MURO

Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y20
Y21
X22

AREA

L
At1
At2
At3
At4
At5
At6
At7
At8
At9
At10
At11
At12
At13
At14
At15
At16

L(m)
2.80
2.97
1.86
2.00
1.85
3.85
2.00
2.3
1.3
2.04
1.32
2.04
1.76
1.73
1.87
0.59
1.94
1.75
1.85
2.70
1.80
2.70

0.3781
0.4455
0.6824
0.5008
0.2775
0.5143
0.4969
0.3450
0.1950
0.3061
0.3299
0.3061
0.2639
0.2594
0.2799
0.0763
0.2910
0.2625
0.2775
0.4054
0.2700
0.4050
7.5685

L
1.215
2.705
1.39
3.6
2.705
3.6
2.005
2.005
2.005
2.1
4.75
4.75
3.15
2.05
2.05
2.05
2.2875
2.2875

t(m)
0.150
0.150
0.150
0.250
0.150
0.150
0.250
0.150
0.150
0.150
0.250
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150

M2
1.6
1.6
1.6
1.215
3.6
1.39
1.215
2.705
1.39
1.125
2.705
2.705
1.39
1.215
1.39
1.215
2.705
2.705

1.944
4.328
2.224
4.374
9.738
5.004
2.436075
5.423525
2.78695
2.3625
6.424375
6.42
4.3785
2.49075
2.8495
2.49075
6.1876875
6.1876875

h(m)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Am(m2)
0.42
0.45
0.28
0.50
0.28
0.58
0.50
0.35
0.20
0.31
0.33
0.31
0.26
0.26
0.28
0.09
0.29
0.26
0.28
0.41
0.27
0.41

At17
At18
At19

2.1375
2.525
1.4

1.39
1.215
1.25

2.971125
3.067875
1.75
85.8393

MURO
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15

AREA
0.05
0.0695
0.06
0.0265
0.0412
0.045
0.225
0.1500
0.1350
0.0851
0.0899
0.045
0.21
0.3638
0.4163

L(m)
0.25
0.35
0.3
0.18
0.28
0.3
1.5
1
0.9
0.61
0.6
0.3
1.4
2.43
2.78

t(m)

h(m)
0.2
0.2
0.2
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Am(m2)
0.05
0.07
0.06
0.027
0.042
0.045
0.225
0.15
0.135
0.0915
0.09
0.045
0.21
0.3645
0.417

VERIFICACION DE LA DENSIDAD DE MUROS Y ESFUERZOS AXIALES

PROPIEDADES DE LOS MATERIALES


fc=
fy=
fm=
P.E.m=
P.E.c=

210
4200
50
1.8
2.4

kg/cm2
kg/cm2
kg/cm2
t/m3
t/m3

0.3
0.1

t/m2
t/m2

Aligerada H=0.20m
Contrapisos o Tabiqueria

0.25
0.1

t/m2
t/m2

Oficinas
Azotea

500
t/m2
Albaileria incluye el tarrajeo
Concreto

CARGAS
Muerta
Peso propio de la losa =
Acabados
Viva
Sobrecarga de Uso(tipico)=
Sobrecarga de Uso(azotea)=

ESPESOR MINIMO DE LOSMUROS


t=h/20
hm=
tm=

Zona Sismica
2.4
0.12

Viga Solera
Ancho=
Ancho=
Alto=

0.15
0.25
0.3

m
m
m

Muro
Y1
Y2
Y3
Y4
Y5

L(m)
2.80
2.97
1.86
2.00
1.85

Usar muros de Soga

Muros de Soga
Muros de Cabeza

ANALISIS DE LOS MUROS


DIRECCION Y

t(m)
0.15
0.15
0.15
0.25
0.25

h(m)
2.50
2.50
2.50
2.50
2.50

Am(m2)
0.42
0.45
0.28
0.50
0.46

Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y20
Y21
Y22

3.85
2.00
2.30
1.30
2.04
1.32
2.04
1.76
1.73
1.87
1.00
1.94
1.75
1.85
2.70
1.80
2.70

0.15
0.25
0.15
0.15
0.15
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50

0.58
0.50
0.35
0.20
0.31
0.33
0.31
0.26
0.26
0.28
0.15
0.29
0.26
0.28
0.41
0.27
0.41

Muro
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15

L(m)
1.50
1.00
1.00
2.00
2.00
1.00
1.50
1.00
1.50
2.00
2.00
1.00
1.40
2.43
2.78

t(m)
0.20
0.20
0.20
0.20
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

h(m)
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50

Am(m2)
0.30
0.20
0.20
0.40
0.30
0.15
0.23
0.15
0.23
0.30
0.30
0.15
0.21
0.36
0.42

DIRECCION X

Vol(m3)
1.05
1.11
0.70
1.25
1.16

Peso del
Muro(t)
1.89
2.00
1.26
2.25
2.08

CARGA MUERTA
Peso de la Peso de los Peso de la Viga
Area Tributaria
(m2)
Solera(t)
Losa (t)
Acabados(t)
1.94
0.49
0.19
0.30
4.33
1.08
0.43
0.32
2.22
0.56
0.22
0.20
4.37
1.09
0.44
0.22
9.74
2.43
0.97
0.20

CARGA VIVA
Peso de la Sobrecarga(t)
Tipico

0.486
1.082
0.556
1.0935
2.4345

1.44
1.25
0.86
0.49
0.77
0.83
0.77
0.66
0.65
0.70
0.38
0.73
0.66
0.69
1.01
0.68
1.01

Vol(m3)
0.75
0.50
0.50
1.00
0.75
0.38
0.56
0.38
0.56
0.75
0.75
0.38
0.53
0.91
1.04

2.60
2.25
1.55
0.88
1.38
1.49
1.38
1.19
1.17
1.26
0.68
1.31
1.18
1.25
1.82
1.22
1.82

