Vous êtes sur la page 1sur 6

Windows PE 2.

0 is included in the Windows Automated Installation Kit WAIK


- Download WAIK (about 1 GB)
http://www.microsoft.com/downloads/details.aspx?familyid=C7D4BC6D-15F3-4284-9123
-679830D629F2&displaylang=en
- Follow the instructions in the WAIK guide to create PE 2.0 files (folder ISO i
s about 185 MB)
- Copy the contents of the "ISO" folder created in the proceding step to the roo
t of your USB stick
- You may Add imagex.exe for Imaging Purposes
In Command Window - Create PE 2.0 and copy imagex.exe Using:
copype.cmd x86 c:\winpe_x86
copy c:\program files\Windows AIK\Tools\x86\imagex.exe c:\winpe_x86\iso\
History Of Changes
The Volkov Commander, Versions 4.00.036 - 4.05
Changes in version 4.00.036 beta
- Global VC.EXT was not being renewed in the RAM after editing.
So you had to exit VC and then start again VC to load new
global VC.EXT.
- The panels were not being rescaned after Rename/Move of one
file with Ctrl-F6.
- If option "Auto directory sizes" was switched on and choose
sort by size, directories were sorted but after any rescan of
the panels the sorting disappeared.
- Any control symbols is possible to input using Alt-NumPad
without Ctrl-Q.
- Commands from History with control symbols are being renewed
correctly.
- There was no trace of repeated commands in History if they
were initiated by pressing of the first symbols in the command
line and press Ctrl-Enter.
- Fast mouse reset is working in a proper way.
- Volume labels on the network disks is indicated properly.
- Trying to create/change/remove Volume labels on the network
disks is blocked.
- Errors 'Sharing violation' and 'Lock violation' are treated
correctly.
- All files for reading are opened now in Deny None mode instead
of compatibility mode. This allows to read just opened for
writing files in multitask environment or in the network.
- Running under DesqVIEW extra processor time is given to other
tasks when star sky screen saver is active. Previously it was
only during enter expectation.
- Found text containing Tab symbols in viewer is highlighted
correctly.
- Mistypings in Help in chapter 'Keyboard reference' is avoided:
Cursor movement - Word right - ^F (previously it was ^T).
Changes in version 4.00.037 beta
- Added russian Help: file VCR.HLP has to be renamed to VC.HLP.
- It is possible to switch off the TSR manager to avoid
conflicts with some programs. One byte shall be changed in
VC.INI:
01C1: 01 -> 00
- Error prompts during Copy/Rename/Move have Ok/Cancel menu. If
the choice is Ok so the following file will be treated (as it
was in former version), Cancel stops group operation (it was
done for Delete and File attributes before).
- Pressing Ctrl-Break does not lead to ^C presence on the screen
before command execution.
- If directory had long file (number of located clusters more
than 65535, the situation is unreal but possible) so after
pressing Ctrl-L the computer crashed during Info-panel output.
- Computer crashed after starting external viewers with some VGA
cards.
- Pressed keys recognition algorithm is changed. Now Ctrl-Y and
Ctrl-Z work on German keyboards, and Ctrl-J = Ctrl-Enter.
- Some errors in the Help are corrected.
Changes in version 4.00.038 beta
- Ctrl-[ and Ctrl-] inserts into command line full pathname of
the left or right panel.
- The environment variable TEMP=..., if defined, sets the
directory to create list file VC.LST in.
- File names containing characters from national alphabets will
be reflected in a right way (small letters), if parameter
COUNTRY=... in CONFIG.SYS is set correctly.
- Cursor does not skip to 255-th file in panel after starting of
any program if there are more than 256 files in the directory.
- Avoided error defining the size of selected files in the Mini
Status string.
Changes in version 4.00.039 beta
- Program VCSETUP was added to install different parameters of
configuration, screen, mouse, panels, color change.
- Corrected error in the TSR manager which led to the conflict
between VC and some other programs using DPMI.
- Subdirectories are being copied with attributes.
- Most of dialog boxes appearing during copy, rename, remove and
attributes setting now have item [Cancel] to interrupt
execution of group operation.
- Added operation Append in moving file in the range of one
logical drive.
- When splitting long files, first part has date and time of
original file, other parts have current date and time. This
allows to identify the correct sequence during the pasting of
the obtained parts.
- Corrected error in long files splitting under DR-DOS.
