving plastered surface of all loose
particles, dirt & rub down to original hard surface.
Inspect for cracks if any, and clean and moisten them.
Define the crack with sharp edge tool. Providing and
applying ready to use acrylic polymeric non-shrink auto-
suction putty POLYFILL-AR of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent on the crack
and finish at all heights, level etc. complete. After 24
hours inspect and if required as a result of auto-suction,
provide another filling over the same.
Provide and apply 2 coats of POLYALK WP & cement in
1:1 proportion by weight in slurry form on the entire
dead walls of the building. Prepare a slurry using 1 part
by weight of POLYALK WP and 1 part by weight of fresh
cement (white) (Do not add any water). Mixing is best
done using a low-speed stirrer. Keep the mix
continuously stirred so as to ensure brushable
consistency. Air cure for 24 hrs for initial setting and
then by sprinkling water for 3 days. The rate includes
erection of scaffolding at all levels, applying coating,
curing etc. all complete as per the satisfaction of the EIC.


















Sq.m







8
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY




8
100% ACRYLIC, DECORATIVE , WATERPROOFING & HEAT INSULATING EXTERNAL PAINT

A

Clean the receiving plastered surface of all loose
particles, dirt & rub down to original hard surface.
Inspect for cracks if any, and clean and moisten them.
Define the crack with sharp edge tool. Providing and
applying ready to use acrylic polymeric non-shrink auto-
suction putty POLYFILL-AR of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent on the crack
and finish at all heights, level etc. complete. After 24
hours inspect and if required as a result of auto-suction,
provide another filling over the same. Provide and apply
a coat of POLYALK WP & cement in 1:1 proportion by
weight in slurry form on the crackfilled area



B

Providing and applying 100% acrylic, heat insulating and
decorative external acrylic coating SUNEXT-8 of M/s.
Sunanda Speciality Coatings Pvt. Ltd. or equivalent or
equivalent or equivalent of approved shade. Mix 1 litre
of SUNEXT-8 with 1 L of water and use as priming coat
on the surface. Mix 1 L of Sunext-8 with 400-500 ml of
water, stir well and apply by brush for subsequent two
coats. The process includes erection of scaffolding at all
levels, applying three coats at an interval of 4-6 hours
between each coat. Cure as normal etc. all complete as
per the satisfaction of the EIC











Sq.m



9
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
9. TEXTURED PAINT/ FINISH

Clean the existing surface by scrubbing so as to remove
all the dust, dirt, grime, oil etc and washing the surface
clean with jet of water etc. complete to the satisfaction
of the EIC. Apply textured coat- POLYTEXT FINISH of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
using flat trowel at a thickness of 1.5-2 mm and
repeat trowel on the spread material in one direction
only till desired finish is obtained. Remove the excess
POLYTEXT FINISH before material has set. Cure applied
material for 12 - 16 hours prior to application of exterior
paint. The rate includes erection of scaffolding at all
levels, applying texture finish, curing etc. all complete as
per the satisfaction of the EIC.















Sq. m


10. TREATMENT TO TIE- ROD HOLE ON MIVAN SHUTTERING WALLS

Clean the tie rod hole on the RCC surfaces and remove
dust, loose particles, etc. Apply bonding coat slurry of
POLYALK EP of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent to the entire surface. Provide Hand
pack Polymer Modified Mortar within 10 to 15 minutes
i.e. (wet on wet) as per following specifications using :
2 part by weight of POLYALK EP
5 parts by weight of cement
15 parts by weight of well graded sand
The mortar should be prepared using mechanical
mixers/stirrers and should be well compacted and
finished using appropriate methods. The rate to include
for erecting necessary scaffolding, curing etc complete
to the satisfaction of the EIC.














