ADROIT" HAS BEEN EXECUTED SUPPLIED AND INSTALLED THE FOLLOWING ORGANISATIONS: AA00 STEEL PLANT AA01. Installation, testing and commissioning of 2 Nos. 1.6MVA 6000 / 415 Volts Transformer. Motor operated HT / LT Switchgear panel, 3000Amps LT Bus-Trunking form LT Switchgear to Transformer, Laying of Approximately 3 KM
ADROIT" HAS BEEN EXECUTED SUPPLIED AND INSTALLED THE FOLLOWING ORGANISATIONS: AA00 STEEL PLANT AA01. Installation, testing and commissioning of 2 Nos. 1.6MVA 6000 / 415 Volts Transformer. Motor operated HT / LT Switchgear panel, 3000Amps LT Bus-Trunking form LT Switchgear to Transformer, Laying of Approximately 3 KM
ADROIT" HAS BEEN EXECUTED SUPPLIED AND INSTALLED THE FOLLOWING ORGANISATIONS: AA00 STEEL PLANT AA01. Installation, testing and commissioning of 2 Nos. 1.6MVA 6000 / 415 Volts Transformer. Motor operated HT / LT Switchgear panel, 3000Amps LT Bus-Trunking form LT Switchgear to Transformer, Laying of Approximately 3 KM
AA00 STEEL PLANT AA01. Installation, testing and commissioning of 2 Nos. 1.6MVA 6000/415 Volts Transformer. Motor operated HT/LT Switchgear panel, 3000Amps LT Bus-Trunking form LT switchgear to Transformer, Laying of Approximately 3 KM HT/LT Cable through tunnel with associated jointing and earthing of the entire sub-station, ventility equipment and illumination of the sub-station for medium pressure boiler sub-station at ROURKELA STEEL PLANT ROURKELA OF ORISSA. AA.02. Installation testing commissioning of 7-panel 3.3.KV switchgear Crompton make coupled with Reyrolle England make switchgear with the compound filled busbar with Metering and Annunciator Panel HT and LT cable laying with associated jointing and earthing at 3.3KV indoor Substations for INDIAN IRON & STEEL CO. LTD KULTI BURDWAN OF WEST BENGAL. AA03. Installation testing and commissioning of 33/11KV 7.5MVA Transformer Feeding to the Arc Furnish Transformer 33KV/415Volts 500KVA Transformer, 33KV MOCBs 33KV Isolators CTs, PTs Lighting Arrestors Tubular/ACSR Bus bar system steel structure etc at outdoor substation for BIHAR FOUNDARY & CASTING LTD, RAMGAH RANCHI OF BIHAR. AA04. Installation testing and commissioning of 33/11KV 7.5MVA Transformer, 33KV/415Volts 500KVA Transformer 33KV MOCBs 33KV Isolators CTs PTs, Lighting arriestors Tubular/ACSR bus-bar system, steel structure at outdoor substation of PURULIA STEEL LIMITED PURILIA OF WEST BENGAL. AA05. Installation Testing Commissioning of 33KV/11KV Outdoor substation for 2x2.5MVA Distribution Transformer complete structure work for High/Low Level Bus, gantrys, swing Bus, MOCB, Isolator, Lighting Arrestor, CTs, PTs and the entire overhead connection by ACSR Conductor in between the equipment, Breaker /Relay control panel, Battery/ Battery charger Earthing and control cabling work for BIHAR STATE ELECTRICITY BOARD FOR LOHARDANGA RANCHI OF BIHAR. AA06. Installation Testing Commissioning OF 11kv Indoor substation for 1000KVA Transformer Switchgar, Cabling Earthing work for MELCAST INDIA LIMITED DURGAPUR BURDWAN OF WEST BENGAL AA07. Installation Testing Commissioning Of 33kv Outdoor substation 2x2MVA 33KV/415Volts outdoor transformer complete structural work for MOCB, Isolator, CTs,PTs, Lighting Arrestor Breaker, Relay Control Panel Overhead interconnection by ACSR conductor, Battery/Battery charger & control cable laying jointing entire earthing work at USHA MARTIN BLACK LIMITED WIRE&ROPE DEPT. TATILSAWARI, RANCHI BIHAR. AA08. Installation testing Commissioning of 3MVA 33KV indoor type Transformer laying and jointing of 33KV grade XLPE cable from 33KV outdoor switchyard through isolator with fuses control cables and allied earthling work developing of 33KV High level tubular bus bars additional to the existing 33kv low- level bus bars.Installation of 5000Amps LT Bus duct for the Cable terminations for USHA MARTING INDUSTRIES LIMITED ADITYAPUR JAMSHEDPUR BIHAR. BBOO PAPER MILLS BB 01 Supply and installation testing and commissioning of 3200 Amps LT Distribution Board 3200A Bus Trnking 5 KM 3.5 core 400 sq. mm PVC&A cable laying with associated jointing Battery charging Panels ladder type cable tray for complete renovation of power distribution system including 2 set of 800KVAR and 900KVAR Capacitor Bank with allied Automatic Power Factor Correction Relay and Control Panel with allied cabling and earthing etc for INDIA PAPER PULP MANAGEMENT OF WEST BENGAL INDUSTRIAL DEVELOPMENT CORPORATION LTD HAZINAGAR 24 PARGANAS OF WEST BENGAL.
