Vous êtes sur la page 1sur 28

Station and Intermediate Class

Surge Arresters
Product Overview
siemens.com/energy/arrester

Answers for energy.

High Voltage Reliable Protection

Siemens surge arresters have successfully


defied high winds, severe weather, harsh
environments and even earthquakes for
decades. Our surge arresters exhibit the
properties and provide the benefits that
ensure they will p
erform as intended
protecting equipment and systems from
lightning and switching overvoltages.

With decades of experience in the design and manufacturing of


high voltage power supply components, Siemens also specializes
in advanced Silicone Rubber (SR) insulated surge arresters providing the highest levels of mechanical strength, performance
and safety even in the most demanding environments, such as
in contaminated, industrially polluted, high seismic and vandal
prone critical installations.
The product family of our surge arresters offers the right solution
to any specific need. They have a proven fit for protecting transmission lines and transformers, as well as complete switchgear
from the hazards of high voltage start-up surges, line transients
and lightning. Siemens surge arresters have been successfully
tested to the latest ANSI/IEEE Standard C62.11.

As pioneers in the field of Silicone Rubber


(SR) insulation and one of the few suppliers
with comprehensive inhouse research and
development capabilities in this industry,
we can also provide surge arresters customized to very special requirements. The
cost-effectiveness of our products is underscored by uncompromising quality ensuring the long service life and reliability of
each application.
Available off-the-shelf, the 3EL standard
series of our SR surge arresters have been
designed to meet the requirements of
a wide range of common installation
environments. For more demanding applications, our high-end 3EQ series will maintain at least 75% of its nominal mechanical
strength in the event of a pressure relief,
and can thus also be used as a regular
support (station post) insulator.

Siemens Promise System Reliability

Silicone Rubber (SR) Insulation for Safety


Siemens offers two different types of arresters with SR housing:
The 3EL series for standard applications, and the advanced
3EQseries for the highest performance needs. Both are
designed u
sing the same glass collared MOV-blocks resulting
inoutstanding electrical performance.
SR has been used as an outdoor insulation material for over
25years, with excellent service experience even under severe
climatic and environmental conditions. Today, it is among the
most widely used materials for HV outdoor equipment.

Further key advantages of SR especially


compared to EPDM based alloy rubber
include:
High resistance to tracking erosion
Excellent resistance to flashover
Superior UV stability
Self-extinguishing flame retardancy
Adaptability to variable design and
ease of processing
For additional information call for our
publication on Silicone Rubber insulation.

Silicone is highly hydrophobic. While there are many polymeric


materials with similar initial hydrophobic properties, most of
them lose their hydrophobicity after a relatively short period such
as EPDM based alloy rubber. Only the true SR is capable of maintaining its hydrophobicity throughout its entire lifetime. This
ensures the long service life of our 3EL and 3EQ arresters.

One Goal 3 Designs


3EL Silicone Rubber (SR)
Surge Arresters with Cage Design

3EQ Silicone Rubber (SR)


Surge Arresters with Tube Design

3EP Porcelain Surge Arresters

The standard 3EL series is


based on a cage of p
restressed
fiber glass reinforced rods
for high mechanical strength.
The SR insulation is molded
directly onto the MOV-Blocks.
The design provides an
optimum price/performance
ratio for applications up to
345kV system voltage. The
3EL1 series as lower voltage
station class surge arrester
is an enhancement of our
3ELproduct line.

The fiber reinforced plastic


(FRP) tube material has been
chosen to provide the highest
possible mechanical strength.
Due to its excellent processi
bility, the SR insulation is
molded directly onto the
FRP tube.
The 3EQ tube design is
considered the best choice
for applications up to
1200kV system voltage,
particularly in locations
or installations with demanding environmental or
extremely high mechanical/
seismic requirements.

The high-quality porcelain


housing of the 3EP as well
as the special grade sulfur
cement bonding of housing
and flanges ensure
outstanding mechanical
strength, for applications
up to 800 kV.

3EL

Total encapsulation of all components


to avoid partial discharges and moisture
ingress
High mechanical performance for
standard applications
Silicone Rubber shielding provides
low-pressure release of the arc in
the event of a short circuit
Significant weight savings vs.
comparable porcelain arresters,
facilitating transport and installation
of the arresters
Suitable for use as substation and/or
line surge arresters

3EQ

FRP tube design for outstanding


mechanical stability (much stronger
than porcelain), combined with an
excellent sealing system for long-life
protection against ingress of moisture
and partial discharges
Highest level of safety in the event
of short circuits, no ejection of any
internal components
Retention of at least 75% of initial
mechanical strength even after short
circuit, permits the use of the arrester
as a support insulator
Weight savings vs. comparable
porcelain arresters
Ideal for applications in areas exposed
to high seismic activity, heavy wind loads
and any other demanding mechanical
requirements
Available as single-unit arrester rated
up to 300 kV or two-unit arresters for
up to 550 kV, minimizing the required
number of units
High reliability over a wide range of
temperatures and extreme temperature
changes from 67F to +122F
(55C to +50C)

3EP

Reliable technology with a proven


history
Optimized glass collared MOV-block
design
Pressure relief system for very fast
venting, providing the highest possible
means of safety in areas requiring
special protection
Very high cantilever strength
Highly reliable sealing system and state
of the art seal test set-up make Siemens
arresters completely reliable

Product Range
We offer multiple models for each family of arresters.
They differ mainly in diameter and length of the
housings and size of the M
OV-blocks to fulfill different
customer requirements.

3EL5

3EL1

3EL2

3EQ1

3EQ4

Silicone Rubber

3EP5

3EP4

3EP6

Porcelain

Reliable power transmission

... even in extreme climates ...

... and high seismic impact locations

Application: Fixed series capacitor


protected by arrester banks, consisting of
multi-column 3EP3 arresters connected
in parallel
Key benefits: Improved power trans
mission quality.

Application: Three advanced series


3-phase static compensators protected
by arrester banks, consisting of multi-
column arresters connected in parallel
Key benefits: Enhanced power trans
mission quality at high reliability under
extreme climatic conditions. All of these
arresters are capable of withstanding
temperature extremes of 67F to +122F
(55C to +50C).

Application: Innovative installation of


3EQ3 surge arresters for protection of
hanging thyristor valves in a 500 kV
HVDC long-distance power transmission
system
Key benefits: Superior resistance to seismic shock for optimum reliability of HVDC
transmission. These arresters are capable
of withstanding seismic forces up to 1g.

Customer: ENTERGY Services Inc.


