1
[GeoStructural Analysis - Micropile | version 5.15.13.0 | Copyright 2013 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Analysis of micropile
Input data
Project
Date : 8/24/2014
Settings
Standard - safety factors
Micropiles
Verification of stem bearing capacity :
Verification of root bearing capacity :
Verification methodology :
geometric method (Euler)
Lizzi theory
Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for critical force :
Safety factor for section resistance :
Safety factor for root bearing capacity :
SF
f
=
SF
s
=
SF
r
=
1.50
1.50
1.50
[]
[]
[]
Soil parameters
123
Unit weight :
Angle of internal friction :
Cohesion of soil :
Saturated unit weight :
g
j
ef
c
ef
g
sat
=
=
=
=
18.00
15.00
30.00
19.10
kN/m
3

kPa
kN/m
3

Geometry
Diameter
Thickness of web-section
=
=
32.0
3.0
mm
mm
Free length of pile
Root length
Diameter of root
Pile inclination from vertical
Pile head offset
l
l
r
d
r
a
l
a
=
=
=
=
=
10.50
0.01
0.32
0.00
0.50
m
m
m

m
Material parameters of structure:
1
Specified characteristic compressive strength
Elastic modulus E
b
=
=
20.68
28957.98
MPa
MPa
2
Specified characteristic strength of steel
Elastic modulus E
s
=
=
206.84
206842.72
MPa
MPa
Geological profile and assigned soils
Number
Layer
[m]
Assigned soil Pattern
1
2
20.00
-
123
123
T
r
i
a
l

l
i
c
e
n
s
e

f
o
r

t
e
s
t
i
n
g

p
u
r
p
o
s
e
s

o
n
l
y
T
r
i
a
l

l
i
c
e
n
s
e

f
o
r

t
e
s
t
i
n
g

p
u
r
p
o
s
e
s

o
n
l
y
2
[GeoStructural Analysis - Micropile | version 5.15.13.0 | Copyright 2013 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Load
Number
Force
new change
Name
Force
N [kN]
Moment
M [kNm]
1 YES Force No. 1 0.00 350.00
Ground water table
The ground water table is at a depth of 8.00 m from the original terrain.

Verification No. 1
Cross-section check -calculation no. 1
Internal stability checking: geometric method (Euler)
calculation of section effective length - bearing (hinged-hinged).

Modulus of subsoil reaction
Calculate number of halfwaves
Effective length
E
p
n
l
cr
=
=
=
10.00
8.80
0.84
MN/m
3
m
Critical normal force
Maximal normal force
N
cr
N
max
=
=
92.39
0.00
kN
kN
Safety factor = 1000.00 > 1.50
Internal stability of micropile section is SATISFACTORY
Evaluation of coupled section bearing capacity:Location of neutral axis = 1.8 mm

Stress in steel
Design strength of steel
=
=
131859.91
206.84
MPa
MPa
Safety factor = 0.00 < 1.50
Coupled section of micropile is NOT SATISFACTORY

Verification No. 1
Root evaluation - calculation number 1
Calculation method - Lizzi theory.
Coefficient of root diameter influence = 0.80
Average limit skin friction q
sav
= 0.00 kPa
Total bearing capacity of micropile root = 0.00 kN

Bearing capacity of the micropile
Maximal normal force
Q
N
max
=
=
0.00
0.00
kN
kN
Safety factor = 1000.00 > 1.50
Bearing capacity of the root is SATISFACTORY