Peso del
Muro(t)
1.35
0.90
0.90
1.80
1.35
0.68
1.01
0.68
1.01
1.35
1.35
0.68
0.95
1.64
1.88

5.00
2.44
5.42
2.79
2.36
6.42
6.42
4.38
2.49
2.85
2.49
6.19
6.19
2.97
3.07
1.75

1.25
0.61
1.36
0.70
0.59
1.61
1.61
1.09
0.62
0.71
0.62
1.55
1.55
0.74
0.77
0.44
0.00

0.50
0.24
0.54
0.28
0.24
0.64
0.64
0.44
0.25
0.28
0.25
0.62
0.62
0.30
0.31
0.18
0.00

0.42
0.22
0.25
0.14
0.22
0.14
0.22
0.19
0.19
0.20
0.11
0.21
0.19
0.20
0.29
0.19
0.29

CARGA MUERTA
Peso de la Peso de los Peso de la Viga
Area Tributaria
(m2)
Solera(t)
Losa (t)
Acabados(t)
1.75
0.44
0.18
0.16
3.07
0.77
0.31
0.11
2.97
0.74
0.30
0.11
6.19
1.55
0.62
0.22
6.19
1.55
0.62
0.22
2.49
0.62
0.25
0.11
2.85
0.71
0.28
0.16
2.49
0.62
0.25
0.11
4.38
1.09
0.44
0.16
6.42
1.61
0.64
0.22
6.42
1.61
0.64
0.22
2.36
0.59
0.24
0.11
2.79
0.70
0.28
0.15
5.42
1.36
0.54
0.26
2.44
0.61
0.24
0.30

1.251
0.60901875
1.35588125
0.6967375
0.590625
1.60609375
1.605
1.094625
0.6226875
0.712375
0.6226875
1.54692188
1.54692188
0.74278125
0.76696875
0.4375
0

CARGA VIVA
Peso de la Sobrecarga(t)
Tipico

0.4375
0.76696875
0.74278125
1.54692188
1.54692188
0.6226875
0.712375
0.6226875
1.094625
1.605
1.60609375
0.590625
0.6967375
1.35588125
0.60901875

CARGA VIVA
Peso de la Sobrecarga(t)
Azotea
0.19
0.43
0.22
0.44
0.97

CARGA TOTAL PARA UN PISO TIPICO

CARGA TOTAL PARA LA AZOTEA

PM (t)

PV (t)

Pmuro (t)

PM (t)

PV (t)

Pmuro (t)

2.87
3.84
2.23
4.00
5.69

0.49
1.08
0.56
1.09
2.43

3.36
4.92
2.79
5.09
8.12

2.87
3.84
2.23
4.00
5.69

0.19
0.43
0.22
0.44
0.97

3.07
4.27
2.46
4.43
6.66

0.50
0.24
0.54
0.28
0.24
0.64
0.64
0.44
0.25
0.28
0.25
0.62
0.62
0.30
0.31
0.18
0.00

CARGA VIVA
Peso de la Sobrecarga(t)
Azotea
0.18
0.31
0.30
0.62
0.62
0.25
0.28
0.25
0.44
0.64
0.64
0.24
0.28
0.54
0.24

4.77
3.32
3.70
1.99
2.42
3.88
3.84
2.91
2.23
2.46
1.65
3.68
3.54
2.49
3.19
2.02
2.11

1.25
0.61
1.36
0.70
0.59
1.61
1.61
1.09
0.62
0.71
0.62
1.55
1.55
0.74
0.77
0.44
0.00

6.02
3.93
5.06
2.69
3.01
5.48
5.45
4.01
2.85
3.17
2.28
5.23
5.08
3.23
3.95
2.46
2.11

CARGA TOTAL PARA UN PISO TIPICO

4.77
3.32
3.70
1.99
2.42
3.88
3.84
2.91
2.23
2.46
1.65
3.68
3.54
2.49
3.19
2.02
2.11

0.50
0.24
0.54
0.28
0.24
0.64
0.64
0.44
0.25
0.28
0.25
0.62
0.62
0.30
0.31
0.18
0.00

5.27
3.56
4.24
2.27
2.66
4.52
4.49
3.35
2.48
2.75
1.90
4.30
4.15
2.79
3.49
2.20
2.11

CARGA TOTAL PARA LA AZOTEA

PM (t)

PV (t)

Pmuro (t)

PM (t)

PV (t)

Pmuro (t)

2.12
2.08
2.05
4.18
3.73
1.65
2.17
1.65
2.71
3.81
3.81
1.61
2.07
3.80
3.03

0.44
0.77
0.74
1.55
1.55
0.62
0.71
0.62
1.09
1.61
1.61
0.59
0.70
1.36
0.61

2.56
2.85
2.79
5.73
5.28
2.28
2.88
2.28
3.80
5.42
5.42
2.20
2.77
5.16
3.64

2.12
2.08
2.05
4.18
3.73
1.65
2.17
1.65
2.71
3.81
3.81
1.61
2.07
3.80
3.03

0.18
0.31
0.30
0.62
0.62
0.25
0.28
0.25
0.44
0.64
0.64
0.24
0.28
0.54
0.24

2.30
2.39
2.35
4.80
4.35
1.90
2.46
1.90
3.14
4.46
4.46
1.85
2.35
4.34
3.27

ESFUERZOS PERMITIDOS POR LA NORMA


E070
Pisos
tipicos

azoteas

3
3
3
3
3

1
1
1
1
1

Ptotal (t)

Esfuerso
Axial (t/m2)

13.14
19.04
10.83
19.71
31.03

31.29
42.74
38.82
39.41
67.10

Limite 1
(t/m2)
77.32
77.32
77.32
91.84
91.84

Limite 2
(t/m2)
75
75
75
75
75

Conforme
Conforme
Conforme
Conforme
Conforme

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

23.32
15.35
19.41
10.34
11.70
20.97
20.83
15.36
11.02
12.27
8.74
20.00
19.40
12.48
15.36
9.58
8.46

