Vous êtes sur la page 1sur 8

SKF LAGG 50A

or LAGG 180A
Air-driven Grease Pumps

Instructions for use

Safety recommendations

The operating instructions should always be followed.


NEVER point the grease gun at people or animals.
Assure that the pressure in the air inlet hose is not above 8 bars.
Replace any damaged hoses immediately.
After use always disconnect the air inlet hose and release
pressure from the grease pump by operating the grease gun.
Protect all hoses against damage and excessive heat.
Before maintenance always remove the air pressure from the
grease pump (disconnect the air inlet hose and release pressure
from the filler pump by operating the grease gun).
Inspection and maintenance work may only be done by qualified
personnel.

SKF LAGG 50A & 180A

1. Application
The SKF LAGG 50A and LAGG 180A are air operated grease pumps
suitable for 50 or 180 kg drums with any greases of an NLGI class
0, 1 or 2.

2. Description
The pneumatically operated grease pump is fully automatic. By
operating the grease gun handle the grease will automatically be
discharged. As soon as the handle is released the grease discharge is
automatically stopped.
Note: It is recommended to include a pressure valve in the air inlet. This
will increase the working life of the grease pump mechanism.

3. Technical data
LAGG 50A

LAGG 180A

Maximum pressure air inlet

8 bars (120 psi)

8 bars (120 psi)

Minimum pressure air inlet

3 bars (40 psi)

3 bars (40 psi)

Pressure ratio

1:55

1:55

Maximum output pressure


(with 8 bars air inlet pressure)

425 bars (6.160 psi)

425 bars (6.160 psi)

Suitable grease

NLGI 0, 1 or 2

NLGI 0, 1 or 2

- max. inside height

350 - 385 mm
(13,8 - 15,2 in)
860 mm (33,9 in)

550 - 590 mm
(21,7 - 23,2 in)
860 mm (33,9 in)

Air quick connection nipple

CEJN 10-320-5152

CEJN 10-320-5152

Length of hose

3,5 m (11 ft 5 in)

3,5 m (11 ft 5 in)

Weight

15 kg (33 lb)

26 kg (57 lb)

Suitable drum dimensions:


- inside diameter

4. Replacement parts
Replacement parts available on request.

SKF LAGG 50A & 180A

5. Operating instructions
5.1 Before use

1.
2.

Remove the lid of the grease drum.


Place the follower plate on top of the grease in the drum. Push the
follower plate down until grease is visible through the centre
opening of the plate.

3.
4.

Fit the cover plate on top of the drum.


Tighten the three butterfly screws to secure the top to the drum.

Note: Assure that the cover plate is centred and securely fixed to the
drum.

SKF LAGG 50A & 180A

5.
6.

Insert the piston rod of the pump mechanism through the cover
plate and the follower plate. Assure that the piston rod penetrates
all the way to the bottom of the drum or until it hits the cover plate.
Secure the piston rod to the cover plate by tightening the
clamp-screw.

7.
8.
9.

Connect the grease gun hose to the grease pump.


Check that all the connections are securely fixed.
Check that none of the hoses are damaged and replace any
damaged hoses immediately.
10. Connect the air inlet hose to the quick connection nipple on the
grease pump. Check that the air inlet pressure is not above 8 bars
(120 psi).

SKF LAGG 50A & 180A

11. Open the grease gun handle until grease is discharged from the
gun. All the air has now been removed from the grease gun.
The grease pump is now ready for use.
Grease is discharged from the grease pump by operating the grease
gun handle.
5.2 After use

1.
2.
3.
4.

Disconnect the air inlet hose.


Release the pressure from the grease pump by operating the
grease gun handle.
Transfer any possible grease residence to the next grease drum.
Assure that after use the grease is discharged in an
environmentally friendly way.

SKF LAGG 50A & 180A

SKF LAGG 50A & 180A

In line with our policy of continuous development of


our products we reserve the right to alter any part of
the above specification without prior notice.

Copyright SKF 2001/01

www.skf.com