- All new files after copy and files changed during editing will
have attribute Archive.
- To load into UMB instead of 75 Kb, 65 Kb are needed.
- The load into UMB is supported with HILOAD command in DR-DOS.
- Memory info uses information from MCB about loaded programs
for DR-DOS.
- In DR-DOS disks labels are shown correctly.
- In File Find the template *.* is added to input filename only
if the extension is absent (there is no '.').
- The date did not change at 24:00 p.m. if screen saver (star
sky) was on the screen at the moment.
- Added function Rescan (F2) in the Change Directory mode
(Alt-F10).
- Checksum of the file TREEINFO.NCD formed incorrectly if the
number of directories was more than 255.
- Added new option "Auto rescan tree" to switch off automatic
tree rescan after each creation, removing or renaming of
subdirectories. File VC.INI is increased on 1 byte.
- Disk reading error dialog box accepted some ASCII characters
in range 128-255 as drive letter in the former version.
- Algorithm of available disks determination is changed.
- If the DOS command line was in the last screen string so
switching Key Bar left mouse cursor copy.
- In some cases diskette rescanning with Ctrl-R led to file
pointer did not set on the first file in panel.
- Ctrl-\ now rescans disk even if the root directory is current.
- Symbols ! and !.! in the User Menu substitute the name of
current file or directory from the file panel. Previously this
function worked only on files.
- Error in viewer while shifting text to the left or right using
mouse.
- Saving file in the editor, it is possible to use device name
as output file name (for instance PRN or LPT2).
Changes in version 4.00.040 beta
- In speed-search mode left button press led to execution of the
command ^A, right button ^B, middle button - ^D.
- Corrected error in switching to the EGA-lines mode, when
current page is not zero.
- Running under DesqView with switched off virtualization,
output always was to zero screen page, even it was not
current.
- Option Key Bar in VCSETUP was out of order.
- In the string Key Bar, text was F10-LapTop instead of F10-Quit.
- While trying to change the Shadow presentation the computer
crashed.
Changes in version 4.00 shareware (May-9-1994)
- Autorepeat for Ins key.
- All files are opened in Deny None mode for reading. If access
is denied then trying to open in Compatibility mode.
- Small impovement in copying: long files are copied faster.
- Fixed problem in copying subdirectories on some networks.
- Fixed uncompatibility which prevented moving files from
network drives.
- Ctrl-F6 sets name of highlited file or subdirectory as default
target name to edit.
- Fixed error in deleting of not empty subdirectories under
Windows NT.
- Removed supporting of NC.MNU files as local user menus.
- Items 'Send files', 'Send/Receive mail', 'Commander mail' are
removed from the pull-down menu.
- Size of file up to 4 Gbytes is shown correctly in the internal
viewer.
- While saving file in the Editor, set attributes error is
ignored.
- Fixed error in scanning directory tree when the root directory
is unaccessable.
- Fixed error in File Find by contents. The field 'Containing'
is treated now as text string. Previously it was treated also
as hexadecimal sequence in some cases.
- CD-ROM drives now excluded from searching when *: has been
specified to find files on all fixed drives.
- Fixed error in Find File. Find buffer overlaped next memory
control block if too many files were found.
- Fixed error in TSR manager. There were string operations with
undefined direction flag in INT 21h AH=49h handler.
- Critical error handler was changed. Some error messages were
added.
- Extra processor time is given to other tasks while running
under Windows.
- When COMMAND.COM is not found, all attempts to retry were
unsuccessful. This problem is corrected.
- Added option 'Show logical drive B:' in VCSETUP program. It
enables or disables appearance of letter 'B' in Change Drive
dialog box on PCs with one floppy drive.
- While trying to set the 'Auto change dir delay time' to 1.00
in VCSETUP the computer crashed.
- Some items in color setup of VCSETUP program were mixed.
- Added help in VCSETUP program.
- Some errors in the Help are corrected.
- Added english documentation VCINFO.DOC and VCNEWS.DOC.
Changes in version 4.01 shareware (March-21-1996)
- The character in upper left corner was a blank in EGA-lines
mode.
- The list of support sites in REGISTER.DOC was changed.
Changes in version 4.02 shareware (October-09-1999)
- Tree, Volume label, Memory info, Directory sizes and Find file
functions highlights item in menu bar correctly.