Project name: Jacinto
Location: Near Cleveland, Texas

Customer: Hydro-Qubec
Project name: Montagnais FSC
Location: Montagnais, Quebec, Canada

Customer: Los Angeles Department


of Water and Power
Project name: Sylmar East,
Valve Reconstruction
Location: Sylmar, California
5

Rating and Specifications


Intermediate Class Silicone Rubber Housed Arrester, Type 3EL5

Electrical Characteristics
Duty
cycle
voltage

MCOV

TOV
Capability
w/o duty

Protective Level
Maximum discharge voltage

FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
250 A
[kV cr]

45/90 s
500 A
[kV cr]

[kV]

[kV]

for 0.1s
[kV]

2.55

3.6

8.1

6.8

7.1

7.4

8.0

9.1

10.6

6.0

6.1

3EL5 003-0PB11-4YH5

5.1

7.1

16.2

13.5

14.2

14.8

15.9

18.3

21.1

11.9

12.2

3EL5 006-0PB11-4YH5

7.7

10.7

24.3

20.3

21.2

22.2

23.9

27.4

31.7

17.9

18.4

3EL5 009-0PB11-4YH5

10

8.4

11.7

27.0

22.5

23.6

24.6

26.5

30.5

35.2

19.9

20.4

3EL5 010-0PB11-4YH5

12

10.2

14.2

32.4

27.0

28.3

29.6

31.8

36.6

42.3

23.9

24.5

3EL5 012-0PC11-4YH5

15

12.7

17.7

40.5

33.8

35.4

37.0

39.8

45.7

52.9

29.8

30.6

3EL5 015-0PC11-4YH5

18

15.3

21.3

48.7

40.5

42.5

44.4

47.7

54.9

63.4

35.8

36.7

3EL5 018-0PD11-4YH5

21

17.0

23.7

56.8

47.3

49.5

51.8

55.7

64.0

74.0

41.7

42.9

3EL5 021-0PD11-4YH5

24

19.5

27.2

64.9

54.1

56.6

59.1

63.6

73.1

84.6

47.7

49.0

3EL5 024-0PE11-4YH5

27

22.0

30.7

73.0

60.8

63.7

66.5

71.6

82.3

95

53.7

55.1

3EL5 027-0PE11-4YH5

30

24.4

34.0

81.1

67.6

70.8

73.9

79.5

91.4

106

59.6

61.2

3EL5 030-0PF11-4YH5

36

29.0

40.5

97.3

81.1

84.9

88.7

95.4

110

127

71.6

73.5

3EL5 036-0PH11-4YH5

39

31.5

43.9

105

87.8

92.0

96.1

103

119

137

77.5

79.6

3EL5 039-0PH11-4YH5

45

36.5

50.9

122

101

106

111

119

137

159

89.4

91.8

3EL5 045-0PH11-4YH5

48

39.0

54.4

130

108

113

118

127

146

169

95.4

97.9

3EL5 048-0PH11-4YH5

54

42

58.6

146

122

127

133

143

165

190

107

110

3EL5 054-0PJ11-4YH5

60

48

67.0

162

135

142

148

159

183

211

119

122

3EL5 060-0PK11-4YH5

72

57

79.5

195

162

170

177

191

219

254

143

147

3EL5 072-0PH12-4YH5

90

70

97.7

243

203

212

222

239

274

317

179

184

3EL5 090-0PH12-4YH5

96

76

106

259

216

226

237

254

293

338

191

196

3EL5 096-0PH12-4YH5

Table 1: Intermediate Class Silicone Rubber Housed Arrester, Type 3EL5


(The table shows only standard arresters, other special types are available on request.)

8/20 s
20 kA
[kV cr]

Arrester order number

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Energy
(thermal)

Creepage
distance

Height
H

Grading
ring
diameter

Cantilever
strength*
(MDCL)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

20

4.5

15

3098

20

4.5

15

3098

20

4.5

15

3098

20

4.5

15

3098

20

4.5

19

3098

20

4.5

19

3098

20

4.5

24

3098

20

4.5

24

3098

20

4.5

31

11

3098

20

4.5

31

11

3098

20

4.5

35

12

3098

10

20

4.5

48

16

3098

11

20

4.5

48

16

3098

12

20

4.5

48

16

3098

13

20

4.5

48

16

3098

13

20

4.5

56

19

3098

14

20

4.5

63

20

3098

15

20

4.5

97

33

3098

20

20

4.5

97

33

3098

22

20

4.5

97

33

3098

22

Mechanical Characteristics
Short
circuit
current
0.2 s

* MDCL-static (Maximum design cantilever load-static) = Designed to


continuously carry working load, and this applies to polymer housed
arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever
Strength (Design Load), and this applies to porcelain housed arresters

Fig. 1: Height of a surge arrester


(applies to all surge arresters of this catalog)

Rating and Specifications


Station Class Silicone Rubber Housed Surge Arrester, Type 3EL1

Electrical Characteristics
Duty
cycle
voltage

MCOV

TOV
Capability
w/o duty

Protective Level
Maximum discharge voltage

FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
250 A
[kV cr]

45/90 s
500 A
[kV cr]

[kV]

[kV]

for 0.1 s
[kV]

