Sepam Model Selection Tool

Model Number: SQ1 S23 B 1 O 0 A 0 A 0 Cost of Sepam Unit: $1,483.00


Device Type Provides Protection For: Includes Metering Values:
Display Type
Current Option
Digital I/O Option
Communications Option
RTD Option (Not available on substation or busbar models)
Analog Outputs Description:
Logipam Programming (Series 80 only)
Sync Check Option (ANSI - 25, Series 80 Only)
* denotes a default component
You have selected a (S23) 20 Series Substation Protection Relay (24-250Vdc & 120-240Vac), Basic display
included in base unit, (CCA634) 1/5A CT inputs (3PH and Ground/Residual or ZSCT), No I/O module, No
communications card, No temperature sensor inputs (RTD module), No Analog outputs, No Logipam programming
ability, No Synch Check Module.
Component Numbers
SEPAM PRICING GUIDE
S
Q
1
R
e
l
a
y

B
a
s
e

M
o
d
e
l
D
i
s
p
l
a
y
C
u
r
r
e
n
t
I
/
O
C
o
m
s
R
T
D
'
s
A
n
a
l
o
g

O
u
t
L
o
g
i
p
a
m
S
y
n
c
h

C
h
e
c
k
Relay Base
Model Competition
Example SQ1 T87 A 1 J 1 A 1 A 0
C86 C86
Competition
S23 S23
Competition
S40 S40
Competition
S42 S42
Competition
S43 S43
S80 S80 Competition
S82 S82 Competition
S84 S84 Competition
B21 B21
B22 B22
Competition
B80 B80
B83 B83
G40 G40 Competition
G82 G82 Competition
G87 G87 Competition
G88 G88 Competition
M20 M20 Competition
M41 M41 Competition
M81 M81 Competition
M87 M87 Competition
M88 M88 Competition
T23 T23 Competition
T40 T40 Competition
T42 T42 Competition
T81 T81
T82 T82 Competition
T87 T87 Competition
Display
A
B
P MimicBus
R
DSM303 (Series
20 & 40 Only)
C
DSM303 (Series
80 Only)
Current
1 CCA634
2 CCA630
3 CCA671
I/O for models 20 & 40 (will not work with model 80)
O without
A
MES114
B
MES114E
C MES114F
I/O for models 80 Max. 3 per base unit (will not work with models 20 & 40)
O without No I/O
D MES120 14 Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only)
E MES120 28 Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only)
F MES120 42 Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only)
G MES120G 14 inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only)
H MES120G 28 inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only)
I MES120G 42 inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only)
J MES120H 14 inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only)
K MES120H 28 inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only)
L MES120H 42 inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only)
Communications
0 without
1 ACE959
2
ACE969TP2
3
ACE969FO2
4 ECI850
5 ACE850
RTD used only for the following applications: Motor, Generator, Capacitor or Transformer
A without
B
MET1482 (One
Module)
C
MET1482 (Two
Modules)
Analog Output
0 without
1 MSA141
Series 80 Options
A without
B SFT080
0 without
1 MCS025
SQ1 T87 A 1 J 1 A 0 A 0
Accessories - Not to be included in the relay part number
RTM 3090RTM317
CSH30 CSH30
CSCT120 CSH120
CSCT200 CSH200
EGX100 EGX100
EGX400 EGX400
ECI850 ECI850
ACE850 ACE850
ABL8RPS24030
ABL8RPS24050
Software
SFT2841KIT
SFT2841KIT
SFTKIT
SEPAM PRICING GUIDE
Competition
Description List Price
Capacitor
80 Series Capacitor Relay, 24-250Vdc $3,825.00
Compare Substation Relays
20 Series Substation Protection Relay, 24-250Vdc & 120-240Vac $1,483.00
40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac $2,713.00
40 Series Substation, 24-250Vdc & 120-240Vac
Applincation: Substation - S40A + Directional 67, 67N protection. Parallel main protection. ZSI
and ATS
$3,559.00
40 Series Substation, 24-250Vdc & 120-240Vac
$2,330.00
80 Series Substation Protection Relay, 24-250Vdc
$3,570.00
80 Series Substation Protection Relay, 24-250Vdc
$3,880.00
80 Series Substation Protection Relay, 24-250Vdc
$4,480.00
Compare Busbar Relays
20 series Busbar Protection Relay 24-250Vdc & 120-240Vac $1,953.00
20 series Busbar Protection Relay 24-250Vdc & 120-240Vac $2,266.00
