Académique Documents
Professionnel Documents
Culture Documents
400 83.9 0.0762
400 42.1 0.3757
410 85.2 0.0695
420 85.5 0.0680 410 37.9 0.4213
430 85.7 0.0670 420 34.8 0.4584
440 85.4 0.0685
430 32.2 0.4921
450 84.9 0.0660
460 83.7 0.0773 440 30.2 0.5199
470 81.7 0.0873 450 28.3 0.5482
480 78.7 0.1040
460 27.9 0.5543
490 75.1 0.1243
500 70.4 0.1524 470 29.3 0.5331
510 68.2 0.1662 480 32.7 0.4854
520 64.1 0.1931
490 38.7 0.4122
530 65.1 0.1864
540 65.9 0.1837 500 47.6 0.3223
550 67.7 0.1694 510 58.2 0.2350
560 75.6 0.1214
520 80.2 0.0958
570 77.4 0.1112
580 85.7 0.0670 530 87.7 0.0570
590 90.2 0.0447 540 87.7 0.0570
600 91.5 0.0385
550 92.4 0.0343
610 92.1 0.0357
620 92.6 0.0333 560 93.3 0.0301
630 92.9 0.0319
640 93.4 0.0296
Realizamos dos tipos de anlisis:
1. Determinacin de la longitud ptima
de onda para poder graficar las curvas
espectrales Absorbancia vs Longitud
de onda respectivas del
permanganato y la heliantina
(Inorgnica vs Orgnica)
2. Determinacin de la concentracin
ptima de la muestra (verificar del
mismo modo la zona de trabajo).
Permite graficar la curva de
Ringbown.
Lectura del espectrofotmetro: Longitud ptima de la onda y %
Transmitancia
Lectura del espectrofotmetro: % Transmitancia
1Para poder comparar la forma de las curvas espectrales entre
dos sustancias de naturaleza distinta: Inorgnica vs Orgnica. El
procedimiento a seguir fue el desarrollado en la primera prctica:
La sustancia es colocada, junto a un patrn Agua; en el
espectrofotmetro medimos la transmitancia conforme
aumentamos la longitud de onda. El punto en el cual la
transmitancia sea la ms baja posible ser nuestra absorbancia
ms alta, es decir: La longitud ptima de la onda nos otorga la
absorbancia ms alta posible de la sustancia problema.
2 Si deseamos graficar la curva de Ringbown (la que nos permite
formar nuestra curva de calibracin) primero debemos realizar las
disolucin. Prepararemos soluciones de una concentracin (C)
desde 0.1 ug/ml, 0.2 ug/ml, 1 ug/ml, 2 ug/ml, 5 ug/ml, 10 ug/ml,
15 ug/ml, 20 ug/ml, 30 ug/ml, 200 ug/ml hasta 500 ug/ml a partir
de la solucin estndar de aseptil rojo (Azosulfamida 5%).
Con las diluciones ya hechas, procedemos a realizar las lecturas
en el espectrofotmetro. Las lecturas sern del % Transmitancia,
nuestra labor consiste en determinar la absortancia:
Para luego graficar nuestra curva
Longitud ptima de
Azosulfamida:
530 nm
Longitud ptima de
Anaranjado de metilo: 460
nm
Longitud ptima de
Permanganato:
520 nm
Absortancia vs Log (C).
Una vez que ya tenemos nuestras diluciones preparadas, podemos comenzar con las lecturas de la transmitancia.
La longitud de onda a utilizar ser: La longitud ptima de cada sustancia, 530nm para la azosulfamida y 460nm
para la heliantina. Iremos aadiendo en las cubetas del espectrofotmetro cada dilucin unitariamente. El anlisis
de la transmitancia ser llevado a cabo en la longitud ptima. Nuestros datos sern acoplados en las posteriores
tablas.
A partir de la transmitancia leda estaremos en la facultad de poder graficar la Curva de Ringbown (Absortancia vs
Log [C]).
Preparamos cada concentracin a partir de la
muestra estndar de aseptil rojo. La forma en
cmo se procedi con las diluciones est
explicada en el presente informe.
Curva de Ringbown: Absortancia vs Concentracin ~
Azosulfamida y Heliantina
En esta parte desarrollaremos la curva de Ringbown, la cual nos permite encontrar la
zona de trabajo y lo ms importante: La concentracin ptima de la muestra.
