l/ow Meters ond l/ow contro//ers


CORIOLIS MASS FLOW METERS
CPlM-8800
INPUT / OUTPUT
4 - 20mA
Pulse
Local Dlsplay
ACCURACY
Accuracy = {1% of rate + Z.O.S.}
WETTED MATERIAL
PFA- avallable ln all models
PEEK-avallable ln models
8808-1 and 8808-2

- Hlghly corroslve chemlcals
- Slurry and Chemlcals contalnlng bubbles
- Flulds wlth varylng denslty and vlscoslty
- CMP slurrles or solutlons contalnlng solld contents
- Surfactants

- Mass flow callbratlon ls fluld lndependent ellmlnatlng
the need to callbrate on dlfferent flulds
- Accuracy ls unaffected by flow reglme (e.g., lamlnar
or turbulent flow) or varlatlons ln flow veloclty proflle.
- Operates and measures two-phase flow condltlons wlth
gas volumetrlc vold functlons ln excess of 30%.
FEATURES
(non-invasive)

8803-1 12 to 1,500*(g/mln)
8803-2 15 to 4,000*(g/mln)
8804-1 30 to 2,000*(g/mln)
8804-2 60 to 5,000*(g/mln)
8806-1 100 to 5,000*(g/mln)
8806-2 200 to 8,500*(g/mln)
8808-1** 300 to 13,200*(g/mln)
8808-2** 750 to 24,000*(g/mln)

8803-1 0.36 ( g / ml n )
8803-2 0.45(g/mln)
8804-1 2. 0(g /ml n)
8804-2 10.0 ( g / ml n )
8806-1 12.0 ( g / ml n )
8806-2 15.0 ( g / ml n )
8808-1** 15.0 (g/mln)
8808-2** 20.0 (g/mln)
*Pressure drop at Max. Flow range = 10 PS on water (1cP)
APPLICATIONS
CONNECTION TYPES
Tube ends, Flare, Plllar
MODEL FLOW RANGE MODEL / ZERO OFFSET STABILITY
U.S. Patent 8404076, Addltlonal Patents Pendlng
2014 Malema Sensors.
M-2111 llM
M-1500P
1/4" 0 to 3.0 L/Mln
3/8" 0 to 8.0 L/Mln
1/2" 0 to 20.0 L/Mln
3/4" 0 to 50.0 L/Mln
1" 0 to 80.0 L/Mln
CONNECTION TYPES
Tube ends and other custom optlons
WETTED MATERIAL
PFA
OUTPUT
4 - 20mA
0 - 10 VDC
Pulse
Dlsplay
ACCURACY
+/- 1% of Reading
1/4" 0 to 3.0 L/Mln
3/8" 0 to 8.0 L/Mln
1/2" 0 to 20.0 L/Mln
3/4" 0 to 50.0 L/Mln
1" 0 to 80.0 L/Mln
CONNECTION TYPES
Tube ends and other custom optlons
WETTED MATERIAL
PFA
OUTPUT
4 - 20mA
0 - 10 VDC
Pulse
Dlsplay
ACCURACY
+/- 1% of Reading
ULTRASONIC FLOW METERS
TUBE SIZES / FLOW RANGES
1/8" 0 to 600 ml/Mln
ACCURACY
+/- 2% of Readlng
OUTPUT
4 - 20mA
0 - 10 VDC
Pulse(frequency)
Pulse (Volume)
(non-invasive)
WETTED MATERIAL
PFA
CONNECTION TYPES
Tube ends and other custom optlons
TUBE SIZES / FLOW RANGES TUBE SIZES / FLOW RANGES
U.S. Patent No:6055868
& 5974897
2014 Malema Sensors.
BENEFITS
M-2500 M-1800
ULTRASONIC FLOW METERS
M-2511
- NO MOVING PARTS
- FOR ULTRA PURE WATER AND CHEMICALS
- CE-MARKING
- SIMPLE AND COMPACT
- LOW PRESSURE DROP
- LINEAR OUTPUT
ACCURACY
+/-1% of Set Polnt

TUBE SIZES / FLOW RANGES
1/4" or 3/8" : 3L/mln

WETTED MATERIAL
PFA/PTFE or PFA/Pt cured slllcone
INPUT / OUTPUTS
0 - 10 VDC
4 -20mA

ACCURACY
+/-2% of Set Polnt

TUBE SIZES / FLOW RANGES
1/4", 3/8",1/2", 3/4", 1", 1 1/8"
4L/mln to 250L/mln

CONNECTION TYPES
Tube ends, Flare, Plllar
WETTED MATERIAL
Hlgh Purlty PFA
INPUT / OUTPUTS
0 - 10 VDC
4 -20mA

CONNECTION TYPES
Tube ends, Flare, Plllar
ACCURACY
+/-3% of Set Polnt

Non-lnvaslve Inllne DSP
Ultrasonlc Flowmeter
TUBE SIZES / FLOW RANGES
1/4" or 1/8" : 750mL/mln to 3000 L/mln