Pisos
tipicos

azoteas

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

40.38
30.69
56.25
53.04
38.25
63.53
68.09
58.20
42.48
43.74
58.24
68.72
73.92
44.97
37.92
35.46
20.88

Ptotal (t)

Esfuerso
Axial (t/m2)

9.99
10.93
10.72
21.99
20.19
8.74
11.11
8.74
14.55
20.71
20.72
8.45
10.66
19.81
14.19

33.29
54.67
53.59
54.97
67.29
58.24
49.38
58.24
64.67
69.03
69.06
56.32
50.74
54.36
34.02

77.32
91.84
77.32
77.32
77.32
91.84
77.32
77.32
77.32
77.32
77.32
77.32
77.32
77.32
77.32
77.32
77.32

75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75

Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme
Conforme

ESFUERZOS PERMITIDOS POR LA NORMA


E070
Limite 1
Limite 2
(t/m2)
(t/m2)
87.24
75
Conforme
87.24
75
Conforme
87.24
75
Conforme
87.24
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme
77.32
75
Conforme

CARACTERISTICAS DEL PROYECTO FAMILIAR


UBICACIN DEL PROYECTO
DEPARTAMENTO:
PROVINCIA:
DISTRITO:
SUELO DE CIMENTACION:

Cajamarca
Cajamarca
Cajamarca
Arena Gravosa de limo y arcilla

CARACTERISTICAS ARQUITENCTONICAS
Numero de pisos:
Area Bruta:
Area Libre:
Area Construida:
Altura del Piso:
Uso:

3
m2
180
area bruta
30%
m2
126
m2
2.4
vivienda familiar

54 m2

CARACTERISTICAS ESTRUCTURALES
Tipo de estructura
Sistema de techado
Escalera
Peralte de Vigas y Soleras
Peralte de Vigas y dinteles

Albailerai confinada
Losa solida
2 tramos por cada nivel
12
cm
30
cm

DISTRIBUCION ARQUITECTONICA
Comprende cimentaciones ,muros de albaileria y losas o techos de concreto armado
los muros estan distribuido en dos direccones

MATERIALES DE CONSTRUCCION
Ladrillo KK D indutrail tipo IV o V
Mortero:
Resistencia a compresion delas pilas de muros es de:
fm=
concreto a utilizar:
fc=
PEA
PEA

4
50
175
1800

kg/cm2
kg/cm2
kg/m3

2. PREDIMENSIONAMIENTO DE MUROS
ingrese datos de h y t

t > h/20

h=
t=

2.6
13.0
15

3. CALCULO DE LA DENSIDAD MINIMA DE MUROS (NORMA E-70)

m
cm
m

Altura entre piso


Espesor del muro
EL QUE asumimos

DONDE:
Z=
U=
S=
L=

Z.U.S.N
140

factores de zona sismica (E-030)

Es la longitud total del Muro(inlcuyendo columnas,si existiesen). Y "t" es el espe

Z=
U=
S=
N=

DATOS DEL PROYECTO EN ANALISIS


El edificio se encuentra en la ciudad de Cajamarca zona 2 Norma E
Edificio de uso destinado a vivienda Norma E-30)
Suelo de Calidad intermedia Norma E-030)
Numero de pisos del edificio Norma E-030)

0.9
1
1.2
3

DENSIDAD DE MUROS >= Z.U.S.N / 140


REEMPLAZANDO:
DENSIDAD DE MUROS> =
CUADRO DE LONGITUDES DE MUROS:

0.023142857
Densidad(X)=
0.8796
VERIFICANDO
0.8796
>

Direccion en X

MURO
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X20

Lxx(m)
0.70
2.80
1.60
2.20
3.00
2.80
2.80
3.00
2.20
1.60
1.60
0.90

Am

0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

0.1050
0.4200
0.2400
0.3300
0.4500
0.4200
0.4200
0.4500
0.3300
0.2400
0.2400
0.1350

1 P(kg)
472.50
1,890.00
1,080.00
1,485.00
2,025.00
1,890.00
1,890.00
2,025.00
1,485.00
1,080.00
1,080.00
607.50

SUMATORIA 1/2 Edificio


SUMATORIA Edificio

25.2
50.4

3.7800

17,010.00

Densidad (Y)=
VERIFICANDO
0.1204

0.1204

>

Direccion en Y
MURO
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y20
SUMATORIA 1/2 Edificio
SUMATORIA Edificio
SUMATORIA (X,Y)

Lyy(m)
1.7
1.75

Am
0.15
0.15

1 P(kg)

0.255
0.2625

1,147.50
1,181.25

0.52

2,328.75
19,338.75

3.45
6.9

Piso
Piso
1
2
3

Area Losa
83.71
83.71
83.71
Total

CORTANTE BASAL
V= (ZUCS/R)*P

Muros
19,338.75
18,565.20
9,282.60
37,903.95

Losa
20,926.43
20,926.43
20,926.43
41,852.85

PPT
8,370.57
8,370.57
8,370.57
16,741.14

Z=
U=
C=
S=
R=

0.9 Para Cajamarca


1 Para Viviend (E070)
2.5
1.2 Depende del tipo de suelo
6

V=

Distribucin x Piso

PISO

47,822.63

H
1
2
3

Pi
8.2
5.2
2.6

53,523.03
52,749.48
41,374.24

H*Pi
438,888.85
274,297.30
107,573.02
713,186.14

Calculmos el cortante directo x piso


K=
Em=500*fm =
t=
h=
L=

Vd=
fs=

25000
0.15
2.6

5.2

Em=

500*fm=

K=(Em*t)/(4(h/L)^3+3(h/L))

1 Piso
Direccion x

K
x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12

17.35
626.22
170.15
369.53
720.62
626.22
626.22
720.62
369.53
170.15
170.15
35.68
4,622.44

Vd
179.52
6,478.69
1,760.36
3,823.07
7,455.36
6,478.69
6,478.69
7,455.36
3,823.07
1,760.36
1,760.36
369.12

Direccion y
y1

#DIV/0!