80 Series Busbar Protection Relay, 24-250Vdc $3,750.00
80 Series Busbar Protection Relay, 24-250Vdc $3,950.00
Compare Generator Relays
40 Series Generator Protection relay, 24-250Vdc & 120-240Vac $3,609.00
80 Series Generator Protection Relay, 24-250Vdc
$3,870.00
80 Series Generator Protection Relay, 24-250Vdc
$4,220.00
80 Series Generator Protection Relay, 24-250Vdc
$5,222.00
Compare Motor Relays
20 series Motor Protection Relay 24-250Vdc & 120-240Vac
$2,009.00
40 Series Motor Protection Relay, 24-250Vdc & 120-240Vac, $3,129.00
80 Series Motor Protection Relay, 24-250Vdc,
$3,240.00
80 Series Motor Protection Relay, 24-250Vdc,
$3,550.00
80 Series Motor Protection Relay, 24-250Vdc,
$3,840.00
Compare Transformer Relays
20 series Transformer Relay 24-250Vdc & 120-240Vac
$1,957.00
40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac $2,961.00
40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac $3,808.00
80 Series Transformer Protection Relay, 24-250Vdc
$3,830.00
80 Series Transformer Protection Relay, 24-250Vdc
$4,130.00
80 Series Transformer Protection Relay, 24-250Vdc
$4,580.00
Advanced display included in base unit $300.00
Standard LED Display included in base uniit $0.00
MimicBus Graphical Display (for series 80 only)
$450.00
Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 20/40
AMT840 (Replaces integrated display) $540.00
Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 80
AMT880 (Replaces integrated display) $654.00
5A input standard on relays for current measurement, not included on voltage only relays $0.00
Only for use with CSH120, 200 ground fault sensor, and CSH30 $0.00
25/3750A LPCT Connector for All SEPAM Series
Note: Used with Motorpact or other medium voltage starter, includes CSH30
$531.00
I/O for models 20 & 40 (will not work with model 80)
No I/O $0.00
10 Inputs + 4 Outputs Module, 24-48Vdc and 120-250V ac Capacitor Trip application
$616.00
10 Inputs + 4 Outputs Module, 110-125 Vdc, 110Vac
$595.00
10 Inputs + 4 Outputs Module, 220-250Vdc, 220-240Vac $785.00
I/O for models 80 Max. 3 per base unit (will not work with models 20 & 40)
$0.00
14 Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only) $770.00
28 Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only) $1,540.00
42 Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only) $2,310.00
14 inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $770.00
28 inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $1,540.00
42 inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $2,310.00
14 inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $770.00
28 inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $1,540.00
42 inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $2,310.00
No communications card $0.00
1 RS 485 Modbus Port (12 or 24 VDC Power) included with all relays $398.00
(2)RS485 2wire ports, Port 1 Modbus, Port 2 Modbus, DNP3 or IEC 60870 (requires 110-
240VAC/ 24-250DC ext. power). Includes CCA612 CAT5 cable. $275.00
(1) RS485 2wire Modbus + (1) Fiber Modbus, DNP3 or IEC 60870 (requires110-240VAC/ 24-
250DC). Includes CCA612 CAT5 cable. $771.00
1 x RS485 IEC 61850 protocol port $1,000.00
61850 + Modbus TCPIP Ethernet Module (not currently availible)
RTD used only for the following applications: Motor, Generator, Capacitor or Transformer
No RTD module $0.00
8 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5
cable. Note: Series 20, 40 & 80
$695.00
16 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5
cable. Note: Series 40 & 80 only
$1,390.00
No Analog Output $0.00
1 Analog output module, software selectable 0/10mA, 0/20mA or 4/20mA (includes CCA77X
cable) $631.00
No Logipam $0.00
Logipam firmware (PLC base) $250.00
No Synch Check Module $0.00
Sync-check Module_ANSI-25 for model 80 only (includes ATM840 Surface Mount Plate) $1,540.00
Accessories - Not to be included in the relay part number
