Vous êtes sur la page 1sur 20

A

B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1

Air-insulated
switchgear
UniGear type ZS1
-
7
0
7
4

D

1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

2
Medium voltage
technology
Medium voltage
technology
-
7
0
7
5
D

1
Air-insulated switchgear
UniGear type ZS1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

3
Medium voltage
technology
Medium voltage
technology
-
7
0
7
6
D

1
Rated voltage kV 12 17.5 24
Rated current
of the main busbars A ...4000 ... 4000 ... 2500
Rated current
of Circuit breaker panel A ...4000 ... 4000 ... 2500
Rated short-time
withstand current kA ...50 ...40 ...25
Peak withstand
current kA 125 100 63
Width mm 650/800/1000 650/800/1000 800/1000
Height mm 2200 2200 2200
Height with gas duct mm 2700 2700 2800
Dept mm 1300/1350 1300/1350 1500
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

4
Medium voltage
technology
Medium voltage
technology
Basic structure
A
D
C
E
B
F
1
2
3
4
Compartments:
1 Circuit-breaker
2 Busbar
3 Cable
4 Auxiliary
Main components:
A Busbar system
B Bushings
C Current Transformer or Combi Sensor
D Voltage Transformer
E Earthing switch
F Cable connectors
-
7
0
7
7
D

1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

5
Medium voltage
technology
Medium voltage
technology
3

-
Designed for:
Flexible applications
Complete range of apparatus: VD4, VM1, HD4, V-Contact
Operation and safety
Front, rear and sides arc resistance
Closed doors racking
Metallic shutters, connected to earth
Metallic segregation of all the compartments
Maintenance simplicity
Front service operations
Front access to all components
-
7
0
7
8
D

1
2
-
0
3
-
2
0
0
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

6
Medium voltage
technology
Medium voltage
technology
-
7
0
7
9
D

1
Apparatus
Vacuum circuit-breakers
VD4 vacuum circuit-breakers with
spring actuator
Circuit-breakers for all fields of power
distribution applications.
Even distribution of the melting points
over the whole surface of the contacts
means the best performances can be
obtained at all current values.
The epoxy resin poles protect the
interrupters from any physical and
electrical damage.
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

7
Medium voltage
technology
Medium voltage
technology
-
7
0
8
0
D

1
Apparatus
Vacuum circuit-breakers
VM1 vacuum circuit-breakers with
magnetic actuator
The vacuum circuit-breakers can also be
equipped with the magnetic actuator
operating mechanism.
The switching, latching and release
functions are integrated in the
magnetic actuator.
All the functions (release, operating, motion,
energy storage and check the functional
reliability) are operated by the integrated
electronic controller.
Equipped with multi-voltage power-supply.
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

8
Medium voltage
technology
Medium voltage
technology
-
7
0
8
1
D

1
Apparatus
SF
6
circuit-breakers
HD4 SF
6
circuit-breakers
Circuit-breakers for all fields of power
distribution applications.
Pole in SF
6
with autopuffer breaking system.
The combination of compression and self-blast
techniques means the best performances can
be obtained at all current values.
Withstanding of the insulation voltage and
breaking capacity up to 30% of the rated
breaking capacity even at
zero relative pressure.
The poles can be fitted with gas pressure
control device.
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

9
Medium voltage
technology
Medium voltage
technology
-
7
0
8
2

D

1
Apparatus
Vacuum contactors
V-Contact vacuum contactor
Optimal solution for motor starters,
power-factor correction capacitor banks
and transformer feeders up to 12 kV.
Fitted with medium voltage fuses
according to DIN and BS Standards.
Possibility of integrating a single-phase
voltage transformer to supply the
control circuits.
Availability of operating mechanism with
electrical or mechanical latching.
Equipped with multi-voltage
power-supply.
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
0
Medium voltage
technology
Medium voltage
technology
-
7
0
8
3
Bushings
1
1
2
3
1
1
Main characteristics
Single phase type
Compact and robust solution
Self-supporting branches fixing base
1 Branch connector slot
2 Fixed contacts
3 Circuit-breaker slot
1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
1
Medium voltage
technology
Medium voltage
technology
Shutters
CB compartment VTs compartment
Main characteristics
Metallic shutters
Connected to earth
Automatically operated
by the truck
Optional padlocks
open open
-
7
0
8
4
1
2
-
0
3
-
2
0
0
3

-
closed closed
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
2
Medium voltage
technology
Medium voltage
technology
Cables connections
Main characteristics
Conventional AIS cable connectors
Up to 6 cables per phase
Single or three cores cables
Up to 630 mm
2
conductor
cross section
Cable area easily accessible
from the front
-
7
0
8
5
D

1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
3
Medium voltage
technology
Medium voltage
technology
-
7
0
8
6
D

1
Both conventional transformers and
sensors technologies
The use of sensors gives the following advantages
High accuracy and linearity
Large dynamic range
Low temperature coefficient
No saturation
No iron-resonance
Compact and cost effective solution
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
4
Medium voltage
technology
Medium voltage
technology
Current transformers (...2500A)
Dimensions according to DIN 42600 standard
Narrow Type.
Electrical characteristics according to IEC 60044-1.
One set per phase, Medium or Long size
(up to 3 or 5 cores).
-
7
0
8
7
D

1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
5
Medium voltage
technology
Medium voltage
technology
Current transformers (3150...4000A)
1 2 3
-
7
0
8
8
D

1
-
0
3
-
2
0
0
3

-
Ring-core Type.
Electrical characteristics according to IEC 60044-1.
One set per phase.
2
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
6
Medium voltage
technology
Medium voltage
technology
-
7
0
8
9

D

1
Dimensions according to DIN 42600
standard Narrow Type.
Electrical characteristics according
to IEC 60044-2.
Voltage transformers
Type
Fixed
Withdrawable with fuses
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
7
Medium voltage
technology
Medium voltage
technology
-
7
0
9
0

D

1
-
0
3
-
2
0
0
3

-
Current and voltage sensors (...2500A)
Dimensions according to DIN 42600
standard Narrow Type.
Current sensors compliant
with IEC 60044-8 / CDV.
Voltage sensors compliant
with IEC 60044-7.
Main characteristics:
In the combi-sensors both current and voltage sensors are integrated in
the same compact cast resin part.
Current sensor is based on a Rogowski coil.
Voltage sensor is based on a resistive divider.
Also a capacitive divider for voltage indication is included.
2
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
8
Medium voltage
technology
Medium voltage
technology
Active arc protection system
Fast Recovery Device based on pressure sensors
for internal arc detecting and quenching.
Main characteristics:
Limit the duration of arcing to a
maximum of 100 ms.
Minimize the damage
caused by arcing.
Fault area selective control.
Pressure sensors trip directly CB.
Sensors mounted in the
auxiliary compartment.
Pressure sensors testing under
service conditions.
Pressure sensors
-
7
0
9
2
D

1
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

1
9
Medium voltage
technology
Medium voltage
technology
-
7
0
9
3
D

1
Main features
Protection
Measurement
Control
Signaling
Interlock
Automation
Communication
REF542 plus
2
-
0
3
-
2
0
0
3

-
Air-insulated switchgear UniGear type ZS1


A
B
B

P
o
w
e
r

T
e
c
h
n
o
l
o
g
i
e
s
/

2
0
Medium voltage
technology
Medium voltage
technology

Vous aimerez peut-être aussi