Model Number: SQ1 S23 B 1 O 0 A 0 A 0 Cost of Sepam Unit: $1,483.00
Device Type Provides Protection For: Includes Metering Values: Display Type Current Option Digital I/O Option Communications Option RTD Option (Not available on substation or busbar models) Analog Outputs Description: Logipam Programming (Series 80 only) Sync Check Option (ANSI - 25, Series 80 Only) * denotes a default component You have selected a (S23) 20 Series Substation Protection Relay (24-250Vdc & 120-240Vac), Basic display included in base unit, (CCA634) 1/5A CT inputs (3PH and Ground/Residual or ZSCT), No I/O module, No communications card, No temperature sensor inputs (RTD module), No Analog outputs, No Logipam programming ability, No Synch Check Module. Component Numbers SEPAM PRICING GUIDE S Q 1 R e l a y
B a s e
M o d e l D i s p l a y C u r r e n t I / O C o m s R T D ' s A n a l o g
O u t L o g i p a m S y n c h
C h e c k Relay Base Model Competition Example SQ1 T87 A 1 J 1 A 1 A 0 C86 C86 Competition S23 S23 Competition S40 S40 Competition S42 S42 Competition S43 S43 S80 S80 Competition S82 S82 Competition S84 S84 Competition B21 B21 B22 B22 Competition B80 B80 B83 B83 G40 G40 Competition G82 G82 Competition G87 G87 Competition G88 G88 Competition M20 M20 Competition M41 M41 Competition M81 M81 Competition M87 M87 Competition M88 M88 Competition T23 T23 Competition T40 T40 Competition T42 T42 Competition T81 T81 T82 T82 Competition T87 T87 Competition Display A B P MimicBus R DSM303 (Series 20 & 40 Only) C DSM303 (Series 80 Only) Current 1 CCA634 2 CCA630 3 CCA671 I/O for models 20 & 40 (will not work with model 80) O without A MES114 B MES114E C MES114F I/O for models 80 Max. 3 per base unit (will not work with models 20 & 40) O without No I/O D MES120 14 Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only) E MES120 28 Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only) F MES120 42 Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only) G MES120G 14 inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only) H MES120G 28 inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only) I MES120G 42 inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only) J MES120H 14 inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only) K MES120H 28 inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only) L MES120H 42 inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only) Communications 0 without 1 ACE959 2 ACE969TP2 3 ACE969FO2 4 ECI850 5 ACE850 RTD used only for the following applications: Motor, Generator, Capacitor or Transformer A without B MET1482 (One Module) C MET1482 (Two Modules) Analog Output 0 without 1 MSA141 Series 80 Options A without B SFT080 0 without 1 MCS025 SQ1 T87 A 1 J 1 A 0 A 0 Accessories - Not to be included in the relay part number RTM 3090RTM317 CSH30 CSH30 CSCT120 CSH120 CSCT200 CSH200 EGX100 EGX100 EGX400 EGX400 ECI850 ECI850 ACE850 ACE850 ABL8RPS24030 ABL8RPS24050 Software SFT2841KIT SFT2841KIT SFTKIT SEPAM PRICING GUIDE Competition Description List Price Capacitor 80 Series Capacitor Relay, 24-250Vdc $3,825.00 Compare Substation Relays 20 Series Substation Protection Relay, 24-250Vdc & 120-240Vac $1,483.00 40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac $2,713.00 40 Series Substation, 24-250Vdc & 120-240Vac Applincation: Substation - S40A + Directional 67, 67N protection. Parallel main protection. ZSI and ATS $3,559.00 40 Series Substation, 24-250Vdc & 120-240Vac $2,330.00 80 Series Substation