Nos



10
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
C. WATERPROOFING TREATEMENT TO VARIOUS AREAS
11
PODIUM WATERPROOFING
A WATERPROOFING TREATMENT TO SOFTSCAPE AREA
1
Clean the existing surface for waterproofing treatment
of Podium slab by removing dust, dirt, loose particles,
cement laitance etc. using Floor Polishing Machine.
Drilling holes at construction joints and identify
damaged/honeycombed of the concrete surface and
fixing PVC nozzles at 2-3 ft c/c and sealing the same with
PMM, then total area to be filled with water minimum
6 deep for minimum 3 days, after 3 days of ponding
slab shall be checked for leakage/ seepage even
dampness and such area shall be marked and pressure
grouting / crack filling shall be done, Identifying the
cracks, construction joints & filling the same with
Polymer Modified Mortar using POLYALK EP. Injection
grouting shall be done with providing and injection non
shrink cementations grout by mixing 2 pouches (330
gms. Each) of SUNPLEX of M/s. Sunanda Speciality
Coatings Pvt.Ltd. or equivalent and 50 kgs of cement and
sufficient water for flow ability, Grouting the same
under pressure in pre-drilled holes by grouting pump
etc. complete. After grouting is completed after 24
hours, cut the nipples and seal it with PMM etc.
complete. After completion of crackfilling & grouting
again ponding shall be done for 3 days to ensure the
success of pressure grouting, if there is no leakages/
seepage/ dampness then only further activities shall be
started. Providing and applying three coats of POLYALK
WP of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent by mixing it in cement in 1:1.25 ratio by
weight at an interval of 24 hours. Using mechanical
stirrer for mixing.
Finally, providing and applying single coat of bonding
agent HACK-AID-PLAST of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent and providing wet on
wet a cement mortar screed of 1:4 cement mortar in 12-
15 mm thickness. Air cure the same for 24 hrs and
thoroughly curing by filling water for 7 days, by making
6 vattas.




11
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

2

Providing and laying thick soaked brick bat coba in CS
Mortar 1:3 to proper level and slope, curing shall be
done with filling of water for 48 hrs fill up the BBK joints
and lay metal coba in CM 1:3 by adding SUNPLEX and
making 6 vattas on the junctions of wall and floor
keeping surface rough for further tiling. Curing to be
done for minimum 7 days. by filling water with vataas,
then final inspection shall be carried out to ensure that
there are no damp patches, leakages, seepages etc at
lower slab., if any type of leakages, seepages damp
patches are found, in that case same shall be repaired /
part shall be redone as per requirement. Rate to include
for making side watta in PMM, ponding for seven days
by closing the outlets etc. complete to the satisfaction of
the EIC. Further finishing as per requirement.



3

Sealing the cutouts in the slab and the pipes passing
through the terrace floor by filling PMM/Micro-
concrete.






Nos

B. WATERPROOFING & ANTI-ROOTING TREATMENT TO PLANTER BOXES
After above waterproofing application gets over as
above for planter boxes. Smoothening and proper curing
of IPS is done, mix 30% anti-rooting solution of SUN-
ANTIFUNGAL of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent in water homogenously.
Provide and apply first coat of anti-rooting coating of
SUN- ANTIFUNGAL mixed with water by brush on the
cured dash coat.
Apply a second coat & third coat of SUN-ANTIFUNGAL
over the first coat by maintaining 3-4 hours time
interval.
Proceed with earth filling etc.










Sq. m











C. WATERPROOFING TREATMENT TO HARDSCAPE AREA
1 Clean the existing surface for waterproofing treatment
of Podium slab by removing dust, dirt, loose particles,
cement laitance etc. using Floor Polishing Machine.
Drilling holes at construction joints and identify
damaged/honeycombed of the concrete surface and
fixing PVC nozzles at 2-3 ft c/c and sealing the same with














12
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
PMM, then total area to be filled with water minimum
6 deep for minimum 3 days, after 3 days of ponding
slab shall be checked for leakage/ seepage even
dampness and such area shall be marked and pressure
grouting / crack filling shall be done, Identifying the
cracks, construction joints & filling the same with
Polymer Modified Mortar using POLYALK EP. Injection
grouting shall be done with providing and injection non
shrink cementations grout by mixing 2 pouches (330
gms. Each) of SUNPLEX of M/s. Sunanda Speciality
Coatings Pvt.Ltd. or equivalent and 50 kgs of cement and
sufficient water for flow ability, Grouting the same
under pressure in pre-drilled holes by grouting pump
etc. complete. After grouting is completed after 24
hours, cut the nipples and seal it with PMM etc.
complete. After completion of crackfilling & grouting
again ponding shall be done for 3 days to ensure the
success of pressure grouting, if there is no leakages/
seepage/ dampness then only further activities shall be
started. Providing and applying two coats of POLYALK
WP of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent by mixing it in cement in 1:1.25 ratio by
weight at an interval of 24 hours. Using mechanical
stirrer for mixing.
Finally, providing and applying single coat of bonding
agent HACK-AID-PLAST of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent and providing wet on
wet a cement mortar screed of 1:4 cement mortar in 12-
15 mm thickness. Air cure the same for 24 hrs and
thoroughly curing by filling water for 7 days, by making
6 vattas of the EIC. Further finishing as per
requirement.



























