Dual-frequency network optimization equipment due to the introduction of Xing macro

and micro switch for 900M and 1800M stratified, general terms, 900 1800M macro micro
switch for the upper to the lower, MS, 900 900 and 1800
1800 Switching between layers are of the same, MS were PBGT switched, 1800 900 for
lower switching to the upper, MS downlink level switching. For continuous coverage of
urban 1800M base, stratification will bring good coverage and excellent call quality,
and for the 1800M discrete base stations covering suburban or rural county, 1800
900 due to lack of coverage, the downstream level switch easily lead dropped calls. 1.1
1800M discrete optimization strategies base covered: 1 by adjusting the parameters to
influence the C1, C2algorithm: City 1800M site more area can be 1800M of CRO (re-
election bias) adjusted 4-5,900M the CRO adjusted to 0. By adjusting the influence CRO
C2 algorithms. For some serious imbalance of urban traffic, without affecting the
coverage of the premise can 900M of PWR (transmit power) appropriately reduced,
while the site of the city's 900 and 1800M minimum access level can be adjusted
to 15 affect C1 algorithms. 2 by adjusting engineering parameters to control
coverage: 900M site can be covered through the regulation of the cell under the
inclination to shrink, so1800M 900M shrinking coverage area, further
sharing 900M traffic. 3 traffic through the switch be shared: points four different
scenarios were set as follows: , 900 residential district cut 1800: 900 1800 for
the upper to the lower switch, namely macro-micro switch, PBGT switching threshold
default, the macro micro switch point switching threshold raised to 30 (-80dBm),
cut 900commutation control macro micro switch start threshold to keep the default,
(continuous coverage area can be properly adjusted, the maximum 63). Macro and
micro switch principle: When 900Mlevel meets the macro and micro switch start
threshold, while the 1800M level meet-point switch in macro and micro switching
threshold, MS startup macro micro switch, then the comparison
threshold, 1800M stronger than 900M level 27 (3dB) when, MS from 900M tangential
1800M. , 1800 district cut 900 district: 1800M district are open
different frequency PBGT, which point to point inPBGT switched minimum
threshold (HoMarginPbgt) unified set 32, the intensity switch minimum
threshold (HoMarginRxLev) unified set of 30 quality switched minimum threshold (
HoMarginRxQual) unified set of 30, the minimum
reception strength grades (RxLevMin) unified set to 15,
MS maximum power level (MsTxPwrMax) unified set to 5; goal is to try to keep the phone
on 1800 network calls. , 1800 1800 cut residential
district: MS maximum power level (MsTxPwrMax) unified set to 0,
all items other parameters set by default. , 900 residential district cut 900: system
default parameter settings for each item.
Specific parameters adjusted in the following table: Type parameter values recommended
multi-band cell function parameter list indicates (MulbandReport) 3 early class standard
transmission control (ECSC) 1 cell access parameters allows access to the minimum
reception level (RxLevAccessMin) dense urban stations , 900 can be set to 15,1800 set
to 10 cell reselection parameter tablereselection parameter indicates (CellReselPI) 1 re-
election bias (ReselOffset, 2db) Recommendation 1800 District 3-5, 900-cell is zero penalty
time (PenaltyTime , 20s) 0 or 31 adjacent cell handover and re-electing
table MS maximum power level (MsTxPwrMax) 900 is set to 5, 1800 is set to 0 minimum
receiving intensity level (RxLevMin) 15 PBGT switched minimum threshold (HoMarginPbgt) 1800-
> 900 is set to32, the other is the default, which are open 1800M cell switching-
frequency PBGT intensity minimum threshold (HoMarginRxLev) 1800 900 is set to 29-31, the
other to switch the default minimum quality threshold (HoMarginRxQual) 1800-> 900 is set
to 28 -30, the other for the default macro - micro-switch threshold (MacroMicroHoThs) 900
1800 set 31-40,1800 900 default macro - micro-switchthreshold
counter (MacroMicroHon) set 2-3, Set 3 slow switching can reduce levels of the adjacent
cell (NCellLayer) recommended the same frequency is set
to a room, different frequency 900-> 1800 set to3 different frequency 1800-> 900 is set