Protection Relay, 24-250Vdc $3,570.00 80 Series Substation Protection Relay, 24-250Vdc $3,880.00 80 Series Substation Protection Relay, 24-250Vdc $4,480.00 Compare Busbar Relays 20 series Busbar Protection Relay 24-250Vdc & 120-240Vac $1,953.00 20 series Busbar Protection Relay 24-250Vdc & 120-240Vac $2,266.00 80 Series Busbar Protection Relay, 24-250Vdc $3,750.00 80 Series Busbar Protection Relay, 24-250Vdc $3,950.00 Compare Generator Relays 40 Series Generator Protection relay, 24-250Vdc & 120-240Vac $3,609.00 80 Series Generator Protection Relay, 24-250Vdc $3,870.00 80 Series Generator Protection Relay, 24-250Vdc $4,220.00 80 Series Generator Protection Relay, 24-250Vdc $5,222.00 Compare Motor Relays 20 series Motor Protection Relay 24-250Vdc & 120-240Vac $2,009.00 40 Series Motor Protection Relay, 24-250Vdc & 120-240Vac, $3,129.00 80 Series Motor Protection Relay, 24-250Vdc, $3,240.00 80 Series Motor Protection Relay, 24-250Vdc, $3,550.00 80 Series Motor Protection Relay, 24-250Vdc, $3,840.00 Compare Transformer Relays 20 series Transformer Relay 24-250Vdc & 120-240Vac $1,957.00 40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac $2,961.00 40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac $3,808.00 80 Series Transformer Protection Relay, 24-250Vdc $3,830.00 80 Series Transformer Protection Relay, 24-250Vdc $4,130.00 80 Series Transformer Protection Relay, 24-250Vdc $4,580.00 Advanced display included in base unit $300.00 Standard LED Display included in base uniit $0.00 MimicBus Graphical Display (for series 80 only) $450.00 Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 20/40 AMT840 (Replaces integrated display) $540.00 Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 80 AMT880 (Replaces integrated display) $654.00 5A input standard on relays for current measurement, not included on voltage only relays $0.00 Only for use with CSH120, 200 ground fault sensor, and CSH30 $0.00 25/3750A LPCT Connector for All SEPAM Series Note: Used with Motorpact or other medium voltage starter, includes CSH30 $531.00 I/O for models 20 & 40 (will not work with model 80) No I/O $0.00 10 Inputs + 4 Outputs Module, 24-48Vdc and 120-250V ac Capacitor Trip application $616.00 10 Inputs + 4 Outputs Module, 110-125 Vdc, 110Vac $595.00 10 Inputs + 4 Outputs Module, 220-250Vdc, 220-240Vac $785.00 I/O for models 80 Max. 3 per base unit (will not work with models 20 & 40) $0.00 14 Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only) $770.00 28 Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only) $1,540.00 42 Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only) $2,310.00 14 inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $770.00 28 inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $1,540.00 42 inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only) $2,310.00 14 inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $770.00 28 inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $1,540.00 42 inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only) $2,310.00 No communications card $0.00 1 RS 485 Modbus Port (12 or 24 VDC Power) included with all relays $398.00 (2)RS485 2wire ports, Port 1 Modbus, Port 2 Modbus, DNP3 or IEC 60870 (requires 110- 240VAC/ 24-250DC ext. power). Includes CCA612 CAT5 cable. $275.00 (1) RS485 2wire Modbus + (1) Fiber Modbus, DNP3 or IEC 60870 (requires110-240VAC/ 24- 250DC). Includes CCA612 CAT5 cable. $771.00 1 x RS485 IEC 61850 protocol port $1,000.00 61850 + Modbus