Sq. m





2

Providing and laying 4 thick soaked brick bat coba in
CS Mortar 1:3 to proper level and slope, curing shall be
done with filling of water for 48 hrs fill up the BBK joints
and lay metal coba in CM 1:3 by adding SUNPLEX and
making 6 vattas on the junctions of wall and floor
keeping surface rough for further tiling. Curing to be
done for minimum 7 days. by filling water with vataas,
then final inspection shall be carried out to ensure that
there are no damp patches, leakages, seepages etc at
lower slab., if any type of leakages, seepages damp


13
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
patches are found, in that case same shall be repaired /
part shall be redone as per requirement. Rate to include
for making side watta in PMM, ponding for seven days
by closing the outlets etc. complete to the satisfaction of
the EIC. Further finishing as per requirement.

3 Sealing the cutouts in the slab and the pipes passing
through the terrace floor by filling PMM/Micro-
concrete.





Nos


12. WATERPROOFING TREATMENT TO WATERBODIES
1. Clean the RCC side walls and base slab surface for
treatment by removing dust, dirt and layers of concrete
over the surface. etc. using Floor Polishing Machine.
Drilling holes at construction joints and identify
damaged/honeycombed of the concrete surface and
fixing PVC nozzles at 2-3 ft c/c and sealing the same with
PMM, then total area to be filled with water minimum
6 deep for minimum 3 days, after 3 days of ponding
slab shall be checked for leakage/ seepage even
dampness and such area shall be marked and pressure
grouting / crack filling shall be done, Identifying the
cracks, construction joints & filling the same with
Polymer Modified Mortar using POLYALK EP. Injection
grouting shall be done with providing and injection non
shrink cementations grout by mixing 2 pouches (330
gms. Each) of SUNPLEX of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent and 50 kgs of cement
and sufficient water for flow ability, Grouting the same
under pressure in pre-drilled holes by grouting pump
etc. complete. After grouting is completed after 24
hours, cut the nipples and seal it with PMM etc.
complete. After completion of crackfilling & grouting
again ponding shall be done for 3 days to ensure the
success of pressure grouting, if there is no leakages/
seepage/ dampness then only further activities shall be
started. Providing and applying three coats of POLYALK
WP of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent and cement in 1:1.25 ratio at an interval of
24 hours on the slab and side walls. Apply two coats and
sure the same and apply the third coat and while it is
still wet and tacky providing wet chat/dash coat of 1:4
cement mortar in 10-12 mm thickness.






























Sq. m



14
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

2. Lay on the slab an average 2 thick well soaked brick
bat metal coba in cement mortar 1:4 to proper level and
slope as per instructions adding SUNPLEX - 330 gms
pouch of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent or equivalent or equivalent per 50 Kg bag of
cement to the mortar mix.
Fill up the brick joints and lay metal coba in C:M 1:4
adding SUNPLEX- 330 gms pouch of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent per 50 Kg bag
of cement and finished with further provision of floor
tiles. Rate to include for making side watta in PMM,
ponding for seven days by closing the outlets etc.
complete to the satisfaction of the EIC. Further finishing
as per requirement.













Sq. m












13. WATERPROOFING TREATMENT TO R.C.C. TERRACE SLAB

A

Clean the RCC terrace slab surface for treatment by
removing dust, dirt and layers of concrete over the
surface. etc. using Floor Polishing Machine. Drilling holes
at construction joints and identify
damaged/honeycombed of the concrete surface and
fixing PVC nozzles at 2-3 ft c/c and sealing the same with
PMM, then total area to be filled with water minimum
6 deep for minimum 3 days, after 3 days of ponding
slab shall be checked for leakage/ seepage even
dampness and such area shall be marked and pressure
grouting / crack filling shall be done, Identifying the
cracks, construction joints & filling the same with
Polymer Modified Mortar using POLYALK EP. Injection
grouting shall be done with providing and injection non
shrink cementations grout by mixing 2 pouches (330
gms. Each) of SUNPLEX of M/s. Sunanda Speciality
Coatings Pvt.Ltd. or equivalent and 50 kgs of cement and
sufficient water for flow ability, Grouting the same
under pressure in pre-drilled holes by grouting pump
etc. complete. After grouting is completed after 24
hours, cut the nipples and seal it with PMM etc.
complete. After completion of crackfilling & grouting
again ponding shall be done for 3 days to ensure the
success of pressure grouting, if there is no leakages/
seepage/ dampness then only further activities shall be






















































