CORIOLIS MASS FLOW METERS CPlM-8800 INPUT / OUTPUT 4 - 20mA Pulse Local Dlsplay ACCURACY Accuracy = {1% of rate + Z.O.S.} WETTED MATERIAL PFA- avallable ln all models PEEK-avallable ln models 8808-1 and 8808-2
- Hlghly corroslve chemlcals - Slurry and Chemlcals contalnlng bubbles - Flulds wlth varylng denslty and vlscoslty - CMP slurrles or solutlons contalnlng solld contents - Surfactants
- Mass flow callbratlon ls fluld lndependent ellmlnatlng the need to callbrate on dlfferent flulds - Accuracy ls unaffected by flow reglme (e.g., lamlnar or turbulent flow) or varlatlons ln flow veloclty proflle. - Operates and measures two-phase flow condltlons wlth gas volumetrlc vold functlons ln excess of 30%. FEATURES (non-invasive)
8803-1 12 to 1,500*(g/mln) 8803-2 15 to 4,000*(g/mln) 8804-1 30 to 2,000*(g/mln) 8804-2 60 to 5,000*(g/mln) 8806-1 100 to 5,000*(g/mln) 8806-2 200 to 8,500*(g/mln) 8808-1** 300 to 13,200*(g/mln) 8808-2** 750 to 24,000*(g/mln)
8803-1 0.36 ( g / ml n ) 8803-2 0.45(g/mln) 8804-1 2. 0(g /ml n) 8804-2 10.0 ( g / ml n ) 8806-1 12.0 ( g / ml n ) 8806-2 15.0 ( g / ml n ) 8808-1** 15.0 (g/mln) 8808-2** 20.0 (g/mln) *Pressure drop at Max. Flow range = 10 PS on water (1cP) APPLICATIONS CONNECTION TYPES Tube ends, Flare, Plllar MODEL FLOW RANGE MODEL / ZERO OFFSET STABILITY U.S. Patent 8404076, Addltlonal Patents Pendlng 2014 Malema Sensors. M-2111 llM M-1500P 1/4" 0 to 3.0 L/Mln 3/8" 0 to 8.0 L/Mln 1/2" 0 to 20.0 L/Mln 3/4" 0 to 50.0 L/Mln 1" 0 to 80.0 L/Mln CONNECTION TYPES Tube ends and other custom optlons WETTED MATERIAL PFA OUTPUT 4 - 20mA 0 - 10 VDC Pulse Dlsplay ACCURACY +/- 1% of Reading 1/4" 0 to 3.0 L/Mln 3/8" 0 to 8.0 L/Mln 1/2" 0 to 20.0 L/Mln 3/4" 0 to 50.0 L/Mln 1" 0 to 80.0 L/Mln CONNECTION TYPES Tube ends and other custom optlons WETTED MATERIAL PFA OUTPUT 4 - 20mA 0 - 10 VDC Pulse Dlsplay ACCURACY +/- 1% of Reading ULTRASONIC FLOW METERS TUBE SIZES / FLOW RANGES 1/8" 0 to 600 ml/Mln ACCURACY +/- 2% of Readlng OUTPUT 4 - 20mA 0 - 10 VDC Pulse(frequency) Pulse (Volume) (non-invasive) WETTED MATERIAL PFA CONNECTION TYPES Tube ends and other custom optlons TUBE SIZES / FLOW RANGES TUBE SIZES / FLOW RANGES U.S. Patent No:6055868 & 5974897 2014 Malema Sensors. BENEFITS M-2500 M-1800 ULTRASONIC FLOW METERS M-2511 - NO MOVING PARTS - FOR ULTRA PURE WATER AND CHEMICALS - CE-MARKING - SIMPLE AND COMPACT - LOW PRESSURE DROP - LINEAR OUTPUT ACCURACY +/-1% of Set Polnt
TUBE SIZES / FLOW RANGES 1/4" or 3/8" : 3L/mln
WETTED MATERIAL PFA/PTFE or PFA/Pt cured slllcone INPUT / OUTPUTS 0 - 10 VDC 4 -20mA
*other models avallable wlth flow ranges up to 40 L/mln. CONNECTION TYPES Tube ends, Flare, Plllar 2014 Malema Sensors. Mll MALEMA INTERCONNECT INTERLOCK DEVICE BENEFITS - Improves tool up tlme by preventlng cross contamlnatlon from occurrlng - Provldes early lndlcatlon of unrellable valve operatlon ensurlng that the bulk supplles cannot be contamlnated durlng unplanned or unexpected pressure fluctuatlons occurrlng durlng normal operatlons.