Ride Through Module Recommented for AC control voltage application (for all series 20, 40
and 80)
$574.00
Interposing CT for Residual ground current input, use with LPCT $116.00
Ground sensor CT - 120mm window (zsct) $235.00
Ground sensor CT - 200mm window (zsct) $378.00
Ethernet Gateway; RS-485/RS232, 10/100 BASE TX Transparent ready $950.00
Ethernet Gateway;(2) RS-485 serial ports,10/100T,100FX (Fiber),8 imbedded web pages,
Modbus Protocol $2,460.00
1 Ethernet port 10/100 base T (Protocol: Modbus or IEC 61850) (Requires ACE Com Card) $850.00
2 Ethernet ports 10/100 base T Only for Series 80 (Protocol: Modbus or IEC 61850) does
not require ACE Com Card $850.00
Power Supply: Input 110-480VAC, Output 24VDC 3A_for upto 15 comm module $180.00
Power Supply: Input 110-480VAC, Output 24VDC 5A_for upto 25 comm module $240.00
Relay Programming Software includes CD w/relay connector cable & USB / Serial cable,
necessary for programming and troubleshooting relays) $275.00
Relay Programming Software includes SFT 2841 CD & SFT 2885 Logipam programming CD
w/relay connector cable & USB / Serial cable Note: must have Logipam option on a series 80
relay to use Logipam programming software
$495.00
Note: SFT2841 to be a free download (like ION Setup). The kit includes the program on
a disk and the connection cables. Kit price may be reduced
Competition
Description List Price
General Selection Guide
Protection Functions Applications
Base Specific Substation Bus Transformer Motor
Current Protections
S20 T20 M20
Breaker Failure S23 T23
Voltage and Frequency
Protection
B21
disconnection by "rate of
change of frequency"
B22
Base Specific Substation Bus Transformer Motor
Current, Voltage and
Frequency Protection
S40 T40
directional ground fault S41 M41
directional ground fault and
phase overcurrent
S42 T42
Base Specific Substation Bus Transformer Motor
Current, Voltage and
Frequency Protection
S80 B80
directional ground fault S81 T81 M81
directional ground fault and
phase overcurrent
S82 T82
disconnection by "rate of
change of frequency"
S84
Current, Voltage and
Frequency Protection
Transformer and
transformer-machine unit
differential
T87 M88
Machine Differential M87
Current, Voltage and
Frequency Protection
Voltage and frequentcy
protection for two sets of
bus
B83
Current, Voltage and
Frequency Protection
Capacitor bank unbalance
Generator Capacitor
Generator Capacitor
G40
Generator Capacitor
G82
G88
G87
C86
SEPAM Knowledgebase and FAQ's
SQ1B21A SQ1G40A SQ1C86A
SQ1M20A SQ1M41A SQ1G82A
SQ1S23A SQ1S40A SQ1G87A
SQ1T23A SQ1S42A SQ1G88A
SQ1T40A SQ1M81A
SQ1T42A SQ1M87A
SQ1M88A
SQ1S80A
SQ1S82A
SQ1S84A
SQ1T82A
SQ1T87A
SEPAM Links:
Substation - (S40A + Directional 67,
67N) protection. Parallel main protection,
ZSI and ATS
Substation - Current, protection of low-
capacitance Feeders / Mains
in impedance grounded or solidly grounded
neutral systems. Capacitor feeder bank
(delta connection)
Transformer - Current and voltage
protection.
Current Protection Only
Motor, FVNR, FVR 100-1500HP-
Current protection without voltage
monitoring
Series 20 control voltage
24-250V DC, or 110-220V AC (for AC use RTM
#3090RTM317)
Series 40 control voltage
24-250V DC, or 110-220V AC (for AC use RTM
#3090RTM317)
SEPAM Tech Library; docs, curves and specifications
SEPAM Software downloads
Transformer - (T82 + 87T). Current and
voltage + Directional. Parallel transformer
main & differential protection
Substation - (S80A + Directional 67,
67N, 27,59, 59N, 81L, 81R, 32P, 37P).
Protection of main or tie CB with load
shedding, ZSI & ATS
Transformer - Current protection without
voltage monitoring
Current Protection Only
Transformer - Current and voltage +
Directional. Parallel transformer main
protection
Motor feeder - Current protection with
voltage monitoring. For motor self balance
Diff "87M" add Basler BE3-50/51.