15
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
started.
Providing and applying two coats of POLYALK WP of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
and cement in 1:1.25 ratio at an interval of 24 hours on
the chajjas and extending it upto 10 over the side
walls. Air cure the same for 24 hours and damp cure for
next 4-5 days. Providing and applying single coat of
bonding agent HACK-AID-PLAST of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent on the
POLYALK WP coating by spray and providing wet on wet
a chat/dash coat of 1:4 cement mortar in 10-12 mm
thickness.
All mortar mix to be necessarily added with SUNPLEX
330 gms pouch of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent or equivalent or equivalent per 50 Kg
bag of cement. All coats of POLYALK WP to be inspected
using a Magnifying glass by the EIC to satisfaction to
ensure pinhole free coating. Ensure mechanical mixing
of POLYALK WP and cement slurry using stirrers and
check that cement particles do not settle down in the
prepared mix. Consume the prepared mix within 30
minutes. Payment will be made as per the plan area.




















Sq.m




B Lay small sized well soaked brick bat metal coba in
cement mortar 1:3 to proper level and slope as per
instructions adding SUNPLEX - 330 gms pouch of M/s.
Sunanda Speciality Coatings Pvt. Ltd. or equivalent or
equivalent or equivalent per 50 Kg bag of cement to the
mortar mix.
Fill up the joints and lay I.P.S adding SUNPLEX- 330 gms
pouch of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent per 50 Kg bag of cement to the cement
mortar 1:3 mixed and finished smooth with neat cement
on top so as to drain water smoothly. Make chequered
markings with a grid of 24X 24.
Provide about 9 to 12 watta along the walls with
cement mortar 1:3 small brick bats and IPS finish on the
top. Rate to include for making border at the junction of
watta and wall plaster, ponding for seven days by
closing the RW outlets and making watas etc. complete
to the satisfaction of the EIC.




















Sq.m



16
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

C.

Providing and applying china mosaic chips over the
surface of approved make and selected design over the
I.P.S surface, vatas etc in cement mortar bedding
including cleaning, acid washing etc. complete to the
satisfaction of the EIC. Add SUNPLEX- 330 gms pouch
of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent per 50 Kg bag of cement to the cement
mortar bedding.








Sq.m



14. WATERPROOFING TREATMENT TO TOILET BLOCKS
A Clean the RCC slab surface & wall for treatment by
removing dust, dirt and layers of concrete over the
surface. etc. by mechanical means. Drilling holes at
construction joints and identify damaged/honeycombed
of the concrete surface and fixing PVC nozzles at 2-3 ft
c/c and sealing the same with PMM, then total area to
be filled with water minimum 6 deep for minimum 3
days, after 3 days of ponding slab shall be checked for
leakage/ seepage even dampness and such area shall be
marked and pressure grouting / crack filling shall be
done, Identifying the cracks, construction joints & filling
the same with Polymer Modified Mortar using POLYALK
EP. Injection grouting shall be done with providing and
injection non shrink cementations grout by mixing 2
pouches (330 gms. Each) of SUNPLEX of M/s. Sunanda
Speciality Coatings Pvt.Ltd. or equivalent and 50 kgs of
cement and sufficient water for flow ability, Grouting
the same under pressure in pre-drilled holes by grouting
pump etc. complete. After grouting is completed after
24 hours, cut the nipples and seal it with PMM etc.
complete. After completion of crackfilling & grouting
again ponding shall be done for 3 days to ensure the
success of pressure grouting, if there is no leakages/
seepage/ dampness then only further activities shall be
started.
Providing and applying two coats of POLYALK WP of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
and cement in 1:1.25 ratio at an interval of 24 hours on
the terrace slab and extending it upto 10 over the
F.F.L. Air cure the same for 24 hours and damp cure for
next 4-5 days.
Providing and applying single coat of bonding agent


