TCPIP Ethernet Module (not currently availible) RTD used only for the following applications: Motor, Generator, Capacitor or Transformer No RTD module $0.00 8 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5 cable. Note: Series 20, 40 & 80 $695.00 16 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5 cable. Note: Series 40 & 80 only $1,390.00 No Analog Output $0.00 1 Analog output module, software selectable 0/10mA, 0/20mA or 4/20mA (includes CCA77X cable) $631.00 No Logipam $0.00 Logipam firmware (PLC base) $250.00 No Synch Check Module $0.00 Sync-check Module_ANSI-25 for model 80 only (includes ATM840 Surface Mount Plate) $1,540.00 Accessories - Not to be included in the relay part number Ride Through Module Recommented for AC control voltage application (for all series 20, 40 and 80) $574.00 Interposing CT for Residual ground current input, use with LPCT $116.00 Ground sensor CT - 120mm window (zsct) $235.00 Ground sensor CT - 200mm window (zsct) $378.00 Ethernet Gateway; RS-485/RS232, 10/100 BASE TX Transparent ready $950.00 Ethernet Gateway;(2) RS-485 serial ports,10/100T,100FX (Fiber),8 imbedded web pages, Modbus Protocol $2,460.00 1 Ethernet port 10/100 base T (Protocol: Modbus or IEC 61850) (Requires ACE Com Card) $850.00 2 Ethernet ports 10/100 base T Only for Series 80 (Protocol: Modbus or IEC 61850) does not require ACE Com Card $850.00 Power Supply: Input 110-480VAC, Output 24VDC 3A_for upto 15 comm module $180.00 Power Supply: Input 110-480VAC, Output 24VDC 5A_for upto 25 comm module $240.00 Relay Programming Software includes CD w/relay connector cable & USB / Serial cable, necessary for programming and troubleshooting relays) $275.00 Relay Programming Software includes SFT 2841 CD & SFT 2885 Logipam programming CD w/relay connector cable & USB / Serial cable Note: must have Logipam option on a series 80 relay to use Logipam programming software $495.00 Note: SFT2841 to be a free download (like ION Setup). The kit includes the program on a disk and the connection cables. Kit price may be reduced Competition Description List Price General Selection Guide Protection Functions Applications Base Specific Substation Bus Transformer Motor Current Protections S20 T20 M20 Breaker Failure S23 T23 Voltage and Frequency Protection B21 disconnection by "rate of change of frequency" B22 Base Specific Substation Bus Transformer Motor Current, Voltage and Frequency Protection S40 T40 directional ground fault S41 M41 directional ground fault and phase overcurrent S42 T42 Base Specific Substation Bus Transformer Motor Current, Voltage and Frequency Protection S80 B80 directional ground fault S81 T81 M81 directional ground fault and phase overcurrent S82 T82 disconnection by "rate of change of frequency" S84 Current, Voltage and Frequency Protection Transformer and transformer-machine unit differential T87 M88 Machine Differential M87 Current, Voltage and Frequency Protection Voltage and frequentcy protection for two sets of bus B83 Current, Voltage and Frequency Protection Capacitor bank unbalance Generator Capacitor Generator Capacitor G40 Generator Capacitor G82 G88 G87 C86 SEPAM Knowledgebase and FAQ's SQ1B21A SQ1G40A SQ1C86A SQ1M20A SQ1M41A SQ1G82A SQ1S23A SQ1S40A SQ1G87A SQ1T23A SQ1S42A SQ1G88A SQ1T40A SQ1M81A SQ1T42A SQ1M87A SQ1M88A SQ1S80A SQ1S82A SQ1S84A SQ1T82A SQ1T87A SEPAM Links: Substation - (S40A + Directional 67, 67N) protection. Parallel main protection, ZSI and ATS Substation - Current, protection of