Vous êtes sur la page 1sur 2

malema.

com
Applicatons
WATER AND WASTE WATER PETROLEUM PRODUCTS
CONDENSATE, COOLING WATER ACIDS AND ALKALIES
& HOT WATER INDUSTRIAL GASES
COMPRESSED AIR
STEAM
Features
A novel design approach in fuid fow
measurement
High turn down: 10:1 typical; up to 50:1 for
some applicatons with multple transmit-
ters No need for straight runs
Stream lined measuring secton: Low pres-
sure drop
No moving parts
Measurement is independent of fow
regime:
Suitable for laminar, turbulent and transi-
ton fow conditons
High accuracy and repeatability
Volumetric and mass fow measurement
with built-in temperature sensor opton
Suitable for liquids, gases and steam
Patented design (Patent No. US 7,478,565 B2)
KFM 2100
MALEMA KINETIC
FLOW METER
Descripton
KFM 2100 Series is an advanced fow element that is suitable for liquid,
gas and steam fow measurement with high accuracy and repeatability.
Thanks to its patented design where a stream lined bullet shaped fow
element that causes a minimum disrupton to the fowing medium
providing unmatched fow turndown with very low pressure drop.
KFM 2100 series is available as a fow element separately as well as a
complete fow meter. In the frst opton, you have a choice of using a
diferental pressure transmiter of your preference. Alternatvely, we
can integrate the KFM fow element with a diferental pressure trans-
miter and supply as a fully calibrated unit.


KFM Primary Element
Patent No. US 7,478,565 B2
malema.com
General Specifcaton
Corporate Headquarters
1060 S Rogers Circle
Boca Roton, FL 33487
P: (561) 995-0595 F: (561) 995-0622
West Coast Headquarters
2225 Martn Avenue Suite I
Santa Clara, CA 95050
P: (408) 970-3419 F: (408) 970-3426
Asia Headquarters
29 Woodlands Industrial Park E1 Northtech Unit #
02-06 Singapore 757716
P: (65) 6482-3533 F: (65) 6484-4231
If you need a quote from us please visit our website: htp://malema.com/Industrial/pdf/Flow_Meter_Applica-
ton_Sheet.pdf , fll-in the details requested in the fow applicaton questonnaire and email/fax to us. We will
get back to you at the earliest.
Sizes to 3
End connecton Flanged, Screwed and Weld type
End connecton ratng ANSI #150, 300 & 600; other optons possible
Medium Liquids, gas (pending) and steam (pending)
Primary element accuracy +/- 0.5% of the rate
Repeatability +/- 0.1% of the rate
Materials: SS 316L Other optons on request
Versions
Primary Element
Primary Element with DP transmiter (volumetric fow)
Primary Element with mult-variable transmiter (mass fow)
Types In-line and inserton (pending)
Transmiter mountng Remote or integral (compact)
PRINCIPLE OF MEASUREMENT
An elongated fow-body of streamlined shape transforms the incident fuid fow in such a way that the sensors response is im-
mune to fow regime and variatons in fow velocity profle. Dynamic pressures, P1 and P2, are measured in proximity to the
streamlined fow-body. One pressure-sensing port faces upstream, the other downstream. The two signals are combined in
a unique way to simultaneously measure fuid volumetric fow rate, mass fow rate and density (for gases).
P1 = V2 + P0
P2 = - V2 + P0
P0 = statc pressure
V = average fow velocity
= gas density = (P1+P2)/ (2ZRT)
Mass fow Qm= K x (P x )
Where K = meter constant

Vous aimerez peut-être aussi