17
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
HACK-AID-PLAST of M/s. Sunanda Speciality Coatings
Pvt. Ltd. or equivalent on the POLYALK WP coating by
spray and providing wet on wet a chat/dash coat of 1:4
cement mortar in 10-12 mm thickness.
All mortar mix to be necessarily added with SUNPLEX
330 gms pouch of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent per 50 Kg bag of cement. All coats of
POLYALK WP to be inspected using a Magnifying glass
by the EIC to satisfaction to ensure pinhole free coating.
Ensure mechanical mixing of POLYALK WP and
cement slurry using stirrers and check that cement
particles do not settle down in the prepared mix.
Consume the prepared mix within 30 minutes. Payment
will be made as per the plan area.











Sq.m


B

Lay an average 2 thick well soaked brick bat metal
coba in cement mortar 1:4 to proper level and slope as
per instructions adding SUNPLEX - 330 gms pouch of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
or equivalent per 50 Kg bag of cement to the mortar
mix.
Fill up the brick joints and lay metal coba in C:M 1:4
adding SUNPLEX- 330 gms pouch of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent or equivalent
per 50 Kg bag of cement and finished with chequered
markings for further provision of floor tiles. Rate to
include for making border at the junction of watta and
wall plaster, ponding for seven days by closing the SWR
and soil outlets and making watas etc. complete to the
satisfaction of the EIC.















Sq.m

















15. WATERPROOFING TREATMENT TO O.H.W.T.
1. Clean the RCC slab surface & wall for treatment by
removing dust, dirt and layers of concrete over the
surface. etc. by mechanical means. Ensure that all bolt
holes and sleeving of pipe inserts have been completed
properly. Drilling holes at construction joints and
identify damaged/honeycombed of the concrete surface
and fixing PVC nozzles at 2-3 ft c/c and sealing the same
with PMM, then total area to be filled with water
minimum 6 deep for minimum 3 days, after 3 days of
ponding slab shall be checked for leakage/ seepage even
dampness and such area shall be marked and pressure













18
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
grouting / crack filling shall be done, Identifying the
cracks, construction joints & filling the same with
Polymer Modified Mortar using POLYALK EP. Injection
grouting shall be done with providing and injection non
shrink cementations grout by mixing 2 pouches (330
gms. each) of SUNPLEX of M/s. Sunanda Speciality
Coatings Pvt.Ltd. or equivalent and 50 kgs of cement and
sufficient water for flow ability, grouting the same under
pressure in pre-drilled holes by grouting pump etc.
complete. 24 hours after grouting is completed, cut the
nipples and seal it with PMM etc. complete. After
completion of crackfilling & grouting again ponding shall
be done for 3 days to ensure the success of pressure
grouting, if there is no leakages/ seepage/ dampness
then only further activities shall be started.
Providing and applying three coats of POLYALK WP of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
and cement in 1:1.25 ratio at an interval of 24 hours on
the slab and side walls. Apply two coats and cure the
same and apply the third coat and while it is still wet
and tacky providing wet chat/dash coat of 1:4 cement
mortar in 10-12 mm thickness.





















Sq.m

2. Lay Metal Coba in cement mortar in ratio1:3 by adding
SUNPLEX on the base floor with vata at wall & floor
junctions. On the side walls and ceiling provide double
coat CS 1:3 Plaster with appropriate chemicals agents
followed by curing for 7 days. All mortar mix to be
necessarily added with SUNPLEX 330 gms pouch of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
or equivalent per 50 Kg bag of cement. All coats of
POLYALK WP to be inspected using a Magnifying glass
by the EIC to satisfaction to ensure pinhole free coating.
Ensure mechanical mixing of POLYALK WP and cement
slurry using stirrers and check that cement particles do
not settle down in the prepared mix. Consume the
prepared mix within 30 minutes. Payment will be made
as per the plan area.