BB02 Installation testing and commissioning of 132KV Switchyard involving 2 Nos. 7.5MVA 132/33KV Transformer 2 neutral grounding resistors 3 Nos 132KV M.O.C.B 9 Nos Lighting Arriestors Duplex Relay and Control Panel Battery and Battery Charger Earthing work laying and jointing of control cable for HINDUSTAN PAPER CORPORATIOIN LTD JAGI ROAD NOWGONG OF ASSAM.
BBO3. Supply Installation testing and commissioning of 1000KVA Alternator Control Panel with obtaining of protection Annunciator Metering in all respect with Synchronizing arrangement at UNIVERSAL PAPERS MILLS LTD, JHARGRAM, MIDNAPUR, WEST BENGAL. CC00 OTHER INDUSTRIAL UNITS. CC01. Installation testing and commissioning of 500KVA 6.6kv Indoor Transformer with Automatic Voltage Regulator, 300Amps Rectifier Drawing the DC Bus-bar 50Mtr to cell and associated HT/LT cabling Jointing & Earthing work etc. for SWAIKA VANSPATI PRODUCTS LTD LILUAH HOWRAH WEST BENGAL. CC02. Installation testing and commissioning of Indoor/outdoor 300KVA up to 600KVA Transformer and allied HT& LT Switchgear Motor Motor Starter generating set complete HT/LT cabling earthing lighting works for Potato Cold Storage number of about 18-20 COLD STORAGE AT HOOGHLY, BURDWAN BANKURA AND MIDNAPUR DISTRICT OF WEST BENGAL. CC03. Installation testing and commissioning of 2X 1250 KVA 6.6KV/415 Volts Indoor Transformer and 200Amps HT Oil fuse switch and 3 Nos. of XLPE cable and 500 mtr 3.5 core x300sq.mm LT Cable laying in trench/tray and earthing works and supply of 2 Nos 2500Amps Main LT Distribution Board 1 No. 2000Amps 6Mtr. Long LT Bus-Duct Rising Main coupled with 1250KVA Transformer Terminal taken up to 8th floor for load distribution at APEEJAY HOUSE 15PARK STREET, CALCUTTA OF WEST BENGAL. CC04. Installation testing and commissioning of 4 Nos Sub-stations out of four 3 Nos. substations each 2x 1000KVA 11KV 433Volts Indoor Transformer with 3 Nos. Panel HT switchgear and other one Main Sub-Station 11Nos Panel HT switchgear Battery/Battery charger and HT 11IV PILCDSTA cable laying length of 2 KM with crossing of yeard Rail line High drain Road for 3 Nos. substation of the plant. Carried out of high Bay Light fitting of 500 Nos. 400Wats Mercury Vapor light fitted at about 80FT height shed with drawn 6000 mtr conduit line for their entire factory lighting for above project at MARINE DIESEL ENGINE PROJECT, DURAH RANCHI BIHAR A/C; GARDEN REACH SHIP BUILDERS & ENGINEERS PVT LTD CALCUTTA OF WEST BENGAL(UNDER THE MINISTERY OF DEFENCE) GOVT. OF INDIA. CC05. Installation testing and commissioning of 250 kva 11kv/415Volts Indoor Transformer 11KV Oil fuse switch Board HT < Cable & Earthing works for INDIAN OIL CORPORATION RAXOUL LPG BOTTLING PLANT CC06. Installation testing and commissioning of.2 SET 1600 Amps LT Bus Duct coupled with both end with SIEMENS make switchgear and 1000KVA Transformer end with ballo expansion joint at their INTEK SUB-STATION AT KOLAGHAT THERMAL POWER STATION MECHEDA MIDNAPUR OF WEST BENGAL. CC07. Design supply Installation testing and commissioning of LT Bus-duct having rated continuous current 2500Amps complete with Busbars enclosures accessories supports service bridge etc. for connecting DG supply to main LT Panel (PCC) through 2500A ACB incomer module. 