#DIV/0!

y2

#DIV/0!
#DIV/0!

#DIV/0!

Hallamos el Centro de masa

x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12

y1
y2

Distancia de los muros Xi hacia eje de la cordenadas


1 Piso
distancia (Xi)
Pi*Xi
5.93 #VALUE!
5.93
3,263.49
5.93
3,359.48
5.93
0.00
5.93
0.00
5.93
0.00
0.075
0.00
0.075
0.00
0.075
0.00
0.075
0.00
0.075
0.00
0.075
0.00
#VALUE!

Distancia de los muros Yi hacia eje de la cordenadas


distancia (Yi)
Pi*Yi
8.92
0.00
14.33
0.00
0.00

Hallamos el Centro de Rigidez


Xcr=

(Yi*K)/K

y1
y2
y3
y4
y5
y6
y7
y8
y9
y10

Distancia de Xi hacia eje de coordenandas Y


1 Piso
Yi
Yi*K
2.80
48.59
4.85
3,037.15
7.35
1,250.62
9.70
3,584.45
12.75
9,187.91
15.95
9,988.16
3.90
2,442.25
5.45
3,927.38
7.50
2,771.48
9.85
1,676.00

y11
y12

Ycr=

x1
x2

12.90
16.10

2,194.97
574.42
40,683.37

(Xi*K)/K
Distancia de Yi hacia eje de coordenandas X
Xi
Xi*K
4.85
#DIV/0!
1.03
#DIV/0!
#DIV/0!

Carlculo de l Excentricidad
Excentricidad teorica (Et)
Etx1=
Ety1=

X1cr-X1cg=
Y1cr-Y1cg=

#VALUE!
#DIV/0!

Excentricidad Accidental (reglamento)


Eax=
Eay=

0.05*Lx=
0.05*Ly=

Excentricidad de Diseo
Ex1=

1.5Etx1+Eax=
Etx1-Eax=

Ey1=

1.5Ety1+Eay=
Ety1-Eay=

Ex2=

1.5Etx2+Eax=
Etx2-Eax=

Ey2=

1.5Ety2+Eay=
Ety2-Eay=

Calculo del momento torsor (MT)

0.7015
0.3825

MTx1=
MTy1=

Ex1*(fs)=
Ey1*(fs)=

#VALUE!
#DIV/0!

MTx2=
MTy2=

Ex2*(fs)=
Ey2*(fs)=

#DIV/0!
#DIV/0!

Analisis de Muros Combinados


T=V(h/L)
Area de Acero en Comulnas
As=1.25*V*h/*fy*L

x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12

y1
y2

Vd
179.52
6,478.69
1,760.36
3,823.07
7,455.36
6,478.69
6,478.69
7,455.36
3,823.07
1,760.36
1,760.36
369.12

h
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

#DIV/0!
#DIV/0!

2.6
2.6

Area de Acero en Vigas Soleras


As=1.25*V/*fy

Asmin=0.1*fc*Ac/fy

Ac=0.9*V/f'c
Area e Acero para Estribos
Av/s=1.5V/d*fy
S=

ltura entre piso


spesor del muro
L QUE asumimos

as,si existiesen). Y "t" es el espesor del Muro

ALISIS
ad de Cajamarca zona 2 Norma E-30)
da Norma E-30)

Dx=
Dy=

0.8796
0.1204

0.0231

2 P(kg)
453.60
1,814.40
1,036.80
1,425.60
1,944.00
1,814.40
1,814.40
1,944.00
1,425.60
1,036.80
1,036.80
583.20

EXISTE UNA DENSIDAD ADECUADA DE MUROS PARA ESTA DIRECCIN

3 P(kg)
226.80
907.20
518.40
712.80
972.00
907.20
907.20
972.00
712.80
518.40
518.40
291.60

16,329.60

0.0231

2 P(kg)

8,164.80

EXISTE UNA DENSIDAD ADECUADA DE MUROS PARA ESTA DIRECCIN

3 P(kg)

1,101.60
1,134.00

550.80
567.00

2,235.60
18,565.20

1,117.80
9,282.60

Alfeizer
702.00
702.00
702.00
1,404.00

s/c
4,185.29
4,185.29
2,092.64
8,370.57

Total
53,523.03
52,749.48
41,374.24
106,272.51

ra Cajamarca
ra Viviend (E070)

epende del tipo de suelo

fs=%V
29429.65
18392.98
7213.30
47822.63

0.62
0.38
0.15
1.00

47822.63

kg/cm2
Vd=K*fs/K

2 Piso
K
2.26
120.22
25.50
62.59
144.06
120.22
120.22
144.06
62.59
25.50
25.50
4.75
857.48
#DIV/0!

Vd
48.40
2,578.76
546.96
1,342.61
3,090.10
2,578.76
2,578.76
3,090.10
1,342.61
546.96
546.96
101.97

#DIV/0!

#DIV/0!
#DIV/0!

#DIV/0!

ros Xi hacia eje de la cordenadas X


2 Piso
distancia (Xi)
Pi*Xi
6.03
0.00
9.92
0.00
8.35
0.00
6.98
0.00
10.39
0.00
0.95
0.00
3.61
0.00
4.75
0.00
10.27
0.00
8.35
0.00
12.76
0.00
6.03
0.00
0.00

ros Yi hacia eje de la cordenadas Y


distancia (Yi)
Pi*Yi
1.75
0.00
1.82
0.00
0.00

a eje de coordenandas Y
2 Piso
Yi
Yi*K
7.57
17.08
7.57
910.08
5.26
134.00
4.38
273.84
4.38
630.26
3.43
411.76
3.43
411.76
3.43
493.41
3.43
214.38
2.53
64.39

X1cg=
X2cg=

#VALUE!
#DIV/0!