*Cabe resaltar que nuestro grupo trabaj con las diluciones de la azosulfamida
[ ]
0.1 98.6 1.4
0.2 97.8 2.2
0.4 96.7 3.3
0.6 96.0 4.0
0.8 94.4 5.6
1.0 93.0 7.0
1.5 84.7 15.3
2.0 85.1 14.9
2.5 84.2 15.8
3.0 78.8 21.2
3.5 75.1 24.6
4.0 75.6 24.4
5.0 71.9 28.1
6.0 66.1 33.9
8.0 57.7 42.3
10.0 50.7 49.3
15 38.7 61.3
20 27.5 72.5
30 11.5 88.5
40 6.4 93.6
60 0.1 99.9
80 0.0 100
100 0.0 100
200 0.0 100
[ ]
0.2 74.4 25.6
0.3 95.7 4.3
0.6 69.7 30.3
0.8 69.7 30.3
1.5 90.8 9.2
3.0 35.4 64.6
3.5 30.7 60.3
4 12.2 87.8
5 5.5 94.5
6 3.1 96.9
10 0.0 100
15 0 100
20 0 100
Azosulfamida: Sustancia estudiada
1. Tabla completa: Absortancia, Log C y % Transmitancia.
Azosulfamida
g/mL mg/mL log C % T Absortancia
0.1 100 2 98.6 1.4
0.2 200 2.30103 97.8 2.2
0.1 100 2 96.7 3.3
0.6 600 2.7781513 96 4
0.8 800 2.90309 94.4 5.6
1 1000 3 93 7
1.5 1500 3.1760913 88.3 11.7
2 2000 3.30103 85.1 14.9
2.5 2500 3.39794 84.2 15.8
3.5 3500 3.544068 75.5 24.5
4 4000 3.60206 75.6 24.4
5 5000 3.69897 71.9 28.1
6 6000 3.7781513 66.1 33.9
8 8000 3.90309 57.7 42.3
10 10000 4 50.7 49.3
15 15000 4.1760913 38.7 61.3
20 20000 4.30103 27.5 72.5
30 30000 4.4771213 11.5 88.5
40 40000 4.60206 6.4 93.6
60 60000 4.7781513 0.001 99.999
DISCUSIN DE RESULTADOS
CURVA DE RINGBOWN: AZOSULFAMIDA
Para obtener el intervalo ptimo y adecuado de concentraciones con el menor error por
lectura primero se construye la curva de Ringbown que consiste en construir una grfica
de absortancia (100%-T) vs la concentracin.
La zona lineal corresponde al intervalo de concentraciones de mnimo error, C/C, por
lectura y el punto de inflexin corresponde al valor de:
100%-%T= 49.3; T=50.7; que corresponde al valor de mnimo error.
Para la mayora de los sistemas la curva de Ringbom corresponde a una curva en forma
de S. La parte lineal de esta grfica permite obtener el intervalo de concentraciones
ptimo o el intervalo que presentara una relacin lineal entre absorbancia y
concentracin.
En esta grfica, los cruces de la parte recta (la intermedia), con la parte baja y con la
parte alta, pueden servir para determinar un valor para los lmites de deteccin mnimo y
mximo, respectivamente.
En la curva de Ringboom para la azosulfamida resulto como concentracin optima el
valor de 6.4565 g/mL as como la concentracin mnima cuantificada a 3.715 g/mL y la
concentracin mxima cuantificada a 11.2 g/mL.
0
20
40
60
80
100
120
0 1 2 3 4 5 6
A
b
s
o
r
t
a
n
c
i
a
log C
Series1
CURVA DE RINGBOWN: ANARANJADO DE METILO
La curva de Ringbom del Anaranjado de Metilo presenta una zona de trabajo de concentraciones
1 a 5 ug/ml con las absortancias respectivas de 26.8 y 94.5 respectivamente. Adems la
concentracin ptima es de 2.2 ug/ml. No pudiendo comparar estos datos debido a que no
encontramos informacin bibliogrfica sobre el tema.
BIBLIOGRAFIA
Skoog Douglas, Principios de anlisis instrumental. 6ta edicin. 2007
Qumica analtica instrumental I Precisin en espectrofotometra. 2007. URL:
http://depa.pquim.unam.mx/amyd/archivero/Documento_de_Apoyo:_Precisi
on_en_espectrofotometria_2598.pdf
Universidad Nacional de Colombia. Establecimiento de un mtodo
espectrofotomtrico.URL:http://www.virtual.unal.edu.co/cursos/ciencias/200
1184/lecciones/Cap10/01_01_01.htm