2.55

4.0

8.6

6.6

6.9

7.3

7.8

8.7

10.0

5.9

6.0

3EL1 003-1PC21-4YH5

5.10

8.0

17.2

13.3

13.9

14.5

15.6

17.5

20.0

11.7

12.0

3EL1 006-1PC21-4YH5

7.65

11.9

25.7

19.9

20.8

21.8

23.4

26.2

30.0

17.6

18.0

3EL1 009-1PC21-4YH5

10

8.40

13.1

28.6

22.1

23.1

24.2

26.0

29.1

33.3

19.5

20.0

3EL1 010-1PC21-4YH5

12

10.2

15.9

34.3

26.5

27.8

29.0

31.2

34.9

39.9

23.4

24.0

3EL1 012-1PC21-4YH5

15

12.7

19.8

42.9

33.2

34.7

36.3

39.0

43.7

49.9

29.3

30.0

3EL1 015-1PC21-4YH5

18

15.3

23.9

51.5

39.8

41.7

43.5

46.8

52.4

59.9

35.1

36.0

3EL1 018-1PC21-4YH5

21

17.0

26.5

60.1

46.4

48.6

50.8

54.6

61.2

69.9

41.0

42.0

3EL1 021-1PC21-4YH5

24

19.5

30.4

68.6

53.0

55.5

58.0

62.4

69.9

79.9

46.8

48.0

3EL1 024-1PC21-4YH5

27

22.0

34.3

77.2

59.7

62.5

65.3

70.2

78.6

89.9

52.7

54.1

3EL1 027-1PE21-4YH5

30

24.4

38.1

85.8

66.3

69.4

72.5

78.0

87.4

99.8

58.5

60.1

3EL1 030-1PE21-4YH5

36

29.0

45.2

103

79.6

83.3

87.0

93.6

105

120

70.2

72.1

3EL1 036-1PE21-4YH5

39

31.5

49.1

112

86.2

90.2

94.3

101

114

130

76

78

3EL1 039-1PH21-4YH5

45

36.5

56.9

129

99.5

104

109

117

131

150

87.8

90.1

3EL1 045-1PH21-4YH5

48

39.0

60.8

137

106

111

116

125

140

160

93.6

96.1

3EL1 048-1PH21-4YH5

54

42.0

65.5

154

119

125

131

140

157

180

105

108

3EL1 054-1PH21-4YH5

60

48.0

74.9

172

133

139

145

156

175

200

117

120

3EL1 060-1PH21-4YH5

72

57.0

88.9

206

159

167

174

187

210

240

140

144

3EL1 060-1PK21-4YH5

72

57.0

88.9

206

159

167

174

187

210

240

140

144

3EL1 072-1PK21-4YH5

90

70.0

109

257

199

208

218

234

262

300

176

180

3EL1 090-1PK21-4YH5

96

76.0

119

275

212

222

232

250

280

319

187

192

3EL1 096-1PK21-4YH5

108

84.0

131

309

239

250

261

281

314

359

211

216

3EL1 108-1PN22-4YH5

120

98.0

153

343

265

278

290

312

349

399

234

240

3EL1 120-1PH22-4YH5

132

106

165

378

292

305

319

343

384

439

257

264

3EL1 132-1PH22-4YH5

144

115

179

412

318

333

348

374

419

479

281

288

3EL1 144-1PP22-4YH5

168

131

204

480

371

389

406

437

489

559

328

336

3EL1 168-1PQ22-4YH5

172

140

218

492

380

398

416

447

501

572

335

344

3EL1 172-1PQ22-4YH5

180

144

225

515

398

417

435

468

524

599

351

360

3EL1 180-1PK22-4YH5

192

152

237

549

424

444

464

499

559

639

374

384

3EL1 192-1PK22-4YH5

Table 2: Station Class Silicone Rubber Housed Surge Arrester, Type 3EL1
(The table shows only standard arresters, other special types are available on request.)

8/20 s
20 kA
[kV cr]

Arrester order number

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Short
circuit
current
0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading
ring
diameter

Cantilever
strength*
(MDCL)

Weight

[kA]

[kJ/kV
mcov}

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

65

6.3

35

12

7435

13

65

6.3

35

12

7435

13

65

6.3

35

12

7435

14

65

6.3

35

12

7435

14

65

6.3

35

12

7435

14

65

6.3

35

12

7435

15

65

6.3

35

12

7435

15

65

6.3

35

12

7435

15

65

6.3

35

12

7435

15

65

6.3

55

18

7435

19

65

6.3

55

18

7435

19

65

6.3

55

18

7435

19

65

6.3

81

24

7435

23

65

6.3

81

24

7435

23

65

6.3

81

24

7435

23

65

6.3

81

24

7435

24

65

6.3

81

24

7435

25

65

6.3

121

35

7435

29

65

6.3

121

35

7435

30

65

6.3

121

35

7435

33

65

6.3

121

35

7435

34

65

6.3

136

42

7435

41

65

6.3

161

49

7435

45

65

6.3

161

49

7435

47

65

6.3

176

53

7435

50

65

6.3

202

60

7435

56

65

6.3

242

71

7435

60

65

6.3

242

71

7435

61

65

6.3

242

71

7435

63

* MDCL-static (Maximum design cantilever load-static) = Designed to


continuously carry working load, and this applies to polymer housed
arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever
Strength (Design Load), and this applies to porcelain housed arresters

Rating and Specifications


Station Class Silicone Rubber Housed Surge Arrester, Type 3EL2

Electrical Characteristics
Duty
cycle
voltage

MCOV

TOV
Capability
w/o duty

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
20 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
250 A
[kV cr]

[kV]

[kV]

2.55

4.0

7.8

6.2

6.5

6.8

7.2

8.0

9.1

5.6

5.10

8.0

15.7

12.4

13.0

13.5

14.4

16.0

18.1

11.2
16.8

7.65

11.9

23.5

18.6

19.4

20.3

21.6

24.0

27.2

10

8.4

13.1

26.2

20.6

21.6

22.6

24.0

26.6

30.2

18.7

12

10.2

15.9

31.4

24.8

25.9

27.1

28.8

32.0

36.3

22.5

15

12.7

19.8

39.2

31.0

32.4

33.8

36.0

40.0

45.4

28.1

18

15.3

23.9

47.1

37.2

38.9

40.6

43.2

48.0

54.4

33.7

21

17.0

26.5

54.9

43.3

45.4

47.4

50.4

55.9

63.5

39.3

24

19.5

30.4

62.8

49.5

51.8

54.1

57.6

63.9

72.6

44.9

27

22.0

34.3

70.6

55.7

58.3

60.9

64.8

71.9

81.6

50.5

30

24.4

38.1

78.5

61.9

64.8

67.7

72.0

79.9

90.7

56.2

36

29.0

45.2

94.2

74.3

77.8

81.2

86.4

95.9

109

67.4

39

31.5

49.1

102

80.5

84.2

88.0

93.6

104

118

73.0

45

36.5

56.9

118

92.9

97.2

102

108

120

136

84.2

48

39.0

60.8

126

99.1

104

108

115

128

145

89.9

54

42.0

65.5

141

111

117

122

130

144

163

101

60

48.0

74.9

157

124

130

135

144

160

181

112

72

57.0

88.9

188

149

156

162

173

192

218

135

90

70.0

109

235

186

194

203

216

240

272

168

96

76.0

119

251

198

207

217

230

256

290

180

108

84.0

131

283

223

233

244

259

288

327

202

111

88.0

137

290

229

240

250

266

296

336

208

120

98.0

153

314

248

259

271

288

320

363

225

132

106

165

345

272

285

298

317

352

399

247

144

115

179

377

297

311

325

346

384

435

270

168

131

204

439

347

363

379

403

448

508

314

172

140

218

450

355

372

388

413

458

520

322

180

144

225

471

372

389

406

432

480

544

337

192

152

237

502

396

415

433

461

511

581

359

228

180

281

596

471

492

514

547

607

689

427

240

190

296

628

495

518

541

576

639

726

449

258

209

326

675

533

557

582

619

687

780

483

264

212

331

691

545

570

596

634

703

798

494

276

220

343

722

570

596

623

662

735

835

517

264

212

331

698

528

546

571

607

668

729

480

276

220

343

730

552

571

597

635

698

762

501

288

230

359

762

576

596

623

662

729

795

523

294

235

367

778

588

609

636

676

744

811

534

312

245

382

825

624

646

675

718

789

861

567

Table 3: Station Class Silicone Rubber Housed Arrester, Type 3EL2


(The table shows only standard arresters, other special types are available on request.)