Sq.m









19
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
16 WATERPOOFING TREATMENT TO RCC BORE PACKING
Clean the Annular space around the pipe thoroughly;
make the concrete surface rough so as to create
bonding key for the micro-concrete to be placed.
Similarly roughen the surface of PVC pipe (the part
which is going into bore) using a rough file, wound 20
gauge GI wire around the pipe, Apply a bonding coat of
SUNEPOXY-368 (Resin 1 kg and Hardener 0.3 gms) &
after 20-30 minutes sprinkle sand layer on this portion
to make surface rough Apply one coat of POLYALK EP
the concrete and pipe surface & fill the annular space
with micro-concrete POLYCRETE A with proper
consistency and compact the same using proper tool,
leaving. After 24 hours fix the PVC nozzles in the groove
left and grout the same with cement using non shrink
cement grout prepared by mixing cement (50Kgs) and
SUNPLEX (330 gms pouch) as per standard
specifications. Cut the nozzles after grouting. Pond the
water and check for water tightness of the bore packing.
Rate to include cleaning, placing in position pipe sleeve,
application of bonding coat, preparation of Pipe sleeve,
pouring of POLYCRETE-A and curing at all height sand
levels etc. complete to the satisfaction of the EIC.




















Nos

















































20
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

D. DIFFERENT TYPES OF BONDING AGENT
17. BONDING AGENT FOR C.M. PLASTER WITH RCC SURFACE


Providing and applying one pack Bonding coat between
concrete members like RCC slabs, columns, beams,
Chajjas, pardis etc and cement mortar plaster using
HACK AID PLAST of M/s. Sunanda Speciality Coatings
Pvt. Ltd. or equivalent Clean the concrete surface
thoroughly to remove dust, dirt, grime, deshuttering oils
and rub down to a clean surface. Apply HACK AID PLAST
by spray on the entire concrete surface. Provide a lean
cement- sand dash coat over the same. Allow the dash
coat to set for around 24 hours. Further plastering as
per specifications can continue. The rate to include for
entire application at all heights and levels to the
complete satisfaction of the EIC.













Sq.m




18. BONDING COAT FOR CONSTRUCTION JOINTS IN CONCRETE
Providing and applying acrylic based polymeric Bonding
coat between concrete to concrete joint using POLYALK
EP of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent in the ratio by weight to the entire concrete
joint. Make sure that no area is left uncovered. The rate
to include application and ensuring poring of new
concrete maintaining sufficient tacky period of the
bonding coat, and application at all heights etc.
complete or as directed by the EIC.








Sq.m




19. BONDING AGENT FOR GYPSUM PLASTER
Providing and applying Gypsum plaster (of any standard
make) to the internal walls of the surface including
bonding agent HACK AID PLAST-G of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent
Apply HACK AID PLAST-G by brush/ roller or spray on
the surface. Provide Gypsum plaster over the same. All
complete as per the satisfaction of the EIC






Sq.m















21
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY



20. BONDING AGENT FOR TILE FIXING.
Providing and fixing polymerized cementitious ready to
use tile adhesive for fixing of tiles using POLYALK TA of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
.Add 20% of water by weight of POLYALK TA and lay the
same on the required area. Immediately place in
position the tile and tamp it to position so as to remove
the entrapped air and fix in position. Allow to set for 24
hours before proceeding with joint filling of the same.
The rate to include for cleaning, watering the entire
surface, laying and fixing in position of tiles at all levels
and heights to floors, walls, dado wherever necessary
etc. complete to the satisfaction of the EIC. Payment will
be made as per the plan area.












Sq.m


















































22
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

E. VARIOUS COATINGS & APPLICATION FOR CAR PARKING AREAS
21. ANTI CARBONATION COATING
A Clean the existing surface by scrubbing so as to remove
all the existing paint, dust, dirt, grime, oil etc and
washing the surface clean with jet of water etc.
complete to the satisfaction of the EIC.

B Providing and applying anti carbonation coating
SUNEXT-SP of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent of approved shade. Mix 1 litre of
SUNEXT-SP with 1 L of water and use as priming coat
on the surface. Mix 1 L of Sunext-8 with 100ml of water,
stir well and apply by roller for subsequent two coats.
The process includes erection of scaffolding at all levels,
applying three coats at an interval of 24 hours between
each coat curing etc. complete to the satisfaction of EIC