CONNECTION TYPES
Tube ends, S300 Plllar unlon ends
WETTED MATERIAL
Hlgh Purlty PFA
INPUT / OUTPUTS
0 - 10 VDC
4 -20mA

Non-lnvaslve Inllne DSP
Ultrasonlc Flowmeter
DSP Ultrasonlc Flowmeter
ln an Integrated Package
FA8T RE8PON8E
HANDLE8 ENTRANED BUBBLE8
CORRO8ON RE88TANT
8UTABLE FOR 8LURRY AND CHEMCAL8

2014 Malema Sensors.

3/8" 0.4 to 4.0 L/Mln


1/2" 2.0 to 20.0 L/Mln
3/4" 5.0 to 50.0 L/Mln
1" 10.0 to 100.0 L/Mln
CONNECTION TYPES
Tube, Flare, Plllar
WETTED MATERIAL
PFA
OUTPUT
4-20mA
Pulse
Local Dlsplay
3/8" 0.5 to 4.0 L/Mln
1/2" 2.0 to 16.0 L/Mln
3/4" 4.0 to 40.0 L/Mln
1" 10.0 to 150.0 L/Mln
CONNECTION TYPES
RC / Other optlons avallable
WETTED MATERIAL
PPS
OUTPUT
4-20mA
Pulse
Local Dlsplay
1/4" 0.1 to 5.0 L/mln
3/8" 1.0 to 30.0 L/Mln
1/2" 4.0 to 50.0 L/Mln
3/4" 20.0 to 115.0 L/Mln
1" 38.0 to 225.0 L/Mln
CONNECTION TYPES
FNPT, Flare
BODY MATERIALS*
Celcon, PTFE, 316SS
- NO MOVING PARTS
- FOR ULTRA PURE WATER AND CHEMICALS
- CE-MARKING
- SIMPLE AND COMPACT
- LOW PRESSURE DROP
- LINEAR OUTPUT
BENEFITS
TUBE SIZES / FLOW RANGES TUBE SIZES / FLOW RANGES TUBE SIZES / FLOW RANGES
VORTEX AND PADDLE WHEEL FLOW METERS
vl-8200 vl-8100
2014 Malema Sensors.
FLOW SWITCHES - FIXED SET POINT TYPE
2014 Malema Sensors.
FIELD ADJUSTABLE FLOW SWITCHES AND RELIEF VALVES
2014 Malema Sensors.
CMlC-9000
Integrated closed loop controller for chemlcal and slurry appllcatlons
MMUNTY TO ENTRANED GA8 UP TO 30% BY VOLUME
RE8PON8E NDEPENDENT TO PHY8CAL & CHEMCAL PROPERTE8
TUBE SIZES
1/4" and 3/8"
CONNECTION TYPES
Tube ends, Flare, Plllar
INPUT / OUTPUTS
4 - 20mA, 0 - 10 VDC

ACCURACY
3% of the set polnt
(Improved accuracles avallable)
WETTED MATERIAL
PFA/PTFE or PFA/Pt cured slllcone

- Hlghly corroslve chemlcals
- Slurry and Chemlcals contalnlng bubbles
- Flulds wlth varylng denslty and vlscoslty
- CMP slurrles or solutlons contalnlng solld contents
- Surfactants
FLOW RANGES
Startlng from 5 g/mln to 5000 g/mln
APPLICATIONS
CORIOLIS MASS FLOW CONTROLLERS

U.S. Patent 8404076, Addltlonal Patents Pendlng


2014 Malema Sensors.
MlC-8100 LlC-7300
ULTRASONIC FLOW CONTROLLERS
FA8T RE8PON8E
HANDLE8 ENTRANED BUBBLE8
CORRO8ON RE88TANT
8UTABLE FOR 8LURRY AND CHEMCAL8
ACCURACY
+/-3% of Set Polnt

Integrated Closed Loop Flow Controller
for Chemlcal and Slurry Appllcatlons
TUBE SIZES / FLOW RANGES
1/4" or 3/8" : 5mL/mln to 5 L/mln

WETTED MATERIAL
PFA/PTFE or PFA/Pt cured slllcone
INPUT / OUTPUTS
0 - 10 VDC
4 -20mA

ACCURACY
+/-3% of Set Polnt

Integrated Closed Loop Flow Controller
for Chemlcal and Slurry Appllcatlons
TUBE SIZES / FLOW RANGES
1/4" or 3/8" : 5mL/mln to 5 L/mln

CONNECTION TYPES
Tube ends, Flare, Plllar
WETTED MATERIAL
PFA/PTFE or PFA/Pt cured slllcone
INPUT / OUTPUTS
0 - 10 VDC
4 -20mA


*An Optlonal shut off valve can be lntegrated.

*other models avallable wlth flow
ranges up to 40 L/mln.
CONNECTION TYPES
Tube ends, Flare, Plllar
2014 Malema Sensors.
Mll
MALEMA INTERCONNECT INTERLOCK DEVICE
BENEFITS
- Improves tool up tlme by preventlng cross contamlnatlon from occurrlng
- Provldes early lndlcatlon of unrellable valve operatlon ensurlng that the bulk supplles
cannot be contamlnated durlng unplanned or unexpected pressure fluctuatlons occurrlng
durlng normal operatlons.