10

8/20 s
5 kA
[kV cr]

for 0.1 s
[kV]

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Arrester order number
45/90 s
500 A
[kV cr]

Short circuit
current 0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(MDCL)

Weight

[kA]

[kJ/kV
mcov]

[lbs]

[inch]

[inch]

[inch]

[inch-lbf]

5.8

3EL2 003-2PC31-4XH5

65

10.0

58

19

24782

32

11.5

3EL2 006-2PC31-4XH5

65

10.0

58

19

24782

32

17.3

3EL2 009-2PC31-4XH5

65

10.0

58

19

24782

32

19.2

3EL2 010-2PC31-4XH5

65

10.0

58

19

24782

32

23.0

3EL2 012-2PC31-4XH5

65

10.0

58

19

24782

33

28.8

3EL2 015-2PC31-4XH5

65

10.0

58

19

24782

33

34.6

3EL2 018-2PC31-4XH5

65

10.0

58

19

24782

35

40.3

3EL2 021-2PC31-4XH5

65

10.0

58

19

24782

35

46.1

3EL2 024-2PC31-4XH5

65

10.0

58

19

24782

36

51.8

3EL2 027-2PC31-4XH5

65

10.0

58

19

24782

36

57.6

3EL2 030-2PC31-4XH5

65

10.0

58

19

24782

36

69.1

3EL2 036-2PC31-4XH5

65

10.0

58

19

24782

37

74.9

3EL2 039-2PC31-4XH5

65

10.0

58

19

24782

38

86.4

3EL2 045-2PF31-4XH5

65

10.0

92

28

24782

45

92.2

3EL2 048-2PF31-4XH5

65

10.0

92

28

24782

45

104

3EL2 054-2PF31-4XH5

65

10.0

92

28

24782

47

115

3EL2 060-2PF31-4XH5

65

10.0

92

28

24782

48

138

3EL2 072-2PF31-4XH5

65

10.0

92

28

24782

49

173

3EL2 090-2PJ31-4XH5

65

10.0

150

42

24782

62

184

3EL2 096-2PJ31-4XH5

65

10.0

150

42

24782

63

207

3EL2 108-2PJ31-4XH5

65

10.0

150

42

24782

66

213

3EL2 111-2PJ31-4XH5

65

10.0

150

42

24782

66

230

3EL2 120-2PJ31-4XH5

65

10.0

150

42

24782

67

253

3EL2 132-2PM31-4XH5

65

10.0

177

49

24782

74

276

3EL2 144-2PM31-4XH5

65

10.0

177

49

24782

76

323

3EL2 168-2PQ32-4XH5

65

10.0

243

70

24782

104

330

3EL2 172-2PQ32-4XH5

65

10.0

243

70

24782

104

346

3EL2 180-2PQ32-4XH5

65

10.0

243

70

24782

105

369

3EL2 192-2PQ32-4XH5

65

10.0

243

70

24782

108

438

3EL2 228-2PJ32-4XH5

65

10.0

301

84

24782

123

461

3EL2 240-2PJ32-4XH5

65

10.0

301

84

24782

126

495

3EL2 258-2PW32-4XH5

65

10.0

327

91

24

24782

134

507

3EL2 264-2PM32-4XH5

65

10.0

354

98

31

24782

140

530

3EL2 276-2PM32-4XH5

65

10.0

354

98

31

24782

142

492

3EL2 264-6PW42-4XH5

65

12.5

327

91

24

24782

140

514

3EL2 276-6PM42-4XH5

65

12.5

354

98

31

24782

146

537

3EL2 288-6PM42-4XH5

65

12.5

354

98

31

24782

149

548

3EL2 294-6PX43-4XH5

65

12.5

393

111

31

24782

167

581

3EL2 312-6PX43-4XH5

65

12.5

393

111

31

24782

173

* MDCL-static (Maximum design cantilever load-static) = Designed to continuously carry working load, and this applies to polymer housed arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever Strength (Design Load), and this applies to porcelain housed arresters

11

Rating and Specifications


Station Class Silicone Rubber Arrester, Type 3EQ1

Electrical Characteristics
Duty
cycle
voltage

[kV]

MCOV

[kV]

TOV
Capability
w/o duty
for 0.1 s
[kV]

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
15 kA
[kV cr]

8/20 s
20 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
500 A
[kV cr]

45/90 s
1 kA
[kV cr]

10

8.4

13.1

28.6

22.1

23.1

24.2

26.0

27.8

29.1

33.3

20.0

20.8

27

22.0

34.3

77.2

59.7

62.5

65.3

70.2

75.1

78.6

89.9

54.1

56.2

30

24.4

38.1

85.8

66.3

69.4

72.5

78.0

83.5

87.4

99.8

60.1

62.4

30

24.4

38.1

78

61.9

64.8

68

72

76

80

91

57.6

59.0

36

29.0

45.2

103

79.6

83.3

87.0

93.6

100

105

120

72.1

74.9

39

31.5

49.1

112

86.2

90.2

94.3

101

108

114

130

78.1

81.1

45

36.5

56.9

118

92.9

97.2

102

108

114

120

136

86.4

88.6

48

39.0

60.8

126

99.1

104

108

115

122

128

145

92.2

94.5

54

42.0

65.5

141

111

117

122

130

137

144

163

104

106

60

48.0

74.9

157

124

130

135

144

153

160

181

115

118

72

57.0

88.9

188

149

156

162

173

183

192

218

138

142

90

70.0

109

235

186

194

203

216

229

240

272

173

177

96

76.0

119

251

198

207

217

230

244

256

290

184

189

108

84.0

131

283

223

233

244

259

275

288

327

207

213

111

88.0

137

290

229

240

250

266

282

296

336

213

218

120

98.0

153

314

248

259

271

288

305

320

363

230

236

132

106

165

345

272

285

298

317

336

352

399

253

260

144

115

179

377

297

311

325

346

366

384

435

276

283

168

131

204

439

347

363

379

403

427

448

508

323

331

172

140

218

450

355

372

388

413

438

458

520

330

338

180

144

225

471

372

389

406

432

458

480

544

346

354

192

152

237

502

396

415

433

461

488

511

581

369

378

228

180

281

596

471

492

514

547

580

607

689

438

449

240

190

296

628

495

518

541

576

611

639

726

461

472

258

209

326

675

533

557

582

619

656

687

780

495

508

276

220

343

722

570

596

623

662

702

735

835

530

543

Table 4: Station Class Silicone Rubber Arrester, Type 3EQ1


(The table shows only standard arresters, other special types are available on request.)