Sq.m


22. EPOXY COATING FOR CAR PARK AREAS


A

Clean the existing cured RCC surface so that it is free
from loose particles, flakes, grease, oil etc. and make
sure that the surface is dry & sound. Ensure to provide
necessary crack filling treatment if any on the existing
surface using epoxy mortar.
Mix SUNEPOXY 378 of M/s. Sunanda Speciality Coatings
Pvt. Ltd. or equivalent (resin and hardener in the ratio of
1:0.5 by weight) and apply by roller on the clean and dry
RCC surface. Allow to air cure for 24 hours and apply
similar two coats to achieve final finish. Rate includes
cleaning, treatment to existing cracks, application and
cleaning at all levels etc. complete to the satisfaction of
the EIC














Sq. m














23
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

23. NON-METALLIC FLOOR HARDENERS
OPTION 1: DUST PROOF LIQUID FLOOR HARDENER
Providing & applying coating of SUNFLOOR METALLIN
over the concrete slabs of pavements, parking lots,
swimming pool decks etc. Dilute 0.5kg SUNFLOOR
METALLIN in 3.5kgs of water. Use a broom or brush for
ensuring uniform absorbency of liquid in the entire area.
After 24 hrs. prepare a solution using 1 kg SUNFLOOR
METALLIN in 3kgs of water & apply the second coat.
Apply third coat after 24 hrs using 2 kgs of SUNFLOOR
METALLIN in 2kgs of water. Light foot traffic may be
allowed after 24 hours etc. all complete as per the
satisfaction of the EIC











Sq.m

OPTION 2: DRY SHAKE FLOOR HARDENER
Providing and sprinkling synthetic, non metallic, high
abrasion resistant floor hardener over the concrete slabs
of pavements, parking lots, swimming pool decks etc.
While the base concrete is about to set and the bleeding
water appears on the surface, sprinkle POLYABRES of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
over the bleeding water @3- 5 Kg per Sqm and finish
with trowel as per requirement. Allow to set for 24
hours and proceed with regular concrete curing
specification. Light foot traffic may be allowed after 24
hours etc. all complete as per the satisfaction of the EIC










Sq.m











24. HYGENIC COATING FOR WATER TANKS


Clean the existing cured internal surface of the water
tank so that it is free from loose particles, flakes and
ensure that the surface is dry & sound. Ensure to
provide necessary crack filling treatment if any on the
existing surface using epoxy mortar. Mix SUNEPOXY 378
of M/s. Sunanda Speciality Coatings Pvt. Ltd. or
equivalent (resin and hardener in the ratio of 1:0.5 by
weight) and apply by roller on the clean and dry surface.
Allow to air cure for 24 hours and apply similar two
coats to achieve final finish. Rate includes erection of
scaffolding cleaning, treatment to existing cracks,
application and cleaning at all levels etc. complete to the
satisfaction of the EIC













Sq.m



24
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

F. ANTI-CORROSIVE TREATMENT TO STEEL
25. RUST REMOVAL AND CONVERSION FOR STEEL





Remove loose rust from the reinforcement bars by
mechanical means like wire brushing, chipping,
hammering, etc. Using cotton waste swab apply
RUSTICIDE of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent. The rusted surface will turn from
reddish brown to blackish non-rusted colour. After 24
hours remove the free / loose rust particles by simple
dusting with brush, etc. complete to the satisfaction of
the EIC. Payment will be made on the quantity of
RUSTICIDE consumed.









Litres


26. RUST PASSIVATION OF STEEL

Prepare a lump free consistent slurry of 1 kg. of
POLYALK FIXOPRIME of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent with 1.25 kg. of fresh
grey cement. Do not add any water. Apply the above
slurry to the derusted steel surface by a paint brush.
Allow this coat to set for 24 hours & then apply a similar
second coat etc. complete to the satisfaction of the EIC.
Prepare as much slurry as can be applied within 30
minutes. Payment will be made on the quantity of
POLYALK FIXOPRIME used.









Litres











27. CORROSION PROTECTION TO STEEL WITH SACRIFICAL ANODE - SUNANODE

Providing and fixing in position zinc based sacrificial
anode- SUNANODE of M/s. Sunanda Speciality Coatings
Pvt. Ltd over the cleaned steel surface. Fixing to be done
using anode connectors or tack welding to steel surface.
The rate includes cleaning, applying, fixing in position,
welding at all heights etc. complete to the satisfaction of
the EIC.