100MTR 3.5corex300Sq. mm 110V grade LT Power cable for connecting DG sets with power panel . The work includes laying terminations and jointing of power cables in excavated trench and cable trays including provided cable trays clamp etc. At:MOTHER DAIRY DANKUNI, HOOGHLY WEST BENGAL UNDER NATIONAL DAIRY DEVELOPMENT BOARD SALT LAKE CITY, KOLKATA. CC08. Design supply Installation testing and commissioning of LT Bus-duct with copper bus bar having rated continuous current 4000Amps for connecting to 3000KVA Furnace Transformer through 4000Amps ACB Incomer. AT C.P.RE-ROLLERS PVT. LTD DURGAPUR WEST BENGAL. CONSULTANT DECSON LTD. CC09. Design manufacturing installation testing and commissioning of extension panels at unit substations No.III& IV and MCC No.5,6&8 in Dankuni Coal Complex Plant at DANKUNI, HOOGHLY WEST BENGAL SUBSIDIARY OF COAL OF INDIA LIMITED DD00. 2 Nos PUMP HOUSE (WATER TREATMENT PLANT) EACH UNIT Supply and Installation testing and commissioning of 3200Amps LT Distribution Board for 2x 350 KW sleering Motor Pump complete with Starter and allied cabling earthing work complete with testing and commissioning for PUMP HOUSE STATION AT MOKOKCHUNG OF NAGALAND. EE00. TEA GARDEN Making of complete layout plan installation and commissioning of entire Tea Factory job involved installation of 2x500KVA 11/415KV Transformer at outdoor switchyeard with LT Power Receiving Feeder Piller & Main Power Distribution Board sub-distribution for Trough House. Processing Room Drying Room Storing Room Machine Shop with miscellaneous loads for the standby supply installation of D.G. Sets having equivalent capacity and necessary change over panel for changed of load distribution complete cabling and earthing for the entire job their six Tea Garden of Bengal Tea Industries Limited,, KOTALGOORIE TEA ESTATE of Assam Tea Company & OTHERS TEA GARDEN OF ASSAM. HOTEL Installation and Commissioning of 1500KVA,6000 /415Volts indoor dry type Transformer and Switchgear complete HT< cabling and earthing work as per IS/BS standard with maintaining the safety factor for Temperature rise with the proper protection at THE PARK HOTEL(5 Star) at Park Street, Kolkata, India. Supply , Installation and Commissioning of entire LT Switch Board HOTEL ANNAPURNA at Kathmandu, Nepal. Supply, Installation and Commissioning of 500KVA Alternator Control and the Load Distribution System of their existing Grid supply complete interlocking , earthing of the DG panel at MAURJA SERATON HOTEL PATNA BIHAR Supply, Installation and Commissioning 4000Amps LT BUS-DUCT for their 2500KVA Transformer and 4000Amps LT Switchgear Total 95 MTR for their 10 set of Transformer at Urinium Corporation of India Limited of Turandh Mill Jamshedpur, Jharkahand, India under the ATOMIC ENERGY COMMISSION(Ministry of the Defense) Design supply Installation testing and commissioning of 2000A 11KV 3 Phase Bus-duct with copper bus bar for inter connection in between front and back row of 2000A 11 KV VCB Panels. for Durgapur Project Limited at theor A - Zone Substation consultant Descon Limited. FF02 Installation, testing and commissioning the 31.5 MVA, 132/11KV Transformer with complete allied work of transforting, loading and unloading from B-Zone sub Station to C-Zone Sub Station of DPL, Durgapur, West Bengal.On behalf on Descon Ltd FF03 Installation, testing and commissioning the 31.5 MVA, 132/11 KV, 5th Transformer bay switch yard adjoining of existing transformer bays at B-Zone Sub Station Of DPL. Complete Job involving the allied equipment (132 and 11 KV switchgear equipment), structure, high level and low level Bus bar (ACSR moose conductor, panther etc.), complete control and power cabling and earthing work at B-Zone Sub Station of DPL, Durgapur, A/c, Durgapur Project Ltd on behalf of Descon Ltd, Kolkata.