Y1cg=
Y2cg=

#DIV/0!
#DIV/0!

X1cr=
X2cr=

8.80127501
4.2046799

1.73
0.08

a eje de coordenandas X
Xi
4.08
5.73

44.11
0.36
3,605.42

Xi*K
#DIV/0!
#DIV/0!
#DIV/0!

Etx2=
Ety2=

Y1cr=
Y2cr=

X2cr-X2cg=
Y2cr-Y2cg=

#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!

(Lx=long mayor en el eje x)


(Lx=long mayor en el eje x)

#VALUE!
#VALUE!

Se elige el mayor

Ex1=

#VALUE!

#DIV/0!
#DIV/0!

Se elige el mayor

Ey1=

#DIV/0!

#DIV/0!
#DIV/0!

Se elige el mayor

Ex2=

#DIV/0!

#DIV/0!
#DIV/0!

Se elige el mayor

Ey2=

#DIV/0!

ea de Acero en Comulnas
=1.25*V*h/*fy*L
L
0.26
0.26
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

As
#VALUE!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0
0

#DIV/0!
#DIV/0!

Am

ea de Acero en Vigas Soleras

=1.25*V/*fy

min=0.1*fc*Ac/fy

#DIV/0!

ea e Acero para Estribos

/s=1.5V/d*fy

#DIV/0!
Ac=20t

300 cm2

4. METRADO DE CARGAS
se utilizaron para el metrado de cargad los siguientes pesos unitarios dados por la norma E.20 Normas de carga
PESOS VOLUMETRICOS
Peso Volumetrico del concreto armado:
Peso Volumetrico de la albaileria
Peso Volumetrico del tarrajeo
TECHOS
Peso Propio de la losa de techo
Altura del Piso:
Peralte de
Vigas y
Soleras

2.4

m2

0.12

2.4 ton/m3
1.8 ton/m3
2 ton/m3
0.288 ton/m3

Sobrecarga(incluso escalera):

0.2 ton/m2

Acabados

0.1 ton/m2

MUROS
Peso de los muros de albaileria con 1 cm de tarrejeo:
peso de los muros de concreto con 1 cm de tarrajeo:
Ventanas:
CALCULO DE AREA TRIBUTARIAS
MUROS EN LA DIRECCION X
AREA DE
INFLUENCIA
MURO
(area
Tributaria)
X1
2.94
X2
3.96
X3
8.28
X4
1.87
X5
2.05
X6
0.46
X7
1.13
X8
4.87
X9
3.94
X10
X11
X12
X13
X14
X15
X16
X17

excepto en azotea :

27.04 ton/m2
36.04 ton/m2
0.02 ton/m2

MUROS EN LA DIRECCION Y
AREA DE
INFLUENCIA
MURO
(area
Tributaria)
Y1
3.15
Y2
2.25
Y3
1.51
Y4
3.67
Y5
2.25
Y6
2.65
Y7
3.53
Y8
Y9
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17

X18
X19
X20

Y18
Y19
Y20

CALCULO DE LA CARGA PROVENIENTE DE LA LOSA DEL TECHO


se concidera un 25% de la sobrecarga es decir:
0.05 tn/m2
Sobrecarga(incluso escalera):
0.2 ton/m2
Acabados
0.1 ton/m2

y,

0.1

se tendra la carga proveniente de la losa de techo.

W=
0.438
tn/m2
con las aresa tributarias halladas y con la carga de la losa de techo se tenemos las siguientes cargas sobre cada muros en las d

MURO
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X20

AREA
2.94
3.96
8.28
1.87
2.05
0.46
1.13
4.87
3.94
0
0
0
0
0
0
0
0
0
0
0

CALCULO DE LA CARGA SOBRE CADA MURO DEBIDO A LA LOSA DE TECHO


PESO (KG)
PESO (Tn)
MURO
AREA
1287.72
1.288
Y1
3.15
1734.48
1.734
Y2
2.25
3626.64
3.627
Y3
1.51
819.06
0.819
Y4
3.67
897.90
0.898
Y5
2.25
201.48
0.201
Y6
2.65
494.94
0.495
Y7
3.53
2133.06
2.133
Y8
0
1725.72
1.726
Y9
0
0.00
0.000
Y10
0
0.00
0.000
Y11
0
0.00
0.000
Y12
0
0.00
0.000
Y13
0
0.00
0.000
Y14
0
0.00
0.000
Y15
0
0.00
0.000
Y16
0
0.00
0.000
Y17
0
0.00
0.000
Y18
0
0.00
0.000
Y19
0
0.00
0.000
Y20
0

CALCULO DE CARGAS DIRECTAS


a los pesos calculados anteriromente se debera aumentar el peso proveniente del peso propio de los muros,peso de los dinte
MUROS CONFINADOS (CORTE A-A)
0.12

Piso Tipico
W=

74.98 ton/m

15.00

2.6

ZONA ALFEIZAR H=1m (VENTANAS CORTE B-B)


0.12
0.3 m

Piso Tipico
W=

1.22 m

1m

ZONA ALFEIZAR H=1.8m (SS.HH CORTE C-C)


Piso tipico
W=

48.7704 ton/m

27.15

ZONA PUERTAS ( CORTE D-D)