low- capacitance Feeders / Mains in impedance grounded or solidly grounded neutral systems. Capacitor feeder bank (delta connection) Transformer - Current and voltage protection. Current Protection Only Motor, FVNR, FVR 100-1500HP- Current protection without voltage monitoring Series 20 control voltage 24-250V DC, or 110-220V AC (for AC use RTM #3090RTM317) Series 40 control voltage 24-250V DC, or 110-220V AC (for AC use RTM #3090RTM317) SEPAM Tech Library; docs, curves and specifications SEPAM Software downloads Transformer - (T82 + 87T). Current and voltage + Directional. Parallel transformer main & differential protection Substation - (S80A + Directional 67, 67N, 27,59, 59N, 81L, 81R, 32P, 37P). Protection of main or tie CB with load shedding, ZSI & ATS Transformer - Current protection without voltage monitoring Current Protection Only Transformer - Current and voltage + Directional. Parallel transformer main protection Motor feeder - Current protection with voltage monitoring. For motor self balance Diff "87M" add Basler BE3-50/51. Motor - (M81 + 87M)Current protection with voltage monitoring and motor self balance Diff "87M" or full percentage diff Substation - Current & Voltage, protection of low-capacitance Feeders / Mains in impedance grounded or solidly grounded neutral systems Substation - (S80A + Directional 67, 67N). Protection of main or tie CB with load shedding, ZSI & ATS Series 80 control voltage 24-250V DC, for 110-220V AC (use RTM #3090RTM317) Motor-transformer unit differential protection Transformer - (T40A + Directional 67, 67N). Current and voltage + Directional. Parallel transformer main protection SEPAM Relays Series 80 Motor, FVNR, RVAT, FVR, FV2S, FR 500- 5000HP - Current protection with voltage monitoring. For motor self-balance Diff "87M" add Basler BE3-50/51. Substation - Current & Voltage, protection of low-capacitance Feeders / Mains in impedance grounded or solidly grounded neutral systems. Capacitor bank (delta connection) Capacitor bank - Double-wye connected protection with 1 to 4 steps Generator Protection coupled to other generators or to a network Generator - Current protection with voltage monitoring and gen self-balance Diff "87M" or full percentage diff Generator-transformer unit differential protection Voltage/Frq Protection Only Current Protection Only SEPAM Relays Series 20 SEPAM Relays Series 40 Generator - Current, Voltage and Frequency Protection of a separate generator. For Gen-self-balance Diff "87M" add Basler BE3-50/51. Bus - Voltage and Frequency protection and ATS ANSI Protection Functions B21 B22 B80 B83 25 Synch-check 27 Undervoltage (L-L) 2/1 (3) 2/1 (3) 4 4 27D Positive sequence undervoltage 2 2 2 2 27R Remanent undervoltage 1 1 2 2 27S Undervoltage (L-N) 30 Annunciation 46 Negative sequence / unbalance 2 2 47 Negative Sequence Overvoltage 2 2 50/51 Phase Overcurrent 8 8 50BF Breaker Failure 1 1 50N/51N Ground Fault 8 8 50G/51G Sensitive Ground Fault 59 Overvoltage (L-L or L-N) 2 2 4 4 59N Neutral voltage displacement 2 2 2 2 81H Overfrequency 1 1 2 2 81L Underfrequency 2 2 4 4 81R Rate of change of frequency (df/dt) _ (SQ1B22A only_use with Gen application) 1 86 Latching, Lockout 94/69 CB_Control Logic Note: Optional The Difference between B80 and B83? (1) Protection functions with 2 groups of settings B83: monitors Line and Bus voltage (2) With optional MSC025 Synch Check Module (2 sets of VT's) (3) 2 Undervoltage (L-L) and 1 undervoltage (L-N) Comparison of ANSI features on Busbar