Vous êtes sur la page 1sur 12

------------------------------------------------------------------------------------------------------------------------ - 1 -

MAHIMTURA CONSULTANTS PVT. LTD. ,


3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

C/7330/2014/R3 DESIGN BASIS REPORT Date: 8
th
May 2014



PROJECT : INDIAN INSTITUTE OF MANAGEMENT CAMPUS
AT TIRUCHIRAPPALLI.


CLIENT : INDIAN INSTITUTE OF MANAGEMENT, TIRUCHIRAPPALLI

NIT TRICHY CAMPUS (POST), THANJ AVUR ROAD,
TIRUCHIRAPPALLI - 620 015 ,


DESIGN ARCHITECT : CHANDAVARKAR & THACKER CONSULTANTS
PVT. LTD. ( C&T),

7, PALACE CROSS ROAD , BANGALORE 560 020


1. INTRODUCTION AND PROJECT DESCRIPTION-

The Indian Institute of Management, Tiruchirappalli is an educational campus. This project
consists of following different units-

A) Academic Units

This unit consists of following different units
1) 250 seater seminar room - Gr. Flr +Terrace
2) 120 seater class room - Gr. Flr +1
st
+Terrace
3) 80 seater class room - Gr. Flr +1
st
+Terrace
4) 50 seater class room - Gr. Flr +1
st
+Terrace
5) Amphitheatre - Gr. Flr +Terrace
6) Faculty offices - Gr. Flr +1
st
+2
nd
+Terrace
7) Visitor/Faculty lounge - Gr. Flr +1
st
+2
nd
+Terrace
8) Multipurpose rooms etc. - Gr. Flr +1
st
+Terrace
9) Connecting Corridor - Gr. Flr/1
st
Floor +Terrace
10) Arcade - Gr. Flr/1
st
Floor +Terrace


B) Residential Units

1) Students Hostel - Gr. Flr +1
st
to 3
rd
+Terrace
2) Married student hostel - Stilt +1
st
to 4
th
+Terrace
3) Staff Housing (Type A) - Gr. Flr.+1
st
to 3
rd
+Terrace
4) Staff Housing (Type A) - Gr. Flr.+1
st
to 3
rd
+Terrace
5) Faculty Housing - Gr. Flr +1
st
+Terrace
6) Directors Bungalow - Gr. Flr +1
st
+Terrace
7) Handicapped Housing - Gr. Flr +Terrace






------------------------------------------------------------------------------------------------------------------------ - 2 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI
C) Other units

1) Auditorium - Gr. Flr +1
st
+Terrace
2) Library - Basement +Gr. Flr +1
st
to 3
rd
+Terrace
3) Sports complex - Gr. Flr +Terrace
4) Dispensary - Gr. Flr +Terrace
5) Entrance gate - Gr. Flr +Terrace
6) Security Gate - Gr. Flr/1
st
Flr. +Terrace
7) Community market - Gr. Flr +Terrace
8) Estate office - Gr. Flr +1
st
+Terrace
9) Daycare - Gr. Flr +Terrace
10) Hostel Mess - Gr. Flr +Terrace
11) Canteen - Gr. Flr +Terrace
12) MDP ( Academic) - Gr. Flr +1
st
+Terrace
13) MDP ( Residential) - Gr. Flr +1
st
to 3
rd
+Terrace
14) Admin. - Gr. Flr +1
st
+2
nd
+Terrace (with connecting bridge)
15) Service units ( such as DG unit, Transformer, Water tanks, Sumps, Plant room etc.)
16) Elevated water tank /Beacon-

Foundation system for all structures to be open isolated foundation with soil bearing
capacities as follows (as per soil report dated 07.05.2014)
1) SBC value 15 T/sq.m at 1.5m below NGL for Academic Block , Faculty housing,
commercial complex, school , Estate office etc.
2) SBC value 30 T/sq.m at 2.5m below NGL for Auditorium, Admin Block, library,
Hostels, Mess hall, sports complex, non faculty apartments etc.
2. DESIGN LOADS

