Version Clockwise closing, counterclockwise closing
Swing angle Standard: 90 adjustable within a range of 8 ; Set in the factory to 90, unless ordered otherwise. Options: 34 50 1) , 50 66, 66 82, 98 130, 130 180; infinitely adjustable Power supply 24 V DC +/ 15 % smoothed, max. 80 mA Output signals Contactless end position switches (Hall sensors) for end positions OPEN and CLOSED Standard: 2 potential-free signal relays with one common, for signalling end position OPEN, end position CLOSED max. 250 V AC, 3 A (resistive load), min. 12 V, 10 mA Option: RWG with max. 250 V AC, 3 A (resistive load), min. 5 V, 10 mA Position feedback, analogue (options) Potentiometer: Conductive layer potentiometer 5 k/0,5 W/Linearity 0.5 % Wire wound potentiometer 5 k/1.5 W/Linearity 0.5 % Position transmitter: Electronic position transmitter RWG 0/4 20 mA in 3- or 4-wire version 4 20 mA in 2-wire version Mechanical position indicator Standard: Continuous indication Option: Adjustable indicator disc with symbols OPEN and CLOSED Heater in switch compartment Standard: Self-regulating PTC heater, 5 20 W 110 250 V DC/DC or 24 48 V DC/AC Electrical connection Standard: AUMA plug/socket connector with crimp type connection Threads for cable glands Standard: 1 x M 20 x 1.5, 1 x M 25 x 1.5 Options: Pg-threads, NPT-threads, G-threads Terminal plan APG AP301 (basic version) Service conditions Enclosure protection according to EN 60 529 1) Standard: IP 68-3, dust and water tight up to max. 3 m head of water Options: IP 68-6, dust and water tight up to max. 6 m head of water Definition IP 68: Duration of submersion in water max. 72 hours. Up to 10 operations during submersion. Corrosion protection Standard: KN Suitable for installation in industrial units, in water or power plants with a low pollutant concentration Options: KS Suitable for installation in occasionally or permanently aggressive atmosphere with a moderate pollutant concentration (e.g. in wastewater treatment plants, chemical industry) KX Suitable for installation in extremely aggressive atmosphere with high humidity and high pollutant concentration Finish coating Standard: Two-component iron-mica combination Colour Standard: grey (DB 702, similar to RAL 9007) Option: Other colours are possible on request Ambient temperature Standard: 25 C to + 80 C Options: 25 C to + 70 C (in combination with position transmitter RWG) Mounting to gearbox Standard: AUMA part-turn gearboxes GS/lever gearboxes GF with AUMA adapter Delivery for mounting to foreign gearbox without adapter or retrofit-kit Option: Subsequent mounting to AUMA part-turn gearboxes GS/lever gearboxes GF including AUMA retrofit-kit 1) Swing angle resolution limited at potentiometer 2) For version in enclosure protection IP 68, higher corrosion protection KS or KX is strongly recommended. Y000.363/002/en Technical data valve position indicator for gearboxes with swing angle < 180 WSG 90.1 Issue 1.07 We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. Page 1 of 2 Technical data RWG 3- or 4-wire system 2-wire system Output current I a 0 20 mA, 4 20 mA 4 20 mA Power supply U v 24 V DC 14 V DC + (I x R B ), max. 30 V Max. current input I 24 mA bei 20 mA Output current 20 mA Max. load R B 600 (Uv - 14 V)/20 mA Y000.363/002/en Technical data valve position indicator for gearboxes with swing angle < 180 WSG 90.1 We reserve the right to alter data according to improvements made. We reserve the right to alter data according to improvements made. We reserve the right to alter data according to improvements made. Issue 1.07 Page 2 of 2 We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. Issue 1.07 Page 2 of 2 Adapter Other information EU Directives Electromagnetic Compatibility (EMC): (89/336/EEC) Low Voltage Directive: (73/23/EEC) Machinery Directive: (98/37/EC) Reference documents Product description Part-turn gearboxes GS 50.3 GS 250.3/GS 315 GS 500 Product description Lever gearboxes GF 50.3 GF 250.3 Type Bolts Fastening torque T A [Nm] Strength class A2-70/A4-70 A2-80/A4-80 Adapter M 4 2 GS/GF 50.3 M 5 5 GS/GF 63.3 125.3 M 6 8 10 GS/GF 160.3 M 8 18 24 GS/GF 200.3 M 10 36 48 GS/GF 250.3 M 12 61 82 GS 315 500 M 12 61 82