- Fixed error setting dates after year 2000 in File attributes
function.
- Functions F10 and Alt-F10 in Copy/Move dialog box are swapped.
- Fixed error bringing up warning under Windows 95 when opening
zooming boxes in VC and VCSETUP.
- VC is not terminated if running under DOS older than 3.20.
- VCSETUP is not terminated if running under DOS older than 3.0.
- Error output messages about incorrect DOS version and memory
usage in VCSETUP.
- Maximal number of directories in tree panel is changed from
512 to 768.
- Some functions are mixed if type next hot keys from pull-down
menu: Gray +, Gray -, Gray *, Ctrl-M, F10.
- Fixed problem running VC and VCSETUP in text video modes if
number of columns is not 80.
- Changed '^M' to 'Ctrl-M' in 'Restore selection' line of
pull-down menu 'Files'.
- Hotkey for function 'Restore selection' in pull-down menu is
changed from 'T' to 'S'.
- Removed hot keys Ctrl-A and Ctrl-F which were equal to
Ctrl-Left and Ctrl-Right.
- Added hot key Ctrl-F for calling 'Filter' dialog box.
- Added hot key Ctrl-H for showing hidden and system files.
- Added hot key Ctrl-A for calling 'File attributes' dialog box.
- Added hot key Ctrl-C for comparing directories.
- Added Word Star hot heys in editor.
- Added hot key F3 (Quit) in internal viewer that is equal to
F10 or Esc.
- Removed handler 'Divide overflow'.
- Command line overlaps clock and menu bar if it is in first
line.
- Ctrl-Enter inserts file to command line after '@' symbol.
- Format of 'Blocks' field in Memory info dialog box is changed
from 3 to 5 digits.
- Cursor is large in the internal editor when 'Laptop' colors is
used.
- After splitting a file, date and time of first part of file is
set incorrectly if first floppy disk has no free space.
- Reading panel with directory deleted from another session
under Windows 95 causes hanging.
- 'Go to' function in 'Find File' dialog box sometimes rereads
current panel if no files were found.
- Current file is displayed in status line of 'Find File' dialog
box during searching by contents.
- Error displaying lines in editor if file contains 0Dh 0Ah 0Dh
sequence.
- Switching 'Memory allocation' option in VCSETUP causes hanging
if TSR manager in loaded VC is on.
- Fixed problem exiting from VC if critical error occurs during
loading command processor or VC.COM when TSR manager is on.
Changes in version 4.03 shareware (October-24-1999)
- Function 'File Attributes' sets dates with year 2080...2099
instead of 1980...1999.
- Format of year in function 'File Attributes' is changed from
2-digit to 4-digit.
- Format of year in function 'Find File' is changed from 2-digit
to 4-digit and seconds are added in time format.
- Added hotkey Enter for switching text or hexadecimal mode in
internal viewer (equal to F4).
- File pointer lose its position after calculating directory
sizes by Alt-F6 if panel is sorted by size.
- Arrow is displayed in editor after last line if there is no
line feed at the end of this line and column offset is not 0.
- Corrected some mistakes in Help.
Changes in version 4.04 shareware (May-21-2000)
- Garbage appears on screen after calculating directory sizes if
one of panels is off.
- Menu name does not displayed in error message of User Menu
function if VC.MNU has 0 size.
- Call Copy/Move/Delete functions via pull-down menu just after
start of VC sometimes process only single file under cursor
even if some files were selected.
- 'Find File' function works incorrectly if mask is longer than
12 characters and its part before extension is longer than 8
characters.
- The following sequence allows to view more than 100% of file
contents in internal viewer: End, search something in the last
line, Up, PgDn.
- Path of panel displays root directory after changing drive and
current path of new drive contains long entries.
Changes in version 4.05 shareware (June-16-2000)
- Main user menu (Shift-F2) did not work.
- Incorrect size of the last memory block is displayed in
'Memory information' window (Alt-F5).
- PgUp does not work in the internal viewer after searching
string at the last line of a file.
Create wimscript.ini file in Root of USB_Drive
Using Imagex.exe after Booting from Windows PE 2.0:
Image Backup:
imagex.exe /compress fast /capture c: d:\WIM_XP\xpimage.wim "mijn XP-installatie
" /verify
Image Restore:
imagex.exe /apply d:\WIM_XP\xpimage.wim 1 c:

Vous aimerez peut-être aussi