Motor - (M81 + 87M)Current protection
with voltage monitoring and motor self
balance Diff "87M" or full percentage diff
Substation - Current & Voltage,
protection of low-capacitance Feeders /
Mains in impedance grounded or solidly
grounded neutral systems
Substation - (S80A + Directional 67,
67N). Protection of main or tie CB with load
shedding, ZSI & ATS
Series 80 control voltage
24-250V DC, for 110-220V AC (use RTM
#3090RTM317)
Motor-transformer unit differential
protection
Transformer - (T40A + Directional 67,
67N). Current and voltage + Directional.
Parallel transformer main protection
SEPAM Relays Series 80
Motor, FVNR, RVAT, FVR, FV2S, FR
500- 5000HP - Current protection with
voltage monitoring. For motor self-balance
Diff "87M" add Basler BE3-50/51.
Substation - Current & Voltage,
protection of low-capacitance Feeders /
Mains in impedance grounded or solidly
grounded neutral systems. Capacitor bank
(delta connection)
Capacitor bank - Double-wye
connected protection with 1 to 4 steps
Generator Protection coupled to other
generators or to a network
Generator - Current protection with
voltage monitoring and gen self-balance
Diff "87M" or full percentage diff
Generator-transformer unit differential
protection
Voltage/Frq Protection Only
Current Protection Only
SEPAM Relays Series 20 SEPAM Relays Series 40
Generator - Current, Voltage and
Frequency Protection of a separate
generator. For Gen-self-balance Diff "87M"
add Basler BE3-50/51.
Bus - Voltage and Frequency
protection and ATS
ANSI Protection Functions B21 B22 B80 B83
25 Synch-check
27 Undervoltage (L-L) 2/1
(3)
2/1
(3)
4 4
27D Positive sequence undervoltage 2 2 2 2
27R Remanent undervoltage 1 1 2 2
27S Undervoltage (L-N)
30 Annunciation
46 Negative sequence / unbalance 2 2
47 Negative Sequence Overvoltage 2 2
50/51 Phase Overcurrent 8 8
50BF Breaker Failure 1 1
50N/51N Ground Fault 8 8
50G/51G Sensitive Ground Fault
59 Overvoltage (L-L or L-N) 2 2 4 4
59N Neutral voltage displacement 2 2 2 2
81H Overfrequency 1 1 2 2
81L Underfrequency 2 2 4 4
81R Rate of change of frequency (df/dt) _ (SQ1B22A
only_use with Gen application) 1
86 Latching, Lockout
94/69 CB_Control Logic
Note:
Optional The Difference between B80 and B83?
(1) Protection functions with 2 groups of settings B83: monitors Line and Bus voltage
(2) With optional MSC025 Synch Check Module (2 sets of VT's)
(3) 2 Undervoltage (L-L) and 1 undervoltage (L-N)
Comparison of ANSI features on Busbar Protection Relays
The numbers in the matrix denote the number of trip points that can be
configured for this ANSI code.
Metering Values Acc. B21 B22 B80 B83
Current 1,2,3 + - .5% X X
Current Peak Demand + - .5% X X
Current Demand + - .5% X X
Current Residual +-1% X X
Voltage L-N & L-L + - .5% X X
+-1% X X
Voltage Residual +-1% X X X X
Neutral Point Voltage +-1% X X
Voltage Neg. Sequence 1,2,3 + - 2% X X
Voltage Pos. Sequence 1,2,3 + - 2% X X X X
KW +-1% X X
KVA +-1% X X
KVAr +-1% X X
KWh (Calculated) +-1% X X X X
KVArh (Calculated) +-1% X X
KWh (Pulse Counting) +-1%
KVArh (Pulse Counting) +-1%
KVAh +-1%
Frequency .01Hz X X X X
Temperature + - 1 Deg +- 1 Deg C +- 1 Deg C
Harmonic distortion (I THD & V THD) +-1% X X
Peak KW demand +-1% X X
Peak KVAr demand +-1% X X
Power Factor -1 - 0 - +1 0.01 X X
Rotation Speed + - 1 RPM
Metering Parameters
Comparison of ANSI features on Generator Protection Relays
ANSI Protection Functions G40 G82 G87 G88
12 Overspeed (2 set points)
14 Underspeed (2 set points)
21B Underimpedance 1 1 1
24 Flux control (V/Hz) 2 2 2
25 Synch-check
26/63 Thermostat / Buchholz
27/27S Undervoltage (L-L or L-N) 2 4 4 4
27D Positive sequence undervoltage 2 2 2
27R Remanent undervoltage 2 2 2
27TN/64G2
64G