Protection Relays The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. Metering Values Acc. B21 B22 B80 B83 Current 1,2,3 + - .5% X X Current Peak Demand + - .5% X X Current Demand + - .5% X X Current Residual +-1% X X Voltage L-N & L-L + - .5% X X +-1% X X Voltage Residual +-1% X X X X Neutral Point Voltage +-1% X X Voltage Neg. Sequence 1,2,3 + - 2% X X Voltage Pos. Sequence 1,2,3 + - 2% X X X X KW +-1% X X KVA +-1% X X KVAr +-1% X X KWh (Calculated) +-1% X X X X KVArh (Calculated) +-1% X X KWh (Pulse Counting) +-1% KVArh (Pulse Counting) +-1% KVAh +-1% Frequency .01Hz X X X X Temperature + - 1 Deg +- 1 Deg C +- 1 Deg C Harmonic distortion (I THD & V THD) +-1% X X Peak KW demand +-1% X X Peak KVAr demand +-1% X X Power Factor -1 - 0 - +1 0.01 X X Rotation Speed + - 1 RPM Metering Parameters Comparison of ANSI features on Generator Protection Relays ANSI Protection Functions G40 G82 G87 G88 12 Overspeed (2 set points) 14 Underspeed (2 set points) 21B Underimpedance 1 1 1 24 Flux control (V/Hz) 2 2 2 25 Synch-check 26/63 Thermostat / Buchholz 27/27S Undervoltage (L-L or L-N) 2 4 4 4 27D Positive sequence undervoltage 2 2 2 27R Remanent undervoltage 2 2 2 27TN/64G2 64G Third Harmonic Undervoltage & 100% stator ground fault 2 2 2 30 Annunciation 32P Directional active overpower 1 2 2 2 32Q/40/55 Directional reactive overpower 1 1 1 1 37P Directional active overpower 2 38/49T Temperature monitoring 8 RTD's 16 RTD's 16 RTD's 16 RTD's 40 Field loss underimpedance 1 1 1 46 Negative sequence unbalance 2 2 2 2 47 Negative sequence overvoltage 1 2 2 2 49RMS Thermal overload 2 2 2 2 50/27 Inadvertant energization 1 1 50/51 Phase overcurrent 4 8 8 8 50BF Breaker failure 1 1 1 1 50V/51V Voltage restrained phase overcurrent 1 2 2 2 59 Overvoltage (L-L or L-N) 2 4 4 4 59N Neutral voltage displacement 2 2 2 2 60/60FL CT/VT supervision Y Y Y Y 64REF Restricted ground fault 2 2 67 Directional phase overcurrent 2 2 2 67N/67NC Directional ground fault 2 2 2 68 Zone Selective Interlock (ZSI) 74 Trip circuit supervision 78PS Pole slip (loss of synch) 1 1 1 81H Overfrequency 2 2 2 2 81L Underfrequency 4 4 4 4 86 Latching, Lockout 87M Machine Differential 1 87T Transformer differential 1 94/69 CB_Control Logic Note: Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. 8 50N/51N 50G/51G Ground fault / Sensitive ground fault 4 8 8 Metering Values Accuracy G40 G82 G87 G88 Current 1,2,3 + - .5% X X X X Current Peak Demand + - .5% X X X X Current Demand + - .5% X X X X Current Residual +-1% X X X X Voltage L-N & L-L + - .5% X X X X Voltage Residual +-1% X X X X Neutral Point Voltage +-1% X X X Voltage Neg. Sequence 1,2,3 + - 2% X X X X Voltage Pos. Sequence 1,2,3 + - 2% X X X X KW +-1% X X X X KVA +-1% X X X X KVAr +-1% X X X X KWh (Calculated) +-1% Op X X X KVArh (Calculated) +-1% Op X X X KWh (Pulse Counting) +-1% Op KVArh (Pulse Counting) +-1% Op KVAh +-1% Frequency .01Hz X X X X Temperature + - 1 Deg Op +- 1 Deg C +- 1 Deg C +- 1 Deg C Harmonic distortion (I THD & V THD) +-1% X X X X Peak KW demand +-1% X X X X Peak KVAr demand +-1% X X X X Power Factor -1 - 0 - +1 0.01 X X X X Rotation Speed + - 1 RPM Metering Parameters Comparison of ANSI features on Motor Protection Relays ANSI Protection Functions M20 M81 M87 M88 12 Overspeed (2 set points) 14 Underspeed (2 set points) 21B Underimpedance 24 Flux control (V/Hz) 25 Synch-check 26/63 Thermostat / Buchholz 27/27S Undervoltage (L-L or L-N) 4 4 4 27D Positive sequence undervoltage 2 2 2 27R Remanent