12

8/20 s
10 kA
[kV cr]

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Arrester order number
45/90 s
2 kA
[kV cr]

Short circuit
current 0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(MDCL)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

21.8

3EQ1 010-1PB21-4XH5

50

6.3

82

35

37173

51

59.0

3EQ1 027-1PB21-4XH5

50

6.3

82

35

37173

53

65.5

3EQ1 030-1PB21-4XH5

50

6.3

82

35

37173

53

61.9

3EQ1 030-2PB31-4XH5

50

10

82

35

37173

54

78.6

3EQ1 036-1PB21-4XH5

50

6.3

82

35

37173

54

85.2

3EQ1 039-1PB21-4XH5

50

6.3

82

35

37173

54

92.9

3EQ1 045-2PB31-4XH5

50

10

82

35

37173

58

99.1

3EQ1 048-2PB31-4XH5

50

10

82

35

37173

58

111

3EQ1 054-2PB31-4XH5

50

10

82

35

37173

59

124

3EQ1 060-2PB31-4XH5

50

10

82

35

37173

60

149

3EQ1 072-2PB31-4XH5

50

10

82

35

37173

61

186

3EQ1 090-2PE31-4XH5

40

10

104

41

37173

70

198

3EQ1 096-2PE31-4XH5

40

10

104

41

37173

71

223

3EQ1 108-2PJ31-4XH5

40

10

133

49

37173

78

229

3EQ1 111-2PJ31-4XH5

40

10

133

49

37173

78

248

3EQ1 120-2PJ31-4XH5

40

10

133

49

37173

79

272

3EQ1 132-2PJ31-4XH5

40

10

133

49

37173

82

297

3EQ1 144-2PP31-4XH5

40

10

170

58

37173

87

347

3EQ1 168-2PP31-4XH5

40

10

170

58

37173

94

355

3EQ1 172-2PS31-4XH5

40

10

193

64

37173

98

372

3EQ1 180-2PS31-4XH5

40

10

193

64

37173

99

396

3EQ1 192-2PS31-4XH5

40

10

193

64

37173

102

471

3EQ1 228-2PJ32-4XH5

40

10

267

97

31

37173

152

495

3EQ1 240-2PJ32-4XH5

40

10

267

97

31

37173

155

533

3EQ1 258-2PP32-4XH5

40

10

341

117

31

37173

168

570

3EQ1 276-2PP32-4XH5

40

10

341

117

31

37173

171

* MDCL-static (Maximum design cantilever load-static) = Designed to continuously carry working load, and this applies to polymer housed arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever Strength (Design Load), and this applies to porcelain housed arresters

13

Rating and Specifications


Station Class Silicone Rubber Arrester, Type 3EQ4

Silicone Rubber type 3EQ4 (500 kV)

Electrical Characteristics
Duty
cycle
voltage

[kV]

MCOV

[kV]

TOV
Capability
w/o duty
for 0.1 s
[kV]

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
15 kA
[kV cr]

8/20 s
20 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
500 A
[kV cr]

45/90 s
1 kA
[kV cr]

108

84

131

283

223

233

244

259

275

288

327

207

213

180

144

225

471

372

389

406

432

458

480

544

346

354

180

144

225

486

372

385

400

423

444

461

503

351

362

258

209

326

675

533

557

582

619

656

687

780

495

508

258

209

326

697

534

552

573

606

637

661

721

503

518

264

212

331

691

545

570

596

634

672

703

798

507

520

264

212

331

713

546

565

586

620

651

676

738

515

530

276

220

343

722

570

596

623

662

702

735

835

530

543

276

220

343

746

571

590

613

649

681

707

772

538

555

288

230

359

753

594

622

650

691

733

767

871

553

567

288

230

359

778

596

616

640

677

711

738

805

562

579

294

235

367

769

607

635

663

706

748

783

889

564

579

294

235

367

795

608

629

653

691

725

753

822

573

591

312

245

382

843

645

667

693

733

770

799

873

609

627

396

318

496

1070

819

847

879

931

977

1014

1107

772

796

396

318

487

1025

784

811

842

891

936

971

1060

740

762

420

335

523

1135

869

898

933

987

1036

1076

1175

819

844

420

335

513

1087

832

860

893

945

992

1030

1125

784

808

444

353

551

1200

918

949

986

1043

1096

1137

1242

866

892

444

353

540

1149

879

909

944

999

1049

1089

1189

829

854

468

372

569

1211

927

958

995

1053

1106

1148

1253

874

900

588

470

719

1521

1164

1204

1250

1323

1389

1442

1574

1098

1131

Table 5: Station Class Silicone Rubber Arrester, Type 3EQ4


(The table shows only standard arresters, other special types are available on request.)

14

8/20 s
10 kA
[kV cr]

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Arrester order number
45/90 s
2 kA
[kV cr]

Short circuit
current 0.2 s**

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(MDCL)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

223

3EQ4 108-2PK31-4XH5

65

10

156

57

130106

225

372

3EQ4 180-2PN31-4XH5

65

10

200

69

130106

243

372

3EQ4 180-3PR41-4XH5

65

12.5

244

81

130106

292

533

3EQ4 258-2PV31-4XH5

65

10

304

97

130106

287

534

3EQ4 258-3PV41-4XH5

65

12.5

304

97

130106

326

545

3EQ4 264-2PV31-4XH5

65

10

304

97

130106

288

546

3EQ4 264-3PV41-4XH5

65

12.5

304

97

130106

328

570

3EQ4 276-2PV31-4XH5

65

10

304

97

130106

290

571

3EQ4 276-3PN42-4XH5

65

12.5

400

139

39

130106

445

594

3EQ4 288-2PN32-4XH5

65

10

400

139

39

130106

404

596

3EQ4 288-3PN42-4XH5

65

12.5

400

139

39

130106

449

607

3EQ4 294-2PN32-4XH5

65

10

400

139

39

130106

405

608

3EQ4 294-3PN42-4XH5

65

12.5

400

139

39

130106

451

645

3EQ4 312-3PN42-4XH5

65

12.5

400

139

39

130106

457

819

3EQ4 396-3PS42-4XH5

65

12.5

519

170

47

130106

509

784

3EQ4 396-4PR52-4XH5

65

17.5

489

162

47

130106

535

869

3EQ4 420-3PV42-4XH5

65

12.5

607

194

59

130106

533

832

3EQ4 420-4PV52-4XH5

65

17.5

607

194

59

130106

564

918

3EQ4 444-3PV42-4XH5

65

12.5

607

194

59

130106

541

879

3EQ4 444-4PV52-4XH5

65

17.5

607

194

59

130106

573

927

3EQ4 468-4PV52-4XH5

65

17.5

607

194

59

130106

584

3EQ4 588-4PS57-4XH9 R4C

65

17.5

778

255

83

235430

746

1164

* MDCL-static (Maximum design cantilever load-static) = Designed to continuously carry working load, and this applies to polymer housed arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever Strength (Design Load), and this applies to porcelain housed arresters
** 80 kA short circuit current available on request

15

Rating and Specifications


Station Class Porcelain Arrester, Type 3EP5 and 3EP4

Electrical Characteristics
Duty
cycle
voltage

[kV]