Third Harmonic Undervoltage & 100% stator
ground fault 2 2 2
30 Annunciation
32P Directional active overpower 1 2 2 2
32Q/40/55 Directional reactive overpower 1 1 1 1
37P Directional active overpower 2
38/49T Temperature monitoring
8 RTD's 16 RTD's 16 RTD's 16 RTD's
40 Field loss underimpedance 1 1 1
46 Negative sequence unbalance 2 2 2 2
47 Negative sequence overvoltage 1 2 2 2
49RMS Thermal overload 2 2 2 2
50/27 Inadvertant energization 1 1
50/51 Phase overcurrent 4 8 8 8
50BF Breaker failure 1 1 1 1
50V/51V Voltage restrained phase overcurrent 1 2 2 2
59 Overvoltage (L-L or L-N) 2 4 4 4
59N Neutral voltage displacement 2 2 2 2
60/60FL CT/VT supervision Y Y Y Y
64REF Restricted ground fault 2 2
67 Directional phase overcurrent 2 2 2
67N/67NC Directional ground fault 2 2 2
68 Zone Selective Interlock (ZSI)
74 Trip circuit supervision
78PS Pole slip (loss of synch) 1 1 1
81H Overfrequency 2 2 2 2
81L Underfrequency 4 4 4 4
86 Latching, Lockout
87M Machine Differential 1
87T Transformer differential 1
94/69 CB_Control Logic
Note:
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module
The numbers in the matrix denote the number of trip points that can be configured for this ANSI
code.
8
50N/51N
50G/51G
Ground fault / Sensitive ground fault
4 8 8
Metering Values Accuracy G40 G82 G87 G88
Current 1,2,3 + - .5% X X X X
Current Peak Demand + - .5% X X X X
Current Demand + - .5% X X X X
Current Residual +-1% X X X X
Voltage L-N & L-L + - .5% X X X X
Voltage Residual +-1% X X X X
Neutral Point Voltage +-1% X X X
Voltage Neg. Sequence 1,2,3 + - 2% X X X X
Voltage Pos. Sequence 1,2,3 + - 2% X X X X
KW +-1% X X X X
KVA +-1% X X X X
KVAr +-1% X X X X
KWh (Calculated) +-1% Op X X X
KVArh (Calculated) +-1% Op X X X
KWh (Pulse Counting) +-1% Op
KVArh (Pulse Counting) +-1% Op
KVAh +-1%
Frequency .01Hz X X X X
Temperature + - 1 Deg Op +- 1 Deg C +- 1 Deg C +- 1 Deg C
Harmonic distortion (I THD & V THD) +-1% X X X X
Peak KW demand +-1% X X X X
Peak KVAr demand +-1% X X X X
Power Factor -1 - 0 - +1 0.01 X X X X
Rotation Speed + - 1 RPM
Metering Parameters
Comparison of ANSI features on Motor Protection Relays
ANSI Protection Functions M20 M81 M87 M88
12 Overspeed (2 set points)
14 Underspeed (2 set points)
21B Underimpedance
24 Flux control (V/Hz)
25 Synch-check
26/63 Thermostat / Buchholz
27/27S Undervoltage (L-L or L-N) 4 4 4
27D Positive sequence undervoltage 2 2 2
27R Remanent undervoltage 2 2 2
27TN/64G
2 64G
Third Harmonic Undervoltage &
100% stator ground fault
30 Annunciation
32P Directional active overpower 2 2 2
32Q/40/55 Directional reactive overpower 1 1 1
37 Phase undercurrent 1 1 1 1
37P Directional active overpower
38/49T
Temperature monitoring
8 RTD's 16 RTD's 16 RTD's 16 RTD's
40 Field loss underimpedance 1 1 1
46 Negative sequence unbalance 1 2 2 2
47 Negative sequence overvoltage 2 2 2
48/51LR/
14
Excessive starting time, locked rotor
1 1 1 1
49RMS Thermal overload 2 2 2 2
50/27 Inadvertant energization
50/51 Phase overcurrent 4 8 8 8
50BF Breaker failure 1 1 1
50V/51V Voltage restrained phase overcurrent
59 Overvoltage (L-L or L-N) 4 4 4
59N Neutral voltage displacement 2 2 2
60/60FL CT/VT supervision Y Y Y
64REF Restricted ground fault
66 Starts per hour 1 1 1 1
67 Directional phase overcurrent
67N/67NC Directional ground fault 2 2 2
68 Zone Selective Interlock (ZSI)
74 Trip circuit supervision
78PS Pole slip (loss of synch) 1 1 1
81H Overfrequency 2 2 2
81L Underfrequency 4 4 4
86 Latching, Lockout
87M Machine Differential 1
87T Transformer differential 1
94/69 CB_Control Logic
Note:
Optional Modules
(1) Protection functions with 2 groups of settings
The numbers in the matrix denote the number of trip points that can be configured
for this ANSI code.