A) Super Imposed loads

The imposed loads that are envisaged to act permanently (wherever applicable) are
considered for analysis and design. These load values are based on IS: 875 (part-1)-1987
and general construction practice.
Imposed load intensities

Item Intensity in kN/m
2
of plan area
Floor Finish ( 20mm thk tiles with 20mmthk
cement mortar)
1.00
Weathering Proof Course 150mm thk
brickbat coba with IPS finish
3.00
False Ceiling with services 1.00
Light weight partition on floor 1.00
MEP Services 0.25
External Glazing 2.00
Toilet Sunk load ( consider 100 mm sunk) 2.00
Solar panel load 2.00
Roof sheeting 0.15
Polycarbonate sheet/ skylight 0.15

------------------------------------------------------------------------------------------------------------------------ - 3 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

B) Live Loads
The live load is assessed based on the occupancy classifications as per IS:875 (Part-2)-
1987 and are listed as below.
Name of Structure Occupancy Classification UDL (KN/m
2
)
Academic Units Class room & Lecture room 3.00
Academic Units
Seminar room /Auditorium/projector
room/ stage
5.00
Academic Units Store room/ server room 5.00
Academic Units Office, Reading room 4.00
Academic Units Stairs, corridors, passage 4.00
Academic Units
Stack room/stack area
(maximum height 2.2m)
6.00
Academic Units
Stack room/stack area
( maximum height 3.2m)
8.00
Academic Units Toilets & bath rooms 2.00
Academic Units
Sloping roof with slope less than 10
degree , access not provided except for
maintenance
0.75
Academic Units Flat Roof 1.50

Residential Units All rooms and kitchens 2.00
Residential Units Toilets & bath rooms 2.00


















------------------------------------------------------------------------------------------------------------------------ - 4 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

3. WIND LOADS

The wind pressure has been calculated based on the data furnished below and other
provisions laid in IS: 875 (Part 3)-1987
Basic Wind Speed V
b
= 47 m/sec
Risk Coefficient K1 = 1.04 (Probable Design life of structure is
assumed as 75 years)
Terrain Category = 3
Structure Class = Class B / C . as per individual unit
Factor K
2
= 0.82 to 1.00 .. as per individual unit
Topography factor K
3
= 1.0

Design Wind Speed and wind pressure can be calculated for individual units as per base
dimensions and height of structure with reference to IS: 875 (part 3)-1987.

AUDITORIUM BLOCK (SAMPLE CALCULATION)

For Preliminary analysis/design, the wind pressure has been calculated based on the data
furnished below and other provisions laid in IS: 875 (Part 3)-1987

Base dimension of the building along - L = 58m ; B =38.3m
Height of building (H) = 15.0m
Basic Wind Speed V
b
= 47 m/sec
Risk Coefficient K
1
= 1.04
Terrain Category = 3
Structure Class = Class C
Factor K
2
= 0.87
Topography factor K
3
= 1.0
DESIGN WIND SPEED (Vz) -

V
z
=V
b
.k
1
.k
2
.k
3

=47 x 1.04 x 0.87 x 1
=42.52 m/s

DESIGN WIND PRESSURE -

P
z
=0.6 x V
z
2

=0.6 x 42.52 x 42.52
=1084.77 N/sq. m

Force Co-efficient calculation-
Force Co-efficient (C
f
) in X direction = 1.20
Force Co-efficient (C
f
) in Y direction = 1.10

Considered C
f
=1.30 for ETAB analysis for both direction.

------------------------------------------------------------------------------------------------------------------------ - 5 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI
4. EARTHQUAKE LOAD


The loading due to earthquake is assessed based on the provisions of IS: 1893 (Part-
1):2002

Table-2 Zone factor (Z) = 0.16
Table-7 Response Reduction Factor (R) = 4.0
Table -1 Type of Soil = II
Height of building (H) = 25.0m (max.)