MCOV

[kV]

TOV
Capability
w/o duty
for 0.1 s
[kV]

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
40 kA
[kV cr]

8/20 s
20 kA
[kV cr]

45/90 s
500 A
[kV cr]

45/90 s
1 kA
[kV cr]

45/90 s
2 kA
[kV cr]

10

8.4

13.1

28.6

22.1

23.1

24.2

26.0

29.1

33.3

20.0

20.8

21.8

27

22.0

34.3

77.2

59.7

62.5

65.3

70.2

78.6

89.9

54.1

56.2

59.0

30

24.4

38.1

85.8

66.3

69.4

72.5

78.0

87.4

99.8

60.1

62.4

65.5

36

29.0

45.2

103

79.6

83.3

87.0

93.6

105

120

72.1

74.9

78.6

39

31.5

49.1

112

86.2

90.2

94.3

101

114

130

78.1

81.1

85.2

45

36.5

56.9

118

92.9

97.2

102

108

120

136

86.4

88.6

92.9

48

39.0

60.8

126

99.1

104

108

115

128

145

92.2

94.5

99.1

54

42.0

65.5

141

111

117

122

130

144

163

104

106

111

60

48.0

74.9

157

124

130

135

144

160

181

115

118

124

72

57.0

88.9

188

149

156

162

173

192

218

138

142

149

MCOV

TOV
Capability
w/o duty

Electrical Characteristics
Duty
cycle
voltage

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
20 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
500 A
[kV cr]

45/90 s
1 kA
[kV cr]

45/90 s
2 kA
[kV cr]

[kV]

[kV]

for 0.1 s
[kV]

90

70.0

109

235

186

194

203

216

240

272

173

177

186

96

76.0

119

251

198

207

217

230

256

290

184

189

198

108

84.0

131

283

223

233

244

259

288

327

207

213

223

111

88.0

137

290

229

240

250

266

296

336

213

218

229

120

98.0

153

314

248

259

271

288

320

363

230

236

248

132

106

165

345

272

285

298

317

352

399

253

260

272

144

115

179

377

297

311

325

346

384

435

276

283

297

168

131

204

439

347

363

379

403

448

508

323

331

347

172

140

218

450

355

372

388

413

458

520

330

338

355

180

144

225

471

372

389

406

432

480

544

346

354

372

192

152

237

502

396

415

433

461

511

581

369

378

396

228

180

281

596

471

492

514

547

607

689

438

449

471

240

190

296

628

495

518

541

576

639

726

461

472

495

258

209

326

675

533

557

582

619

687

780

495

508

533

264

212

331

691

545

570

596

634

703

798

507

520

545

Table 6: Station Class Porcelain Arrester, Type 3EP5 and 3EP4


(The table shows only standard arresters, other special types are available on request.)

16

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Short circuit
current 0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(UMS-static)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

3EP5 010-1PC21-3XH5

40

6.3

26

14

21242

46

3EP5 027-1PE21-3XH5

40

6.3

50

22

21242

63

3EP5 030-1PE21-3XH5

40

6.3

50

22

21242

63

3EP5 036-1PE21-3XH5

40

6.3

50

22

21242

64

3EP5 039-1PE21-3XH5

40

6.3

50

22

21242

64

3EP5 045-2PE31-3XH5

40

10

50

22

21242

68

3EP5 048-2PE31-3XH5

40

10

50

22

21242

68

3EP5 054-2PH31-3XH5

40

10

74

30

21242

83

3EP5 060-2PH31-3XH5

40

10

74

30

21242

84

3EP5 072-2PH31-3XH5

40

10

74

30

21242

86

Arrester order number

Short circuit
current 0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(UMS-static)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

3EP4 090-2PD31-3XH5

65

10

98

41

47794

108

3EP4 096-2PD31-3XH5

65

10

98

41

47794

109

3EP4 108-2PE31-3XH5

65

10

134

52

47794

138

3EP4 111-2PE31-3XH5

65

10

134

52

47794

138

3EP4 120-2PE31-3XH5

65

10

134

52

47794

139

3EP4 132-2PE31-3XH5

65

10

134

52

47794

142

3EP4 144-2PF31-3XH5

65

10

151

57

47794

155

3EP4 168-2PD32-3XH5

65

10

196

83

47794

227

3EP4 172-2PD32-3XH5

65

10

196

83

47794

227

3EP4 180-2PD32-3XH5

65

10

196

83

47794

228

3EP4 192-2PD32-3XH5

65

10

196

83

47794

231

3EP4 228-2PE32-3XH5

65

10

268

104

31

47794

291

3EP4 240-2PF32-3XH5

65

10

302

115

31

47794

320

3EP4 258-2PF32-3XH5

65

10

302

115

31

47794

324

3EP4 264-2PF32-3XH5

65

10

302

115

31

47794

325

Arrester order number

Mechanical Characteristics

* MDCL-static (Maximum design cantilever load-static) = Designed to continuously carry working load, and this applies to polymer housed arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever Strength (Design Load), and this applies to porcelain housed arresters

17

Rating and Specifications


Station Class Porcelain Arrester, Type 3EP6

Electrical Characteristics
Duty
cycle
voltage

MCOV

TOV
Capability
w/o duty

Protective Level
Maximum discharge voltage
FOW
[kV cr]

8/20 s
1.5 kA
[kV cr]

8/20 s
3 kA
[kV cr]

8/20 s
5 kA
[kV cr]

8/20 s
10 kA
[kV cr]

8/20 s
20 kA
[kV cr]

8/20 s
40 kA
[kV cr]

45/90 s
500 A
[kV cr]

45/90 s
1 kA
[kV cr]

45/90 s
2 kA
[kV cr]

[kV]

[kV]

for 0.1 s
[kV]