undervoltage 2 2 2 27TN/64G 2 64G Third Harmonic Undervoltage & 100% stator ground fault 30 Annunciation 32P Directional active overpower 2 2 2 32Q/40/55 Directional reactive overpower 1 1 1 37 Phase undercurrent 1 1 1 1 37P Directional active overpower 38/49T Temperature monitoring 8 RTD's 16 RTD's 16 RTD's 16 RTD's 40 Field loss underimpedance 1 1 1 46 Negative sequence unbalance 1 2 2 2 47 Negative sequence overvoltage 2 2 2 48/51LR/ 14 Excessive starting time, locked rotor 1 1 1 1 49RMS Thermal overload 2 2 2 2 50/27 Inadvertant energization 50/51 Phase overcurrent 4 8 8 8 50BF Breaker failure 1 1 1 50V/51V Voltage restrained phase overcurrent 59 Overvoltage (L-L or L-N) 4 4 4 59N Neutral voltage displacement 2 2 2 60/60FL CT/VT supervision Y Y Y 64REF Restricted ground fault 66 Starts per hour 1 1 1 1 67 Directional phase overcurrent 67N/67NC Directional ground fault 2 2 2 68 Zone Selective Interlock (ZSI) 74 Trip circuit supervision 78PS Pole slip (loss of synch) 1 1 1 81H Overfrequency 2 2 2 81L Underfrequency 4 4 4 86 Latching, Lockout 87M Machine Differential 1 87T Transformer differential 1 94/69 CB_Control Logic Note: Optional Modules (1) Protection functions with 2 groups of settings The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. 8 50N/51N 50G/51G Ground fault / Sensitive ground fault 4 8 8 (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module Metering Values Acc. M20 M81 M87 M88 Current 1,2,3 + - .5% X X X + -1% X Current Peak Demand + - .5% X X X + -1% X Current Demand + - .5% X X X + -1% X Current Residual + -1% X X X X Voltage L-N & L-L + - .5% X X X Voltage Residual +-1% X X X Neutral Point Voltage +-1% X X X Voltage Neg. Sequence 1,2,3 + - 2% X X X Voltage Pos. Sequence 1,2,3 + - 2% X X X KW +-1% X X X KVA +-1% X X X KVAr +-1% X X X KWh (Calculated) +-1% X X X KVArh (Calculated) +-1% X X X KWh (Pulse Counting) +-1% KVArh (Pulse Counting) +-1% KVAh +-1% Frequency .01Hz X X X Temperature + - 1 Deg +- 1 Deg C+- 1 Deg C +- 1 Deg C Harmonic distortion (I THD & V THD) +-1% X X X Peak KW demand +-1% X X X Peak KVAr demand +-1% X X X Power Factor -1 - 0 - +1 0.01 X X X Rotation Speed + - 1 RPM Metering Parameters Comparison of ANSI features on Substation Protection Relays ANSI Protection Functions S23 S40 S41 S42 21B Underimpedance 24 Flux control (V/Hz) 25 Synch-check 26/63 Thermostat / Buchholz 27/27S Undervoltage (L-L or L-N) 2 2 2 27D Positive sequence undervoltage 27R Remanent undervoltage 27TN/64G 2 64G Third Harmonic Undervoltage & 100% stator ground fault 30 Annunciation 32P Directional active overpower 1 1 32Q/40/55 Directional reactive overpower 37 Phase undercurrent 37P Directional active overpower 38/49T Temperature monitoring 8 RTD's 16 RTD's 16 RTD's 16 RTD's 40 Field loss underimpedance 46 Negative sequence unbalance 1 2 2 2 47 Negative sequence overvoltage 1 1 1 49RMS Thermal overload 50/27 Inadvertant energization 50/51 Phase overcurrent 4 4 4 4 50BF Breaker failure 1 1 1 1 50V/51V Voltage restrained phase overcurrent 59 Overvoltage (L-L or L-N) 2 2 2 59N Neutral voltage displacement 2 2 2 60/60FL CT/VT supervision Y Y Y 64REF Restricted ground fault 66 Starts per hour 67 Directional phase overcurrent 2 67N/67NC Directional ground fault 2 2 68 Zone Selective Interlock (ZSI) 74 Trip circuit supervision 78PS Pole slip (loss of synch) 79 Recloser ( 4 shots ) 81H Overfrequency 2 2 2 81L Underfrequency 4 4 4 81R Rate of change of frequency 86 Latching, Lockout 87M Machine Differential 87T Transformer differential 94/69 CB_Control Logic Note: Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. 