Table Showing Seismic Zone , Importance Factor and Ductile detailing applications for
individual building units -

Sr. No. Building Detail Seismic Zone
Importance
Factor
Ductile
Detailing as
per IS13920
1 Auditorium III 1.50 Yes
2 Library III 1.50 Yes
3 Administrative Block III 1.50 Yes
4 Academic unit III 1.50 Yes
5 MDP ( Academic) III 1.50 Yes
6 Sports complex III 1.00 No
7 Dispensary III 1.00 No
8 Entrance gate III 1.00 No
9 Community market III 1.00 No
10 Estate office III 1.00 No
11 Daycare III 1.00 No
12 Canteen III 1.00 No
13 MDP ( Residential) III 1.00 No
14 Students Hostel III 1.00 No
15 Married student hostel III 1.00 No
16 Staff Housing III 1.00 No
17 Faculty Housing III 1.00 No
18 Directors Bungalow III 1.00 No
19 Hostel Mess III 1.00 No
20 Handicapped Housing III 1.00 No

Fundamental Natural Period (T) is calculated for individual units as per base dimensions
and height of structure with reference to IS: 1893-2002.













------------------------------------------------------------------------------------------------------------------------ - 6 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

AUDITORIUM BLOCK (SAMPLE CALCULATION)

The loading due to earthquake is assessed based on the provisions of IS: 1893(Part-
1):2002

Seismic Zone = III

Table-2 Zone factor (Z) = 0.16

Table-6 Importance Factor (I) = 1.5

Table-7 Response Reduction Factor (R) = 3.0

Table -1 Type of Soil = II

Height of building (H) = 15.0m

Base dimension of the building along
Considered direction of lateral force (D) L = 58.0 m
B = 38.3 m
Fundamental Natural Time Period
T =0.075 H
0.75
from CL -7.61 IS 1893 (Part-1) 2002
=0.075 x (15)
0.75

=0.571 sec
Sa/g =2.381 from FIG-2 IS 1893 (Part-I) 2002
A
h
= Z . I . Sa
2 . R.g
= 0.16 x 1.5 x.2.381
2 x 3

= 0.0952


















------------------------------------------------------------------------------------------------------------------------ - 7 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI
5. BASIC LOADS AND LOAD COMBINATIONS


The various loads are combined in accordance with the stipulations in IS:875 (Part 5)-
1987. Wherever imposed load is combined with earthquake load the appropriate part of
the imposed load as specified in IS:1893-2002 is adopted both for evaluating earthquake
effect and for combined load effects, used in such combination.
Type Load Case LOAD COMBINATIONS
Primary 1 DEAD LOAD (DL)
Primary 2 WALL LOAD (WL)
Primary 3 SLAB DEAD LOAD (SDL)
Primary 4 LIVE LOAD (LL)
Primary 5 WIND LOAD X (+) WLX
Primary 6 WIND LOAD Z (+) WLZ
Primary 7 SIESMIC LOAD ALONG-X SLX
Primary 8 SIESMIC LOAD ALONG-Z SLZ
Combination 10 DL +WL +SDL +LL
Combination 11 DL +WL +SDL +LL +WLX
Combination 12 DL +WL +SDL +LL +WLZ
Combination 13 DL +WL +SDL +LL - WLX
Combination 14 DL +WL +SDL +LL - WLZ
Combination 15 DL +WL +SDL +LL +SLX
Combination 16 DL +WL +SDL +LL +SLZ
Combination 17 DL +WL +SDL +LL - SLX
Combination 18 DL +WL +SDL +LL - SLZ
Combination 19 DL +WL +SDL +WLX
Combination 20 DL +WL +SDL +WLZ
Combination 21 DL +WL +SDL - WLX
Combination 22 DL +WL +SDL - WLZ
Combination 23 DL +WL +SDL +SLX
Combination 24 DL +WL +SDL +SLZ
Combination 25 DL +WL +SDL - SLX
Combination 26 DL +WL +SDL - SLZ