8
50N/51N
50G/51G
Ground fault / Sensitive ground fault
4 8 8
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module
Metering Values Acc. M20 M81 M87 M88
Current 1,2,3 + - .5% X X X
+ -1% X
Current Peak Demand + - .5% X X X
+ -1% X
Current Demand + - .5% X X X
+ -1% X
Current Residual + -1% X X X X
Voltage L-N & L-L + - .5% X X X
Voltage Residual +-1% X X X
Neutral Point Voltage +-1% X X X
Voltage Neg. Sequence 1,2,3 + - 2% X X X
Voltage Pos. Sequence 1,2,3 + - 2% X X X
KW +-1% X X X
KVA +-1% X X X
KVAr +-1% X X X
KWh (Calculated) +-1% X X X
KVArh (Calculated) +-1% X X X
KWh (Pulse Counting) +-1%
KVArh (Pulse Counting) +-1%
KVAh +-1%
Frequency .01Hz X X X
Temperature + - 1 Deg +- 1 Deg C+- 1 Deg C +- 1 Deg C
Harmonic distortion (I THD & V THD) +-1% X X X
Peak KW demand +-1% X X X
Peak KVAr demand +-1% X X X
Power Factor -1 - 0 - +1 0.01 X X X
Rotation Speed + - 1 RPM
Metering Parameters
Comparison of ANSI features on Substation Protection Relays
ANSI Protection Functions S23 S40 S41 S42
21B Underimpedance
24 Flux control (V/Hz)
25 Synch-check
26/63 Thermostat / Buchholz
27/27S Undervoltage (L-L or L-N) 2 2 2
27D Positive sequence undervoltage
27R Remanent undervoltage
27TN/64G
2 64G
Third Harmonic Undervoltage & 100% stator
ground fault
30 Annunciation
32P Directional active overpower 1 1
32Q/40/55 Directional reactive overpower
37 Phase undercurrent
37P Directional active overpower
38/49T
Temperature monitoring
8 RTD's 16 RTD's 16 RTD's 16 RTD's
40 Field loss underimpedance
46 Negative sequence unbalance 1 2 2 2
47 Negative sequence overvoltage 1 1 1
49RMS Thermal overload
50/27 Inadvertant energization
50/51 Phase overcurrent 4 4 4 4
50BF Breaker failure 1 1 1 1
50V/51V Voltage restrained phase overcurrent
59 Overvoltage (L-L or L-N) 2 2 2
59N Neutral voltage displacement 2 2 2
60/60FL CT/VT supervision Y Y Y
64REF Restricted ground fault
66 Starts per hour
67 Directional phase overcurrent 2
67N/67NC Directional ground fault 2 2
68 Zone Selective Interlock (ZSI)
74 Trip circuit supervision
78PS Pole slip (loss of synch)
79 Recloser ( 4 shots )
81H Overfrequency 2 2 2
81L Underfrequency 4 4 4
81R Rate of change of frequency
86 Latching, Lockout
87M Machine Differential
87T Transformer differential
94/69 CB_Control Logic
Note:
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.