Piso tipico
W=

11.7

Tn/m
CARGAS DIRECTAS
MUROS
CONFINADOS
(CORTE A-A)
74.98

CARGAS VERTICALES DEBIDO A LA LOSA DE TECHO CON 25% DE SOBRECARGA Y CARGAS DIRECTAS

MURO

X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X17

0.7
2.8
1.6
2.2
3
2.8
2.8
3
2.2
1.6
1.6
0.9
0
0
0
0
0

Xi

CARGA PISO
TIPICO

PESO TOTAL ESFUERZO EN


ACUMULADO
EL 1 PISO
EN EL 1 PISO
(Kg/cm2)

X18
X19
X20

0
0
0

a E.20 Normas de carga

0.1

ton/m2

ton/m2

de acabados

ntes cargas sobre cada muros en las dos direcciones:

SA DE TECHO
PESO (KG)
1379.700
985.500
661.380
1607.460
985.500
1160.700
1546.140
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

PESO (Tn)
1.380
0.986
0.661
1.607
0.986
1.161
1.546
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

propio de los muros,peso de los dinteles en puerta y ventanas,etc.

tn/m

AS DIRECTAS

CARGAS DIRECTAS
ZONA
ZONA
ALFEIZAR
ALFEIZAR
H=1m
H=1.8m
(VENTANAS
(SS.HH
CORTE B-B) CORTE C-C)
27.15
48.77

ZONA
PUERTAS (
CORTE D-D)
11.70

PEA=
fm=

1800 kg/m3
50 kg/cm2

Direccion x
L1
x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13
x14
x15

t
0.25
0.35
0.30
0.18
0.28
0.30
1.50
1.00
0.90
0.61
0.60
0.30
1.40
2.43
2.78

Am
0.20
0.20
0.20
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

0.05
0.07
0.06
0.03
0.04
0.05
0.23
0.15
0.14
0.09
0.09
0.05
0.21
0.36
0.42

1 P(kg)
2 P(kg)
225.00
108.00
315.00
151.20
270.00
129.60
121.50
58.32
189.00
90.72
202.50
97.20
1,012.50
486.00
675.00
324.00
607.50
291.60
411.75
197.64
405.00
194.40
202.50
97.20
945.00
453.60
1,640.25
787.32
1,876.50
900.72

2.02
Direccion y
y1
y2
y3
y4
y5
y6

Piso
1
2

3.05
2.4
3.35
2.93
0.7
1.34

0.15
0.15
0.15
0.15
0.15
0.15

0.46
0.36
0.50
0.44
0.11
0.20
2.07

2,058.75
1,620.00
2,261.25
1,977.75
472.50
904.50
18,393.75

988.20
777.60
1,085.40
949.32
226.80
434.16
8,829.00

Area Losa
Muros
Losa
PPT
Alfeizer
75.23
18,393.75
18,807.25
7,522.90
3,708.72
75.23
8,829.00
18,807.25
7,522.90
3,708.72
27,222.75
37,614.50
15,045.80
7,417.44
Total

V=

(ZUCS/R)*P

Z=
U=
C=
S=
R=

0.4 Para Cajamarca


1 Para Viviend (E070)
2.5
1.2 Depende del tipo de suelo
6

V=
Distribucin x Piso
1
2

18,588.53
H

Pi
2.8
5.4

H*Pi
%
52,194.07
146,143.40
40,748.60
220,042.41
366,185.81

fs=%V
0.40 7418.61446
0.60 11169.9185
1.00
18,588.53

Verificacin de densidad de muros


ZUSN/140=
Dx=
Dy=

0.00685714

Amx/At=
Amy/At=

0.4946789 >ZUSN/140
0.5053211 >ZUSN/140

OK
OK

Calculmos el cortante directo x piso


Em=

500*fm=

K=(Em*t)/(4(h/L)^3+3(h/L))

Direccion x

K
x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13

25000 kg/cm2
Vd=K*fs/K

1 Piso
Vd
K
1.10
14.05
3.01
38.29
1.90
24.20
0.31
3.95
1.16
14.78
1.43
18.15
144.06
1,833.63
48.01
611.12
35.68
454.12
11.63
147.99
11.08
141.01
1.43
18.15
120.22
1,530.21

2 Piso
Vd
0.14
0.38
0.24
0.04
0.15
0.18
21.18
6.49
4.75
1.50
1.43
0.18
17.35

6.09
16.69
10.52
1.71
6.42
7.89
930.83
285.10
208.91
65.83
62.66
7.89
762.57

x14
x15

462.42
616.98
1,460.42

5,885.82
7,853.07

82.21
117.96
254.17

3,612.71
5,184.09

y1
y2
y3
y4
y5
y6

744.75
449.88
893.20
687.18
17.35
107.02
2,899.38

4,774.74
2,884.24
5,726.51
4,405.66
111.25
686.13

150.37
79.47
191.16
135.46
2.26
15.28
574.01

2,926.22
1,546.53
3,719.94
2,635.95
43.91
297.37

Direccion y

Hallamos el Centro de masa

x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13
x14
x15

y1
y2
y3
y4
y5
y6

1 Piso
2 Piso
distancia (Xi)
Pi*Xi
distancia (Xi)
Pi*Xi
2.13
478.13
2.13
229.50
6.03
1,897.88
6.03
910.98
9.92
2,677.05
9.92
1,284.98
8.35
1,014.53
8.35
486.97
6.98
1,319.22
6.98
633.23
10.39
2,103.98
10.39
1,009.91
0.95
956.81
0.95
459.27
3.61
2,436.75
3.61
1,169.64
4.75
2,885.63
4.75
1,385.10
10.27
4,226.61
10.27
2,028.77
8.35
3,381.75
8.35
1,623.24
12.76
2,582.89
12.76
1,239.79
6.03
5,693.63
6.03
2,732.94
9.92
16,263.08
9.92
7,806.28
12.91
24,216.23
12.91
11,623.79
72,134.15
34,624.39
distancia (Yi)
5.97
1.75
1.82
1.72
0.50
0.90