50N/51N 50G/51G Ground fault / Sensitive ground fault 4 4 4 4 (4) With optional MCS025 synchro-check module Comparison of ANSI features on Substation Protection Relays S80 S82 S84 Metering Values Acc. S23 S40 Current 1,2,3 + - .5% X +-1% X Current Peak Demand + - .5% X +-1% X 4 4 4 Current Demand + - .5% X 2 2 2 +-1% X 2 2 2 Current Residual +-1% X X Voltage L-N & L-L + - .5% X Voltage Residual +-1% X 2 2 Neutral Point Voltage +-1% Voltage Neg. Sequence 1,2,3 + - 2% X Voltage Pos. Sequence 1,2,3 + - 2% X 2 KW +-1% X 16 RTD's 16 RTD's 16 RTD's KVA +-1% X KVAr +-1% X 2 2 2 KWh (Calculated) +-1% X 2 2 2 KVArh (Calculated) +-1% X 2 2 KWh (Pulse Counting) +-1% X KVArh (Pulse Counting) +-1% X 8 8 8 KVAh +-1% 1 1 1 Frequency .01Hz X Temperature + - 1 Deg Harmonic distortion (I THD & V THD) +-1% Peak KW demand +-1% X 4 4 4 Peak KVAr demand +-1% X 2 2 2 Power Factor -1 - 0 - +1 0.01 X Y Y Y Rotation Speed + - 1 RPM 2 2 2 2 2 2 2 4 4 4 2 8 The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. Metering Parameters 8 8 S41 S42 S80 S82 S84 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X +- 1 Deg C +- 1 Deg C +- 1 Deg C X X X X X X X X X X X X X X X X X X Metering Parameters Comparison of ANSI features on Transformer Protection Relays ANSI Protection Functions T23 T40 T42 T81 T82 25 Synch-check 26/63 Thermostat / Buchholz 27/27S Undervoltage (L-L or L-N) 2 2 4 4 27D Positive sequence undervoltage 2 2 27R Remanent undervoltage 2 2 30 Annunciation 32P Directional active overpower 2 2 32Q/40/55 Directional reactive overpower 37 Phase undercurrent 37P Directional active overpower 38/49T Temperature monitoring 8 RTD's 16 RTD's 16 RTD's 16 RTD's 16 RTD's 40 Field loss underimpedance 46 Negative sequence unbalance 1 2 2 2 2 47 Negative sequence overvoltage 1 1 2 2 49RMS Thermal overload 2 2 2 2 2 50/27 Inadvertant energization 50/51 Phase overcurrent 4 4 4 8 8 50BF Breaker failure 1 1 1 1 1 50V/51V Voltage restrained phase overcurrent 59 Overvoltage (L-L or L-N) 2 2 4 4 59N Neutral voltage displacement 2 2 2 2 64REF Restricted ground fault 2 2 67 Directional phase overcurrent 2 2 67N/67NC Directional ground fault 2 2 2 68 Zone Selective Interlock (ZSI) 74 Trip circuit supervision 81H Overfrequency 2 2 2 2 81L Underfrequency 4 4 4 4 81R Rate of change of frequency 86 Latching, Lockout 87M Machine Differential 87T Transformer differential 94/69 CB_Control Logic Note: Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module 50N/51N 50G/51G Ground fault / Sensitive ground fault 4 4 The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. 8 8 4 Metering Values Acc. T23 T40 T42 T81 T82 Current 1,2,3 + - .5% X X X X +-1% X Current Peak Demand + - .5% X X X X +-1% X Current Demand + - .5% X X X X +-1% X Current Residual +-1% X X X X X Voltage L-N & L-L + - .5% X X X X Voltage Residual +-1% X X X X Neutral Point Voltage +-1% X X Voltage Neg. Sequence 1,2,3 + - 2% X X X X Voltage Pos. Sequence 1,2,3 + - 2% X X X X KW +-1% X X X X KVA +-1% X X X X KVAr +-1% X X X X KWh (Calculated) +-1% X X X X KVArh (Calculated) +-1% X X X X KWh (Pulse Counting) +-1% X X KVArh (Pulse Counting) +-1% X X KVAh +-1% Frequency .01Hz X X X X Temperature + - 1 Deg +- 1 Deg C +- 1 Deg C Harmonic distortion (I THD & V THD) +-1% X X Peak KW demand +-1% X X X X Peak KVAr demand +-1% X X X X Power Factor -1 - 0 - +1 0.01 X X X X Rotation Speed + - 1 RPM Metering Parameters