- All Hlgh-purlty PTFE and PFA constructlon of the wetted components - Integrated deslgn for compact, space savlngs lnstallatlon - Deslgned for mlnlmal head loss - Fleld conflgurable flare connectlons [Inlets and Outlets can be conflgured as elther 1/4" or 3/8" flare nlpples] allowlng for slmpllfled retroflt lnstallatlon and reduced lnventorles - Valve components tested to over 10,000,000 cycles ln DIW (over 1,050,000 ln Slurrles) - Valve Cv = 0.8 - Bullt-ln leak detectlon & monltorlng FEATURES DETECT8 LEAK8 N VALVE 8EAL8 AND PREVENT8 CRO88 CONTAMNATON OF THE FLUD8 U.S. & Other Patents Pendlng * For more detalls contact factory.
2014 Malema Sensors. DISPENSE VERIFICATION METER MM-3000
- Improves users capablllty to measure and monltor lmportant process varlables - Instant verlflcatlon of "out-of-spec" dlspense - Ellmlnates wasteful chemlcal use - Improves product yleld - Reduces labor assoclated wlth manual gravlmetrlc or volumetrlc dlspense verlflcatlons * For more detalls contact factory. BENEFITS FEATURES - Dlrectly reports dlspensed volume from mlcro-llter to llter - Analog output and two user-speclfled alarm llmlts - Transducer, electronlcs and software that easlly lntegrates lnto exlstlng dlspense system VERY HGH ACCURACY ON NDVDUAL D8PEN8E8 OUCK RE8PON8E U.S. Patent No:8185237
Malema, Malema Sensors and Malema Lnglneerlng CorporaLlon are servlce marks of Malema Lnglneerlng CorporaLlon. All oLher Lrademarks are properLy of Lhelr respecLlve owners.
lor a compleLe llsL of conLacL lnformaLlon, please vlslL: www.malema.com Malema endeavors Lo provlde lLs cusLomers wlLh sLaLe-of-Lhe-arL flow and pressure measuremenL and closed-loop flow conLrol producLs. We supporL Lhese endeavors wlLh a mulLl-faceLed englneerlng Leam LhaL speclallzes ln provldlng cusLom soluLlons Lo meeL cusLomer requlremenLs. Cur goal ls Lo malnLaln lasLlng and saLlsfylng cusLomer relaLlonshlps by dellverlng a quallLy producL aL a compeLlLlve prlce and lead-Llme. ln addlLlon Lo hlgh-purlLy producLs, Malema has a compleLe llne of lndusLrlal producLs whlch can be vlewed aL www.malema.com Malema supplles Lhls publlcaLlon for lnformaLlonal purposes only. Whlle every efforL has been made Lo ensure accuracy, Lhls publlcaLlon ls noL lnLended Lo make performance clalms or process recommendaLlons. Malema does noL warranL, guaranLee, or assume any legal llablllLy for Lhe accuracy, compleLeness, Llmellness, rellablllLy, or usefulness of any lnformaLlon, producL, or process descrlbed hereln. We reserve Lhe rlghL Lo modlfy or lmprove Lhe deslgns or speclflcaLlons of our producLs aL any Llme wlLhouL noLlce. lor acLual producL lnformaLlon and recommendaLlons, please conLacL your local Malema represenLaLlve.