6. LOAD FACTORS FOR DESIGN


Load Factor for Primary Load Cases Description of Load
Combination
Dead Load Live Load Wind Load Seismic
Load
Dead load +Live load 1.5 1.5 0.0 0.0
Dead load+Wind load 1.5 0 1.5 0.0
Dead load+Seismic load 1.5 0 0 1.5
Dead load+Live load+Wind load 1.2 1.2 1.2 0.0
Dead load+Live load +Seismic load 1.2 1.2 0 1.2
Dead load+Wind load 0.9 0 1.5 0.0
Dead load+Seismic load 0.9 0 0 1.5


------------------------------------------------------------------------------------------------------------------------ - 8 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI
7 ANALYSIS METHOD

The overall individual structure is analyzed for Static and Lateral loads due to
Earthquake/Wind loads and its combinations.
The analysis is conducted using standard software such as STAAD, Etabs and SAFE.

8. DESIGN ASSUMPTIONS

A) The design life of the structure is assumed as 50 years. This requirement is not
applicable to replaceable materials.
B) All R.C.C. structures will be designed according to the Limit State method as
specified in IS: 456-2000.
C) The R.C.C. structure is idealized as 3D space frame and analyzed using ETABS,
software for both vertical and lateral loads.
D) Forces and moments from the analysis output for the worst combinations are used for
the design of the structure.
E) Design of structural steel members as per IS: 800-1984
F) Expansion joint/strip to be provide at 45.0m (maximum) to control temperature effect.
G) Following buildings analyzed and designed with consideration of 1 typical floor
provision as per clients request
1) All Academic blocks,
2) Commercial complex,
3) Dispensary,
4) Faculty club,
5) Canteen,
6) Student Mess,
7) Estate Office.










------------------------------------------------------------------------------------------------------------------------ - 9 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

9. CONSTRUCTION DETAILS

1) All units except Auditorium, sports complex etc. have RCC floor slab with RCC beam
and slab system or flat slab system.
2) Auditorium, sports complex have m. s. sloping roof structure.
3) Library unit has few structural steel columns with infilled concrete for 15.0 m height.
4) Filling load = All filling in class room/seminar room considered as
light weight material filling. (i.e. light weight cinder)
5) Grade of Concrete = M30 For foundation/column/beams/slabs etc.
M40 For Post Tensioned beams
M25 For Grade slab
(Concrete design Mix as per IS 456-2000)
M15 (For P.C.C. )
6) Aggregate = 20mm and down size, mechanically crushed
aggregate
7) Reinforcements = Grade Fe500 as per IS 1786. (To be tested before use)
8) Cement = Grade 43
9) Minimum column width
Single / two storey building =230mm
More than two storey building =300 mm
10 ) Minimum beam width = 230 mm
11) Masonry work = Aercon AAC Block. (100mm/200mm thk.)
12) Expansion J oint = Provide Expansion joint for Acadamic unit, Admin
Unit, Type A, Type B, Married student hostel.
13) Temperature Analysis = Temperature analysis required for library unit.
( for 25
0
C temperature difference)
14) Structural steel = All the structural steel shall before fabrication
conform to IS:2062.( yield strength =250 N/sq. m.)
14) Electrode = Covered electrode shall conform to IS 814 or IS
1395 as appropriate. (Make of electrode to be
mention in tender document)
16) Welding = All welding connection as per IS 814,IS 1395,IS 819.



------------------------------------------------------------------------------------------------------------------------ - 10 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI

10. DEFLECTION LIMITS

The deflection limits under serviceability loads of a building or a building component
should be as per related IS codes (i.e. for RCC structure IS 456-2000 and steel structure
IS 800-2007).