108

84.0

131

283

223

233

244

259

288

327

207

213

223

111

88.0

137

290

229

240

250

266

296

336

213

218

229

120

98.0

153

314

248

259

271

288

320

363

230

236

248

132

106.0

165

345

272

285

298

317

352

399

253

260

272

144

115.0

179

377

297

311

325

346

384

435

276

283

297

168

131.0

204

439

347

363

379

403

448

508

323

331

347

172

140.0

218

450

355

372

388

413

458

520

330

338

355

180

144.0

225

471

372

389

406

432

480

544

346

354

372

192

152.0

237

502

396

415

433

461

511

581

369

378

396

228

180.0

281

596

471

492

514

547

607

689

438

449

471

240

190.0

296

628

495

518

541

576

639

726

461

472

495

258

209.0

326

675

533

557

582

619

687

780

495

508

533

258

209

326

697

534

552

573

606

661

721

503

518

534

264

212.0

331

691

545

570

596

634

703

798

507

520

545

264

212

331

713

546

565

586

620

676

738

515

530

546

276

220.0

343

722

570

596

623

662

735

835

530

543

570

276

220

343

746

571

590

613

649

707

772

538

555

571

288

230.0

359

753

594

622

650

691

767

871

553

567

594

288

230

359

778

596

616

640

677

738

805

562

579

596

294

235.0

367

769

607

635

663

706

783

889

564

579

607

294

235

367

795

608

629

653

691

753

822

573

591

608

312

245

382

843

645

667

693

733

799

873

609

627

645

396

318

496

1070

819

847

879

931

1014

1107

772

796

819

396

318

487

1025

784

811

842

891

971

1060

740

762

784

420

335

523

1135

869

898

933

987

1076

1175

819

844

869

420

335

513

1087

832

860

893

945

1030

1125

784

808

832

444

353

551

1200

918

949

986

1043

1137

1242

866

892

918

444

353

540

1149

879

909

944

999

1089

1189

829

854

879

468

372

580

1265

968

1001

1039

1100

1199

1309

913

940

968

468

372

569

1211

927

958

995

1053

1148

1253

874

900

927

576

462

707

1490

1140

1179

1225

1296

1413

1542

1076

1108

1140

588

470

719

1521

1164

1204

1250

1323

1442

1574

1098

1131

1164

588

470

719

1521

1164

1204

1250

1323

1442

1574

1098

1131

1164

Table 7: Station Class Porcelain Arrester, Type 3EP6


(The table shows only standard arresters, other special types are available on request.)

18

p.u. MCOV
1.8
1.7

Preheating to 140F/60C
no prior duty
Preheating to 140F/60C
prior duty

1.6
1.5
1.4
1.3
1.2
1.1

t/s

1
0.01

0.1

10

100

1000

10000

Mechanical Characteristics
Short circuit
current 0.2 s

Energy
(thermal)

Creepage
distance

Height
H

Grading ring
diameter

Cantilever
strength*
(UMS-Static)

Weight

[kA]

[kJ/kV
mcov]

[inch]

[inch]

[inch]

[inch-lbf]

[lbs]

3EP6 108-2PC31-4XH5

65

10

155

51

191175

338

3EP6 111-2PC31-4XH5

65

10

155

51

191175

338

3EP6 120-2PC31-4XH5

65

10

155

51

191175

339

3EP6 132-2PC31-4XH5

65

10

155

51

191175

341

3EP6 144-2PC31-4XH5

65

10

155

51

191175

344

3EP6 168-2PD31-4XH5

65

10

177

57

191175

378

3EP6 172-2PD31-4XH5

65

10

177

57

191175

378

3EP6 180-2PF31-4XH5

65

10

229

69

191175

440

3EP6 192-2PF31-4XH5

65

10

229

69

191175

442

3EP6 228-2PG31-4XH5

65

10

249

74

191175

475

3EP6 240-2PJ31-4XH5

65

10

302

86

191175

542

3EP6 258-2PJ31-4XH5

65

10

302

86

191175

553

3EP6 258-3PJ41-4XH5

65

12.5

302

86

191175

593

3EP6 264-2PJ31-4XH5

65

10

302

86

191175

554

3EP6 264-3PJ41-4XH5

65

12.5

302

86

191175

595

3EP6 276-2PD32-4XH5

65

10

355

115

31

191175

698

3EP6 276-3PD42-4XH5

65

12.5

355

115

31

191175

741

3EP6 288-2PN32-4XH5

65

10

406

127

39

191175

766

3EP6 288-3PN42-4XH5

65

12.5

406

127

39

191175

810

3EP6 294-2PP32-4XH5

65

10

427

131

39

191175

794

3EP6 294-3PP42-4XH5

65

12.5

427

131

39

191175

840

3EP6 312-3PF42-4XH5

65

12.5

457

138

39

191175

886

3EP6 396-3PJ42-4XH5

65

12.5

604

173

47

191175

1093

3EP6 396-4PS52-4XH5

65

17.5

551

160

47

191175

1058

3EP6 420-3PJ42-4XH5

65

12.5

604

173

47

191175

1101

3EP6 420-4PJ52-4XH5

65

17.5

604

173

47

191175

1133

3EP6 444-3PF43-4XH5

65

12.5

686

207

59

191175

974

3EP6 444-4PF53-4XH5

65

17.5

686

207

59

191175

1006

3EP6 468-3PF43-4XH5

65

12.5

686

207

59

191175

983

3EP6 468-4PF53-4XH5

65

17.5

686

207

59

191175

1017

3EP6 576-4PJ53-4XH5

65

17.5

906

259

83

191175

1322

3EP6 588-4PJ53-4XH5

65

17.5

906

259

83

191175

1322

3EP6 588-4PJ57-4XH9 R4A

65

17.5

880

259

83

318627

1789

Arrester order number

* MDCL-static (Maximum design cantilever load-static) = Designed to continuously carry working load, and this applies to polymer housed arresters
UMS-static (Ultimate mechanical strength-static) = Ultimate Cantilever Strength (Design Load), and this applies to porcelain housed arresters

19

Accessories
All types are equipped with NEMA 4-hole HV-terminal and cable clamp
DIN/NEMA terminal 3EL5/1

DIN/NEMA terminal 3EL2


3.94"

1.57"

0.
55
"

1.97"

4.49"

0.
55
"
4.1"

1.6"

2.0"

3.15"

1.57"

2.0"
1.6"

0.98"

1.97"

3.15"

DIN/NEMA terminal 3EQ1/3EP4

DIN/NEMA terminal 3EQ4

3.94"
1.97"

3.94"

1.97"

4.49"

1.97"

1.57"

4.5"

"
55
0.

DIN/NEMA terminal 3EP5

1.57"

1.97"
1.57"

"
55
0.

1.57"

DIN/NEMA terminal 3EP6


3.94"
1.97"

1.97"

All dimensions in inches

20

0.
55
"

1.57"

1.97"

3.94"

1.57"

1.97"

3.15"

1.57"

4.49"

0.
55
"

1.57"

Adapter Plates for Varying Mounting Requirements


Mounting base 3EL5/1
grounded

10
7.8 .0"
7"

m
m ax.
in.
10.
7. 0"
87
"

0.5
5"

M12

2.36"

max. 0.63"

12
0

1.75"

1.97"
0.98"

1.75"

2.36"

M12

3.46"
1.5"

insulated

12
0

3xM12

Mounting base 3EL2


grounded

m
mi ax.
n.
10.8
7.8 7
1" "

10
.8
7 7"
.81
"

M12

120

120

M12

max. 0.59"

0.55"

insulated

3xM12
5"
1.7
6"
2.3

5"
1.7
6"
2.3

All dimensions in inches

21

Mounting base 3EQ1


insulated

grounded

3xM12

10.24"
11.73"

max. 0.59"

1.75"

0"
1

2.36"