Hallamos el Centro de Rigidez

Pi*Yi
distancia (Yi)
12,290.74
5.97
2,835.00
1.75
4,115.48
1.82
3,391.84
1.72
236.25
0.50
814.05
0.90
23,683.35

Pi*Yi
5,899.55
1,360.80
1,975.43
1,628.08
113.40
390.74
11,368.01

Xcr=

(Yi*K)/K
1 Piso
Yi

y1
y2
y3
y4
y5
y6
y7
y8
y9
y10
y11
y12
y13
y14
y15

Ycr=

2 Piso
Yi*K

7.57
7.57
7.57
5.26
4.38
4.38
3.43
3.43
3.43
3.43
2.53
1.73
0.08
0.08
0.08

Yi

8.35
22.77
14.39
1.63
5.08
6.24
493.41
164.44
122.20
39.82
27.97
2.47
9.02
34.68
46.27
998.75

Yi*K
7.57
7.57
7.57
5.26
4.38
4.38
3.43
3.43
3.43
3.43
2.53
1.73
0.08
0.08
0.08

1.05
2.88
1.81
0.20
0.64
0.79
72.54
22.22
16.28
5.13
3.60
0.31
1.30
6.17
8.85
143.77

(Xi*K)/K
Xi

x1
x2
x3
x4
x5
x6

Xi*K
5,864.89
1,833.24
5,113.59
5,411.54
207.45
1,493.48
19,924.18

7.88
4.08
5.73
7.88
11.96
13.96

Xi
7.88
4.08
5.73
7.88
11.96
13.96

Xi*K
1184.19603
323.856947
1094.40329
1066.72653
26.9738048
213.254037
3,909.41

Carlculo de l Excentricidad
Excentricidad teorica (Et)
Etx1=
Ety1=

X1cr-X1cg=
Y1cr-Y1cg=

-7.24381976
4.32384361

Etx2=
Ety2=

Excentricidad Accidental (reglamento)


Eax=
Eay=

0.05*Lx=
0.05*Ly=

0.7015 (Lx=long mayor en el eje x)


0.3825 (Lx=long mayor en el eje x)

X2cr-X2cg=
Y2cr-Y2cg=

Excentricidad de Diseo
Ex1=

1.5Etx1+Eax=
Etx1-Eax=

10.16422963 Se elige el mayor


7.945319756

Ey1=

1.5Ety1+Eay=
Ety1-Eay=

6.868265415 Se elige el mayor


3.94134361

Ex2=

1.5Etx2+Eax=
Etx2-Eax=

11.74459565 Se elige el mayor


6.660563768

Ey2=

1.5Ety2+Eay=
Ety2-Eay=

6.776578466 Se elige el mayor


3.880218977

Calculo del momento torsor (MT)


MTx1= Ex1*(fs)=
MTy1= Ey1*(fs)=

188,938.12
127,670.98

MTx2= Ex2*(fs)=
MTy2= Ey2*(fs)=

131,186.18
75,693.83

3 P(kg)
486,000.00

s/c
3,761.45
1,880.73
5,642.18

Total
52,194.07
40,748.60
92,942.67

X1cg=
X2cg=

7.9277003
7.9277003

Y1cg=
Y2cg=

2.54803558
2.54803558

X1cr=
X2cr=

0.68388054
0.56563653

Y1cr=
Y2cr=

6.87187919
6.81075456

-7.36206377
4.26271898

Ex1=

10.1642296

Ey1=

6.86826541

Ex2=

11.7445957

Ey2=

6.77657847

PEA=
fm=

1800 kg/m3
50 kg/cm2

Direccion x
L1
x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13
x14
x15

t
3.75
3.55
3.73
0.80
1.65
3.28
1.39
0.78
0.60
3.03
0.80
1.15
3.55
3.73
1.75

Am
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

0.56
0.53
0.56
0.12
0.25
0.49
0.21
0.12
0.09
0.45
0.12
0.17
0.53
0.56
0.26

1 P(kg)
2 P(kg)
2,531.25
1,215.00
2,396.25
1,150.20
2,517.75
1,208.52
540.00
259.20
1,113.75
534.60
2,214.00
1,062.72
938.25
450.36
526.50
252.72
405.00
194.40
2,045.25
981.72
540.00
259.20
776.25
372.60
2,396.25
1,150.20
2,517.75
1,208.52
1,181.25
567.00

5.03
Direccion y
y1
y2
y3
y4
y5
y6

Piso
1
2

3.05
2.4
3.35
2.93
0.7
1.34

0.15
0.15
0.15
0.15
0.15
0.15

0.46
0.36
0.50
0.44
0.11
0.20
2.07

2,058.75
1,620.00
2,261.25
1,977.75
472.50
904.50
31,934.25

988.20
777.60
1,085.40
949.32
226.80
434.16
15,328.44

Area Losa
Muros
Losa
PPT
Alfeizer
75.23
31,934.25
18,807.25
7,522.90
3,708.72
75.23
15,328.44
18,807.25
7,522.90
3,708.72
47,262.69
37,614.50
15,045.80
7,417.44
Total

V=

(ZUCS/R)*P

Z=
U=
C=
S=
R=

0.4 Para Cajamarca


1 Para Viviend (E070)
2.5
1.2 Depende del tipo de suelo
6

V=
Distribucin x Piso
1
2

22,596.52
H

Pi
2.8
5.4

H*Pi
%
65,734.57
184,056.80
47,248.04
255,139.39
439,196.19

fs=%V
0.42 9469.67073
0.58 13126.8503
1.00
22,596.52

Verificacin de densidad de muros


ZUSN/140=

0.00685714

Dx=
Dy=

0.70894103 >ZUSN/140
0.29105897 >ZUSN/140

Amx/At=
Amy/At=

OK
OK

Calculmos el cortante directo x piso


Em=

500*fm=

25000 kg/cm2
Vd=K*fs/K

K=(Em*t)/(4(h/L)^3+3(h/L))