11. CRACK WIDTH CONSIDERATION
(Reference - as per IS 456-2000 clause no. 35.3.2 )

Maximum surface crack width for all structures
except water/liquid retaining structures =0.3mm.
Water retaining structures =0.2 mm


12. MATERIAL

The self-weight of the various elements are computed based on the built weight of
materials as given below
(based on IS: 875 (part 1)-1987 and general construction practice)

Materials Unit Weight in kN/m
3

Steel 78.50
Plain Concrete 24
Reinforced Concrete 25
Soil 18
Water 10
Block 20
Brick 18
Light weight filling material
(light weight cinder)
8


13. REINFORCEMENT COVER -

The minimum clear cover to main reinforcement shall be as follows
(as per IS 456-2000.)-
Footings = bottom =75mm, sides =75mm,
Retaining wall = 40mm,
Raft Slab = 40mm,
Plinth beams = Bottom =50mm, sides =40mm
Floor beams = Bottom/side =40mm,
Floor slabs = 25mm.








------------------------------------------------------------------------------------------------------------------------ - 11 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI


14. FIRE RATING & EXPOSURE CONDITION -

Fire rating consideration
All external exposed structural members should design with consideration of 2 hours Fire
Rating and all internal members design for 1.5 hours Fire Rating.

Exposure Condition
All external exposed structural members should design with consideration of Moderate
exposure and all internal members design with Mild exposure condition.




15. FOUNDATION SYSTEM

Foundation system for all structures to be open isolated foundation with soil bearing
capacities as follows (as per soil report dated 07.05.2014)
3) SBC value 15 T/sq.m at 1.5m below NGL for Academic Block , Faculty housing,
commercial complex, school , Estate office etc.
4) SBC value 30 T/sq.m at 2.5m below NGL for Auditorium, Admin Block, library,
Hostels, Mess hall, sports complex, non faculty apartments etc.
















------------------------------------------------------------------------------------------------------------------------ - 12 -
MAHIMTURA CONSULTANTS PVT. LTD. ,
3
rd
floor , Unique House, S.A. Brelvi Road,
Fort, Mumbai -01.
PROJECT: INDIAN INSTITUTE OF MANAGEMENT
AT TIRUCHIRAPPALLI
16. CODES & STANDARDS

All analysis and designs are conforming to the relevant Indian Standards.
List of relevant Indian Standard codes refer for analysis & design-
CODE DESCRIPTION
IS:875 (Part-1)-1987 Code of Practice for Design Loads (Other than Earthquake)for
Building and Structures-Unit Weights of Buildings Materials and
Stored Material.
IS:875 (Part-2)-1987 Code of Practice for Design Loads (Other than Earthquake) for
Building and Structures-Imposed loads
IS:875 (Part-3)-1987 Code of Practice for Design Loads (Other than Earthquake) for
Buildings and Structures Wind Load.
IS:875 (Part-5)-1987 Code of Practice for Design Loads (Other than Earthquake ) for
Buildings and Structures - Special Loads and Load Combinations
IS:456 - 2000 Code of Practice for Plain and Reinforced Concrete
IS:2974 ( Part 1 to 5) Code of practice for Design and Construction of Machine
Foundation
IS:800 -1984 & 2007 Code of Practice for General Construction in Steel
IS:1893 (Part-1)-2002 Indian Standard Criteria for Earthquake Resistant Design of
Structures
IS:432 (Part-1)-1982 Specification of Mild Steel and Medium Tensile Steel bars and
Hard drawn Steel Wire for concrete reinforcement Mild Steel
and Medium Tensile Steel Bars
IS:432 (Part-2)-1982 Specification of Mild Steel and Medium Tensile Steel bars and
Hard drawn Steel Wire for concrete reinforcement Hard drawn
Steel Wire.
IS:1786-1985 Specification for High Strength Deformed Steel Bars and Wires
for Concrete Reinforcement
IS:1904 Indian Standard Code of practice for Design & Construction
foundations in Soil: General Requirements.
IS:1642-1989 Indian Standard Code of practice for Fire Safety Of Buildings
(General) : Details Of Construction.
IS:2062-1999 Specification of steel for General Structural Purposes
IS:3370 ( Part 1 to 4) Code of Practice for Concrete Structures for storage of Liquids
SP:6 Handbook for Structural Engineering