50N/51N
50G/51G
Ground fault / Sensitive ground fault
4 4 4 4
(4) With optional MCS025 synchro-check module
Comparison of ANSI features on Substation Protection Relays
S80 S82 S84 Metering Values Acc. S23 S40
Current 1,2,3 + - .5% X
+-1% X
Current Peak Demand + - .5% X
+-1% X
4 4 4 Current Demand + - .5% X
2 2 2 +-1% X
2 2 2 Current Residual +-1% X X
Voltage L-N & L-L + - .5% X
Voltage Residual +-1% X
2 2 Neutral Point Voltage +-1%
Voltage Neg. Sequence 1,2,3 + - 2% X
Voltage Pos. Sequence 1,2,3 + - 2% X
2 KW +-1% X
16 RTD's 16 RTD's 16 RTD's KVA +-1% X
KVAr +-1% X
2 2 2 KWh (Calculated) +-1% X
2 2 2 KVArh (Calculated) +-1% X
2 2 KWh (Pulse Counting) +-1% X
KVArh (Pulse Counting) +-1% X
8 8 8 KVAh +-1%
1 1 1 Frequency .01Hz X
Temperature + - 1 Deg
Harmonic distortion (I THD & V THD) +-1%
Peak KW demand +-1% X
4 4 4 Peak KVAr demand +-1% X
2 2 2 Power Factor -1 - 0 - +1 0.01 X
Y Y Y Rotation Speed + - 1 RPM
2 2
2 2
2 2 2
4 4 4
2
8
The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.
Metering Parameters
8 8
S41 S42 S80 S82 S84
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X X
X X
X X X X X
+- 1 Deg C +- 1 Deg C +- 1 Deg C
X X X
X X X X X
X X X X X
X X X X X
Metering Parameters
Comparison of ANSI features on Transformer Protection Relays
ANSI Protection Functions T23 T40 T42 T81 T82
25 Synch-check
26/63 Thermostat / Buchholz
27/27S Undervoltage (L-L or L-N) 2 2 4 4
27D Positive sequence undervoltage 2 2
27R Remanent undervoltage 2 2
30 Annunciation
32P Directional active overpower 2 2
32Q/40/55 Directional reactive overpower
37 Phase undercurrent
37P Directional active overpower
38/49T
Temperature monitoring
8 RTD's 16 RTD's 16 RTD's 16 RTD's 16 RTD's
40 Field loss underimpedance
46 Negative sequence unbalance 1 2 2 2 2
47 Negative sequence overvoltage 1 1 2 2
49RMS Thermal overload 2 2 2 2 2
50/27 Inadvertant energization
50/51 Phase overcurrent 4 4 4 8 8
50BF Breaker failure 1 1 1 1 1
50V/51V Voltage restrained phase overcurrent
59 Overvoltage (L-L or L-N) 2 2 4 4
59N Neutral voltage displacement 2 2 2 2
64REF Restricted ground fault 2 2
67 Directional phase overcurrent 2 2
67N/67NC Directional ground fault 2 2 2
68 Zone Selective Interlock (ZSI)
74 Trip circuit supervision
81H Overfrequency 2 2 2 2
81L Underfrequency 4 4 4 4
81R Rate of change of frequency
86 Latching, Lockout
87M Machine Differential
87T Transformer differential
94/69 CB_Control Logic
Note:
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module
50N/51N
50G/51G
Ground fault / Sensitive ground fault
4 4
The numbers in the matrix denote the number of trip points that can be configured for this
ANSI code.
8 8 4
Metering Values Acc. T23 T40 T42 T81 T82
Current 1,2,3 + - .5% X X X X
+-1% X
Current Peak Demand + - .5% X X X X
+-1% X
Current Demand + - .5% X X X X
+-1% X
Current Residual +-1% X X X X X
Voltage L-N & L-L + - .5% X X X X
Voltage Residual +-1% X X X X
Neutral Point Voltage +-1% X X
Voltage Neg. Sequence 1,2,3 + - 2% X X X X
Voltage Pos. Sequence 1,2,3 + - 2% X X X X
KW +-1% X X X X
KVA +-1% X X X X
KVAr +-1% X X X X
KWh (Calculated) +-1% X X X X
KVArh (Calculated) +-1% X X X X
KWh (Pulse Counting) +-1% X X
KVArh (Pulse Counting) +-1% X X
KVAh +-1%
Frequency .01Hz X X X X
Temperature + - 1 Deg +- 1 Deg C +- 1 Deg C
Harmonic distortion (I THD & V THD) +-1% X X
Peak KW demand +-1% X X X X
Peak KVAr demand +-1% X X X X
Power Factor -1 - 0 - +1 0.01 X X X X
Rotation Speed + - 1 RPM
Metering Parameters