Vous êtes sur la page 1sur 6

TECHNICAL DATA SHEET FOR 1.

1 KV AI, XLPE INSULATED ARMOURED CABLES


Client: Jackson Engineers Limited
-2386140032 Dated: 17.09.2014
Rev:01 Dated: 24.09.2014
S.No. Description Units 2C x 185
1.
2C x 240
1
2
3
4
5
6
7
8
GENERAL
Name of Manufacturer
Voltage Grade
Standards Applicable
Type of curing
CONDUCTOR
Material
Nominal Cross Sectional Area
Shape of conductor
Nominal Diameter
No. of Wire (approx)
Nominal Diameter of each strand (before
stranding)
Max. DC Resistance at 20 C
Approx. AC Resistance at 90 C
Short Circuit Current for 1 sec
Approx Reactance at 50 Hz
Approx Capacitance at 50 Hz
CONDUCTOR TEMPERATURE (Max.)
Rated
During short circuit
INSULATION
Material
Thickness (Nominal)
Tolerance on thickness (-ive)
CORE COLOUR
INNER SHEATH
Material
Thickness (Minimum)
Colour
ARMOUR
Material
Nominal dimensions of armour
Type
Armour Fault level with stand capacity with its
duration
OUTER SHEATH
Material
Thickness (Minimum)
Colour
kV
Sq.mm.
Nos.
mm
Ohms/Km
Ohms/Km
kA/sec
Ohms/Km
uF/km
Deg C
Deg C
mm
mm
mm
mm
kA/Sec.
mm
M/s KEI Industries Limited
1.1 kV
IS: 7098 (P-1)
Sioplas
Aluminium of H2 Grade as per Class-2 of IS: 8130
185 240
Stranded Compacted Sector Shaped
Not applicable Setor Shaped
37 37

2.58 2.98

0.164 0.125

0.210 0.160

17.4 22.6

0.072 0.072

0.29 0.31
90 C
250 C
Extruded XLPE as per IS: 7098 (P-1)
1.6 1.7
0.1+0.1*t (where t = nominal thickness of insulation)
For 2 Cores Red & Black colour
Extruded PVC "Type ST-2" as per IS: 5831
0.5 0.5
Black
Galvanised Steel Flat Strip armoured as per IS: 3975
4 x 0.8 4 x 0.8
Strip Strip
2.63 2.85
Extruded PVC "Type ST-2" as per IS: 5831
1.72 1.88
Black
z-Th
TECHNICAL DATA SHEET FOR 1.1 KV Al. XLPE INSULATED ARMOURED CABLES
Client: Jackson Engineers Limited

,Fic4EAr
- 17.09.2014

Rev:01 Dated: 24.09.2014


S.No. Description Units 2C x 185
1
2C x 240
9
10
10
11
12
CABLE DATA
Approximate Overall dia of cable
Tolerance on Overall dia
Approx weight of cable
Continuous current rating for
different cables when laid up
In Ground @ 30 Deg.0
In Air @ 40 Deg.0
Drum Details
Packing Length
Individual Drum Tolerance
Overall Quantity Tolerence
Sequential length marking
Embossing
mm
mm
Kg./Km
Amps.
Amps.
meters
%
%
37.1 40.2
2.0 mm 2.0 mm
2100 2550
356 407
420 497
In non returnable Wooden Drum as per IS: 10418
13 x 1000
I
1 x 1100 + 1 x 1000
5%
5%
Shall be provided on outer sheath at every one mtr
KEI-Cable Electric 1.1 kV, Cable Size, Year of Mfr.
1
TECHNICAL DATA SHEET FOR 33kV WO AL XLPE INSULATED ARMOURED CABLE
Client: Jackson Engineers Limited
P.O.NO: ZNB-2386140032 Dated: 17.09,2014

Rev: 01 Dated: 24.09.2014


S.No. Description Units 3C x 240
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
GENERAL
Name of Manufacture
Voltage Grade
Standards Applicable
Curing method
Extrusion method
CONDUCTOR
Material
Nominal Cross Sectional Area
Shape of conductor
Nominal Diameter
No of Wire (approx)
Nom. Diameter of each wire (before
stranding)
Max. DC Resistance at 20 Deg.0
Approx. AC Resistance at 90 Deg.0
Short Circuit Current for 1 sec
Approx Reactance at 50 Hz
Approx Capacitance at 50 Hz
Max CONDUCTOR TEMPERATURE
Rated
During Short Circuit
CONDUCTOR SCREEN
Material
Thickness (Minimum)
INSULATION
Material
Thickness (Nominal)
INSULATION SCREEN
Material
Thickness (Minimum)
METALLIC SHIELD
Material & Thickness
Earth Fault Current Capacity
CORE COLOUR
INNER SHEATH
Material
Thickness (Minimum)
Colour
ARMOUR
Material
Size of armour (Nominal)
Type
Armour Fault level with stand capacity with
its duration
kV
Sq.mm.
mm
Nos.
mm
Ohms/km
Ohms/km
kA/sec
Ohms/km
uF/km
Deg C
Deg C
mm
mm
mm
mm
mm (W x T)
kA/Sec.
M/s KEI Industries limited
33kV (UE)
Generally as per IS: 7098 (P-2)
Dry Curing
Triple
Aluminium of H2 Grade as per Class-2 of IS: 8130
240
Stranded Compacted Circular
18.5
37
2.98
0.125
0.160
22.6
0.106
0.20
90 C
250 C
Extruded Semi Conducting Compound
0.3
Extruded XLPE as per IS: 7098 (P-2)
10.0
Extruded Semi Conducting Compound
0.3
Copper tape of 0.04 mm (Approx) thickness with Approx 10% Overlap
300 A for 1 sec (Collectively for 3 Cores)
For 3 cores- Coloured Strips of Red, Yellow & Blue
Extruded PVC "Type ST- 2" as per IS: 5831
0.7
Black
Galvanised Steel Flat Strip as per IS: 3975
4 x 0.8
Strip
8.6
..,----,_. ..0<!-- A4r68
TECHNICAL DATA SHEET FOR 33kV (UE) AL XLPE INSULATED ARMOURED CABLE
Client: Jackson Engineers Limited
ZNB_