- All Hlgh-purlty PTFE and PFA constructlon of the wetted components
- Integrated deslgn for compact, space savlngs lnstallatlon
- Deslgned for mlnlmal head loss
- Fleld conflgurable flare connectlons [Inlets and Outlets can be conflgured as elther 1/4" or 3/8"
flare nlpples] allowlng for slmpllfled retroflt lnstallatlon and reduced lnventorles
- Valve components tested to over 10,000,000 cycles ln DIW (over 1,050,000 ln Slurrles)
- Valve Cv = 0.8
- Bullt-ln leak detectlon & monltorlng
FEATURES
DETECT8 LEAK8 N VALVE 8EAL8 AND PREVENT8
CRO88 CONTAMNATON OF THE FLUD8
U.S. & Other Patents Pendlng
* For more detalls contact factory.

2014 Malema Sensors.
DISPENSE VERIFICATION METER
MM-3000

- Improves users capablllty to measure and monltor lmportant process varlables
- Instant verlflcatlon of "out-of-spec" dlspense
- Ellmlnates wasteful chemlcal use
- Improves product yleld
- Reduces labor assoclated wlth manual gravlmetrlc or volumetrlc dlspense verlflcatlons
* For more detalls contact factory.
BENEFITS
FEATURES
- Dlrectly reports dlspensed volume from mlcro-llter to llter
- Analog output and two user-speclfled alarm llmlts
- Transducer, electronlcs and software that easlly lntegrates lnto exlstlng dlspense system
VERY HGH ACCURACY ON NDVDUAL D8PEN8E8
OUCK RE8PON8E
U.S. Patent No:8185237

2014 Malema Sensors.
WesLern reglon offlce,uSA
MALLMA SLNSCkS CALIICkNIA
222S,MarLln Avenue, S1L. l,
SanLa Clara, CA - 9S0S0
Cfflce: +1-408-970-3419
lax:+1-408-970-3426
nP 8rochure-0/2014
PeadquarLers uSA
MALLMA SLNSCkS, USA
1060 S. 8ogers Clrcle
8oca 8aLon, lL 33487
1oll lree: 1800-637-6418
Cfflce: +1-S61-99S-0S9S
lax:+1-S61-99S-0622
MALLMA SLNSCkS, 1AIWAN
9l, no.6 Lane 131
WenShan 8d., Cyonglln Shlng
Pslnchu CounLy 307
1alwan (8.C.C)
Cfflce: +886-912-090-929
Asla aclflc PeadquarLers
MALLMA SINGACkL 1L L1D
29 Woodlands lndusLrlal ark L1
norLhLech Lobby 1, #02-06
Slngapore 7S7716
Cfflce: +6S-6482-3S33
lax:+6S-6484-4231
MALLMA SLNSCkS kCkLA
Cheongmyeong 1ownLel 808-ho,
Cheongmyeong - 8C 7
?eongLong-Cu
Suwon-ClLy, Cyeonggl-uo,
korea 443-470
Cfflce: +82-31-203-106S
lax:+82-31-203-S06S
2014 Malema Lnglneerlng CorporaLlon. All rlghLs reserved.

Malema, Malema Sensors and Malema Lnglneerlng CorporaLlon are servlce marks of Malema Lnglneerlng CorporaLlon. All oLher Lrademarks are properLy of Lhelr
respecLlve owners.


lor a compleLe llsL of conLacL lnformaLlon, please vlslL: www.malema.com
Malema endeavors Lo provlde lLs cusLomers wlLh sLaLe-of-Lhe-arL flow
and pressure measuremenL and closed-loop flow conLrol producLs.
We supporL Lhese endeavors wlLh a mulLl-faceLed englneerlng Leam LhaL
speclallzes ln provldlng cusLom soluLlons Lo meeL cusLomer requlremenLs.
Cur goal ls Lo malnLaln lasLlng and saLlsfylng cusLomer relaLlonshlps by
dellverlng a quallLy producL aL a compeLlLlve prlce and lead-Llme.
ln addlLlon Lo hlgh-purlLy producLs, Malema has a compleLe llne of
lndusLrlal producLs whlch can be vlewed aL www.malema.com
Malema supplles Lhls publlcaLlon for lnformaLlonal purposes only. Whlle every efforL has been made Lo ensure accuracy, Lhls publlcaLlon ls noL lnLended Lo make
performance clalms or process recommendaLlons. Malema does noL warranL, guaranLee, or assume any legal llablllLy for Lhe accuracy, compleLeness, Llmellness,
rellablllLy, or usefulness of any lnformaLlon, producL, or process descrlbed hereln. We reserve Lhe rlghL Lo modlfy or lmprove Lhe deslgns or speclflcaLlons of our
producLs aL any Llme wlLhouL noLlce. lor acLual producL lnformaLlon and recommendaLlons, please conLacL your local Malema represenLaLlve.