Vous êtes sur la page 1sur 2

Phase Filter LTE800/UMTS900/GSM900

FP-A08E15-OD01
Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

Issued: June.13
Control: 0-0-5
1/2



Technical Specifications
Electrical
Pass Band MHz
RX: 880 895/839.5 847/905-915
TX: 925 940/798.5 806
Ports Isolation
Port 1 to Port 2 (TX) dB 25
Port 3 to Port 4 (RX) dB 25
Insertion Losses
RX dB
0.5 (0.4 typical)@880-895MHz
0.5 (0.4 typical)@839.5-847MHz
0.7 (0.5 typical)@905-915MHz
TX dB
Coupling value 3.1
Insertion loss 1.2
Amplitude
Differences
Port 1 to Port 2 (RX) 10%@880-895MHz
Port 3 to Port 4 (TX) 10%
Phase Difference
Port1Port3(TX):Port1Port 4(TX)

5max@925-940MHz
5max@798.5-806MHz
Phase difference
Port2Port3(TX):Port2Port 4(TX)
1805max@925-940MHz
VSWR
Port 2 (TX)
1.25@925-940MHz
4@798.5-806MHz
Port 1 (TX)
1.25@925-940 MHz
1.25@798.5-806MHz
Port 3 (RX)
1.25@880-895MHz
1.25@839.5-847MHz
Port 4 (RX)
1.25@880-895MHz
1.25@905-915MHz
Power Handling Continuous W 150
Intermodulation Products dBc -150@2x43dBm
Impedance 50
Mechanical &Environmental
Dimension (LxWxH excluding mounting
brackets)
mm (in) 400x210x55 (15.7x8.3x2.2)
Weight(Approximate) kg (lb) 7 (15.4)
RF Connectors DIN 7/16 female
Mounting Kit Pole (clamps included for 70-110mm)
Operating Temperature Range
o
C -40 to +65
Operational Humidity % <100
Lightning Protection Comply with IEC 61000-4-5; 8kA, 8/20s
Environment Class IP66 (Indoor or Outdoor)














Features and Product Description

Used for creating opposite phases and same amplitudes to the DL signals from port 2 on the two ports of X pol ANTs and
creating same phases and amplitudes to the DL signals from port 1 on each port of X pol ANTs.
Port 1 (BTS) supports-Tx: 925-940/798.5-806MHz, Rx: 880-895/839.5-847MHz.
Port 2 (BTS) supports-Tx: 925-940MHz, Rx: 880-895/905-915MHz.
Port 3 (Ant1) supports-Tx: 925-940/798.5-806MHz, Rx: 880-895/839.5-847MHz.
Port 4 (Ant2) supports-Tx: 925-940/798.5-806MHz, Rx: 880-895/905-915MHz.
Long connectors allow ease of waterproofing.
High power handling and low loss maximizes system performance.
High isolation minimizes interference.
Package includes 2 RF jumper cables with equal electrical length and phase difference of 2 degree.
Phase Filter LTE800/UMTS900/GSM900
FP-A08E15-OD01
Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

Issued: June.13
Control: 0-0-5
2/2


Outline Drawing

Vous aimerez peut-être aussi