Nos















25
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY


28. INTEGRAL CORROSION INHIBITING ADMIXTURE FOR RCC MEMBERS
Providing and laying R.C.C. of designed grade at all
heights and levels on well compacted/sound surfaces
using a mechanical mixer including dewatering,
shuttering, vibrating, curing and finishing as required.
Admix integral corrosion inhibitor POLYALK CP293 of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
@ 1% by weight of cement. The rate to include for
storage, handling, transportation of materials,
equipments etc using appropriate methods etc.
complete.








Cu.m


29. PU COATING FOR PROTECTION TO STRUCTURAL STEEL/ RAILINGS/ GRILLS
Clean the existing steel surface by scrubbing so as to
remove al the existing loose rust etc. Using cotton waste
swab apply RUSTICIDE of M/s. Sunanda Speciality
Coatings Pvt. Ltd. or equivalent. After 24 hours remove
the free / loose rust particles by simple dusting with
brush, etc. complete to the satisfaction of the EIC.
Providing and applying three coats of protective coating
of SUN PUGARD of M/s. Sunanda Speciality Coatings
Pvt. Ltd over the cleaned steel surface. Mix 4 parts of
Part-A to 1 part of Part-B using mechanical stirrer to
form uniform consistency. Apply the three coats by
brush or spray at 4-6 hours interval between each coat.
to the satisfaction of the EIC.












Sq. m































26
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY
G. ANCHORING OF DOWEL BARS
30. ANCHORING DOWEL BARS IN RCC MEMBERS USING EPOXY GROUTS

Drilling holes in the existing RCC surface beams,
columns, slabs for inserting dowel rods of stipulated
size. Mixing and placing SUNEPOXY 358 of M/s. Sunanda
Speciality Coatings Pvt. Ltd. or equivalent in the ratio ( 1
part Resin and 0.5 part Hardener) and pouring with
appropriate tools in the clean drilled hole. Ensure
surface is dry and free from moisture. Insert the dowel
rod in position and leave un-disturbed for next 24 hours.
If necessary give the packing to it. Further work to
proceed after 3 days of setting time. Rate to include
drilling, cleaning, placing epoxy, setting etc. all complete
as per the satisfaction of the EIC Payment will be made
on the quantity of SUNEPOXY 358 consumed














Liters











31 ROCK ANCHORING

Clean the drilled hole on the rock surface and remove
dust, loose particles, etc using electric blowers or
suction device. Apply bonding coat of POLYALK EP of
M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent
to the entire surface. Provide rod in place and pour high
strength POLYCRETE-A of M/s. Sunanda Speciality
Coatings Pvt. Ltd in the hole. POLYCRETE-A is prepared
by adding 12.5- 13% water by weight of POLYCRETE-A
and mixing it using mechanical stirrer to form flowable
consistency, curing etc complete to the satisfaction of
the EIC.











Nos

















27
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY

H. CURING COMPOUNDS
32. CURING COMPOUNDS

A

Clean the existing RCC and plaster surface by scrubbing
so as to remove all the existing, dust, dirt, grime, oil etc
and washing the surface clean with jet of water etc.
complete to the satisfaction of the EIC.


B

Providing and applying one pack curing compound
SUNPOLICURE of M/s. Sunanda Speciality Coatings Pvt.
Ltd. or equivalent on the entire surface using a curing
pump. Moisten the surface before the application and
saturate the substrate. Immediately while the surface is
damp spray SUNPOLICURE to form a uniform film over
the entire surface. The rate to include for application of
the same at all heights and levels etc. all complete as per
the satisfaction of the EIC










Sq.m

































28
Sunanda Speciality Coatings Pvt. Ltd. www.sunandaglobal.com
SUNANDA
S P E CI AL I T Y COAT I NGS P VT . L T D

AN I S O 9 0 0 1 : 2 0 0 8 COMP ANY


I.EPOXY FLOORING
33
EPOXY FLOORING

Clean the existing RCC and plaster surface by scrubbing
so as to remove all the existing, dust, dirt, grime, etc.
complete to the satisfaction of the EIC.



Providing and applying SUNEPOXY 378 of M/s.
Sunanda Speciality Coatings Pvt. Ltd. or equivalent and
apply by roller on the clean and dry RCC surface.


33a 1mm Self Leveling Epoxy flooring

Sq.m
33b 2mm Self Leveling Epoxy flooring

Sq.m
33c 3mm Epoxy Screed + Self Leveling Epoxy flooring

Sq.m