Rev: 01 Dated: 24.09.2014


S.No.
-
Description Units 3C x 240
11.0
12.0
13.0
14.0
15.0
16.0
OUTER SHEATH
Material
Thickness (Minimum)
Colour
CABLE DATA
Approximate overall dia of cable
Tolerance on overall dia
Approx weight of cable
Continuous current rating for
different cables when laid up
In Ground @ 30 Deg.0
In Air @ 40 Deg.0
Drum Details
Packing Length
Individual Drum Tolerence
Overall Quantity Tolerence
Sequential length marking
Embossing
mm
mm
mm
Kg./Km
Amps.
Amps.
Mtrs
%
%
Extruded PVC "Type ST-2" as per IS: 5831
3.0
Black
97.7
3 mm
10000
310
400
In non returnable Wooden Drum as per IS: 10418
9x 250 +lx 150
5%
5%
Shall be provided on outer sheath at every one mtr
KEI-Cable Electric 33 kV (UE), Cable Size, Year of Mfr.
....0.71IM ...
TECHNICAL DATA SHEET FOR 1.1 kV AL XLPE INSULATED ARMOURED CABLES
Client: Jackson Engineers Limited
- 17.09.2014

Rev: 01 Dated: 24.09.2014


S.No. Description Units 3.5C x 70
1.0
2.0
3.0
4.0
5.0
6.0
7.0
GENERAL
Name of Manufacturer
Voltage Grade
Standards Applicable
Type of curing
CONDUCTOR
Material
Nominal Cross Sectional Area - Main
Nominal cross sectional Area - Neutral
Shape of conductor
No of Wire/(approx) (Main/Neutral)
Nominal Diameter of each strand (Before
stranding) (Main/Neutral)
Nominal Diameter (Main/Neutral)
Max. DC Resistance at 20 C - Main
Max DC Resistance at 20C - Neutral
Approx. AC Resistance at 90 C - Main
Approx. AC Resistance at 90C - Neutral
Short Circuit Current for 1 sec. - Main
Approx Reactance at 50 Hz
Approx Capacitance at 50 Hz
Max CONDUCTOR TEMPERATURE
Rated
During short circuit
INSULATION
Material
Thickness (Nominal) - Main
Thickness (Nominal) - Neutral
Tolerance on thickness (-ive)
CORE COLOUR
INNER SHEATH
Material
Thickness (Minimum)
Colour
ARMOUR
Material
Nominal dimensions of armour
Type
Armour Fault Level with stand capacity with its
duartion
kV
Sq.mm.
Sq.mm.
Nos.
mm
mm
Ohms/Km
Ohms/Km
Ohms/Km
Ohms/Km
kA/sec
Ohms/Km
uF/km
Deg C
Deg C
mm
mm
mm
mm
mm
kA/Sec.
M/s KEI Industries Limited
1.1 kV
IS: 7098 (P-1)
Sioplas
Aluminium of H2 Grade as per Class-2 of IS : 8130
70
35
Stranded Compacetd Sector Shaped
19/7
2.20/2.58
Not applicable for Sector Shaped
0.443
0.868
0.567
1.111
6.6
0.077
0.26
90
o
C
250 C
Extruded XLPE as per IS: 7098 (P-1)
1.1
0.9
0.1+0.1*t, (where t = nominal thickness of insulation)
For 3.5 Cores- Red, Yellow, Blue & Black Colour.
Extruded PVC "Type ST-2" as per IS: 5831
0.4
Black
Galvanised Steel Flat Strip as per IS: 3975
4 x 0.8
Strip
2.56
/\
TECHNICAL DATA SHEET FOR 1.1 kV AL, XLPE INSULATED ARMOURED CABLES
Client: Jackson Engineers Limited
P.O.NO: ZNB-2386140032 Dated: 17.09.2014

Rev: 01 Dated: 24.09.2014


S.No. Description Units 3.5C x 70
8.0
9.0
10.0
11.0
12.0
13.0
OUTER SHEATH
Material
Thickness (Minimum)
Colour
CABLE DATA
Approximate overall dia of cable
Tolerance on overall dia
Approx weight of cable
Continuous current rating for
different cables when laid up
In Ground @ 30 Deg.0
In Air @ 40 Deg.0
Drum Details
Packing Length ,
Individual Drum Tolerance
Overall Quantity Tolerence
Sequential length marking
Embossing
mm
mm
mm
Kg./Km
Amps.
Amps.
Mtrs
%
%
Extruded PVC "Type ST-2" as per IS: 5831
1.56
Black
31.6
2.0 mm
1500
167
176
In non returnable Wooden Drum as per IS: 10418
1 x 1100 + 1 x 1000
5%
5%
Shall be provided on outer sheath at every one mtr
KEI-Cable Electric 1.1 kV, Cable Size, Year of Mfr.,

Vous aimerez peut-être aussi