to a cut in exchange for a cell-like parameter table macro - micro switch start
threshold (MacroMicroStartThs) 900 district-level macro-micro-switch start threshold is
set to 55-60 (up to 47, it is recommended to between 55-
60) switching cell switching control parameter table type (HoControl)
900 cell as 3,678,224 1800 6,815,760 residential community set among the shortest
switching interval (HoMinInterval, s) 900 and 1800 are set
to 5 standard PBGT district switched applicable level (PbgtHoLayer) 900 and 1800 are set
to 9
Optimization Strategies 1.2 1800M base continuous coverage: Impact C1 and C2 algorithm as
2.1 1,2 practice the same, in addition to switching and discontinuous coverage area is
slightly different:points four different scenarios were set as follows:
, 900 residential district cut 1800: 900 1800 for the upper to the lower switch,
namely macro-micro switch, PBGT switching threshold to the default, point to switch
the macro and micro switch door limit raised to 35 (-75dBm), cut 900 of the switching
control macro micro switch start threshold raised to 50 (maximum 63). Macro and
micro switch principle: When 900M level meets the macro and micro switch start
threshold, while the 1800M level meet-point switch in macro and micro switching
threshold, MS startup macro micro switch, then the comparison
threshold, 1800M stronger than 900M level 27 (3dB) when, MS from 900M tangential
1800M. , 1800 cell 900 cut cell: 1800 900 level shift the downlink, due to the
realization of continuous coverage, 1800M downlink acceptable strength can be set
to 30 (-80dBm), when the MS power level reaches -83dBm, downlink start level switch,
then the switching point according to the comparison threshold. , 1800 1800 cut
residential district: MS maximum power level (MsTxPwrMax) unified set to 0,
all items other parameters set by default. , 900 residential district cut 900: system
default parameter settings for each item. Specific parameters adjusted in the following
table:
Type parameter values recommended multi-band cell function parameter
list indicates (MulbandReport) 3 early class standard transmission control (ECSC) 1 cell
access parameters allows access to a minimum reception level (RxLevAccessMin) dense
urban station, 900 can be set to 15 1800 is set to 10 cell reselection parameter
table reselection parameter indicates (CellReselPI) 1 re-election bias(ReselOffset,
2db) Recommendation 1800 District 3-5, 900-cell is zero penalty time (PenaltyTime, 20s)
0 or 31 adjacent cell handover and re-electing table MS maximum power level (MsTxPwrMax)
900 is set to5, 1800 is set to 0 minimum receiving intensity level (RxLevMin) 15
PBGT switched minimum threshold (HoMarginPbgt) 1800-> 900 is set to 32, the other for By
default, which are open 1800M cell switching-frequency PBGT intensity minimum
threshold (HoMarginRxLev) 1800 900 is set to 27, the other default
Switching minimum quality threshold (HoMarginRxQual) 1800-> 900 is set to 26, the
other default macro - micro-switch threshold (MacroMicroHoThs) 900 1800 set 31-40,1800
900 default macro - micro-switch threshold counter (MacroMicroHon) set 2-
3, mitigation can switch to three neighboring district level (NCellLayer) recommended the
same frequency is set to a room, different frequency 900-> 1800is set to 3, 1800->
900 set two district cut in exchange for sample parameter table macro - micro-
switch start threshold (MacroMicroStartThs) 900 district-level macro-micro-switch start
threshold is set to 55-60 (up to 47, it is recommended to between 55-
60 of) cell switch parameter table cut change control type (HoControl)
900 cell to 3,678,224 in 1800 to between 7,864,336 cell-cell handover shortest
interval (HoMinInterval, s) 900 and 1800 are 5 standard PBGT switched applicable
level (PbgtHoLayer) 900 to 9, 1800 Make four downlink reception strength (HoDlLevThs)
1800 Community set 27-30 (with macro and micro switch threshold difference
of 6dB above), 900 residential default uplink reception quality (HoUlQualThs)
1800 to 41,900 residential default downlink reception quality (HoDlQualThs)
1800 plot to 35,900 switching the default value of N Pbgt
1800 to 4,900 residential default Pbgt switching P value 1800 to 3,900 residential default