Direccion x

K
x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13

1 Piso
Vd
1,098.68
995.06
1,088.25
25.50
184.02
858.05
117.96
23.71
11.08
735.07
25.50
70.74
995.06

K
3,296.86
2,985.91
3,265.56
76.52
552.21
2,574.78
353.98
71.15
33.24
2,205.76
76.52
212.28
2,985.91

2 Piso
Vd
252.94
221.03
249.66
3.35
27.85
181.21
17.00
3.11
1.43
147.83
3.35
9.78
221.03

2,046.85
1,788.62
2,020.31
27.14
225.35
1,466.34
137.53
25.18
11.54
1,196.27
27.14
79.15
1,788.62

x14
x15

1,088.25
213.37
7,530.33

3,265.56
640.27

249.66
32.94
1,622.18

2,020.31
266.52

y1
y2
y3
y4
y5
y6

744.75
449.88
893.20
687.18
17.35
107.02
2,899.38

5,804.25
3,506.13
6,961.24
5,355.59
135.24
834.07

150.37
79.47
191.16
135.46
2.26
15.28
574.01

3,438.88
1,817.48
4,371.66
3,097.75
51.60
349.47

Direccion y

Hallamos el Centro de masa

x1
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13
x14
x15

y1
y2
y3
y4
y5
y6

1 Piso
2 Piso
distancia (Xi)
Pi*Xi
distancia (Xi)
Pi*Xi
2.13
5,378.91
2.13
2,581.88
6.03
14,437.41
6.03
6,929.96
9.92
24,963.49
9.92
11,982.48
8.35
4,509.00
8.35
2,164.32
6.98
7,773.98
6.98
3,731.51
10.39
23,003.46
10.39
11,041.66
0.95
886.65
0.95
425.59
3.61
1,900.67
3.61
912.32
4.75
1,923.75
4.75
923.40
10.27
20,994.49
10.27
10,077.36
8.35
4,509.00
8.35
2,164.32
12.76
9,901.07
12.76
4,752.51
6.03
14,437.41
6.03
6,929.96
9.92
24,963.49
9.92
11,982.48
12.91
15,244.03
12.91
7,317.14
174,826.79
83,916.86
distancia (Yi)
5.97
1.75
1.82
1.72
0.50
0.90

Hallamos el Centro de Rigidez

Pi*Yi
distancia (Yi)
12,290.74
5.97
2,835.00
1.75
4,115.48
1.82
3,391.84
1.72
236.25
0.50
814.05
0.90
23,683.35

Pi*Yi
5,899.55
1,360.80
1,975.43
1,628.08
113.40
390.74
11,368.01

Xcr=

(Yi*K)/K
1 Piso
Yi

y1
y2
y3
y4
y5
y6
y7
y8
y9
y10
y11
y12
y13
y14
y15

Ycr=

7.57
7.57
7.57
5.26
4.38
4.38
3.43
3.43
3.43
3.43
2.53
1.73
0.08
0.08
0.08

2 Piso
Yi*K
8,317.04
7,532.61
8,238.09
134.00
805.11
3,753.98
404.03
81.21
37.95
2,517.63
64.39
122.39
74.63
81.62
16.00
32,180.66

Yi

Xi*K
5,864.89
1,833.24
5,113.59
5,411.54
207.45
1,493.48
19,924.18

Xi

7.57
7.57
7.57
5.26
4.38
4.38
3.43
3.43
3.43
3.43
2.53
1.73
0.08
0.08
0.08

Yi*K
1,914.79
1,673.22
1,889.96
17.63
121.84
792.78
58.21
10.66
4.88
506.32
8.47
16.92
16.58
18.72
2.47
7,053.45

7.88
4.08
5.73
7.88
11.96
13.96

Xi*K
1184.19603
323.856947
1094.40329
1066.72653
26.9738048
213.254037
3,909.41

(Xi*K)/K
Xi

x1
x2
x3
x4
x5
x6

7.88
4.08
5.73
7.88
11.96
13.96

Carlculo de l Excentricidad
Excentricidad teorica (Et)
Etx1=
Ety1=

X1cr-X1cg=
Y1cr-Y1cg=

-3.44873052
4.32384361

Etx2=
Ety2=

Excentricidad Accidental (reglamento)


Eax=
Eay=

0.05*Lx=
0.05*Ly=

0.7015 (Lx=long mayor en el eje x)


0.3825 (Lx=long mayor en el eje x)

X2cr-X2cg=
Y2cr-Y2cg=

Excentricidad de Diseo
Ex1=

1.5Etx1+Eax=
Etx1-Eax=

4.471595774 Se elige el mayor


4.150230516

Ey1=

1.5Ety1+Eay=
Ety1-Eay=

6.868265415 Se elige el mayor


3.94134361

Ex2=

1.5Etx2+Eax=
Etx2-Eax=

5.762626573 Se elige el mayor


2.672584382

Ey2=

1.5Ety2+Eay=
Ety2-Eay=

6.776578466 Se elige el mayor


3.880218977

Calculo del momento torsor (MT)


MTx1= Ex1*(fs)=
MTy1= Ey1*(fs)=

101,042.51
155,198.90

MTx2= Ex2*(fs)=
MTy2= Ey2*(fs)=

75,645.14
88,955.13

s/c
3,761.45
1,880.73
5,642.18

Total
65,734.57
47,248.04
112,982.61

X1cg=
X2cg=

7.72220185
7.72220185

Y1cg=
Y2cg=

2.54803558
2.54803558

X1cr=
X2cr=

4.27347133
4.34811747

Y1cr=
Y2cr=

6.87187919
6.81075456

-3.37408438
4.26271898

Ex1=

4.47159577

Ey1=

6.86826541

Ex2=

5.76262657

Ey2=

6.77657847