M12

10.24"

max. 0.59"

1.75"

0"
1

3x1
20

2.36"

10.24"

3x1
20

10.24"
11.73"

M12

3xM12

Mounting base 3EQ4


insulated

grounded

6x 0.87"

14.96"

6x6
0

0
6x6

All dimensions in inches

22

6.3"
0.79"

4.33"

6x 0.87"

0.79"

1
0"

10"

11.8"

14.96"

11.8"

Mounting base 3EP5


insulated

11.5"
M12
1.5"

max. 0.59"

M12

0.55"

1.75"

11.5"

2.36"

10
"
7
.87
"

1.75"

m
m ax.
in.
10
7. "
87
"

0.5
5"

2.36"

grounded

11.5"

11.5"

3xM12

Mounting base 3EP4


insulated

grounded

10.24"
11.73"

3xM12

10.24"
11.73"

M12

1.18"

max. 0.59"

2.36"

0"
1

1.75"

M12

10.24"

max. 0.59"

2.36"

0"
1

3x1
20

1.75"

10.24"

3x1
20

3xM12

All dimensions in inches

23

Mounting base 3EP6


grounded

insulated

11.61"
11.97"

0.79"

0.79"

11.61"

M12

4.37"

4.37"

M12

"
10

1.75"

2.36"

6x 0.87"

6x6
0

1.75"

"
10

2.36"

6x6
0

6x 0.87"

11.97"

Accessories
All types are equipped with a cable clamp
Standard cable clamp

Grounding eye-bolt terminal for all arresters

1.75"

1.18"

0.
52
"

0.89"

3.15"
1.75"

4.13"

0,39"

2.56"

All dimensions in inches

24

0.16"

4xM12

ASME 1/2-13

min.
0
max. .59"
1.34

Monitoring devices for surge arresters


These monitoring devices can be connected to all surge arresters shown in this catalog

ACM basic

ACM advanced

Arrester Condition Monitor (ACM) basic


Order number: 3EX5 080-0
Arrester Condition Monitor (ACM) advanced
Order number: 3EX5 080-1
Order number: 3EX5 085 (USB wireless module)

Surge counter

Surge counter with


leakage current meter

Surge counter
Order number: 3EX5 030-0
Surge counter with leakage current meter
Order number: 3EX5 050-0

Sensor
Order number: 3EX5 060-1
Sensor

Display

Display
Order number: 3EX5 062-1
Connecting lead*
Order number: 3EX5 963-xx

Up to 600 ft

Connecting leads available in fixed lengths from


3 to 30 meters. You can also order a connector and
asocket and configure a connecting lead on your
own up to 600 feet.
Connector and socket
Order number: 3EX5 960-0

*Required for operation


Available in different lengths

25

Part number (example)

Silicone rubber-housed surge arrester cage design

Silicone rubber-housed surge arrester tube design

Porcelain-housed surge arrester

Surge arrester type


Rated voltage in kV

132

P M 3 1 4 X H

132

Long-duration current max. values, energy (thermal)


550 A, 4.5 kJ/kV MCOV

750 A, 6.3 kJ/kV MCOV

1100 A, 10.0 kJ/kV MCOV

1600 A, 12.5 kJ/kV MCOV

2000 A, 17.5 kJ/kV MCOV

1200 A, 12.5 kJ/kV MCOV

Application
Phase surge arrester

Neutral point surge arrester

Line surge arrester

Housing size of single unit

Number of sections
1 section

2 sections

3 sections

1 section, increased MDCL resp. UMS

2 sections, increased MDCL resp. UMS

3 sections, increased MDCL resp. UMS

Form of sheds
Standard sheds

Alternating sheds

High-voltage terminal
NEMA 4 hole pad, hot-dip galvanized

NEMA 4 hole pad, stainless steel

Name plate
English IEEE/ANSI

Mounting
3EL, 3EP5, 3 hole insulated, 8.7510.00

3EL/3EP5, 3 hole not insulated, 8.7510.00, 3EP4/6, 3EQ, 3 hole not insulated 10.00

3EQ4, 3 hole not insulated 16.5

3EP4/6/3EQ, 3 hole insulated 10.00

3EQ4, 3 hole insulated, 16.5

3EP6, 270x270 mm, insulated, increased cantilever strength

9 R4A

3EQ4, 310x310 mm, insulated, increased cantilever strength

9 R4C

The top row shows an example of the build-up on our complete part numbers.

26

GENERELL IEC STATT ANSI!!!!

Europe

North America
Burlington, Ontario
Richland, Mississippi

Oslo

Moscow

Gebze, Kocaeli

Espoo

Vienna

Athens

Dublin

Grenoble

Bucharest

Manchester

Ljubljana

Barcelona

Asia

Upplands Vsby,

Huizingen

Sofia

Almaty

Seoul

Stockholm

Bratislava

Madrid

Gurgaon

Shanghai

Den Haag

Zagreb

Amadora

Hanoi

Hong Kong

Istanbul

Berlin

Bangkok

Dhaka

Manila

Abu Dhabi

Petaling Jaya

Riyadh

Jakarta

Wuxi

El Marques, Quertaro
Santo Domingo
San Jose
Ciudad de Guatemala

Africa
South America
Bogota

Algiers
Casablanca
Tunis

Quito

Cairo

Lima

Isolo, Lagos

Santa Cruz de la Sierra

Douala

Australia

Jundia, So Paulo

Addis Ababa

Macquarie Park, NSW,

Santiago

Nairobi

Buenos Aires

Ngaliema, Kinshasa

Sydney

Ingombota Luanda
Maputo
Halfway House

Siemens Global Presence


Siemens Surge Arrester Production Center

Marking and nameplate of high-voltage surge arresters


A nameplate is installed on each high-voltage surge arrester
when it s uccessfully passes the mechanical routine test. It is
aweather- and UV-proof blue name plate placed at the flange
of a surge arrester.

27

Published by and copyright 2013:


Siemens AG
Energy Sector
Freyeslebenstrasse 1
91058 Erlangen, Germany

US Location
Siemens Energy, Inc.
Power Transmission Division
444 Highway 49 South
Richland, MS 39218
siemens.com/energy/arrester

Please contact us at:


Toll-free: +1 (877) 742-3309
Phone: +1 (601) 932-9800
Power Transmission Division
Order No. E50001-F630-A128-V3-4AUS |
Printed in Germany | Dispo 30002 |
TH 263-130349 | W | 473442 | WS | 10131.0

Printed on elementary chlorine-free bleached paper.


All rights reserved.
Trademarks mentioned in this document
are the property of Siemens AG, its affiliates,
or their respective owners.

Subject to change without prior notice.


The information in this document contains general
descriptions of the technical options available, which
may not apply in all cases. The required technical
options should therefore be specified in the contract.

Vous aimerez peut-être aussi